Patent Applied. Magnified image Film surface. The closer the X-ray tube is placed to the work, the higher the magnification power becomes.

Size: px
Start display at page:

Download "Patent Applied. Magnified image Film surface. The closer the X-ray tube is placed to the work, the higher the magnification power becomes."

Transcription

1 REFLOW SCOPE X-RAY

2 CORES has developed on its own a special reflow oven to make the observation of larger works in size; thus,pwbs in A4 size as well as small chips or BGAs can be directly observed as they are being surface-mounted under heated conditions. Patent Applied core9060a, installing an X-ray tube right inside the reflow oven, realizes a high magnification power which has never been achieved by now as the X-ray tube in any conventional X-ray observation equipment is separately placed away from the reflow. CORES has challenged and overthrown this common concept and successfully developed a special X-ray tube and a special reflow, so that the latter can accommodate the former inside its own to achieve the magnification of X200 for observation. Image intensifier tube Magnified image Film surface Geometric magnification = Y2 / Y1 Reflow oven Y2 BGA X-ray tube Y1 Reflow X-ray focus Substrate x-ray tube Heat resistance glass The closer the X-ray tube is placed to the work, the higher the magnification power becomes.

3 core9060a has made it possible for the first time in its class utilizing and combining X-ray with a reflow to provide a maximum geometric magnification of 200 and a maximum monitor magnification of 500. With core9060a, you can monitor the minutest change of BGAs solder balls more clearly under heated conditions and perform more precise analysis of how solder bridges and voids develop than with any conventional X-ray observation instruments. The noises and flickers on the X-ray pictures can be eliminated while they are being taken by way of averaging treatment for their better quality. This averaging treatment can be applied as well after the X-ray pictures are all taken. The brightness and contrast of X-ray images can be easily adjusted using the scroll bars on the Adjust brightness window Five different artificial colors can be freely set, selected and applied to the X-ray pictures on the Set colors window while they are being taken for the better distinction of the details of the pictures. [Adjust brightness window] [Set colors window] Brightness and contrast to be adjusted freely with the scroll bars Click the Apply(A) button to adjust the brightness and contrast while seeing the pictures Brightness Contrast Cancel Apply(A) Artificial colors can be freely selected from among the color dialogue of 5 different ones. The coloring is effective for such pictures that lack in shade distinction. Effect coloring Cancel Apply(A)

4 core9060a clearly captures the way the voids of chips or BGAs develop by taking and recording the animations of solderability at high temperatures at a rate of 30 frames per minute. Connector You can see how voids develop BGA You can see how self-alignments develop Connector You can see how voids develop at high temperatures BGA You can see how self-alignments develop at high temperatures Voids under development Before self-alignment After self-alignment The quality of pictures can be improved by applying the averaging treatment and brightness and contrast adjustment after the pictures are taken as well as while they are being taken. CORES unique filing format, COR enables the improvement of quality of pictures to be feasible even after the pictures are taken. The improvement of still pictures can only be possible when the pictures are being taken. Original animation Average treatment Brightness adjustment Artificial coloring

5 core9060a enables you to select and display on the screen necessary data(on temperature, scale, oxygen density, etc.) obtained in the observation irrespective of whether they are being collected or they have been already collected. Take the following case for instance when you wish to use the animation data of a sample taken under heated conditions (Original animation) for 2 different purposes. One purpose is for you to send this to your R & D division, and the other to use it for your own presentation. Your R & D division may want to see the animation data along with other information, such as controlled temperatures, times elapsed, logger temperatures and scales. (Animation A) You want to use only the animation data in the presentation.( Animation B) Original animation You can select necessary data to display on the screen in the Check box for data indication Check box for data indication Enter a check mark to display controlled temps, Times elapsed, Scales and Profile graph with Logger Channel numbers. Check here Control temp Time elapsed Scale Profile graph Logger 1CH Logger 2CH Logger 3CH Logger 4CH Logger 5CH Logger 6CH Logger 7CH Logger 8CH Animation for R & A division (Animation A) Animation for your presentation (Animation B) The data obtained in the observation can be saved in animations (AVI, COR*,MPG) and in still pictures (BMP, JPEG) with added information on temperatures and times, and be available for use in making reports. COR CORES own special filing format

6 Touch panel window Easy axis operation for fine adjustment The axis controller, similarly to the touch panel, provides much ease and confort in axis control. Axis controller box Handy and portable for rough adjustment of axes The illustrations below show how easy you can control the axes by using either the axis controller box or the touch panel on the monitor screen even if the target moves off the position. The moving speed and amount can be automatically adjusted according to a designated magnification power. Touch panel OR Controller box At high temperatures Work moving off the position due to heat Work moving back to original position manually

7 Pictures are taken automatically on the setting of Teaching mode.* It is very convenient and effective when it comes to observing as many pictures as you want on a particular target work. (* under normal temperature conditions) Data on a maximum of 99 points can be saved in required sequence on the teaching mode, and magnification ratio can be adjusted at each point. core9060a is equipped with various useful measurement tools, which are easily operated by the mouse. Each calculation result is shown on the screens at lower right. Area calculation Area calculation of circles, rectangles and free lines is possible on the screen. Electrolytic condenser Area calculation: Specify the area Wire sweep ratio calculation Wire sweep ratio calculation is possible through measurement of the ends of the wire and the center of the curved lines. Bonding wire Wire sweep ratio calculation: Specify the sweep amount / Present wire sweep ratio: 3.0 % Void ratio calculation Void ratio calculation is possible given the area of the solder ball being 100 % 100% 9% Void ratio calculation: Specify the void circle / Present void ratio: 9 %

8 The temperature can be kept uniform all through inside the reflow by controlling the flow of the heat air from the heaters as illustrated below. CORES own and unique convectional heating method has achieved the realization of thermal environmental conditions similar to those of real reflows which apply lead-free solders and the X-ray observation of target works at high temperature heat time. Reflow furnace Cooling air Heat air Heat resistant glass X-ray tube Sideway view (image) PWB (target work) Patent Applied You can easily create temperature profiles by setting relevant temperatures and times (in second). A temperature profile has a maximum of 16 points to designate each temperature and time. The heated temperature data can be saved in CSV(Exel format). Actual screen display to set a temperature profile Tem profile Camera input Start(S) Stop(T) Record Start(R) Stop(O) Heating Indicate(V) Start(H) Stop(P) Still pictures save(c) Settings Graph(G) Temp Profile(M) Option(I)

9 Voids in BGA solder balls A solder bridge on BGA Voids in connector lead Solderability on connector lead Electrolytic condenser VGA connector

10 Main unit Warning light Main unit door Control box Touch panel 19 monitor monitor (for observation) (for operation) Height 2150mm Printer Temperature regulator Reflow control unit Main switch Key board Mouse Width 2664mm (Depths : Main unit 1335mm Furnished table 800mm) Furnished table core9060a is furnished with a special table for the compact installation of operational tools and devices. Being independent of the main unit, the table can be freely moved to a location allowing you to operate the core9060a more comfortably. Table is freely mobile on casters

11 Please make sure on your own whether you have to get any license from or make any report to your governmental authorities as to your installation and use of any equipment like core9060a. The relevant laws in Japan require the users of core9060a to submit such a report of installation to Labor Standard Bureau in Japan. Any alterations or additions in the specifications that may be required by your applicable governmental rules and regulations will be at your cost. Cores provides Japanese users with statutory educational programs for safety operation of the equipment at the time of its delivery and installation.

12 CORES Corporation Head Office : FurukawadoTsuru-shiYamanashi Pref Japan TEL : FAX :

SMX-1000 Plus SMX-1000L Plus

SMX-1000 Plus SMX-1000L Plus Microfocus X-Ray Inspection Systems SMX-1000 Plus SMX-1000L Plus C251-E023A Taking Innovation to New Heights with Shimadzu X-Ray Inspection Systems Microfocus X-Ray Inspection Systems SMX-1000 Plus SMX-1000L

More information

SATECH INC. The Solutions Provider!

SATECH INC. The Solutions Provider! Quality Verification with Real-time X-ray By Richard Amtower One can look at trends in packaging and assembly and predict that geometries will continue to shrink and PCBs will become more complex. As a

More information

!"#$"%&' ()#*+,-+.&/0(

!#$%&' ()#*+,-+.&/0( !"#$"%&' ()#*+,-+.&/0( Multi Chip Modules (MCM) or Multi chip packaging Industry s first MCM from IBM. Generally MCMs are horizontal or two-dimensional modules. Defined as a single unit containing two

More information

MEASUREMENT CAMERA USER GUIDE

MEASUREMENT CAMERA USER GUIDE How to use your Aven camera s imaging and measurement tools Part 1 of this guide identifies software icons for on-screen functions, camera settings and measurement tools. Part 2 provides step-by-step operating

More information

Melting Point Apparatus

Melting Point Apparatus Melting Point Apparatus Stuart has become the laboratory name in melting points. Offering solutions to determine high accuracy melting points. Stuart has a complete range of melting points, from manual

More information

To See is to Survive!

To See is to Survive! INSPECTION SYSTEMS for the 21 s t Century To See is to Survive! In todayõs highly competitive manufacturing environment, the ability to see and react to hidden production deficiencies, in order to guarantee

More information

GlobiScope Analysis Software for the Globisens QX7 Digital Microscope. Quick Start Guide

GlobiScope Analysis Software for the Globisens QX7 Digital Microscope. Quick Start Guide GlobiScope Analysis Software for the Globisens QX7 Digital Microscope Quick Start Guide Contents GlobiScope Overview... 1 Overview of home screen... 2 General Settings... 2 Measurements... 3 Movie capture...

More information

X-ray Inspection Systems 2D AXI / 3D AXI / WAXI

X-ray Inspection Systems 2D AXI / 3D AXI / WAXI X-ray Inspection Systems 2D AXI / 3D AXI / WAXI SMT / Semiconductor Analysis Equipment High-performance X-ray Inspection System X-eye SF160 Series Non-destructive analysis of semiconductor, SMT, and electron/electric

More information

Flip Chip Installation using AT-GDP Rework Station

Flip Chip Installation using AT-GDP Rework Station Flip Chip Installation using AT-GDP Rework Station Introduction An increase in implementation of Flip Chips, Dies, and other micro SMD devices with hidden joints within PCB and IC assembly sectors requires

More information

μscope Microscopy Software

μscope Microscopy Software μscope Microscopy Software Pixelink μscope Essentials (ES) Software is an easy-to-use robust image capture tool optimized for productivity. Pixelink μscope Standard (SE) Software had added features, making

More information

Bumping of Silicon Wafers using Enclosed Printhead

Bumping of Silicon Wafers using Enclosed Printhead Bumping of Silicon Wafers using Enclosed Printhead By James H. Adriance Universal Instruments Corp. SMT Laboratory By Mark A. Whitmore DEK Screen Printers Advanced Technologies Introduction The technology

More information

Planmeca Romexis. quick guide. Viewer EN _2

Planmeca Romexis. quick guide. Viewer EN _2 Planmeca Romexis Viewer quick guide EN 10029550_2 TABLE OF CONTENTS 1 START-UP OF PLANMECA ROMEXIS VIEWER...1 1.1 Selecting the interface language... 1 1.2 Selecting images...1 1.3 Starting the Planmeca

More information

Standard Operating Procedure

Standard Operating Procedure CENTER FOR NANOSCALE SCIENCE AND ENGINEERING Standard Operating Procedure Microscope Software Brian Wajdyk Page 1 of 6 Important Images are not to be saved to the computer. They will be deleted without

More information

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000 The ideal K-12 science microscope solution User Guide for use with the Nova5000 NovaScope User Guide Information in this document is subject to change without notice. 2009 Fourier Systems Ltd. All rights

More information

Professional Photograph Restoration 50 Points

Professional Photograph Restoration 50 Points Professional Photograph Restoration 50 Points In this tutorial, we'll take an in-depth look at restoring an old torn photograph. Restoring old family photos is something that you can do for your relatives

More information

A Handheld Image Analysis System for Portable and Objective Print Quality Analysis

A Handheld Image Analysis System for Portable and Objective Print Quality Analysis A Handheld Image Analysis System for Portable and Objective Print Quality Analysis Ming-Kai Tse Quality Engineering Associates (QEA), Inc. Contact information as of 2010: 755 Middlesex Turnpike, Unit 3

More information

FLIP CHIP LED SOLDER ASSEMBLY

FLIP CHIP LED SOLDER ASSEMBLY As originally published in the SMTA Proceedings FLIP CHIP LED SOLDER ASSEMBLY Gyan Dutt, Srinath Himanshu, Nicholas Herrick, Amit Patel and Ranjit Pandher, Ph.D. Alpha Assembly Solutions South Plainfield,

More information

PUBLICLY AVAILABLE SPECIFICATION

PUBLICLY AVAILABLE SPECIFICATION PUBLICLY AVAILABLE SPECIFICATION PRE-STANDARD This is a preview - click here to buy the full publication IEC/PAS 62647-23 Edition 1.0 2011-07 colour inside Process management for avionics Aerospace and

More information

ISO 7438 INTERNATIONAL STANDARD. Metallic materials Bend test. Matériaux métalliques Essai de pliage. Second edition

ISO 7438 INTERNATIONAL STANDARD. Metallic materials Bend test. Matériaux métalliques Essai de pliage. Second edition INTERNATIONAL STANDARD ISO 7438 Second edition 2005-06-15 Metallic materials Bend test Matériaux métalliques Essai de pliage Reference number ISO 7438:2005(E) ISO 2005 PDF disclaimer This PDF file may

More information

Advances in X-Ray Technology for Semicon Applications Keith Bryant and Thorsten Rother

Advances in X-Ray Technology for Semicon Applications Keith Bryant and Thorsten Rother Advances in X-Ray Technology for Semicon Applications Keith Bryant and Thorsten Rother X-Ray Champions, Telspec, Yxlon International Agenda The x-ray tube, the heart of the system Advances in digital detectors

More information

Bringing Answers to the Surface

Bringing Answers to the Surface 3D Bringing Answers to the Surface 1 Expanding the Boundaries of Laser Microscopy Measurements and images you can count on. Every time. LEXT OLS4100 Widely used in quality control, research, and development

More information

dlsoft Barcode Analyser By dlsoft

dlsoft Barcode Analyser By dlsoft dlsoft Barcode Analyser By dlsoft This manual was produced using ComponentOne Doc-To-Help. Contents BarAnalyser 1 Introduction... 1 Barcode symbologies... 5 How to use BarAnalyser... 5 Walk through...

More information

Glenbrook presents the RTXfamily: innovative, affordable, upgradable

Glenbrook presents the RTXfamily: innovative, affordable, upgradable Glenbrook presents the RTXfamily: innovative, affordable, upgradable Real-time X-ray inspection systems from the desktop to the production line. Glenbrook Technologies' tradition of innovation in X-ray

More information

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0 DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0 PixeLINK for Microscopy Applications PixeLINK will work with you to choose and integrate the optimal USB 3.0 camera for your microscopy project. Ideal for use

More information

A guide to SalsaJ. This guide gives step-by-step instructions on how to use SalsaJ to carry out basic data analysis on astronomical data files.

A guide to SalsaJ. This guide gives step-by-step instructions on how to use SalsaJ to carry out basic data analysis on astronomical data files. A guide to SalsaJ SalsaJ is free, student-friendly software developed originally for the European Hands- On Universe (EU-HOU) project. It is designed to be easy to install and use. It allows students to

More information

Image Editing and Measurement Software. User Manual

Image Editing and Measurement Software. User Manual Digital Viewer II TM Digital Microscope Image Editing and Measurement Software User Manual Version: 2.1.1.2 1 DIGITAL VIEWER II TM DIGITAL MICROSCOPE... 1 IMAGE EDITING AND MEASUREMENT SOFTWARE... 1 USER

More information

Introduction of IMS Technology for Advanced Solder Bumping on Wafers / Laminates

Introduction of IMS Technology for Advanced Solder Bumping on Wafers / Laminates Introduction of IMS Technology for Advanced Solder Bumping on Wafers / Laminates Science & Technology IBM Research Tokyo Yasumitsu Orii, PhD Senju Metal Industry Co.,TW Deputy General Manager Lewis Huang

More information

IMPAX 6 DISPLAY TOOL LIST

IMPAX 6 DISPLAY TOOL LIST IMPAX 6 DISPLAY TOOL LIST IMPAX 6.0 TOOLS INDEX A Advance by Image Allows you to scroll from one image or frame to the next Advance by Page Pages through images in a large series, one screen at a time

More information

SMT Troubleshooting. Typical SMT Problems For additional process solutions, please refer to the AIM website troubleshooting guide

SMT Troubleshooting. Typical SMT Problems For additional process solutions, please refer to the AIM website troubleshooting guide SMT Troubleshooting Typical SMT Problems For additional process solutions, please refer to the AIM website troubleshooting guide Solder Balling Solder Beading Bridging Opens Voiding Tombstoning Unmelted

More information

USING SIGNATURE IDENTIFICATION FOR RAPID AND EFFECTIVE X-RAY INSPECTION OF BALL GRID ARRAYS

USING SIGNATURE IDENTIFICATION FOR RAPID AND EFFECTIVE X-RAY INSPECTION OF BALL GRID ARRAYS USING SIGNATURE IDENTIFICATION FOR RAPID AND EFFECTIVE X-RAY INSPECTION OF BALL GRID ARRAYS Gil Zweig Glenbrook Technologies, Inc. Randolph, New Jersey USA gzweig@glenbrooktech.com ABSTRACT Although X-ray

More information

SCIENTIFIC INSTRUMENT NEWS. Introduction. Design of the FlexSEM 1000

SCIENTIFIC INSTRUMENT NEWS. Introduction. Design of the FlexSEM 1000 SCIENTIFIC INSTRUMENT NEWS 2017 Vol. 9 SEPTEMBER Technical magazine of Electron Microscope and Analytical Instruments. Technical Explanation The FlexSEM 1000: A Scanning Electron Microscope Specializing

More information

Application Bulletin 240

Application Bulletin 240 Application Bulletin 240 Design Consideration CUSTOM CAPABILITIES Standard PC board fabrication flexibility allows for various component orientations, mounting features, and interconnect schemes. The starting

More information

Ryan - Using the PhotoStitch Wizard

Ryan - Using the PhotoStitch Wizard Ryan - Using the PhotoStitch Wizard This exercise is taken from the PhotoStitch Wizard chapter of the PREMIER+ EMBROIDERY/PREMIER+ EXTRA Reference Guide. Using the PhotoStitch Wizard 1 - Load and Edit

More information

PROFESSIONAL PHOTOGRAPH RESTORATION WORKFLOW

PROFESSIONAL PHOTOGRAPH RESTORATION WORKFLOW PROFESSIONAL PHOTOGRAPH RESTORATION WORKFLOW Tutorial from http://psd.tutsplus.com/ Compiled by INTRODUCTION In this tutorial, we'll take an in-depth look at restoring an old torn photograph.

More information

GE Healthcare. Senographe 2000D Full-field digital mammography system

GE Healthcare. Senographe 2000D Full-field digital mammography system GE Healthcare Senographe 2000D Full-field digital mammography system Digital has arrived. The Senographe 2000D Full-Field Digital Mammography (FFDM) system gives you a unique competitive advantage. That

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded INTERNATIONAL STANDARD ISO 17636 First edition 2003-09-15 Non-destructive testing of welds Radiographic testing of fusionwelded joints Contrôle non destructif des assemblages soudés Contrôle par radiographie

More information

Quintic Software Tutorial 3

Quintic Software Tutorial 3 Quintic Software Tutorial 3 Take a Picture 1 Tutorial 3 Take a Picture Contents Page 1. Photo 2. Photo Sequence a. Add shapes and angles 3. Export Analysis 2 Tutorial 3 Take a Picture 1. Photo Open the

More information

PAINT BORER 518 MC PAINTXPLORER 548

PAINT BORER 518 MC PAINTXPLORER 548 PAINT BORER 518 USB PAINT BORER 518 MC PAINTXPLORER 548 PAINT BORER 518 USB Thickness measurements in accordance with the standardised wedge cut method PAINT BORER 518 MC PAINTXPLORER 548 testing equipment

More information

Page 21 GRAPHING OBJECTIVES:

Page 21 GRAPHING OBJECTIVES: Page 21 GRAPHING OBJECTIVES: 1. To learn how to present data in graphical form manually (paper-and-pencil) and using computer software. 2. To learn how to interpret graphical data by, a. determining the

More information

1. What is SENSE Batch

1. What is SENSE Batch 1. What is SENSE Batch 1.1. Introduction SENSE Batch is processing software for thermal images and sequences. It is a modern software which automates repetitive tasks with thermal images. The most important

More information

When asked this riddle, 80% of kindergarten kids got the answer compared to 17% of Stanford University seniors.

When asked this riddle, 80% of kindergarten kids got the answer compared to 17% of Stanford University seniors. When asked this riddle, 80% of kindergarten kids got the answer compared to 17% of Stanford University seniors. What is greater than God, More evil than the devil, The poor have it, The rich need it, And

More information

ISO/IEC TS TECHNICAL SPECIFICATION

ISO/IEC TS TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION This is a preview - click here to buy the full publication ISO/IEC TS 24790 First edition 2012-08-15 Corrected version 2012-12-15 Information technology Office equipment Measurement

More information

Motic Live Imaging Module. Windows OS User Manual

Motic Live Imaging Module. Windows OS User Manual Motic Live Imaging Module Windows OS User Manual Motic Live Imaging Module Windows OS User Manual CONTENTS (Linked) Introduction 05 Menus, bars and tools 06 Title bar 06 Menu bar 06 Status bar 07 FPS 07

More information

MN-ISD-A100-E ISD-A100 VIDEO MEASURING MICROSCOPE OPERATION MANUAL

MN-ISD-A100-E ISD-A100 VIDEO MEASURING MICROSCOPE OPERATION MANUAL MN-ISD-A100-E www. insize. com ISD-A100 VIDEO MEASURING MICROSCOPE OPERATION MANUAL V1 Description 1 2 ISD-A100 is a precise and excellent effective measuring instrument integrating optic, mechanic and

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

ColorCode 3-D Editor Version 1.2 Manual. Make ColorCode 3-D, Auto 3-D and Standard 3-D images on your PC by ColorCode 3-D, Denmark!!!

ColorCode 3-D Editor Version 1.2 Manual. Make ColorCode 3-D, Auto 3-D and Standard 3-D images on your PC by ColorCode 3-D, Denmark!!! US Patent No. 6,687,003 AU Patent No. 763370 EP Patent No. 1131658 ColorCode 3-D Editor Version 1.2 Manual Make ColorCode 3-D, Auto 3-D and Standard 3-D images on your PC 2012 by ColorCode 3-D, Denmark!!!

More information

Installation & User Manual Micro-Image Capture 7

Installation & User Manual Micro-Image Capture 7 Installation & User Manual Micro-Image Capture 7 Ver1.2016 Product Warranty Quality Assurance Every Micro-Image Capture system passes quality assurance tests including focus, resolution quality and mechanical

More information

First English edition for Ulead COOL 360 version 1.0, February 1999.

First English edition for Ulead COOL 360 version 1.0, February 1999. First English edition for Ulead COOL 360 version 1.0, February 1999. 1992-1999 Ulead Systems, Inc. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any

More information

Table of Contents 1. Image processing Measurements System Tools...10

Table of Contents 1. Image processing Measurements System Tools...10 Introduction Table of Contents 1 An Overview of ScopeImage Advanced...2 Features:...2 Function introduction...3 1. Image processing...3 1.1 Image Import and Export...3 1.1.1 Open image file...3 1.1.2 Import

More information

Optical Inspection Systems

Optical Inspection Systems Optical Inspection Systems Easy Braid s Desoldering Braid Easy Braid s Solder Soakers Easy Braid s Swabs Easy Braid s Wipes Easy Braid s Stencil Rolls EASY BRAID CO. Easy Braid Co. is a manufacturer of

More information

Basic Tutorials Series: Import A Photograph. RenoWorks Support Team Document #HWPRO0003

Basic Tutorials Series: Import A Photograph. RenoWorks Support Team Document #HWPRO0003 Basic Tutorials Series: Import A Photograph RenoWorks Support Team Document #HWPRO0003 Import A Photograph 2 1 Import Your Own Photograph The Photo Import Wizard The Photo Import Wizard is the first tool

More information

The Problems. Spheretek Wafer Bumping The Low Cost and Reliable Solution to Production Wafer Packaging

The Problems. Spheretek Wafer Bumping The Low Cost and Reliable Solution to Production Wafer Packaging Spheretek Wafer Bumping The Low Cost and Reliable Solution to Production Wafer Packaging The Problems. Packaging Production engineers and their CFO s have to date been disappointed in the results of their

More information

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY Series 4 CR Fujifilm, the absolute pioneer in digitized medical X-ray imaging advanced into the industrial inspection field

More information

Y.MU 2000 Precise inspection results for sampling and 100% inspection

Y.MU 2000 Precise inspection results for sampling and 100% inspection +++ Technical Data +++ Technical Data +++ Technical Data +++ Technical Data +++ Technical Data +++ Technical Data +++ Technical Data +++ YXLON.Products Y.MU 2000 Precise inspection results for sampling

More information

True 2 ½ D Solder Paste Inspection

True 2 ½ D Solder Paste Inspection True 2 ½ D Solder Paste Inspection Process control of the Stencil Printing operation is a key factor in SMT manufacturing. As the first step in the Surface Mount Manufacturing Assembly, the stencil printer

More information

Module No. # 07 Lecture No. # 35 Vapour phase soldering BGA soldering and De-soldering Repair SMT failures

Module No. # 07 Lecture No. # 35 Vapour phase soldering BGA soldering and De-soldering Repair SMT failures An Introduction to Electronics Systems Packaging Prof. G. V. Mahesh Department of Electronic Systems Engineering Indian Institute of Science, Bangalore Module No. # 07 Lecture No. # 35 Vapour phase soldering

More information

Explore the Art of Detection

Explore the Art of Detection Y.Cougar Basic Microfocus X-ray inspection systems for the electronics industries Explore the Art of Detection Technology with Passion Our specialty: The Art of Detection. Developing outstanding X-ray

More information

Reflow soldering guidelines for surface mounted power modules

Reflow soldering guidelines for surface mounted power modules Design Note 017 Reflow soldering guidelines for surface mounted power modules Introduction Ericsson surface mounted power modules are adapted to the ever-increasing demands of high manufacturability and

More information

Applications Note. Successfully using the Model 8000 NERO dental x-ray machine timer performance. max to evaluate

Applications Note. Successfully using the Model 8000 NERO dental x-ray machine timer performance. max to evaluate Successfully using the Model 8000 NERO dental x-ray machine timer performance max to evaluate Information in this article applies to Model 8000 NERO max firmware release 2.3 or higher. Introduction The

More information

BGA (Ball Grid Array)

BGA (Ball Grid Array) BGA (Ball Grid Array) National Semiconductor Application Note 1126 November 2002 Table of Contents Introduction... 2 Package Overview... 3 PBGA (PLASTIC BGA) CONSTRUCTION... 3 TE-PBGA (THERMALLY ENHANCED

More information

Application Note. Soldering Guidelines for Module PCB Mounting Rev 13

Application Note. Soldering Guidelines for Module PCB Mounting Rev 13 Application Note Soldering Guidelines for Module PCB Mounting Rev 13 OBJECTIVE The objective of this application note is to provide ANADIGICS customers general guidelines for PCB second level interconnect

More information

Toshiba HEK3 0.3 Mp VGA CMOS Image Sensor 0.13 µm Toshiba Process

Toshiba HEK3 0.3 Mp VGA CMOS Image Sensor 0.13 µm Toshiba Process Toshiba HEK3 0.3 Mp VGA CMOS Image Sensor 0.13 µm Toshiba Process Through Silicon Via Process Review For comments, questions, or more information about this report, or for any additional technical needs

More information

1 Scarsdale Road, Don Mills, ON, M3B 2R2 Tel: , Fax:

1 Scarsdale Road, Don Mills, ON, M3B 2R2 Tel: , Fax: 1 Scarsdale Road, Don Mills, ON, M3B 2R2 Tel: 416-445-5500, Fax: 416-445-1170 Montreal: 514-333-0930, Ottawa: 613-723-1828, Winnipeg: 204-895-2037, Calgary: 403-254-0095, Vancouver: 604-270-9538 E-Mail:

More information

Y N C R O S C O P Y A DIVISION OF THE SYNOPTICS GROUP

Y N C R O S C O P Y A DIVISION OF THE SYNOPTICS GROUP S Y N C R O S C O P Y A DIVISION OF THE SYNOPTICS GROUP THE PROBLEM: As a microscopist you often have to work with samples that are difficult to focus. When viewing a 3-D sample using an optical microscope

More information

Lab 2 Assignment Part 2: (Due two weeks following the fluorescence lab) (10 points)

Lab 2 Assignment Part 2: (Due two weeks following the fluorescence lab) (10 points) Lab 2 Assignment Part 2: (Due two weeks following the fluorescence lab) (10 points) Each individual should prepare one set of corresponding phase contrast and fluorescent images and an accompanying figure

More information

BGA inspection and rework with HR 600/2 Failure analysis and assembly repair

BGA inspection and rework with HR 600/2 Failure analysis and assembly repair Even today some assemblies including BGA components still show soldering failures that require as a consequence to rework the BGA. The following example can be seen as a typical case for today s inspection

More information

Version Number_1.8(English Version) Copyright 2011 by Aumed, All rights reserved. Aumed Group Corp.

Version Number_1.8(English Version) Copyright 2011 by Aumed, All rights reserved. Aumed Group Corp. Version Number_1.8(English Version) Copyright 2011 by Aumed, All rights reserved Aumed Group Corp. 3/F Building D,No.31 Jiaoda Dong Road, Haidian District, Beijing 100044 China Tel: 86-10-8288 4173 Fax:

More information

Chip Assembly on MID (Molded Interconnect Device) A Path to Chip Modules with increased Functionality

Chip Assembly on MID (Molded Interconnect Device) A Path to Chip Modules with increased Functionality T e c h n o l o g y Dr. Werner Hunziker Chip Assembly on MID (Molded Interconnect Device) A Path to Chip Modules with increased Functionality The MID (Molded Interconnect Device) technology enables the

More information

ImagesPlus Basic Interface Operation

ImagesPlus Basic Interface Operation ImagesPlus Basic Interface Operation The basic interface operation menu options are located on the File, View, Open Images, Open Operators, and Help main menus. File Menu New The New command creates a

More information

Mighty Scope 5M. Instruction Manual. aveninc.com

Mighty Scope 5M. Instruction Manual. aveninc.com Mighty Scope 5M Instruction Manual aveninc.com Contents Features 2 Specifications 2 Contents 2 PC System Requirements 3 Driver Installation Procedure 3 Getting Started 3 Software Installation (PC) 4 Mighty

More information

MSE 595T Transmission Electron Microscopy. Laboratory III TEM Imaging - I

MSE 595T Transmission Electron Microscopy. Laboratory III TEM Imaging - I MSE 595T Basic Transmission Electron Microscopy TEM Imaging - I Purpose The purpose of this lab is to: 1. Make fine adjustments to the microscope alignment 2. Obtain a diffraction pattern 3. Obtain an

More information

AEC-Q REV A June 1, 2000

AEC-Q REV A June 1, 2000 ATTACHMENT 4 AEC - Q200-004 - REV A MEASUREMENT PROCEDURES FOR RESETTABLE FUSES Page 1 of 19 NOTICE AEC documents contain material that has been prepared, reviewed, and approved through the AEC Technical

More information

How to Create and use Manual Linearization Profiles in Matan PhotoPrint Server

How to Create and use Manual Linearization Profiles in Matan PhotoPrint Server 1 Application Note: #011 Date: Nov. 03, 05 Written By: Eitan Abramovich Approved by: Shay Rosenzweig How to Create and use Manual Linearization Profiles in Matan PhotoPrint Server Introduction When printing

More information

XT V Series. X-ray and CT technology for electronics inspection. nikon metrology I vision beyond precision

XT V Series. X-ray and CT technology for electronics inspection. nikon metrology I vision beyond precision XT V Series X-ray and CT technology for electronics inspection nikon metrology I vision beyond precision X-ray electronics inspection made easy Today there is a growing demand for flexible, highresolution

More information

QAQC LAB 589 Rappahannnock Drive White Stone Va TEL (866)

QAQC LAB 589 Rappahannnock Drive White Stone Va TEL (866) OCCHIO Pharma CLICK FOR PRODUCT DEMO 400 OCCHIO Pharma O. O. O. O. OCCHIO Pharma 4 G 00 NANO OCCHIO 500 Occhio 500nano TECHNICAL DATASHEET Reference code: OCC023 Occhio500nano Technical specifications

More information

Laser Scanning for Surface Analysis of Transparent Samples - An Experimental Feasibility Study

Laser Scanning for Surface Analysis of Transparent Samples - An Experimental Feasibility Study STR/03/044/PM Laser Scanning for Surface Analysis of Transparent Samples - An Experimental Feasibility Study E. Lea Abstract An experimental investigation of a surface analysis method has been carried

More information

X-ray technology for electronics inspection

X-ray technology for electronics inspection X-ray technology for electronics inspection nikon metrology I vision beyond precision X-ray and CT inspection of electronic components Insight into the inside Get the inside picture of printed circuit

More information

HOTBAR REFLOW SOLDERING

HOTBAR REFLOW SOLDERING HOTBAR REFLOW SOLDERING Content 1. Hotbar Reflow Soldering Introduction 2. Application Types 3. Process Descriptions > Flex to PCB > Wire to PCB 4. Design Guidelines 5. Equipment 6. Troubleshooting Guide

More information

Made Easy. Jason Pancoast Engineering Manager

Made Easy. Jason Pancoast Engineering Manager 3D Sketching Made Easy Jason Pancoast Engineering Manager Today I have taught you to sketch in 3D. It s as easy as counting ONE, TWO, FIVE...er...THREE! When your sketch only lives in Y and in X, Adding

More information

Recitation 2 Introduction to Photoshop

Recitation 2 Introduction to Photoshop Recitation 2 Introduction to Photoshop What is Adobe Photoshop? Adobe Photoshop is a tool for creating digital graphics either by starting with a scanned photograph or artwork or by creating the graphics

More information

Texas Instruments TXS0108EZXYR 8 Bit Bidirectional Voltage-Level Translator

Texas Instruments TXS0108EZXYR 8 Bit Bidirectional Voltage-Level Translator Texas Instruments TXS0108EZXYR 8 Bit Bidirectional Voltage-Level Translator 1891 Robertson Road, Suite 500, Ottawa, ON K2H 5B7 Canada Tel: 613-829-0414 www.chipworks.com Some of the information in this

More information

EXC500p-- PATHOLOGY MICROSCOPE. EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE. EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE

EXC500p-- PATHOLOGY MICROSCOPE. EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE. EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE EXC500p-- PATHOLOGY MICROSCOPE EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE The EXC500 Pathology and Laboratory Microscope is the most optically advanced

More information

FPC CONNECTORS Y3FT (0.3 mm pitch) with FPC tabs

FPC CONNECTORS Y3FT (0.3 mm pitch) with FPC tabs AYF31 FPC CONNECTORS FOR FPC CONNECTION FPC CONNECTORS Y3FT (0.3 mm pitch) with FPC tabs (Former Name: YF31) FEATURES 1. Low-profile, space-saving design (pitch: 0.3mm) The 0.9mm height, 3.0mm depth contributes

More information

TECHNICAL SPECIFICATION 2D INSPECTION Description

TECHNICAL SPECIFICATION 2D INSPECTION Description D INSPECTION Description D inspection (Di) ensures the quality of the print by monitoring the printing process Di determines when a stencil clean or paste dispense is required and if licensed, to warn

More information

SCANNING GUIDELINES Peter Thompson (rev. 9/21/02) OVERVIEW

SCANNING GUIDELINES Peter Thompson (rev. 9/21/02) OVERVIEW SCANNING GUIDELINES Peter Thompson (rev. 9/21/02) OVERVIEW WHAT S A SCANNER? A machine that lets you input an image into your and save it as a digital file to be enhanced or altered by image editing software

More information

Powder diffractometer operation instructions D8 Advance with a Cu Kα sealed tube and Lynxeye MARCH 30, 2016

Powder diffractometer operation instructions D8 Advance with a Cu Kα sealed tube and Lynxeye MARCH 30, 2016 Powder diffractometer operation instructions D8 Advance with a Cu Kα sealed tube and Lynxeye MARCH 30, 2016 1 SAFETY. For radiation safety materials refer to http://www.ehs.wisc.edu/raddevices.htm. There

More information

Quick and simple installation and no maintenance needed. 3 Times More affordable Than a normal SEM. Obtaining results in less than 4 minutes

Quick and simple installation and no maintenance needed. 3 Times More affordable Than a normal SEM. Obtaining results in less than 4 minutes INTRODUCTION We believe that every laboratory working in the field of nanotechnology needs an SEM, therefore we would like to introduce to you our IEM series of SEM. In short space of time, our device

More information

PC System Requirement For Dual Microscope

PC System Requirement For Dual Microscope REV.F The 200X digital microscope provides a 10~200X adjustable magnification range, and the 500X microscope provides 500X magnification. The built-in high-performance LEDs can illuminate an object without

More information

Three-Axis Magnetic Sensor HMC1043L

Three-Axis Magnetic Sensor HMC1043L Three-Axis Magnetic Sensor HMC1043L The Honeywell HMC1043L is a miniature three-axis surface mount sensor array designed for low field magnetic sensing. By adding the HMC1043L with supporting signal processing,

More information

Improve SMT Assembly Yields Using Root Cause Analysis in Stencil Design

Improve SMT Assembly Yields Using Root Cause Analysis in Stencil Design Improve SMT Assembly Yields Using Root Cause Analysis in Stencil Design Greg Smith FCT Assembly, Inc. gsmith@fctassembly.com This paper and presentation was first presented at the 2017 IPC Apex Expo Technical

More information

Selective Soldering for Interconnection Technology Used in Enterprise Communication Apparatuses

Selective Soldering for Interconnection Technology Used in Enterprise Communication Apparatuses Selective Soldering for Interconnection Technology Used in Enterprise Communication Apparatuses Mark Woolley, Wesley Brown, and Dr. Jae Choi Avaya Inc. 1300 W 120 th Avenue Westminster, CO 80234 Abstract:

More information

MXR7202G/M. Low Cost, Low Noise ±2 g Dual Axis Accelerometer with Ratiometric Analog Outputs

MXR7202G/M. Low Cost, Low Noise ±2 g Dual Axis Accelerometer with Ratiometric Analog Outputs FEATURES Low cost Resolution better than 1 mg Dual axis accelerometer fabricated on a monolithic CMOS IC On chip mixed signal processing No moving parts; No loose particle issues >50,000 g shock survival

More information

Pitch Reducing Optical Fiber Array Two-Dimensional (2D)

Pitch Reducing Optical Fiber Array Two-Dimensional (2D) PROFA Pitch Reducing Optical Fiber Array Two-Dimensional (2D) Pitch Reducing Optical Fiber Arrays (PROFAs) provide low loss coupling between standard optical fibers and photonic integrated circuits. Unlike

More information

Flip Chip Bonding Using Sony Anisotropic Conductive Film (ACF) FP1526Y

Flip Chip Bonding Using Sony Anisotropic Conductive Film (ACF) FP1526Y Flip Chip Bonding Using Sony Anisotropic Conductive Film (ACF) FP1526Y Purpose: Author: Rekha S. Pai (07/29/03) To use ACF as an interconnection method for attaching dice to substrates. Direct electrical

More information

USING LEICA AS LASER MICRODISSECTION (LMD6000) MICROSCOPE Written By Jungim Hur

USING LEICA AS LASER MICRODISSECTION (LMD6000) MICROSCOPE Written By Jungim Hur USING LEICA AS LASER MICRODISSECTION (LMD6000) MICROSCOPE Written By Jungim Hur Digital Video Camera Eyepieces Laser module Laser safety UV shield Specimen holder Smart move control LEICA CTR6500 electronics

More information

See what you need to see, and see it anywhere.

See what you need to see, and see it anywhere. See what you need to see, and see it anywhere. Fujifilm Computed Radiography (FCR) that makes the best use of Fujifilm s unique image processing technology has become even more convenient. In addition

More information

General Construction & Operation of Oscilloscopes

General Construction & Operation of Oscilloscopes Science 14 Lab 2: The Oscilloscope Introduction General Construction & Operation of Oscilloscopes An oscilloscope is a widely used device which uses a beam of high speed electrons (on the order of 10 7

More information

4 Use the adjustable Focus meter tool to take the subjectivity out of focusing the image, to get the best possible image

4 Use the adjustable Focus meter tool to take the subjectivity out of focusing the image, to get the best possible image Standard Edition VISIONx INC. www.visionxinc.com Real-Time Full Color Image Acquisition 4 Full support for NTSC and PAL cameras with Composite, Y/C (i.e. S-Video) and RGB video signal formats 4 Image display

More information

Product Information PI

Product Information PI Product Information PI TOSHIBA X-RAY TUBE D-045 Stationary Anode X-ray Tube Especially designed for dental radiography unit. This tube has focus 0.4, and is available for maximum tube voltage 70 kv. Installed

More information