Indoor Contact Input Photosensor

Size: px
Start display at page:

Download "Indoor Contact Input Photosensor"

Transcription

1 General Information Indoor Contact Input Photosensor INSTALLATION SHEET Model# PPS-4 The Indoor Contact Input Photosensor (PPS-4) can be used with any Greengate lighting controller and may also be used in conjunction with Greengate Switchpacks and BAS version motion sensors for daylight harvesting. The operating range of the photosensor is 1 to 1400 footcandles. It should be placed indoors only and works optimally within the temperature range of 50º to 104º F. The photosensor is powered directly from the Greengate Lighting Controller 24VDC peripheral power terminal or from a Greengate Switchpack. The photosensor has an automatic deadband feature. From the user selected ON threshold which can be set at points between 1-850FC, the photosensor allows a 25%, 50%, 75% or 100% deadband. In addition to the deadband, the photosensor allows an OFF time delay to prevent nuisance cycling. The photosensor has been provided with a threaded mounting post and washer and lock nut to allow connection through a ceiling tile. The mounting post may be removed by squeezing it near the base of the PPS-4. This allows it to be mounted using the two screw holes under the cover. Use two #6 pan head screws that are appropriately length for the mounting location. This type of mounting may be used for sheetrock locations. Window Application When used in a window application, the PPS-4 should be located within 12 feet of the window and away from any direct light from controlled fixtures. Ideally, locating the photosensor between the window and first row of fixtures is recommended. Rotate the PPS-4 so that the light sensor is nearest the window. Getting Started 1. Do not discard these installation instructions. Please keep for future reference and operation information. 2. It is recommended that all low-voltage wiring be done with power removed to the logic board to protect components from potential shorts during the wiring process. 3. Use only as intended and at the listed voltage. 4. All installation and service must be performed by qualified personnel or service technicians. 5. Install in accordance with the National Electrical Code and any other codes which may apply. 6. Installation and wiring information contained in this document is based on industry-accepted standards and practices. If conflicts exist between these instructions and any applicable codes or ordinances, please contact Greengate before proceeding with the installation. 7. High voltage is present inside the lighting enclosure. Use extreme caution when performing maintenance on this equipment. 8. Document all wiring and device terminations and locations so that devices can be properly configured and programmed for operation. Skylight Application There are two options for mounting a sensor that will be looking at contributed light from a skylight. It is important that the sensor be mounted such that it is not looking at direct sunlight as this will cause the sensor to exceed the maximum of its range. To prevent this, locate the sensor either on the South wall of the skylight well looking North (sensor should be rotated so that the sensor s eye is at the top) or mount on the ceiling next to the skylight looking down at the floor (sensor should be rotated so that the sensor s eye is closest to the skylight well). Mounting Detail When performing daylight harvesting, choice of the mounting location for the photosensor is the key to success. It is important to choose a location that is representative of the day-lighting in the area being controlled. Shadows should also be taken into account as they will affect the day-lighting application. Cooper Controls 203 Cooper Circle, Peachtree, GA Wiring Detail

2 All low-voltage wiring is Class 2 wiring. All low-voltage wiring must be run in separate conduit from line-voltage wiring. Failure to separate high-voltage from low-voltage wiring may cause interference with lighting controller or motion sensor function. Low-voltage wiring must enter the Greengate lighting controller enclosure through the low-voltage section of the enclosure. Cabling should be 18 AWG twisted, three-conductor, unshielded cable. Maximum length for dry contact closure device wiring is 1000 feet. Wiring the PPS-4 to a Lighting Controller The PPS-4 photosensor wires to the low-voltage switch input channels on the lighting controller s logic board. 1. Connect the Blue wire to the ON of the input channel. 2. Connect the Red wire to the +24VDC of the input channel. 3. Connect the Black wire to the Ground (GND) connection on the peripheral power terminal. Figure-3: LiteKeeper 4 Connection Figure-1: LiteKeeper 16/32 Connection Figure-4: ControlKeeper T Connection Figure-2: LiteKeeper 8 Connection Page 2 Figure-5: ControlKeeper 4 Connection

3 Wiring the PPS-4 to a Greengate BAS Sensor Alternatively, the PPS-4 photosensor may wire directly to a Greengate Switchpack and BAS sensor to provide daylight harvesting capability in a motion sensor application. In this configuration, the BAS contacts are used for the photosensor wiring. When the photosensor sees enough light, the lighting will turn off and remain off regardless of motion sensor activity. When the light level is lower, the photosensor will revert lighting back to motion control. Figure-6: ControlKeeper 4A Connection Adjusting the PPS-4 Figure-7: ControlKeeper 2 Connection The PPS-4 has an onboard LCD display to allow for easy user adjustment. The display will power down after a 10 minute period of inactivity. To activate the screen again, press either the Menu or Select button and the display will illuminate. The Menu button will allow you to cycle through the main menu items. The Select button is used to view options within the menus, select options and save changes. Wiring the PPS-4 to a Greengate Switchpack The PPS-4 photosensor may alternatively wire directly to a Greengate Switchpack and optional wall switch. In this configuration, the wall switch must be a two-wire momentary switch. The wall switch may be used to override the photosensor s OFF - command for 1 hour before the sensor reverts to normal operation. There are three main settings that will need adjustment for the photosensor to operate properly. These include the ON threshold, the OFF threshold and the Time Delay setting. When the light level drops below the ON threshold for 20 seconds, the photosensor issues an ON command. When the light level goes above the OFF threshold, the sensor will wait for the period of time defined in the Time Delay settings and then turn off the lights if the light level is still above threshold. Page 3

4 Step 1: Verify Control Overriding the Sensor If the PPS-4 is wired to a lighting control panel, it is recommended that the sensor be programmed into the lighting controller prior to proceeding with these steps to allow for test of functionality. Remember to program the sensor as a maintained contact. 1. Pop the cover off of the photosensor to expose the Menu and Select buttons and display. 2. If the display is not illuminated, press the menu button. The display will illuminate. 3. Press the menu button until the CTRL screen is displayed. 4. Press the Select button to toggle the override between ON and OFF. The display will update with the overridden status. Verify that the lighting responds. 5. The override will remain active until the menu button is used to cycle back through the menu options or will time out automatically in 10 minutes. Step 2: Setting the ON Threshold It is best to set the PPS-4 switching thresholds when the space is at the light level that the lights should turn ON. The default setting is 7.5FC. 1. Make certain that the lighting is at the level in the space where you want the lighting to turn on. 2. Press the menu button until the display is at the CTRL 3. Press the Select button until the display reads OFF and the lights are OFF. 4. Press and hold the select button for 2 seconds until MEM 5. Press the Menu button until the FC Reading Menu is sensor. Make note of the current light level. This value will be the desired FC target value for the ON threshold. 6. Press the menu button until the ON Threshold Menu is displayed (ON XX). 7. Press the Select button until the closest FC value to the noted reading is displayed. 8. When the desired FC threshold is displayed, press and hold down the select button for about 2 seconds until MEM Step 3: Setting the OFF Threshold The PPS-4 will calculate a 25%, 50%, 75% and 100% deadband value for the OFF based on the ON threshold being used. The default setting is 50% deadband. It is important to have adequate separation between the ON and OFF thresholds to prevent cycling due to thresholds being crossed when lighting is switched on and off. To prevent this from occurring: 1. Set up the ON threshold. 2. Press the menu button until the display is at the CTRL 3. Press the Select button until the display reads CTRL ON and the lights are ON. 4. Press and hold the select button for 2 seconds until MEM 5. Press the Menu button until the FC Reading Menu is sensor. Make note of the current light level. 6. Press the menu button until the display is at the CTRL 7. Press the Select button until the display reads CTRL OFF and the lights are OFF. 8. Press and hold the select button for 2 seconds until MEM 9. Press the Menu button until the FC Reading Menu is sensor. Make note of the current light level. 10. Take the initial reading with the lights on and subtract the figure from the reading with the lights off. This is the minimum deadband in FC that needs to be maintained to prevent the lights from cycling. 11. Press the Menu button until the ON Threshold Menu is displayed (ON XX). 12. Press the Select button to cycle through the available OFF thresholds and select the appropriate setting. 13. Press and hold down the Select button for approx. 2 seconds until MEM appears at the top of the sensor s display window. ON Value OFF Deadband Value FC 25% 50% 75% 100% NA NA NA NA NA NA NA NA NA NA NA NA Page 4

5 Step 3 Setting the Time Delay The time delay setting determines how long the light level must be above the OFF threshold before the lighting turns OFF. The default setting is 10 minutes. To change this setting: 1. Press the menu button until the display shows the Time Delay Menu (TIME #M). This is the current time delay setting. 2. Press the Select button until the desired choice is shown. Choices include 3 minutes, 10 minutes, 20 minutes and 30 minutes. 3. When the desired number of minutes is displayed, press and hold down the select button for about 2 seconds until MEM Additional PPS-4 Information Testing the Sensor It is possible to place the sensor in test mode. In this mode, the sensor will immediately switch lighting on or off upon the cross of the on or off thresholds. If a sensor is left in test mode, it will automatically revert to normal operation after 30 minutes. 1. Press the menu button until the display reads SETUP. 2. Press the select button once. The display will read TEST. 3. Press the select button again. The display will read TEST ON and the sensor LED will flash. The sensor is now in test mode. 4. Once test is complete, process steps 1-3 again to turn off test mode. It is also possible to test the sensor for functionality by overriding the sensor on and off. Refer to the Step 1: Verify Control Overriding the Sensor section for details on overriding the sensor. Resetting the Sensor It is possible to reset the sensor to factory defaults. Press and hold both the Menu and the Setup buttons at the same time. The display will default to the main screen and factory defaults will be restored. Additional functions of the photosensor are not used in the Greengate application. LED Functions LED Status OFF ON solid Green Green flashing rapidly (once per second) Green flashing slowly (once every four seconds) Description The lights are commanded ON by the PPS-4 The lights are commanded OFF by the PPS-4 The PPS-4 is in test mode The PPS-4 is being overridden either by the CTRL override menu or by an external two wire momentary wall switch. All products manufactured by Cooper Controls and identified with the Greengate brand are warranted to be free from defects in material and workmanship and shall conform to and perform in accordance with Seller s written specifications for a period of : Five (5) years from date of shipment for all occupancy sensors. Three (3) years from date of factory invoice for our hardware and software on Lighting Control Panels. We warranty all our standard relays for a period of 10 years from date of factory invoice. We guarantee the performance of our system to specifications of your money back. This warranty will be limited to the repair or replacement, at Seller s discretion, of any such goods found to be defective, upon their authorized return to Seller. This limited warranty does not apply if the goods have been damaged by accident, abuse, misuse, modification or misapplication, by damage during shipment or by improper service. There are no warranties, which extend beyond the hereinabove-limited warranty, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS. No employee, agent, dealer, or other person is authorized to give any warranties on behalf of the Seller or to assume for the Seller any other liability in connection with any of its goods except in writing and signed by the Seller. The Seller makes no representation that the goods comply with any present or future federal, state or local regulation or ordinance. Compliance is the Buyer s responsibility. The use of the Seller s goods should be in accordance with the provision of the National Electrical Code, UL and/or other industry or military standards that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous. Cooper Controls 203 Cooper Circle, Peachtree, GA P/N

Starbox. Installation guide

Starbox. Installation guide Starbox Installation guide Introduction Welcome The Starbox is a wiring centre that allows ican networks to be wired in a star topology (as an alternative to the standard daisy-chain topology). The Starbox

More information

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION Installation and Operation Manual MSI Multi-Sensor Interface Hub Interface Module for all Sensors Network and Wireless CAUTION This equipment complies with the limits for a Class B digital device, pursuant

More information

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version MR9 WARRANTY Steffes Corporation ( Steffes ) warrants that the Steffes Power Line Carrier Mini Receiver is free from defects in materials and workmanship under normal use and service. Steffes obligation

More information

with Light Level, Isolated Relay and Manual On features

with Light Level, Isolated Relay and Manual On features DT-200 version 3 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On features SPECIFICATIONS Voltage... 18-28VDC/VAC Current Consumption... 25mA Power Supply...WattStopper

More information

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K O P E R A T I N G I N S T R U C T I O N S WEL-200 TM W I R E L E S S E D G E L I N K 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com

More information

DLC-PDC PHOTODIODE CONTROLLER

DLC-PDC PHOTODIODE CONTROLLER DLC-PDC PHOTODIODE CONTROLLER INSTALLATION AND OPERATION INSTRUCTIONS 203 Cooper Circle, Peachtree City, GA 30269 Customer Service: Telephone: (800) 553-3879 Fax: (800) 954-7016 DLC-PDC Rev. 2 TABLE of

More information

MAS SENSORS INSTALLATION AND MAINTENANCE MANUAL (IMM)

MAS SENSORS INSTALLATION AND MAINTENANCE MANUAL (IMM) MAS SENSORS INSTALLATION AND 205_MAS_R.1_6-14-10 A Division of PLCMultipoint GENERAL INTRODUCTION 1. Please read these instructions carefully to prevent any possible injury or equipment damage. 2. Installer

More information

CES SENSORS INSTALLATION AND MAINTENANCE MANUAL (IMM)

CES SENSORS INSTALLATION AND MAINTENANCE MANUAL (IMM) CES SENSORS INSTALLATION AND 205_CES_R.1_7-8-10 A Division of PLCMultipoint GENERAL INTRODUCTION 1. Please read these instructions carefully to prevent any possible injury or equipment damage. 2. Installer

More information

LPU-2127 User Manual

LPU-2127 User Manual LPU-2127 User Manual Doc #9004169 Rev A1, 04/15 Table of Contents Introduction... iii Warranty and Warranty Restrictions... iv Chapter 1: Specifications and Options... 1 Dimensions...1 Specifications...

More information

C-Bus 8 Channel Low Voltage Relay

C-Bus 8 Channel Low Voltage Relay SLC5108RELVP Instruction Bulletin Retain for future use. 63249-420-325A1 Instruction Bulletin 07/2009 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to

More information

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM Item #1001 510 115 Model DIY-600PS USE AND CARE GUIDE TRANSFORMER Questions, problems, missing parts? Before returning to the store, call HamptonBay Customer Service 8 a.m. - 7 p.m., EST, Monday Friday,

More information

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide www.i2systems.com i2systems is a registered trademark of Integrated Illumination Systems, Inc. LightLink is a trademark of Integrated Illumination Systems, Inc. 2018 Integrated Illumination Systems, Inc.

More information

Wireless Transceiver (TRV)

Wireless Transceiver (TRV) Installation and Operation Manual Wireless Transceiver (TRV) For Platinum Controls with Communication WARNING This equipment complies with the limits for a Class B digital device, pursuant to Part 15 of

More information

v3 360 Passive Infrared Line Voltage Occupancy Sensor

v3 360 Passive Infrared Line Voltage Occupancy Sensor SPECIFICATIONS CI-355 v3 360 Passive Infrared Line Voltage Occupancy Sensor with Light Level feature Voltages... 120//230/277/347VAC, 50/60Hz Load Ratings @120VAC...0-800W Ballast/Tungsten/LED @230VAC

More information

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

Instruction Sheet REB SERIES. Rotating Sliding Base REB18 Instruction Sheet REB SERIES Rotating Sliding Base REB14 REB18 THANK YOU Thank you for purchasing the REB Series Rotating Sliding Base. Please read these instructions thoroughly before installing this

More information

Using the USB Output Port to Charge a Device

Using the USB Output Port to Charge a Device Table of Contents ----------------------------------- 2 Features ----------------------------------------------- 3 Controls and Functions ---------------------------------- 4 ER210 Power Sources -----------------------------------

More information

LC8 & LC8-15. Single Level Lighting Controller INSTALLATION AND MAINTENANCE MANUAL (IMM) 205_LC8_R4

LC8 & LC8-15. Single Level Lighting Controller INSTALLATION AND MAINTENANCE MANUAL (IMM) 205_LC8_R4 Single Level Lighting Controller INSTALLATION AND MAINTENANCE MANUAL (IMM) 205_LC8_R4 TABLE of CONTENTS 1 INTRODUCTON...3 1.1 GENERAL...3 1.2 OVERVIEW...3 2 INSTALLATION...4 2.1 POWER CONNECTIONS...4 2.2

More information

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL Introduction Thank you for choosing ZRP-100 Z-Wave Repeater product! ZRP-100 is a Z-Wave repeater with best RF performance to repeat Z-Wave

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS K4460V2 3/01 6150RFPL2 Keypad/Transceiver About the 6150RFPL2 The 6150RFPL2 is a combination unit that contains: A 6150PL2 Fixed Addressable Keypad A 5800TM Transmitter Module

More information

User s Guide. Model MA A AC Mini Clamp-on Meter

User s Guide. Model MA A AC Mini Clamp-on Meter User s Guide Model MA150 200A AC Mini Clamp-on Meter Introduction Congratulations on your purchase of Extech s MA150 AC Mini Clamp Meter. This meter is shipped fully tested and calibrated and, with proper

More information

MODEL 8080PR3 Released on 11th Mar 2013

MODEL 8080PR3  Released on 11th Mar 2013 MODEL 8080R3 Released on 11 th Mar 2013 DUAL CHANNEL TEMERATURE INDICATOR WITH ALARMS 8080R3 DESCRITION The IME 8080R3 is a micro-controller based Digital Dual-channel Indicator with two relay outputs

More information

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL Table of Contents -------------------------------------- 2 Features ----------------------------------------------- 3 Controls and

More information

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions WARRANTY ADDENDUM TROUBLESHOOTING INSTALLATION OVERVIEW M2 Antenna Systems, Inc. Model No: S3 Sequencer Operating Instructions PLEASE READ BEFORE USE AND SAVE M2 Antenna Systems, Inc. 4402 N. Selland Ave.

More information

INSTALLATION AND SETUP GUIDE

INSTALLATION AND SETUP GUIDE INSTALLATION AND SETUP GUIDE K4460V3 4/06 Rev A 6150RFPL2 Keypad/Transceiver GENERAL INFORMATION The 6150RFPL2 Keypad/Transceiver is a combination unit incorporating a normally-open relay output and the

More information

OPERATOR S MANUAL Model 58B Prefeed / Dereeler

OPERATOR S MANUAL Model 58B Prefeed / Dereeler 110 Fairgrounds Drive P.O. Box 188 Manlius, NY 13104-0188 USA 315.682.9176 FAX: 315.682.9160 OPERATOR S MANUAL Model 58B Prefeed / Dereeler PRODUCTION WIRE PROCESSING EQUIPMENT Website: www.carpentermfg.com

More information

Programmable K-Factor Scaler B and Programming Software Kit B

Programmable K-Factor Scaler B and Programming Software Kit B Programmable K-Factor Scaler B220-885 and Programming Software Kit B220-900 INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770

More information

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions F5140 and Programming Kit F5141 8635 Washington Avenue Racine, WI 53406 USA Tel: 800-433-5263 or 262-639-6770 Fax: 800-245-3569 or 262-639-2267 E-Mail: flo-techsales@racinefed.com www.flo-tech.com TABLE

More information

Taurus CP-300 Single Pump

Taurus CP-300 Single Pump Taurus CP-300 Single Pump The Taurus CP-300 dispenses liquid chemicals with a high degree of accuracy and repeatability. A separately wired remote provides a convenient way to start the cycle. Simple mounting,

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology Instruction Bulletin 63249-420-283A4 08/2009 Wall Mount Occupancy Sensor SLSWPS1500, SLSWUS1500, SLSWDS1500 INTRODUCTION Wall Mounted Occupancy Sensors are Class 2 devices ideal for use in business or

More information

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 500 Humbolt Street Los Alamitos, CA 9. If for

More information

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

IRRIGATION 810-T PLUS TRANSMITTER GUIDE IRRIGATION 810-T PLUS TRANSMITTER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 BASIC WIRING INSTRUCTIONS 4 HOW TO CONTROL AND SHARE MULTIPLE WELLS 5 TRANSMITTER FUNCTION SWITCH SETTINGS 5 LED INDICATORS 5 OPERATING

More information

OWNER S MANUAL DANGER

OWNER S MANUAL DANGER OWNER S MANUAL The actual product you have received may differ slightly from the illustration. DANGER To ensure safe operation of the product, be sure to read this Operation Manual before use. Keep this

More information

User Manual. ProRF Encoder Transmitter & Receiver

User Manual. ProRF Encoder Transmitter & Receiver User Manual ProRF Encoder Transmitter & Receiver WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original

More information

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806 Series 500 Analog Transmitters by Data Industrial Data Industrial Owner s Manual Data Industrial 2/95 PN 72806 Table of Contents Introduction... 1 4-20 ma Loop Supply Requirements... 2 Installation...

More information

X80 Activator. User's Manual. Version 1.1.

X80 Activator. User's Manual. Version 1.1. X80 Activator User's Manual Version 1.1 www.buckeyecam.com Table of Contents 1. Warnings... 3 2. Overview... 4 3. Getting Started... 5 4. Using the Activate Button... 7 5. Wiring... 8 6. Specifications...

More information

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE OPERATION & SERVICE MANUAL FOR FC 100 SERIES AC POWER SOURCE FC 110 AC POWER SOURCE VERSION 1.3, April 2001. copyright reserved. DWG No. FC00001 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 1.1 GENERAL...

More information

Pen Multimeter. Model

Pen Multimeter. Model Pen Multimeter Model 381626 CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. This instrument is a 3200 count pen style digital

More information

ELECTRO-MECH SCOREBOARD CO. SL-230 / 330 RF MODEM INSTALLATION MANUAL

ELECTRO-MECH SCOREBOARD CO. SL-230 / 330 RF MODEM INSTALLATION MANUAL ELECTRO-MECH SCOREBOARD CO. SL-230 / 330 RF MODEM INSTALLATION MANUAL Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that this product will give many years

More information

Installation Instructions

Installation Instructions SPECIFICATIONS WS-200 Automatic PIR Wall Switch Voltages...........................120 or 277VAC, 60Hz Requirements @ 120VAC, 60Hz........0-800W ballast & tungsten @ 277VAC, 60Hz.................0-1200W

More information

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR Product Overview The is a fixture-integrated dimming photosensor. It provides a continuous dimming signal to a 0-10 VDC dimming ballast, based on daylight

More information

Single-zone Daylighting Control Sequences of Operation. Topic: DLM Operation with LMLS-400 Photosensor, v2.xx Issue: # TB185 Date: March 10, 2012

Single-zone Daylighting Control Sequences of Operation. Topic: DLM Operation with LMLS-400 Photosensor, v2.xx Issue: # TB185 Date: March 10, 2012 Understanding the capabilities of Digital Lighting Management (DLM) photosensors, and how to configure the sensors for the desired control strategy is one key to successful daylighting controls projects.

More information

MorningLinc INSTEON Morning Industry RF Doorknob/Deadbolt Controller

MorningLinc INSTEON Morning Industry RF Doorknob/Deadbolt Controller MorningLinc INSTEON Morning Industry RF Doorknob/Deadbolt Controller Model : 2458A1 MorningLinc Owner s Manual MorningLinc Owner s Manual TABLE OF CONTENTS ABOUT MORNINGLINC... 2 Key MorningLinc Features...

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS K4456V1 8/00 FA260RF Keypad/Transceiver About the FA260RF The FA260RF is a combination unit that contains: A FA260KP Fixed Addressable Keypad A 5800TM Transmitter Module A 5881M

More information

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers DA6002D-DA10004D INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers Preparation Please read entire manual before installation. Due to the technical nature of amplifiers, it is highly recommended that

More information

2015 RIGOL TECHNOLOGIES, INC.

2015 RIGOL TECHNOLOGIES, INC. Service Guide DG000 Series Dual-channel Function/Arbitrary Waveform Generator Oct. 205 TECHNOLOGIES, INC. Guaranty and Declaration Copyright 203 TECHNOLOGIES, INC. All Rights Reserved. Trademark Information

More information

SENSORS INSTALLATION AND MAINTENANCE MANUAL (IMM)

SENSORS INSTALLATION AND MAINTENANCE MANUAL (IMM) PD SENSORS INSTALLATION AND 205_PD_R.1_6-14-10 A Division of PLCMultipoint GENERAL INTRODUCTION 1. Please read these instructions carefully to prevent any possible injury or equipment damage. 2. Installer

More information

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32 User's Guide Wireless AC Circuit Identifier Models RT30 and RT32 Introduction Congratulations on your purchase of Extech s Model RT30 (914Mhz) or RT32 (869MHz) Wireless AC Circuit Identifier. The detector

More information

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C FA401 Single Transmitter / Single Output Receiver FA401R Single Transmitter / Single Relay Output Receiver Frequency Agile 900MHz Installation Instructions 02305C Note: The FA401 is intended to be installed

More information

ASSEMBLY AND INSTALLATION INSTRUCTIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS T0412 / T0413 ASSEMBLY AND INSTALLATION INSTRUCTIONS WARNING: NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. READ AND SAVE THESE INSTRUCTIONS. Hardware

More information

NCS-C150 INSTRUCTION MANUAL Rev D. Collcomm Inc. d.b.a. NCS. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

NCS-C150 INSTRUCTION MANUAL Rev D. Collcomm Inc. d.b.a. NCS. Shipping Address 2310 Pendley Road Cumming, Georgia 30041 NCS-C150 INSTRUCTION MANUAL Rev D Collcomm Inc. d.b.a. NCS Shipping Address 2310 Pendley Road Cumming, Georgia 30041 Mailing Address 1595 Peachtree Parkway Suite 204-123 Cumming, Georgia 30041 Toll Free

More information

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16 QuadroMAX LED Outdoor Lighting Fixtures Installation Manual QM Series REV: 3/22/16 BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING Risk of fire or electric shock. Luminaire wiring

More information

f i r e - p a r t s. c o m

f i r e - p a r t s. c o m Model: CON 1001-1 INSTALLATION AND OPERATING INSTRUCTIONS SINGLE-FUNCTION WIRELESS REMOTE CONTROL SYSTEM FOR OPERATING VALVES WITH ON/OFF LATCHING SOLENOIDS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION

More information

4Post and 2Post Universal Shelf System for 19 Racks

4Post and 2Post Universal Shelf System for 19 Racks Patent(s) Pending 4Post and 2Post Universal Shelf System for 19 Racks Installation Instructions Kit P/N: 108-4013 108-4261 Kit Contents (1) Shelf (2) Rear Brackets Front Hardware Kit (4) 8-32 x.375 Flat

More information

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev. , Inc. Eight Channel DMX Pack (includes information for -S) S S S S 4 8 USER'S MANUAL -UM User's Manual - Page GENERAL DESCRIPTION The is an 8-channel DMX- compatible dimmer pack. It contains three printed

More information

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL Table of Contents -------------------------------------- 2 Features ----------------------------------------------- 3 Controls and

More information

VAN STORAGE SOLUTIONS FOR THE WAY YOU WORK

VAN STORAGE SOLUTIONS FOR THE WAY YOU WORK WWW.WEATHERGUARD.COM VAN STORAGE SOLUTIONS FOR THE WAY YOU WORK Weather Guard / KNAACK 420 E. Terra Cotta Ave. Crystal Lake, IL 60014 USA 800-456-7865 (Toll Free) 800-334-2981 (Fax) Knaack.OrderEntry@wernerco,.com

More information

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 Phone: (905) 564-0801 Fax: (905) 564-0806 www.telecor.com E:\T2-108\T2-M108-ABC\T2-M108-B.doc/AD

More information

LT3000 ULTRASONIC LEVEL TRANSMITTER

LT3000 ULTRASONIC LEVEL TRANSMITTER LT3000 ULTRASONIC LEVEL TRANSMITTER Owner s Manual Specifications Installation Calibration Troubleshooting Warranty Drawings Distributed By: iprocessmart.com 14262 Doolittle Drive San Leandro, CA 94577

More information

Product Manual. Getting Started with Roadie 2.

Product Manual. Getting Started with Roadie 2. MOL NUMBER RD200 Product Manual Getting Started with Roadie 2. This manual is a quick start guide for Roadie 2. Please read the following instructions and conditions before using Roadie 2. For a more comprehensive

More information

POWER TRACE TM TASCO, INC.

POWER TRACE TM TASCO, INC. POWER TRACE TM Instruction Manual PTL610 TASCO, INC. HOW YOUR POWER TRACE TM OPERATES The Power Trace TM is composed of two primary components: the Receiver and the Transmitter. When the Transmitter is

More information

Field Hub Installation Guide. P/N Rev. C 05/15

Field Hub Installation Guide. P/N Rev. C 05/15 Field Hub Installation Guide P/N016-0171-380 Rev. C 05/15 E21714 Copyright 2015 Disclaimer While every effort has been made to ensure the accuracy of this document, Raven Industries assumes no responsibility

More information

CDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection.

CDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection. Carbon Dioxide - User Manual 1 Intended Use 2 Functional Description 2.1 Control Mode 2.2 Sensor 3 Installation 3.1 Mounting instructions 3.2 Installation 4 Electrical Connection 4.1 Instruction 5 Commissioning

More information

Ultrasonic Level Transmitter Model LU20 Owner s Manual

Ultrasonic Level Transmitter Model LU20 Owner s Manual Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 15 Humbolt Street Los Alamitos, CA 972. If for

More information

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers DA560D COMPACT SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers Preparation Please read entire manual before installation. Due to the technical nature of amplifiers, it is highly recommended

More information

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers XPR522 XPR540 XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers Preparation Please read entire manual before installation. Due to the technical nature of amplifiers, it is highly recommended

More information

NCS-C150 INSTRUCTION MANUAL Rev A. Collcomm Inc. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

NCS-C150 INSTRUCTION MANUAL Rev A. Collcomm Inc. Shipping Address 2310 Pendley Road Cumming, Georgia 30041 NCS-C150 INSTRUCTION MANUAL Rev A Collcomm Inc. d.b.a. NCS Shipping Address 2310 Pendley Road Cumming, Georgia 30041 Mailing Address 1595 Peachtree Parkway Suite 204-123 Cumming, Georgia 30041 Toll Free

More information

RUSH G1 MECHANICAL KEYBOARD PRODUCT MANUAL V.14

RUSH G1 MECHANICAL KEYBOARD PRODUCT MANUAL V.14 RUSH G1 MECHANICAL KEYBOARD V.14 SOFTWARE INSTALLATION DOWNLOAD SOFTWARE INSTALLER From: http://download.fnatic.com RUN THE INSTALLER ACCEPT POP UPS If you are prompted by any pop ups during the installation,

More information

PreView Plus Monitor. PVP710 Setup Guide.

PreView Plus Monitor. PVP710 Setup Guide. PreView Plus Monitor PVP710 Setup Guide www.preco.com TRADEMARKS The names of actual companies and products mentioned herein may be the trademarks of their respective owners. Any rights not expressly

More information

Planishing hammer stand For use with SKU Planishing hammer

Planishing hammer stand For use with SKU Planishing hammer Planishing hammer stand For use with SKU 94847 Planishing hammer Model 96300 Assembly And Operation Instructions Please Note: Planishing Hammer not included with Stand. Due to continuing improvements,

More information

Installation Instructions

Installation Instructions TECH SUPPORT The Watt Stopper, Inc. 2800 De La Cruz Blvd. Santa Clara, CA 95050, USA Tel: 1(800)879-8585 1(972)578-1699 Fax: 1(972)422-1311 www.wattstopper.com Outdoor 180 & 270 PIR Motion s Model#s: EW-100-120

More information

Earth Fault Indicator EFI-BLZ-50 User Manual

Earth Fault Indicator EFI-BLZ-50 User Manual Earth Fault Indicator EFI-BLZ-50 User Manual CONTENTS SAFETY NOTICE.................................................................................... 3 1 OVERVIEW......................................................................................

More information

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein. 15 Planer Stand Model 96316 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo,

More information

INSTRUCTION MANUAL INF Fax: (503)

INSTRUCTION MANUAL INF Fax: (503) INSTRUCTION MANUAL INF151 1-800-547-5740 Fax: (503) 643-6322 www.ueiautomotive.com email: info@ueitest.com Introduction Congratulations on your purchase of the INF151 infrared thermometer. Like all UEi

More information

Angular Rate Sensor. Owner's Manual

Angular Rate Sensor. Owner's Manual Angular Rate Sensor Owner's Manual Part Number: ARS-C132-1A WATSON INDUSTRIES, INC. 3041 MELBY ROAD EAU CLAIRE, WI 54703 Phone: (715) 839-0628 FAX: (715) 839-8248 email: support@watson-gyro.com 1 Table

More information

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 912 Power Amplifier. P/N: Rev 2

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 912 Power Amplifier. P/N: Rev 2 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 912 Power Amplifier P/N: 2900-000684 Rev 2 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 3 Overview 3 3.1 Defining the 912

More information

WS-7220U-IT 915 MHz Wireless Weather Station. Instruction Manual

WS-7220U-IT 915 MHz Wireless Weather Station. Instruction Manual WS-7220U-IT 915 MHz Wireless Weather Station Instruction Manual 1 TABLE OF CONTENTS Introduction..3 Inventory of Contents 4 Quick Set Up 4 Detailed Set Up 4-5 Battery Installation....4-5 12 or 24 Hour

More information

Single Arm Pole Mount. Installation Manual Edition v1.01. For models: UNI-SA/14 UNI-SA/21.5 UNI-SA/26 UNI-SA01-MAN

Single Arm Pole Mount. Installation Manual Edition v1.01. For models: UNI-SA/14 UNI-SA/21.5 UNI-SA/26 UNI-SA01-MAN Pole Mount Installation Manual 2016 Edition v1.01 For models: UNI-SA/14 UNI-SA/21.5 UNI-SA/26 UNI-SA01-MAN Table of Contents 1 1 2 3 4 5 5 Introduction Customer Support Project Essentials Assembly: Steps

More information

Mist. now you know. Clock Radio with Weather Forecast. Quick Start Guide and User Manual

Mist. now you know. Clock Radio with Weather Forecast. Quick Start Guide and User Manual Mist Clock Radio with Weather Forecast Quick Start Guide and User Manual now you know. Contents 2 Welcome to Ambient Devices! 3 Quick Start Guide 5 Getting to know your Mist Clock Radio 8 Using your Mist

More information

SA-027HQ 365-Day Annual Timer

SA-027HQ 365-Day Annual Timer SA-027HQ 365-Day Annual Timer Manual Two N.O. or N.C. Form C relays, 10A@14VDC Each relay can be programmed for 50 events, for a total of 100 individual programmable events 10 Programmable holidays The

More information

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression WORLD-BEAM QS8AFF00 Sensors with Foreground Suppression Datasheet Compact sensors featuring extended range and foreground suppression mode Exceptional optical performance; up to 00 mm sensing range in

More information

P/N: TMPRO3PLUS SERVICE AND WARRANTY

P/N: TMPRO3PLUS SERVICE AND WARRANTY SERVICE AND WARRANTY Should your unit ever require service, please do not return the product to your dealer. Please call the number below for special instructions on shipping and handling. Please call

More information

LASER ENHANCED REVOLVER GRIP OWNER S MANUAL RED LASER GREEN LASER

LASER ENHANCED REVOLVER GRIP OWNER S MANUAL RED LASER GREEN LASER LASER ENHANCED RED LASER GREEN LASER REVOLVER GRIP OWNER S MANUAL LASER ENHANCED GRIP Installation Instructions Caution... 3 Safety Labels... 4 Installation...5-7 Programming...8-10 Batteries (Red Laser)...

More information

4.Ebz!Gpsfdbtufs G U I D E n catio Lo

4.Ebz!Gpsfdbtufs G U I D E n catio Lo GUIDE Location Contents Ambient Devices TM, the Ambient logo, Ambient Information Network TM and Ambient 3-Day Forecasters TM are trademarks or registered trademarks of Ambient Devices, Inc. All rights

More information

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers DA604D DA954D DA501D DA801D COMPACT SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers Preparation Please read entire manual before installation. Due to the technical nature of amplifiers, it

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail : globalw@globalw.com PC320 Process Controller

More information

Dialight Daylight Harvesting Sensor User Guide

Dialight Daylight Harvesting Sensor User Guide Daylight Harvesting Sensor Dialight Daylight Harvesting Sensor User Guide Dialight Catalog Number: DLHU124UG2 1 Safety Instructions Dialight Daylight Harvester Sensor (DLH) User Guide READ AND FOLLOW ALL

More information

CURATED CARTESIAN VANITY

CURATED CARTESIAN VANITY CURATED CARTESIAN VANITY CONTENT Prep the wall - 3 Frame installation - 5 Attaching the side kits - 7 Installing any optional vanity accessories - 7 Sink assembly - 8 Insert the drawer - 10 Attaching glass

More information

OWNER S MANUAL DANGER

OWNER S MANUAL DANGER OWNER S MANUAL The actual product you have received may differ slightly from the illustration. DANGER To ensure safe operation of the product, be sure to read this Operation Manual before use. Keep this

More information

Grid Radar Installation Manual

Grid Radar Installation Manual Grid Radar Installation Manual MODELS GN-RD-001 120V Single Phase / Wye, 240V Single Phase, with Neutral GN-RD-002 277V 3-Phase Wye, with Neutral GN-RD-003 480V 3-Phase Delta, no Neutral GN-RD-004 208V

More information

Prospera PL050 byoung Duo Bike User Manual

Prospera PL050 byoung Duo Bike User Manual Prospera PL050 byoung Duo Bike User Manual This user manual provides detailed installation and use information. Please read this manual carefully before installation and operation. Keep this manual for

More information

WORLD-BEAM QS18AF Sensor with Background Suppression

WORLD-BEAM QS18AF Sensor with Background Suppression WORLD-BEAM QS8AF Sensor with Background Suppression Datasheet Compact sensors featuring extended range and background suppression mode Exceptional optical performance; up to 00 mm sensing range in compact

More information

Keychain Radio Remote Control System

Keychain Radio Remote Control System Innovation in Mobility Keychain Radio Remote Control System Operator Manual 04/23/02 95-2002 RICON CORPORATION All Rights Reserved U.S. and foreign patents pending Printed in the United States of America

More information

USER MANUAL Table of Contents

USER MANUAL Table of Contents USER MANUAL Table of Contents Safety Information 3 Specifications 4 Main Power Connection 5 DMX-512 Connection 5 Fixture Level 6 Set Up 6 Operation Options 7 Connection 8 Rigging the Fixture 9 Cleaning

More information

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH INSTRUCTION MANUAL PLEASE READ THIS MANUAL BEFORE OPERATING THIS EQUIPMENT! 116 Willow Road Starkville, MS 39759 USA 662-323-8211 Version 3B Printed in U.S.A.

More information

High/Low Bay Passive Infrared Occupancy Sensor

High/Low Bay Passive Infrared Occupancy Sensor Models Sensors: HBP-111-L7, with IR remote capability HBP-112-L7, no IR capability High/Low Bay Passive Infrared Occupancy Sensor Mounting Modules: HBP-EM1 extender module HBP-SM1 surface mount module

More information

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter English Users Manual Limited Warranty and

More information

Installation Instructions

Installation Instructions WS-250 & WS-250-347 Passive Infrared Wall Switch Occupancy Sensor SPECIFICATIONS WS-250 Voltages...120 or 277VAC, 60Hz Load Requirements @ 120VAC, 60Hz... 0-800W ballast & tungsten, 1/6 hp @ 277VAC, 60Hz...

More information

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Ordering Information. Stepping Relay Unit G9B. Model Number Legend Stepping Relay Unit CSM DS_E_4_1 Ideal for Controlling Pumps and Production Lines with Six or Twelve Stepping Circuits Built-in relays switch 2 A at 250 VAC or 30 VDC. Initialization of stepping with reset

More information

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure QS300480 Rev B 2013 Flowline, Inc. All Rights Reserved Made in USA 10500 Humbolt Street, Los Alamitos, CA

More information