Cost-effective Digital Sampling Power Analyzer. Digital Power Meter

Size: px
Start display at page:

Download "Cost-effective Digital Sampling Power Analyzer. Digital Power Meter"

Transcription

1 Costeffective Digital Sampling Power Analyzer Digital Power Meter WT2/WT3 Fundamental accuracy of.2% (WT2) or.25% (WT3) DC measurement, Hz to 5 khz frequency band Compact design (halfrack size) MAX hold function (WT2) Builtin 5 ma range for measuring small current (WT2) Builtin harmonic analysis function (optional) Comparator function (optional) for GO/NOGO judgement User calibration (by remote communication or manually) Sensor input(optional) for use with external current clamps and shunts Bulletin 25346E

2 Measure anything from low standby power to rated power with a single WT2. Builtin wide input range of 5 ma to 2 A with WT2 Features of WT2 Builtin small input range from 5 ma The WT2 s 5 ma range enables currents as low as 25µA to be measured, making it ideal for measuring small currents of intermittently controlled equipment. Furthermore, the wide current range extends from 5 ma to 2 A, so a single WT2 can measure everything from the standby power to the rated power of a device. MAX hold function The maximum display values for voltage and current peak values, voltage and current rms values, active power, apparent power, or reactive power are held on the LED display. This is handy for evaluating inrush currents or measuring the maximum consumed power resulting from load fluctuations. Integrating time of one second to, hours The integrating time can be set from one second to, hours in units of one second, thus allowing flexible analysis of a short time or within a specific period. Display of average active power Intermittently controlled equipment intended for reducing power consumption has periods of activity and inactivity (standby), so the power value changes significantly each time the display is updated. The WT2 can display the average active power determined from the integrated power, so the integrated power of intermittently controlled equipment can be measured. Average active power (W) Integrated power (Wh)/Integrated elapsed time (hour) Power Instantaneous power Average active power Time Example of current measurement error tolerance of WT2 (5 ma/ 5 ma ranges) 2 Tolerance relative to reading (% of reading) ma range 5 ma range. Input level relative to set range (% of range)

3 Basic Power Measurement Functions & Optional Functions for Broader Applications Outstanding Functionality and Portability Features of WT2/WT3 DC Measurements The WT2 and WT3 can measure DC, and so halfwave rectified signals containing DC components or intermittent signals can be measured without considering the input signals. Compact Design, Large LED Display The ultracompact case design allows two models to be rackmounted side by side. And the low weight of just 3 kg for the WT2 or 5 kg for the WT3 makes light work when using the devices in the field. The new large LED display also greatly improves readability. Four Arithmetic Operations and Crest Factor Function Voltage and Current Crest Factor, and the results of four arithmetic operations from the measured values of Displays A & B can be displayed on Display C. The WT3 can also calculate Efficiency. Storage/Recalling of Measured Data and Setting Information Measured data can now be stored while onsite thanks to an internal memory. Data of about 6 measurements can be stored in the WT2 singleinputelement model, or data of about 2 measurements in the WT3 threeinputelement model. Stored data can also be read from the memory and displayed on the LED display. And up to four setting patterns can be stored. Bidirectional Integration function The WT2 and WT3 are perfect for evaluating batteryoperated equipment and motordriven machines that regenerate power. This function integrates current or power in both the positive and negative directions independently. Harmonic Analysis Function (Optional) Despite their low cost, the WT2/WT3 can be equipped with a harmonic analysis function for calculating and displaying voltage, current, active power, harmonic contents ratio, and phase angle relative to the fundamental signal up to the 5th order, making these power meters ideal for power supplies. Current Sensor Input (Optional) The WT2/WT3 can be equipped with either a shunt input range (5//2 mv) or sensor input voltage range (2.5/5/ V). The use of a current clamp allows current measurements without disconnecting the wiring of the power circuit. Fourchannel Comparator & D/A Output (Optional) 4channel D/A outputs can be included in addition to the 4 sets of relay contact outputs (normally opened and normally closed contacts in pairs) used to judge GO/NOGO in production or inspection lines. Comparison between WT2 and WT3 Number of inputs Fundamental voltage/current accuracy Fundamental power accuracy Voltage range Current range WT2 Single input element ±(.5% of rdg +.% of rng) ±(.2% of rdg +.% of rng) 5/3/6/5/3/6 [V] 5//2/5//2[mA].5//2/5//2 [A] Available DC, Hz to 5 khz Standard Standard Standard sec. to, hr (units of sec.) Available (optional) WT3 Two or three input elements ±(.2% of rdg +.% of rng) ±(.25% of rdg +.% of rng) 5/3/6/5/3/6 [V].5//2/5//2 [A] DC measurement Frequency range Peak measuring function MAX hold function Display of average active power Setting of integrating time Harmonic analysis function Available DC, Hz to 5 khz Standard Not available Not available min. to 999 hr 59 min. (units of min.) Available (optional) 3

4 Applications and Characteristics Measurement of Small Current and Power of Home Appliances (WT2) The power consumption of home appliances such as videocassette recorders and TV sets is progressively being reduced, not only during operation but also on standby. th its low current range *, the WT2 can precisely measure small (standby) current and power. Also, the D/A output function *2 allows measured data of voltage, current, power, etc. to be recorded in a recorder or other units. *Current range of 2 ma or below (5//2/5//2 ma) is available only in the WT2. *2When the D/A output function is added, the WT2 has 4 D/A output channels; the WT3 has 2 D/A output channels. Voltage and current D/A output of ±5 V DC AC power supply, 5/6 Hz Recorder Voltage Current Measurements of Harmonic Current Using a Clamp Sensor The WT2/WT3 can be equipped with an external sensor input for measuring current with a clamp sensor. This allows current to be measured in the field without releasing connections. The harmonic analysis function allows current components of up to the 5th order to be analyzed. Data of voltage, current, and harmonic components can be output to an external printer thanks to the communication function. The comparator function (maximum of 4 channels) enables GO/NOGO judgement of products to be made. Example of Surge thstand Characteristics for Current Input of WT2 Current (Arms) Time width (s).5a2a 5mA2mA Example of Surge thstand Characteristics for Current Input of WT3 Current (Arms) Time width (s) Influence of Commonmode Voltage on the Reading Current GPIB or RS232C AC clamp NC COM Effect (%) NO Reference value Actual value WT2/WT3 Frequency of commonmode voltage (Hz) Example of Application of D/A Output Accuracy Characteristics of Frequency Power DC step input Reference value Actual value Error (%) Response of D/A output 4 Observation time of 2 seconds Input frequency (Hz)

5 Specifications Input Input circuit type Item Rated inputs (range) Equipment loss (input resistance) Instantaneous maximum allowable input for one cycle, 2 ms Instantaneous maximum allowable input for sec. Continuous maximum allowable input Continuous maximum commonmode voltage (at 5/6 Hz input) Commonmode rejection ratio at 6 Vrms between input terminal and case Input terminals A/D conversion Range switching Automatic range switching Measurement mode switching Voltage V Resistance voltage divider 5/3/6/5/3/6V Input resistance: Approx. 2 MΩ, Input capacitance: Approx. 3 pf Peak voltage of 2.8 kv or rms of 2. kv, whichever is less Peak voltage of 2. kv or rms of.5 kv, whichever is less Peak voltage of.5 kv or rms of. kv, whichever is less Floating input Current A Shunt input Direct input: 5//2/5//2 ma (for WT2 only).5//2/5//2 A (for WT2/WT3) External input (optional): 2.5/5/ V or 5//2 mv Direct input: Approx. 6 mω + approx.. µh (.5 to 2 A, WT2/WT3),Approx. 5 mω (5 ma to 2 ma, WT2) External input: 2.5/5/ V approx. kω or 5//2 mv approx. 2 kω.5 to 2 A (WT2/WT3): Peak current of 45 A or rms of 3 A, whichever is less 5 to 2 ma (WT2): Peak current of 5 A or rms of A, whichever is less For external input, the peak value is equal to or less than times range..5 to 2 A (WT2/WT3): Peak current of 5 A or rms of 4 A, whichever is less 5 to 2 ma (WT2): Peak current of 3 A or rms of 2 A, whichever is less For external input, the peak value is equal to or less than times range..5 to 2 A (WT2/WT3): Peak current of A or rms of 25 A, whichever is less (WT2) Peak current of A or rms of 3 A, whichever is less (WT3) 5 to 2 ma (WT2): Peak current of 3 A or rms of 2 A, whichever is less For external input, the peak value is equal to or less than 5 times range. 6 Vrms (with the output connector protective cover used) CAT II, 4 Vrms (with the output connector protective cover removed) CAT II th voltage input terminals short and current input terminals open, 5/6 Hz, 8 db or more (±.% of range or less) Reference value: 5 khz max., ±{(maximum range rating)/(range rating). % of rng} or less (voltage range,.5 A to 2 A current range) ±{(maximum range rating)/(range rating).2 % of rng} or less (WT2, 5 ma to 2 ma range).% or more. The unit of "f" is khz. Binding posts Direct input: Large binding posts, External input: Safety terminals Simultaneous conversion of voltage and current inputs, Resolution: 2 bits, Maximum conversion rate: Approx. 26 µs (at approx. 38 khz) Range can be selected manually, automatically, or by communication control. Range up: When the measured value exceeds % of the rated range or the peak value exceeds approximately 3% of the rated range Range down: When the measured value becomes less than 3% of the rated range and the peak value is less than approximately 3% of the subordinate range One of the following modes can be set (manually or by communication control): RMS: True RMS measurements for both voltage and current; V MEAN: Rectified mean calibrated to an RMS sine wave measurement for voltage, and true RMS measurement for current; DC: Mean value measurement for both voltage and current Notes: Direct input and external sensor input of current cannot be used simultaneously. When the input is switched for use, note that the ± terminals are shared. Measurement Functions Item Method Frequency range Crest factor Display accuracy Accuracy (within 3 months after calibration) Conditions: Temperature: 23 ± 5 C Humidity: 3 to 75% R.H. Supply voltage: V ± 5% Input waveform: Sine wave Commonmode voltage: V DC Filter: ON at 2 Hz or less Scaling: OFF After CAL is performed, accuracy is assured by YOKOGAWA calibration system. Note: The unit of "f" in accuracy expressions is khz. Effect of power factor Note: The unit of "f" in accuracy expressions is khz. Effective input range Accuracy (within 2 months after calibration) Temperature coefficient Display update rate DC: Hz f 45Hz : 45Hz f 66Hz : 66Hz f khz : khz f khz : khz f 2kHz Voltage/current Reference value 2kHz f 5kHz : ± (.5 % of rdg +.5 % of rng) ± [{.5 (f)}% of rdg] *DC: ±.2% of range is added if the.5/ A range is selected (WT3 only) Active power Digital sampling method and summation averaging method DC, Hz to 5 khz "3" at rated input ± (.2 % of rdg +.2 % of rng)* ± (.3 % of rdg +.2 % of rng) ± (.5 % of rdg +. % of rng) ± (.3 % of rdg +.2 % of rng) ± (.2 % of rdg +.3 % of rng) ± {(.5 )% of rdg} ± (.5 % of rdg +.5 % of rng) ± [{.5 (f)}% of rdg] DC: Hz f 45Hz : 45Hz f 66Hz : 66Hz f khz : khz f khz : khz f 2kHz : ± (.3 % of rdg +.3 % of rng)* ± (.5 % of rdg +.3 % of rng) ± (.2 % of rdg +. % of rng)(wt2) ± (.25 % of rdg +. % of rng)(wt3) ± (.5 % of rdg +.3 % of rng) ± (.3 % of rdg +.5 % of rng) ± {(.8 f)% of rdg} ± (.8 % of rdg +.8 % of rng) ± [{.9 (f)}% of rdg] Reference value 2kHz f 5kHz : ± (.8 % of rdg +.8 % of rng) ± [{.25 (f)}% of rdg] *DC: ±.2% of range is added if the.5/ A range is selected (WT3 only) cosϕ 45 Hz f 66 Hz: Add ±.25% of range to display accuracy. Reference data (5 khz max.): ±{( x f)% of rng} > cosϕ > Add the value of the influence of cosϕ times tanϕ to display accuracy. Note that ϕ represents the phase angle between voltage and current. For the input range of % to %, the above specified accuracy is valid. For the input range of % to 3%, the above specified reading accuracy increased by.5 times is added to the accuracy. The above specified reading accuracy increased by.5 times is added to the accuracy (within 3 months after calibration). ±.3% of range/ C at 5 to 8 C and 28 to 4 C 4 times/s Note: "rdg" means reading and "rng" means range. Frequency Measurement Input: One of V, V2, V3, A, A2, and A3 is selected. Operating principle: Reciprocal counting method Frequency range: Hz to 5 khz Accuracy: ±(.% of rdg + digit) Minimum input is more than 3% of rated range. When an input frequency is less than 2 Hz, FILTER must be ON to obtain the specified accuracy. Minimum input frequency is more than 2% of frequency measurement range. Communication Either GPIB or RS232C is selected. GPIB Electrical and mechanical specifications: IEEE Std (JIS C 9987) Functional specifications: SH, AH, T5, L4, SR, RL, PR, DC, DT, C Protocol: IEEE Std Code used: ISO (ASCII) code Address: to 3 talker/listener addresses are settable. RS232C Transmission mode: Startstop synchronization Baud rate: 75, 5, 3, 6, 2, 24, 48, 96 bps 5

6 6 Computation phase 2wire phase 3wire 3phase 3wire (twopowermeter method) 3phase 3wire (threepowermeter method) 3phase 4wire Computing range Display resolution Computing accuracy (relative to the value calculated from measured values) Active power (W) W+W3 i, 2, 3 W+W2 +W3 Apparent power (VA) Vi Ai VA+VA 3 Vi Ai W+W3 3 2 (VA+VA 3) Vi Ai i, 2, 3 i, 2, 3 (Note that W2 does not have physical meaning.) W W+W3 VAV A 3 3 (VA+VA2 +VA 3) Vi Ai i, 2, 3 VA+VA2 +VA 3 Depends on Depends on selected V selected V and and A ranges. A ranges. ±.5% of VA range vari Reactive (var) (VA) 2 W 2 vari () 2 2 Σ var var+var3 Power factor (PF) Σ PF Note :The apparent power (VA), reactive power (var), power factor (PF), and phase angle (deg) measurements in this instrument are computed digitally from the voltage, current, and active power. If the input is nonsinusoidal, the measured values may differ from those obtained with instruments employing different measurement principles. Note 2:When the current or voltage is less than.5% of the range, VA and var will be displayed as, and PF/deg will be displayed as an error. Note 3:The Lead and Lag are displayed for V and A input at 5% or more of the rated range. The detected lead/lag accuracy is ±5 degrees over the frequency range of 2 Hz to 2 khz. Note 4:In a Σvar calculation, the var value of each phase is calculated as a negatively signed value when the phase of the current input is advanced with respect to the voltage input, and is calculated as a positively signed value when the phase is lagging. * The WT2 can provide 5digit display (note that the resolution is 2). PFi PFi () 2 2 Σ var Σ PF var+var3 vari () 2 2 i, 2, 3 Σ var var+var3 vari () 2 2 i, 2, 3 Σ var var+var2+var3 Same as apparent power (var ) PFi W VA i, 2, 3 Σ PF PFi i, 2, 3 Σ PF to to 9999* 9999* 9999* ±.* ±.5% of var range.5 Display Function Display type: 7segment LED Number of displays: 3 Display A B C Displayed value V, A, W, VA, var (each element), elapsed integrating time V, A, W, PF, deg (each element), % (contents ratio in %, THD) V, A, W, V AHz, ±Wh, ±Ah (each element), Vpk, Apk, MATH * In the WT2 either 4 or 5 digits for display can be selected. ϕ i cos ( ) Σϕ cos ( ) ΣVA ϕ i Phase angle (deg) W cos ( ) VA cos ( ) Σϕ cos ( ) ΣVA ϕ i cos ( ) i, 2, 3 Σϕ cos ( ) ΣVA ϕ i cos ( ) i, 2, 3 Σϕ cos ( ) ΣVA 8 to to 8 ± 8. Resolution (power factor ±.5) Maximum Reading V, A, W: 9999 Wh, Ah: V, AHz : 9999 Unit: m, k, M, V, A, W, VA, var, Hz, h±, deg, % Display update rate: 4 times/s Response time: Approx..5 s (time for displayed value to settle within specified accuracy of final value after step change from % to % or % to % of rated range) Display scaling function Significant digits: Selected automatically according to significant digits in the voltage and current ranges Setting range:. to 9999 (WT2),. to (WT3) Averaging function: Either of the following two algorithms can be selected: Exponential averaging Moving averaging Response can be set; for exponential averaging, the attenuation constant can be selected and for moving averaging, the number of averages (N) can be set to 8, 6, 32, or 64. Peak overrange display The alarm LED will light up if the rms value is greater than 4% of the range or the peak value is greater than 3% of the range. MAX hold function (WT2 only) Capable of storing the maximum values for V, A, W, VA, var, Vpk, and Apk. MATH function Method: Integrator Function When the DISPLAY C function is set to MATH, the efficiency (WT3 only) and input crest factor can be measured, and the results of four arithmetic operations of measured values can be displayed on Displays A and B as well as the average active power after timeconversion of integrating power (WT2 only). Display resolution: Depending on integrated value, the resolution will be changed (for WT2). Depending on elapsed time value, the resolution will be changed (for WT3). Maximum display: to MWh/MAh Modes: Standard integration mode (timer mode) Continuous integration mode (repeat mode) Manual integration mode Timer: When the timer is set, integration will be stopped automatically. Setting range: h: min: sec to h: min: sec (WT2) Setting range: h: min to 999 h:59 min (WT3) (When set time is, the manual integration mode is automatically selected.) Type: Standard type Adds active power and current value of normal measurements. Advanced type (WT2 only) Integrates active power and current values in short time intervals, not depending on input signal period. Count overflow: If the integration count exceeds MWh/MAh or MWh/MAh, integration stops and the elapsed time is held on the display. Accuracy: ± (display accuracy +.2% of rdg) Timer accuracy: ±.2% Remote control: Start, stop, and reset can be remotely controlled by an external contact signal. Note that this is available only when the /DA4 or / DA2 option has been installed. Internal Memory Function Measurement data Number of data that can be stored: WT2 (25342): 6 blocks WT3 (25352): 3 blocks WT3 (25353): 2 blocks Writing interval: 25 ms, or s to 99 h:59 min:59 sec Reading interval: 25 ms, or s to h (both intervals can be set in units of second) Panel setup information: Fourpattern information can be written/read. D/A Converter (Optional) Output voltage: ±5 V DC FS (approx. ±7.5 V maximum) at rated value or range Number of output channels: 2 when the /DA2 option is installed; 4 when the /DA4 option is installed Output data selection: Can be selected for each channel. Accuracy: ± (display accuracy +.2% of range) Update rate: Same as display update rate Temperature coefficient: ±.5% of f.s./ C Output format Frequency Integration Other items D/A output 7.V 5.V D/A output 7.5V 5.V 2.5V.5V Displayed value 4% % % % 4% Hz Hz khz khz 5kHz Displayed value 4% input of the rated value t: Rated value setting time Output 7.V 5.V V 5.V 7.V For PF and deg, a value between ±5 and ±7 V will not be output. If an error occurs, the output will be approx. 7.5 V. 4% % Rated value input D/A output 7.5V 7.V 5.V V 5.V 7.V 7.5V t % 4% Integration time Displayed value

7 External Input (Optional) Either /EX or /EX2 can be selected as a voltageoutputtype current sensor. /EX: 2.5/5/ V /EX2: 5//2 mv Specifications: See the Input item. Comparator Output (Optional) Output method: Normally open and normally closed relay contact outputs (in pairs) Number of output channels and channel setup: 4 (settable for each channel) Contact capacity: 24 V/.5 A D/A output (4 channels): See the D/A Converter (Optional) item. External Control and Input Signals (only when the D/A or /CMP option has been installed) External control and input/output signals: EXTHOLD, EXTTRIG, EXTSTART, EXTSTOP, EXTRESET, INTEGBUSY Note: That the /DA4 or /DA2 option must be installed. Note: Only EXTHOLD and EXTTRIG are available when the / CMP option has been installed. Input level: TTL negative pulse General Specifications EMI standard: EN55 Group Class A EN5822: 995 Safety standards: EN6 Overvoltage Category II Pollution degree 2 Warmup time: Approx. 3 min. Operating temperature and humidity range: 5 to 4 C, 2 to 8% R.H. (no condensation) Storage temperature: 25 to 6 C (no condensation) Operating altitude: 2 m or less Insulation resistance: Between voltage input terminals and case Between current input terminals and output terminals Between voltage input terminals and current input terminals Between voltage input terminals of each element Between current input terminals of each element Between voltage input terminals and power plug Between current input terminals and power plug Between case and power plug The above values must be 5 MΩ or more at 5 V DC. thstanding voltage: Between voltage input terminals and case Between current input terminals and output terminals Between voltage input terminals and current input terminals Between voltage input terminals of each element Between current input terminals of each element Between voltage input terminals and power plug Between current input terminals and power plug The above values must be 37 V for minute at 5/6 Hz. Between case and power plug: 5 V for minute at 5/6 Hz Power supply: Any power supply voltage between and 24 V; frequency: 5/ 6 Hz Vibration test conditions: Sweep test Frequency: 8 to 5 Hz sweep, all three directions for minute Endurance test Frequency: 6.7 Hz, all three directions; amplitude of 4 mm for 2 hr Impact conditions: Impact test: Acceleration of 49 m/s 2, all three directions Freefall test Height: mm, time for each of four sides Power consumption: WT2: 35 VA max., WT3: 5 VA max. (for power supply of 24 V) WT2:25 VA max., WT3: 32 VA max. (for power supply of V) External dimensions: WT2:Approx. W H D: (mm) (not including projections) 83/8 3/2 33/4 (inch) (not including projections) WT3:Approx. W H D: (mm) (not including projections) 83/8 53/6 33/4 (inch) (not including projections) Weight: WT2:Approx. 3. (kg), 6.6 (lbs.) WT3:Approx. 5. (kg),. (lbs.) Accessories: Power cord: UL/CSA, VDE, SAA or BS standard, pc. External Dimension Unit: mm Harmonic Analysis Function (Optional) Method: Synchronization to the fundamental frequency by using a phase locked loop (PLL) circuit Frequency range: Fundamental frequency between 4 Hz and 44 Hz Display resolution: 9999 (WT3), 9999 or 2 (WT2) Items analyzed: V, A, W, deg (WT2); V, V2, V3, A, A2, A3, W, W2, W3, deg, deg2, deg3 (WT3), each harmonic component, total Vrms, total Arms, total active power, PF of the fundamental wave, phaseangle of fundamental wave, total harmonic distortion ratio in %, and contents ratio in % Note that simultaneous analysis can be made for one specified input mode. Sampling speed/method: The sampling speed depends on the fundamental frequency to be input: Input Sampling ndow frequency frequency up to the n'th Order range harmonic 4f<7Hz f 52Hz 7f<3Hz f 256Hz 3f<25Hz f 28Hz 25f44Hz f 64Hz FFT number of points: 52 points FFT FFT calculation accuracy:32 bits ndow: Rectangular window Display update interval: Approx. 3 sec. Accuracy: Model and Suffix Codes Model Suffix Code Power cord D F R Q Optional features /C /C2 /EX /EX2 /HRM /DA4 /CMP period of f 2 period of f 4 period of f 8 period of f ±.2% of range is added to the normal display accuracy. Description WT2, input element model UL/CSA standard VDE standard SAA standard BS standard GPIB communication function RS232C communication function External input 2.5/5/ V External input 5//2 mv Harmonic analysis function 4channel D/A output Comparator & D/A, each of 4 channels Note: The WT2 communication feature cannot be modified or provided later after delivery of the product. Model Interface C C2 Supply voltage Power cord Optional features Suffix Code D F R J /EX /EX2 /HRM /DA2 /CMP ring and Model ring Singlephase, 2wire Singlephase, 3wire Threephase, 3wire (2powermeter method) Threephase, 3wire (3powermeter method) Threephase, 4wire Accessories Description WT3, 2input element model WT3, 3input element model GPIB communication function RS232C communication function Any power supply voltage between and 24 V UL/CSA standard VDE standard SAA standard BS standard External input 2.5/5/ V External input 5//2 mv Harmonic analysis function 2channel D/A output Comparator & D/A, each of 4 channels Model Name Model or Part Number Specifications Order Quantity 75533E2 Singlemounted WT2 for EIA J2 Singlemounted WT2 for JIS E J2 Dualmounted WT2 for EIA Dualmounted WT2 for JIS 75533E3 Singlemounted WT3 for EIA J3 Singlemounted WT3 for JIS 75534E3 Dualmounted WT3 for EIA J3 Dualmounted WT3 for JIS 7

8 Related Products WT2/WT23 Digital Power Meter Enhanced power meter, incorporating a total harmonic analysis function conforming to the IEC standard. WT/WT3/WT3M Digital Power Meter Generalpurpose midclass models suitable for a wide range of applications Outstanding performance:.3%/dc, 2 Hz to 5 khz High accuracy:.8% (45 to 66 Hz) Total harmonic current/flicker conforming to IEC32 and 3 can be measured. Frequency response: DC,.5 Hz to 3 khz High accuracy:.2% (45 to 66 Hz) Overall efficiency of a motor can be measured by using the motor evaluation function (only WT3M). PZ4 Power Analyzer New concept power meter capturing power fluctuations as waveforms DL78E/DL76 Digital Scope For simultaneous measurement of voltage, temperature, distortion, and logic Frequency response: DC to 2 MHz Sampling speed: 5 MS/s maximum Fundamental power accuracy: ±(.% of rdg +.25% of rng) Voltage and current waveform display and analysis function Motor evaluation function (when equipped with module) Inputs of up to 8 analog channels (DL78E)/6 analog channels + 32 logic bits (DL76) Eight types of mixed plugin input units Record length of 64M words maximum (DL76 s 6M words/ ch. model) Builtin HDD (optional) YOKOGAWA ELECTRIC CORPORATION Measurement Sales Dept. 932, Nakacho 2chome, Musashinoshi, Tokyo 8875, JAPAN Phone: , Fax: YOKOGAWA CORPORATION OF AMERICA 2 Dart Road, Newnan, Georgia 3265, U.S.A. Phone: , Fax: YOKOGAWA EUROPE B.V. Vanadiumweg, 382 PX Amersfoort, THE NETHERLANDS Phone: , Fax: YOKOGAWA ENGINEERING ASIA PTE. LTD. 5 Bedok South Road, Singapore Phone: , Fax: YOKOGAWA ELECTRIC CORPORATION Test & Measurement Business Division 55 Takamurocho, Kofushi, Yamanashiken, Japan Phone: , Fax: Represented by : MM7E Subject to change without notice. [Ed : 5/b] Printed in Japan, 9(YG) All Rights Reserved, Copyright 995, Yokogawa Electric Corporation.

ENERGY SAVING TOOLS. Digital Sampling Power Meters with Superior Cost Performance. Digital Power Meters

ENERGY SAVING TOOLS. Digital Sampling Power Meters with Superior Cost Performance. Digital Power Meters Established 98 Advanced Test Equipment Rentals www.atecorp.com 8-44-ATEC (2832) ENERGY SAVING TOOLS Digital Sampling Power Meters with Superior Cost Performance Digital Power Meters WT2/WT23 Basic power

More information

WT210/WT at rated. 5 ma range. input Low current (WT210) DC 0.5 Hz. to100 khz. Digital Power Meters ±0.2% WT210/WT230 Digital Power Meters

WT210/WT at rated. 5 ma range. input Low current (WT210) DC 0.5 Hz. to100 khz. Digital Power Meters ±0.2% WT210/WT230 Digital Power Meters WT2/WT23 Digital Power Meters WT2/WT23 Digital Power Meters Digital Sampling Power Meters with Superior Cost Performance Low power measurement (IEC623) Harmonic measurement Compact design (half-rack size)

More information

Technical Specifications for Portable 3-Ø Power Analyzer

Technical Specifications for Portable 3-Ø Power Analyzer Technical Specifications for Portable 3-Ø Power Analyzer SCOPE: This specification covers the general specifications of 3-phase power analyzer that can be used to measure the no load and full load losses

More information

Digital Sampling Power Meter. Digital Power Meter and Power Analyzer WT210/WT230 WT1600 WT2010/WT2030 PZ4000

Digital Sampling Power Meter. Digital Power Meter and Power Analyzer WT210/WT230 WT1600 WT2010/WT2030 PZ4000 Total Solution Digital Sampling Power Meter Digital Power Meter and Power Analyzer WTSERIES & PZ WT0/WT0 WT600 WT00/WT00 Information on the features and functions of Yokogawa's WT series & PZ, accessories,

More information

High-accuracy measurement of standby to operating power

High-accuracy measurement of standby to operating power POWER METER PW3335 Power Measuring Instruments Single-Phase AC/DC Power Meter High- of standby to operating power Wide measurable range : 10 μa to 30 A, 60 mv to 1000 V Basic for voltage, current and power

More information

High-accuracy measurement of standby to operating power

High-accuracy measurement of standby to operating power POWER METER PW3335 Single-Phase AC/DC Power Meter High- of standby to operating power Wide measurable range : 10 μa to 30 A, 60 mv to 1000 V Basic for voltage, current and power : ±0.1%* Frequency bandwidth

More information

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX 756 & 7562 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is

More information

The world s best seller. WT300E Series Digital Power Meter. Bulletin WT300E-01EN

The world s best seller. WT300E Series Digital Power Meter. Bulletin WT300E-01EN The world s best seller WT300E Series Digital Power Meter Bulletin WT300E-01EN The WT300E series is the enhanced version of Yokogawa s 5 th generation of compact power meters. The world s best-selling

More information

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is a high-accuracy,

More information

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool An Energy Saving Support Tool POWER HiTESTER Power Measuring Instruments 3332 STANDBY MODE OFF MODE Single-phase, 2-wire type that can accurately measure even standby power Accurate evaluation of consumption

More information

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display 5 1/2 Digit DMM Series Enabling Dual Input and Display R6451A/6452A R6451A: General-Purpose Low-Price DMM with Standard Functions R6452A: Full-Functional DMM with Dual- Channel Input and Dual Display (Photo

More information

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback

More information

Accurately measure devices up to 1000 V/65 A AC/DC with direct input

Accurately measure devices up to 1000 V/65 A AC/DC with direct input POWER METER PW3336, PW3337 High-precision, 3-channel power meter with built-in harmonic measurement Accurately measure devices up to 1000 V/65 A AC/DC with direct input The PW3336 (2-channel) and PW3337

More information

APPLICATIONS. Oscilloscope Display. Harmonic Measurement. High Precision Measurement up to 0.1% Power Supplies Tests Motor Tests

APPLICATIONS. Oscilloscope Display. Harmonic Measurement. High Precision Measurement up to 0.1% Power Supplies Tests Motor Tests YOUR POWER TESTING SOLUTION IT9100 Power Meter Oscilloscope Display Harmonic Measurement High Precision Measurement up to 0.1% IT9100 Power Meter APPLICATIONS Power Supplies Tests Motor Tests Household

More information

3331, 3332 POWER HiTESTER

3331, 3332 POWER HiTESTER 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com An Energy Saving Support Tool 2002 3331, 3332 POWER HiTESTER Power measuring instruments 3332: Single-phase, 2-wire type that

More information

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The

More information

The PW3336 (2-channel) and PW3337 (3-channel) can measure DC and a variety of power connections ranging from single-phase 2-wire to 3-phase 4-wire*.

The PW3336 (2-channel) and PW3337 (3-channel) can measure DC and a variety of power connections ranging from single-phase 2-wire to 3-phase 4-wire*. POWER METER PW3336/PW3337 Power Measuring Instruments High-precision, 3-channel power meter with built-in harmonic measurement Accurately measure devices up to 1000 V/65 A AC/DC with direct input The PW3336

More information

POWER HiTESTER 3331, 3332

POWER HiTESTER 3331, 3332 An Energy Saving Support Tool POWER HiTESTER 3331, 3332 Power measuring instruments 3332: Single-phase, 2-wire type that can accurately measure even standby power 3331: Single-phase, 3-wire and three-phase,

More information

Fluke Norma 4000/5000

Fluke Norma 4000/5000 Fluke Norma 4000/5000 High Precision Power Analyzers Reliable, highly accurate measurements for the test & development of power electronics Technical Data Compact Fluke Norma Series power analyzers include

More information

5500A. Multi-Product Calibrator. Extended Specifications 2005

5500A. Multi-Product Calibrator. Extended Specifications 2005 5500A Multi-Product Calibrator Extended Specifications 2005 5500A Specifications The following paragraphs detail specifications for the 5500A Calibrator. The specifications are valid after allowing a warm-up

More information

Wide Spectrum Power Meter for Comprehensive Device Assessment

Wide Spectrum Power Meter for Comprehensive Device Assessment POWER HiTESTER 3193-10 Wide Spectrum Power Meter for Comprehensive Device Assessment Printer is optional unit DC/0.5Hz to 1MHz broad-band POWER HiTESTER measures up to 6 systems simultaneously. The POWER

More information

Signal Input and Trigger

Signal Input and Trigger Signal Input and Trigger Number of input channels 2 (CH A and CH B) Input coupling Input connector DC/AC BNC connector Input impedance 50Ω/1 MΩ, 23pF (typical value *1 ) Frequency characteristics When

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN Each click of a dial opens a doorway to precision. Precision DC Calibrator Bulletin -01EN Yokogawa is a leader in providing high precision measurement equipment electric voltage/current, electric resistance,

More information

Digital Power Meter. IM E 4th Edition

Digital Power Meter. IM E 4th Edition Digital Power Meter 4th Edition Product Registration Thank you for purchasing YOKOGAWA products. YOKOGAWA provides registered users with a variety of information and services. Please allow us to serve

More information

Fluke 3540 FC Three-Phase Power Monitor

Fluke 3540 FC Three-Phase Power Monitor TECHNICAL DATA Fluke 3540 FC Three-Phase Power Monitor The 3540 FC Three-Phase Power Monitor is a compact device to monitor three-phase systems and stream data to the Fluke Connect Cloud. The measurement

More information

General Specifications

General Specifications General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring

More information

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM DATA SHEET 34450A Multimeter 5.5 Digit Dual Display, Benchtop DMM Features Fast reading speed of up to 190 readings/sec 0.015% DCV accuracy Multiple connectivity options USB 2.0, Serial Interface (RS-232)

More information

Effective solution for AC power calibration. LS3300 AC power calibrator. Bulletin LS EN

Effective solution for AC power calibration. LS3300 AC power calibrator. Bulletin LS EN Effective solution for AC power calibration AC power calibrator Bulletin -01EN Introduction to broad industrial fields 2 Yokogawa has been supplying precision measuring instruments of the highest quality

More information

Fluke Norma 4000/5000

Fluke Norma 4000/5000 Fluke Norma 4000/5000 High Precision Power Analyzers Reliable, highly accurate measurements for the test & development of power electronics Technical Data Compact Fluke Norma Series power analyzers include

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

Clamp-on Testers. The 300, 310, 2343 and 2345 Series of Clamp-on Testers

Clamp-on Testers. The 300, 310, 2343 and 2345 Series of Clamp-on Testers Clampon Testers The 300, 310, 2343 and 2345 Series of Clampon Testers You can choose from a wide variety of models: 300 series of AC and AC/DC operated miniature models and batterydriven miniature models

More information

n DC Voltage Measurement (DCV) 7461A n AC Voltage Measurement (ACV, ACV (AC+DC)) 7451A 7461A/7451A Additional error depending on the integration time

n DC Voltage Measurement (DCV) 7461A n AC Voltage Measurement (ACV, ACV (AC+DC)) 7451A 7461A/7451A Additional error depending on the integration time Specifications Unless otherwise specified, the measurement accuracy is guaranteed for one year under the following conditions: Temperature; 23±5 C, relative humidity; 85% or less (75% or less in resistance

More information

General Specifications

General Specifications General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with

More information

General Specifications

General Specifications General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent

More information

General Specifications

General Specifications General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal

More information

3166 CLAMP ON POWER HiTESTER

3166 CLAMP ON POWER HiTESTER 2001 3166 CLAMP ON POWER HiTESTER Power measuring instruments 9298 CLAMP ON SENSOR Get the Current Effectiveness of Energy Conservation and Harmonic Wave Measures all in one instrument New type of clamp

More information

5520A. Multi-Product Calibrator. Extended Specifications 2005

5520A. Multi-Product Calibrator. Extended Specifications 2005 5520A Multi-Product Calibrator Extended Specifications 2005 5520A Specifications The following tables list the 5520A specifications. All specifications are valid after allowing a warm-up period of 30 minutes,

More information

WT300 Series THE 5TH GENERATION OF THE WORLD'S BEST SELLING POWER METER

WT300 Series THE 5TH GENERATION OF THE WORLD'S BEST SELLING POWER METER Digital Power Meter WT300 Series DIGITAL POWER METER THE 5TH GENERATION OF THE WORLD'S BEST SELLING POWER METER High Performance and Reliability l Basic Accuracy of 0.% of Reading l Low Measurement down

More information

Highest accuracy & precision. WT3000E Series Precision Power Analyzers ±0.04% WT3000E. Total. Bulletin WT3000E-01EN ±0.10% ±0.15% ±0.

Highest accuracy & precision. WT3000E Series Precision Power Analyzers ±0.04% WT3000E. Total. Bulletin WT3000E-01EN ±0.10% ±0.15% ±0. Highest accuracy & precision Total ±0.04% Series Precision Power Analyzers ±0.10% WT1800E ±0.15% WT300E Series ±0.20% Bulletin -01EN WT500 PX8000 Devices such as solar inverters are already working at

More information

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals The Fluke 6100A Electrical Power Standard The most accurate, comprehensive and flexible source of electrical power signals Measurement validation for electrical power applications The importance of accurate

More information

General Specifications

General Specifications General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring

More information

5MS/s. Power Analyzer

5MS/s. Power Analyzer Established 98 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (83) 5MS/s Power Analyzer Wide bandwidth (DC, up to MHz) Accurately capturing of input waveforms using high-speed (maximum 5

More information

Clamp-on Testers. 300 Series and CL Series of Clamp-on Testers. Series

Clamp-on Testers. 300 Series and CL Series of Clamp-on Testers. Series Clampon Testers 300 Series and CL Series of Clampon Testers Series NEW NEW Leakage Clampon Tester with a sharp low pass filter function Leakage Clampon Tester capable of measuring from 1 ma AC Rich lineup

More information

APPLICATIONS. Oscilloscope Display. Harmonic Measurement. High Precision Measurement up to 0.1% Input Range 1000Vrms/50Arms

APPLICATIONS. Oscilloscope Display. Harmonic Measurement. High Precision Measurement up to 0.1% Input Range 1000Vrms/50Arms YOUR POWER TESTING SOLUTION IT9100 Power Meter Oscilloscope Display Harmonic Measurement High Precision Measurement up to 0.1% Input Range 1000Vrms/50Arms IT9100 Power Meter APPLICATIONS Power Supplies

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

3196 POWER QUALITY ANALYZER. Solve All Your Power Quality Problems ISO14001 JQA-E Power Measuring Instruments

3196 POWER QUALITY ANALYZER. Solve All Your Power Quality Problems ISO14001 JQA-E Power Measuring Instruments 2001 3196 POWER QUALITY ANALYZER Power Measuring Instruments Solve All Your Power Quality Problems ISO14001 JQA-E-90091 1 Identify power anomalies simply and surely! Problems in power quality that can

More information

Bipolar Output Working Standard

Bipolar Output Working Standard 6166 DC Voltage/Current Source 6½-digit working standard suitable for calibration High-accuracy and highly stable with bipolar output l Wide dynamic range and high resolution Voltage source: ±10nV to ±1200V

More information

DIGITAL HiTESTER 3237, 3238, 3239

DIGITAL HiTESTER 3237, 3238, 3239 DIGITAL HiTESTER,, 3239 4-terminal Ω function Advanced model Economically priced 3239 Outstanding performance for production lines with a sampling rate of 3.3 ms High-speed 5 1 /2 digit DMM The DIGITAL

More information

Fluke 3540 FC Three-Phase Power Monitor

Fluke 3540 FC Three-Phase Power Monitor Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com TECHNICAL DATA Fluke 3540 FC Three-Phase Power Monitor THREE-PHASE MONITORING AND STREAMING Monitor three-phase

More information

3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments.

3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments. 2004 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments Outstanding performance for production lines with a sampling rate of 3.3

More information

Voltech PM3000ACE UNIVERSAL POWER ANALYZER

Voltech PM3000ACE UNIVERSAL POWER ANALYZER Voltech PM3000ACE UNIVERSAL POWER ANALYZER Precision Power Analysis from Voltech Voltech launched the worlds first commercially available digital power analyzer, the PM1000, in 1987 and the worlds first

More information

DL-91 DL-92 DL-94 DL-97

DL-91 DL-92 DL-94 DL-97 DL-91 DL-92 DL-94 DL-97 (Accuracy 0.5%) (Accuracy 0.3%) (Accuracy 0.1%) (Accuracy 0.06%) OUTLINE These four digital multimeters of the DL-90 Series have been designed to meet the diversifying needs users

More information

California Instruments RP Series 2000 VA V 3 45 A. General purpose AC power sources

California Instruments RP Series 2000 VA V 3 45 A. General purpose AC power sources California Instruments RP Series General purpose AC power sources Portable Power, Low Cost. 2000 VA Output Power Front and Rear Outputs 16 Hz to 5000 Hz Frequency Range High Peak Current Capability Remote

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading

More information

5520A. Multi-Product Calibrator. Extended Specifications

5520A. Multi-Product Calibrator. Extended Specifications 5520A Multi-Product Calibrator Extended Specifications Specifications The following tables list the 5520A specifications. All specifications are valid after allowing a warm-up period of 30 minutes, or

More information

Digital Power Meter. IM E 1st Edition

Digital Power Meter. IM E 1st Edition Digital Power Meter 1st Edition Thank you for purchasing the YOKOGAWA WT200 Digital Power Meter. This User s Manual contains useful information regarding the instrument s functions and operating procedures,

More information

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES 7004 Digital Oscilloscopes DL4100 (700430) 38 220 427mm 15kg ( 15-11/16 8-11/16 16-7/8" 33.1 lbs) YOKOGAWA introduces a brand new digital oscilloscope with outstanding performance. The DL4100 / DL4200

More information

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter Digital Power Meter MODEL 6603/6604 DIGITAL POWER METER MODEL 6603/6604 Chroma 6603/6604 Power Meters are designed The 6603/6604 are packaged in a 3U high, half f o r m u l t i p l e p h a s e p o w e

More information

PM 6685 PM 6685R Universal Frequency Counter Rubidium Frequency Counter Calibrator

PM 6685 PM 6685R Universal Frequency Counter Rubidium Frequency Counter Calibrator PM 6685 PM 6685R Universal Frequency Counter Rubidium Frequency Counter Calibrator Technical Data Cal lab performance you can take anywhere Cal lab performance in the field The PM 6685 frequency counter

More information

DIGITAL STORAGE OSCILLOSCOPES

DIGITAL STORAGE OSCILLOSCOPES 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com DIGITAL STORAGE OSCILLOSCOPES Digital Storage Oscilloscope 100MS/s Acquisition (40MS/s 2 Acquisition) 100MHz 2 channel. OUTLINE

More information

79/26 Series III Multimeter

79/26 Series III Multimeter 79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position

More information

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom SMARTWAVE Programmable AC/DC Power Source PRODUCT OVERVIEW of cycles for each segment, the user can

More information

Because you can t afford downtime

Because you can t afford downtime Agilent AC6800 Series Basic AC Power Sources Because you can t afford downtime Data Sheet Engineer reliability into your designs with a new basic AC source alternative from Agilent and test with conidence

More information

PM6000. Voltech. Power Analyzer

PM6000. Voltech. Power Analyzer Voltech PM6000 Power Analyzer A New Standard in Power Analysis Up to 6 wattmeter channels Basic accuracy: 0.02% of reading Bandwidth: 10MHz Easy-to-use in all applications The Voltech PM6000 Power Analyzer

More information

Digital Power Meter. Yokogawa Electric Corporation. IM E 3rd Edition

Digital Power Meter. Yokogawa Electric Corporation. IM E 3rd Edition Digital Power Meter Yokogawa Electric Corporation 3rd Edition Foreword Thank you for purchasing the YOKOGAWA Model WT2030 Digital Power Meter. This User's Manual contains useful information regarding the

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

PQube 3 Specifications

PQube 3 Specifications PQube 3 Specifications Reference conditions for factory tests: 19~25 C, 10%~70% RH MAINS VOLTAGE MEASURING CHANNELS Measurement Channels Power Configuration/ Range of Nominal Input Voltage 3 Line to Neutral,

More information

Model CW120 Clamp-on Power Meter

Model CW120 Clamp-on Power Meter CW0 Model CW0 Clamp-on Power Meter Maintenance and long term monitoring of electrical equipment and electrical system. Current input (clamp) Voltage input External I/O controller port (integration start/stop

More information

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz CLAMP SENSOR Wide-band Models from DC to 1 MHz 3273-5 - 3276 CLAMP ON PROBES http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available

More information

1.2kV. The provides a low range error up to 0.05% and is capable of meeting the measurement uncertainty requirement of IEC 62301/EN50564.

1.2kV. The provides a low range error up to 0.05% and is capable of meeting the measurement uncertainty requirement of IEC 62301/EN50564. MODEL 66205 DIGITAL POWER METER MODEL 66205 The 66205 is the 2nd generation of the 66200 series power meter designed specifically for single channel measurement. Its state of art design is capable of providing

More information

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz CLAMP ON PROBE 327 series AC/DC CURRENT SENSOR CT686 series 99 Washington Street Melrose, MA 2176 Phone 781-665-14 Toll Free 1-8-517-8431 Visit us at www.testequipmentdepot.com Wide-band Models from DC

More information

7461A/7451A Digital Multimeter High-speed and variable integration time DMM supporting multiple applications

7461A/7451A Digital Multimeter High-speed and variable integration time DMM supporting multiple applications / Digital Multimeter High-speed and variable integration time DMM supporting multiple applications l Two models by use 6½-digit () 5½-digit () l Fast sampling : 20,000 readings/sec () 5,000 readings/sec

More information

Chapter 6 Specifications

Chapter 6 Specifications Chapter 6 Specifications DC Characteristics Function Range [2] Test Current or Burden Voltage DC Voltage DC Current Resistance [6] 24 Hour [3] T CAL ±1 Accuracy Specifications: ± (% of reading + % of range)

More information

Wide Spectrum Power Meter for Comprehensive Device Assessment. DC/0.5Hz to 1MHz broad-band POWER HiTESTER measures up to 6 systems simultaneously.

Wide Spectrum Power Meter for Comprehensive Device Assessment. DC/0.5Hz to 1MHz broad-band POWER HiTESTER measures up to 6 systems simultaneously. POWER HiTESTER 3193-10 Power measuring instruments AC/DC CURRENT SENSOR Rated at1000a rms Widebandwidth Super highprecision Printer is optional unit DC/0.5Hz to 1MHz broad-band POWER HiTESTER measures

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

Programmable AC Power Source Model 9801

Programmable AC Power Source Model 9801 Data Sheet Programmable AC Power Source The 9801 is both a programmable AC power source and measurement tool in a compact benchtop package. This fully programmable linear AC source delivers up to 300 VA

More information

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals The Fluke 6100A Electrical Power Standard The most accurate, comprehensive and flexible source of electrical power signals Measurement validation and calibration for electrical power applications The importance

More information

Fluke 1750 Three-Phase Power Recorder

Fluke 1750 Three-Phase Power Recorder TECHNICAL DATA Fluke 1750 Three-Phase Power Recorder Never miss capturing a disturbance with the exclusive threshold-free measurement system, it s automatic. Capture every measurement, every event, on

More information

8730 Electric Parameter Meter User manual

8730 Electric Parameter Meter User manual 8730 Electric Parameter Meter User manual ( Ver 2.10 ) Qingdao QINGZHI Instruments Co., Ltd. Address: 5th Floor, Building 1, Shenghe Building, No.58 Shandongtou Road, Laoshan District, Qingdao, China,

More information

Specifications. Specifications and Characteristics Specifications

Specifications. Specifications and Characteristics Specifications Specifications and Specifications Specifications All specifications are warranted. Specifications are valid after a 30-minute warm-up period and ±5 C from last calibration temperature. Bandwidth (-3dB)

More information

1587/1577 Insulation Multimeters

1587/1577 Insulation Multimeters 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters Power Analyzer Type WM14-96 Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

General Specifications

General Specifications General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available.

More information

15. Specifications WF1947/WF

15. Specifications WF1947/WF 15. Specifications 15.1 Oscillation Mode...15-2 15.2 Waveform...15-2 15.3 Frequency, Phase...15-3 15.4 Output Characteristics...15-3 15.5 Signal Characteristics...15-5 15.6 Modulated Oscillation Mode...15-7

More information

PM 6669 High-Precision Frequency Counter Specifications

PM 6669 High-Precision Frequency Counter Specifications PM 6669 High-Precision Frequency Counter Specifications Product Home Features Specifications Models, Options & Accessories Measuring functions Definitions Input specifications Auxiliary functions TimeBase

More information

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz CLAMP SENSOR Wide-band Models from to 1 MHz CLAMP ON PROBE 3276 1 CLAMP ON PROBE 3273-5 to 3276 Because current measurement requires the insertion of a shunt or a CT, the task often becomes difficult due

More information

Agilent 970-Series Handheld Multimeters Data Sheet

Agilent 970-Series Handheld Multimeters Data Sheet Agilent 970-Series Handheld Multimeters Data Sheet Benchtop features and performance with handheld convenience and price 3 1 /2and 4 1 /2 digits with dcv accuracy to 0.05% 1 khz to 100 khz frequency response

More information

Energy Management Modular Smart Power Transducer Type SPT-90

Energy Management Modular Smart Power Transducer Type SPT-90 Energy Management Modular Smart Power Transducer Type SPT-90 Class 0.5 (current/voltage) 16-bit µp-based modular smart power transducer Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among

More information

Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Instant value. Extreme values ors statistic measurements

Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Instant value. Extreme values ors statistic measurements Electronics & Software Charge Meter Universally Applicable for Piezoelectric Measuring Technology Type 5015A... This instrument can be used wherever mechanical quantities are measured with piezoelectric

More information

True RMS Bench Multimeter 5492B

True RMS Bench Multimeter 5492B Data Sheet True RMS Bench Multimeter 5492B True RMS Bench Multimeter The B&K Precision model 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service

More information

HP 34401A Specifications 8

HP 34401A Specifications 8 8 HP 34401A Specifications 8 DC Characteristics DC Characteristics Accuracy Specifications ± ( % of reading + % of range ) [ 1 ] Function Range [ 3 ] Test Current or Burden Voltage 24 Hour [ 2 ] 23 C ±

More information

7075 WAVEFORM GENERATOR SIGNAL SOURCE

7075 WAVEFORM GENERATOR SIGNAL SOURCE 2000 7075 WAVEFORM GENERATOR SIGNAL SOURCE Internal Sweep Sequence Functions Arbitrary Waveform Generator with Four Independently Controllable Channels The 7075 WAVEFORM GENERATOR includes both function

More information

Suitable for lighting and motor load, 1 Form A 50A latching relays

Suitable for lighting and motor load, 1 Form A 50A latching relays Suitable for lighting and motor load, 50A latching relays DJ-H RELAYS (ADJH) 9.0 5 1 0.2 9.0 5 New 1 FEATURES 1. High inrush capability Tungsten load (TV-20 class) Electronic ballast load (NEMA10) Capacitive

More information

8588A Reference Multimeter

8588A Reference Multimeter 8588A Reference Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of

More information

GAMMA 20 DIGITAL MULTIMETER

GAMMA 20 DIGITAL MULTIMETER Gamma 20 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel

More information

Fluke 83V and 87V Digital Multimeters

Fluke 83V and 87V Digital Multimeters Fluke 83V and 87V Digital Multimeters Detailed Specifications For all detailed specifications: is given as ±([% of reading] + [number of least significant digits]) at 18 C to 28 C, with relative humidity

More information

8558A 8 1/2 Digit Multimeter

8558A 8 1/2 Digit Multimeter 8558A 8 1/2 Digit Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need CLAMP ON HiTESTER SERIES Field measuring instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI

More information

Numerical, Waveform, and Trend Displays. Digital Power Meter WT 1600

Numerical, Waveform, and Trend Displays. Digital Power Meter WT 1600 Sophisticated Features Numerical, Waveform, and Trend Displays Digital Power Meter WT 600 Frequency Power Range DC, 0.5 Hz to MHz Basic Power : ±0.% Current Input Range: 0 ma to 5 A or A to 50 A Voltage

More information