Comparison of Contrast Sensitivity in Eyes with Toric and Aspheric Intraocular Lenses

Size: px
Start display at page:

Download "Comparison of Contrast Sensitivity in Eyes with Toric and Aspheric Intraocular Lenses"

Transcription

1 ARTICLE Comparison of Contrast Sensitivity in Eyes with Toric and Aspheric Intraocular Lenses Francisco Pastor-Pascual, PhD 1 ; Aitor Lanzagorta-Aresti, MD 1 ; Pablo Alcocer-Yuste, MD 1 ; Cristina Puchades-Lladró 1 ; José Luis Menezo-Rozalén, PhD 1 INTRODUCTION: Study aimed to compare Visual Acuity, ocular Spherical Aberration (SA) and Contrast Sensitivity (CS) in eyes implanted with the AcrySof toric IOL and AcrySof Natural IQ. METHODS: Fifty-eight eyes of 46 patients participated in this prospective randomized study. After phacoemulsification the eyes received the AcrySof toric or AcrySof IQ IOLs depending on their preoperative corneal astigmatism. Three month after surgery, all patients underwent complete ophthalmological examination including corneal topography, best corrected visual acuity, wavefront analysis for 6 mm pupil diameter and CS measurements with the CSV-1000HGT test under photopic (85 cd/m 2 ) and mesopic conditions (5 cd/m 2 ). RESULTS: BCVA in toric group was 0.054±0.043 logmar and 0.030±0.037 logmar in aspheric group (all patients achieved a BCVA of 20/25 or better). The mean postoperative SA was higher in the AcrySof toric group than the AcrySof IQ group (0.540±0.887 vs ±0.047 µm) and this difference was statistically significant (p<0.001). CS results showed no statistically significant differences between the values post-implantation at any lighting condition and spatial frequency (p>0.01). The AcrySof toric lens provided excellent rotational stability in the capsular bag with an average lens rotation of less than 3.3±2.5 degrees. CONCLUSIONS: The AcrySof toric IOL and aspheric AcrySof IQ yield similar and good visual outcomes. However, the AcrySof IQ IOL reduced significantly the SA for large pupils in relation to toric IOL. Surgeons should consider that patients may benefit from aspheric designs. Future studies, should consider direct comparison between spherical and aspheric toric IOLs to analyze properly the benefit in visual performance. KEYWORDS: Visual acuity, Contrast Sensitivity and Spherical Aberration with AcrySof Natural IQ and Toric IOLs. J Emmetropia 2010; 1: Submitted: 5/23/2010 Revised: 6/7/2010 Accepted: 6/13/ Fundación Oftalmológica del Mediterráneo. Valencia. Spain. The authors have no proprietary interest in any of the materials mentioned in this article. The authors have no any financial support. Corresponding author: Francisco Pastor-Pascual. Fundación Oftalmológica del Mediterráneo. Bifurcación General Avilés-Pío Baroja s/n Valencia. Spain. Telephone: Fax: francisco_pastor@yahoo.es INTRODUCTION Approximately 15 20% of patients with cataracts have more than 1.5 diopters (D) of pre-existing astigmatism 1. Reducing this preoperative astigmatism can improve visual outcomes after cataract surgery. The astigmatism can be reduced with the phacoemulsification incisions, with corneal or limbal relaxing incisions and with excimer laser keratectomy. Another alternative for astigmatism correction in the cataract surgery is to implant a toric intraocular lens (IOL). Several reports have shown good outcomes in terms of safety, predictability, and efficacy after implantation of toric SECOIR Sociedad Española de Cirugía Ocular Implanto-Refractiva ISSN:

2 COMPARISON OF CONTRAST SENSITIVITY BETWEEN TORIC AND ASPHERIC IOLs 69 IOLs 2-8. Rotation of the toric IOL after implantation is the main problem associated with this modality The majority of this occurs within the first three months after implantation 12. Even a small rotational deviation of the toric IOL from its intended axis can result in large reduction of the astigmatic correction 13. For example, a deviation of 10 degrees minimizes potential correction by 35%. The optical quality of the eye is determined by the combination of corneal and lens aberrations. Combination of both surfaces is important to achieve the best optical quality of the whole eye 14. There are aspheric designs to produce negative spherical aberration (SA) in order to compensate the positive SA of the cornea. However low-order optical aberrations should be corrected efficiently also to provide the best optical quality, and thus visual quality, for cataract patients. The purpose of this study is to assess and compare the visual performance in patients implanted after cataract surgery with two IOLs, a spherical toric IOL, the AcrySof toric SN60Tx and an aspheric IOL, the AcrySof IQ SN60WF. PATIENTS AND METHODS Study Design Fifty-eight eyes of 46 patients who underwent cataract extraction by uncomplicated phacoemulsification and implantation of the AcrySof toric SN60Tx or AcrySof IQ SN60WF, depending on their preoperative corneal astigmatism, were included. If it was larger than 1.50 D, the IOL implanted was the AcrySof toric IOL. If it was smaller than 1.50 D the IOL was the AcrySof IQ IOL. The study was performed at the Fundación Oftalmológica del Mediterráneo, Valencia, Spain, between February 2008 and July Inclusion criteria included cataract, age between 45 and 85 years, and preoperative regular corneal astigmatism smaller than 5.00 D. Exclusion criteria included preoperative astigmatism larger than 5.00 D, history of glaucoma or retinal detachment, corneal disease, previous corneal or intraocular surgery, macular degeneration or retinopathy, and history of ocular inflammation. The AcrySof Natural IQ SN60WF (Alcon Laboratories Inc, Ft Worth, TX) is an aspheric IOL with negative SA (-0.20 µm with a 6.0 mm pupil) designed with prolate posterior surface to reduce the total amount of ocular SA when implanted after cataract or clear lens extraction. The AcrySof toric IOL SN60Tx (Alcon Laboratories Inc, Ft Worth, TX) is an open-loop, modified single piece, acrylic polymer IOL with L-shaped haptics. The IOL s toricity, located on the posterior surface, extends across the entire surface of the spherical optic. The IOL is available in 3 models: SN60T3, SN60T4, and SN60T5. The U.S. Food and Drug Administration (FDA) approved the AcrySof toric IOL in September 2005 for 3 cylindrical powers: 1.50 D, 2.25 D, and 3.00 D at the IOL plane (Available at: Accessed January 9, 2008). Before cataract surgery, patients had a complete ophthalmologic examination including manifest refractions, keratometry, topography (Pentacam system), slit lamp examination, applanation tonometry, and ocular fundus examination. Axial length and keratometry were measured with IOL Master (Carl Zeiss Meditec, Jena, Germany). The SRK/T formula was used for IOL power calculation. The targeted refraction was emmetropia. In the case of the Acrysof toric IOL was implanted the IOL model and axis placement was using a program available from the IOL manufacturer ( Preoperative keratometry and biometry, data, incision location, and the surgeon s estimated surgically induced corneal astigmatism were used to determine the appropriate AcrySof toric IOL model, spherical equivalent lens power and axis of placement in the eye. Surgical Technique Two experienced surgeons (A.L.,F.P.) performed all surgeries using peribulbar anesthesia. With the patient seated at the slitlamp and with a coaxial thin slit turned to the 0- to 180-degree axis, the corneal limbus was marked at the 0-degree and 180-degree positions with a sterile marker after vertical alignment of the patient s head. Next, with the patient lying on the surgical table, the steep corneal meridian was identified and marked using a Marquez gauge with the aid of the preplaced reference points. Phacoemulsification was performed through a 2.75 mm temporal corneal incision. In all cases, the target capsulorhexis diameter was 5.50 mm to ensure overlap of the IOL border. After phacoemulsification, a foldable AcrySof toric IOL was inserted in the capsular bag using the Monarch II injector (Alcon Laboratories Inc, Ft Worth, TX). The IOL was rotated to align the cylinder axis with the marked steep corneal meridian. There were no complications in any of the cases. The tenets of the Declaration of Helsinki were followed in this research. Informed consent was obtained from all patients after the nature and possible consequences of the study were explained. Institutional Review Board approval was obtained. Visual Performance Measurements Best spectacle-corrected visual acuity (BCVA) measurement was performed by means of the logarithm of the minimum angle of resolution (logmar) acuity

3 70 COMPARISON OF CONTRAST SENSITIVITY BETWEEN TORIC AND ASPHERIC IOLs charts under photopic conditions (85 cd/m 2 ). Ocular wavefront aberrations were measured with the LADARWave Hartmann-Shack aberrometer (Alcon Laboratories Inc, Ft Worth, TX) for 6 mm pupil. Monocular photopic and mesopic contrast sensitivity (CS) was measured with best distance correction using CSV-1000HGT (VectorVision, Dayton, Ohio) in both groups at 3 month after implantation. Absolute values of log 10 CS were obtained for each combination of patient, spatial frequency, and luminance; means and standard deviations were calculated. The CS measurements were taken under 2 illumination conditions: photopic at 85 cd/m 2 (luminance recommended in manufacturer s guidelines) and mesopic at 5 cd/m 2. IOL rotation was measured at the slitlamp in 1-degree steps using an eyepiece for angle measurement through pupils dilated with tropicamide. A thin coaxial slit was projected in front of the eye and rotated until the thin slit projection overlapped the axis marks of the IOL. Data Analysis All examinations were performed at 3 month after implantation by one ophthalmic technician who was unaware of the objective of the study. To explore any correlation between the BCVA, CS at 2 lighting conditions and SA measured between the two IOLs t-test was carried out. Differences were considered to be statistically significant when the p-value was <0.01 (i.e., at the 1% level). RESULTS The mean ages of the AcrySof toric and AcrySof IQ groups were 65.1±7.78 and 63.7±4.78 years, respectively. Mean IOL power was 18.97±4.30D in the AcrySof toric group and 21.61±2.28 D in the AcrySof IQ group. Patient demographics are shown in Table 1. No statistically significant differences were found between both groups in relation to age, IOL power, and pre- and post- sphere (p>0.01). We found statistically significant differences between both groups for pre- and post-cylinder (p=4.48x10-13 and p=1.77x10-3, respectively). After the surgery and IOL implantation, the pupils of all patients were round, without iris trauma, and showed a good responsiveness to light. Visual Acuity In the toric group the BCVA was 0.054±0.043 logmar and in the aspheric group was 0.030±0.037 logmar (in both groups, all the patients achieved a BCVA of 20/25 or better). No statistically significant differences were found between both groups for BCVA (p=0.015). Contrast Sensitivity The mean values of log 10 CS after implantation with the AcrySof toric and the Acrysof IQ IOLs were plotted as a series of CS Functions (CSF) in Figure 1. Left and right images shows distance CSFs at the different luminance levels (85 and 5 cd/m 2 ). To explore the statistical significance of differences between lenses, t-tests were performed on the comparable data of the two Figure 1. Contrast sensitivity functions after implantation of the AcrySof toric IOL SN60Tx and AcrySof Natural IQ SN60WF under photopic (85 cd/m 2 ) and mesopic conditions (5 cd/m 2 ). Table 1: Demographic Characteristics of Participants AcrySof Toric IOL (SN60Tx) AcrySof IQ IOL (SN60WF) P value Number of eyes Age (years) 65.1± ± Gender (Male/Female) 20/11 13/14 IOL Power (D) 18.97± ± Preoperative Sphere (D) -1.70± ± Preoperative Cylinder (D) -2.61± ± x10-13 Postoperative Sphere (D) 0.34± ± Postoperative Cylinder (D) -0.82± ± x10-3 IOL = intraocular lens; D = diopters; means ± standard deviation.

4 COMPARISON OF CONTRAST SENSITIVITY BETWEEN TORIC AND ASPHERIC IOLs 71 groups (absolute log 10 CS values) at each spatial frequency and illumination level. The results showed no statistically significant differences between the values post-implantation at any lighting condition and spatial frequency (p>0.01). Spherical Aberration The mean SA for each group before and after surgery is summarized in Table 2. The mean postoperative SA for a 6mm pupil was higher in the AcrySof toric group than the AcrySof IQ (0.540±0.887 versus 0.216±0.047 µm). This difference was statistically significant (p<0.001; Table 2). Rotational Stability The AcrySof toric lens provided good rotational stability in the capsular bag with an average lens rotation of less than 3.3±2.5 degrees, verifying the placement with photographies. DISCUSSION Previous clinical trials evaluated clinical, optical and functional outcomes after spherical and aspheric IOLs 21-31, however this is the first study that compares toric IOLs with aspheric IOLs. Toric IOLs are a predictable and stable alternative for correcting astigmatism in patients with cataracts and preexisting corneal astigmatism Success in achieving favourable postoperative visual function depends on several factors. First, patients with regular bowtie astigmatism may be benefit with toric IOL implantation. The second factor is to obtain accurate corneal astigmatism measurements to determine the actual amount of cylinder requiring correction and the spherical IOL power. The AcrySof toric IOL calculator program has been proved efficient for determining the toric IOL to be implanted and calculation of the implantation axis 3,16, The stability of the toric IOL is highly important to reduce the pre-existing cylindrical power. In our study the toric lens provided rotational stability in the capsular bag with an average lens rotation of less than 3.3±2.5 degrees from the lens initial placement at 3 months after surgery. This study did not evaluate the incidence of later postoperative rotation because previous trials found good long-term rotational stability of toric IOLs 7, Our results revealed that both IOLs provided good BCVA (about 20/20). Mendicute et al. 3 using the AcrySof toric reported similar values and percentages of binocular BCVA in 30 eyes at 3 month post-surgery (mean BCVA of 0.02±0.05 logmar; 100% of the patients with 20/25 or better). Zuberbuhler et al. 16 on a sample of 44 eyes implanted with the same IOL at 3 months found a mean BCVA of 0.01±0.11 logmar (about 20/20); and recently, Chang 19 reported that the 94% of a sample of 50 patients achieved a BCVA of 20/40 or better. Cadarso et al.(29) at 6 months and Mester et al.(30) at 6 weeks in 30 and 52 eyes implanted with the AcrySof IQ aspheric IOL, respectively, reported that 100% of the patients achieved BCVA of 20/25 or better (logmar 0.1 and -0.03±0.15, respectively). Different authors 21-24,26-30 compared the results of BCVA in patients implanted with the AcrySof IQ aspheric IOL with those implanted with the AcrySof Natural spherical IOL and none found differences statistically significant between both IOLs. Probably the visual performance metrics used were not accurate enough to detect subtle visual changes resulting from spherical aberration reduction by asphericity. In relation to the CS our results revealed photopic CSFs in both groups within the normal range (see Figure 1). Comparing both lenses we found similar photopic CS for the toric and aspheric IOLs at 3 month post-surgery without statistically significant differences at any spatial frequency analysed (p>0.01). From seven studies reporting photopic CS (85 cd/m 2 ) with the AcrySof IQ IOL, 3 didn t find statistically significant differences at any spatial frequency compared with the SN60AT IOL 21,24,25 and 4 revealed differences 23,26,27,30 at 3 cpd 30, 6 cpd 23,30, 12 cpd 23, and 18 cpd 23,26,27. Six studies evaluated the AcrySof IQ compared with SN60AT under mesopic conditions 21,23, All found significant differences specially at 1.5 cpd 23,26,27,30, 3 cpd 21,23,26-28, 6 cpd 23,29, 12 cpd 23,26-28, and 18 cpd 21,23, Our CS results with AcrySof IQ were similar to the others but the differences in conditions and measure systems between studies may play a role in the differences found. No comparison with previous studies about the CS of the Table 2: Ocular spherical aberration values Z(4,0) with AcrySof toric (SN60Tx) and AcrySof IQ (SN60WF) IOLs for 6 mm of pupil AcrySof Toric IOL (SN60Tx) AcrySof IQ IOL (SN60WF) P value Preoperative Spherical aberration Z(4,0) ± ± Postoperative Spherical aberration Z(4,0) ± ± x 10-5 IOL = intraocular lens; means (µm) ± standard deviation.

5 72 COMPARISON OF CONTRAST SENSITIVITY BETWEEN TORIC AND ASPHERIC IOLs AcrySof toric IOL is possible because this is the first study that evaluates it. The ocular SA for a 6 mm pupil found was 0.216±0.047 µm for the AcrySof IQ group and 0.540±0.887 µm for the AcrySof Toric group (p=3.021 x 10-5 ). Rocha et al. 21 showed a mean value of SA of 0.24 ±0.04 µm for a 5 mm pupil at 3 months with the AcrySof IQ. Cadarso et al. 29 found an ocular SA of 0.114±0.147 µm in 20 eyes for a 6 mm pupil at 6 months implanted with the AcrySof IQ. No comparison with previous studies about the SA of the AcrySof toric IOL is possible because this is the first study that evaluates it. We have found that the SA was significantly lower in those eyes implanted with the AcrySof Natural IQ IOL. Marcos et al. 31 found that the tolerance to defocus was significantly higher with spherical IOLs than with aspherical IOLs; it was necessary to add 1.5 D with the spherical IOL and 1.1 D with the aspherical IOL to make the 20/20 line illegible on simulation. Recently, Rocha et al. 22 concluded that the reduction in SA after aspherical IOL implantation may degrade distance-corrected near visual acuity and intermediate visual acuity. They point out that residual SA can improve depth of focus and that the tolerance to defocus seems to be higher in eyes with a spherical IOL than in eyes with an aspherical IOL. However, it must be kept in mind that this refers to a monofocal IOL that was not designed to provide a large depth of focus, as are pseudoaccommodating IOLs. From a theoretical point of view, an aspheric IOL design improves the optical quality and therefore, the visual performance in a patient. However, in our study, the SA reduction achieved in those eyes implanted with the aspheric IOL does not correlate with an improvement in the mesopic CSF. We have to note that we didn t control the real pupil size of our patients and then differences among eyes may overlap the role of the aspheric design for large pupils. SA was measured for a 6 mm pupil but we cannot be sure that the real pupil size of those patients would be of 6 mm under mesopic conditions. Alfonso et al. 32 measured the pupil size in 650 eyes (61.2±9.3 years old) under the same lighting conditions (5 cd/m 2 ) reporting a mean value of 5.4±0.7 mm. 0.6 mm of difference from this mean value and the pupil size used to compute the SA in our study may be responsible to not report differences in the mesopic CSF between both lenses. In conclusion, both AcrySof spherical toric IOL and AcrySof aspheric IOL provided good visual acuity results. Lower SA was found in those eyes implanted with the aspheric IOL in relation to the spherical model, although, no differences were achieved in visual acuity, and photopic and mesopic CS between lenses. Surgeons should consider that patients may benefit from aspheric designs (i.e. reduction of the central thickness of the lens). Custom selection of the asphericity of the lens for coupling with the corneal SA may reduce highly the ocular SA and then expect a visual performance improvement in those patients implanted with aspheric IOLs. Future studies, should consider direct comparison between spherical and aspheric toric IOLs to analyze properly the benefit in visual performance. SYNOPSIS Acrysof IQ IOL reduces the spherical aberration more than Acrysof Toric IOL but no differences were achieved in Visual Acuity, photopic and mesopic contrast sensitivity between lenses. REFERENCES 1. Hoffer KJ. Biometry of 7500 cataractous eyes. Am J Ophthalmol 1980; 90: ; correction López-Gil N, Montes-Micó R. New intraocular lens for achromatizing the human eye. J Cataract Refract Surg 2007; 33: Mendicute J, Irigoyen C, Aramberri J, Ondarra A, Montés- Micó R. Foldable toric intraocular lens for astigmatism correction in cataract patients. J Cataract Refract Surg. 2008; 34: Grabow HB. Early results with foldable toric IOL implantation. Eur J Implant Refract Surg 1994; 6: Werblin TP. Do three-piece PMMA IOLs rotate after implantation in the capsular bag? J Refract Surg 1995; 11: Sun X-Y, Vicary D, Montgomery P, Griffiths M. Toric intraocular lenses for correcting astigmatism in 130 eyes. Ophthalmology 2000; 107: Ruhswurm I, Scholz U, Zehetmayer M, et al. Astigmatism correction with a foldable toric intraocular lens in cataract patients. J Cataract Refract Surg 2000; 26: Leyland M, Zinicola E, Bloom P, Lee N. Prospective evaluation of a plate haptic toric intraocular lens. Eye 2001; 15: Gills JP, Van der Karr M, Cherchio M. Combined toric intraocular lens implantation and relaxing incisions to reduce high preexisting astigmatism. J Cataract Refract Surg 2002; 28: Viestenz A, Seitz B, Langenbucher A. Evaluating the eye s rotational stability during standard photography; effect of determining the axial orientation of toric intraocular lenses. J Cataract Refract Surg 2005; 31: Weinand F, Jung A, Stein A, et al. Rotational stability of a singlepiece hydrophobic acrylic intraocular lens: new method for highprecision rotation control. J Cataract Refract Surg 2007; 33: Strenn K, Menapace R, Vass C: Capsular bag shrinkage after implantation of an open-loop silicone lens and a poly(methyl methacrylate) capsule tension ring. J Cataract Refract Surg 1997; 23: Sanders DR, Grabow HB, Shepherd J: The toric IOL. In Sutureless Cataract Surgery; An Evolution Toward Minimally Invasive Technique Edited by: Gills JP, Martin RG, Sanders DR. Thorofare, NJ, Slack; 1992; He JC, Gwiazda J, Thorn F, Held R. Wave-front aberrations in the anterior corneal surface and the whole eye. J Opt Soc Am A Opt Image Sci Vis. 2003; 20: Sun X-Y, Vicary D, Montgomery P, Griffiths M. Toric intraocular lenses for correcting astigmatism in 130 eyes.

6 COMPARISON OF CONTRAST SENSITIVITY BETWEEN TORIC AND ASPHERIC IOLs 73 Ophthalmology 2000; 107: ; discussion by RM Kershner, Zuberbuhler B, Signer T, Gale R, Haefliger E. Rotational stability of the AcrySof SA60TT toric intraocular lenses: A cohort study. BMCOphthalmology 2008; 8: Patel CK, Ormonde S, Rosen PH, Bron AJ. Postoperative intraocular lens rotation; a randomized comparison of plate and loop haptic implants. Ophthalmology 1999; 106: ; discussion by DJ Apple, Bauer N, De Vries N, Webers C, Hendrikse F, Nuijts R, Astigmatism management in cataract surgery with the AcrySof toric intraocular lens. J Cataract Refract Surg 2008; 34: Chang DF. Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses. J Cataract Refract Surg 2008; 34: Hill W. Expected effects of surgically induced astigmatism on AcrySof toric intraocular lens results. J Cataract Refract Surg 2008; 34: Rocha KM, Soriano ES, Chalita MR, Yamada AC, Bottós K, Bottós J, Morimoto L, Nose W. Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study. Am J Ophthalmol 2006; 142: Rocha KM, Soriano ES, Chamon W, Chalita MR, Nose W. Spherical aberration and depth of focus in eyes implanted with aspheric and spherical intraocular lenses; a prospective randomized study. Ophthalmology 2007; 114: Caporossi A, Martone G, Casprini F, Rapisarda L. Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes. J Refract Surg 2007; 23: Sandoval HP, Fernández de Castro LE, Vroman DT, Solomon KD. Comparison of visual outcomes, photopic contrast sensitivity, wavefront analysis, and patient satisfaction following cataract extraction and IOL implantation: aspheric vs spherical acrylic lenses. In press, Eye Awwad ST, Lehmann JD, McCulley JP, Bowman RW. A comparison of higher order aberrations in eyes implanted with Acry-Sof IQ SN60WF and AcrySof SN60AT intraocular lenses. Eur J Ophthalmol 2007; 17: Pandita D, Raj SM, Vasavada VA, Vasavada VA, Kazi NS, Vasavada AR. Contrast sensitivity and glare disability after implantation of AcrySof IQ Natural aspherical intraocular lens: prospective randomized masked clinical trial. J Cataract Refract Surg 2007; 33: Tzelikis PF, Akaishi L, Trindade FC, Boteon JE. Ocular aberrations and contrast sensitivity after cataract surgery with AcrySof IQ intraocular lens implantation; clinical comparative study. J Cataract Refract Surg 2007; 33: Awwad ST, Warmerdam D, Bowman RW, Dwarakanathan S, Cavanagh HD, McCulley JP. Contrast sensitivity and higher order aberrations in eyes implanted with Acrysof IQ SN60WF and AcrySof SN60AT intraocular lenses. J Refract Surg 2008; 24: Cadarso L, Iglesias A, Ollero A, Pita B, Montés-Micó R. Postoperative optical aberrations in eyes implanted with AcrySof spherical and aspheric intraocular lenses. J Refract Surg. 2008; 24: Mester U, Kaymak H. Comparison of the AcrySof IQ aspheric blue light filter and the Acrysof SA60AT intraocular lenses. J Refract Surg. 2008; 24: Marcos S, Barbero S, Jiménez-Alfaro I. Optical quality and depth-of-field of eyes implanted with spherical and aspheric intraocular lenses. J Refract Surg 2005; 21: Alfonso JF, Fernández-Vega L, Baamonde B, Montés-Micó R. Prospective visual evaluation of apodized diffractive intraocular lenses. J Cataract Refract Surg. 2007; 33: First author: Francisco Pastor-Pascual, PhD Fundación Oftalmológica del Mediterráneo. Valencia, Spain

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most Simulated vision. Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most The aspheric design of the AcrySof IQ IOL results in improved clarity and image quality. The

More information

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes European Journal of Ophthalmology / Vol. 18 no. 5, 2008 / pp. 728-732 Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes M. RĘKAS, K. KRIX-JACHYM, B.

More information

Aberrations Before and After Implantation of an Aspheric IOL

Aberrations Before and After Implantation of an Aspheric IOL Ocular High Order Aberrations Before and After Implantation of an Aspheric IOL Fabrizio I. Camesasca, MD Massimo Vitali, Orthoptist Milan, Italy I have no financial interest to disclose Wavefront Measurement

More information

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Seema Somani PhD, Ashley Tuan OD, PhD, and Dimitri Chernyak PhD VISX Incorporated, 3400 Central Express Way, Santa Clara, CA

More information

Analysis of the possible benefits of aspheric intraocular lenses: Review of the literature

Analysis of the possible benefits of aspheric intraocular lenses: Review of the literature REVIEW/UPDATE Analysis of the possible benefits of aspheric intraocular lenses: Review of the literature Robert Montés-Micó, OD, MPhil, PhD, Teresa Ferrer-Blasco, OD, MSc, PhD, Alejandro Cerviño, OD, PhD

More information

Dr. Magda Rau Eye Clinic Cham, Germany

Dr. Magda Rau Eye Clinic Cham, Germany 3 and 6 Months clinical Results after Implantation of OptiVis Diffractive-refractive Multifocal IOL Dr. Magda Rau Eye Clinic Cham, Germany Refractive zone of Progressive power for Far to Intermediate

More information

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO Ahmad-Reza Baghi, MD; Mohammad-Reza Jafarinasab, MD; Hossein Ziaei, MD; Zahra Rahmani, MD Shaheed Beheshti Medical University, Tehran,

More information

ROTATIONAL STABILITY MAKES THE DIFFERENCE

ROTATIONAL STABILITY MAKES THE DIFFERENCE The Bi-Flex platform the proven platform of Excellence 01 Proven Stability less than 02 Optimal biomaterials 2 degrees long term rotation 03 Posterior Toric Lens surface with marks indicating the flat

More information

University of Groningen. Young eyes for elderly people van Gaalen, Kim

University of Groningen. Young eyes for elderly people van Gaalen, Kim University of Groningen Young eyes for elderly people van Gaalen, Kim IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the

More information

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens ARTICLE Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens José F. Alfonso, MD, PhD, Luis Fernández-Vega, MD, PhD, M. Begoña

More information

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s. Instruction course: Refining the Refractive Error After Premium IOL s. Senior Instructor: Mounir Khalifa, MD Instructors: David Hardten,MD Scott MacRea,MD Matteo Piovella,MD Dr. Khalifa: Causes of refractive

More information

Objective Analysis of Toric Intraocular Lenses. Affiliation (all authors): Aston University, School of Life and Health Sciences, Ophthalmic

Objective Analysis of Toric Intraocular Lenses. Affiliation (all authors): Aston University, School of Life and Health Sciences, Ophthalmic Title: Objective Analysis of Toric Intraocular Lens Rotation and Centration Running Head: Objective Analysis of Toric Intraocular Lenses Authors: James S. Wolffsohn, PhD Phillip J. Buckhurst, BSc Affiliation

More information

Contrast Sensitivity after Refractive Lens Exchange with A Multifocal Diffractive Aspheric Intraocular Lens

Contrast Sensitivity after Refractive Lens Exchange with A Multifocal Diffractive Aspheric Intraocular Lens Contrast Sensitivity after Refractive Lens Exchange with A Multifocal Diffractive Aspheric Intraocular Lens Teresa Ferrer-Blasco, PhD Santiago García-Lázaro, PhD César Albarrán-Diego, MSc 3 Lurdes Belda-Salmerón,

More information

Unique Aberration-Free IOL: A Vision that Patients

Unique Aberration-Free IOL: A Vision that Patients Unique Aberration-Free IOL: A Vision that Patients Can Appreciate An Aspheric Optic for Improved Quality of Vision n Traditional spherical IOLs create Bilateral implantation study spherical aberration

More information

Long-term quality of vision is what every patient expects

Long-term quality of vision is what every patient expects Long-term quality of vision is what every patient expects Innovative combination of HOYA technologies provides: 1-piece aspheric lens with Vivinex hydrophobic acrylic material Unique surface treatment

More information

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university IOL Types Hazem Elbedewy M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university Artificial intraocular lenses are used to replace the eye natural lens when it has been removed during cataract surgery.

More information

Raise your expectations. Deliver theirs.

Raise your expectations. Deliver theirs. 66 EXTENDED RANGE OF VISION MONOFOCAL-LIKE DISTANCE Raise your expectations. Deliver theirs. Now you can give your patients the best of both worlds with the first and only hybrid designed monofocal-multifocal

More information

Improving Lifestyle Vision. with Small Aperture Optics

Improving Lifestyle Vision. with Small Aperture Optics Improving Lifestyle Vision with Small Aperture Optics The Small Aperture Premium Lens Solution The IC-8 small aperture intraocular lens (IOL) is a revolutionary lens that extends depth of focus by combining

More information

Roadmap to presbyopic success

Roadmap to presbyopic success Roadmap to presbyopic success Miltos O Balidis MD, PhD, FEBOphth, ICOphth Early experience with Presbyopic correction 2003 Binocular Distance-Corrected Intermediate and Near Vision Binocular Distance-Corrected

More information

COMPARISON OF THE MEDICONTUR 860FAB

COMPARISON OF THE MEDICONTUR 860FAB COMPARISON OF THE MEDICONTUR 860FAB HYDROPHOBIC IOL AND THE ACRYSOF IQ LONG TERM FOLLOW UP Péter Vámosi MD, Amanda Argay MD, Zsófia Rupnik MD, János Fekete Péterfy Sándor Hospital Budapest, Hungary PREFERENCE

More information

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up Antonio Mocellin, MD & Matteo Piovella, MD CMA, Centro di Microchirurgia Ambulatoriale Monza (Milan) Italy Dr Piovella

More information

Visual Simulation: application to monofocal intraocular lens analysis

Visual Simulation: application to monofocal intraocular lens analysis ARTICLE Visual Simulation: application to monofocal intraocular lens analysis Alberto Domínguez Vicent, OD; Cari Pérez-Vives, MSc; Lurdes Belda-Salmerón, MSc; César Albarrán-Diego, MSc; Santiago García-Lázaro,

More information

Postoperative Wavefront Analysis and Contrast Sensitivity of a Multifocal Apodized Diffractive IOL (ReSTOR) and Three Monofocal IOLs

Postoperative Wavefront Analysis and Contrast Sensitivity of a Multifocal Apodized Diffractive IOL (ReSTOR) and Three Monofocal IOLs Postoperative Wavefront Analysis and Contrast Sensitivity of a Multifocal Apodized Diffractive IOL (ReSTOR) and Three Monofocal IOLs Karolinne Maia Rocha, MD; Maria Regina Chalita, MD; Carlos Eduardo B.

More information

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric. NOW Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers Accommodating. Aberration Free. Aspheric. Accommodation Meets Asphericity in AO Merging Innovation & Proven Design The

More information

Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation

Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation J CATARACT REFRACT SURG - VOL 31, SEPTEMBER 2005 Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation Antonio Rodríguez-Galietero, MD, PhD, FEBO,

More information

Clinical Evaluation 3-month Follow-up Report

Clinical Evaluation 3-month Follow-up Report Clinical Evaluation 3-month Follow-up Report Of SeeLens HP Intraocular Lens 27 December 2010 version 1.1 1of 16 Table of Contents TABLE OF CONTENTS... 1 OBJECTIVES... 2 EFFICACY AND SAFETY ASSESSMENTS...

More information

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Premium Trifocal MICS OVDs IOLs AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients The moment you help your patients

More information

Evolution of Diffractive Multifocal Intraocular Lenses

Evolution of Diffractive Multifocal Intraocular Lenses Evolution of Diffractive Multifocal Intraocular Lenses Wavefront Congress February 24, 2007 Michael J. Simpson, Ph.D. Alcon Research, Ltd., Fort Worth, Texas Presentation Overview Multifocal IOLs two lens

More information

Comparison of Visual Acuity, Contrast Sensitivity and Spherical Aberration after Implantation of Aspheric and Spheric Intraocular Lenses

Comparison of Visual Acuity, Contrast Sensitivity and Spherical Aberration after Implantation of Aspheric and Spheric Intraocular Lenses Comparison of Visual Acuity, Contrast Sensitivity and Spherical Aberration after Implantation of Aspheric and Spheric Intraocular Lenses Mohammad Nasser Hashemian, MD 1 Morteza Movassat, MD 2 Abdolreza

More information

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1 The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1 The clear choice for consistent visual excellence. For over 165 years Bausch

More information

Prospective sual evaluation of apodized diffractive intraocular lenses

Prospective sual evaluation of apodized diffractive intraocular lenses See discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/6251759 Prospective sual evaluation of apodized diffractive intraocular lenses ARTICLE in JOURNAL

More information

The Blueprint for Improved Image Quality

The Blueprint for Improved Image Quality Insert to January 2009 The Blueprint for Improved Image Quality The function and design of the AcrySof IQ IOL. Supported by an educational grant from Alcon Laboratories, Inc. The Function and Design of

More information

Comparison of Contrast Sensitivity, Higher- Order Aberrations and Subjective Visual Function after Different Aspheric Intraocular Lenses Implantation

Comparison of Contrast Sensitivity, Higher- Order Aberrations and Subjective Visual Function after Different Aspheric Intraocular Lenses Implantation Thai J Ophthalmol Vol. 25 No. 2 July-December 20 9 Original Article/π æπ åμâπ Comparison of Contrast Sensitivity, Higher- Order Aberrations and Subjective Visual Function after Different Aspheric Intraocular

More information

University of Groningen. Young eyes for elderly people van Gaalen, Kim

University of Groningen. Young eyes for elderly people van Gaalen, Kim University of Groningen Young eyes for elderly people van Gaalen, Kim IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the

More information

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Premium Trifocal MICS OVDs IOLs NEW AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Trifocal toric IOL The moment

More information

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE 7 DO IT. TRIFOCAL PERFORMANCE & GLASS INDEPENDENCY UNCOMPROMISED CONTRAST

More information

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision Multifocal Maximum Light Transmission Pupil-independent Light Distribution Better Visual Quality Increased Contrast Sensitivity 3.75D Near Addition Improved Intermediate Vision Visual Performance After

More information

Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions

Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions ARTICLE Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions Francisco Poyales, MD 1 ; Nuria Garzón, OD, MSc 1 ; Pedro Caro, MD 1 ; Oscar

More information

Clinical Update for Presbyopic Lens Options

Clinical Update for Presbyopic Lens Options Clinical Update for Presbyopic Lens Options Gregory D. Searcy, M.D. Erdey Searcy Eye Group Columbus, Ohio The Problem = Spherical Optics Marginal Rays Spherical IOL Light Rays Paraxial Rays Spherical Aberration

More information

Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium

Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage B-Flex Multifocal Dr Emmanuel Van Acker Belgium Comparison of clinical outcomes and patient satisfaction after implantation of two different

More information

Update on Aspheric IOL Technology

Update on Aspheric IOL Technology Peer-Reviewed Literature: Update on Aspheric IOL Technology Editor: Ming Wang, MD, PhD, Clinical Associate Professor of Ophthalmology at the University of Tennessee and Director of the Wang Vision Institute

More information

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results Matteo Piovella MD & Barbara Kusa MD CMA, Centro di Microchirurgia Ambulatoriale

More information

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)? Wavefront-Guided Optics in Clinic: Financial Disclosures The New Frontier November 4, 2017 Matthew J. Kauffman, OD, FAAO, FSLS STAPLE Program Soft Toric and Presbyopic Lens Education Gas Permeable Lens

More information

Treatment of Presbyopia during Crystalline Lens Surgery A Review

Treatment of Presbyopia during Crystalline Lens Surgery A Review Treatment of Presbyopia during Crystalline Lens Surgery A Review Pierre Bouchut Bordeaux Ophthalmic surgeons should treat presbyopia during crystalline lens surgery. Thanks to the quality and advancements

More information

Pichit Naripthaphan MD*, Pongsak Pachimkul MD*, Somporn Chantra MD*

Pichit Naripthaphan MD*, Pongsak Pachimkul MD*, Somporn Chantra MD* Comparison of Visual Outcomes for Aspheric and Spherical Toric Intraocular Lens Implantation in Cataract Patients with Pre-Existing Corneal Astigmatism: A Randomized Control Trial J Med Assoc Thai 2014;

More information

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects Published on Points de Vue International Review of Ophthalmic Optics () Home > Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects Multifocal Intraocular Lenses for

More information

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses SEE BEYOND WITH FULLRANGE OPTICS Developed by Hanita Lenses SEE beyond with FullRange optics FullRange optic lenses are proven, highlyreliable and safe intraocular lenses designed to provide a solution

More information

Effect of an aspheric intraocular lens on the ocular wave-front adjusted for pupil size and capsulorhexis size

Effect of an aspheric intraocular lens on the ocular wave-front adjusted for pupil size and capsulorhexis size Effect of an aspheric intraocular lens on the ocular wave-front adjusted for pupil size and capsulorhexis size Alja Crnej, 1 Wolf Buehl, 2 Roman Greslechner, 2 Nino Hirnschall 1,3 and Oliver Findl 1,3

More information

Objective and subjective outcomes in comparing three different aspheric intraocular lens implants with their spherical counterparts

Objective and subjective outcomes in comparing three different aspheric intraocular lens implants with their spherical counterparts (2009) 23, 877 883 & 2009 Macmillan Publishers Limited All rights reserved 0950-222X/09 $32.00 www.nature.com/eye Objective and subjective outcomes in comparing three different aspheric intraocular lens

More information

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II Edoardo A. Ligabue, MD; Cristina Giordano, OD ABSTRACT PURPOSE: To present the use of the point spread function (PSF)

More information

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN Financial Disclosure Advanced Medical Optics Allergan Bausch & Lomb PowerVision Revision Optics

More information

Refractive Power / Corneal Analyzer. OPD-Scan III

Refractive Power / Corneal Analyzer. OPD-Scan III Refractive Power / Corneal Analyzer OPD-Scan III Comprehensive Vision Analysis and NIDEK, a global leader in ophthalmic and optometric equipment, has created the OPD-Scan III, the third generation aberrometer

More information

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12 Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works How the Eye Works 3 How the eye works Light rays

More information

Advanced Technology IOLs

Advanced Technology IOLs Introduction Advanced Technology IOLs Stephen V. Scoper, MD Virginia Eye Consultants 2013 Cataract surgery has a refractive element Patient expectations are increased Close is no longer good enough The

More information

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs Product Portfolio Sulcoflex Pseudophakic Supplementary IOLs Sulcoflex Pseudophakic Supplementary IOLs For when compromise is not an option As a cataract and refractive surgeon, achieving the best possible

More information

Principles and clinical applications of ray-tracing aberrometry (Part II)

Principles and clinical applications of ray-tracing aberrometry (Part II) UPDATE/REVIEW Principles and clinical applications of ray-tracing aberrometry (Part II) Alfredo Castillo Gómez, MD, PhD 1 ; Antonio Verdejo del Rey, OD 2 ; Carlos Palomino Bautista, MD 3 ; Ana Escalada

More information

MODERN CATARACT SURGERY AND LENS REplacement

MODERN CATARACT SURGERY AND LENS REplacement Wavefront Analysis and Contrast Sensitivity of Aspheric and Spherical Intraocular Lenses: A Randomized Prospective Study KAROLINNE MAIA ROCHA, MD, EDUARDO S. SORIANO, MD, MARIA REGINA CHALITA, MD, ANA

More information

Evaluate Your Patient s Total Visual System With the OPD-Scan III

Evaluate Your Patient s Total Visual System With the OPD-Scan III 0811_OMD553-3MH.qxd:Layout 1 8/9/11 3:08 PM Page 1 SEPTEMBER 2011 Evaluate Your Patient s Total Visual System With the OPD-Scan III New features benefit you and your patients Complete data for IOL selection

More information

This is the author s version of a work that was submitted/accepted for publication in the following source:

This is the author s version of a work that was submitted/accepted for publication in the following source: This is the author s version of a work that was submitted/accepted for publication in the following source: Atchison, David A. & Mathur, Ankit (2014) Effects of pupil center shift on ocular aberrations.

More information

Effects of Pupil Center Shift on Ocular Aberrations

Effects of Pupil Center Shift on Ocular Aberrations Visual Psychophysics and Physiological Optics Effects of Pupil Center Shift on Ocular Aberrations David A. Atchison and Ankit Mathur School of Optometry & Vision Science and Institute of Health & Biomedical

More information

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES. XtraFocus THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES. CONTENT Based on the well-established principle of pinhole optics, this intraocular implant represents an innovative alternative for the

More information

Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a D3.0 D addition

Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a D3.0 D addition ARTICLE Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a D3.0 D addition Thomas Kohnen, MD, Rudy Nuijts, MD, Pierre Levy, MD, Eduard Haefliger,

More information

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK. Supplement February 2015 Maximising Treatment Outcomes with Premium IOL Technology Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK Sponsored by Introduction Thanks to advances in lens

More information

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision. Product Portfolio Sulcoflex Pseudophakic Supplementary IOLs Your skill. Our vision. Sulcoflex Pseudophakic Supplementary IOLs For when compromise is not an option As a cataract and refractive surgeon,

More information

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer Wave Front Topography ReSeeVit Evolution Topography Module for Modi Topographer Introduction The aberrations in the central optical zone have a greater effect than those closer to the edge. From an optical

More information

Surgical data reveals that Q-Factor is important for good surgical outcome

Surgical data reveals that Q-Factor is important for good surgical outcome Surgical data reveals that Q-Factor is important for good surgical outcome Michael Mrochen, PhD Michael Bueeler, PhD Tobias Koller, MD Theo Seiler, MD, PhD IROC AG Institut für Refraktive und Ophthalmo-Chirurgie

More information

Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens

Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens Journal of the Korean Physical Society, Vol. 49, No. 1, July 2006, pp. 121 125 Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens

More information

Akreos AO Intraocular Lens

Akreos AO Intraocular Lens Title: Rotational and Centration Stability of the Aspheric Akreos AO Intraocular Lens Running Head: Stability of Akreos AO Intraocular Lens Platform Authors: Phillip J. Buckhurst, BSc James S. Wolffsohn,

More information

Wavefront Aberrations in Eyes With Acrysof Monofocal Intraocular Lenses

Wavefront Aberrations in Eyes With Acrysof Monofocal Intraocular Lenses Wavefront Aberrations in Eyes With Acrysof Monofocal Intraocular Lenses Prema Padmanabhan, MS; Geunyoung Yoon, PhD; Jason Porter, PhD; Srinivas K. Rao, FRCSEd; Roy J, MSc; Mitalee Choudhury, BS ABSTRACT

More information

American National Standard for Ophthalmics. Extended Depth of Focus Intraocular Lenses

American National Standard for Ophthalmics. Extended Depth of Focus Intraocular Lenses January 23, 2018 rev. 7 ----------------------------------------------------------------------------------------------------------------------------- American National Standard (DRAFT) ANSI Z80.35 -----------------------------------------------------------------------------------------------------------------------------

More information

The Aberration-Free IOL:

The Aberration-Free IOL: The Aberration-Free IOL: Advanced Optical Performance Independent of Patient Profile Griffith E. Altmann, M.S., M.B.A.; Keith H. Edwards, BSc FCOptom Dip CLP FAAO, Bausch & Lomb Some of these results were

More information

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language) Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language) LENTIS Mplus - The one -and and-only Non--rotationally Symmetric Multifocal Lens Multi-center

More information

Clinical Evaluation 3-month Follow-up Report

Clinical Evaluation 3-month Follow-up Report Clinical Evaluation 3-month Follow-up Report Of SeeLens AF Intraocular Lens 30 June 2010 version 1.1 1 of 21 Table of Contents: Objectives 2 Medical device specification and administration 4 Methods 9

More information

Optical Connection, Inc. and Ophthonix, Inc.

Optical Connection, Inc. and Ophthonix, Inc. Optical Connection, Inc. and Ophthonix, Inc. Partners in the delivery of nonsurgical vision optimization www.opticonnection.com www.ophthonix.com The human eye has optical imperfections that can not be

More information

Role of Asphericity in Choice of IOLs for Cataract Surgery

Role of Asphericity in Choice of IOLs for Cataract Surgery Role of Asphericity in Choice of IOLs for Cataract Surgery Delhi J Ophthalmol 2015; 25 (3): 185-189 DOI: http://dx.doi.org/10.7869/djo.105 Aman Khanna, Rebika Dhiman, Rajinder Khanna, Yajuvendra Singh

More information

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston Imaging Modalities That Help Maximize Uncorrected Visual Outcomes After Cataract Surgery Dr.BonnieAn Henderson, MD Dr. Kalpana Narendran, DNB Dr.Prabhu vijayaraghavan, M.S, FICO Dr. Sandra Chandramouli,DNB

More information

Accommodating IOL s History and Clinical Management

Accommodating IOL s History and Clinical Management Accommodating IOL s History and Clinical Management Bausch & Lomb Surgical Aliso Viejo, CA Genesis of an Accommodating IOL 1 Observations with Plate IOLs Stuart Cumming 1989 Some plate haptic IOL patients

More information

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12 Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works Light rays enter the eye through the clear cornea,

More information

PreciSAL Preloaded Lens System

PreciSAL Preloaded Lens System ns PreciSAL Preloaded Lens System SAL P302A, SAL P302AC SAL PT302A, SAL PT302AC CAUTION: Federal (USA) law restricts this medical device to the sale by or on the order of a physician. DEVICE DESCRIPTION

More information

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs The TECNIS Portfolio of presbyopia-correcting IOLs empowers you to hand-select a lens that can deliver the visual freedom your patients

More information

THE ASPHERIC PRELOADED INJECTION

THE ASPHERIC PRELOADED INJECTION New from STAAR for Safe and Easy Implantation THE ASPHERIC PRELOADED INJECTION S Y S T E M PRELOADED INJECTION SYSTEM FOR SIMPLE AND EASY IOL DELIVERY SAFE The KS3-Ai features an aspheric IOL preloaded

More information

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening Clinical Applications Corneal Implant Planning The comes with a licensable corneal inlay software module

More information

TRANSLATIONAL SCIENCE. Effect of Crystalline Lens Aberrations on Adaptive Optics Simulation of Intraocular Lenses

TRANSLATIONAL SCIENCE. Effect of Crystalline Lens Aberrations on Adaptive Optics Simulation of Intraocular Lenses TRANSLATIONAL SCIENCE Effect of Crystalline Lens Aberrations on Adaptive Optics Simulation of Intraocular Lenses Eloy A. Villegas, PhD; Silvestre Manzanera, PhD; Carmen M. Lago, MSc; Lucía Hervella, MSc;

More information

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 3,900 116,000 120M Open access books available International authors and editors Downloads Our

More information

Visual Performance after AcrySof ReSTOR Aspheric Intraocular Lens Implantation

Visual Performance after AcrySof ReSTOR Aspheric Intraocular Lens Implantation ORIGINAL ARTICLE J Optom 2008;1:30-35 Visual Performance after AcrySof ReSTOR Aspheric Intraocular Lens Implantation José F. Alfonso 1,2, Luis Fernández-Vega 1,2, Beatriz Valcárcel 1 and Robert Montés-Micó

More information

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL ALL TRIFOCAL IOLS ARE NOT THE SAME! Seamless Vision Near Intermediate Far Light Figure 1: Comparison of MTF Values 1,2 THE WORLD S FIRST AND ONLY

More information

Technicians & Nurses Program

Technicians & Nurses Program ASCRS ASOA Symposium & Congress Technicians & Nurses Program May 6-10, 2016 New Orleans ADVANCED BIOMETRY AND IOL CALCULATIONS Financial Disclosures No relevant disclosures Karen Bachman, COMT, ROUB The

More information

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs The TECNIS portfolio of presbyopia-correcting IOLs empowers you to hand select a lens that can deliver the visual freedom your patients

More information

Customized intraocular lenses

Customized intraocular lenses Customized intraocular lenses Challenges and limitations Achim Langenbucher, Simon Schröder & Timo Eppig Customized IOL what does this mean? Aspherical IOL Diffractive multifocal IOL Spherical IOL Customized

More information

Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS

Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS Cronicon OPEN ACCESS EC OPHTHALMOLOGY Research Article Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS Ahmed Abdelkareem Elmassry*,

More information

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses Bilateral TECNIS MF versus Customized TECNIS MF - REZOOM Achieving Spectacle Independence THE PERFECT SPECTACLE FREE TREATMENT PATIENT SELECTION 1.ARE THEY INTERESTED IN BECOMING SPECTACLE FREE? 2.ARE

More information

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design Contents Basics of asphericity Visual quality and aspheric IOL Features of HOYA ABC Design 2 What is asphericity? Deviating from the spherical

More information

Intraocular lens Difficulties

Intraocular lens Difficulties Intraocular lens Difficulties Sameh Fouda MD, FRCS Assistant Professor Of Ophthalmology Faculty Of Medicine, Zagazig University IOL in history Sir Harold Ridley, in the 1940s,discovered that shards of

More information

Design and qualification of a diffractive trifocal optical profile for intraocular lenses

Design and qualification of a diffractive trifocal optical profile for intraocular lenses LABORATORY SCIENCE Design and qualification of a diffractive trifocal optical profile for intraocular lenses Damien Gatinel, MD, PhD, Christophe Pagnoulle, PhD, Yvette Houbrechts, PhD, Laure Gobin, PhD

More information

VISUAL ACUITY AND IMAGE QUALITY IN FIVE DIFFRACTIVE. Short title: Visual acuity and image quality in five diffractive intraocular lenses

VISUAL ACUITY AND IMAGE QUALITY IN FIVE DIFFRACTIVE. Short title: Visual acuity and image quality in five diffractive intraocular lenses VISUAL ACUITY AND IMAGE QUALITY IN FIVE DIFFRACTIVE INTRAOCULAR LENSES Short title: Visual acuity and image quality in five diffractive intraocular lenses Genís Cardona a, Fidel Vega a, Miguel A. Gil b,

More information

In Vitro Strehl Ratios with Spherical, Aberration-Free, and customized spherical aberration-correcting METHODS

In Vitro Strehl Ratios with Spherical, Aberration-Free, and customized spherical aberration-correcting METHODS In Vitro Strehl Ratios with Spherical, Aberration-Free, Average, and Customized Spherical Aberration-Correcting Intraocular Lenses Stefan Pieh, 1 Werner Fiala, 1 Andre Malz, 2 and Wilhelm Stork 2 PURPOSE.

More information

CLINICAL SCIENCES. Corneal Optical Aberrations and Retinal Image Quality in Patients in Whom Monofocal Intraocular Lenses Were Implanted

CLINICAL SCIENCES. Corneal Optical Aberrations and Retinal Image Quality in Patients in Whom Monofocal Intraocular Lenses Were Implanted CLINICAL SCIENCES Corneal Optical Aberrations and Retinal Image Quality in Patients in Whom Monofocal Intraocular Lenses Antonio Guirao, PhD; Manuel Redondo, PhD; Edward Geraghty; Patricia Piers; Sverker

More information

Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique

Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique Published online: July 21, 2015 1663 2699/15/0062 0239$39.50/0 This is an Open Access article licensed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported license (CC BY-NC)

More information

Clinical Study Effect of Spherical Aberration on the Optical Quality after Implantation of Two Different Aspherical Intraocular Lenses

Clinical Study Effect of Spherical Aberration on the Optical Quality after Implantation of Two Different Aspherical Intraocular Lenses Hindawi Ophthalmology Volume 2017, Article ID 8039719, 6 pages https://doi.org/10.1155/2017/8039719 Clinical Study Effect of Spherical Aberration on the Optical Quality after Implantation of Two Different

More information

The Impact of New Generation Aspherical Soft Contact Lenses on Quality of Vision: A Comparison with Spherical Contact Lenses and Spectacle Correction

The Impact of New Generation Aspherical Soft Contact Lenses on Quality of Vision: A Comparison with Spherical Contact Lenses and Spectacle Correction Deniz Oral, Maryo C. Kohen, Melda Yenerel, Ebru Gorgun, Sule Ziylan, Ferda Ciftci Yeditepe University Faculty of Medicine, Department of Ophthalmology, Istanbul Introduction The correction of higher order

More information