AIXUV's Tools for EUV-Reflectometry Rainer Lebert, Christian Wies AIXUV GmbH, Steinbachstrasse 15, D Aachen, Germany
|
|
- Todd Roberts
- 6 years ago
- Views:
Transcription
1 AIXUV's Tools for EUV-Reflectometry Rainer Lebert, Christian Wies, Steinbachstrasse 5, D-, Germany and partners developed several tools for EUV-reflectometry in different designs for various types of applications. The range of tools is starting with the affordable, flexible, and compact reflectometers for laboratory use (CEUVR) and is including the high end fully automated high speed reflectometer for EUV mask blanks (MBR) that is fully compliant with the SEMI-standard P38 for EUV mask blank metrology and suited for daily in-fab use. In this paper the different concepts will be discussed and the performance of the systems will be presented. The paper will focus on the upgrades of the mask blank reflectometer for being used on structured masks including smaller spot size as well as improved accuracy and precision. The compliance with the ITRS metrology roadmap is discussed. The work was partially founded by the German Bundesministerium für Bildung und Forschung (BMBF).
2 Polychromatic EUV Reflectometry (Spectrophotometry) Grating CCD-Camera In our tools, we apply Polychromatic Spectrophotometry : EUV-Source Aperture (Virtual) Entrance Slit The whole EUV-spectrum is, spectrally dispersed and detected by a CCD. This allows for minimized measuring spot, high throughput with high numbers of spectral channels and highest DQE. Advantages: Most effective use of photons emitted from the The set-up is stationary With a CCD camera: brilliant DQE and Side-information (scatter, geometry) is obtained The whole spectral reflectance curve is measured simultaneously. Hence, measuring 2000 spectral channels can be accomplished with less than 00 pulses. Measuring system is mechanically stable. With reference mirrors any fluctuations do not influence the relative results. With plasma source wavelength calibration with emission lines is immanent, Disadvantages: Instead of a diode: CCD camera: evaluation. Data transfer from the CCD limits the throughputs. Polychromatic Photometry offers the most effective approach for characterizing spectral reflection, transmission, absorption, scatter etc.
3 EUV-Reflectometer designed for EUV Mask Blanks (MBR) Parameter: Spectral resolution Wavelength calibration: Wavelength reproducibility Measuring spot size Measuring spectral range Time for one spot best quality Angle of incidence reproducibility Absolute accuracy (MADT) Reproducibility of reflectance MBR typical.6 pm ± < 2 pm ± < pm < 00 µm mm.8 to 4.9 nm (2048 channels) 20 s < 00 µrad < 0.5 % absolute < 0. % RMS Reflectance Increment < % Minimum Reflectance Capability < 0. % Dedicated for SEMI compatible Qualification of EUV Mask Blanks (extendable to EUV-Masks, due to extremely small spot and high throughput)
4 MBR: Three Spectra are Measured in Comparison 0000 R = R Cal Signal * Signal CAL@ Calibration Signal Signal Reference@ Calibration Reference@ Measurement CCD Ref Ref 2 Grating Slit Schematic of comparative measurement with reference mirrors Wavelength ( nm in 2048 channels) NB Reference Typical raw CCD-result BB Reference nm Average Counts per Pixel Ref Ref2 Signal, a.u CCD PIXEL number measured spectrum NIST Identified Xe-Lines Dispersion Linear (Dispersion) Spectral Channel Three samples are measured simultaneously with high dynamics y = x R 2 = WL(963) = (3.507 ± ) nm Dispersion := (.576 pm ± 5 fm) /PIXEL Wavelength, nm Immanent wavelength calibration with Xe-emission lines
5 High Reproducibility and Sensitivity R eflectan ce 70% 60% 50% 40% 30% 20% 0% 0% R e fle c ta n c e 3.7% 3.5% 3.3% 3.% 2.9% 2.7% 2.5% Wavelength, nm Layer deviation off-center is detected Peak reflectance = % ± 0.05 % Central wavelength = nm ± 0.4 pm WL of peak FWHM = nm ± 0.8 pm = nm ± 0.4 pm R e fle c ta n c e Wavelength, nm 70.4% 70.3% 70.2% 70.% 70.0% 69.9% 69.8% 69.7% 69.6% R = 0.06 % λ = 8 pm R = 0. % λ = 0 pm 69.5% Wavelength, nm R = 0.55 % λ = 2 pm Off-center results demonstrate Sensitivity b c d Center measurements (with movement after 5) overlaid
6 Absorber Measurements (Down to Substrate).2% 0.00% % 0.009% 0.008% 000 reflectance 0.8% 0.6% 0.4% Reflectance 0.007% 0.006% 0.005% 0.004% 0.003% 00 0 Signals, av. counts per pixel row CXRO_Reflectance REFLECTANCE SIGNAL Substrate SIGNAL Reference 0.2% 0.002% 0.00% 0.0% wavelength [nm] Typical 5 measurements on Absorber overlaid 0.000% Wavelenght, nm Reflectance measurement on uncoated substrate 0000 Peak reflectance =.087 % ± % 9000 Central wavelength = nm ±. pm FWHM = nm ± 2.3 pm 4 bit dynamics is usable Signal Substrate: av. counts per pixel row Signal Broadband: av. counts per pixel row SIGNAL Braodband Signal Substrate Substrate Spectra are of > /0000 contrast to Reference Signals of same measurement and significant to < 0.2 counts (as averaged over 200 pixel columns) Wavelenght, nm Signals from Reference and Substrate compared
7 CPR: Compact Polychromatic R&D Reflectometer Parameter: CPR typical Spectral resolution 0 pm Wavelength calibration: ± < 0 pm Wavelength reproducibility ± < 0 pm Measuring spot size < 00 µm mm Measuring spectral range 0 to 6 nm (024 ch) Time for one spot best quality 5 s (LAMP) 0 min (Tube) Absolute accuracy (MADT) < % absolute Reproducibility of reflectance < 0.5 % RMS Reflectance Increment < 0.02 % Minimum Reflectance Capability < 0. %
8 CEUVR: Flexible Spectrophotometer (Reflectance, Transmission, Scatter.) EUV-Source Kirkpatrik-Beaz Spot forming Spectrograph Position for Calibration and Transmission CCD Grating Manipulator Spectrograph Position for Reflectance Rotation Rail SpeXUV
9 Summary AIXUV and our partners can supply a variety of solutions for Spectrophotometry in EUV spectral range. Ranging from dedicated reflectometer for EUV mask-blanks over highly flexible EUV-Spectrophotmeter to economic solution for Coating R&D. Parameter: MBR CEUVR++ CEUVR CPR Spectral resolution, pm.6 20 Wavelength calibration, pm ± < 2 ± < 0 tube) ± < 40(tube) ± < 4(lamp) ± < 20(lamp) Wavelength reproducibility, pm ± < ± < 6 ± < 30 Measuring spot size 50 µm * 2 mm (down to 250 µm) Measuring spectral range, nm 3 (e.g. 2-5) 0 (e.g.8 8) Spectral channels Time for one spot (tube) 0 min 0 min (Lamp) 20 s 20 s Angle of incidence one fixed variable variable one fixed (e.g. 6 ) (0-85 ) (e.g. 6 ) Alignment triangulation manual reproducibility < 00 µrad < 2 mrad Size, mm 50*50 Ø< 400 Ø< 50 Based on experiments we can suggest best adapted solution for your task.
R. Lebert 1, K. Bergmann 2, O. Rosier 3, W. Neff 2, R. Poprawe 2
R. Lebert 1, K. Bergmann 2, O. Rosier 3, W. Neff 2, R. Poprawe 2 1 AIXUV GmbH, Steinbachstrasse 15, D-52074 Aachen, Germany 2 Fraunhofer Institut für Lasertechnik 3 Lehrstuhl für Lasertechnik, RWTH Aachen
More informationNIST EUVL Metrology Programs
NIST EUVL Metrology Programs S.Grantham, C. Tarrio, R.E. Vest, Y. Barad, S. Kulin, K. Liu and T.B. Lucatorto National Institute of Standards and Technology (NIST) Gaithersburg, MD USA L. Klebanoff and
More informationCritical Challenges of EUV Mask Blank Volume Production
Critical Challenges of EUV Mask Blank Volume Production Holger Seitz, Markus Renno, Thomas Leutbecher, Nathalie Olschewski, Helmut Popp, Torsten Reichardt, Ronny Walter, Günter Hess SCHOTT Lithotec AG,
More informationA novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation
A novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation I. Mantouvalou, K. Witte, R. Jung, J. Tümmler, G. Blobel, H. Legall,
More informationSuperconducting Transition-Edge Sensors and Superconducting Tunnel Junctions for Optical/UV Time-Energy Resolved Single-Photon Counters
Superconducting Transition-Edge Sensors and Superconducting Tunnel Junctions for Optical/UV Time-Energy Resolved Single-Photon Counters NHST Meeting STScI - Baltimore 10 April 2003 TES & STJ Detector Summary
More informationDual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE
Dual-FL World's Fastest Fluorometer Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE 100 Times Faster Data Collection The only simultaneous absorbance and fluorescence system available
More informationObservational Astronomy
Observational Astronomy Instruments The telescope- instruments combination forms a tightly coupled system: Telescope = collecting photons and forming an image Instruments = registering and analyzing the
More informationThermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design
TECHNICAL NOTE 43333 Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design Keywords Optical design, Polychromator, Spectrometer Key Benefits The Thermo Scientific icap 7000
More informationAqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN
Aqualog CDOM Measurements Made Easy ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING CDOM measurements
More informationPHYS General Physics II Lab Diffraction Grating
1 PHYS 1040 - General Physics II Lab Diffraction Grating In this lab you will perform an experiment to understand the interference of light waves when they pass through a diffraction grating and to determine
More informationCONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application
CONFIGURING Your Spectroscopy System For PEAK PERFORMANCE A guide to selecting the best Spectrometers, s, and s for your application Spectral Measurement System Spectral Measurement System Spectrograph
More informationPerformance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation
Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Rotation By: Michael Case and Roy Grayzel, Acton Research Corporation Introduction The majority of modern spectrographs and scanning
More informationXUV Research with Compact DPP and LPP Laboratory Sources: Complementary to Beamlines and Large Scale Industrial Tools
XUV Research with Compact DPP and LPP Laboratory Sources: Complementary to Beamlines and Large Scale Industrial Tools Rainer Lebert 1, Christoph Phiesel 1, Thomas Mißalla 1, Christian Piel 1, Alexander
More informationReport on BLP Spectroscopy Experiments Conducted on October 6, 2017: M. Nansteel
Report on BLP Spectroscopy Experiments Conducted on October 6, 2017: M. Nansteel Summary Several spectroscopic measurements were conducted on October 6, 2017 at BLP to characterize the radiant power of
More informationTriVista. Universal Raman Solution
TriVista Universal Raman Solution Why choose the Princeton Instruments/Acton TriVista? Overview Raman Spectroscopy systems can be derived from several dispersive components depending on the level of performance
More informationDetection and application of Doppler and motional Stark features in the DNB emission spectrum in the high magnetic field of the Alcator C-Mod tokamak
Detection and application of Doppler and motional Stark features in the DNB emission spectrum in the high magnetic field of the Alcator C-Mod tokamak I. O. Bespamyatnov a, W. L. Rowan a, K. T. Liao a,
More informationIN-LAB PELLICLE METROLOGY CHALLENGES
IN-LAB PELLICLE METROLOGY CHALLENGES Serhiy Danylyuk RWTH Aachen University 04.10.2015, Maastricht Pellicle requirements Pellicle requirem ent HVM Target EUV transmission 90% single pass Spatial non-uniformity
More informationApplications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region
Feature Article JY Division I nformation Optical Spectroscopy Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region Raymond Pini, Salvatore Atzeni Abstract Multichannel
More informationOn-line spectrometer for FEL radiation at
On-line spectrometer for FEL radiation at FERMI@ELETTRA Fabio Frassetto 1, Luca Poletto 1, Daniele Cocco 2, Marco Zangrando 3 1 CNR/INFM Laboratory for Ultraviolet and X-Ray Optical Research & Department
More informationComparison of actinic and non-actinic inspection of programmed defect masks
Comparison of actinic and non-actinic inspection of programmed defect masks Funded by Kenneth Goldberg, Anton Barty Hakseung Han*, Stefan Wurm*, Patrick Kearney, Phil Seidel Obert Wood*, Bruno LaFontaine
More informationSpectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :
Spectrophotometer An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer : Spectrophotometer components Excitation sources Deuterium Lamp Tungsten
More informationMS260i 1/4 M IMAGING SPECTROGRAPHS
MS260i 1/4 M IMAGING SPECTROGRAPHS ENTRANCE EXIT MS260i Spectrograph with 3 Track Fiber on input and InstaSpec IV CCD on output. Fig. 1 OPTICAL CONFIGURATION High resolution Up to three gratings, with
More informationOptical In-line Control of Web Coating Processes
AIMCAL Europe 2012 Peter Lamparter Web Coating Conference Carl Zeiss MicroImaging GmbH 11-13 June / Prague, Czech Republic Carl-Zeiss-Promenade 10 07745 Jena, Germany p.lamparter@zeiss.de +49 3641 642221
More informationThe only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog
The only simultaneous absorbance and fluorescence system for water quality analysis! Aqualog CDOM measurements made easy. The only simultaneous absorbance and fluorescence system for water quality analysis!
More informationAqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE
Aqualog Water Quality Measurements Made Easy ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING Water
More informationSpectraPro 2150 Monochromators and Spectrographs
SpectraPro 215 Monochromators and Spectrographs SpectraPro 215 15 mm imaging spectrographs and monochromators from are the industry standard for researchers who demand the highest quality data. Acton monochromators
More informationModern UV-curing technology
Spectroradiometry in UV Curing By Lawrence E. Schmutz Figure 1 Absorption spectra for two common photoinitiator families (Spectra reproduced by permission of Sigma-Aldrich Corporation) Modern UV-curing
More informationIon Assisted Deposition Processes for Precision and Laser Optics
Ion Assisted Deposition Processes for Precision and Laser Optics H. Ehlers, T. Groß, M. Lappschies, and D. Ristau Laser Zentrum Hannover e.v. Germany Introduction Ion assisted deposition (IAD) processes
More informationtaccor Optional features Overview Turn-key GHz femtosecond laser
taccor Turn-key GHz femtosecond laser Self-locking and maintaining Stable and robust True hands off turn-key system Wavelength tunable Integrated pump laser Overview The taccor is a unique turn-key femtosecond
More informationECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the
ECEN 4606 Lab 8 Spectroscopy SUMMARY: ROBLEM 1: Pedrotti 3 12-10. In this lab, you will design, build and test an optical spectrum analyzer and use it for both absorption and emission spectroscopy. The
More informationImproving the Collection Efficiency of Raman Scattering
PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution
More informationSpectral Analysis of the LUND/DMI Earthshine Telescope and Filters
Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters 12 August 2011-08-12 Ahmad Darudi & Rodrigo Badínez A1 1. Spectral Analysis of the telescope and Filters This section reports the characterization
More informationQE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers
QE65000 Spectrometer Scientific-Grade Spectroscopy in a Small Footprint QE65000 The QE65000 Spectrometer is the most sensitive spectrometer we ve developed. Its Hamamatsu FFT-CCD detector provides 90%
More informationSpectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation
Spectroscopy in the UV and Visible: Instrumentation Typical UV-VIS instrument 1 Source - Disperser Sample (Blank) Detector Readout Monitor the relative response of the sample signal to the blank Transmittance
More informationMaya2000 Pro Spectrometer
now with triggering! Maya2000 Pro Our Maya2000 Pro Spectrometer offers you the perfect solution for applications that demand low light-level, UV-sensitive operation. This back-thinned, 2D FFT-CCD, uncooled
More informationPreliminary Characterization Results: Fiber-Coupled, Multi-channel, Hyperspectral Spectrographs
Preliminary Characterization Results: Fiber-Coupled, Multi-channel, Hyperspectral Spectrographs Carol Johnson, NIST MODIS-VIIRS Team Meeting January 26-28, 2010 Washington, DC Marine Optical System & Data
More informationDevelopment of scalable laser technology for EUVL applications
Development of scalable laser technology for EUVL applications Tomáš Mocek, Ph.D. Chief Scientist & Project Leader HiLASE Centre CZ.1.05/2.1.00/01.0027 Lasers for real-world applications Laser induced
More informationAqualog. Water Quality Measurements Made Easy FLUORESCENCE
Aqualog Water Quality Measurements Made Easy FLUORESCENCE Water quality measurements made easy The only simultaneous absorbance and fluorescence system for water quality analysis! The new Aqualog is the
More informationSCCH 4: 211: 2015 SCCH
SCCH 211: Analytical Chemistry I Analytical Techniques Based on Optical Spectroscopy Atitaya Siripinyanond Office Room: C218B Email: atitaya.sir@mahidol.ac.th Course Details October 19 November 30 Topic
More informationExperimental Analysis of Luminescence in Printed Materials
Experimental Analysis of Luminescence in Printed Materials A. D. McGrath, S. M. Vaezi-Nejad Abstract - This paper is based on a printing industry research project nearing completion [1]. While luminescent
More informationDESIGN AND CHARACTERIZATION OF A HYPERSPECTRAL CAMERA FOR LOW LIGHT IMAGING WITH EXAMPLE RESULTS FROM FIELD AND LABORATORY APPLICATIONS
DESIGN AND CHARACTERIZATION OF A HYPERSPECTRAL CAMERA FOR LOW LIGHT IMAGING WITH EXAMPLE RESULTS FROM FIELD AND LABORATORY APPLICATIONS J. Hernandez-Palacios a,*, I. Baarstad a, T. Løke a, L. L. Randeberg
More informationCompany synopsis. MSU series
MSU series 1 2 Company synopsis Majantys, part of Pleiades Group along with Pleiades Instruments, is an optoelectronic system maker, designing and manufacturing for specific systems such as photometric
More informationCCD30 11 Back Illuminated High Performance CCD Sensor
CCD30 11 Back Illuminated High Performance CCD Sensor FEATURES * 1024 by 256 Pixel Format * 26 mm Square Pixels * Image Area 26.6 x 6.7 mm * Wide Dynamic Range * Symmetrical Anti-static Gate Protection
More informationSpecifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism
SpectraPro Series Monochromators and Spectrographs The PI/Acton SpectraPro Series imaging spectrographs and monochromators represent the latest advance in the industry-standard SpectraPro family. The SpectraPro
More informationmembrane sample EUV characterization
membrane sample EUV characterization Christian Laubis, PTB Outline PTB's synchrotron radiation lab Scatter from structures Scatter from random rough surfaces Measurement geometries SAXS Lifetime testing
More informationCCD42-10 Back Illuminated High Performance AIMO CCD Sensor
CCD42-10 Back Illuminated High Performance AIMO CCD Sensor FEATURES 2048 by 512 pixel format 13.5 µm square pixels Image area 27.6 x 6.9 mm Wide Dynamic Range Symmetrical anti-static gate protection Back
More informationWavelength stabilized multi-kw diode laser systems
Wavelength stabilized multi-kw diode laser systems Bernd Köhler *, Andreas Unger, Tobias Kindervater, Simon Drovs, Paul Wolf, Ralf Hubrich, Anna Beczkowiak, Stefan Auch, Holger Müntz, Jens Biesenbach DILAS
More informationStable OES System for Fault Detection and Process Monitoring
Stable OES System for Fault Detection and Process Monitoring John D. Corless, K. C. Harvey, Andrew Kueny, Mike Whelan Verity Instruments, Inc. 2901 Eisenhower St. Carrollton, TX 75007 customerservice@verityinst.com
More informationAgilent Cary 7000 Universal Measurement Spectrophotometer (UMS)
Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS) Specifications Introduction The Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS) is designed for superior performance, flexibility
More informationContent Spectrophotometers
Spectroph Content Spectrophotometers Selection table Spectrophotometers Page 163 PRIM Page 164 UviLine Page 166 162 Selection table Spectrophotometers PRIM Light/ PRIM Advanced UviLine 9100/ UviLine 9400
More informationThe FTNIR Myths... Misinformation or Truth
The FTNIR Myths... Misinformation or Truth Recently we have heard from potential customers that they have been told that FTNIR instruments are inferior to dispersive or monochromator based NIR instruments.
More informationDESIGN NOTE: DIFFRACTION EFFECTS
NASA IRTF / UNIVERSITY OF HAWAII Document #: TMP-1.3.4.2-00-X.doc Template created on: 15 March 2009 Last Modified on: 5 April 2010 DESIGN NOTE: DIFFRACTION EFFECTS Original Author: John Rayner NASA Infrared
More informationOptical Design. Instrument concept Foreoptics and slit viewer Spectrograph Alignment plan 3/29/13
Optical Design Instrument concept Foreoptics and slit viewer Spectrograph Alignment plan 3/29/13 3/29/13 2 ishell Design Summary Resolving Power Slit width Slit length Silicon immersion gratings XD gratings
More informationSPECTRAL SCANNER. Recycling
SPECTRAL SCANNER The Spectral Scanner, produced on an original project of DV s.r.l., is an instrument to acquire with extreme simplicity the spectral distribution of the different wavelengths (spectral
More informationMiniature Spectrometer Technical specifications
Miniature Spectrometer Technical specifications Ref: MSP-ISI-TEC 001-02 Date: 2017-05-05 Contact Details Correspondence Address: Email: Phone: IS-Instruments Ltd. Pipers Business Centre 220 Vale Road Tonbridge
More informationSpectroscopic Instrumentation
Spectroscopic Instrumentation Theodor Pribulla Astronomical Institute of the Slovak Academy of Sciences, Tatranská Lomnica, Slovakia Spectroscopic workshop, February 6-10, 2017, PřF MU, Brno Principal
More informationIntroduction to the operating principles of the HyperFine spectrometer
Introduction to the operating principles of the HyperFine spectrometer LightMachinery Inc., 80 Colonnade Road North, Ottawa ON Canada A spectrometer is an optical instrument designed to split light into
More informationSection 1: SPECTRAL PRODUCTS
Section 1: Optical Non-dispersive Wavelength Selection Filter Based Filter Filter Fundamentals Filter at an Incidence Angle Filters and Environmental Conditions Dispersive Instruments Grating and Polychromators
More informationUniversity of Wisconsin Chemistry 524 Spectroscopic Components *
University of Wisconsin Chemistry 524 Spectroscopic Components * In journal articles, presentations, and textbooks, chemical instruments are often represented as block diagrams. These block diagrams highlight
More informationNIRCam optical calibration sources
NIRCam optical calibration sources Stephen F. Somerstein, Glen D. Truong Lockheed Martin Advanced Technology Center, D/ABDS, B/201 3251 Hanover St., Palo Alto, CA 94304-1187 ABSTRACT The Near Infrared
More informationmetcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -
metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 - ACTINIC FLUX SPECTRAL RADIOMETERS Ultra-fast CCD-Detector Spectrometer, UVB enhanced Cooled CCD, 512 pixel *
More informationBasic Components of Spectroscopic. Instrumentation
Basic Components of Spectroscopic Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh 11451 Saudi Arabia
More information2008 European EUVL. EUV activities the EUVL shop future plans. Rob Hartman
2008 European EUVL EUV activities the EUVL shop future plans Rob Hartman 2007 international EUVL Symposium 28-31 October 2007 2008 international EUVL Symposium 28 Sapporo, September Japan 1 October 2008
More informationINTERFEROMETER VI-direct
Universal Interferometers for Quality Control Ideal for Production and Quality Control INTERFEROMETER VI-direct Typical Applications Interferometers are an indispensable measurement tool for optical production
More informationInstructions for the Experiment
Instructions for the Experiment Excitonic States in Atomically Thin Semiconductors 1. Introduction Alongside with electrical measurements, optical measurements are an indispensable tool for the study of
More informationarxiv: v1 [astro-ph.im] 26 Mar 2012
The image slicer for the Subaru Telescope High Dispersion Spectrograph arxiv:1203.5568v1 [astro-ph.im] 26 Mar 2012 Akito Tajitsu The Subaru Telescope, National Astronomical Observatory of Japan, 650 North
More informationBandpass Edge Dichroic Notch & More
Edmund Optics BROCHURE Filters COPYRIGHT 217 EDMUND OPTICS, INC. ALL RIGHTS RESERVED 1/17 Bandpass Edge Dichroic Notch & More Contact us for a Stock or Custom Quote Today! USA: +1-856-547-3488 EUROPE:
More informationMultispectral Image Capturing System Based on a Micro Mirror Device with a Diffraction Grating
Multispectral Image Capturing System Based on a Micro Mirror Device with a Diffraction Grating M. Flaspöhler, S. Buschnakowski, M. Kuhn, C. Kaufmann, J. Frühauf, T. Gessner, G. Ebest, and A. Hübler Chemnitz
More informationEUV Multilayer Fabrication
EUV Multilayer Fabrication Rigaku Innovative Technologies Inc. Yuriy Platonov, Michael Kriese, Jim Rodriguez ABSTRACT: In this poster, we review our use of tools & methods such as deposition flux simulation
More informationCCD67 Back Illuminated AIMO High Performance Compact Pack CCD Sensor
CCD67 Back Illuminated AIMO High Performance Compact Pack CCD Sensor FEATURES * 256 x 256 Pixel Image Area. * 26 mm Square Pixels. * Low Noise, High Responsivity Output Amplifier. * 1% Active Area. * Gated
More informationMarconi Applied Technologies CCD30-11 Inverted Mode Sensor High Performance CCD Sensor
Marconi Applied Technologies CCD30-11 Inverted Mode Sensor High Performance CCD Sensor FEATURES * 1024 by 256 Pixel Format * 26 mm Square Pixels * Image Area 26.6 x 6.7 mm * Wide Dynamic Range * Symmetrical
More informationMulti-wavelength laser scanning architecture for object discrimination.
Research Online ECU Publications Pre. 211 21 Multi-wavelength laser scanning architecture for object discrimination. Kavitha Venkataraayan Sreten Askraba Kamal Alameh Clifton Smith 1.119/HONET.21.5715772
More informationMicro-Mechanical Slit Positioning System as a Transmissive Spatial Light Modulator
Micro-Mechanical Slit Positioning System as a Transmissive Spatial Light Modulator Rainer Riesenberg Institute for Physical High Technology, P.O.Box 100 239, 07702 Jena, Germany ABSTRACT Micro-slits have
More informationSpark Spectral Sensor Offers Advantages
04/08/2015 Spark Spectral Sensor Offers Advantages Spark is a small spectral sensor from Ocean Optics that bridges the spectral measurement gap between filter-based devices such as RGB color sensors and
More informationHistorical. McPherson 15 Mount
McPherson 15 Mount Normal incidence designs include the McPherson 15 (classical 1.0 meter focal length) and modern NIM units. The latter features smaller included angles, longer focal lengths (e.g. 3,
More informationMultispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2
Multispectral imaging device Most accurate homogeneity MeasureMent of spectral radiance UMasterMS1 & UMasterMS2 ADVANCED LIGHT ANALYSIS by UMaster Ms Multispectral Imaging Device UMaster MS Description
More informationCompact EUV Source for Metrology and Inspection
Compact EUV Source for Metrology and Inspection Klaus Bergmann, Jochen Vieker, Alexander von Wezyk 2015 EUV Source Workshop, 10.11.2015, Dublin Overview Introduction Xenon based EUV Source FS5420 Consideration
More informationImage Slicer for the Subaru Telescope High Dispersion Spectrograph
PASJ: Publ. Astron. Soc. Japan 64, 77, 2012 August 25 c 2012. Astronomical Society of Japan. Image Slicer for the Subaru Telescope High Dispersion Spectrograph Akito TAJITSU Subaru Telescope, National
More informationComponents of Optical Instruments
Components of Optical Instruments General Design of Optical Instruments Sources of Radiation Wavelength Selectors (Filters, Monochromators, Interferometers) Sample Containers Radiation Transducers (Detectors)
More informationCHAPTER 7. Components of Optical Instruments
CHAPTER 7 Components of Optical Instruments From: Principles of Instrumental Analysis, 6 th Edition, Holler, Skoog and Crouch. CMY 383 Dr Tim Laurens NB Optical in this case refers not only to the visible
More informationLithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004
Lithography 3 rd lecture: introduction Prof. Yosi Shacham-Diamand Fall 2004 1 List of content Fundamental principles Characteristics parameters Exposure systems 2 Fundamental principles Aerial Image Exposure
More informationINTERNATIONAL INTERCOMPARISON OF WAVELENGTH SCALE AND PHOTOMETRIC SCALE OF SPECTROPHOTOMETRY LABORATORIES CENAM - NRC - INMETRO - NIST.
INTERNATIONAL INTERCOMPARISON OF WAVELENGTH SCALE AND PHOTOMETRIC SCALE OF SPECTROPHOTOMETRY LABORATORIES - - - Arquímedes Ruiz 1, Joanne Zwinkels 2, Iakira Bougleux 3 and Yvonne Barnes 4 1 Optical and
More informationImproved Spectra with a Schmidt-Czerny-Turner Spectrograph
Improved Spectra with a Schmidt-Czerny-Turner Spectrograph Abstract For years spectra have been measured using traditional Czerny-Turner (CT) design dispersive spectrographs. Optical aberrations inherent
More informationSäntis 300 Full wafer cathodoluminescence control up to 300 mm diameter
Säntis 300 Full wafer cathodoluminescence control up to 300 mm diameter Overview The Säntis 300 system has been designed for fully automated control of 150, 200 and 300 mm wafers. Attolight s Quantitative
More informationPhoton Diagnostics. FLASH User Workshop 08.
Photon Diagnostics FLASH User Workshop 08 Kai.Tiedtke@desy.de Outline What kind of diagnostic tools do user need to make efficient use of FLASH? intensity (New GMD) beam position intensity profile on the
More informationPhotonic-based multi-wavelength sensor for object identification
Edith Cowan University Research Online ECU Publications Pre. 2011 2010 Photonic-based multi-wavelength sensor for object identification Kavitha Venkataraayan Edith Cowan University Sreten Askraba Edith
More informationSabeeh Irfan Ahmad, Physlab, 23 July 2016
Horiba ihr550 Spectrometer QuickInstallation and Operation Guide Sabeeh Irfan Ahmad, Physlab, 23 July 2016 The Horiba ihr550 is an imaging spectrometer that can be used both as a spectrograph and as a
More informationDiode laser modules based on new developments in tapered and broad area diode laser bars
Diode laser modules based on new developments in tapered and broad area diode laser bars Bernd Köhler *a, Sandra Ahlert a, Thomas Brand a, Matthias Haag a, Heiko Kissel a, Gabriele Seibold a, Michael Stoiber
More informationSpectro p photomete p r V-700 series
Spectrophotometer p V-700 series V-700 Series UV-Vis/NIR Spectrophotometers V-730 SBW=1.0 nm Class-leading high S/N V-730BIO New irm & Spectra Manager V-750/760/770 Wavelength-independent dynamic range
More informationJ-KAREN-P Session 1, 10:00 10:
J-KAREN-P 2018 Session 1, 10:00 10:25 2018 5 8 Outline Introduction Capabilities of J-KAREN-P facility Optical architecture Status and implementation of J-KAREN-P facility Amplification performance Recompression
More informationCAMAG TLC VISUALIZER 2
CAMAG TLC VISUALIZER 2 Professional Imaging and Documentation System for TLC/HPTLC Chromatograms with a new Digital CCD Camera, connected by USB 3.0 WORLD LEADER IN PLANAR CHROMATOGRAPHY Visualization,
More informationF/48 Slit Spectroscopy
1997 HST Calibration Workshop Space Telescope Science Institute, 1997 S. Casertano, et al., eds. F/48 Slit Spectroscopy R. Jedrzejewski & M. Voit Space Telescope Science Institute, Baltimore, MD 21218
More informationRAMSES. A modular multispectral radiometer for light measurements in the UV and VIS
RAMSES A modular multispectral radiometer for light measurements in the UV and VIS Rüdiger Heuermann a, Rainer Reuter b and Rainer Willkomm a a TriOS Mess- und Datentechnik GmbH, Oldenburg, Germany b Fachbereich
More informationOptics for EUV Lithography
Optics for EUV Lithography Dr. Sascha Migura, Carl Zeiss SMT GmbH, Oberkochen, Germany 2018 EUVL Workshop June 13 th, 2018 Berkeley, CA, USA The resolution of the optical system determines the minimum
More informationChemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES
Chemistry 524--"Hour Exam"--Keiderling Mar. 19, 2013 -- 2-4 pm -- 170 SES Please answer all questions in the answer book provided. Calculators, rulers, pens and pencils permitted. No open books allowed.
More informationOriel MS260i TM 1/4 m Imaging Spectrograph
Oriel MS260i TM 1/4 m Imaging Spectrograph MS260i Spectrograph with 3 Track Fiber on input and InstaSpec CCD on output. The MS260i 1 4 m Imaging Spectrographs are economical, fully automated, multi-grating
More informationCr, Co, Cu, Mo, Ag (others on request) Mean Reflectivity: R > 70%
PARALLEL BEAM X-RAY OPTICS y Mirror length L Θ = f(x) b p/2 λ = 2d eff (x) sin Θ(x) eff x m Parallel beam width b=f(p,λ,l,,l,x m ) x Fabrication of high precision 6 mm parallel beam optics both on prefigured
More informationExamination Optoelectronic Communication Technology. April 11, Name: Student ID number: OCT1 1: OCT 2: OCT 3: OCT 4: Total: Grade:
Examination Optoelectronic Communication Technology April, 26 Name: Student ID number: OCT : OCT 2: OCT 3: OCT 4: Total: Grade: Declaration of Consent I hereby agree to have my exam results published on
More informationCHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES
CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES The current multiplication mechanism offered by dynodes makes photomultiplier tubes ideal for low-light-level measurement. As explained earlier, there
More informationUV-VIS-IR Spectral Responsivity Measurement System for Solar Cells
November 1998 NREL/CP-52-25654 UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells H. Field Presented at the National Center for Photovoltaics Program Review Meeting, September 8 11, 1998,
More information