pco.1300 solar cooled digital 12bit CCD camera system
|
|
- Dustin Freeman
- 6 years ago
- Views:
Transcription
1 pco.1300 solar cooled digital 12bit CCD camera system designed for electroluminescence (EL) applications quantum efficiency of up to nm superior low noise of typ. 6 e - 10 MHz resolution of 1392 x 1040 pixel cooling of -25 C vs. ambient optimal offset stability and control (< 1 count/h) 12 bit dynamic range exposure times range from 5 μs - 1 h standard IEEE 1394a ( Firewire ) interface free software camware and software development kit included
2 pco.1300 solar This versatile high performance 12 bit CCD camera system is specifically designed for electroluminescence (EL) applications in the range of 850 nm to 1200 nm. The pco.1300 solar has an extraordinary quantum efficiency (QE) of up to nm. In addition a proprietary offset control algorithm has been developed which provides very high offset stability (drift 1 count/h), regardless of ambient temperature or signal changes ensuring accurate and repeatable quantitative data over long periods of time. The pco.1300 solar s most unique features are its increased sensitivity in the NIR range of the spectrum and the no glow functionality. Binning and cooling can be selected to accomodate the user s application. Camera features excellent resolution (1392 x 1040 pixel), 12 bit dynamic range, exposure times from 5 µs to 1 hour, internal frame buffer for continuous image capture (64 MB min), excellent low noise of 6 e - 10 MHz, cooling of -25 C vs. ambient, standard interface IEEE1394a ( Firewire ). technical data unit setpoint pco.1300 solar resolution (hor x ver) 1 extended mode x 1060 pixel size (hor x ver) µm² sensor format / diagonal inch / mm 2/3 / quantum efficiency 880 nm + 15 C 13 full well capacity e dark current e - /pixel + 10 C standard mode 0.05 image sensor maximum dynamic range db CCD + 10 MHz ICX285AL dynamic range A/D 2 bit readout noise e - 10 / 20 MHz 6 / 10 imaging frequency, frame rate full 10 / 20 MHz 5.9 / 11.7 pixel scan rate MHz 10 / 20 A/D conversion factor e - / count standard / IR boost 3.8 / 1.9 spectral range nm normal exposure time standard IR boost mode 5 µs.. 1 h 100 ms.. 1 h
3 technical data unit setpoint pco.1300 solar anti-blooming stand.light mode IR boost 100 ms expos. time > 400 / > 4 smear % < binning (hor x ver) pixel 1 x 1, 1 x 2, 2 x 1, 2 x 2 optical input [1] horizontal versus vertical [2] Analog-to-Digital-converter c-mount trigger, auxiliary signals internal / external software / TTL level power supply cooling method cooled CCD temperature VDC typical C versus ambient temperature V 24 V 1 stage Peltier cooler with forced air cooling power consumption W max. 20 mechanical dimensions (w x h x l) -25 mm³ 113 x 104 x 110 weight kg 1.1 ambient temperature C range operating humidity % range storage temperature C range data interface quantum efficiency IEEE 1394a (measured by pco at -10 C)
4 The pco.1300 solar was operated at different CCD image sensor temperatures and a homogeneous light signal was measured. The measurement was repeated at different peak wavelengths of the light. The mean signal normalized to the 5 C value is displayed with respect to the temperature. areas of application solar cell in-line quality control solar panel quality control low light level imaging machine vision and industrial applications scientific imaging Red and NIR fluorescence applications spectroscopy examples of applications Electroluminescence images of solar panels with poly-crystalline (upper photo) and monocrystalline (lower photo) solar cells. Darker areas indicate areas or chrystal layers, which do not contribute to the solar current generation....with friendly permission of: pro Terra, Regenerative Power Engineering, Memmingen,
5 Image of a mono-crystalline solar cell, which is operated under forward bias condition. The electroluminescence (EL) of the cell below the bus bar and the grid electrodes is clearly visible. The image was recorded by a pco.1300 solar at 2s exposure time. The darker areas indicate areas of minor quality within the solar cell....measured by pco contact The Cooke Corporation PCO AG 6930 Metroplex Drive Donaupark 11 Romulus, Michigan Kelheim, Germany USA tel fon +49 (0) fax fax +49 (0) info@cookecorp.com info@pco.de pco.1300 solar product sheet 07/2009 subject to changes without prior notice PCO AG, Kelheim
pco.1600 cooled digital 14bit CCD camera system
pco.1600 cooled digital 14bit CCD camera system n excellent resolution (1600 1200 pixel) n 14 bit dynamic range n frame rate of 30 fps at full resolution n image memory in camera (camram up to 4 GB) n
More informationsensicam em electron multiplication digital 12bit CCD camera system
sensicam em electron multiplication digital 12bit CCD camera system electron multiplication gain of up to 1000 superior resolution (1004 1002 pixel) for EMCCD extremely low noise < 1e excellent quantum
More informationsensicam qe cooled digital 12bit CCD camera system
sensicam qe cooled digital 12bit CCD camera system super quantum efficiency up to 65% extremely low noise, down to 4e - rms 12bit dynamic range thermo-electrical cooling (Peltier) down to -12 C high resolution
More informationpco.dimax digital high speed 12 bit CMOS camera system
dimax digital high speed 12 bit CMOS camera system 1279 fps @ full resolution 2016 x 2016 pixel 12 bit dynamic range 4502 fps @ 1008 x 1000 pixel color & monochrome image sensor versions available exposure
More informationhsfc pro 12 bit ultra speed intensified imaging
hsfc pro 12 bit ultra speed intensified imaging four MCP image intensifier camera modules ultra fast shutter down to 3 ns in single mode excellent sensitivity of the system allows single photon detection
More information: fps. pco.edge. 1.4 electrons. 5.5 megapixel. pco. high speed. high resolution. low noise. high dynamic range. scientific CMOS camera
edge scientific CMOS camera low noise 1.4 electrons high resolution 5.5 megapixel high speed high dynamic range 22 000 :1 100 fps The new edge is a breakthrough in scientific imaging cameras, due to its
More informationpanda family ultra compact scmos cameras
panda family ultra compact scmos cameras up to 95 % quantum efficiency 6.5 µm pixel size for a perfect fit in microscopy and life science applications 65 mm ultra compact design specifications panda family
More informationedge 4.2 bi cooled scmos camera
edge 4.2 cooled scmos camera illuminated up to 95% quantum efficiency deep cooled down to -25 C compact design resolution 2048 x 2048 pixel with 6.5 µm pixel size illuminated scmos sensor selectable input
More informationpco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps : 1 > 70 % pco. low noise high resolution high speed high dynamic range
edge 4.2 LT scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.8 electrons USB 3.0 small form factor high dynamic range 36 000 : 1 high speed 40 fps high quantum efficiency > 70 % edge
More informationproduct overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology
product overview family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology scmos knowledge base scmos General Information PCO scmos cameras are a breakthrough
More informationpco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range
edge 4.2 LT scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.8 electrons USB 3.0 small form factor high dynamic range up to 37 500:1 high speed 40 fps high quantum efficiency up to
More informationpco.edge electrons 2048 x 1536 pixel 50 fps :1 > 60 % pco. low noise high resolution high speed high dynamic range
edge 3.1 scientific CMOS camera high resolution 2048 x 1536 pixel low noise 1.1 electrons global shutter USB 3.0 small form factor high dynamic range 27 000:1 high speed 50 fps high quantum efficiency
More informationpco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range
edge 4.2 LT scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.8 electrons USB 3.0 small form factor high dynamic range up to 37 500:1 high speed 40 fps high quantum efficiency up to
More informationpco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps :1 > 70 % pco. low noise high resolution high speed high dynamic range
edge 4.2 LT scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.8 electrons USB 3.0 small form factor high dynamic range 37 500:1 high speed 40 fps high quantum efficiency > 70 % edge
More informationpco.edge electrons 2048 x 2048 pixel 100 fps :1 > 70 % pco. low noise high resolution high speed high dynamic range
edge 4.2 scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.9 electrons USB 3.0 Camera Link high dynamic range 33 000:1 high quantum efficiency > 70 % high speed 100 fps edge 4.2 scientific
More information1469 fps. pco.dimax HD / HD+ ISO speed. color fidelity. HD 1920 x 1080 pixel HD x 1440 pixel. pco. high speed. excellent high.
dimax HD / HD+ high speed CMOS camera excellent high color fidelity high resolution HD 1920 x 1080 pixel HD+ 1920 x 1440 pixel ISO speed high speed 1469 fps The new dimax HD is a breakthrough in high speed
More informationpco.edge electrons 2560 x 2160 pixel 100 fps :1 > 60 % pco. low noise high resolution high speed high dynamic range
edge 5.5 scientific CMOS camera high resolution 2560 x 2160 pixel low noise 1.0 electrons lightsheet scanning mode USB 3.0 Camera Link small form factor high dynamic range 30 000:1 high speed 100 fps high
More informationDigital Cameras for Microscopy
Digital Cameras for Microscopy Fast frame rate and high sensitivity EM-CCD (Electron multiplication CCD) cameras High dynamic range Enhanced Ideal format for short exposures, fast frame rate and high dynamic
More informationpco.edge electrons 2560 x 2160 pixel 100 fps :1 > 60 % pco. low noise high resolution high speed high dynamic range
edge 5.5 scientific CMOS camera high resolution 2560 x 2160 pixel low noise 1.0 electrons lightsheet option USB 3.0 Camera Link high dynamic range 30 000:1 high speed 100 fps high quantum efficiency >
More informationpco.edge gold electrons 2048 x 2048 pixel -30 Celsius :1 > 70 % pco. low noise high resolution cooling down to high dynamic range
edge gold 4.2 deep cooled scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.8 electrons deep cooled small form factor high dynamic range 37 500:1 high quantum efficiency > 70 % cooling
More informationpco.dimax HS light sensitivity pco. high speed > Mpixel excellent
dimax HS high speed CMOS cameras excellent light sensitivity high speed > 7000 fps @ 1 Mpixel high resolution 1000 x 1000 pixel HS1 1400 x 1050 pixel HS2 2000 x 2000 pixel HS4 dimax HS high speed CMOS
More informationpco.edge electrons 2048 x 2048 pixel 100 fps :1 up to 82 % pco. low noise high resolution high speed high dynamic range
edge 4.2 scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.8 electrons lightsheet scanning mode USB 3.0 Camera Link small form factor high dynamic range 37 500:1 high speed 100 fps high
More informationMinimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.
Now Powered by LightField PyLoN:2K 2048 x 512 The PyLoN :2K is a controllerless, cryogenically-cooled CCD camera designed for quantitative scientific spectroscopy applications demanding the highest possible
More informationDV420 SPECTROSCOPY. issue 2 rev 1 page 1 of 5m. associated with LN2
SPECTROSCOPY Andor s DV420 CCD cameras offer the best price/performance for a wide range of spectroscopy applications. The 1024 x 256 array with 26µm 2 pixels offers the best dynamic range versus resolution.
More informationpco.edge electrons 2048 x 2048 pixel 100 fps :1 up to 82 % pco. low noise high resolution high speed high dynamic range
edge 4.2 scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.8 electrons lightsheet scanning mode USB 3.0 Camera Link small form factor high dynamic range 37 500:1 high speed 100 fps high
More information100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.
Now Powered by LightField PIXIS: 1 134 x 1 The PIXIS series from Princeton Instruments (PI) are fully integrated, low noise cameras with a 134 pixel format designed for quantitative scientific optical
More informationZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View
Product Information Version 1.0 ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View ZEISS Axiocam 503 color Sensor Model
More informationpco.dimax HD / HD+ ISO speed color fidelity pco. excellent highest high speed Full HD
dimax HD / HD+ high speed CMOS cameras highest color fidelity excellent ISO speed high speed 2 128 fps @ Full HD high resolution 1920 x 1080 pixel HD 1920 x 1440 pixel HD+ features dimax HD high speed
More informationSpecifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -
Apogee Alta Series System Features 1 High Resolution Sensor 1.0 Megapixel sensor with 13 mm pixels delivers a large field of view with high resolution. Programmable TE cooling down to 50 o C below ambient
More informationZEISS Axiocam 512 color Your 12 Megapixel Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution
Product Information Version 1.0 ZEISS Axiocam 512 color Your 12 Megapixel Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution ZEISS Axiocam 512 color Sensor Model
More informationFluorescence (Luminescence) Lifetime Imaging application simplified... with the pco.flim
Fluorescence (Luminescence) Lifetime Imaging application simplified... with the pco.flim lifetimes from 100 ps to 100 µs unique resolution 1008 x 1008 pixels high frame rate up to 90 fps frequency synthesizer
More informationABOUT RESOLUTION. pco.knowledge base
The resolution of an image sensor describes the total number of pixel which can be used to detect an image. From the standpoint of the image sensor it is sufficient to count the number and describe it
More informationApplications for cameras with CMOS-, CCD- and InGaAssensors. Jürgen Bretschneider AVT, 2014
Applications for cameras with CMOS-, CCD- and InGaAssensors Jürgen Bretschneider AVT, 2014 Allied Vision Technologies Profile Foundation: 1989,Headquarters: Stadtroda (Thüringen), Employees: aprox. 265
More informationOptional AR coating and wedge windows are available
TThe PIXIS series from Princeton Instruments (PI) are fully integrated, low noise cameras designed for quantitative scientific imaging optical spectroscopy applications. Designed utilizing PI s exclusive
More informationIT FR R TDI CCD Image Sensor
4k x 4k CCD sensor 4150 User manual v1.0 dtd. August 31, 2015 IT FR 08192 00 R TDI CCD Image Sensor Description: With the IT FR 08192 00 R sensor ANDANTA GmbH builds on and expands its line of proprietary
More informationMinimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available.
SOPHIA: 2048B The SOPHIA : 2048B camera from Princeton Instruments (PI) is fully integrated, ultra-low noise 2048 x 2048, 15 µm pixel CCD camera designed expressly for the most demanding quantitative scientific
More informationUpgrade to Andor s high-resolution Luca EM R EMCCD; the new price/performance benchmark.
Features & benefits EMCCD Technology Ultimate in sensitivity from EMCCD gain. Even single photons are amplified above the noise. Full QE of the sensor is harnessed (visit www.emccd.com) Megapixel sensor
More informationDU-897 (back illuminated)
IMAGING Andor s ixon EM + DU-897 back illuminated EMCCD has single photon detection capability without an image intensifier, combined with greater than 90% QE of a back-illuminated sensor. Containing a
More informationAxioCam MRc 5 A World of Digital Possibilities
Microscopy from Carl Zeiss AxioCam MRc 5 A World of Digital Possibilities More flexibility and more performance in microscope camera technology Impressive Performance A trend setter in digital microscopy,
More informationSpecifications Summary. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode. Maximum spectra per sec 1,612
100 90 80 70 60 BU2 BU BV BRDD Spectroscopy QE (%) 50 40 FI 30 20 10 OE UV 0 200 300 400 500 600 700 800 900 1000 1100 1200 Wavelength (nm) Features and Benefits MultiMegahertz Readout High repetition
More informationBaumer TXF50 Art. No: OD107988
Digital Monochrome (b/w) Progressive Scan Camera System: IEEE1394b Baumer TXF50 Art. No: OD107988 FireWire TM IEEE1394b (800 Mbit / sec) progressive scan CCD-camera 2448 x 2050 pixel Up to 15 full frames
More informationCompatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.
NIRvana: 640LN The NIRvana: 640LN from Princeton Instruments is a scientific-grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy applications. The camera
More informationMultispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2
Multispectral imaging device Most accurate homogeneity MeasureMent of spectral radiance UMasterMS1 & UMasterMS2 ADVANCED LIGHT ANALYSIS by UMaster Ms Multispectral Imaging Device UMaster MS Description
More informationQE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers
QE65000 Spectrometer Scientific-Grade Spectroscopy in a Small Footprint QE65000 The QE65000 Spectrometer is the most sensitive spectrometer we ve developed. Its Hamamatsu FFT-CCD detector provides 90%
More informationLast class. This class. CCDs Fancy CCDs. Camera specs scmos
CCDs and scmos Last class CCDs Fancy CCDs This class Camera specs scmos Fancy CCD cameras: -Back thinned -> higher QE -Unexposed chip -> frame transfer -Electron multiplying -> higher SNR -Fancy ADC ->
More informationBack-illuminated scientific CMOS camera. Datasheet
Back-illuminated scientific CMOS camera Datasheet Breakthrough Technology KURO DATASHEET Highlights The KURO from Princeton Instruments is the world s first scientific CMOS (scmos) camera system to implement
More informationX-Ray diffraction pattern of the Synchrotron Soleil,France. Courtesy of Vincent Jacques. Direct Detection X-Ray Imaging. Specifications Summary
X-Ray diffraction pattern of the Synchrotron Soleil,France. Courtesy of Vincent Jacques Low Light Imaging X-Ray Cameras Features and Benefits Open front end 1 CF152 flange and knife-edge sealing provided
More informationGigE MV Cameras - XCG
GigE MV Cameras - XCG Gig-E Camera Line-Up - XCG Speed EXview HAD High IR sensitive ICX-625 (Super HAD) ICX-274 (Super HAD) ICX-285 (EXView HAD) ICX-424 (HAD) XCG-V60E B&W, 1/3 VGA, 90fps XCG-SX97E SX99E
More informationData Sheet SMX-160 Series USB2.0 Cameras
Data Sheet SMX-160 Series USB2.0 Cameras SMX-160 Series USB2.0 Cameras Data Sheet Revision 3.0 Copyright 2001-2010 Sumix Corporation 4005 Avenida de la Plata, Suite 201 Oceanside, CA, 92056 Tel.: (877)233-3385;
More informationBaumer FWX05c-II NeuroCheck Edition
Digital Color Progressive Scan Camera System: IEEE1394a Baumer FWX05c-II NeuroCheck Edition Art. No.: OD106154 IEEE1394a (FireWire TM ) Progressive Scan CCD Camera 780 x 582 Pixels Outstanding Color Fidelity
More informationHigh Resolution BSI Scientific CMOS
CMOS, EMCCD AND CCD CAMERAS FOR LIFE SCIENCES High Resolution BSI Scientific CMOS Prime BSI delivers the perfect balance between high resolution imaging and sensitivity with an optimized pixel design and
More informationMOTICAMPRO PROFESSIONAL CCD MICROSCOPY CAMERAS
MOTICAMPRO PROFESSIONAL CCD MICROSCOPY CAMERAS 2 MOTICAMPRO The Moticam PRO series contains 12 models with different SONY ICX sensor resolutions and technical characteristics, providing users with a wide
More informationLightning-Cam TM Camera
Lightning-Cam TM Camera High Performance Scientific CMOS Camera The sensitivity of EMCCDs with the resolution of CCDs www.easyratiopro.com The new Lightning-Cam camera is a breakthrough in scientific imaging
More informationPIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels Direct detection
PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels Direct detection The PIXIS-XO series of fully integrated imaging cameras utilizes back-illuminated (BI) and back-illuminated, deepdepletion (BR)
More informationThe new CMOS Tracking Camera used at the Zimmerwald Observatory
13-0421 The new CMOS Tracking Camera used at the Zimmerwald Observatory M. Ploner, P. Lauber, M. Prohaska, P. Schlatter, J. Utzinger, T. Schildknecht, A. Jaeggi Astronomical Institute, University of Bern,
More informationikon-m 934 DO Series
X-Ray diffraction pattern of the Synchrotron Soleil,France. Courtesy of Vincent Jacques Low Light Imaging X-Ray Cameras Features and Benefits Open front end 1 CF152 flange and knife-edge sealing provided
More informationTechnical note EM-CCD CAMERA. 1. Introduction
EM-CCD CAMERA Technical note 1. Introduction 2. Technologies of cooled CCD cameras 2.1 Hermetic vacuum-sealed chamber 2.2 Advantages of an Interline Transfer CCD (ER-150 CCD) 2.3 Readout noise 2.4 Dark
More informationQHYCCD New Product Announcement
QHYCCD New 1 QHY128C 35mm Format 24 Megapixels QHY367C 35mm Format 36 Megapixels Ultra High Performance Ultra Low Read Noise and Dark Current Unique Thermal Noise Reduction Technology Zero Amplifier Glow
More informationAugust 14, SOFTHARD Technology Ltd. Lesna 52, Marianka Slovak Republic
August 14, 2009 SOFTHARD Technology Ltd Lesna 52, 900 33 Marianka Slovak Republic http://www.softhard.sk 1 Table of Contents 1 Table of Contents... 2 2 Revision History... 3 3 Disclaimers... 4 4 Privacy
More informationTEM Cameras. Digital Cameras for Electron Microscopy
Digital Imaging Solutions TEM Cameras Side- and bottom-mounted TEM cameras Digital Cameras for Electron Microscopy IMAGING SOLUTIONS FOR ELECTRON MICROSCOPY. BASED ON OPTO-DIGITAL KNOW-HOW. DESIGNED BY
More informationSOFTHARD Technology Ltd.
SOFTHARD Technology Ltd. June 19, 2008 SOFTHARD Technology Ltd Lesna 52, 900 33 Marianka Slovak Republic http://www.softhard.sk 1 Table of Contents 1 Table of Contents... 2 2 Revision History... 3 3 Disclaimers...
More informationSOLAR CELL INSPECTION WITH RAPTOR PHOTONICS OWL (SWIR) AND FALCON (EMCCD)
Technical Note Solar Cell Inspection SOLAR CELL INSPECTION WITH RAPTOR PHOTONICS OWL (SWIR) AND FALCON (EMCCD) August 2012, Northern Ireland Solar cell inspection relies on imaging the photoluminescence
More informationBasler. Line Scan Cameras
Basler Line Scan Cameras Next generation CMOS dual line scan technology Up to 140 khz at 2k or 4k resolution, up to 70 khz at 8k resolution Color line scan with 70 khz at 4k resolution High sensitivity
More informationAxioCam HR Success Through Performance
Microscopy from Carl Zeiss AxioCam HR Success Through Performance The high-resolution camera for digital documentation Superior performance for research and routine work brilliant quality documentation
More informationProsilica GT 1930L Megapixel machine vision camera with Sony IMX CMOS sensor. Benefits and features: Options:
Prosilica GT 1930L Versatile temperature range for extreme environments IEEE 1588 PTP Power over Ethernet EF lens control 2.35 Megapixel machine vision camera with Sony IMX CMOS sensor Prosilica GT1930L
More informationSoft X-rays Hard X-rays. Specifications Summary. Active pixels 1024 x Pixel size (W x H) 13 x 13 µm
Photon Energy 10eV 100eV 1keV 10keV 100keV Soft X-rays Hard X-rays YEA VACUUM WAANTY High Energy Detection Features and Benefits Standalone Beryllium window 1 200 µm thick Beryllium foil window as standard
More informationUV-NIR LASER BEAM PROFILER
CinCam CCD Technical Data CCD1201 CCD1301 CCD2301 CCD2302 Standard Series Standard Series Standard Series Standard Series SENSOR DATA Format: 1/2 1/3 2/3 2/3 Active area (without cover glass): 6.5mm x
More informationMako G G-030. Compact machine vision camera with high frame rate. Benefits and features: Options:
Mako G G-030 CMOSIS/ams CMOS sensor Piecewise Linear HDR feature High Frame rate Ultra-compact design Compact machine vision camera with high frame rate Mako G-030 is a 0.3 megapixel GigE machine vision
More informationPIXIS-XO: 1024B 1024 x 1024 imaging array 13 x 13 µm pixels
The PIXIS-XO series of fully integrated imaging cameras utilizes back-illuminated and back-illuminated deep depletion CCDs without AR coating, for direct detection of the widest range of X-rays between
More informationCamera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note
Technical Note CMOS, EMCCD AND CCD CAMERAS FOR LIFE SCIENCES Camera Test Protocol Introduction The detector is one of the most important components of any microscope system. Accurate detector readings
More information30 x 3.8 mm / 2000 x 256 pixel NIR Spectroscopy CCD. cooling. Specifications Summary. Active pixels 2000 x 256
Quantum efficiency (%) 1 9 8 7 6 5 4 3 Absorption Photoluminescence 532 nm Raman New Low Noise Back-illuminated Deep-Depletion Technology Spectroscopy 633 nm Raman 2 785 nm Raman 1 83 nm Raman 2 3 4 5
More informationReal-color High Sensitivity Scientific Camera
Real-color High Sensitivity Scientific Camera For the first time with true color The Best Choice for Both Brightfield and Fluorescence Imaging Hi-SPEED CERTIFIED 6.5μm x 6.5μm pixel scmos color sensor
More informationLASU - Laser Applied Stimulation & Uncaging
Built with neuroscience in mind Optogenetics & Uncaging 1 LASU - Laser Applied Stimulation & Uncaging Optogenetics & Uncaging www.scientifica.uk.com/lasu www.scientifica.uk.com 2 LASU - Laser Applied Stimulation
More information(PT-3528) Chip Ambient Light Sensor, RoHS Compliant. Token Electronics Industry Co., Ltd. Version: July 26, Web:
Version: July 26, 2017 (PT-3528) Chip Ambient Light Sensor, RoHS Compliant Token Electronics Industry Co., Ltd. Web: www.token.com.tw Email: rfq@token.com.tw Taiwan: No.137, Sec. 1, Zhongxing Rd., Wugu
More informationReal-color High Sensitivity Scientific Camera. For the first time with true color ISO9001
Real-color High Sensitivity Scientific Camera For the first time with true color ISO9001 The Best Choice for Both Brightfield and Fluorescence Imaging Hi-SPEED CERTIFIED 6.5μm x 6.5μm pixel scmos color
More informationOEM Low Cost CCD Cameras
OEM Low Cost OEM Imaging Solutions Apogee is a proven supplier of OEM imaging solutions. We can provide a modified version of any of our standard models or a completely new design to your requirements.
More informationSuperior ICP-OES optical design for unmatched speed and performance
Superior ICP-OES optical design for unmatched speed and performance Technical Overview 5110 ICP-OES Introduction The Agilent 5110 ICP-OES combines a vertical torch, unique dual view and synchronous dual
More informationWHITE PAPER. Sensor Comparison: Are All IMXs Equal? Contents. 1. The sensors in the Pregius series
WHITE PAPER www.baslerweb.com Comparison: Are All IMXs Equal? There have been many reports about the Sony Pregius sensors in recent months. The goal of this White Paper is to show what lies behind the
More informationSpectroscopy at Pace. Specifications Summary. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode
NEW NOW AVAILABLE WITH Dual AR EXTENDED RANGE TECHNOLOGY Spectroscopy Features and Benefits Peak QE up to 95% Visibleoptimized BV & infraredoptimized BRDD model Extended range dualar option 90% QE and
More informationInstruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers
Aalto University School of Electrical Engineering Metrology Research Institute Hans Baumgartner Instruction manual for Version 1.0 24/11/2016 Page 2 (9) 1. Table of contents 1. Table of contents... 2 2.
More informatione2v Launches New Onyx 1.3M for Premium Performance in Low Light Conditions
e2v Launches New Onyx 1.3M for Premium Performance in Low Light Conditions e2v s Onyx family of image sensors is designed for the most demanding outdoor camera and industrial machine vision applications,
More informationThe Condor 1 Foveon. Benefits Less artifacts More color detail Sharper around the edges Light weight solution
Applications For high quality color images Color measurement in Printing Textiles 3D Measurements Microscopy imaging Unique wavelength measurement Benefits Less artifacts More color detail Sharper around
More informationDifferences Between the A101f/fc and the A102f/fc
Differences Between the A101f/fc and the A102f/fc Version 1.1, October 13, 2003 Introduction Basler is introducing a new megapixel camera family at the Vision Show 2003 (October 21-23). As you know, the
More information400BSI V2.0. BSI Scientific CMOS Cooled Camera. 4 0 fps. 7 4 fps. 1.2 e % PRNU. 0.2 e μm 4.2 MP.
4BSI V2. BSI Scientific CMOS Cooled Camera 1 QExFF (%) 8 6 4 2 2 4 6 8 1 11 Wavelength(nm) 7 4 fps CameraLink Faster Capture 4 fps USB3..2 e - DSNU.3 % PRNU More Accurate 1.2 e - Read Noise 6.5 μm Pixel
More informationBaySpec SuperGamut OEM
BaySpec SuperGamut OEM Spectrographs & Spectrometers RUGGED SOLID STATE HIGH RESOLUTION OPTIMIZED COOLING COST EFFECTIVE HIGH THROUGHPUT www.bayspec.com Specifications Model UV-NIR VIS-NIR NIR 900-1700nm
More informationIntegrated Multi-Aperture Imaging
Integrated Multi-Aperture Imaging Keith Fife, Abbas El Gamal, Philip Wong Department of Electrical Engineering, Stanford University, Stanford, CA 94305 1 Camera History 2 Camera History Despite progress,
More informationThe CCD-S3600-D(-UV) is a
Advanced Digital High-Speed CCD Line Camera CCD-S3600-D(-UV) High-Sensitivity Linear CCD Array with 3648 Pixels, 16-bit ADC, 32 MB DDR2 RAM, USB 2.0, Trigger Input & Output USB 2.0 Plug & Play The CCD-S3600-D(-UV)
More informationNEW. Spectroscopy at Pace. Specifications Summary 1. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode
Quantum efficiency (%) 100 90 80 70 60 50 40 30 BU BV, BVF FI BU2 BRDD BEX2DD NEW NOW AVAILABLE WITH Antifringing BACK THINNED & TECHNOLOGY Dual AR EXTENDED RANGE Spectroscopy 20 10 OE UV 0 200 300 400
More informationCCD30-11 NIMO Back Illuminated Deep Depleted High Performance CCD Sensor
CCD30-11 NIMO Back Illuminated Deep Depleted High Performance CCD Sensor FEATURES 1024 by 256 Pixel Format 26µm Square Pixels Image area 26.6 x 6.7mm Back Illuminated format for high quantum efficiency
More informationCCD1600A Full Frame CCD Image Sensor x Element Image Area
- 1 - General Description CCD1600A Full Frame CCD Image Sensor 10560 x 10560 Element Image Area General Description The CCD1600 is a 10560 x 10560 image element solid state Charge Coupled Device (CCD)
More informationidus 420 Series Specifications Summary 2 Register well depth (typical) 1,000,000 e - Maximum spectra per sec 88 Read noise As low as 4 e -
Quantum efficiency (%) 90 80 70 60 50 40 30 BU NEW NOW AVAILABLE WITH BU2 BRDD BEX2DD Antifringing BACK THINNED & TECHNOLOGY Dual AR EXTENDED RANGE Spectroscopy 0 0 300 400 500 600 700 800 900 0 1 10 Wavelength
More informationUNiiQA+ Color CL CMOS COLOR CAMERA
UNiiQA+ Color CL CMOS COLOR CAMERA Datasheet Features CMOS Color LineScan Sensors: 4096 pixels, 5x5µm 2048, 1024 or 512 pixels, 10x10µm Interface : CameraLink (Base or Medium) Line Rate : Up to 40 kl/s
More informationUSB components. Multi-Sensor Cameras. Camera Configuration. Available Sensor Board Designs. Options. Base unit and sensor boards
Multi- Cameras Base unit and sensor boards Up to four pixel-synchronous sensors connected to the base unit by flex-foil cable (LVDS data transfer) Free positioning of the external sensors Plug and play
More informationCooled cameras for scientific applications and astronomy. Ian Alderton Alrad Imaging division of Alrad Instruments Ltd
Cooled cameras for scientific applications and astronomy Ian Alderton Alrad Imaging division of Alrad Instruments Ltd www.alrad.co.uk History 1970 - started as Wenzel Elektronic UK in NIM modules and radiation
More informationUltra-high resolution 14,400 pixel trilinear color image sensor
Ultra-high resolution 14,400 pixel trilinear color image sensor Thomas Carducci, Antonio Ciccarelli, Brent Kecskemety Microelectronics Technology Division Eastman Kodak Company, Rochester, New York 14650-2008
More informationSection lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS
Section lll: SM Series ometers SPECTROMETERS SM200 OEM Packaged Fiber Optic CCD SM240 Hand-Held CCD SM241 Near Infrared Enhanced CCD AD300 Back Thinned CCD Tunable, TE Cooled SM300 Fluorencenced/Raman
More informationSpectrolab in Optical Microscopy USB Digital Cameras CAT WCAM Series WIFI Camera
Spectrolab in Optical Microscopy USB Digital Cameras CAT 701110 WCAM Series WIFI Camera 1 Product Description The T-Tek WCAM series camera is a C-mount digital camera that attaches to the eyepiece of a
More informationTHE TUNABLE LASER LIGHT SOURCE C-WAVE. HÜBNER Photonics Coherence Matters.
THE TUNABLE LASER LIGHT SOURCE HÜBNER Photonics Coherence Matters. FLEXIBILITY WITH PRECISION is the tunable laser light source for continuous-wave (cw) emission in the visible and near-infrared wavelength
More informationDescription. TC247SPD-B0 680 x 500 PIXEL IMPACTRON TM MONOCHROME CCD IMAGE SENSOR SOCS091 - DECEMBER REVISED MARCH 2005
Very Low Noise, Very High Sensitivity, Electronically Variable Charge Domain Gain 1/2-in Format, Solid State Charge-Coupled Device (CCD) Frame Interline Transfer Monochrome Image Sensor for Low Light Level
More information