SIM University Projector Specifications. Stuart Nicholson System Architect. May 9, 2012
|
|
- Roderick Lawson
- 6 years ago
- Views:
Transcription
1 2012
2 2012 Projector Specifications 2 Stuart Nicholson System Architect
3 System Specification Space Constraints System Contrast Screen Parameters System Configuration Many interactions Projector Count Resolution Mission Type Feature Discrimination Maintenance Schedule IG Hardware Realism Database Gamut 3
4 System Specification Space Constraints System Contrast Screen Parameters System Configuration Many interactions Translation to projector specification is not obvious Projector Count Resolution Mission Type Feature Discrimination Maintenance Schedule IG Hardware Realism Database Gamut 4
5 System Specification Space Constraints System Contrast Screen Parameters System Configuration Many interactions Translation to projector specification is not obvious Will discuss interactions with projector specifications Projector Count Resolution MTF Color Error Lens Type Uniformity Modulators Pixel Size Feature Discrimination Illuminator Type Contrast Maintenance Schedule Lens Offset Brightness Color Gamut Throw Ratio Smear Reduction Frame Rate Image Geometry tin tout Latency IG Hardware Mission Type Realism Database Gamut 5
6 Interactions Between Projector Parameters Color Error Lens Type Uniformity Contrast Lens Offset Throw Ratio Image Geometry MTF Brightness Smear Reduction tin Latency tout Frame Rate Pixel Size Modulators Color Gamut Illuminator Type 6
7 Interactions Between Projector Parameters Contrast Uniformity Brightness Smear Reduction tin Latency tout 7
8 Brightness Interactions Technology choices Illuminator type Pixel size Design choices Contrast Uniformity System choices Color gamut, white point Lens type Smear reduction Lens shift 8
9 Brightness Interactions Technology / Design Technology choices Illuminator type Illuminator type Pixel size Design choices Contrast Uniformity System choices Color gamut, white point Lens type Smear reduction Lens shift Available raw lumens Lifetime Cost Physical and optics size Pixel size Resolution vs optics size Contrast and uniformity Apertures limit brightness Increasing uniformity reduces brightness 9
10 Brightness Interactions System Technology choices Color gamut Illuminator type Pixel size Design choices Contrast Uniformity System choices Color gamut, white point Lens type Smear reduction Lens shift Color saturation Brightness profile over gamut Lens type Apertures in lens for contrast and depth of field Throw ratio Smear reduction Hold time (display time) Lens shift Apertures in lens 10
11 Brightness vs Color y=7000 y=231 y=250 y=273 y=300 y=333 y=375 y=429 y=500 y=600 y=750 y=1000 y=1500 y=
12 Brightness Measurement System parameters Color gamut Frame rate Smear reduction Instrument Define Measurement / Technique White flat field Color checkerboard Center, 9-pt, 13-pt 12
13 Contrast Technology choices Pixel size Design choices Brightness Uniformity System choices Lens type Throw ratio Lens shift 13
14 Contrast Interactions Technology / Design Technology choices Pixel size Design choices Brightness Uniformity System choices Lens type Throw ratio Lens shift Cost Physical and optics size Pixel size Resolution vs optics size Brightness and uniformity Apertures improve contrast Increasing uniformity reduces contrast 14
15 Contrast Interactions System Technology choices Lens type Pixel size Design choices Brightness Uniformity System choices Lens type Throw ratio Lens shift Lenses with shift capability may increase spill light Apertures in lens improve contrast Throw ratio and lens shift Contrast can vary with throw ratio and lens shift due to changing effectiveness of apertures in lens (throw) and system (shift) 15
16 Contrast Measurement System parameters K1 W1 K2 W2 Typically specified at zero lens shift W3 K3 W4 K4 Instrument Define Measurement / Technique K5 W7 W5 K7 K6 W7 W6 K8 Flat-field (sequential) ANSI checkerboard Spill 16
17 Latency 17
18 Latency Smear reduction (reduction of hold or display time) can reduce latency Increasing frame rate can significantly reduce latency IG Output Frame n Transport Latency Video Cable Video Processing Modulated Light out Projection Lens Frame n Frame n Video Processing Latency Frame n Imaging Latency t0 t1 t2 t3 t4 t5 18
19 Latency Interactions Technology choices Geometry: IG, box or projector Design choices Algorithm System choices Image geometry Smear reduction Frame rate 19
20 Latency Interactions Technology choices Geometry: IG, box or projector Geometry: IG, box or projector Design choices Algorithm System choices Image geometry Smear reduction Interface with calibration system Algorithm Image geometry Pixel shifted vertically up the most (default landscape orientation) drives latency Frame rate Smear reduction and frame rate Can reduce latency 20
21 Latency Measurement System parameters Typical geometry Smear reduction Frame rate Instrument Define Measurement / Technique Last pixel to last light (L->L) First pixel to last light (L->L + transport delay) IG Vertical Sync Data Active Projected Light Projector First-to-First Last-to-Last (recommended) F IV F ID L ID L IV F OIL F OFF L OIL L OFF PIN diode Transport = F( frame rate ) Video Processing = F( geometry ) Imaging = F( frame rate, smear reduction ) 21
22 Uniformity Interactions Technology choices Pixel size Design choices Brightness Contrast System choices Lens type Lens shift 22
23 Uniformity Interactions Technology choices Pixel size Design choices Brightness Contrast System choices Lens type Lens shift Optics complexity Pixel size Diffraction effects Brightness and contrast Increasing uniformity (optically or electronically) reduces brightness and contrast Lens type and shift Shift-capable lenses improve uniformity Uniformity typically y degrades away from zero shift 23
24 Uniformity Measurement System parameters Typically specified at zero offset Instrument Define Measurement / Technique Typically without electronic correction White flat field 9-pt, 13-pt, 17-pt, center-to-corner 24
25 Smear Interactions Technology choices Design choices Algorithm Brightness System choices Frame rate Latency 25
26 Smear Interactions Technology choices Design choices Algorithm Brightness System choices Frame rate Latency More modulators permits shorter display time (to a point) Algorithm Algorithm choices can impact tradeoff between smear reduction and hold time Brightness Higher brightness permits shorter hold time (to a point) 26
27 Smear Interactions Technology choices Frame rate Design choices Algorithm Brightness System choices Frame rate Latency If projector is capable of the increased refresh rate, increasing frame rate reduces smear with less impact on brightness Latency Reducing hold time can reduce latency 27
28 2012 Thank you. Questions?
29 2012 Thank you. Questions?
SIM University Color, Brightness, Contrast, Smear Reduction and Latency. Stuart Nicholson Program Architect, VE.
2012 2012 Color, Brightness, Contrast, Smear Reduction and Latency 2 Stuart Nicholson Program Architect, VE Overview Topics Color Luminance (Brightness) Contrast Smear Latency Objective What is it? How
More informationReikan FoCal Aperture Sharpness Test Report
Focus Calibration and Analysis Software Test run on: 26/01/2016 17:02:00 with FoCal 2.0.6.2416W Report created on: 26/01/2016 17:03:39 with FoCal 2.0.6W Overview Test Information Property Description Data
More informationReikan FoCal Aperture Sharpness Test Report
Focus Calibration and Analysis Software Reikan FoCal Sharpness Test Report Test run on: 26/01/2016 17:14:35 with FoCal 2.0.6.2416W Report created on: 26/01/2016 17:16:16 with FoCal 2.0.6W Overview Test
More informationReikan FoCal Aperture Sharpness Test Report
Focus Calibration and Analysis Software Reikan FoCal Sharpness Test Report Test run on: 10/02/2016 19:57:05 with FoCal 2.0.6.2416W Report created on: 10/02/2016 19:59:09 with FoCal 2.0.6W Overview Test
More informationReikan FoCal Aperture Sharpness Test Report
Focus Calibration and Analysis Software Reikan FoCal Sharpness Test Report Test run on: 27/01/2016 00:35:25 with FoCal 2.0.6.2416W Report created on: 27/01/2016 00:41:43 with FoCal 2.0.6W Overview Test
More informationMEASURING HEAD-UP DISPLAYS FROM 2D TO AR: SYSTEM BENEFITS & DEMONSTRATION Presented By Matt Scholz November 28, 2018
MEASURING HEAD-UP DISPLAYS FROM 2D TO AR: SYSTEM BENEFITS & DEMONSTRATION Presented By Matt Scholz November 28, 2018 Light & Color Automated Visual Inspection Global Support TODAY S AGENDA The State of
More informationReikan FoCal Aperture Sharpness Test Report
Focus Calibration and Analysis Software Test run on: 26/01/2016 17:56:23 with FoCal 2.0.6.2416W Report created on: 26/01/2016 17:59:12 with FoCal 2.0.6W Overview Test Information Property Description Data
More informationImaging Photometer and Colorimeter
W E B R I N G Q U A L I T Y T O L I G H T. /XPL&DP Imaging Photometer and Colorimeter Two models available (photometer and colorimetry camera) 1280 x 1000 pixels resolution Measuring range 0.02 to 200,000
More informationOptical design of a high resolution vision lens
Optical design of a high resolution vision lens Paul Claassen, optical designer, paul.claassen@sioux.eu Marnix Tas, optical specialist, marnix.tas@sioux.eu Prof L.Beckmann, l.beckmann@hccnet.nl Summary:
More informationSome of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design)
Lens design Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design) Focal length (f) Field angle or field size F/number
More informationG-700 multiple Channel 4K Curve Edge Blending Processor
G-700 multiple Channel 4K Curve Edge Blending Processor G-700 is a curved screen edge blending processor with the ability to provide multiple processing modules to control from 1 to 4 projectors based
More informationThe ultimate in 4K laser projection
The ultimate in 4K laser projection Harness the compact power of 4K laser projection Bring visuals to life with Canon s compact 4k laser, LCOS installation projector the innovative XEED 4K600STZ. Countless
More informationWhite Paper Focusing more on the forest, and less on the trees
White Paper Focusing more on the forest, and less on the trees Why total system image quality is more important than any single component of your next document scanner Contents Evaluating total system
More informationAbout 3D perception. Experience & Innovation: Powered by People
About 3D perception 3D perception designs and supplies seamless immersive visual display solutions and technologies for simulation and visualization applications. 3D perception s Northstar ecosystem of
More informationBIG PIXELS VS. SMALL PIXELS THE OPTICAL BOTTLENECK. Gregory Hollows Edmund Optics
BIG PIXELS VS. SMALL PIXELS THE OPTICAL BOTTLENECK Gregory Hollows Edmund Optics 1 IT ALL STARTS WITH THE SENSOR We have to begin with sensor technology to understand the road map Resolution will continue
More informationEdge Blender Controller
Edge Blender Controller Calibration Manual Version 2017 V1 Contents Contents INTRODUCTION 1 FEATURES 1 OS AND HARDWARE 1 INSTALLATION 2 INSTALLATION 2 UNINSTALLATION 4 INTERFACE 6 COMMUNICATION 7 CONFIG
More informationMTF characteristics of a Scophony scene projector. Eric Schildwachter
MTF characteristics of a Scophony scene projector. Eric Schildwachter Martin MarieUa Electronics, Information & Missiles Systems P0 Box 555837, Orlando, Florida 32855-5837 Glenn Boreman University of Central
More informationDLA-RS20 Full HD D-ILA Front Projector
DLA-RS20 Full HD D-ILA Front Projector With the new DLA-RS20, the bigger the screen, the better the picture. Now every seat in your mini theater is the best in the house! The new DLA-RS20 brings THX certified
More informationAbout 3D perception. Experience & Innovation: Powered by People
Simulation About 3D perception 3D perception enables immersive, engaging, and meaningful visual experiences for the professional simulation and visualization marketplaces. Since our beginning in 1997,
More informationFULL RESOLUTION 2K DIGITAL PROJECTION - by EDCF CEO Dave Monk
FULL RESOLUTION 2K DIGITAL PROJECTION - by EDCF CEO Dave Monk 1.0 Introduction This paper is intended to familiarise the reader with the issues associated with the projection of images from D Cinema equipment
More informationOptical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH
Optical basics for machine vision systems Lars Fermum Chief instructor STEMMER IMAGING GmbH www.stemmer-imaging.de AN INTERNATIONAL CONCEPT STEMMER IMAGING customers in UK Germany France Switzerland Sweden
More informationPractical Image and Video Processing Using MATLAB
Practical Image and Video Processing Using MATLAB Chapter 1 Introduction and overview What will we learn? What is image processing? What are the main applications of image processing? What is an image?
More informationHigh Dynamic Range Displays
High Dynamic Range Displays Dave Schnuelle Senior Director, Image Technology Dolby Laboratories The Demise of the CRT What was good: Large viewing angle High contrast Consistent EO transfer function Good
More informationCMOS Star Tracker: Camera Calibration Procedures
CMOS Star Tracker: Camera Calibration Procedures By: Semi Hasaj Undergraduate Research Assistant Program: Space Engineering, Department of Earth & Space Science and Engineering Supervisor: Dr. Regina Lee
More informationSpeckle free laser projection
Speckle free laser projection With Optotune s Laser Speckle Reducer October 2013 Dr. Selina Casutt, Application Engineer Bernstrasse 388 CH-8953 Dietikon Switzerland Phone +41 58 856 3011 www.optotune.com
More informationVariable microinspection system. system125
Variable microinspection system system125 Variable micro-inspection system Characteristics Large fields, high NA The variable microinspection system mag.x system125 stands out from conventional LD inspection
More informationTECHSPEC COMPACT FIXED FOCAL LENGTH LENS
Designed for use in machine vision applications, our TECHSPEC Compact Fixed Focal Length Lenses are ideal for use in factory automation, inspection or qualification. These machine vision lenses have been
More informationAPPLICATIONS FOR TELECENTRIC LIGHTING
APPLICATIONS FOR TELECENTRIC LIGHTING Telecentric lenses used in combination with telecentric lighting provide the most accurate results for measurement of object shapes and geometries. They make attributes
More informationTechnical Note How to Compensate Lateral Chromatic Aberration
Lateral Chromatic Aberration Compensation Function: In JAI color line scan cameras (3CCD/4CCD/3CMOS/4CMOS), sensors and prisms are precisely fabricated. On the other hand, the lens mounts of the cameras
More informationLaser Diode Mounting Kits
Laser Diode Mounting Kits For Ø5.6mm and Ø9mm Laser Diodes Complete Mounting System with Collimating Lens If your work involves laser diodes, you ll appreciate the benefits of Optima s laser diode mounting
More informationImage Capture and Problems
Image Capture and Problems A reasonable capture IVR Vision: Flat Part Recognition Fisher lecture 4 slide 1 Image Capture: Focus problems Focus set to one distance. Nearby distances in focus (depth of focus).
More informationComprehensive Vicarious Calibration and Characterization of a Small Satellite Constellation Using the Specular Array Calibration (SPARC) Method
This document does not contain technology or Technical Data controlled under either the U.S. International Traffic in Arms Regulations or the U.S. Export Administration Regulations. Comprehensive Vicarious
More informationUsing Optics to Optimize Your Machine Vision Application
Expert Guide Using Optics to Optimize Your Machine Vision Application Introduction The lens is responsible for creating sufficient image quality to enable the vision system to extract the desired information
More informationPerformance of Image Intensifiers in Radiographic Systems
DOE/NV/11718--396 LA-UR-00-211 Performance of Image Intensifiers in Radiographic Systems Stuart A. Baker* a, Nicholas S. P. King b, Wilfred Lewis a, Stephen S. Lutz c, Dane V. Morgan a, Tim Schaefer a,
More informationThe Fastest, Easiest, Most Accurate Way To Compare Parts To Their CAD Data
210 Brunswick Pointe-Claire (Quebec) Canada H9R 1A6 Web: www.visionxinc.com Email: info@visionxinc.com tel: (514) 694-9290 fax: (514) 694-9488 VISIONx INC. The Fastest, Easiest, Most Accurate Way To Compare
More informationINFLUENCE OF VARIABLE APERTURE STOP
INFLUENCE OF VARIABLE APERTURE STOP IN TELECENTRIC IMAGING LENSES SILL OPTICS GMBH CO. KG TECHNOLOGY FORUM MACHINE VISION 2015/16 Konrad Hentschel, Dipl-Phys. Andreas Platz, M.Sc. Project Management CONTENT
More informationCopyright 2000 Society of Photo Instrumentation Engineers.
Copyright 2000 Society of Photo Instrumentation Engineers. This paper was published in SPIE Proceedings, Volume 4043 and is made available as an electronic reprint with permission of SPIE. One print or
More informationEC-433 Digital Image Processing
EC-433 Digital Image Processing Lecture 2 Digital Image Fundamentals Dr. Arslan Shaukat 1 Fundamental Steps in DIP Image Acquisition An image is captured by a sensor (such as a monochrome or color TV camera)
More informationNP40/50/60 Installation Guide Ceiling Mounted and Desktop Rev 1.2
Contents Product Description, Lens Specs, Notes and Formulas Pg 1 Diagrams & Distance Charts Pg 2 Cabinet Dimensions Pg 3 Cabinet Dimensions cont. Pg 4 Ceiling Mount Dimensions Pg 5 Input Panel and Control
More informationOptoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790
Calibration Standard for Sighting & Imaging Devices 2223 West San Bernardino Road West Covina, California 91790 Phone: (626) 962-5181 Fax: (626) 962-5188 www.davidsonoptronics.com sales@davidsonoptronics.com
More informationWHITE PAPER. Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception
Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception Abstract
More informationevolume Technical lighting without frills
evolume Technical lighting without frills Technical perfection for streets and roads Evolume combines excellent lighting properties and visual comfort with a modern cost-effective design. Thanks to its
More informationWhite Paper: Convergence & Lateral Chromatic Aberration
DATE 20 April 2018 TO whom it may concern CC FROM Product Management Projection White Paper: Convergence & Lateral Chromatic Aberration The image quality of 3-chip DLP projectors depends on a lot of factors:
More informationCalibration considerations for a reduced-timeline optimized approach for VNIR earthorbiting
Calibration considerations for a reduced-timeline optimized approach for VNIR earthorbiting satellites Zachary Bergen, Joe Tansock Space Dynamics Laboratory 1695 North Research Park Way, North Logan, UT
More informationCompact High Resolution Imaging Spectrometer (CHRIS) siraelectro-optics
Compact High Resolution Imaging Spectrometer (CHRIS) Mike Cutter (Mike_Cutter@siraeo.co.uk) Summary CHRIS Instrument Design Instrument Specification & Performance Operating Modes Calibration Plan Data
More informationUsing the Large Linear Verification Kit
Quick Start Guide Using the Large Linear Verification Kit Purpose This document provides guidance to users of the Large Linear Verification Kit, part number SLN-0000006. The kit consists of a light, bracket,
More informationVELVET The High Contrast Simulation Projector
VELVET The High Contrast Simulation Projector June 1 st, 2016 FMPT Conference Berlin Air Show Sven Ziebart, Axel Krause Content Gamma curve and contrast of a projector 1 Optical properties of 2 Digital
More informationME 6406 MACHINE VISION. Georgia Institute of Technology
ME 6406 MACHINE VISION Georgia Institute of Technology Class Information Instructor Professor Kok-Meng Lee MARC 474 Office hours: Tues/Thurs 1:00-2:00 pm kokmeng.lee@me.gatech.edu (404)-894-7402 Class
More informationECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the
ECEN 4606 Lab 8 Spectroscopy SUMMARY: ROBLEM 1: Pedrotti 3 12-10. In this lab, you will design, build and test an optical spectrum analyzer and use it for both absorption and emission spectroscopy. The
More informationColor Digital Imaging: Cameras, Scanners and Monitors
Color Digital Imaging: Cameras, Scanners and Monitors H. J. Trussell Dept. of Electrical and Computer Engineering North Carolina State University Raleigh, NC 27695-79 hjt@ncsu.edu Color Imaging Devices
More informationDCP D Cinema Projectors. Lens configurations
DCP D Cinema Projectors Lens configurations 1 DCP Projected Image Native Resolution Of The DCP Projector: Native resolution of the DLP chip: 2048 x 1080 pixel (square pixel) aspect ratio of 1,9 : 1 With
More informationDECODING SCANNING TECHNOLOGIES
DECODING SCANNING TECHNOLOGIES Scanning technologies have improved and matured considerably over the last 10-15 years. What initially started as large format scanning for the CAD market segment in the
More informationImaging across the world. Hiroshi Matsumoto, Munehiro Ogasawara and Kiyoshi Hattori April 18 th, 2013
Imaging across the world PMJ 213 Panel Discussion Challenges for future EB mask writers Hiroshi Matsumoto, Munehiro Ogasawara and Kiyoshi Hattori April 18 th, 213 vs. pixelated gray beam Two shaping apertures
More informationREPLICATING HUMAN VISION FOR ACCURATE TESTING OF AR/VR DISPLAYS Presented By Eric Eisenberg February 22, 2018
REPLICATING HUMAN VISION FOR ACCURATE TESTING OF AR/VR DISPLAYS Presented By Eric Eisenberg February 22, 2018 Light & Color Automated Visual Inspection Global Support TODAY S AGENDA Challenges in Near-Eye
More informationMeasurement of Visual Resolution of Display Screens
Measurement of Visual Resolution of Display Screens Michael E. Becker Display-Messtechnik&Systeme D-72108 Rottenburg am Neckar - Germany Abstract This paper explains and illustrates the meaning of luminance
More information(12) Patent Application Publication (10) Pub. No.: US 2003/ A1. Penn et al. (43) Pub. Date: Aug. 7, 2003
US 2003O147052A1 (19) United States (12) Patent Application Publication (10) Pub. No.: US 2003/0147052 A1 Penn et al. (43) Pub. Date: (54) HIGH CONTRAST PROJECTION Related U.S. Application Data (60) Provisional
More informationWHITE PAPER. Guide to CCD-Based Imaging Colorimeters
Guide to CCD-Based Imaging Colorimeters How to choose the best imaging colorimeter CCD-based instruments offer many advantages for measuring light and color. When configured effectively, CCD imaging systems
More informationHow interference filters can outperform colored glass filters in automated vision applications
How interference filters can outperform colored glass filters in automated vision applications High Performance Machine Vision Filters from Chroma It s all about the contrast Vision applications rely on
More informationReflection! Reflection and Virtual Image!
1/30/14 Reflection - wave hits non-absorptive surface surface of a smooth water pool - incident vs. reflected wave law of reflection - concept for all electromagnetic waves - wave theory: reflected back
More informationDensity vs. Contrast
Density vs. Contrast In your negatives, density is controlled by the number of exposed crystals in your film which have been converted to hardened silver during processing. A dense negative (over exposed)
More informationAn Indian Journal FULL PAPER. Trade Science Inc. Parameters design of optical system in transmitive star simulator ABSTRACT KEYWORDS
[Type text] [Type text] [Type text] ISSN : 0974-7435 Volume 10 Issue 23 BioTechnology 2014 An Indian Journal FULL PAPER BTAIJ, 10(23), 2014 [14257-14264] Parameters design of optical system in transmitive
More informationHeads Up and Near Eye Display!
Heads Up and Near Eye Display! What is a virtual image? At its most basic, a virtual image is an image that is projected into space. Typical devices that produce virtual images include corrective eye ware,
More informationIt should also be noted that with modern cameras users can choose for either
White paper about color correction More drama Many application fields like digital printing industry or the human medicine require a natural display of colors. To illustrate the importance of color fidelity,
More informationinphoto ID Canon and Olympus camera control software Automatic ID photography User Guide
inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide 2006 Akond company 197342, Russia, St.-Petersburg, Serdobolskaya, 65a Phone/fax: +7(812)600-6918 Cell: +7(921)757-8319
More informationT I P S F O R I M P R O V I N G I M A G E Q U A L I T Y O N O Z O F O O T A G E
T I P S F O R I M P R O V I N G I M A G E Q U A L I T Y O N O Z O F O O T A G E Updated 20 th Jan. 2017 References Creator V1.4.0 2 Overview This document will concentrate on OZO Creator s Image Parameter
More informationThis technical brief provides detailed information on the image quality, performance, and versatility of Epson projectors.
This technical brief provides detailed information on the image quality, performance, and versatility of Epson projectors. Superior Brightness All Epson multimedia projectors include Epson s integrated
More informationCRISATEL High Resolution Multispectral System
CRISATEL High Resolution Multispectral System Pascal Cotte and Marcel Dupouy Lumiere Technology, Paris, France We have designed and built a high resolution multispectral image acquisition system for digitizing
More informationBias errors in PIV: the pixel locking effect revisited.
Bias errors in PIV: the pixel locking effect revisited. E.F.J. Overmars 1, N.G.W. Warncke, C. Poelma and J. Westerweel 1: Laboratory for Aero & Hydrodynamics, University of Technology, Delft, The Netherlands,
More informationPixel CCD RASNIK. Kevan S Hashemi and James R Bensinger Brandeis University May 1997
ATLAS Internal Note MUON-No-180 Pixel CCD RASNIK Kevan S Hashemi and James R Bensinger Brandeis University May 1997 Introduction This note compares the performance of the established Video CCD version
More informationCamera Requirements For Precision Agriculture
Camera Requirements For Precision Agriculture Radiometric analysis such as NDVI requires careful acquisition and handling of the imagery to provide reliable values. In this guide, we explain how Pix4Dmapper
More informationINTERFEROMETER VI-direct
Universal Interferometers for Quality Control Ideal for Production and Quality Control INTERFEROMETER VI-direct Typical Applications Interferometers are an indispensable measurement tool for optical production
More informationREAL-TIME X-RAY IMAGE PROCESSING; TECHNIQUES FOR SENSITIVITY
REAL-TIME X-RAY IMAGE PROCESSING; TECHNIQUES FOR SENSITIVITY IMPROVEMENT USING LOW-COST EQUIPMENT R.M. Wallingford and J.N. Gray Center for Aviation Systems Reliability Iowa State University Ames,IA 50011
More informationLENSES. INEL 6088 Computer Vision
LENSES INEL 6088 Computer Vision Digital camera A digital camera replaces film with a sensor array Each cell in the array is a Charge Coupled Device light-sensitive diode that converts photons to electrons
More informationOptical Performance of the Grating Light Valve Technology
Optical Performance of the Grating Light Valve Technology David T Amm and Robert W Corrigan* Silicon Light Machines, Sunnyvale CA 94089 ABSTRACT The objective of this paper is to detail the Grating Light
More informationMML-High Resolution 5M Series
Fixed Magnification Series -High Resolution 5M Series High-resolution models that possess the best contrast and NA of all Series. Image acquisition with even higher image quality is realized by combining
More informationOptimizing throughput with Machine Vision Lighting. Whitepaper
Optimizing throughput with Machine Vision Lighting Whitepaper Optimizing throughput with Machine Vision Lighting Within machine vision systems, inappropriate or poor quality lighting can often result in
More informationpco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range
edge 4.2 LT scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.8 electrons USB 3.0 small form factor high dynamic range up to 37 500:1 high speed 40 fps high quantum efficiency up to
More informationImproved sensitivity high-definition interline CCD using the KODAK TRUESENSE Color Filter Pattern
Improved sensitivity high-definition interline CCD using the KODAK TRUESENSE Color Filter Pattern James DiBella*, Marco Andreghetti, Amy Enge, William Chen, Timothy Stanka, Robert Kaser (Eastman Kodak
More informationFINELITE 10 Year LED Warranty
10 Industry Best Year LED Warranty Top Glow Diffuser (Standard) Date Project Type Comments Bottom Glow Diffuser (Shown) DESCRIPTION High Performance 2" aperture Indirect/Direct (HP-2 ID) is a patented,
More informationOptics: An Introduction
It is easy to overlook the contribution that optics make to a system; beyond basic lens parameters such as focal distance, the details can seem confusing. This Tech Tip presents a basic guide to optics
More informationDesign Description Document
UNIVERSITY OF ROCHESTER Design Description Document Flat Output Backlit Strobe Dare Bodington, Changchen Chen, Nick Cirucci Customer: Engineers: Advisor committee: Sydor Instruments Dare Bodington, Changchen
More informationAstrophotography. An intro to night sky photography
Astrophotography An intro to night sky photography Agenda Hardware Some myths exposed Image Acquisition Calibration Hardware Cameras, Lenses and Mounts Cameras for Astro-imaging Point and Shoot Limited
More informationDLP Projector LX-MU700
DLP Projector LX-MU700 1. Main Features 1-1. Dual-Lamp Installation Model with High Brightness of 7500 lm The brightness of 7500 lm is attained by the dual lamps installed, and the projector is especially
More informationGetting your Monitor and Prints to display correct Colour*
Getting your Monitor and Prints to display correct Colour* Graeme James 4 April 2011 *Otherwise known as Colour Management Most artists react very warmly to the word colour, and a bit more coolly to the
More informationParameters of Image Quality
Parameters of Image Quality Image Quality parameter Resolution Geometry and Distortion Channel registration Noise Linearity Dynamic range Color accuracy Homogeneity (Illumination) Resolution Usually Stated
More informationVery short introduction to light microscopy and digital imaging
Very short introduction to light microscopy and digital imaging Hernan G. Garcia August 1, 2005 1 Light Microscopy Basics In this section we will briefly describe the basic principles of operation and
More informationGPI INSTRUMENT PAGES
GPI INSTRUMENT PAGES This document presents a snapshot of the GPI Instrument web pages as of the date of the call for letters of intent. Please consult the GPI web pages themselves for up to the minute
More informationNovaCLB-Cabinet Quick Start User Manual
NovaCLB-Cabinet Quick Start User Manual 2017-08-10 V4.0.0 Step 1 Preparations before calibration 1.1 Arrange the darkroom The following requirements and suggestions are proposed for the arrangement of
More informationChapter 5 Nadir looking UV measurement.
Chapter 5 Nadir looking UV measurement. Part-II: UV polychromator instrumentation and measurements -A high SNR and robust polychromator using a 1D array detector- UV spectrometers onboard satellites have
More informationVortex Shedding Past a Triangular Prism
Vortex Shedding Past a Triangular Prism Eli Luke Flow Visualization Prof. Jean Hertzberg & Prof. Alex Sweetman Project #4 (Team Beta) Due 11/8/07 /07 Purpose: This is the fourth project of the semester,
More informationCamera Calibration Certificate No: DMC III 27542
Calibration DMC III Camera Calibration Certificate No: DMC III 27542 For Peregrine Aerial Surveys, Inc. #201 1255 Townline Road Abbotsford, B.C. V2T 6E1 Canada Calib_DMCIII_27542.docx Document Version
More informationLaser Scanning 3D Display with Dynamic Exit Pupil
Koç University Laser Scanning 3D Display with Dynamic Exit Pupil Kishore V. C., Erdem Erden and Hakan Urey Dept. of Electrical Engineering, Koç University, Istanbul, Turkey Hadi Baghsiahi, Eero Willman,
More informationEpson EB-G7000 Series THE POWER TO ENGAGE
2 Epson EB-G7000 Series THE POWER TO ENGAGE INSTALLATION PROJECTORS FOR PROFESSIONAL PRESENTING Transform large venue presenting with our most powerful, versatile and highly reliable installation range.
More informationBe aware that there is no universal notation for the various quantities.
Fourier Optics v2.4 Ray tracing is limited in its ability to describe optics because it ignores the wave properties of light. Diffraction is needed to explain image spatial resolution and contrast and
More informationEUV Plasma Source with IR Power Recycling
1 EUV Plasma Source with IR Power Recycling Kenneth C. Johnson kjinnovation@earthlink.net 1/6/2016 (first revision) Abstract Laser power requirements for an EUV laser-produced plasma source can be reduced
More information2 How to operate the microscope/obtain an image
Morgagni Operating Instructions 50079 010912 2-1 2 ow to operate the microscope/obtain an image 2.1 Starting the microscope 2.1.1 Starting the microscope with several manually-operated steps 1. Turn on
More informationM271X/M311X Installation Guide Ceiling Mounted and Desktop Rev 1.0
Contents Product Description, Lens Specs, Notes and Formulas Pg 1 Diagrams & Distance Charts Pg 2 Cabinet Dimensions Pg 3-4 Ceiling Mount Dimensions Pg 5 Input Panel and Control Codes Pg 6 Product Description
More informationCamera Requirements For Precision Agriculture
Camera Requirements For Precision Agriculture Radiometric analysis such as NDVI requires careful acquisition and handling of the imagery to provide reliable values. In this guide, we explain how Pix4Dmapper
More informationThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer
ThermaViz The Innovative Two-Wavelength Imaging Pyrometer Operating Manual The integration of advanced optical diagnostics and intelligent materials processing for temperature measurement and process control.
More informationCriteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design
Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design Computer Aided Design Several CAD tools use Ray Tracing (see
More information