Olympus Digital Microscope Camera (DP70) checklist

Size: px
Start display at page:

Download "Olympus Digital Microscope Camera (DP70) checklist"

Transcription

1 Smith College - July 2005 Olympus Digital Microscope Camera (DP70) checklist CONTENT, page no. Camera Information, 1 Startup, 1 Retrieve an Image, 2 Microscope Setup, 2 Capture, 3 Preview. 3 Color Balans, 4 Level Adjust, 4 User setting, 4 Scale, 4 Time Lapse, 5 Top Row functions (from left to right), 6 Image Composition, 7 Overlay, 7 Shut down, 7 ATTACHMENT 1: User settings that are saved, 8

2 Olympus Digital Microscope Camera (DP70) checklist Camera Information - Still images can be obtained using the Olympus DP70 camera Startup - Remove dust cover from Olympus BX51 compound microscope to which the Olympus DP70 camera is attached - If you are going to use the Olympus dissecting microscope, do the following: - Remove dust cover from the dissecting microscope - Remove dust cap - The Olympus DP70 camera is attached to the BX51 Olympus microscope with a U- PMTVC adapter. Use the Allan wrench that comes with the microscope to loosen the lower screw of the adapter. CARFULLY remove the Olympus DP70 camera with adapter from the Olympus BX51microscope and place it onto the dissecting microscope - Use Allan wrench to tighten lower screw of the adapter - If you are going to use the Olympus CH-2 compound microscope, do the following: - Remove dust cover from the CH-2 compound microscope - Remove dust cap - The Olympus DP70 camera is attached to the BX51 Olympus microscope with a U- PMTVC adapter. Use the Allan wrench that comes with the microscope to loosen the lower screw of the adapter. CARFULLY remove the Olympus DP70 camera with adapter from the Olympus BX51microscope and place it onto the CH-2 microscope - Use Allan wrench to tighten lower screw of the adapter - Turn on computer monitor - Turn on computer - A login screen (Novell Client for Window) appears - Select Workstation only if you do not want to be connected to the server. A User Name appears. Type in the password and select OK - Uncheck Workstation only if you want to be able to connect to the server. Type in your User Name and Novell password. Select OK. A Windows Workstation window opens and a User Name appears. Type in password and click OK 1

3 Retrieve an Image Microscope Setup - If using a compound microscope: - Turn microscope ON - Find specimen on slide using the microscope and change objective if needed - Set Köhler illumination to increase quality of obtained image. NOTE: Use Operating Checklist for Olympus BX51 for detailed instructions on how to setup the Olympus BX51 microscope - Pull out level with black knob on right side of oculars (sent light to the camera) - If using a dissecting microscope: - Turn microscope ON - Find specimen using the dissecting microscope - Set level on the right side of microscope to PHOTO and IN to sent light to the camera - Click on DPController icon. This opens an Olympus window to control the camera 2

4 Capture - Select the CAPTURE tab - Click on the eyeball with the bleu arrowhead (lower left) to get a live image on the computer screen. To focus image use focus knob on the microscope - Box (spot) selects area used for exposure calculations. Change the size of the exposure box (30%, 1%, 0.1%) in the Spot group - Make adjustments for size of image in the Still-image group. When image size 2040x1536 or 4080x3072 is selected in the Still-image group, pixel shifting (method for obtaining images with higher resolution) is performed. The time to capture an image will increase 9 times compared to the current exposure time (displayed in Still-image group) - To adjust exposure settings, make changes in the Exposure time group, Sensitivity group and Exposure group - To change exposure (slider in the Exposure group), select Manual in the Exposure Mode group. To increase (recommended for dark specimen) and decrease (recommended for bright specimen) the exposure in steps (bracket), select the correct adjustment in the Exposure time group - For bright-field, DIC, phase contrast, select Auto in Exposure Mode group - For fluorescence, select SFL-Auto in Exposure Mode group - When increasing sensitivity (higher ISO values) the exposure time is shortened. Note that this may increase the noise in your captured image - If a scale bar is displayed in your image, make sure the correct objective is selected in the Objective group - To decrease noise in an image captured from a noisy observation image, select the Average mode and specify a count in the Accumulation group - to provide contrast between the background of an observation image and the observation target region during fluorescence observation, select the Integral mode and specify a count in the Accumulation group. Adjust size of exposure box to the size of the target region to increase contrast in the captured image even more - To take a picture click on the camera icon. Your image will appear in DPManager - Save Images to your folder in the tempimages folder on the desktop or to another medium. Make a folder with your own name inside the tempimages folder if you don t have one. Make sure you back up your images regularly and delete them from your folder. THIS COMPUTER IS NOT A MEDIUM TO STORE IMAGES Preview - If an observation image is dark, the sensitivity can be increased to brighten the image. Use 2x2 or 4x4 in the Binning group to increase sensitivity 4 times and 16 times respectively. Note that the resolution of the observed image will decrease but the captured image will not be effected - If an observation image is noisy, the noise can be reduced by applying frame averaging selecting 2 frame in the Real-time frame average group. Note that this feature only reduces noise in the observation image and is not applied to captured images 3

5 Color Balance - Select COLOR BALANCE tab to correct for white balance (mainly for bright-field) and black balance (mainly for fluorescence) WHITE BALANCE - Select On and One Touch to adjust the color so that the color of the specified region (dropper) in the observation image is white - Select On and One Push to adjust the colors in the observation image so that the entire image looks white - Select On and adjust color balance levels for the color channels (Red, Green, Blue) using sliders BLACK BALANCE - Select On and One Touch to adjust the brightness of the observation image so the specified region (dropper) in the observation image is black - Select On and One Push to adjust the brightness of the observation image so that the entire image looks black Select On to adjust the brightness of the entire observation image using a slider Level Adjust - Select LEVEL ADJUST tab to image contrast by changing the intensity levels of the individual color channels (Red, Blue, Green). After adjustment per channel, combined intensity levels of the color channels can be adjusted User Setting - Use the USER SETTINGS tab to save software settings in order to use them again later - Save your User settings file in your folder inside the tempimages folder on the desktop - To load previous saved User settings, select load in de User settings group. Find and select your user settings and select open to apply user settings. See attachment I for information that is saved Scale - Select SCALE tab if you want to get a scale bar in your image - Check Show Scale in Display to add scale bar to your image - Select Free Size in Display to rotate or to adjust the size of the scale bar - Select Include in Image in Display for scale bar to show up in captured image - Select desired bar shape and add the size by selecting number style - To get the correct scale bar select the objective you use (circle w/ objectives) and make sure the adapter lens is set to 0.75x (0.3 mount X 2.5 photo eyepiece) - To change color or other features of the scale bar, place cursor on scale bar and right click on the mouse button 4

6 Time Lapse - Select TIMELAPSE tab if you want to record changes over time as a movie - Check if the Capture in timelapse mode in selected - In the figure below the relationship between Time to start capture, Interval of capture and Capturing time is shown: - Set the hours, minutes and seconds of Time to start capture using the up and down buttons - Set the hours, minutes and seconds of Interval of capture. This is the time between each image captured - Under Number of capture, set the total number of frames you want to collect - Check the Capture as AVI checkbox - Select the CAPTURE tab - Open the Size dropdown list and select the image size to be captured. NOTE: The maximum image size of the recorded movie is 1360 x Click on the capture button. The recorded movie is sent to the DP Manager 5

7 Top Row Functions (from left to right) - NORMAL - full field of view - ZOOM center of images is zoomed twice - FULL The resolution of the CCD is the whole screen displayed - FULL SCREEN Image is enlarged and displayed full screen on the desktop. Right click mouse button to get back to previous window - OVERLAY FLICKERING RESTRAINT The flickering of overlay graphics is restrained - BAR GRAPH DISPLAY Display focus indicator as bar graph - PROFILE Display focus as profile. An intensity profile (RGB) along the gray line in image is shown - NUMBER DISPLAY Display focus indicator numerically ( Current and Max ) - FOCUS RESET Reset focus indicator value to adjust Max value to Current value (only if Number Display is selected) - ONE TOUCH WHITE BALANCE Color is adjusted so that the color of the specified region (dropper) in the observed image is white - ONE TOUCH BLACK BALANCE Brightness of the observation image is adjusted so that the specified region (dropper) in the observation image is black - ONE PUSH WHITH BALANCE Colors in the observation image are adjusted so that the entire image looks white - ONE PUSH BLACK BALANCE - Brightness of the observation image is adjusted so that the entire image looks black - ROTATE 180 Image is rotated FLIP HORIZONTALLY Flip image horizontally - FLIP VERTICALLY Flip image vertically - GRAYSCALE The color display is switched to gray scale - CLIP REGION Clip region is specified. Adjust size if needed - TEXT INPUT Add text to your image. Go to image and select an area (click and drag mouse). An Edit Text window opens to write your text - APPEND TO STILL IMAGE The text in the image preview will be included in the captured image (only if Text Input is selected) - 16 BITS CHANNEL The bits of color per channel of the image is changed from 8 to 16 - MINIMUM SHARPNESS The image is sharpened lightly - NORMAL SHARPNESS The image is sharpened moderately - MAXIMUM SHARPNESS The image is sharpened heavily - HELP Launches DP Controller Help window in case you have questions about the different functions or buttons 6

8 Image Composition Overlay - Open all images you want to overlay in DP Manager. Go to tempimages folder and drag desired images into DP Manager window - Select the Image Composition icon to display the Image Composition window È - In the mode group, select Normal - In the image group, select a composite candidate image in the dropdown menu. The checkbox in the left of a composite candidate image list is checked. To clear a selected image, click on the check box in the left of the drop-down list - To fine adjust the position of the composed image, click on the up and down buttons in the XY Position group - Adjust the intensity of the brightness of each image by using the up and down buttons in the Colors/Intensities group - To increase zoom, use the slider in the zoom group or enter the desired zoom ratio directly in the box below the slider. Selecting Fit to window button displays the image filling the preview area. When selecting the 100% button, each of the image pixels will be represented by a monitor pixel - If the previewed composite image at the top left of the window is acceptable, select Apply. The overlay image will appear in the DP Manager Shut Down - Did you save your image(s)? - Close Olympus window and DP Manager window - Go to START, select SHUTDOWN and select OK in the shutdown window - Wait for the computer to shut down - Turn of the monitor - Remove the sample and turn of the microscope (default setting Æ bright-field) - If you attached the camera to the Olympus CH-2 microscope or the dissecting microscope, make sure to remove the camera w/adapter and attach it to the Olympus BX51 microscope - Leave the room CLEAN and TIDY.AS ALWAYS!!!! NOTE: If you have any questions or if you need help, ask Judith Wopereis (SR437) or Dick Briggs (SR436) 7

9 ATTACHMENT I User settings that are saved 8

10 9

11 Click below to find more Mipaper at Mipaper at

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE University of Virginia ITC Academic Computing Health Sciences CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE Introduction The Olympus BH-2 microscope in ACHS s microscope lab has objectives from

More information

Olympus IX71 Microscope and DP71 Camera Instructions

Olympus IX71 Microscope and DP71 Camera Instructions Olympus IX71 Microscope and DP71 Camera Instructions Microscopy in Medicine (MiM) Core Emory University Department of Medicine 1 Olympus IX71 Image Capture Procedure 2 3 1. STARTING-UP PROCEDURE: Remove

More information

Brightfield Microscopy and Image Acquisition on Spotcam1. by Ryan Taylor/Nancy Kleene Last modified 10/02/05 by Birgit Ehmer

Brightfield Microscopy and Image Acquisition on Spotcam1. by Ryan Taylor/Nancy Kleene Last modified 10/02/05 by Birgit Ehmer Brightfield Microscopy and Image Acquisition on Spotcam1 by Ryan Taylor/Nancy Kleene Last modified 10/02/05 by Birgit Ehmer Log onto the computer. Enter your username and password to log onto the server.

More information

Zeiss Axio Imager.A1 manual

Zeiss Axio Imager.A1 manual Zeiss Axio Imager.A1 manual Power-up protocol 1. Mercury lamp 2. Power strip on shelf 3. Computer The Mercury lamp should always be first-on and last-off. This prevents any electrical surges caused by

More information

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center For any questions or concerns, please contact: Linda Nieman lnieman@mgh.harvard.edu Office: (617) 643-9684 Cell: (512) 565-8076 Chenyue

More information

Simplified Instructions: Olympus Widefield Microscope S1230

Simplified Instructions: Olympus Widefield Microscope S1230 Contents General Microscope Operation Simple Image Capture Multi-Wavelength Capture Z-Series Timelapse Combining Capture Modes Synopsis of Other Functions Pages 2-23 24-40 41-47 48-56 57-59 60-68 69-83

More information

User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras

User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras The TWAIN & DirectX driver for PROGRES GRYPHAX USB 3.0 cameras enables user to operate with TWAIN and DirectX supported 3 rd party software

More information

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center For any questions or concerns, please contact: Linda Nieman lnieman@mgh.harvard.edu Office: (617) 643-9684 Cell: (512) 565-8076 Chenyue

More information

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING Operations Guide Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING Nikon Eclipse 90i Operations Guide STARTUP Startup Powering Up Fluorescence

More information

Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope

Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope ZEN 2012 Optical Imaging & Vital Microscopy Core Baylor College of Medicine (2017) Power ON Routine 1 2 If you require fluorescence imaging,

More information

Using the AmScope Microscope Cameras

Using the AmScope Microscope Cameras Using the AmScope Microscope Cameras Part 1 Setup. In order to use the camera, you will need: a) the camera system; b) a computer running the camera software. The camera system is contained in a Pelican

More information

Olympus Time-lapse Microscope Basic operation

Olympus Time-lapse Microscope Basic operation Olympus Time-lapse Microscope Basic operation To start up the microscope 1. Switch on the Olympus UCB. (label as ) 1 Power Switch 2 2. Switch on the MT10. (label as ) Power Switch Page 1 of 18 3 3. Switch

More information

Apple Photos Quick Start Guide

Apple Photos Quick Start Guide Apple Photos Quick Start Guide Photos is Apple s replacement for iphoto. It is a photograph organizational tool that allows users to view and make basic changes to photos, create slideshows, albums, photo

More information

AxioVision 4.5 Brightfield Image Capture Procedure

AxioVision 4.5 Brightfield Image Capture Procedure AxioVision 4.5 Brightfield Image Capture Procedure 1. STARTING-UP PROCEDURE: Remove blue dust cover and place on shelf under microscope. Turn on the halogen lamp by pushing the switch at the back right

More information

QUICKSTART GUIDE: WIDEFIELD HWF1 Zeiss Cell Observer Live Cell Imaging System (HAMMERSMITH, L BLOCK, ROOM 314) Imperial College London

QUICKSTART GUIDE: WIDEFIELD HWF1 Zeiss Cell Observer Live Cell Imaging System (HAMMERSMITH, L BLOCK, ROOM 314) Imperial College London Imperial College London Facility for Imaging by Light Microscopy QUICKSTART GUIDE: WIDEFIELD HWF1 Zeiss Cell Observer Live Cell Imaging System (HAMMERSMITH, L BLOCK, ROOM 314) Observing Life As It Happens

More information

Guidance on Using Scanning Software: Part 5. Epson Scan

Guidance on Using Scanning Software: Part 5. Epson Scan Guidance on Using Scanning Software: Part 5. Epson Scan Version of 4/29/2012 Epson Scan comes with Epson scanners and has simple manual adjustments, but requires vigilance to control the default settings

More information

Proudly serving laboratories worldwide since 1979 SPECIFICATIONS

Proudly serving laboratories worldwide since 1979 SPECIFICATIONS www.ietltd.com Proudly serving laboratories worldwide since 1979 SPECIFICATIONS Scan RDI Specifications System Components Main analytical console Laser Module CRT Printer Data Manager Motorized stage (option)

More information

Nasmyth Ultraview Vox User Protocol

Nasmyth Ultraview Vox User Protocol Nasmyth Ultraview Vox User Protocol Switch on all wall sockets labelled Nasmyth, switch camera on (power supply located on table behind monitor), switch on laser switch in laser rack, switch computer on

More information

Ch. 1 - Installation Guidelines

Ch. 1 - Installation Guidelines Ch. 1 - Installation Guidelines Table of Contents Ch. 1 - Installation Guidelines Introduction... 8 The Image-Pro Driver Interface... 8 Installing the SPOT Image-Pro Driver... 8 Image-Pro Driver Supplement

More information

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000 The ideal K-12 science microscope solution User Guide for use with the Nova5000 NovaScope User Guide Information in this document is subject to change without notice. 2009 Fourier Systems Ltd. All rights

More information

Zeiss AxioImager.Z2 Brightfield Protocol

Zeiss AxioImager.Z2 Brightfield Protocol Zeiss AxioImager.Z2 Brightfield Protocol 1) System Startup Please note put sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge

More information

Motic Live Imaging Module. Windows OS User Manual

Motic Live Imaging Module. Windows OS User Manual Motic Live Imaging Module Windows OS User Manual Motic Live Imaging Module Windows OS User Manual CONTENTS (Linked) Introduction 05 Menus, bars and tools 06 Title bar 06 Menu bar 06 Status bar 07 FPS 07

More information

Nikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope

Nikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope Nikon Eclipse Ti A1-A Confocal Operating Manual Start-up 1. Turn on Excite Fluorescent light power supply- metal halide. a. Cool down as for mercury bulb b. Wheel closed liquid light guide 2. Turn on power

More information

EPIFLUORESCENCE &/OR BRIGHTFIELD MICROSCOPY

EPIFLUORESCENCE &/OR BRIGHTFIELD MICROSCOPY EPIFLUORESCENCE &/OR BRIGHTFIELD MICROSCOPY TURN ON THE FOLLOWING EQUIPMENT The fluorescent light (if needed) The power strip for the microscope and accessories The CoolSNAP HQ camera on the right (Turn

More information

MEASUREMENT CAMERA USER GUIDE

MEASUREMENT CAMERA USER GUIDE How to use your Aven camera s imaging and measurement tools Part 1 of this guide identifies software icons for on-screen functions, camera settings and measurement tools. Part 2 provides step-by-step operating

More information

ISCapture User Guide. advanced CCD imaging. Opticstar

ISCapture User Guide. advanced CCD imaging. Opticstar advanced CCD imaging Opticstar I We always check the accuracy of the information in our promotional material. However, due to the continuous process of product development and improvement it is possible

More information

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL MIF ZEISS LSM510 CONFOCAL USER PROTOCOL START-UP Turn on the Mercury Bulb Power Supply (if needed). Power-on the Control Box. Turn on the computer. Open the LSM 510 software. Choose Scan New Images and

More information

Contents Navigating in This Document DMC 2 Camera Features Taking Pictures Typical Pic

Contents Navigating in This Document DMC 2 Camera Features Taking Pictures Typical Pic DMC 2 Online User Guide Contents Navigating in This Document................. 7 DMC 2 Camera Features................... 9 Taking Pictures..................... 12 Typical Picture-Taking Sequence......................

More information

Zeiss Deconvolution Microscope: A Quick Guide

Zeiss Deconvolution Microscope: A Quick Guide Zeiss Deconvolution Microscope: A Quick Guide Start-up Uncover microscope. Do not put dust cover on the floor. Plug in both cameras. The default camera is the AxioCam HRm (monochrome camera) for fluorescence

More information

LSM 780 Confocal Microscope Standard Operation Protocol

LSM 780 Confocal Microscope Standard Operation Protocol LSM 780 Confocal Microscope Standard Operation Protocol Basic Operation Turning on the system 1. Sign on log sheet according to Actual start time 2. Check Compressed Air supply for the air table 3. Switch

More information

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2:

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2: Image acquisition, managing and processing software TCapture Instruction Manual Key to the Instruction Manual TC is shortened name used for TCapture. Help Refer to [Help] >> [About TCapture] menu for software

More information

Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software

Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software September 2007 Check website for most current User Guide

More information

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5. Smith College August 2010 Operating Checklist for using the Laser Scanning Confocal Microscope Leica TCS SP5. CONTENT, page no. Startup, 1 Initial set-up, 1 Software, 2 Microscope Specimen observation

More information

Color and More. Color basics

Color and More. Color basics Color and More In this lesson, you'll evaluate an image in terms of its overall tonal range (lightness, darkness, and contrast), its overall balance of color, and its overall appearance for areas that

More information

Zeiss LSM 880 Protocol

Zeiss LSM 880 Protocol Zeiss LSM 880 Protocol 1) System Startup Please note put sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused time.

More information

Leica DB LB Research microscope and Studo Lite Imaging software

Leica DB LB Research microscope and Studo Lite Imaging software Leica DB LB Research microscope and Studo Lite Imaging software Room B523 User Guide Molecular Imaging Unit University of Helsinki www.miu.helsinki.fi 9.4.2008 1 GENERAL USER INFORMATION... 1 2 SETTINGS

More information

Using the zoom adjustment, zoom on the gel Adjust the tray on the VGAU 3000 to see the image of the gel in the viewfinder

Using the zoom adjustment, zoom on the gel Adjust the tray on the VGAU 3000 to see the image of the gel in the viewfinder Operation of Vakili 3000 Gel Analysis Unit Both qualitative and quantitative analysis of electrophoresis experiments can be accomplished by using the Vakili 3000 Gel Analysis Unit. There are three steps

More information

User Guide of ISCapture

User Guide of ISCapture User Guide of ISCapture For Windows2000/XP/Vista(32bit/64bit)/Win7(32bit/64bit) Xintu Photonics Co., Ltd. Version: 2.6 I All the users of Xintu please kindly note that the information and references in

More information

Widefield 1. Switching on

Widefield 1. Switching on Widefield 1 Switching on 1. Ignite DG5 lamp - must be switched on first (if previous user has switched off, wait 30 min before igniting) 2. Wait 5s and then turn on the main DG5 controller switch. 3. DG5

More information

Photoshop CC Editing Images

Photoshop CC Editing Images Photoshop CC Editing Images Rotate a Canvas A canvas can be rotated 90 degrees Clockwise, 90 degrees Counter Clockwise, or rotated 180 degrees. Navigate to the Image Menu, select Image Rotation and then

More information

MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL

MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL START-UP On the Switchbox, turn both black switches to the ON position. Wait for the microscope to boot up completely (watch the screen on the side of the microscope).

More information

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide Operation 58. UltraVIEW VoX Getting Started Guide Overview This chapter outlines the basic methods used to operate the UltraVIEW VoX system. About other software Volocity places great demands on the computer

More information

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual Scanning Electron Microscope FEI INSPECT F50 Step by step operation manual Scanning Electron Microscope, FEI Inspect F50 FE-SEM-F Observation Flow Saving Data And Analysis Specimen preparation Error check

More information

Instructions for Making On-Line Reservations for Microscopes in NB11-204

Instructions for Making On-Line Reservations for Microscopes in NB11-204 Instructions for Making On-Line Reservations for Microscopes in NB11-204 1. Log into Mail using Mail.swmed.edu 2. Log in using your university id and password. 3. Click the Calendar Tab at the top right

More information

ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide

ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide Copyright Notice 1999 Canon Inc. This manual is copyrighted with all rights reserved. Under the copyright laws, this manual

More information

Olympus xcellence Software - basic user guide

Olympus xcellence Software - basic user guide Olympus xcellence Software - basic user guide This is a basic overview of setting up time lapse experiments using Olympus's xcellence software on BIU's IX81 inverted phase contrast system - the software

More information

TRAINING MANUAL. Olympus FV1000

TRAINING MANUAL. Olympus FV1000 TRAINING MANUAL Olympus FV1000 September 2014 TABLE OF CONTENTS A. Start-Up Procedure... 1 B. Visual Observation under the Microscope... 1 C. Image Acquisition... 4 A brief Overview of the Settings...

More information

Operating Instructions for Zeiss LSM 510

Operating Instructions for Zeiss LSM 510 Operating Instructions for Zeiss LSM 510 Location: GNL 6.312q (BSL3) Questions? Contact: Maxim Ivannikov, maivanni@utmb.edu 1 Attend A Complementary Training Before Using The Microscope All future users

More information

Select your Image in Bridge. Make sure you are opening the RAW version of your image file!

Select your Image in Bridge. Make sure you are opening the RAW version of your image file! CO 3403: Photographic Communication Steps for Non-Destructive Image Adjustments in Photoshop Use the application Bridge to preview your images and open your files with Camera Raw Review the information

More information

Renishaw InVia Raman microscope

Renishaw InVia Raman microscope Laser Spectroscopy Labs Renishaw InVia Raman microscope Operation instructions 1. Turn On the power switch, system power switch is located towards the back of the system on the right hand side. Wait ~10

More information

Manual. ios App. Ver2.2. v Mall Drive, Commack, NY (P) (F)

Manual. ios App. Ver2.2. v Mall Drive, Commack, NY (P) (F) Manual Ver2.2 ios App v1.6 73 Mall Drive, Commack, NY 11725 631-864-1000 (P) 631-543-8900 (F) www.accu-scope.com info@accu-scope.com Contents CHAPTER 1: SYSTEM REQUIREMENT & SOFTWARE -------------------------------------

More information

INSTRUCTION MANUAL MM-A209

INSTRUCTION MANUAL MM-A209 E INSTRUCTION MANUAL 9222-7300-11 MM-A209 2 BEFORE YOU BEGIN Before installing the DiMAGE Viewer software, read the data-transfer section in the camera manual. This section details how to connect the camera

More information

GXCapture 8.1 Instruction Manual

GXCapture 8.1 Instruction Manual GT Vision image acquisition, managing and processing software GXCapture 8.1 Instruction Manual Contents of the Instruction Manual GXC is the shortened name used for GXCapture Square brackets are used to

More information

GlobiScope Analysis Software for the Globisens QX7 Digital Microscope. Quick Start Guide

GlobiScope Analysis Software for the Globisens QX7 Digital Microscope. Quick Start Guide GlobiScope Analysis Software for the Globisens QX7 Digital Microscope Quick Start Guide Contents GlobiScope Overview... 1 Overview of home screen... 2 General Settings... 2 Measurements... 3 Movie capture...

More information

Nikon E800 Operating Instructions.

Nikon E800 Operating Instructions. Nikon E800 Operating Instructions. You can request electronic copies of this manual by contacting lshats@jhsph.edu Copies are also available on the JHU MMI Department web site. Please send your comments

More information

CHROMACAL User Guide (v 1.1) User Guide

CHROMACAL User Guide (v 1.1) User Guide CHROMACAL User Guide (v 1.1) User Guide User Guide Notice Hello and welcome to the User Guide for the Datacolor CHROMACAL Color Calibration System for Optical Microscopy, a cross-platform solution that

More information

Mullingar Camera Club Basic introduction to Digital Printing using Photoshop CC.

Mullingar Camera Club Basic introduction to Digital Printing using Photoshop CC. Mullingar Camera Club Basic introduction to Digital Printing using Photoshop CC. Table of Contents Course aims: 1 Course presentation notes: 1 Introducing Photoshop: 1 Adjusting the Brightness or Contrast

More information

LSM 710 Confocal Microscope Standard Operation Protocol

LSM 710 Confocal Microscope Standard Operation Protocol LSM 710 Confocal Microscope Standard Operation Protocol Basic Operation Turning on the system 1. Switch on Main power switch 2. Switch on System / PC power button 3. Switch on Components power button 4.

More information

LSM 800 Confocal Microscope Standard Operation Protocol

LSM 800 Confocal Microscope Standard Operation Protocol LSM 800 Confocal Microscope Standard Operation Protocol Turning on the system 1. Switch on the Main switch (labeled 1 and 2 ) mounted on the wall. 2. Turn the Laser Key (labeled 3 ) 90 clockwise for power

More information

MetaMorph Imaging Handbook Update 6/4/13

MetaMorph Imaging Handbook Update 6/4/13 MetaMorph Imaging Handbook Update 6/4/13 Startup FIRST turn on mercury lamp (Fluorescence) Computer and monitor Qimaging Camera (on top) Uniblitz Shutters-2 Halogen Lamp (Transmitted Light) Computer Login

More information

Microscopy from Carl Zeiss

Microscopy from Carl Zeiss Microscopy from Carl Zeiss Contents Page Contents... 1 Introduction... 1 Starting the System... 2 Introduction to ZEN Efficient Navigation... 5 Setting up the microscope... 10 Configuring the beam path

More information

Zeiss Axiovert 135 Fluorescence Microscope Quick Guide / Operations Manual (v. 1.0 February 09)

Zeiss Axiovert 135 Fluorescence Microscope Quick Guide / Operations Manual (v. 1.0 February 09) University of Chicago Integrated Light Microscopy Core Dr. Vytas Bindokas, Director http://digital.bsd.uchicago.edu By: Christine Labno, Assistant Director Room: AB-129 Phone: 4-9040 Zeiss Axiovert 135

More information

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0 DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0 PixeLINK for Microscopy Applications PixeLINK will work with you to choose and integrate the optimal USB 3.0 camera for your microscopy project. Ideal for use

More information

Leica SP8 TCS Users Manual

Leica SP8 TCS Users Manual Version : 07/08/0 Leica SP8 TCS Users Manual Start up:. Turn the PC Microscope, Scanner Power, Laser Power, and the Laser Emission key to on (bottom right of desk).. Turn on the fluorescent lamp (top left

More information

Photoshop Elements Hints by Steve Miller

Photoshop Elements Hints by Steve Miller 2015 Elements 13 A brief tutorial for basic photo file processing To begin, click on the Elements 13 icon, click on Photo Editor in the first box that appears. We will not be discussing the Organizer portion

More information

Title: Leica SP5 Confocal User Manual

Title: Leica SP5 Confocal User Manual Title: Leica SP5 Confocal User Manual Date of first issue: 23/10/2015 Date of review: Version: Admin For assistance or to report an issue Office: CG07 or 05 Email: Igmm-imaginghelpdesk@igmm.ed.ac.uk Website:

More information

Standard Operating Procedure (SOP) for Shared Equipment: Spinning Disk Confocal Microscope

Standard Operating Procedure (SOP) for Shared Equipment: Spinning Disk Confocal Microscope Standard Operating Procedure (SOP) for Shared Equipment: Spinning Disk Confocal Microscope This document is to be used as a supplementary guide and not as a replacement for formal training. DO NOT operate

More information

Adobe Photoshop. Levels

Adobe Photoshop. Levels How to correct color Once you ve opened an image in Photoshop, you may want to adjust color quality or light levels, convert it to black and white, or correct color or lens distortions. This can improve

More information

The Main Screen. Viewing Area - show the photos that were selected in the Source List.

The Main Screen. Viewing Area - show the photos that were selected in the Source List. iphoto 11 The Main Screen Source List - This is where the Library, Events and Albums are identified. It is the place where photos can be organized and accessed. The Source List can also contain the slideshows,

More information

Things to check before start-up.

Things to check before start-up. Byeong Cha Page 1 11/24/2009 Manual for Leica SP2 Confocal Microscope Enter you name, the date, the time, and the account number in the user log book. Things to check before start-up. Make sure that your

More information

Introduction to: Microsoft Photo Story 3. for Windows. Brevard County, Florida

Introduction to: Microsoft Photo Story 3. for Windows. Brevard County, Florida Introduction to: Microsoft Photo Story 3 for Windows Brevard County, Florida 1 Table of Contents Introduction... 3 Downloading Photo Story 3... 4 Adding Pictures to Your PC... 7 Launching Photo Story 3...

More information

μscope Microscopy Software

μscope Microscopy Software μscope Microscopy Software Pixelink μscope Essentials (ES) Software is an easy-to-use robust image capture tool optimized for productivity. Pixelink μscope Standard (SE) Software had added features, making

More information

Editing your digital images:

Editing your digital images: Editing your digital images: 1 By Garry Sankowsky zodpub@rainforestmagic.com.au All images taken with a digital camera need to be edited. You will usually get software with your camera that can do at least

More information

Leica DFC Cameras. Image Acquisition

Leica DFC Cameras. Image Acquisition Leica DFC Cameras Image Acquisition Leica DFC Cameras Image Acquisition All reasonable steps have been taken to ensure that this publication is correct and complete, but should any user be in doubt about

More information

University Libraries ScanPro 3000 Microfilm Scanner

University Libraries ScanPro 3000 Microfilm Scanner University Libraries ScanPro 3000 Microfilm Scanner Help Guide Table of Contents Getting Started 3 Loading the Film 4-5 Viewing Your Film 6-7 Motorized Roll Film Control 6 Crop Box 7 Using the Toolbar

More information

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide Nikon C1si Spectral Laser Scanning Confocal Microscope User Guide Contents: C1Si Turn-On/ShutDown Procedures... 2 Overview... 4 Setup for epi-illumination to view through the eyepieces:... 5 Setup for

More information

ACDSee Pro 3 tutorials: Process mode overview

ACDSee Pro 3 tutorials: Process mode overview ACDSee Pro 3 tutorials: Process overview After you have organized and viewed your images in Manage and View s, you are ready to take your images into Process for developing and editing. Start in to do

More information

GlassSpection User Guide

GlassSpection User Guide i GlassSpection User Guide GlassSpection User Guide v1.1a January2011 ii Support: Support for GlassSpection is available from Pyramid Imaging. Send any questions or test images you want us to evaluate

More information

OTHER RECORDING FUNCTIONS

OTHER RECORDING FUNCTIONS OTHER RECORDING FUNCTIONS This chapter describes the other powerful features and functions that are available for recording. Exposure Compensation (EV Shift) Exposure compensation lets you change the exposure

More information

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7 Leica DMI AF6000LX Table of contents START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7 ACQUIRE MODULE 6 SETTING THE LIGHTPATH 6

More information

LEICA TCS SP5 AOBS TANDEM USER MANUAL

LEICA TCS SP5 AOBS TANDEM USER MANUAL LEICA TCS SP5 AOBS TANDEM USER MANUAL STARTING THE SYSTEM...2 THE LAS AF SOFTWARE...3 THE «ACQUIRE» MENU...5 CHOOSE AND CREATE A SETTING...6 THE CONTROL PANEL...8 THE DMI6000B MICROSCOPE...10 ACQUIRE ONE

More information

Basic Users Manual for Tecnai-F20 TEM

Basic Users Manual for Tecnai-F20 TEM Basic Users Manual for Tecnai-F20 TEM NB: This document contains my personal notes on the operating procedure of the Tecnai F20 and may be used as a rough guide for those new to the microscope. It may

More information

Image Pro Ultra. Tel:

Image Pro Ultra.  Tel: Image Pro Ultra www.ysctech.com info@ysctech.com Tel: 510.226.0889 Instructions for installing YSC VIC-USB and IPU For software and manual download, please go to below links. http://ysctech.com/support/ysc_imageproultra_20111010.zip

More information

Nikon TE300 Eclipse Wide-Field Microscope

Nikon TE300 Eclipse Wide-Field Microscope Nikon TE300 Eclipse Wide-Field Microscope User Guide LSU Health Science Center-Shreveport Research Core Facility 1 User manual for Nikon Elements software Equipment: Nikon TE300 Eclipse microscope Photometrics

More information

KODAK DIGITAL ROC Professional Plug-In 2.1

KODAK DIGITAL ROC Professional Plug-In 2.1 KODAK DIGITAL ROC Professional Plug-In 2.1 Installing Kodak's DIGITAL ROC Professional Plug-In If you have not downloaded and installed DIGITAL ROC Professional, go to: http://www.asf.com/download/ Download

More information

Picture Style Editor Ver Instruction Manual

Picture Style Editor Ver Instruction Manual ENGLISH Picture Style File Creating Software Picture Style Editor Ver. 1.15 Instruction Manual Content of this Instruction Manual PSE stands for Picture Style Editor. indicates the selection procedure

More information

QUICKSTART GUIDE: WIDEFIELD WF3 Zeiss Cell Observer Live Cell Imaging System (SAF, ROOM 409) Imperial College London

QUICKSTART GUIDE: WIDEFIELD WF3 Zeiss Cell Observer Live Cell Imaging System (SAF, ROOM 409) Imperial College London Imperial College London Facility for Imaging by Light Microscopy QUICKSTART GUIDE: WIDEFIELD WF3 Zeiss Cell Observer Live Cell Imaging System (SAF, ROOM 409) Observing Life As It Happens Startup procedure...

More information

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol Nikon Eclipse Ti-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol Please sign on the log sheet before switching on system. Turn on system Turn on A only if confocal mode or laser

More information

Quick Start Training Guide

Quick Start Training Guide Quick Start Training Guide To begin, double-click the VisualTour icon on your Desktop. If you are using the software for the first time you will need to register. If you didn t receive your registration

More information

Characterization Microscope Nikon LV150

Characterization Microscope Nikon LV150 Characterization Microscope Nikon LV150 Figure 1: Microscope Nikon LV150 Introduction This upright optical microscope is designed for investigating up to 150 mm (6 inch) semiconductor wafers but can also

More information

Optika ISview. Image acquisition and processing software. Instruction Manual

Optika ISview. Image acquisition and processing software. Instruction Manual Optika ISview Image acquisition and processing software Instruction Manual Key to the Instruction Manual IS is shortened name used for OptikaISview Square brackets are used to indicate items such as menu

More information

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions Starting up: Schematic of Olympus BX-61. 1. Turn on Olympus microscope power box (left of microscope) with toggle switch on

More information

Workflow for Betterlight Imaging

Workflow for Betterlight Imaging Workflow for Betterlight Imaging [1] Startup Check that camera lens shutter is fully open Check lens is set to F stop 11 (change by manually adjusting lens aperture ring) Check Infrared (IR) Absorbing

More information

Use of the HSW5 Spinning Disk Confocal Microscope Updated last May 25, 2010 OK

Use of the HSW5 Spinning Disk Confocal Microscope Updated last May 25, 2010 OK Use of the HSW5 Spinning Disk Confocal Microscope Updated last May 25, 2010 OK Getting Started: 2 Starting Micromanager and Loading a Configuration 3 The Main Micromanager GUI 3 Configuration Settings

More information

User Manual for HoloStudio M4 2.5 with HoloMonitor M4. Phase Holographic Imaging

User Manual for HoloStudio M4 2.5 with HoloMonitor M4. Phase Holographic Imaging User Manual for HoloStudio M4 2.5 with HoloMonitor M4 Phase Holographic Imaging 1 2 HoloStudio M4 2.5 Software instruction manual 2013 Phase Holographic Imaging AB 3 Contact us: Phase Holographic Imaging

More information

Everest System / Slidebook Operating Procedures

Everest System / Slidebook Operating Procedures Everest System / Slidebook Operating Procedures NOTICE: This guide is meant to supplement training, not replace it. All users must be trained first hand by a core employee. Training of others in your lab

More information

Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope

Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope ZEN 2009 Optical Imaging & Vital Microscopy Core Baylor College of Medicine (2017) Power ON Routine 1 2 Turn Chameleon TiS laser key from Standby

More information

b. Turn the power switch and key to on position for blue laser.

b. Turn the power switch and key to on position for blue laser. OLYMPUS FLUOVIEW 300 CONFOCAL MICOSCOPE OPERATION PROCEDURE 1. Turn ON microscope in this order: 1) Turn on mercury lamp (Note: once the mercury lamp is turned off, DO NOT turn it back on for at least

More information

KoPa Scanner. User's Manual A99. Ver 1.0. SHENZHEN OSTEC OPTO-ELECTRONIC TECHNOLOGY CO.,LTD.

KoPa Scanner. User's Manual A99. Ver 1.0. SHENZHEN OSTEC OPTO-ELECTRONIC TECHNOLOGY CO.,LTD. KoPa Scanner A99 User's Manual Ver 1.0 SHENZHEN OSTEC OPTO-ELECTRONIC TECHNOLOGY CO.,LTD. http://www.ostec.com.cn Content Chapter 1 Start... 1 1.1 Safety Warnings and Precautions... 1 1.2 Installation

More information

Guide to Confocal 5. Starting session

Guide to Confocal 5. Starting session Guide to Confocal 5 Remember that when booking and before starting session you can check for any problems at https://www.bris.ac.uk/biochemistry/uobonly/cif/index.html Starting session Switch on microscope

More information