PyroBus Non-Contact Temperature Sensor with RS485 Modbus Interface

Size: px
Start display at page:

Download "PyroBus Non-Contact Temperature Sensor with RS485 Modbus Interface"

Transcription

1 PyroBus NonContact Temperature Sensor with RS485 Modbus Interface An innovative range of compact infrared pyrometers with builtin digital communications for easy systems integration

2 Wide temperature range from 2 C to 5 C Builtin RS485 Modbus RTU Interface Configurable emissivity setting and signal processing Max; min; average and instantaneous readings; peak or valley hold; reflected energy compensation 2:1, 15:, 3:1 or close focus optics Fast response with high stability Stainless steel housing, sealed to IP65 Quick and easy installation Optional air/water cooled housing, air purge collar, laser sighting tool and mounting brackets Optional PM24 TouchScreen Terminal for configuring and displaying data from up to eight PyroBus sensors The PyroBus Series is a range of high quality, low cost, compact sensors which measure the temperature of inaccessible or moving objects and materials. They measure temperatures from 2 C to 5 C, accurately and consistently, with an outstanding response time of 24 ms. Twoway digital communications via a builtin RS485 Modbus RTU interface enables the user to adjust the emissivity setting; compensate for reflected energy; apply filtering; select maximum, minimum, average or instantaneous readings; and peak or valley hold processing. Up to thirty two sensors can be installed on a single multidrop network. All PyroBus sensors are fitted with precision Germanium lenses for accurate optics. Model PB21 has 2:1 optics making it suitable for most applications where the sensor can be mounted close to the target. Model PB151 is designed for small or distant targets and has an optical resolution of 15:1. Model PB31 is designed for very small or distant targets and has an optical resolution of 3:1. Model PBCF is designed for targets as small as ø5mm at a distance of 1mm from the sensor. These compact sensors are small enough to fit almost anywhere and their rugged stainless steel housings make them ideal for applications where cleanliness and hygiene are paramount. General Specifications Temperature Range 2 C to 5 C Interface RS485 Modbus RTU Accuracy ±1% of reading or ±1ºC whichever is greater Repeatability ± % of reading or ± ºC whichever is greater Emissivity.2 to 1. Response Time, t 9 24 ms (9% response) Spectral Range 8 to 14 μm Supply Voltage 12 V DC nominal (6 13 V DC) Supply Current 5 ma max. Baud Rate 96 baud * Format 8 data bits, no parity, 1 stop bit * Mechanical Construction stainless Steel Dimensions 18 mm diameter x 13 mm long Thread Mounting M16 x 1 mm pitch Cable Length 1m (longer lengths available to order) Weight with Cable 95 g ENVIRONMENTAL Environmental Rating IP65 Ambient Temperature ºC to 7ºC Relative Humidity 95% max. noncondensing * Other configurations available upon request DIAMETER OF TARGET SPOT MEASURED VERSUS DISTANCE FROM SENSING HEAD Distance: Sensor to object Distance: Sensor to object D:S 2:1 D:S 15: Distance: Sensor to object Distance: Sensor to object PB21 PB151 Distance: Sensor to object Distance: Sensor to object 5 1 PB31 D:S 3:1 Distance: Sensor to object Distance: Sensor to object PBCF

3 The PM24 is a 32x24 pixel touchscreen terminal with a 3.5 colour TFT display. It allows the user to display data from up to eight PyroBus sensors and configure each sensor individually. The configuration parameters include emissivity setting, signal averaging, peak or valley hold processing and reflected energy compensation. There are two versions available. Each one provides all of the features above, however, the enhanced PM24E also provides analogue transmission for up to four sensors, plus two adjustable alarm outputs per sensor for all eight sensors. PM24 SPECIFICATIONS Display LCD type TFT 32 x 24, 3.5 touch screen Resistive PM24E PM24 Panel cutout 132 x 89 mm /1 mm 26 mm Supply Voltage 12 to 24 V DC Power Consumption 8 W Ambient Temperature Range C to 45 C Relative Humidity 35% to 95%, noncondensing Environmental Rating IP54 (front), IP3 (housing) Dimensions 14mm wide x 1mm tall x 44mm deep (PM24) 14mm wide x 1mm tall x 65mm deep (PM24E) Outputs (PM24E only) 4 analogue outputs, to 1 V DC, 16 programmable alarm outputs,12/24 V DC, 7 ma, (3 A max. per block of 8 outputs). HARDWARE AND SOFTWARE DATA Serial port EXP1 RS485 Modbus RTU interface for PyroBus sensors Serial port COM2 RS485 / RS232 interface for second display (read only) PyroBus with Modbus Master PyroBus Sensor #1 12 VDC PyroBus with PM24 PyroBus Sensor #1 12 VDC Analogue transmission & alarm outputs (PM24E only) PyroBus Sensor #32 RS485 RS RS PWR PWR Modbus Master PyroBus Sensor #8 RS RS PWR PWR RS485 EXP1 RS485 COM2 PM24 Sensor Configuration & Display RS485 EXP1 Optional PM24 or other Modbus Master (Display only)

4 All PyroBus Series Sensors are supplied with a stainless steel mounting nut and are easy to install. Standard sensors will operate in ambient temperatures up to 7 C. For more hostile environments or difficult mounting conditions a wide range of accessories is available. Accessories Fixed mounting bracket The Lshaped fixed mounting bracket offers a rigid support for the sensor and allows fine adjustment in a single plane. Adjustable mounting bracket The adjustable mounting bracket consists of a fixed mounting bracket plus another Lshaped bracket. When assembled as shown the adjustable mounting bracket offers a rigid support for the sensor and allows fine adjustment in two planes. Air purge collar The air purge collar is used to keep dust, fumes, moisture and other contaminants away from the lens. Air flows into the fitting on the side and out of the aperture at the front. Air/water cooled housing The air/water cooled housing allows the sensor to withstand ambient temperatures which exceed the normal 7 C limit. Air or water (depending on the degree of cooling required) flows into one of the fittings on the side and out of the other. To prevent condensation forming on the lens, the air/water cooled housing is supplied complete with an air purge collar. Please note, the air/water cooled housing must be ordered with the sensor and cannot be fitted by the user. Laser Sighting Tool The Laser Sighting Tool screws onto the front of the sensor during installation and indicates precisely where the sensor is aiming. Once the sensor has been aimed at the centre of the target and locked in position the Laser Sighting Tool can be removed. The laser is activated by means of a push button on the front of the tool which has a latching mechanism. Issue C July 1 Specifications subject to change without notice Calex Electronics Limited PO Box 2, Leighton Buzzard, Bedfordshire, England LU7 4AZ Tel: 44 () /8538 Fax: 44 () Locall Tel: info@calex.co.uk Online:

5 PyroCouple M TwoPiece NonContact Temperature Sensor The PyroCouple M Series is a range of miniature infrared temperature sensors with separate electronics. PyroCouple M sensors are capable of measuring temperatures in the range 2 C to 5 C and are available with either a current, voltage or thermocouple output. Issue C July 1 Specifications subject to change without notice General Specifications Temperature Range (other sub ranges to order) Field of View 2ºC to 1ºC ºC to 25ºC ºC to 5ºC DIAMETER OF TARGET SPOT MEASURED VERSUS DISTANCE FROM SENSING HEAD 2:1 PCM21LTX PCM21MTX 15:1 PCM151LTX PCM151MTX PCM151HTX 3:1 PCM31LTX PCM31MTX PCM31HTX ø 1mm PCMCFLTX PCMCFMTX PCMCFHTX Output See table Accuracy ±1% of reading or ±1 C whichever is greater Repeatability ±% of reading or ± C whichever is greater Emissivity Fixed at.95 Response Time, t9 24 ms (9% response) Spectral Range 8 to 14 µm Power 24 V DC (13 V DC to 28 V DC max) Max. Loop Impedance 75 Ω (42 ma output) Output Impedance 56 Ω (voltage/thermocouple output) MECHANICAL Sensing head Electronics Module Construction Stainless Steel Diecast Aluminium Dimensions 18 mm dia. x 45 mm long 98mm x 64mm x 34mm Thread Mounting M16 x 1 mm pitch Cable Length Weight with Cable ENVIRONMENTAL Distance: Sensor to object Distance: Sensor to object D:S 2:1 D:S 15: Distance: Sensor to object PCM21 Distance: Sensor to object PCM151 1 m 25 g Environmental Rating IP65 Ambient Temperature Range C to 7 C Relative Humidity 95% max. noncondensing 3.1 Distance: Sensor to object D:S 3:1 Distance: Sensor to object 5 1 PCM31 Calex Electronics Limited PO Box 2, Leighton Buzzard, Bedfordshire, England LU7 4AZ Tel: 44 () /8538 Fax: 44 () Locall Tel: info@calex.co.uk Online: Distance: Sensor to object Distance: Sensor to object PCMCF Output ModelX 42 ma 5 mv 1 T thermocouple 2 J thermocouple 3 K thermocouple 4 5V 5 The miniature sensing head measures just 18mm diameter x 45mm. It is made of stainless steel, sealed to IP65, and will operate in ambient temperatures up to 7 C without additional cooling. This makes the PyroCouple M Series ideal for applications where there is only a small amount of room available to mount the sensor or the ambient temperature around the sensing head is higher than normal. The electronics module measures 98mm x 64mm x 34mm. It is made of diecast aluminium, sealed to IP65, and will operate in ambient temperatures up to 7 C. It is powered from a 24 VDC (28 VDC max) power source. The emissivity setting is fixed at.95, making the PyroCouple M Series suitable for the majority of applications where the target is made of a nonreflective material such as paper, plastic, rubber, cloth, food etc. or it can be used to measure metals that are painted, anodised or oxidised. Accessories Fixed mounting bracket Adjustable mounting bracket Air purge collar Laser sighting tool Options Other outputs available upon request Longer cable (3 m max.) Certificate of calibration

6 PyroEpsilon Compact NonContact Temperature Sensor with Controllable Emissivity Setting Temperature range: 2 C to 5 C Twowire 42 ma output proportional to target temperature 42mA input to control emissivity setting Optional PyroTune manual emissivity adjuster Field of view: 2:1, 15:1, 3:1 or close focus Fast response with high stability Stainless steel housing, sealed to IP65 Quick and easy installation PyroEpsilon sensor with optional PyroTune emissivity adjuster Optional air/water cooled housing, air purge collar, laser sighting tool and mounting brackets The PyroEpsilon Series is a range of high quality, low cost, compact sensors which measure the temperature of inaccessible or moving objects and materials. They measure temperatures from 2 C to PyroEpsilon Sensor Display/Controller PWR PWR 42mA 42mA = Target Temperature PyroTune or PLC 5 C, accurately and consistently, with an outstanding response time of 24 ms. PyroEpsilon sensors transmit the target temperature as a 42 ma output and offer a simple solution for most noncontact temperature measurement applications. The sensor s emissivity setting can be IP IP 42mA SC V 24V 42mA = Emissivity Setting adjusted from.2 to 1. to cope with different target materials and is controlled by a 42 ma input. This gives the opportunity to adjust the emissivity setting automatically from a programmable logic controller (PLC). Alternatively the emissivity setting can be adjusted manually using the optional PyroTune module. If the 42 ma input is left open or shortcircuit the emissivity setting defaults to.95.

7 DIAMETER OF TARGET SPOT MEASURED VERSUS DISTANCE FROM SENSING HEAD Distance: Sensor to object Distance: Sensor to object D:S 2:1 D:S 15: Distance: Sensor to object Distance: Sensor to object PE21 Pyroepsilon Specifications Temperature Range vs FieldofView table Field of View 2ºC to 1ºC ºC to 25ºC ºC to 5ºC 2:1 PE21LT PE21MT 15:1 PE151LT PE151MT PE151HT 3:1 PE31LT PE31MT PE31HT 1mm PECFLT PECFMT PECFHT Output Accuracy Repeatability Emissivity Response Time, t 9 Spectral Range Supply Voltage Min. Sensor Voltage Max. Loop Impedance Input Impedance Mechanical Construction Dimensions Thread Mounting Cable Length Weight with Cable 42mA ±1% of reading or ±1ºC whichever is greater ± % of reading or ± ºC whichever is greater.2 to 1. via 42mA input 24 ms (9% response) 8 to 14 μm 24 V DC (28 V DC max.) 6 V DC 9 Ω ( 42 ma output) 5 Ω Stainless Steel 18 mm diameter x 13 mm long M16 x 1 mm pitch 1m (longer lengths available to order) 95 g ENVIRONMENTAL Environmental Rating IP65 Ambient Temperature Range ºC to 7ºC Relative Humidity 95% max. noncondensing PyroTUNE Specifications Output Supply Voltage Display Format Display Units Adjustment Mechanical Construction Mounting Dimensions Weight PE151 42mA 24 V DC (13 V to 28 V DC) 3.5 digit LCD Emissivity (.2 to 1.) or current (4 2 ma) Pushbuttons (raise/lower/set) Polycarbonate with gasket, transparent lid (PC) and quick release screws Surface 65 mm tall x 5 mm wide x 35 mm deep 72 g ENVIRONMENTAL Environmental Rating IP65 Ambient Temperature Range ºC to 7ºC Relative Humidity 95% max. noncondensing Calex Electronics Limited PO Box 2, Leighton Buzzard, Bedfordshire, England LU7 4AZ Tel: 44 () /8538 Fax: 44 () Locall Tel: info@calex.co.uk Online: Distance: Sensor to object Distance: Sensor to object 5 1 PE31 D:S 3:1 Distance: Sensor to object Distance: Sensor to object PECF All PyroEpsilon sensors are fitted with precision Germanium lenses for accurate optics. Model PE21 has 2:1 optics making it suitable for most applications where the sensor can be mounted close to the target. Model PE151 is designed for small or distant targets and has an optical resolution of 15:1. Model PE31 is designed for very small or distant targets and has an optical resolution of 3:1. Model PECF is designed for targets as small as ø5 mm at a distance of 1 mm from the sensor Accessories Fixed mounting bracket The Lshaped fixed mounting bracket offers a rigid support for the sensor and allows fine adjustment in a single plane. Adjustable mounting bracket The adjustable mounting bracket consists of a fixed mounting bracket plus another Lshaped bracket. When assembled as shown the adjustable mounting bracket offers a rigid support for the sensor and allows fine adjustment in two planes. Air purge collar The air purge collar is used to keep dust, fumes, moisture and other contaminants away from the lens. Air flows into the fitting on the side and out of the aperture at the front. Air/water cooled housing The air/water cooled housing allows the sensor to withstand ambient temperatures which exceed the normal 7 C limit. Air or water (depending on the degree of cooling required) flows into one of the fittings on the side and out of the other. To prevent condensation forming on the lens, the air/water cooled housing is supplied complete with an air purge collar. Please note, the air/water cooled housing must be ordered with the sensor and cannot be fitted by the user. Laser Sighting Tool The Laser Sighting Tool screws onto the front of the sensor during installation and indicates precisely where the sensor is aiming. Once the sensor has been aimed at the centre of the target and locked in position the Laser Sighting Tool can be removed. The laser is activated by means of a push button on the front of the tool which has a latching mechanism. Issue C July 1 Specifications subject to change without notice

8 PyroUSB 2.2 PC Configurable Infrared Temperature Sensor for Demanding Applications Shortwavelength measurement for lowemissivity targets such as steel rollers and other metal surfaces, even at low temperatures Configurable temperature range, emissivity setting etc. from a PC via CalexSoft software and USB cable (supplied) Features max, min, average and instantaneous readings; peak or valley hold; reflected energy compensation OPC Server capabilities Temperature ranges from 45 C to 2 C Emissivity:.1 to 1. Stainless steel housing, sealed to IP65 Field of view: 15:1, 25:1, 75:1 or Close Focus Selectable to 2 ma or 4 to 2 ma output Optional air/water cooled housing, air purge collar, laser sighting tool and mounting brackets sensor connection N/C Red Blue Green Yellow Red Blue Green Yellow USB USB Display/ Controller Display/ Controller Note: The sensor must be grounded at only one point, either the cable shield or the sensor housing. PC PC The PyroUSB 2.2 Series of infrared pyrometers measures temperatures from 45 C to 2 C accurately and consistently, with an outstanding response time. The selectable to 2 ma or 4 to 2 ma output is compatible with almost any indicator, controller, recorder, data logger etc. without the need for special interfacing or signal conditioning. Models with temperature range 45 C to 3 C, or 1 C to 4 C have 15:1 optics. For models with temperature range 25 C to 1 C, or 45 C to 2 C, a choice of optics is available: PU models have 25:1 optics and are suitable for most target sizes and distances. PU models are specially designed for distant targets and have an optical resolution of 75:1. PUCF2.2 models are designed for small targets and measure a spot size of ø 7.5 mm at 5 mm distance. All PyroUSB 2.2 Series sensors are fully configurable from a PC using the CalexSoft software and USB cable supplied. This userfriendly software enables the user to set the temperature range and emissivity setting, compensate for reflected energy; apply filtering; select max, min, average or instantaneous readings; and configure peak or valley hold processing. These features can also be monitored and adjusted by an OPC Client. Other features include data acquisition, alarms and a scrolling graphical display. The sensor will operate with either the 4 to 2 ma cable connected, the USB cable connected, or both. The USB cable has an IP65 connector at the sensor end. An IP65 cap protects the sensor when the USB cable is not connected.

9 DIAMETER OF TARGET SPOT MEASURED VERSUS DISTANCE FROM SENSING HEAD (9% energy) Distance: Sensor to object D:S 15: Distance: Sensor to object PyroUSB Distance: Sensor to object D:S 25: Distance: Sensor to object PyroUSB Accessories Fixed and adjustable mounting brackets Air purge collar The air purge collar is used to keep dust, fumes, moisture and other contaminants away from the lens. Distance: Sensor to object Distance: Sensor to object Mechanical Construction Dimensions Thread mounting Weight with Output Cable Output Cable Length USB Cable Length ENVIRONMENTAL Environmental Rating Ambient Temperature Relative Humidity D:S 75:1 PyroUSB General Specifications 2.2 Distance: Sensor to object Distance: Sensor to object PyroUSB 2.2CF Temperature Range LT: 45 C* to 3 C (PU151LT2.2 only) PT: 1 C to 4 C (PU151PT2.2 only) MT: 25 C to 1 C HT: 45 C to 2 C FieldofView 15:1 (PU151LT or PT) 25:1 (PU251MT or HT) 75:1 (PU751MT or HT) 5mm (PUCFMT or HT) Output Selectable 4 to 2 ma or to 2 ma (linear with temperature) Configuration Via PC port conforming to USB 2. Accuracy * ±1% of reading or ±2 C, whichever is greater Repeatability * ±% of reading or ± C, whichever is greater Emissivity Setting.1 to 1. Response Time, t 9 24 ms (9% response) Spectral Range 2. to 2.4 μm Supply Voltage 24 V DC (26 V DC max) Sensor Voltage 11 V DC min Max Loop Impedance 9 24 V DC Maximum Span Full temperature range (up to 155 C) Minimum Span 1 C * Object temperature > T min (see graph of Minimum Measurable Temperature) Stainless Steel 25 mm diameter x 16.5 mm long M2 x 1 mm pitch 175 g 1 m (longer cable available to order) 1 m IP65 C to 7 C 95% max. noncondensing Calex Electronics Limited PO Box 2, Leighton Buzzard, Bedfordshire, England LU7 4AZ Tel: 44 () /8538 Fax: 44 () Locall Tel: info@calex.co.uk Online: Air/water cooled housing The air/water cooled housing allows the sensor to withstand ambient temperatures which exceed the normal 7 C limit. Air or water (depending on the degree of cooling required) flows into one of the fittings on the side and out of the other. To prevent condensation forming on the lens, the air/ water cooled housing is supplied complete with an air purge collar. Please note, the air/water cooled housing must be ordered with the sensor and cannot be fitted by the user. Laser Sighting Tool The Laser Sighting Tool screws onto the front of the sensor during installation and indicates precisely where the sensor is aiming. Once the sensor has been aimed at the centre of the target and locked in position the Laser Sighting Tool can be removed. The laser is activated by means of a push button on the front of the tool which has a latching mechanism. Minimum Measurable Temperature (PU151LT2.2 only) Graph showing the minimum measurable object temperature (T min ), determined by surface emissivity (ε) and sensor temperature (T S ). Model Numbers PUxxx xx 2.2 xx Cooling (blank) = Uncooled sensor WJ = Air/water cooled jacket with air purge collar Temperature range LT = 45 to 3 C (model PU151LT2.2 only) PT = 1 to 4 C (model PU151PT2.2 only) MT = 25 to 1 C HT = 45 to 2 C Field of view 151 = 15:1 divergent optics (model PU151LT or PT) 251 = 25:1 divergent optics (model PU251MT or HT) 751 = 75:1 divergent optics (model PU751MT or HT) CF = Closefocus optics (focal spot size 7.5 mm at 5 mm distance) (model PUCFMT or HT) Issue H Oct 11 Specifications subject to change without notice

10 PyroUSB PC Configurable NonContact Temperature Sensor with 4 to 2 ma Output shown actual size The PyroUSB Series is a range of high performance, compact sensors which measure the temperature of inaccessible or moving objects and materials.

11 Configurable temperature range, emissivity setting etc. from a PC via CalexSoft software and USB cable (supplied) Features max; min; average and instantaneous readings; peak or valley hold; reflected energy compensation OPC Server capabilities Temperature range 4 to 1 C Emissivity:.1 to 1. Response time: 24 ms to 9% Stainless steel housing, sealed to IP65 Field of view: 15:1, 3:1 or Close Focus 4 to 2 ma output Quick and easy installation Optional air/water cooled housing, air purge collar, laser sighting tool and mounting brackets GENERAl SPECIFICATIONS Temperature Range 4 C to 1 C FieldofView 15:1 (PyroUSB151) 3:1 (PyroUSB31) 1mm (PyroUSBCF) Output 4 to 2 ma (linear with temperature) Configuration Via PC port conforming to USB 2. Accuracy Repeatability ±1% of reading or ±1 C whichever is greater ±% of reading or ± C whichever is greater Emissivity.1 to 1. Response Time, t 9 24 ms (9% response) Spectral Range 8 to 14 µm Supply Voltage Sensor Voltage Maximum Loop Impedance 24 V DC (28Vdc max) 6 V DC min 9 Ω Maximum Span 1 C Minimum Span 1 C MEChANICAl Construction Dimensions Thread mounting Weight with Output Cable Output Cable Length USB Cable Length Stainless Steel 25 mm diameter x 16.5 mm long M2 x 1 mm pitch 175 g 1 m 1 m ENVIRONMENTAl Environmental Rating IP65 Ambient Temperature Range C to 7 C Relative Humidity 95% max. noncondensing

12 The PyroUSB Series measures temperatures from 4 C to 1 C accurately and consistently, with an outstanding response time of 24 ms. The 4 to 2 ma output is compatible with almost any indicator, controller, recorder, data logger etc. without the need for special interfacing or signal conditioning. PyroUSB151 has 15:1 optics making it suitable for most applications. PyroUSB 31 is specially designed for distant targets and has an optical resolution of 3:1. PyroUSBCF is designed for small targets and measures a spot size of ø5mm at 1mm distance. All PyroUSB Series sensors are fully configurable from a PC using the CalexSoft software and USB cable supplied. This user friendly software enables the user to set the range and emissivity, compensate for reflected energy; apply filtering; select max, min, average or instantaneous readings; and peak or valley hold processing. These features can also be monitored and adjusted by an OPC Client. Other features include Data Acquisition, Alarms and a Scrolling Graphical Display. The sensor will operate with either the 4 to 2 ma cable connected, the USB cable connected, or both. The USB cable has an IP65 connector at the sensor end. An IP65 cap protects the sensor when the USB cable is not connected. DIAMETER OF TARGET SPOT MEASURED VERSUS DISTANCE FROM SENSING head Distance: Sensor to object D:S 15:1 Distance: Sensor to object D:S 3:1 Distance: Sensor to object Distance: Sensor to object Distance: Sensor to object Distance: Sensor to object PyroUSB151 PyroUSB31 PyroUSBCF

13 All PyroUSB Series Sensors are supplied with a stainless steel mounting nut and are easy to install. Standard sensors will operate in ambient temperatures up to 7 C. For more hostile environments or difficult mounting conditions a wide range of accessories is available. ACCESSORIES FIXED MOUNTING BRACKET The lshaped fixed mounting bracket offers a rigid support for the sensor and allows fine adjustment in a single plane. ADJUSTABlE MOUNTING BRACKET The adjustable mounting bracket consists of a fixed mounting bracket plus another lshaped bracket. When assembled as shown the adjustable mounting bracket offers a rigid support for the sensor and allows fine adjustment in two planes. AIR PURGE COllAR The air purge collar is used to keep dust, fumes, moisture and other contaminants away from the lens. Air flows into the fitting on the side and out of the aperture at the front. AIR/WATER COOlED housing The air/water cooled housing allows the sensor to withstand ambient temperatures which exceed the normal 7 C limit. Air or water (depending on the degree of cooling required) flows into one of the fittings on the side and out of the other. To prevent condensation forming on the lens, the air/water cooled housing is supplied complete with an air purge collar. Please note, the air/water cooled housing must be ordered with the sensor and cannot be fitted by the user. laser SIGhTING TOOl The laser Sighting Tool screws onto the front of the sensor during installation and indicates precisely where the sensor is aiming. Once the sensor has been aimed at the centre of the target and locked in position the laser Sighting Tool can be removed. The laser is activated by means of a push button on the front of the tool which has a latching mechanism. OPTIONS longer output cable (3 m max.) Certificate of calibration Issue B Dec 9 Specifications subject to change without notice Calex Electronics Limited PO Box 2, leighton Buzzard, Bedfordshire, England lu7 4AZ Tel: 44 () /8538 Fax: 44 () locall Tel: info@calex.co.uk Online:

14 PyroCouple Compact NonContact Temperature Sensor with optional Dual Output Temperature range: 2 C to 5 C Emissivity setting: fixed at.95 Twowire 42 ma output or fourwire voltage/thermocouple output Fourwire unit also provides internal sensor temperature Field of view: 2:1, 15:1, 3:1 or close focus Fast response with high stability Stainless steel housing, sealed to IP65 Quick and easy installation Optional air/water cooled housing, air shown actual size purge collar, laser sighting tool and mounting brackets Twowire units (option ) PWR PWR 42mA Display/Controller 42mA = Target Temperature The PyroCouple Series is a range of high quality, low cost, compact sensors which measure the temperature of inaccessible or moving objects and materials. They measure temperatures from 2 C to 5 C, accurately and consistently, with an outstanding response time of 24 ms. PyroCouple sensors are available as either twowire or fourwire units. Fourwire units (options 1 to 4) Display/Controller PWR PWR OP OP 42mA 42mA = Sensor Temperature Display/Controller mv/tc = Target Temperature Twowire PyroCouple sensors transmit the target temperature as a 42 ma output and offer a simple solution for most noncontact temperature measurement applications. Fourwire PyroCouple sensors transmit the target temperature as a 5 mv or thermocouple output (type J, K or T) plus the internal sensor temperature as a 42 ma output. This second output can be used to ensure that the sensor is being operated within the correct ambient temperature limits and prevent damage caused by overheating or overcooling. It can also be used to give an approximate indication of the air temperature surrounding the sensor.

15 DIAMETER OF TARGET SPOT MEASURED VERSUS DISTANCE FROM SENSING HEAD Distance: Sensor to object Distance: Sensor to object D:S 2:1 D:S 15: Distance: Sensor to object Distance: Sensor to object PC21 General Specifications Temperature Range vs FieldofView table Field of View 2ºC to 1ºC ºC to 25ºC ºC to 5ºC 2:1 PC21LTX PC21MTX 15:1 PC151LTX PC151MTX PC151HTX 3:1 PC31LTX PC31MTX PC31HTX 1mm PCCFLTX PCCFMTX PCCFHTX Output table ModelX Target Temperature Output Sensor Temperature Output 42 ma Not available 1 5 mv 42 ma 2 Type T thermocouple 42 ma 3 Type J thermocouple 42 ma 4 Type K thermocouple 42 ma e.g. Model PC151HT4 has a 15:1 field of view and provides a type K thermocouple output representing target temperatures of ºC to 5ºC plus a 42 ma output proportional to internal sensor temperature. For simplicity, the sensor temperature range is always set the same as the target temperature range Accuracy ±1% of reading or ±1ºC whichever is greater Repeatability ± % of reading or ± ºC whichever is greater Emissivity Fixed at.95 Response Time, t 9 24 ms (9% response) Spectral Range 8 to 14 μm Supply Voltage 24 V DC (28 V DC max.) Min. Sensor Voltage 6 V DC Max. Loop Impedance 9 Ω ( 42 ma output) Output Impedance 56 Ω (voltage/thermocouple output) Mechanical Construction Dimensions Thread Mounting Cable Length Weight with Cable PC151 Stainless Steel 18 mm diameter x 13 mm long m16 x 1 mm pitch 1m (longer lengths available to order) 95 g ENVIRONMENTAL Environmental Rating IP65 Ambient Temperature Range ºC to 7ºC Relative Humidity 95% max. noncondensing Calex Electronics Limited PO Box 2, Leighton Buzzard, Bedfordshire, England LU7 4AZ Tel: 44 () /8538 Fax: 44 () Locall Tel: info@calex.co.uk Online: Distance: Sensor to object Distance: Sensor to object 5 1 PC31 D:S 3:1 Distance: Sensor to object Distance: Sensor to object PCCF All PyroCouple sensors are fitted with precision Germanium lenses for accurate optics. Model PC21 has 2:1 optics making it suitable for most applications where the sensor can be mounted close to the target. Model PC151 is designed for small or distant targets and has an optical resolution of 15:1. Model PC31 is designed for very small or distant targets and has an optical resolution of 3:1. Model PCCF is designed for targets as small as ø5mm at a distance of 1mm from the sensor. Accessories Fixed mounting bracket The Lshaped fixed mounting bracket offers a rigid support for the sensor and allows fine adjustment in a single plane. Adjustable mounting bracket The adjustable mounting bracket consists of a fixed mounting bracket plus another Lshaped bracket. When assembled as shown the adjustable mounting bracket offers a rigid support for the sensor and allows fine adjustment in two planes. Air purge collar The air purge collar is used to keep dust, fumes, moisture and other contaminants away from the lens. Air flows into the fitting on the side and out of the aperture at the front. Air/water cooled housing The air/water cooled housing allows the sensor to withstand ambient temperatures which exceed the normal 7 C limit. Air or water (depending on the degree of cooling required) flows into one of the fittings on the side and out of the other. To prevent condensation forming on the lens, the air/water cooled housing is supplied complete with an air purge collar. Please note, the air/water cooled housing must be ordered with the sensor and cannot be fitted by the user. Laser Sighting Tool The Laser Sighting Tool screws onto the front of the sensor during installation and indicates precisely where the sensor is aiming. Once the sensor has been aimed at the centre of the target and locked in position the Laser Sighting Tool can be removed. The laser is activated by means of a push button on the front of the tool which has a latching mechanism. Issue C July 1 Specifications subject to change without notice

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets SILVER SERIES Low Cost, Single-Wavelength (1λ) Industrial Infrared Thermometers SSDS2013 Reliable compact industrial infrared thermometers for Temperatures below 3632 F/2000 C Non-reflective target materials

More information

PyroMiniUSB Series Operators Guide

PyroMiniUSB Series Operators Guide PyroMiniUSB Series Operators Guide The PyroMiniUSB is a simple, compact infrared temperature sensor with USB communications. It measures the surface temperature of a variety of materials without contact.

More information

User s Guide. OS301A-USB Series OS150A-2USB Series. Infrared Temperature Sensors. Shop online at omega.com

User s Guide. OS301A-USB Series OS150A-2USB Series. Infrared Temperature Sensors. Shop online at omega.com TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info OS301A-USB Series OS150A-2USB Series Infrared Temperature Sensors U.S.A. Headquarters: omega.com

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Metis H311 / H322. Highly Advanced, Full Featured 2-Color High-Speed Pyrometers

Metis H311 / H322. Highly Advanced, Full Featured 2-Color High-Speed Pyrometers Metis H311 / H322 Highly Advanced, Full Featured 2-Color High-Speed Pyrometers High-Speed 2-color pyrometer for non-contact temperature measurement in short wavelength spectral range, primarily for measurements

More information

Metis M311 / M322. Highly Advanced, Full Featured 2-Color Pyrometer Series

Metis M311 / M322. Highly Advanced, Full Featured 2-Color Pyrometer Series Metis M311 / M322 Highly Advanced, Full Featured 2-Color Pyrometer Series Self contained 2-color pyrometer for non-contact temperature measurement in short wavelength spectral range, primarily for measurements

More information

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional) Temperature Controller with Built-in SSR SB SB General Description SB is a channel temperature controller with Built-in SSR (Solid state relay) designed for flexible heating solutions such as heat trace

More information

Thermalert 4.0 Series

Thermalert 4.0 Series Thermalert 4.0 Series Smart Integrated Infrared Sensors Users Manual PN 4968276, English, Rev. 1.1, May 2018 2018 Fluke Process Instruments. All rights reserved. Printed in Germany. Specifications subject

More information

Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight Ratio, Data Logging, USB Output, Single Type K Input, and Temperature Alarm

Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight Ratio, Data Logging, USB Output, Single Type K Input, and Temperature Alarm User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight

More information

Metis M311 / M Color Pyrometer Series

Metis M311 / M Color Pyrometer Series Metis M311 / M322 2-Color Pyrometer Series Self contained 2-color pyrometer for non-contact temperature measurement in short wavelength spectral range, primarily for measurements on metals and bright and

More information

POWER CUBE SA/80 series

POWER CUBE SA/80 series POWER CUBE SA/80 series The 100, 50, 25 kw Green Generators Features / Benefits High Power output High level of performance with minimal operating costs Automatic tracking and best optimization to load

More information

4-20mA, 0-10V and general process measuring bargraph displays

4-20mA, 0-10V and general process measuring bargraph displays Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

Miniature resistance thermometer Model TR33, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted Electrical temperature measurement Miniature resistance thermometer Model TR33, thread-mounted WIKA data sheet TE 60.33 Applications Machine building, plant and vessel construction Propulsion technology,

More information

P5201 Universal Programmable Transmitters with Galvanic Isolation

P5201 Universal Programmable Transmitters with Galvanic Isolation Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to

More information

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information. / Length Micro Sensor LED-type Micro Sensor with Many Features in a Compact Body Compact body only /4th the volume of our previous product. % cost reduction over our previous product. High performance

More information

high accuracy tester-calibrator PJ 6301

high accuracy tester-calibrator PJ 6301 high accuracy testercalibrator PJ 6301 PJ6301 is a highaccuracy instrument: ± 0.005% with 600,000 measuring counts on voltage and current ranges; for thermocouple and for RTD measurement resolution. Simultaneous

More information

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS

More information

I-SERIES. Excellent Cost-Performance High-Accuracy Measurement. CMOS Analog Laser Sensor. Intelligent Sensor. IA Series

I-SERIES. Excellent Cost-Performance High-Accuracy Measurement. CMOS Analog Laser Sensor. Intelligent Sensor. IA Series NEW CMOS Analog Laser Sensor IA Series Excellent Cost-Performance High-Accuracy Measurement KEYENCE BRINGS YOU A GENERAL-PURPOSE ANALOG LASER SENSOR Intelligent Sensor I-SERIES NEW CMOS Analog Laser Sensor

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Rota-Sonde DC4500. Smart display with Signal level. Easy alignment with Laser Line. Design for the most difficult applications

Rota-Sonde DC4500. Smart display with Signal level. Easy alignment with Laser Line. Design for the most difficult applications Scanning HOT METAL DETECTOR Rota-Sonde DC4500 Smart display with Signal level Easy alignment with Laser Line Design for the most difficult applications Very High Sensitivity 360 F Lt 1445 1 Applications

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion

More information

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www. Model R2002 Infrared Thermometer Instruction Manual reedinstruments www com Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Operating Instructions...6-7 Battery

More information

SR Series Self-Contained Two-Color Infrared Thermometers

SR Series Self-Contained Two-Color Infrared Thermometers SR Series Self-Contained Two-Color Infrared Thermometers The SR series self-contained, two color infrared thermometers Introduction The SR Series infrared thermometer from Ircon is a two-color thermometer

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors. / Length (2D CMOS Laser Type) Advanced Functions Integrated into a Compact Sensor for Easy Handling of High-grade Applications A Controller the size of a business card combined with the smallest Sensor

More information

TEMPERATURE MEASUREMENT SPECIALISTS

TEMPERATURE MEASUREMENT SPECIALISTS TEMPERATURE MEASUREMENT SPECIALISTS 0845 053 3145 www.processparameters.co.uk Industrial Temperature Solutions After time, temperature is the most frequently measured parameter. It affects every aspect

More information

MARATHON MM SERIES. Operating Instructions. High-Performance Infrared Thermometer. Rev. C1 04/

MARATHON MM SERIES. Operating Instructions. High-Performance Infrared Thermometer. Rev. C1 04/ MARATHON MM SERIES High-Performance Infrared Thermometer Operating Instructions Rev. C1 04/2007 58201 Contacts Europe Raytek GmbH 13127 Berlin, Germany Blankenburger Str. 135 Tel: +49 30 478008 0 +49

More information

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A... Electronics & Software ICAM Type 5073A... Industrial Charge Amplifier for Applications in Manufacturing The ICAM charge amplifier (Industrial Charge Amplifier Manufacturing) converts the piezoelectric

More information

Improve asset protection and utilization

Improve asset protection and utilization QUALITROL 509 ITM Intelligent transformer monitor Improve asset protection and utilization Immediately know your transformer health with TransLife Optimize loading and equipment life Simplify root cause

More information

Moving Test - MT3000

Moving Test - MT3000 Moving Test - MT3000 Three-Phase Portable Test System Keep ahead with Modular Design The Modular Concept The MT3000 is based on a real modular design concept to provide the greatest possible flexibility

More information

Conductivity Analyzer

Conductivity Analyzer Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures

More information

+GF+ SIGNET Temperature Transmitter Instructions

+GF+ SIGNET Temperature Transmitter Instructions GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal

More information

MI Miniature Infrared Sensor

MI Miniature Infrared Sensor MI Miniature Infrared Sensor Operating Instructions Rev. F2 06/2006 54301 Declaration of Conformity for the European Community This instrument conforms to: EMC: IEC/EN 61326 1 Safety: EN 61010 1:1993 /

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

Pre-Calibrated Models

Pre-Calibrated Models C O R P O R A T I O N Pre-Calibrated Models Factory-calibrated to match thermocouple signals over selected temperature ranges For non-metal surfaces (coated metals are acceptable) For use with thermocouple

More information

DATA SHEET. OD Precision. Displacement sensors for precise and comprehensive measurement tasks

DATA SHEET. OD Precision. Displacement sensors for precise and comprehensive measurement tasks DATA SHEET OD Precision Displacement sensors for precise and comprehensive measurement tasks OD Precision Displacement sensors for precise and comprehensive measurement tasks Displacement sensors from

More information

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01% Transportable documenting multifunction calibrator with high accuracy 0.01% CALYS 1200 is the ideal solution to simultaneously simulate and measure with a high accuracy of 0.01%: voltage, current, resistance,

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

Relative Humidity & Temperature Transmitters

Relative Humidity & Temperature Transmitters Relative Humidity & Temperature Transmitters High Temperature Models up to 150 C (300 F) Series 740 and 741 EMC Immunity to EN 50082-1 Series 741: 2-Wire 4-20mA Ouput Series 740: User- Selectable Signals

More information

ACT AUTOMATIC CONTRAST TRACKING

ACT AUTOMATIC CONTRAST TRACKING The SMARTEYE EZ-PRO is a high performance, automatic photoelectric sensor that can be adjusted by a single push of a button. As a result, there is no guess work on the part of the operator. Now you can

More information

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM104 SERIES SEM104P Pt100 Temperature Transmitter SEM104TC Thermocouple Temperature Transmitter SEM104P 1 1.0 DESCRIPTION 2 2.0 SPECIFICATION 2 3.0 INSTALLATION 24 4.0

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External

More information

User Friendly Interface means: Power through Simplicity

User Friendly Interface means: Power through Simplicity W h a t i s t h e T & D T R - 5 i S e r User Friendly Interface means: Power through Simplicity The TR-5i Series is a family of data loggers designed to measure and record a variety of items: from temperature

More information

MARATHON MM SERIES. Operating Instructions. High-Performance Infrared Thermometer. Rev. D8 Sep

MARATHON MM SERIES. Operating Instructions. High-Performance Infrared Thermometer. Rev. D8 Sep MARATHON MM SERIES High-Performance Infrared Thermometer Operating Instructions Rev. D8 Sep 2017 58201 Contacts Fluke Process Instruments Americas Santa Cruz, CA USA Tel: +1 800 227 8074 (USA and Canada,

More information

THM80X Series Industry degree high accuracy Temp. & humidity transmitter

THM80X Series Industry degree high accuracy Temp. & humidity transmitter THM80X Series Industry degree high accuracy Temp. & humidity transmitter Introduction IP65 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General

More information

General Specifications

General Specifications General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

SILICon IrrADIAnCe SenSor

SILICon IrrADIAnCe SenSor Measurement of Solar Silicon irradiance sensors (Si sensor) show a cost-effective, but rugged and reliable solution for the measurement of solar irradiance, especially for the monitoring of Photovoltaic

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

INPROX sensors. displacement MLS compact ccd-laser distance sensor

INPROX sensors. displacement MLS compact ccd-laser distance sensor compact ccd- distance sensor MLS7-250 high vibration and shock resistant -CCD specifications measuring range 250mm resolution >50µm measuring frequency 1000Hz small dimensions (mm) (65x50x20) high shock

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

SRS SEALED ROTARY SENSORS

SRS SEALED ROTARY SENSORS SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

General Specifications

General Specifications General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent

More information

Industrial Modbus I/O Modules

Industrial Modbus I/O Modules Industrial Modbus I/O Modules Modbus I/O Modules Introduction & Features Digital Input / Output Modules Analog Input / Output Modules Modbus I/O Modules The Best Choice For Your SCADA Applications Introduction

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information. EN Manufactured by M-Sens 2 Online-Moisture Meter for Solids Product Information Moisture 13.47 % www.onthelevel.com Using M-Sens 2 is specifically designed for continuous moisture measurement of solids.

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology

High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology High-speed, High-Accuracy Digital Displacement Inductive Sensor EX-V Series High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology High-Performance

More information

USER S GUIDE. for MIDDLETON SOLAR SECONDARY STANDARD PYRANOMETER WITH INTEGRATING CAVITY DETECTOR

USER S GUIDE. for MIDDLETON SOLAR SECONDARY STANDARD PYRANOMETER WITH INTEGRATING CAVITY DETECTOR Part No. 111.1008 CE 2016 USER S GUIDE for MIDDLETON SOLAR ER08-S and ER08-SE SECONDARY STANDARD PYRANOMETER WITH INTEGRATING CAVITY DETECTOR Date: Dec. 2016 Version: 1.7 Middleton Solar, made in Australia.

More information

Paperless Recorder PR20

Paperless Recorder PR20 Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological

More information

Additel 875 Series Dry Well Calibrators

Additel 875 Series Dry Well Calibrators Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect

More information

General Specifications

General Specifications General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring

More information

MULTIFUNCTION GRAPHICAL UNIT MGU 800

MULTIFUNCTION GRAPHICAL UNIT MGU 800 MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible

More information

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0. R-Series Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH 25 7600 mm Perfect data processing 0.5 μm Rugged industrial sensor Linear and absolute measurement LEDs for sensor

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Portable Multi-Channel Recorder Model DAS240-BAT

Portable Multi-Channel Recorder Model DAS240-BAT Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes

More information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement Technical Data Sheet Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin

More information

OD Max and OD Max Transparent displacement sensors highly accurate, non-surface dependent distance measurement

OD Max and OD Max Transparent displacement sensors highly accurate, non-surface dependent distance measurement OD Max and OD Max Transparent displacement sensors highly accurate, non-surface dependent distance AUDIN - 8, avenue de la malle - 70 Saint Brice Courcelles - Tel : 0..0.0. - Fax : 0..0.8.0 - Web : http:

More information

Optical Data Couplers

Optical Data Couplers Optical Data Couplers DAD5-8P See pages 73-74 Features: Large operating angle and sensitivity adjustment allow for easy alignment LED display of input and output status Operating Ranges:.5 m, 2.5 m Data

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu PM8005/6 AC and DC supply options 5 digit LED display Direct access menu Functions for calibration, alarm setting and more Wide range of optional functions Description The PM8000 Series digital panel meters

More information

Resistance thermometer Model TR31, miniature design

Resistance thermometer Model TR31, miniature design Electrical temperature measurement Resistance thermometer Model TR31, miniature design WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

Model LS 250 Loop Scanner Operator s Manual. Version

Model LS 250 Loop Scanner Operator s Manual. Version Model LS 250 Loop Scanner Operator s Manual Version 05-2011 Contents 1. Introduction...2 2. Description...3 2.1 Model Nomenclature...3 2.2 Operating Principle...3 2.3 Specifications...5 3. Location and

More information

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11 USER'S GUIDE Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11 PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit

More information

Additel 875 Series Dry Well Calibrators

Additel 875 Series Dry Well Calibrators Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement Technical Data Sheet Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Wide Selection of High Performance Small DC Sensors Offers Longer Sensing Distances Fast 0. msec response time for high-speed sensing Extended sensing distances up

More information

Datasheet. Release date: 17 th of December, 2016 End users Validity date: 31 st of December, 2016 till next revision Revision Number: 1.

Datasheet. Release date: 17 th of December, 2016 End users Validity date: 31 st of December, 2016 till next revision Revision Number: 1. Datasheet Release date: 17 th of December, 2016 End users Validity date: 31 st of December, 2016 till next revision Revision Number: 1.1 Introduction Workswell s.r.o. is pleased to introduce you a brand

More information

MEMOCAL 2000/2000S. Hand-held calibrator

MEMOCAL 2000/2000S. Hand-held calibrator MEMOCAL 2000/2000S Hand-held calibrator MEMOCAL 2000 Very low temperature drift (0.1µV/ C) Accuracy: 0.015% of span Power supply: standard AA size battery (Alkaline, NiCd or Ni-MH) Measurement & generation

More information

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power

More information

Signet Flow Transmitter

Signet Flow Transmitter Signet 80- Flow *-80.090-* English -80.090- Rev. L 0/ English WARNING! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

Magnetic Linear Measuring System. MS01 Technical manual

Magnetic Linear Measuring System. MS01 Technical manual Magnetic Linear Measuring System MS1 Technical manual a The measuring scale is made of a polymerbonded ferritic material. An alternating magnetic field H is produced over the measuring carrier by systematic

More information

ES Series Features Detecting distance twice that of conventional

ES Series Features Detecting distance twice that of conventional Long-distance Separate-amplifier Series Features Detecting distance twice that of conventional sensors Detecting distance easily adjustable Wide range of sensor head types available Built-in alarm output

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

HD 48V01T... HD 4977T...

HD 48V01T... HD 4977T... RH-26 HD 4807T HD 4907T HD 48V07T HD 4901T... HD 4801T... HD 4917T... HD 48V01T... HD 4977T... HD 4817T... HD 48V17T... HD 4877T... HD 48V77T... HD 4807T, HD 48V07T, HD 48S07T, HD 4801T..., HD 48V01T...,

More information

Inductive Analog-Sensors

Inductive Analog-Sensors SENSOREN FÜR AUTOMATION Inductive Analog-Sensors Item group 260 Non-contacting measurement of distance and position -Distance -Displacement -Position -Edge guiding -Concentricity -Centering -Sorting -Counting

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

MLV40 Series Miniature Sensors

MLV40 Series Miniature Sensors MLV4 Series Miniature Sensors Diffuse Mode See page 54 Features: Adjustable sensitivity Complementary outputs Sensing Range: 5 mm Outputs: NPN, PNP Thru-Beam Mode See page 57 Rugged metal housing Compact

More information

High-precision process calibrator Model CED7000

High-precision process calibrator Model CED7000 Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry

More information