SIREC D MP SIREC D200 SIREC D300 SIREC D400 : MP , CA 01. : E86060-D4001-A110-C (CD-ROM) E86060-D4001-A510-C (DVD) SIREC D

Size: px
Start display at page:

Download "SIREC D MP SIREC D200 SIREC D300 SIREC D400 : MP , CA 01. : E86060-D4001-A110-C (CD-ROM) E86060-D4001-A510-C (DVD) SIREC D"

Transcription

1 SIREC D MP

2 SIREC D MP SIREC D200 SIREC D300 SIREC D400 : MP ,, CA 01. : E86060-D4001-A110-C (CD-ROM) E86060-D4001-A510-C (DVD) Siemens Siemens AG 2007 SIREC D,, - -, - DIN EN ISO 9001.

3 SIREC D200 5 TFT ,, ,. : 5" - (TFT) QVGA (320 x 240 ) 10/100 Ethernet (DHCP), Web, OPC Server Web FTP TCP/IP RS485 Modbus- () USB-. USB., 10,,, USB- Flash- - 21CFR 11 ESS Health Watch ( ) - CE, CSA, UL NEMA 4/IP66 10 (100 ) ( ) (), 3., 4 -.., 3., 3. 3

4 .,.. "",. : ( ) (.) FTP, Modbus TCP/IP ( - ), web - Ethernet ( DHCP) Modbus RTU ( - ) RS485 (). USB- - - ASCII.. Ethernet Ethernet ( DHCP) - (, LAN). Ethernet www. Dynamic Host Configuration Protocol (DHCP) (IP-) DHCP flash ( = 1 ) USB- (flash)., -, -.,.,,,,,. 6 ""..,,. Fuzzy-. ;, -.,.,, - 100:1,. Simple Network Time Protocol (SNTP) ethernet SNTP-,. Web-,, 8 / 4, - ( 4 ) ;. USB- - USB. USB-,, USB-.., ( ), , -.. Microsoft Internet explorer 6. Extended Security System () ESS,, -,. ESS 21CFR 11.

5 CE 73/23/EEC, 89/336/EEC. NEMA 3/IP54. - NEMA 4/IP66. ",. () () USB- 5, - (TFT), QVGA (320 x 240 ) 1 720, %, - 80% 40000, 100% ( %) /² ,,. Ethernet 10/100 base - T RJ45 Modbus/TCP, FTP, Internet, DHCP IP-. RS485 Modbus RTU ( ). RS485 Comms card,,,,. - () , SIN, COS, TAN, Log, (. A1 + A2), -, (A1, P1, D1..) - USB (- ) () -. :, -, ( USB 1.1), -..,, :,,, 20- USB 2 USB 120, 70 (16 ) 400 ( 90 ) (..) 24 USB,,. ( ) FIFO (First In First Out), V AC 250 V AC ( ) 50/60 < V DC / V AC : < 40,, 6032, 3.0 V 10 ( ), 4, ( ). -,, ,,. 2-,. 3-, 4-,

6 (.) (.) C, F, K : ID, ± 29 ppm (± 1 /) 25 C /,. - Ethernet SNTP- / ;., -, ± 100% - - -, -. «-» 1 / 5 / 10 / 20 / 30 / 60 / 120 / 600 / 1200 / 6000 / , - CE ( CE) - : 73/23/EEC,., 89/336/EEC,. - CE. EN I:,, (EN ) NEMA 3/ IP54 (: NEMA 4/IP66) II: (EN ) 2 - EN B - EN EN : 2001, () 3, 6, 9 12,, (),, -, - -, 4% 4% - (50 2%) (..), «-»/ (),, CJC % (16- ) 10,. ± 0.1%, > 1, > (- A - 10 ) () () - 2, 6 ; 200 (5 ), 500 (2 ) 100 (10 ), 200 (5 ), 500 (2 ) -, -, (10 )

7 , ( 20 ) 300 V AC, (-, - ) 50/60 ± 2% (.) - 2 = -120, 5 = = -80, 5 = -25. () - 2 = -120, 5 = -120, 10 = = -85, 5 = -80, 10 = -48 () (. ) (. ) , B E J K R S T L G (W_W26) C (W5, W26) M (NiMo-NiCo) (NNM90) N (Nicosil Nisil) Chromel/Copel C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) P (Platinel) D Pt100 = 0,00385 Pt200 = Pt500 = Pt1000 = , 100, C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F),, /, Fuzzy Fuzzy- / ( x x ) , 100:1 ;, - ; (- ). NEMA 3/IP54. NEMA 4/IP66 ( ) NEMA 3/ IP54 (: NEMA 4/IP66) :. : 55, x 144 x 200 (5.67 x 5.67 x 7.87 ) 80 (3.15 ) ( x ) 138 x 138 (5.43 x 5.43 ). (%RH) () (g) 0.1 (g) (5.3 ) IEC. - 0 C 50 C (32 F F)

8 () (±) 65 () (.) (DC) () AC: < 40 (.), DC: <40 (.), 20 / / 30 (6 ) , 3 A 240 V AC, 3 A 24 V AC/DC, 0.2A 240 V DC (., ) 8 /, 1 A 24 V DC (., ) -. 8 /. / 4, ( 1 4)... / 1. -, - 4, /. 8 / : -. () (C). 2 -, 6. < 500, > 300.,.., : / /.,,,..,.,.,,,, OPC- OPC DA AE 3.0. OPC- 24 OPC,. 1/ / CSA,,. /,,,,, -..,,,,,,, /,,../. SIREC D. -. :. 100% Hi/Lo CJC (. &.), / -.. CSA22.2-No L UL ANSI/UL File # FM 1 2 () Extended Security System (ESS) V DC ± 3 V DC 21 CFR 11. : - (1 10 ) (1 365 ) 50 3, ( 4 12 )

9 /* ( ) ()., Fo Po* C. - ( Z), Y, W V., - Z -,. * Fo/Po /, z T..,,,.,. PCL- USB , 12 SIREC D200. (3 22 )

10 .,,. Factory. Options: -. -,,,,.,,. 4, 100. ( 1) 6,.. :, /, //,,, /,,./. ( 2) / / 4., ; (,..). Fo Po. ( 1) 2.,,,, "", "",, 100%, Hi/Lo CJC (. &.), /.,. 2,. PCL- USB. 3 -.,,, , -. 3.,.., : / /.,,,..,.,., OPC- 8,,, OPC (OLE ). OPC,,,, Microsoft Windows 2 4,.. 12 SIREC D200. (1) ( Extra Pens ),,,,. (2),,,. (, ) :

11 SIREC D200 1) : 144 x 144, / 5 TFT-, Ethernet- () USB- () 50 60, V AC 24 V DC (,,, -,., ) ( / ) ( / ) 4 (240 V) 8, 2 - (240 V) 8 ( 24 V/ ) 70 () / 24 V DC. 200 /USB RS485 ( ) (. ) (ESS) IP54 ( ) ESS ESS IP66 (NEMA 4) ( ) ESS ESS SIREC D ND AD 20 7ND BD 30 7ND CD 40 7ND DD / SIREC D. SIREC D-Manager SIREC D-Server SIREC D-Manager SIREC D-Server. SIREC D ; SIREC D200/D300/D400 ( CD),. SIREC D-Viewer CD,, - SIREC D200 ( ) ( ) ( ) / ( 4 ) ( ) 6 OPC- 8 7ND BA 7ND CA 7ND EA 7ND AA A5E A5E ) AL:N, ECCN: EAR99 :,, SIREC D ( SIREC D-Viewer).

12 - 4 8 SPCO 240 V - 8./.,, 24 V DC - 8 RS485 Modbus - RS485, MODBUS RTU ( ) , - 8 /. - CSA UL 24 V AC/DC V DC V AC 24 V DC ,. PCL- USB. SIREC D200 SIREC D200, ()

13 CJC 3 6- () B 4 8 () G 24V T, 2- / RS485 Modbus / USB A ( ) : NO =, C =, NC = 8 / () G SIREC D200 ( ) :

14 SIREC D300 SIREC D400 - (TFT) - SIREC D300: QVGA (320 x 240 ) - SIREC D400: SVGA (800 x 600 ) 10/100 Ethernet (DHCP), Web, , OPC- FTP, TCP/IP RS485 Modbus- USB Compact Flash USB - 21CFR 11 ESS.. Health Watch ( ) - CE, CSA, UL, FM NEMA 4/IP66 () 50 (20 ) - SIREC D300: 16 - SIREC D400: TFT- (SIREC D300)/5.5 TFT- (SIREC D400) ,, ,. :,

15 SIREC D300 SIREC D (SIREC D300) 30 (SIREC D400),,,. 4,, 6 (SIREC D300 SIREC D400)., 4., , 8., , 8. 8 DPMS 16..,.. "",. : ( ) FTP, Modbus TCP/IP ( - ), web - Ethernet ( DHCP) Modbus RTU ( -) RS485 (). USB- - - ASCII.. Ethernet Ethernet ( DHCP) (, LAN). Ethernet www. Dynamic Host Configuration Protocol (DHCP) (IP-) DHCP-. RS485 Modbus RS485,, MODBUS RTU ( ). Simple Network Time Protocol (SNTP) ethernet SNTP-,. Web-,, -;. USB- - USB. USB-, USB-. ( ),..., -.. Microsoft Internet explorer 6.

16 flash ,5 68, ( = 1 ) - SIREC D400,.,. SIREC D300 SIREC D Extended Security System () ESS, , ,. ESS ,5 68, CFR ( = 1 ) - SIREC D300 CE 73/23/EEC, USB- (flash) compact flash., -,. Compact flash USB-flash. -.,.,,,,,. 6 ""..,,. Fuzzy-. ;, -.,.,, - 100:1,. 8 / 4, - ( 4 ) /336/EEC. NEMA 3/IP54. - NEMA 4/IP66. ",.

17 SIREC D300 SIREC D400 SIREC D300 SIREC D400 SIREC D300 SIREC D400 - (TFT), 5.5 (14 ), 12.1 (30.7 ),. QVGA (320 x 240 ) SVGA (800 x 600 ) 1 720, %, - 80% SIREC D300 SIREC D400 USB , 100% ( %) /² , 100% ( %) /² - -,,. Ethernet 10/100 base - T RJ45 Modbus/TCP, FTP, Internet, DHCP IP-. RS485 Modbus RTU ( ).,,,,. () 100., SIN, COS, TAN, Log, (. A1 + A2),, (A1, P1, D1..) - USB. :, -, ( USB 1.1), -..,, , Screen Designer. Custom Screen. :,.,, 20-, Compact Flash, 1850 USB 2 USB 120, 70 (16 ) 1850 (400 ) () USB,,. ( ) FIFO (First In First Out), V AC 250 V AC () 50/60 - SIREC D300 < 40 - SIREC D400 < 60 - SIREC D V DC / V AC : < 40 - SIREC D V DC / V AC : < 60 () () 2, ( ), 24 V, 1 A,, 6032, 3.0 V 10 ( ), 4, ( ).

18 SIREC D300 SIREC D400,, ,,. 2-,. 3-, 4-, (.) C, F, K : ID, : ± 29 ppm (± 1 /) 25 C. /,. - Ethernet SNTP- / 6 ;., -, ± 100% 1 A, 24 V; -, CE ( CE) 1 / 5 / 10 / 20 / 30 / 60 / 120 / 600 / 1200 / 6000 / , : 73/23/EEC,., 89/336/EEC,. - - CE. EN I: -, -, (EN ) NEMA 3/ IP54 (: NEMA 4/IP66) II: (EN ) 2 - EN B - EN EN : 2001, SIREC D300 4, 6, 8, SIREC D400 4, 6, 8, 12, 16, 24, 32, (),, (- ),, -, - -, 4% 4% - (50 2%) (..), «-»/ (),, CJC

19 SIREC D300 SIREC D % (16- ) 10,. - ± 0.1%, > 1, > (Cu10 = 15 ) SIREC D300 SIREC D400-2, - 8 ; 6, - 8 ; 100 (10 ), 200 (5 ), 500 (2 ) 20 (50 ),, -, -, (10.) : , ( - 20 ) 300 V AC, 50/60 ± 2% - 2 = -120, 5 = -120, 10 = = -85, 5 = -80, 10 = -48 () mv (DC) V (DC) ma 4 20, B E J K R S T C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) L G (W_W26) C (W5, W26) M (NiMo-NiCo) (NNM90) N (Nicosil Nisil) Chromel/Copel P (Platinel) D Pt100 = 0,00385 Pt200 Pt500 Pt1000 Nickel, 100 Nickel, 120 Cu10 Cu C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F),, /, Fuzzy Fuzzy- / , 100:1 ;, - ; NEMA 3/IP54 NEMA 4/IP66 ( ) :. : SIREC D300 55, SIREC D400 70,

20 SIREC D300 SIREC D400 ( x x ) SIREC D x 144 x 200 SIREC D x 288 x 247 ( x ) SIREC D300 SIREC D400 SIREC D300 SIREC D (3.15 ) 138 x x C 50 C. (%RH) () (g) 0.1 (g) 1 () (±) 65 () (.) (DC) () SIREC D300 SIREC D400 IEC. - AC: < 40 (.), DC: < 40 (.). 20 AC: < 60 (.), DC: < 60 (.) IEEE / 1983 IEEE / 1987 () ,. < 1V,. > 4 V < 50 V :. =,. =. (6 ) 16 (SIREC D300) 48 (SIREC D400) 200 / / /. 4 8, 3 A 240 V AC, 3 A 24 V AC/DC, 0.2A 240 V DC (., ) 8 16./. -, 1 A 24 V DC (., ) /.. / 4, ( 1 4)... / / : -. () (C). 2 -, 6. < 500, > 300 k. Screen Designer..,.., : / /.,,,..,.,.,,,, OPC- OPC DA AE 3.0. OPC OPC,. 1/ ( ),,. /,,,,, -..,,,,,,, /,,../. SIREC D. - ; -. -, -.

21 SIREC D300 SIREC D400 - SIREC D SIREC D400 2, 4, ± 0.1% ( ), ± 0.25% ( 500, 1 k) 0 20, k 0,002% / CSA 300 V AC -. :. / 100% Compact Flash Hi/Lo CJC (. &.), / -. CSA22.2-No L UL ANSI/UL File # () SIREC D300 SIREC D400 Extended Security System (ESS) FM 1 2 () V DC ± 3 V DC 1 A 24 V DC ± 3 V DC 21 CFR 11. : - (1 10 ) (1 365 ) 50 3, ( 4 12 ) /. -. ( ) ()., Fo Po* C. - ( Z), Y, W V., - Z -,. Fo/Po /, z T..,,,.,. PCL- USB , 16 SIREC D SIREC D , -, (3 22 )

22 .,,. Factory. - 4, 100. ( 1) 6..:..., Y,... Z. ( 1) 6,.. :, /, //,,, / (),,./. ( 3) / 5 50 (20 ) SIREC D300: 8 SIREC D400: 16 4., ; (,..). Fo Po. ( 1) 4, SIREC D-Designer. ( 2) / 2.,,,, "", "",, 100%, Compact Flash, Hi/Lo CJC ( &.), /., 2 PCL- USB. 3 -.,,,. 2. SIREC D300 SIREC D400 Options: -. -,,,,.,,. 3., -. 3.,.., : / /.,,,..,.,.,,,, OPC- 8 OPC (OLE ). OPC,,,, Microsoft Windows (4) 2 4,.. SIREC D300: 16 SIREC D400: 48 (1) ( Extra Pens ),,,,. (2) Screen Designer SIREC D300 SIREC D400. (3),,,. (, ) :

23 SIREC D300 SIREC D400 SIREC D300 1) : 144 x 144,, : 200,, /500 /./ : Ethernet-; RS485; USB : CF; USB- SIREC D300 1) : 144 x 144,, : 200,, /500 /./ : Ethernet-; RS485; USB : CF; USB , V AC. 24 V DC, /48 V DC / 24 V AC, 50/60, / ,. 16, ,. 8,. 4 (240 V) 8, 2 (240 V) 8 (24 V / ) 16 (24 V / ) 70 () (ESS) (. ) ( ) IP54 IP66 (NEMA 4) 1) AL:N, ECCN: EAR99 :,, SIREC D ( SIREC D-Viewer). : CF-.

24 SIREC D300 SIREC D400 SIREC D400 1) : 288 x 288, 50 60, V AC. 24 V DC, /48 V DC / 24 V AC, 50/60, ( 1 4) , / ( 5 6) ,. ( 3 ) 4 (240 V) 8, 2 (240 V) 16, 4 (240 V) 24, 6 (240 V) 8 (24 V / ) 16 (24 V / / 1 x 16) 24 (24 V / /16 + 8) 48 (24 V / /3 x 16) SIREC D400 1) : 288 x 288, 70 () (ESS) (. ) ( ) IP54 IP66 (NEMA 4) 1) AL:N, ECCN: EAR99 :,, SIREC D ( SIREC D-Viewer). : CF-.

25 SIREC D300 SIREC D400 SIREC D300 SIREC D ND AC 20 7ND BC 30 7ND CC 40 7ND DC 50 7ND EC 60 7ND FC 70 ( SIREC D400) 7ND GC / SIREC D. SIREC D-Manager SIREC D-Server SIREC D-Designer ( SIREC D300 SIREC D400) SIREC D-Manager SIREC D-Server. SIREC D ; SIREC D200/D300/D400 ( CD),. SIREC D-Viewer CD,, - SIREC D300 SIREC D400 ( ) ( ) ( ) 7ND BA 7ND CA 7ND DA 7ND EA 7ND AA A5E A5E :,, SIREC D ( SIREC D-Viewer). : CF-. SIREC D300 / ( ) ( ) ( ) 4 6 ( ) ( ) 6 OPC- 8 4 (20 / //) SIREC D400 / ( ) ( ) ( ) ( ) ( ) 4 6 ( ) ( ) 6 OPC- 8 4 (20 / //) 5 5

26 SIREC D300 SIREC D SPCO 240 V /.,, 24 V DC - 16 SIREC D SIREC D : Nema 4/IP66 - Nema 4/IP66 - : , 8 8- / /.. -, 25 (SIREC D300:. 2 SIREC D400:. 6 ). - CSA, UL FM CL1 Div 2 24 V AC/DC 48 V DC V DC V AC 24 V DC (SIREC D300) 1 A (SIREC D400). -,. PCL- USB. SIREC D300 SIREC D300, ()

27 SIREC D300 SIREC D400 SIREC D400 SIREC D400, ()

28 SIREC D300 SIREC D400 CJC A B 24V T, G B / G A B ( ) 24 V : NO =, C =, NC =, NU =, Loop = SIREC D300 ( )

29 SIREC D300 SIREC D400 CJC 24 V T 4 8 G I E F / G I A F ( ) 24 V 10- : NO =, C =, NC =, NU =, Loop = SIREC D400 ( ) :

30 SIREC D SIREC D-Viewer, Manager Server SIREC D-Viewer SIREC D-Manager SIREC D-Viewer.. SIREC D-Manager,,, CSV. SIREC D-Server SIREC D-Server, (- ) 256. RS485, Ethernet TCP/IP,.,,, OPC. SIREC D-Manager SIREC D-Server,,,,. " " SIREC D-Server. SIREC D-Designer ( SIREC D300 SIREC D400) SIREC D-Designer,.,,,,,,.,. SIREC D-Designer SIREC D300, SIREC D400. /PC-.. SIREC D- Viewer SIREC D- Manager fuzzy- CSV OPC () 256 RS485 Ethernet TCP/IP FTP Ethernet Ethernet SIREC D- Server

31 SIREC D SIREC D-Viewer, SIREC D-Manager, SIREC D-Designer Pentium (. 512 ) SIREC D-Server 50 2 Microsoft Windows 2000, P 1024 x 768 (- ), high colour (16 ), 24 ( SIREC D- Designer) Pentium (. 512 ) Microsoft Windows 2000, P 1024 x 768 ( - ), high colour (- TCP/IP) Flash- USB- CD-ROM OPC- OPC 2.0. SIREC D 7ND AA ; SIREC D200/D300/D400 ( CD),. SIREC D-Viewer CD, / SIREC D. SIREC D-Manager 7ND BA SIREC D-Server 7ND CA SIREC D-Designer ( 7ND DA SIREC D300 SIREC D400) SIREC D-Manager 7ND EA SIREC D-Server

32

33 Siemens AG Automation and Drives Sensors and Communication KARLSRUHE GERMANY -,. -,. -., Siemens AG -,. E86060-K6020-E101-A3-7600

Siemens AG ED CB00-0BA0 6ED HB00-0BA0 6ED MB00-0BA1 6ED FB00-0BA1 Supply voltages Rated value

Siemens AG ED CB00-0BA0 6ED HB00-0BA0 6ED MB00-0BA1 6ED FB00-0BA1 Supply voltages Rated value Siemens AG 008 Overview Expansion modules for the connection to LOGO! Modular With digital inputs and outputs, analog inputs or analog outputs Technical specifications 1CB00-0BA0 1HB00-0BA0 1MB00-0BA1

More information

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples The Q.raxx slimline product is based on the standardized 19 technology, one rack unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field of stationary

More information

Q.raxx A slimline RS / EC

Q.raxx A slimline RS / EC The Q.raxx slimline product is based on the standardized 19 technology, one rack unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field of stationary

More information

Q.raxx A101-8 slimline RS / EC

Q.raxx A101-8 slimline RS / EC The Q.raxx slimline product is based on the standardized 19 technology, one rack mount unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field

More information

Q.raxx A slimline RS / EC Universal Measurement System

Q.raxx A slimline RS / EC Universal Measurement System Q.raxx A107-16 slimline RS / EC Universal Measurement System The Q.raxx slimline product is based on the standardised 19 technology, one rack unit (1 U) and is designed for measurements with a high level

More information

FL WLAN 24 AP XDB and RAD XDB

FL WLAN 24 AP XDB and RAD XDB FL WLAN 24 AP 802-11 XDB and RAD-80211-XDB 802.11a/b/g Ethernet radio AUTOMATION Data sheet 2592_en_B 1 Description PHOENIX CONT 2011-10-18 3 Features The radios are industrial radio transceivers that

More information

DIRIS A40/A41 ETHERNET. Operating instructions F GB D I NL E P

DIRIS A40/A41 ETHERNET. Operating instructions F GB D I NL E P DIRIS A40/A41 ETHERNET Operating instructions F GB D I NL E P 2 DIRIS A40/A41 - Ref.: 536 181 B GB GB Contents PRELIMINARY OPERATIONS 4 GENERAL INFORMATION 4 INSTALLATION 5 CONNECTION 5 VISUAL DIAGNOSTIC

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0 Overview The compact high-performance CPU With 2 integral input/outputs Expandable by: - 1 signal board (SB) or communication board (CB) - 8 signal modules (SM) - Max. 3 communication modules (CM) Technical

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading

More information

Wireless Sensor for Humidity / Temperature / CO 2

Wireless Sensor for Humidity / Temperature / CO 2 Series State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series. With a modular structure

More information

MULTIFUNCTION GRAPHICAL UNIT MGU 800

MULTIFUNCTION GRAPHICAL UNIT MGU 800 MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview Overview is a 4-wire, 6 GHz pulse radar level transmitter for continuous and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Auto False-Echo Suppression Infrared

More information

NEW! AOIP FD5 Advanced Digital Data Logger

NEW! AOIP FD5 Advanced Digital Data Logger NEW! AOIP FD5 Advanced Digital Data Logger Versatile data logger, each output channel can be custom configured for current, voltage, resistance, frequency, and temperature. The NEW! FD5 Digital Datalogger

More information

Visa Smart Debit/Credit Certificate Authority Public Keys

Visa Smart Debit/Credit Certificate Authority Public Keys CHIP AND NEW TECHNOLOGIES Visa Smart Debit/Credit Certificate Authority Public Keys Overview The EMV standard calls for the use of Public Key technology for offline authentication, for aspects of online

More information

Wireless Sensor for Humidity / Temperature / CO 2

Wireless Sensor for Humidity / Temperature / CO 2 State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series EE240. Wireless Sensor for Humidity

More information

C Mono Camera Module with UART Interface. User Manual

C Mono Camera Module with UART Interface. User Manual C328-7221 Mono Camera Module with UART Interface User Manual Release Note: 1. 16 Mar, 2009 official released v1.0 C328-7221 Mono Camera Module 1 V1.0 General Description The C328-7221 is VGA camera module

More information

SYSTEM DATA B, 3560-C, 3560-D, 3560-E PULSE IDA e PULSE TM PC PULSE LAN. Microsoft Windows OS Microsoft Office ch 3560-B C D E.

SYSTEM DATA B, 3560-C, 3560-D, 3560-E PULSE IDA e PULSE TM PC PULSE LAN. Microsoft Windows OS Microsoft Office ch 3560-B C D E. SYSTEM DATA 0-, 0-C, 0-D, 0-E PULSE IDA e PULSE TM PC PULSE PC LAN PULSE Microsoft Windows OS Microsoft Office 0 00ch 0- C D E 0 00ch 0- : ch ch 0-C : 7ch ch 0-D : 7 ch 0ch 0-E : 0 9ch ch PULSE Dyn-X 0d

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

Wireless Sensor for Humidity / Temperature / CO 2

Wireless Sensor for Humidity / Temperature / CO 2 State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series EE240. Indifferent whether a

More information

Trio Q Data Radios. Licensed UHF Ethernet and Serial Data QR450

Trio Q Data Radios. Licensed UHF Ethernet and Serial Data QR450 Trio Q Data Radios Licensed UHF Ethernet and Serial Data QR450 1 The Trio Q Data Radios are advanced high speed licensed digital data radios, which provide both Ethernet and serial communications for the

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

PAPERLESS RECORDER FEATURES SPECIFICATIONS PHL DATA SHEET. Input system

PAPERLESS RECORDER FEATURES SPECIFICATIONS PHL DATA SHEET. Input system PAPERLESS RECORDER DATA SHEET PHL This is a paperless recorder that displays measured data on the LCD in real time and stores data in CompactFlash. The type of input such as thermocouple, resistance, D.C.

More information

DPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS

DPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS EN0I-6021 06/2003 PRODUCT SPECIFICATION SHEET PRODUCT DESCRIPTION The DPR 100 C and D recorders are designed to meet the recording needs for most recording applications.

More information

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 SITANS TH00 two-wire system, universal Overview Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

Universal measuring transducer

Universal measuring transducer Universal measuring transducer EM4000 Compact housing High accuracy Full galvanic separation MODbus (RS232/RS485) 3 Analogue + 1 Pulse output Direct voltagemeasurement up to 690V 48 hour service EXW ELEQ

More information

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

DIN rail mounting temperature controller with current transformer input deltadue series D1 line BT.. D/E S E R I E S DIN rail mounting temperature controller with current transformer input deltadue series D line The controller with load control The deltadue series includes a powerful DIN rail mounting

More information

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2 PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Accutech BR10. Wireless base radio

Accutech BR10. Wireless base radio Accutech BR10 Wireless base radio 1 At the heart of any Accutech wireless instrument network is the BR10 wireless base radio. This device automatically communicates with all deployed instrumentation field

More information

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters The 520 transmitters are universal, isolated, dual-input temperature transmitters with additional voltage and resistance

More information

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I Memory 256 MB Alarm management Residual current measurement Homepage Ethernet-Modbus gateway BACnet (optional) UMG 96 RM-E Power analyser with Ethernet and RCM Communication Modbus (RTU, TCP, Gateway)

More information

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2 Series State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series. Indifferent whether a

More information

Side view View from below Rear view

Side view View from below Rear view Dimension diagrams All dimensions in mm Side view View from below Rear view Cut out: 138 +0,8 x 138 +0,8 mm Typical connection SPS SPS 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 DSUB-9 5 4 3 2 1 8 7 6 5 4

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

PC-supported measurement

PC-supported measurement PC-supported measurement Complete measurement data acquisition system Expert Key devices acquire and monitor measurement data and automate experiment and test stand installations. The devices are supplied

More information

UMG 509-PRO. Multifunction power analyser with RCM

UMG 509-PRO. Multifunction power analyser with RCM UMG 509-PRO Multifunction power analyser with RCM Power quality RCM Residual current monitoring Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management Communication Profibus (DP/V0)

More information

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/ ATC A-1 Serial Remote I/O Module User Manual V1.13 Edit:2018/01/30-1 - Catalogue 1.The introduction of Modbus protocol...- 3-1.1 Modbus protocol master-slave response process... - 3-1.2 Modbus register

More information

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM Power quality Colour graphical display Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management UMG 508 Multifunction power analyser Communication Profibus (DP/V0) Modbus (RTU,

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

Teleterm D3G Remote Terminal Unit

Teleterm D3G Remote Terminal Unit Monitor and control your remote assets securely via any web browser. Compatible with the Data2Desktop web service. ISaGRAF 611313 ready (order CC030A URTT to activate) 4 hour integrated battery backup

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

A Super trainer with advanced hardware and software features only found in very expensive equipment.

A Super trainer with advanced hardware and software features only found in very expensive equipment. PLC Trainer PTS T100 LAB EXPERIMENTS A Super trainer with advanced hardware and software features only found in very expensive equipment. You won t find any similar equipment among our competitors at such

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 Overview SITANS TH00 two-wire system, universal, HAT Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

Portable Multi-Channel Recorder Model DAS240-BAT

Portable Multi-Channel Recorder Model DAS240-BAT Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module DATA SHEET CAN bus-based I/O module 8 multi-functional inputs Selectable as: o Digital input, 0(4) to 20 ma, 0 to 10 V, RMI, Pt100, Pt1000, Thermocouple type E, J, K, N, R, S or T Wire break detection

More information

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC) Smart Energy & Power Quality Solutions UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC) UMG 96RM UMG 96RM Universal measurement instrument Unrivalled in its class The UMG 96RM is a

More information

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS

More information

Temperature Measurement

Temperature Measurement Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective

More information

Status Indicator LED PWR LINK COL

Status Indicator LED PWR LINK COL INSTRUCTION MANUAL DC VOLTAGE/CURRENT INPUT MODULE, 4 points (Ethernet Modbus/TCP) MODEL RE-SV4 RE-SV4 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you

More information

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485 cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement and recording of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS new! cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement of power network parameters in 3- or 4-wire balanced and unbalanced systems. Color graphic display: lcd TFT 3,5, 320

More information

Modular Metering System ModbusTCP Communications Manual

Modular Metering System ModbusTCP Communications Manual Modular Metering System Manual Revision 7 Published October 2016 Northern Design Metering Solutions Modular Metering System ModbusTCP 1 Description The multicube modular electricity metering system simultaneously

More information

Accutech BR20. DIN rail mounted base radio

Accutech BR20. DIN rail mounted base radio Accutech BR20 DIN rail mounted base radio 1 At the heart of any Accutech wireless instrument network is the wireless base radio. The Accutech BR20 automatically communicates with deployed instrumentation

More information

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2. EE240 v1.5. preliminary

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2. EE240 v1.5. preliminary preliminary EE40 Series State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series EE40.

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

STT 3000 Smart Temperature Transmitter Series STT170 Specifications STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable

More information

itemp HART DIN rail TMT112

itemp HART DIN rail TMT112 Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application

More information

Transienten. Datenspeicher

Transienten. Datenspeicher 25. 40. 63. Grenzwertüberwachung Oberschwingungen Power quality RCM Residual current monitoring Transienten Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management 32 MB 128 MB

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

General Specifications

General Specifications General Specifications MW100-E-1X/X/X/S15 Special Edition 1. MW100/S15 Hardware Specification MW100 Logging type Mainly standalone measurement and distributed remote measurement Style No. S3 Maximum number

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

Smart Energy & Power Quality Solutions. Power Quality Analyser UMG 512-PRO. Data sheet

Smart Energy & Power Quality Solutions. Power Quality Analyser UMG 512-PRO. Data sheet Smart Energy & Power Quality Solutions Power Quality Analyser Data sheet Dok.-Nr. 2.054.030.0 02/2019 DEVICE VIEWS Front view Rear view Side view Bottom view Cut-out size: 92 +0,8 mm x 92 +0,8 mm. All

More information

PAPERLESS RECORDER SPECIFICATIONS PHL DATA SHEET. Input system

PAPERLESS RECORDER SPECIFICATIONS PHL DATA SHEET. Input system PAPERLESS RECORDER DATA SHEET PHL This is a paperless recorder that displays measured data on the LCD in real time and stores data in CompactFlash. The type of input such as thermocouple, resistance, D.C.

More information

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils Class A DIN 192x144 power quality analyzer with Rogowski coils Current inputs for direct connection of Rogowski coils Harmonics and interharmonics measurement Data recording for further EN 50160 analysis

More information

MOBY-D Family Matrix

MOBY-D Family Matrix MOBY-D Family Matrix MOBY-D 13.56 MHz Passive Tags D100 6GT2600-0AD10 112 Bytes Min order of 50 D124 6GT2600-0AC00 112 Bytes D139 6GT2600-0AA00 44 Bytes D160 6GT2600-0AB00 44 Bytes D165 6GT2600-1AB00-0AX0

More information

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC) 6ES7214-1AG31-0XB0 Page 1 Product data sheet 6ES7214-1AG31-0XB0 SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature SITRANS T measuring instruments for temperature /2 Product overview /6 Transmitter for mounting in sensor head /6 SITRANS TH100, two-wire system (Pt100) /9 SITRANS TH200, two-wire system universal /15

More information

Temperature Measurement

Temperature Measurement Siemens AG 015 / Product overview Transmitters for mounting in sensor head /4 SITRANS TH100 two-wire system (Pt100) /8 SITRANS TH00 two-wire system universal /15 SITRANS TH00 two-wire system universal,

More information

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply

More information

A6500-UM Universal Measurement Card

A6500-UM Universal Measurement Card Specifications Sheet A6500-UM Universal Measurement Card The A6500-UM Universal Measurement Card is a component of the CSI 6500 ATG machinery protection system. The card is equipped with 2 sensor input

More information

Measuring is our strong point

Measuring is our strong point Measuring is our strong point Power measuring transducers E L E CT R O N manufacturing & services X About us In 2008 we established ElectronXx GmbH on the This catalogue presents our range of measuring

More information

WorkForce Pro WF-C5710 Network Multifunction Color Printer with Replaceable Ink Pack System

WorkForce Pro WF-C5710 Network Multifunction Color Printer with Replaceable Ink Pack System NEW WorkForce Pro WF-C5710 Network Multifunction Color Printer with Replaceable Ink Pack System Contact Us 800.463.7766 Mon-Fri 6am-8pm, Sat 7am-4pm PT Compact, cost-saving multifunction printer that drives

More information

Excellent low-cost Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200

More information

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets SILVER SERIES Low Cost, Single-Wavelength (1λ) Industrial Infrared Thermometers SSDS2013 Reliable compact industrial infrared thermometers for Temperatures below 3632 F/2000 C Non-reflective target materials

More information

8WD4 Signaling Columns

8WD4 Signaling Columns Siemens AG 200 General data Overview The 8WD4 signaling columns are flexible in design and versatile in use. 1 1 2 2 3 3 4 5 4 6 8 5 6 10 11 8 12 15 13 14 10 NSC0_002 11 12 NSC0_0026 1 Acoustic element

More information

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2] Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication

More information

Wireless sensor system

Wireless sensor system Wireless sensor system Internet / Ounet PC in internal network GW Internet connection FIGURE 1 structure of wireless sensor network = Base station = Routing wireless sensor = Wireless sensor General description

More information

Temperature head transmitter itemp TC TMT 188

Temperature head transmitter itemp TC TMT 188 Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed

More information

Chapter 6 Specifications

Chapter 6 Specifications RIGOL This chapter lists the technical specifications and general specifications of the RF signal generator. The technical specifications are valid when the instrument is within the calibration period,

More information

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard

More information

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature Transmitter itemp RTD DIN rail TMT 127 Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed

More information

Temperature Measurement

Temperature Measurement Siemens AG 017 / Product overview Transmitters for mounting in sensor head /4 SITRANS TH100 two-wire system (Pt100) /8 SITRANS TH00 two-wire system universal /15 SITRANS TH00 two-wire system universal,

More information

Cetetherm IQ Heat Midi/Maxi

Cetetherm IQ Heat Midi/Maxi Cetetherm IQ Heat Midi/Maxi Preconfigured DDC solution for Midi and Maxi. Ready to plug-in. Built in web pages for remote control. Quick feedback during alarms and deviations. No licens or extra programs

More information

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION GUIDE SPECIFICATIONS 256920-UGS-A-0506 Simplicity Intelli-Comfort Optional Control in 3-25 Ton Packaged Units GENERAL DESCRIPTION CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP Equipment with Simplicity

More information

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz 900 MHz FHSS DNT90/Ethernet Gateway Optional 128-Bit AES Encryption Point-to-point, Point-to-multipoint or Store and Forward Operation 158 mw EIRP 900 MHz Transmitter Power 10/100Base-T Auto-sensing Ethernet

More information

BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules

BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules Six Differential Current Inputs Six Differential Voltage Inputs USER S MANUAL ACROMAG INCORPORATED Tel: (248) 295-0880 30765

More information

SEN TRONIC AG ! "#! $ % & "! ' ( #& #$ #& ) * +,! ( ( ( 7 * 6 ( ) 6 * )! ( ( 7 * 6 ( ) 6 ( * ) ( ( / 8 6 ( ) 6 * )! ( ( / 8 6 ( ) 6 ( * )

SEN TRONIC AG ! #! $ % & ! ' ( #& #$ #& ) * +,! ( ( ( 7 * 6 ( ) 6 * )! ( ( 7 * 6 ( ) 6 ( * ) ( ( / 8 6 ( ) 6 * )! ( ( / 8 6 ( ) 6 ( * ) / (.+ + /.+/ +* /((* ) /0** /1(2*(/345*(*+ /.(( (2657/7/ **( (2 5 //)+*2 5 / *77 8 6( ) /9( (*. /3(2 5 /:946';")2 5 /(.666(+'. * ) /)(.66/(! "#!$ %&"! ' (#&#$#& )*+,!( -.! (( 7* 6( )6* )! (( 7* 6(

More information

100mm Recorders Specification Sheet

100mm Recorders Specification Sheet 4103C, 4103M MODELS 100mm Recorders Specification Sheet The 4103 is a high specification, 100mm strip chart recorder, providing continuous recording for up to 6 Process Variables. Information such as Channel

More information

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV Certificate Number 20081124 E29197A Page 1 of 8 Report Reference E29197, 1974 September 17 Issue Date 2008 November 24 Issued to: This is to certify that representative samples of SIEMENS ENERGY & AUTOMATION

More information

Temperature Controller

Temperature Controller Temperature Controller 1/8 IN - 48 x 96mm Platinum Series X400 Line Cost Effective Solutions This 48x96mm size controller of the Platinum Series, provides a high degree of functionality and reliability

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

PQube 3 Specifications

PQube 3 Specifications PQube 3 Specifications Reference conditions for factory tests: 19~25 C, 10%~70% RH MAINS VOLTAGE MEASURING CHANNELS Measurement Channels Power Configuration/ Range of Nominal Input Voltage 3 Line to Neutral,

More information

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications Data sheet DS/ EN Rev. F a rugged, reliable recorder for all single channel recording applications Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers

More information

PQA823 PQA824 Rel /01/2007

PQA823 PQA824 Rel /01/2007 Professional Power Quality Analyzers in compliance to EN50160 Pag 1 of 5 1. PQA82X INNOVATIVE FEATURES A wide (320x240pxls) graphical color TFT display with touch screen it s available for each model in

More information