ORCA-50 Handheld Data Terminal UHF Demo Manual V1.0
|
|
- Allan Short
- 5 years ago
- Views:
Transcription
1 ORCA-50 UHF Demo Manual V1.0 ORCA-50 Handheld Data Terminal UHF Demo Manual V1.0 Eximia Srl mario.difloriano@eximia.it 1 Eximia Srl -
2 Catelogue 1. UHF software operation and configuration Start the UHF Demo software Inventory ISO C tag Ordinary inventory Advanced options Access ISO C tags Read the tag operation Write the tag operation Lock the tag operation Inactivation the tag operation Select the tag operation Access the label may return an error message Inventory and access ISO B tags Inventory ISO B tag Access ISO B tags RF parameter settings Set the RF output power Set the radio frequency spectrum specification Set the antenna connection to receive Measure the return loss of the current antenna port Other settings of the reader Monitor the operating temperature Set the buzzer status Develop your own RFID applications... 2 Eximia Srl -
3 2017 RodinBell reserves all rights reserved for this document 1. UHF software operation and configuration 1.1 Start the UHF Demo software Click the UHF Demo icon to enter the connection interface, select ttys1 (rk_serial) serial port, click on the immediate connection to enter the main interface: The main interface for the ISO C tag inventory interface: 3 Eximia Srl -
4 1.2 Inventory ISO C label Inventory label, which is to identify multiple labels at the same time EPC number, which is the core function of UHF RFID reader, its performance directly determines the merits of the reader Ordinary inventory Click the Start Stock button or trigger the trigger of the handset handle. If the label is within the signal range, the EPC data of the label will be uploaded immediately and updated in real time. If you do not click on the end of the inventory or release the trigger, the reader will keep the inventory label, as shown below: 4 Eximia Srl -
5 The meaning of the data display is as follows: Inventoried Quantity There are a number of different tags that have been archived since the start of the inventory butto Speed Identify the speed of the label in units per second Total tag A label EPC record as a data, where real-time statistics to return a total of the number of data, which contains repeated read the same label data CMD exec time The time spent by each inventory command. The unit is milliseconds Total duration The total amount of time since the start of the inventory button was clicked. The unit is milliseconds The list of tags in the EPC number list (do not repeat) the meaning of the fields in the list box is as follows: ID The serial number of the data EPC The EPC number of the label PC Label protocol control word ID CNT The number of times the tag was identified RSSI The signal strength of the label is identified the last time Carrier frequency Carrier frequency of the label is identified the last time Advanced options Click the Advanced Options checkbox next to the Start Stock button. The following interface appears: 5 Eximia Srl -
6 The number of times each command is stored: The meaning of this parameter is the number of times the command is repeated. For example, set to 1, each inventory command to perform an anti-collision algorithm. Set to 2, then each disk command to repeat the implementation of two anti-collision algorithm, and so on Custom Session parameters: Click the Custom Session parameter check box, Session ID and Inventoried Flag will become optional, then click the Start button, the reader will be a custom Session and Target inventory 1.3 Access ISO C tags Click the "Access Tag" check box to access the interface of the access label, as shown below: 6 Eximia Srl -
7 The following will be one by one on how to carry out the label access operation Read the label operation The parameters of the read tag are entered in the interface shown below: The read tag needs to enter three parameters: the label area to be read, the start address and the data length. Note that here the starting address and The data length units are WORD, which is 16 bit double bytes. When the parameter is set, click the Read tab button. It should be noted that the input parameters to meet the specifications of the label, otherwise there will be an error When the operation completes successfully, the feedback shown below appears: 7 Eximia Srl -
8 How many tags are displayed and how many pieces of data are displayed in the tag list Write the label operation Write the interface of the label operation and read operations in the same area, the difference is that the write operation also need to provide access to passwords and write data to this information The password area is part of the electronic tag that stores the password (password). Including inactivation passwords and access passwords. The inactivation password and the access password are 4 bytes. Where: the address of the inactivation password is 00H-03H (in bytes); the address of the access password is 04H-07H After the operation is successful, the feedback shown below will appear: 8 Eximia Srl -
9 How many tags have been successfully operated, and how many pieces of data will be displayed in the list. Unlike the read tags, there is no content in the data column on the map above. The user can read the same area of the tag again to verify that the data is written correctly Note that the maximum write length is 32 Word(64 bytes,512bits) Lock the label operation The operation interface of the lock label is shown in the following figure: The lock tag must be provided with an access password to proceed. Note: The original password lock is invalid, it is recommended that users first modify the access password and then lock the label After the operation is successful, the following information will be returned: 9 Eximia Srl -
10 Similarly, how many tags are displayed in the list, and how many pieces of data are displayed in the list Kill the label operation The operation interface of the deactivation tag is shown in the following figure: The deactivation tag must provide an inactivation password and the inactivation password can not be Therefore, to destroy a label, first change the contents of the password inactivation password by writing a tag command After killing tag is successful, the following information is returned: the list How many tags are displayed in the list, as with all access to the tag, how many records are displayed in 10 Eximia Srl -
11 1.3.5 Select the label operation In many cases, we hope that no matter how many labels in the RF area, only for a known EPC number of labels to access operations, this time, you need to use the selected operation of the label function (EPC matching function) In the accompanying demo software, operate as follows: First save the label, get all the EPC number And then go to the interface to access the tag, select the EPC number to match. As shown below: When the selection is complete, click the selected tab, as shown below: 11 Eximia Srl -
12 Next, all access label operations will only be performed for labels with this EPC number If you want to cancel the EPC match, just click Cancel in the drop-down menu and click the Select button. As shown below: Access the label may return an error message In the process of access to the label operation, if the operation is not correct, there will be an error message, then we listed some common operational problems. Successful inventory but failed to access: 12 Eximia Srl -
13 The process of accessing a tag is actually divided into two steps, first by disk, and then accessed. The above prompt indicates that the label is successful, but the access operation is not possible In general, there are two reasons for this problem, one is the parameter settings are wrong, such as reading does not exist in the storage area, another reason is that the RF energy is not enough, access to the operating distance of the label is about the disk operating distance 60% to 70%, so if this is the case, please move the label closer to the antenna Access password is wrong: The cause of this problem, as described in the prompt, is that the access password is set incorrectly There is no operational label error: There are no labels available for operation in the RF area The meaning of the other return information, the user can refer to the document:uhf_rfid serial interface communication protocol _V2.38.pdf 13 Eximia Srl -
14 1.4 盘存和存取 ISO B 标签 Access ISO B tags ISO B label operation and ISO C label operation similar to the following figure: Every time you read the UID of the label once, the buzzer will be short. If the buzzer sounds slightly longer, then the reader starts the anti-collision function and simultaneously identifies multiple tags Access ISO B tags Access to the leaflet ISO B label can only be accessed. Click the Access tab button to select the label to be operated in the UID list, as shown in the following figure: The next operation is relatively simple, the user can operate on their own. Note the following points: The access operation must operate the label of the currently selected UID Can read multi-byte tag data at the same time, the length is not limited You can write multi-byte tag data at the same time, the length is not limited. If an error occurs, the 14 Eximia Srl -
15 reader stops writing but has already written The incoming data will not be changed, and the reader will return the number of bytes successfully written Only one byte of card data can be locked at a time Only one byte of data can be queried at a time Locked byte operations are permanent and irreversible 1.5 RF parameter settings After successfully connecting the reader, we need to set some of the most basic RF parameters, the output power and spectral range The setting of the RF parameters is set in the reader settings -> RF parameters page, as shown in the following figure: Set the RF output power RF output power refers to the antenna signal output RF signal strength. The unit is dbm 15 Eximia Srl -
16 The output power range is 0dBm - 33dBm. The default value is 30dBm (1 W). After this value is set, it will be automatically saved inside the machine, the machine is not lost after power failure 1.5.2Set the radio frequency spectrum specification In different areas, there are different requirements for radio frequency spectrum. There are two ways to set the reader's spectrum. Method 1: Use the default frequency of the reader. The default frequency of the reader can refer to the frequency parameter correspondence table in the communication protocol. The reader supports a frequency range of 865MHz - 868MHz, 902MHz - 928MHz. Use the drop-down boxes and buttons shown below to set the desired operating frequency range When setting the spectrum range, please note the following points: The starting frequency and end frequency can not exceed the range of RF specifications. 16 Eximia Srl -
17 The starting frequency must be less than or equal to the end frequency. Set the starting frequency and end frequency to the same frequency. The reader will work at constant frequency. This parameter is set, the reader's RF carrier will be in the restricted frequency range of random frequency hopping. The default RF spectrum specification is FCC (902MHz - 928MHz) Method 2: user-defined reader spectrum. The user uses three parameters to define the spectrum: the starting frequency, the frequency interval, the number of frequency points Note: In order to improve the anti-jamming performance, American Standard and European standard frequency band equipment selected hardware is different, it can not meet the compatible American standard, the European standard two bands Set the antenna connection to receive Antenna connection to receive the function is: read and write tags before checking whether the port is connected to the antenna, if not connected, then notify the user antenna is not connected. Before using the user to open this function, through the interface shown below to view, set the interface of this function as shown below: The sensitivity of the antenna detection is set by the user. Antenna detection sensitivity is the antenna port return loss value (Return Loss), the unit is db. The greater the value, the better the impedance matching between the antenna and the port. In general, a normal antenna can set this threshold to 3-6 db. Ceramic antenna or handset antenna can reduce the sensitivity lower. If the return loss threshold is set to 0, it means that this function is disabled and the status of the antenna connection will not be detected before reading and writing the tag. If the antenna is not connected, read and write tags when the operation will return to the antenna is not connected to the error message Measure the return loss of the current antenna port The return loss of the antenna port is detected at the interface shown below: 17 Eximia Srl -
18 1.6Other settings of the reader 1.6.1Monitor the operating temperature In the high-intensity continuous use of the reader, it will produce heat, the user can through the built-in temperature sensor to monitor the reader internal operating temperature, to avoid overheating (operating temperature of more than 65 degrees Celsius). If the temperature is too hot, you can stop reading and writing labels for a period of time The operating interface for monitoring the temperature is as follows: Set the buzzer status The buzzer provides the user with the sound information of the reader's use status. The user can turn the buzzer off or set it to sound every time the label is saved. It can also be set to sound every time a label is read, but this will result in a reduction in the efficiency of multi-tag recognition. This feature is more Is applied in the test label or reader occasion The operation interface is as follows: It should be noted that the success of the self-test after the buzzer sound is not controlled by this 18 Eximia Srl -
19 setting. After setting, the state of the buzzer will keep the FLASH inside and outside the reader, after the power is not lost 2. Develop your own RFID application Users can use the demo program to operate most of the functions of the reader, but in the actual application environment, it is necessary to develop the user's own program The accompanying documentation: UHF_RFID serial interface communication protocol _V2.38.pdf provides a complete interface for operating the reader. This interface is based on serial communication, so regardless of the user's physical interface is RS or TCP / IP, the reader is to follow the definition of this interface Demonstration program provides an important function is the serial port transmission records, the user with the communication protocol documentation and demo program operation process of the actual serial data to compare, you can quickly grasp the contents of the communication protocol Select the lower right corner of the open serial port monitoring check box, all the uplink and downlink serial data will be recorded, as shown below (open the serial port monitoring, the software response speed will slow down, so usually should close the serial port monitoring.: 19 Eximia Srl -
20 Red information for the software to send the data, black information for the UHF module to return to the software data. Which manually send data function, for users to debug serial port command to use, it has automatically calculated check sum function. In addition, the accompanying documentation also includes the complete source code for this demo program for user reference, so that applications based on this handheld device can be quickly developed 20 Eximia Srl -
INDY R2000 Module Series Specification
1 Table 1: Module Overview Module Type M-2600 M-2800 Real Photo RF Channel Single Channel Four channel RF Connector MMCX SMA Antenna Connection Mode Can be configured as a single Bistatic is unavailable
More informationWJM1000. Next Generation RFID Reader Module Based on the WJC200 Gen2 RFID reader chipset. Key Features
Key Features Multi-protocol support: ISO 18000-6C (Gen2) & ISO 18000-6B Dynamic RF output power: 10dBm to 24dBm range Two antenna ports for added flexibility Special high performance single tag access
More informationLC-10 Chipless TagReader v 2.0 August 2006
LC-10 Chipless TagReader v 2.0 August 2006 The LC-10 is a portable instrument that connects to the USB port of any computer. The LC-10 operates in the frequency range of 1-50 MHz, and is designed to detect
More informationTC-2600A RFID Tester
TC-2600A RFID Tester Integration of All required Functions for Reader and Tag Testing Into a Single Unit Supports 860MHz ~ 960MHz UHF RFID Supports ISO/IEC 18000-6 Air Interface Protocol Reader and Tag
More informationSPS1M-EVK. SPS1M-EVK Battery Free Wireless Sensor Handheld Evaluation System EVAL BOARD USER S MANUAL
SPS1M-EVK SPS1M-EVK Battery Free Wireless Sensor Handheld Evaluation System EVAL BOARD USER S MANUAL Introduction This guide describes how to use the Handheld Evaluation System to carry out sensor measurements
More informationPROMAG RWM600A. ISO/IEC15693 Advanced Reader Module. Overview. Features. Application. Specifications. Application Circuit
Overview ISO569 reader module works with smart label, based on transponders with an operating frequency of.56mhz (e.g. I-CODE SL, Tag-It HF-I etc.), based on TI-RFID technology. Depending on the size of
More informationST600 TRANSMITTER OPERATING INSTRUCTIONS
ST600 TRANSMITTER OPERATING INSTRUCTIONS 1892 1273 These operating instructions are intended to provide the user with sufficient information to install and operate the unit correctly. The Wood and Douglas
More informationIntegration of All Required Functions for Reader and Tag Testing into a single unit Supports 840 MHz ~ 960 MHz UHF RFID Supports ISO/IEC Air
Integration of All Required Functions for Reader and Tag Testing into a single unit Supports 840 MHz ~ 960 MHz UHF RFID Supports ISO/IEC 18000-6 Air Interface Protocol Reader and Tag Emulator Functions
More informationPassive Sensors Technical Guide
Application Note Version 1.0 10/17/2016 This document is a technical user guide to the working principles and usage of Smartrac passive sensor products using RF Micron Magnus S2 and S3 ICs. 1. INTRODUCTION...
More information1 UAT Test Procedure and Report
1 UAT Test Procedure and Report These tests are performed to ensure that the UAT Transmitter will comply with the equipment performance tests during and subsequent to all normal standard operating conditions
More informationA step-by-step process for attaching a photo of the park through Android Mobile Application
A step-by-step process for attaching a photo of the park through Android Mobile Application Feedback is registered by the customer with the details of the customer and park through web based enabled application
More informationSV613 USB Interface Wireless Module SV613
USB Interface Wireless Module SV613 1. Description SV613 is highly-integrated RF module, which adopts high performance Si4432 from Silicon Labs. It comes with USB Interface. SV613 has high sensitivity
More informationDragonLink Advanced Transmitter
DragonLink Advanced Transmitter A quick introduction - to a new a world of possibilities October 29, 2015 Written by Dennis Frie Contents 1 Disclaimer and notes for early release 3 2 Introduction 4 3 The
More informationApplication Note: IQ Filtering in an RFID Reader Using Anadigm Integrated circuits,
Application Note: IQ Filtering in an RFID Reader Using Anadigm Integrated circuits, Rev: 1.0.3 Date: 3 rd April 2006 We call this multi-chip circuit solution RangeMaster3, It uses Anadigm s. RangeMaster2
More informationTechnical Documentation
Technical Documentation for metratec UHF Field Analyser Date: November 2014 Version: 01.00 Technical Documentation metratec UHF Field Analyser Page 1 of 10 Table of Contents 1 General Information...3 1.1
More informationMINIMUM SYSTEM REQUIREMENTS
Quick Start Guide Copyright 2000-2012 Frontline Test Equipment, Inc. All rights reserved. You may not reproduce, transmit, or store on magnetic media any part of this publication in any way without prior
More informationSuitable firmware can be found on Anritsu's web site under the instrument library listings.
General Caution Please use a USB Memory Stick for firmware updates. Suitable firmware can be found on Anritsu's web site under the instrument library listings. If your existing firmware is older than v1.19,
More informationQuick Start Guide for the PULSE PROFILING APPLICATION
Quick Start Guide for the PULSE PROFILING APPLICATION MODEL LB480A Revision: Preliminary 02/05/09 1 1. Introduction This document provides information to install and quickly start using your PowerSensor+.
More informationInstruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1
Instruction Manual ABM HART Gateway Software Instruction Manual Revision A.1 Table of Contents Section 1: Getting Started... 3 1.1 Setup Procedure... 3 1.2 Quick Setup Guide for Ultrasonic Sensors... 11
More informationHytera. PD41X Patrol Management System. Installation and Configuration Guide
Hytera PD41X Patrol Management System Installation and Configuration Guide Documentation Version: 01 Release Date: 03-2015 Copyright Information Hytera is the trademark or registered trademark of Hytera
More informationGetting Started with TrangoLink
Getting Started with TrangoLink Overview: TrangoLink allows you to configure and monitor your EAGLE PLUS, FALCON, or PTZ-900 transmitters and receivers. On the EAGLE PLUS and FALCON transmitters, you can
More informationDual-band radio transmitter T10, Т10С T10U, T10UC
Dual-band radio transmitter T10, Т10С T10U, T10UC (v.yymmdd) Installation manual www.trikdis.com 1 Contents Safety requirements... 3 Transmitter function... 3 Operation... 3 Outside view... 4 Installation...
More informationWPE 48N USER MANUAL Version1.1
Version1.1 Security instructions 1. Read this manual carefully. 2. Follow all instructions and warnings. 3. Only use accessories specified by WORK PRO. 4. Follow the safety instructions of your country.
More informationDATE: 17/08/2006 Issue No 2 e-plate Operation Overview
Page 1 of 7 Fundamentals Introduction e-pate technology is the next generation of long range RFID (Radio Frequency IDentification). The objective is wireless and automated data collection of vehicles and
More informationCatalog
- 1 - Catalog 1. Description...- 3-2. Features...- 3-3. Applications... - 3-4. Block Diagram...- 3-5. Electrical Characteristics... - 5-6. Operation... - 5 - Power on Reset... - 5 - Working mode... - 6
More informationDRG-Series. Digital Radio Gateway. Motorola MotoTRBO DMR. Interfacing Omnitronics DRG with Motorola MotoTRBO DMR Digital Radios
DRG-Series Digital Radio Gateway Motorola MotoTRBO DMR Interfacing Omnitronics DRG with Motorola MotoTRBO DMR Digital Radios Digital Radio Supplement DRG-Series Supplement Interfacing Omnitronics DRG with
More informationPhysical Inventory System User Manual. Version 19
Physical Inventory System User Manual Version 19 0 Physical Inventory System User Manual 1 Table of Contents 1. Prepare for Physical Inventory... 2. Chapter 1: Starting Inventory... 2.1. CDK/ADP... 3.
More informationTable of Contents. Chapter 1: Software Installation...1. Chapter 2: Running the Software II. Daily Practical Operation...10
Product Manual Table of Contents Chapter 1: Software Installation.................................1 Chapter 2: Running the Software............................... 2 I. The Initial Defining in Lock Management
More informationID Photo Processor. Batch photo processing. User Guide
ID Photo Processor Batch photo processing User Guide 2015 Akond company 197342, Russia, St.-Petersburg, Serdobolskaya, 65a Phone/fax: +7(812)384-6430 Cell: +7(921)757-8319 e-mail: info@akond.net http://www.akond.net
More informationTechnical Note #15. Radio Frequency Modems. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home
1 of 5 GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home GE Power Management Control System Description Software Hardware Operation Product Support Operator Interfaces F A Q s App
More informationIT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual
IT-24 RigExpert 2.4 GHz ISM Band Universal Tester User s manual Table of contents 1. Description 2. Specifications 3. Using the tester 3.1. Before you start 3.2. Turning the tester on and off 3.3. Main
More informationtechnical report MHz ISM Band Class 1 Radio Frequency Identification Tag Interface Specification: Recommended Standard, Version 1.0.
technical report 13.56 MHz ISM Band Class 1 Radio Frequency Identification Tag Interface Specification: Recommended Standard, Version 1.0.0 Auto-ID Center auto-id center massachusetts institute of technology,
More informationCAD-MF. PC-Based Multi-Format ANI & Emergency ANI Display Decoder. Manual Revision: Covers Firmware Revisions: CAD-MF: 1.
CAD-MF PC-Based Multi-Format ANI & Emergency ANI Display Decoder Manual Revision: 2010-05-25 Covers Firmware Revisions: CAD-MF: 1.0 & Higher Covers Software Revisions: CAD: 3.21 & Higher Covers Hardware
More informationManaging Radios and Radio Descriptors
CHAPTER9 The Cisco IPICS administrator is responsible for configuring the radios and radio descriptors that are used with Cisco IPICS. This chapter provides detailed information about managing these items.
More informationPC Tune PC Tune Test Procedures for 5100 Series Portable Radios
PC Tune PC Tune Test Procedures for 5100 Series Portable Radios Part Number 002-9998-6513014 August 2008 Copyright 2006, 2007, 2008 by EFJohnson Technologies The EFJohnson Technologies logo, PC Configure,
More informationReader Configuration. Configuration Parameters for UHF RFID Reader DTE800 / DTE810 DTE900 / DTE910. Version 1.00
Reader Configuration Configuration Parameters for UHF RFID Reader DTE800 / DTE810 DTE900 / DTE910 Version 1.00 2010 ifm electronic 28.10.2010 The UHF RFID reader system is characterised by great fl exibility
More informationAcuMesh Wireless RS485 Network. User's Manual SOLUTION
AcuMesh Wireless RS485 Network User's Manual AN SOLUTION ACUMESH - WIRELESS METERING SYSTEM COPYRIGHT 2015 V1.2 This manual may not be altered or reproduced in whole or in part by any means without the
More informationEcoGreen Singapore RFID Products Catalogue
RFID Products Catalogue EcoGreen-SG ( RFID ID Badge & Security System ) Shenzhen EcoGreen Rm.1518,International Culture Building,No.3039, Shen Nan Zhong Road, Futian District, ShenZhen, P.R. China. ( 深圳市深南中路
More informationMPR kHz Reader
MPR-5005 Page 1 Doc# 041326 MPR-5005 125kHz Reader Installation & Operation Manual - 041326 MPR-5005 Page 2 Doc# 041326 COPYRIGHT ACKNOWLEDGEMENTS The contents of this document are the property of Applied
More informationCatalogue
- 1 - Catalogue 1. Description... - 3-2. Features... - 3-3. Applications...- 3-4. Block Diagram... - 3-5. Electrical Characteristics...- 4-6. Operation...- 5 - Power on Reset... - 5 - Working mode... -
More informationTEK-TROL HART GATEWAY SOFTWARE. Operating Instruction Manual.
TEK-TROL HART GATEWAY SOFTWARE Operating Instruction Manual www.tek-trol.com Table of Contents 1 Getting Started... 2 1.1 Setup Procedure... 2 1.2 Quick Setup Guide for Radar Sensors... 10 2 Level device
More informationGPRS-A. Universal monitoring module. Firmware version 1.00 gprs-a_en 04/18
GPRS-A Universal monitoring module Firmware version 1.00 gprs-a_en 04/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. +48 58 320 94 00 www.satel.eu WARNINGS The module should be installed
More informationG3P-R232. User Manual. Release. 2.06
G3P-R232 User Manual Release. 2.06 1 INDEX 1. RELEASE HISTORY... 3 1.1. Release 1.01... 3 1.2. Release 2.01... 3 1.3. Release 2.02... 3 1.4. Release 2.03... 3 1.5. Release 2.04... 3 1.6. Release 2.05...
More informationCatalog
- 1 - Catalog 1. Overview...- 3-2. Feature... - 3-3. Application...- 3-4. Block Diagram...- 3-5. Electrical Characteristics... - 4-6. Operation... - 4-1) Power on Reset... - 4-2) Sleep mode... - 4-3) Working
More informationSV-MESH Mesh network series Catalogue
Catalogue 1. Description... 3 2. Features... 3 3. Applications... 3 4. Block Diagram... 4 5. Electrical Characteristics... 5 6. Operation... 5 Power on Reset... 5 Working mode... 6 Router mode... 8 Setting
More informationDataCAD Softlock License Activation and Management
DataCAD Softlock License Activation and Management DataCAD uses a software-based license management technology called a softlock, in lieu of the hardware-based USB key, or hardlock used by older versions.
More informationTRANSCEIVER FSK. Version: 434 MHz Band / 868 MHZ Band / Code: / A
TRANSCEIVER FSK Version: 434 MHz Band / 868 MHZ Band / Code: 3-2000519 / 3-2000519A DESCRIPTION: The 3-2000519 and 3-2000519A modules are fully programmable multichannel PLL based FSK transceivers, with
More informationUHF RFID Integrated Reader. Software operation manual
Stronglink SL130 Software Operation Manual UHF RFID Integrated Reader Software operation manual Content Software operation manual 1 Content 1 C O N T E N T.......................................................
More informationISO/IEC INTERNATIONAL STANDARD
INTERNATIONAL STANDARD This is a preview - click here to buy the full publication ISO/IEC 24769-5 First edition 2012-12-15 Corrected version 2012-12-15 Information technology Automatic identification and
More informationGround System Training Department
Module 7: IPSTAR Uplink Access Test (IUAT) Ground System Training Department 2012-03-Standard (iuat1.14)-uti-101 THAICOM Public Company Limited Module Objectives At the end of the module the participant
More informationDRG-Series. Digital Radio Gateway. Kenwood NXDN Donor Radio (Tier-2) Interfacing Omnitronics DRG with Kenwood NXDN Donor Digital Radios (Tier-2)
DRG-Series Digital Radio Gateway Kenwood NXDN Donor Radio (Tier-2) Interfacing Omnitronics DRG with Kenwood NXDN Donor Digital Radios (Tier-2) Digital Radio Supplement DRG-Series Supplement Kenwood NXDN
More informationDataCAD 18 Softlock. Universal Installer. Installation. Evaluation
DataCAD 18 Softlock DataCAD 18 uses a software-based license management option, referred to as a softlock, in lieu of the hardware-based USB license key, or hardlock used by older versions. Each DataCAD
More informationinstruction manual for Open LRS New Generation
instruction manual for Open LRS New Generation Table of contents 1. Important warnings 2. Hardware Overview 3 2.1 DTF UHF 4 Channel 4 2.2 HobbyKing RX 5 3. Instructions 3.1 Basic functions 6 3.2 Flashing
More informationGuardian and DL3282 Modem Interface Technical Service Application Note
Guardian and DL3282 Modem Interface Technical Service Application Note OVERVIEW The following document is designed to provide information for the implementation of the Guardian Wireless Modem/Analog Radio
More informationCommunication with FCC s Office of Engineering Technology Regarding ISM Compliance of Power-Optimized Waveforms
Communication with FCC s Office of Engineering Technology Regarding ISM Compliance of Power-Optimized Waveforms Document ID: PG-TR-081120-GDD Date: 11 November 2008 Prof. Gregory D. Durgin 777 Atlantic
More informationCoin vending controller
Coin vending controller Bluetooth For water Vending machine For Model No. ECA4058 Introduction ECA 4058 is a coin vending controller. It is used in water vending machines. We can use JY926 or ICT UCA2
More informationRF4432 wireless transceiver module
1. Description www.nicerf.com RF4432 RF4432 wireless transceiver module RF4432 adopts Silicon Lab Si4432 RF chip, which is a highly integrated wireless ISM band transceiver. The features of high sensitivity
More informationModel OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL
Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL The features mentioned in this Advanced OT-1000-HH Manual can be accessed only with the optional OT-NEC-A, Network Element
More informationPolitecnico di Milano Advanced Network Technologies Laboratory. Radio Frequency Identification
Politecnico di Milano Advanced Network Technologies Laboratory Radio Frequency Identification RFID in Nutshell o To Enhance the concept of bar-codes for faster identification of assets (goods, people,
More informationEDACS SYSTEM MANAGER. User s Guide. Mobile Communications. User s Guide For Version 3.XX (Group 3) LBI-38984
Mobile Communications EDACS SYSTEM MANAGER (Enhanced Digital Access Communications System) User s Guide For Version 3.XX (Group 3) User s Guide TABLE OF CONTENTS Page Section/Paragraph INTRODUCTION..................................................
More informationMastr III P25 Base Station Transmitter Tune-up Procedure
Mastr III P25 Base Station Transmitter Tune-up Procedure 1. Overview The Mastr III Base Station transmitter alignment is performed in several steps. First, the Transmit Synthesizer module is aligned to
More informationWireless sensor system
Wireless sensor system Internet / Ounet PC in internal network GW Internet connection FIGURE 1 structure of wireless sensor network = Base station = Routing wireless sensor = Wireless sensor General description
More informationDRG-Series. Digital Radio Gateway. Hytera DMR USB Donor (Tier-2) Digital Radio Supplement
DRG-Series Digital Radio Gateway Hytera DMR USB Donor (Tier-2) Digital Radio Supplement DRG-Series Digital Radio Gateway Hytera DMR USB Donor (Tier-2) Digital Radio Supplement 2015 Omnitronics Pty Ltd.
More informationinphoto ID Canon and Olympus camera control software Automatic ID photography User Guide
inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide 2006 Akond company 197342, Russia, St.-Petersburg, Serdobolskaya, 65a Phone/fax: +7(812)600-6918 Cell: +7(921)757-8319
More informationPressure Field Unit User Guide
Rev. 0605 Pressure Field Unit User Guide A Division of Adaptive Instruments Corp. 577 Main Street Hudson, MA 01749 U.S.A. TEL: 800-879-6576 978-568-0500 FAX: 978-568-9085 Email: support@accutechinstruments.com
More informationInventory Manual. Version 3. Hart ID = Have a question? Call Hart Client Care at , or us at
Version 3 Hart ID = 924-01 Inventory Manual Review Equipment & Supplies page 2 About Hart Scanners page 4 Register Scanners page 6 Place Fixture Stickers page 8 Enter Sticker Ranges page 14 Scanning Basics
More informationChaos Communication Camp Milosch Meriac Henryk Plötz
Chaos Communication Camp 2007 Milosch Meriac Henryk Plötz meri@openpcd.org henryk@ploetzli.ch Chaos Communication Camp 2007 2007-08-10 (1/30) CCCamp2007 2007-08-10 international standard for Proximity
More informationRadio Frequency Identification
Radio Frequency Identification Retail item level Radio Frequency Tagging Market size: >1 Trillion die/year (Retail, item tags) Economic impact 5% of sales lost due to not on shelf 5-15% of some items stolen
More informationFederal Communications Commission Office of Engineering and Technology Laboratory Division
April 9, 2013 Federal Communications Commission Office of Engineering and Technology Laboratory Division Guidance for Performing Compliance Measurements on Digital Transmission Systems (DTS) Operating
More informationDRG-Series. Digital Radio Gateway. Tait P25 CCDI Tier-2 (TM9400 Series Mobile Radio) Digital Radio Supplement
DRG-Series Digital Radio Gateway Tait P25 CCDI Tier-2 (TM9400 Series Mobile Radio) Digital Radio Supplement DRG-Series Digital Radio Gateway Tait P25 CCDI Tier-2 (TM9400 Series Mobile Radio) Digital Radio
More informationRFID Door Unlocking System
RFID Door Unlocking System Evan VanMersbergen Project Description ETEC 471 Professor Todd Morton December 7, 2005-1- Introduction In this age of rapid technological advancement, radio frequency (or RF)
More informationTOSHIBA MACHINE CO., LTD.
User s Manual Product SHAN5 Version 1.12 (V Series Servo Amplifier PC Tool) Model SFV02 July2005 TOSHIBA MACHINE CO., LTD. Introduction This document describes the operation and installation methods of
More informationGPRS-T2. GPRS/SMS Reporting Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel
GPRS/SMS Reporting Module GPRS-T2 Program version 1.0 gprs-t2_en 11/08 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl WARNINGS The module should
More informationVisorTrac A Tracking System for Mining
VisorTrac A Tracking System for Mining Marco North America, Inc. SYSTEM APPLICATION The VISORTRAC system was developed to allow tracking of mining personnel as well as mining vehicles. The VISORTRAC system
More informationGV-RU9003 UHF RFID Reader
GV-RU9003 UHF RFID Reader Introduction GV-RU9003 is a Radio Frequency Identification (RFID) reader of ISO18000-6C (EPC GEN2) standard. Designed for parking lot management, the reader can read RFID tag
More informationSINGLE PHASE STS PREPAID METER
SINGLE PHASE STS PREPAID METER Table of Contents 1 INTRODUCTION... 2 2 STANDARDS REFERENCES... 3 3 TECHNICAL PARAMETERS... 3 3.1 Meter operating voltage... 3 3.2 Meter current parameters... 3 3.3 Meter
More informationR&S RTO-K92 emmc Compliance Test Test Procedures
R&S RTO-K92 emmc Compliance Test Test Procedures (=Q3Þ2) Test Procedures 1333.0380.02 03 This manual describes the emmc compliance test procedures with the following options: R&S RTO-K92 (1329.6958.02)/(1333.0444.02)
More informationPROGRAMMING MANUAL PCCONFIGURE SOFTWARE. December 2004 Part No
PROGRAMMING MANUAL PCCONFIGURE PROGRAMMING SOFTWARE December 2004 Part No. 002-9998-488 11 PCCONFIGURE PROGRAMMING SOFTWARE USER MANUAL This manual covers PCConfigure Versions through 1.26.0. Copyright
More informationFirmware version 1.05 supports all CMOS sensor based digital backs IQ150, IQ250 and A- series IQ250.
RELEASE NOTE January, 2015 Firmware version 1.05 for IQ150, IQ250 and A-series IQ250 Firmware version 1.05 supports all CMOS sensor based digital backs IQ150, IQ250 and A- series IQ250. New functionality
More informationOEM 100. User Manual. Figure 1: OEM 100 Module with HG Rectangular Antenna Board
OEM 100 User Manual Figure 1: OEM 100 Module with HG Rectangular Antenna Board Revision History Revision History Release Version Date Revision Description Authors Version 1.0 07/20/09 Initial Release Bryan
More informationAN797 WDS USER S GUIDE FOR EZRADIO DEVICES. 1. Introduction. 2. EZRadio Device Applications Radio Configuration Application
WDS USER S GUIDE FOR EZRADIO DEVICES 1. Introduction Wireless Development Suite (WDS) is a software utility used to configure and test the Silicon Labs line of ISM band RFICs. This document only describes
More informationSupply 12Vdc nominal (9 Vdc minimum, 14,5Vdc maximum ) Max Current Drain. from a , V Carrier Frequency
MIX400 48 CHANNELS WIRELESS RECEIVER ON 8 OUTPUTS TECHNICIAN MANUAL ENGLISH DESCRIPTION Mix 400 is a 48 channel universal wireless receiver, memorizable and free assignable on 8 open-collector outputs.
More informationWireless Howto. Rev 9
Wireless Howto Rev 9 The Overdrive System can use radio modems to communicate between the Control Computer ( CC ) and the Embedded Computer ( EC ). The modem manufacturer is Cirronet (GA, USA). The model
More informationBlue Bamboo P25 Device Manager Guide
Blue Bamboo P25 Device Manager Guide Version of Device Manager: 1.1.28 Document version: 2.3 Document date: 2011-09-20 Products: P25 / P25-M / P25i / P25i-M BLUE BAMBOO Headquarters Blue Bamboo Transaction
More informationField Software Notice
To: Subject: Field Software Notice Users of 5100 ES, 51SL ES and Ascend ES Portable Radios Software Release Platform: 5100 ES Portable Protocol: All Version Release #: 6.14.5 (part number 039-5757-222)
More informationYou should see the following screen when you first login to Student E-Service
You should see the following screen when you first login to Student E-Service Check your status at the top of the screen. It should read Ready to Register Online You will find useful information in the
More informationAirScope Spectrum Analyzer User s Manual
AirScope Spectrum Analyzer Manual Revision 1.0 October 2017 ESTeem Industrial Wireless Solutions Author: Date: Name: Eric P. Marske Title: Product Manager Approved by: Date: Name: Michael Eller Title:
More informationArduino Lesson 1. Blink. Created by Simon Monk
Arduino Lesson 1. Blink Created by Simon Monk Guide Contents Guide Contents Overview Parts Part Qty The 'L' LED Loading the 'Blink' Example Saving a Copy of 'Blink' Uploading Blink to the Board How 'Blink'
More information5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version valontechnology.com
5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version 1.6.1 valontechnology.com 5008 Dual Synthesizer Module Configuration Manager Program Version 1.6.1 Page 2 Table of Contents
More informationBCV-1203 Barcode Verification System Users Guide Version 1.2
BCV-1203 Barcode Verification System Users Guide Version 1.2 6 Clock Tower Place Suite 100 Maynard, MA 01754 USA Tel: (866) 837-1931 Tel: (978) 461-1140 FAX: (978) 461-1146 http://www.diamondt.com/ Liability
More informationDesign of UHF RFID Emulators with Applications to RFID Testing and Data Transport
Design of UHF RFID Emulators with Applications to RFID Testing and Data Transport Rich Redemske MIT AutoID Lab Cambridge, MA, USA redemske@mit.edu Rich Fletcher TagSense, Inc. Cambridge, MA, USA rf@tagsense.com
More informationRemote Switching. Remote Gates. Paging.
Features Miniature RF Receiver and Decoder. Advanced Keeloq Decoding Advanced Laser Trimmed Ceramic Module AM Range up to 100 Metres FM Range up to 150 Metres Easy Learn Transmitter Feature. Outputs, Momentary
More informationINDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6
ST-965 VX/D SMARTRUNK II & SMARTRUNK XPRESS Logic board Programming Software 2.9e User s Guide Revision R2.9 10/10/2008 INDEX INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3
More informationCOMPACONLINE CARD MANAGEMENT MANUAL
COMPACONLINE CARD MANAGEMENT MANUAL CompacOnline Card Management Version No: 1.0.1 Date: 20/04/2018 Document Control Document Information Document Details Current Revision Author(s) Authorised By CompacOnline
More informationContrail TDMA Manager User s Reference
Contrail TDMA Manager User s Reference VERSION 6 Published: May 2018 =AT Maintenance Report Understanding Contrail TDMA Terminology i Contents Chapter 1: Understanding Contrail TDMA Terminology... 3 General
More informationMAXI Remote Location Kit MRLK 900 Installation and Configuration Manual
MAXI Remote Location Kit MRLK 900 Installation and Configuration Manual 01/18 635079 Table of Contents Introduction... 3 Materials Included... 3 Setup Overview... 4 Radio Configuration Overview:... 4 FreeWaveTool
More informationMicro Fox PicCon Manual
Micro Fox PicCon Manual Version 0.61 The Micro Fox PicCon (MF PC) is a 700mW fox hunting/hidden transmitter hunt transceiver. It can be configured and remotely controlled via DTMF tones, and also be configured
More informationRFID Multi-hop Relay Algorithms with Active Relay Tags in Tag-Talks-First Mode
International Journal of Networking and Computing www.ijnc.org ISSN 2185-2839 (print) ISSN 2185-2847 (online) Volume 4, Number 2, pages 355 368, July 2014 RFID Multi-hop Relay Algorithms with Active Relay
More informationivu Plus Quick Start Guide P/N rev. A -- 10/8/2010
P/N 154721 rev. A -- 10/8/2010 Contents Contents 1 Introduction...3 2 ivu Plus Major Features...4 2.1 Demo Mode...4 2.2 Sensor Types...4 2.2.1 Selecting a Sensor Type...5 2.3 Multiple Inspections...6 2.3.1
More informationConfiguration of the Pacific Crest Radios using PDLCONF software PDL Base Radio
Configuration of the Pacific Crest Radios using PDLCONF software PDL Base Radio This document will guide user s through configuration of the PDL Base Radio. Required items: PDL Base Radio, PDL Config software,
More information