Xenon-Zirconia 3.3/92

Size: px
Start display at page:

Download "Xenon-Zirconia 3.3/92"

Transcription

1 This lens with.2x magnification is optimized for the use with 12k (62.5 mm) line scan sensors with 5 µm pixel, but can also be used with 16k (82 mm) lines. It is broadband coated and can be used in the spectral range of 4-1 nm. The V-Mount makes it easy to install and rotate into the desired azimuth position for a wide range of line scan applications. Performance is practically diffraction limited over the whole field. At F/#5.6 the lens is free of artificial vignetting. The Xenon-Zirconia lens is designed in a manner that even with fastest F-number, the full resolution, albeit with diminished contrast, is attained, needed for web and FPD inspection. The Xenon-Zirconia lens series also contains lenses with magnification of.33x,.5x,.7x, 1.x, 2.x and 2.x with beam splitter. Xenon-Zirconia 3.3/92 Key features For 12k line scan sensors with 5 μm pixel sizes Vibration-insensitive for stable optical performance Best azimuth marking 4 nm to 1 nm broadband AR coating Lockable distance and aperture settings V-Mount connection Applications Web and surface inspections Quality control FPD inspection PCB inspection OLED inspection Line scan applications Name Xenon-Zirconia 3.3/92 Name Xenon-Zirconia 3.3/92 Type -11 Focal Length [mm] 92 Magnification -.2 Image circle [mm] 62 Resolution [µm] 3.5 F/# range NA.15 Weight [g] 25 Storage temperature [ C] f eff [mm] S F [mm] S F [mm] HH [mm] β P 1.79 Interface V48-Mount S EP [mm] Working distance [mm] 511 AoV [ ] 38 S AP [mm] Σd [mm] Focus control manual ID Transmission [nm] 4-1 Filter thread [mm] M46 x.75 Dimensions L x D [mm] 63. x 55. Jos. Schneider Optische Werke GmbH Version 1. 1/218 Jos. Schneider Optische Werke GmbH is certified ISO 91. We accept no responsibility for any errors and reserve the right of modification without further notice. 1 / 5

2 Distortion vs. Image Height Distortion / % Distortion vs. Field Hei ' = -.16 ' = -.2 ' = -.24 Transmittance vs. Wavelength Transmittance / % Wavelength / nm Relative Illumination vs. Image Height Rel. Illumination vs. Field Position 1 Rel. Illumination / % F# = 3.3, ' = -.16 F# = 4., ' = -.16 F# = 5.6, ' = -.16 F# = 3.3, ' = -.2 F# = 4., ' = -.2 F# = 5.6, ' = -.2 F# = 3.3, ' = -.24 F# = 4., ' = -.24 F# = 5.6, ' = -.24 Jos. Schneider Optische Werke GmbH Version 1. 1/218 Jos. Schneider Optische Werke GmbH is certified ISO 91. We accept no responsibility for any errors and reserve the right of modification without further notice. 2 / 5

3 Spectrum Name VIS Wavelenghts [nm] Weights F# = 3.3, ' = -.16, OO' = 757 F# = 4., ' = -.16, OO' = 756 F# = 5.6, ' = -.16, OO' = F# = 3.3, ' = -.2, OO' = 645 F# = 4., ' = -.2, OO' = 645 F# = 5.6, ' = -.2, OO' = F# = 3.3, ' = -.24, OO' = 572 F# = 4., ' = -.24, OO' = 572 F# = 5.6, ' = -.24, OO' = lp/mm, tangential 18. lp/mm, radial 36. lp/mm, tangential 36. lp/mm, radial 72. lp/mm, tangential 72. lp/mm, radial Jos. Schneider Optische Werke GmbH Version 1. 1/218 Jos. Schneider Optische Werke GmbH is certified ISO 91. We accept no responsibility for any errors and reserve the right of modification without further notice. 3 / 5

4 Accessories Mount Length ID Ext. Tube V48 1 mm V48 25 mm V48 5 mm M72 x.75 5 mm M72 x.75 1 mm M72 x mm 2646 M72 x.75 5 mm M72 x.75 1 mm M9 x 1 1 mm M9 x 1 25 mm M9 x 1 5 mm M9 x 1 1 mm M95 x 1 1 mm M95 x 1 25 mm M95 x 1 5 mm M95 x 1 1 mm Adapter V 48 / C-Mount 8.5 mm V48 / V7 with focusing 1 mm V7 / M72 x M72 x.75 / M95 x 1 4 mm M72 x.75 / M9 x M95 x 1 / M9 x V 48 / M 42 x mm V 48 / M 42 x mm V 48 / M 58 x.75 1 mm Jos. Schneider Optische Werke GmbH Version 1. 1/218 Jos. Schneider Optische Werke GmbH is certified ISO 91. We accept no responsibility for any errors and reserve the right of modification without further notice. 4 / 5

5 Get more information Contact our local offices Headquarter Germany Jos. Schneider Optische Werke GmbH Ringstraße Bad Kreuznach S cs@schneiderkreuznach.com Offices Worldwide China S shawn.liu@schneider-asiapacific.com North America S (East Coast) S (West Coast) info@schneideroptics.com Singapore S thongv@schneiderkreuznach.com Jos. Schneider Optische Werke GmbH Version 1. 1/218 Jos. Schneider Optische Werke GmbH is certified ISO 91. We accept no responsibility for any errors and reserve the right of modification without further notice. 5 / 5

Xenon-Diamond 2.9/106 With beam splitter

Xenon-Diamond 2.9/106 With beam splitter Xenon-Diamond 2.9/16 This high resolution 2.6x line scan lens with beam splitter is optimized for the use with 12k (62.5 mm) line scan sensors with 5 µm pixel, but can also be used with 16k / 5 µm (82

More information

Macro Varon 4.5/85. Key features. Applications. Web and surface inspections

Macro Varon 4.5/85. Key features. Applications. Web and surface inspections The Macro Varon lens has been designed for high resolution 12k line scan cameras with 3.5 µm pixel pitch. They are optimized for an optical magnification range of.5x to 2.x. CAS-lens technology produces

More information

TECHSPEC COMPACT FIXED FOCAL LENGTH LENS

TECHSPEC COMPACT FIXED FOCAL LENGTH LENS Designed for use in machine vision applications, our TECHSPEC Compact Fixed Focal Length Lenses are ideal for use in factory automation, inspection or qualification. These machine vision lenses have been

More information

The Importance of Wavelengths on Optical Designs

The Importance of Wavelengths on Optical Designs 1 The Importance of Wavelengths on Optical Designs Bad Kreuznach, Oct. 2017 2 Introduction A lens typically needs to be corrected for many different parameters as e.g. distortion, astigmatism, spherical

More information

Variable microinspection system. system125

Variable microinspection system. system125 Variable microinspection system system125 Variable micro-inspection system Characteristics Large fields, high NA The variable microinspection system mag.x system125 stands out from conventional LD inspection

More information

Basler Accessories. Technical Specification BASLER LENS C M. Order Number

Basler Accessories. Technical Specification BASLER LENS C M. Order Number Basler Accessories Technical Specification BASLER LENS C23-526-2M Order Number 22183 Document Number: DG1916 Version: 1 Language: (English) Release Date: 17 January 218 Contacting Basler Support Worldwide

More information

Basler Accessories. Technical Specification BASLER LENS C M. Order Number

Basler Accessories. Technical Specification BASLER LENS C M. Order Number Basler Accessories Technical Specification BASLER LENS C23-1616-2M Order Number 2200000180 Document Number: DG001913 Version: 01 Language: 000 (English) Release Date: 17 January 2018 Contacting Basler

More information

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH Optical basics for machine vision systems Lars Fermum Chief instructor STEMMER IMAGING GmbH www.stemmer-imaging.de AN INTERNATIONAL CONCEPT STEMMER IMAGING customers in UK Germany France Switzerland Sweden

More information

For high resolution, large-sized line sensor cameras. Recommendable line sensor cameras - 5.2μm x 12K / 7μm x 8K

For high resolution, large-sized line sensor cameras. Recommendable line sensor cameras - 5.2μm x 12K / 7μm x 8K Nikon Rayfact Series Features For high resolution, large-sized line sensor cameras. Recommendable line sensor cameras - 5.2μm x 12K / 7μm x 8K Guarantee high resolution and uniformity from the center to

More information

Nikon Rayfact VF. Features. Applications. ver2.2

Nikon Rayfact VF. Features. Applications. ver2.2 Nikon Rayfact VF Features Variable magnification range : 0.5x - 3.0x Image size φ 64mm to meet large-sized high resolution line censor cameras. Suitable for line censor cameras of 7μm x 8K / 5μm x 12K.

More information

Optical and mechanical parameters. 100 mm N. of elements 20.5 mm Dimensions 11.7 degrees Weight F/N = 4 (fixed) N.A.

Optical and mechanical parameters. 100 mm N. of elements 20.5 mm Dimensions 11.7 degrees Weight F/N = 4 (fixed) N.A. OB SWIR 100 LENS OB-SWIR100/4 P/N C0416 General Description This family of high resolution SWIR lenses image from 0.9 2.3 µmm making them especially well-suited for PCB inspection, special laser applications,

More information

INFLUENCE OF VARIABLE APERTURE STOP

INFLUENCE OF VARIABLE APERTURE STOP INFLUENCE OF VARIABLE APERTURE STOP IN TELECENTRIC IMAGING LENSES SILL OPTICS GMBH CO. KG TECHNOLOGY FORUM MACHINE VISION 2015/16 Konrad Hentschel, Dipl-Phys. Andreas Platz, M.Sc. Project Management CONTENT

More information

Telecentric lenses.

Telecentric lenses. Telecentric lenses 2014 Bi-Telecentric lenses Titolo Index Descrizione Telecentric lenses Opto Engineering Telecentric lenses represent our core business: these products benefit from a decade-long effort

More information

Speed and Image Brightness uniformity of telecentric lenses

Speed and Image Brightness uniformity of telecentric lenses Specialist Article Published by: elektronikpraxis.de Issue: 11 / 2013 Speed and Image Brightness uniformity of telecentric lenses Author: Dr.-Ing. Claudia Brückner, Optics Developer, Vision & Control GmbH

More information

LENS OB-SWIR500/7 P/N C0615

LENS OB-SWIR500/7 P/N C0615 LENS OB-SWIR500/7 P/N C0615 General Description This family of high resolution SWIR lenses image from 0.9 2.3 m making them especially well-suited for PCB inspection, special laser applications, surveillance

More information

Using Optics to Optimize Your Machine Vision Application

Using Optics to Optimize Your Machine Vision Application Expert Guide Using Optics to Optimize Your Machine Vision Application Introduction The lens is responsible for creating sufficient image quality to enable the vision system to extract the desired information

More information

LENS ZOOM-SWIR 7x P/N C0628

LENS ZOOM-SWIR 7x P/N C0628 ZOOM SWIR 7x LENS ZOOM-SWIR 7x P/N C0628 General Description This family of high resolution SWIR lenses image from 0.9 2.3 m making them especially well-suited for PCB inspection, special laser applications,

More information

OptiSpheric IOL. Integrated Optical Testing of Intraocular Lenses

OptiSpheric IOL. Integrated Optical Testing of Intraocular Lenses OptiSpheric IOL Integrated Optical Testing of Intraocular Lenses OPTICAL TEST STATION OptiSpheric IOL ISO 11979 Intraocular Lens Testing OptiSpheric IOL PRO with in air tray on optional instrument table

More information

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G APPLICATION NOTE M01 attocfm I for Surface Quality Inspection Confocal microscopes work by scanning a tiny light spot on a sample and by measuring the scattered light in the illuminated volume. First,

More information

CALIBRATION REPORT SUMMARY

CALIBRATION REPORT SUMMARY CALIBRATION REPORT SUMMARY Material Description Assembly 2PADI080 1027 0997 A / 09A Camera Module 1 CCD KODAK KAF 39Mp Full Frame Color Image Sensor SN CQ011027 Lens Schneider Apo Digitar 4.0/80 N SN 15006871

More information

LEICA VARIO-ELMARIT-R mm f/2,8-4,5 ASPH. 1

LEICA VARIO-ELMARIT-R mm f/2,8-4,5 ASPH. 1 LEICA VARIO-ELMARIT-R -9 mm f/,-4, ASPH. The LEICA VARIO-ELMARIT-R -9mm f/.-4. ASPH. is a truly universal lens, which covers a broad range of focal lengths but still proves very fast. It is a lens which,

More information

7x P/N C1601. General Description

7x P/N C1601. General Description METRICZOOM SWIR 7x METRIC ZOOM-SWIR ZOOM 7x P/N C1601 C General Description This family of high resolution METRIC ZOOM SWIR lenses image from 0.9 to 2.3 µm making them especially well-suited well for surveillance,

More information

Calibration Report. Short Version. Vexcel Imaging GmbH, A-8010 Graz, Austria

Calibration Report. Short Version. Vexcel Imaging GmbH, A-8010 Graz, Austria Calibration Report Short Version Camera: Manufacturer: UltraCam D, S/N UCD-SU-2-0039 Vexcel Imaging GmbH, A-8010 Graz, Austria Date of Calibration: Mar-14-2011 Date of Report: Mar-17-2011 Camera Revision:

More information

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

IMAGE SENSOR SOLUTIONS. KAC-96-1/5 Lens Kit. KODAK KAC-96-1/5 Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2 KODAK for use with the KODAK CMOS Image Sensors November 2004 Revision 2 1.1 Introduction Choosing the right lens is a critical aspect of designing an imaging system. Typically the trade off between image

More information

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera Figure 1. The Zeta-20 uses the Grasshopper3 and produces true color 3D optical images with multi mode optics technology 3D optical profiling

More information

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember Günter Toesko - Laserseminar BLZ im Dezember 2009 1 Aberrations An optical aberration is a distortion in the image formed by an optical system compared to the original. It can arise for a number of reasons

More information

Where Image Quality Begins

Where Image Quality Begins Where Image Quality Begins Filters are a Necessity Not an Accessory Inexpensive Insurance Policy for the System The most cost effective way to improve repeatability and stability in any machine vision

More information

LEICA Summarit-S 70 mm ASPH. f/2.5 / CS

LEICA Summarit-S 70 mm ASPH. f/2.5 / CS Technical Data. Illustration 1:2 Technical Data Order no. 1155 (CS: 1151) Image angle (diagonal, horizontal, vertical) approx. 42 / 35 / 24, corresponds to approx. 56 focal length in 35 format Optical

More information

Optical design of a high resolution vision lens

Optical design of a high resolution vision lens Optical design of a high resolution vision lens Paul Claassen, optical designer, paul.claassen@sioux.eu Marnix Tas, optical specialist, marnix.tas@sioux.eu Prof L.Beckmann, l.beckmann@hccnet.nl Summary:

More information

Calibration Report. Short version. UltraCam Xp, S/N UC-SXp Vexcel Imaging GmbH, A-8010 Graz, Austria

Calibration Report. Short version. UltraCam Xp, S/N UC-SXp Vexcel Imaging GmbH, A-8010 Graz, Austria Calibration Report Short version Camera: Manufacturer: UltraCam Xp, S/N UC-SXp-1-61212452 Vexcel Imaging GmbH, A-8010 Graz, Austria Date of Calibration: Mar-05-2009 Date of Report: Mar-13-2009 Camera Revision:

More information

Calibration Report. Short version. UltraCam X, S/N UCX-SX Microsoft Photogrammetry, A-8010 Graz, Austria. ( 1 of 13 )

Calibration Report. Short version. UltraCam X, S/N UCX-SX Microsoft Photogrammetry, A-8010 Graz, Austria. ( 1 of 13 ) Calibration Report Short version Camera: Manufacturer: UltraCam X, S/N UCX-SX-1-30518177 Microsoft Photogrammetry, A-8010 Graz, Austria Date of Calibration: May-24-2007 Date of Report: Jun-21-2007 Camera

More information

Calibration Report. Vexcel Imaging GmbH, A-8010 Graz, Austria

Calibration Report. Vexcel Imaging GmbH, A-8010 Graz, Austria Calibration Report Camera: Manufacturer: UltraCam D, S/N UCD-SU-1-0031 Vexcel Imaging GmbH, A-8010 Graz, Austria Date of Calibration: Apr-10-2009 Date of Report: Feb-15-2010 Camera Revision: 4.0 Revision

More information

Coherent Laser Measurement and Control Beam Diagnostics

Coherent Laser Measurement and Control Beam Diagnostics Coherent Laser Measurement and Control M 2 Propagation Analyzer Measurement and display of CW laser divergence, M 2 (or k) and astigmatism sizes 0.2 mm to 25 mm Wavelengths from 220 nm to 15 µm Determination

More information

Optical design of camera optics for mobile phones

Optical design of camera optics for mobile phones Adv. Opt. echn., Vol. 1 (2012), pp. 51 58 Copyright 2012 HOSS Media and De Gruyter. DOI 10.1515/aot-2012-0002 esearch Article Optical design of camera optics for mobile phones homas Steinich and Vladan

More information

Nikon Rayfact Series. Features. Applications. ver2.2

Nikon Rayfact Series. Features. Applications. ver2.2 Nikon Rayfact Series Features Rayfact 2x and 1x : successor models to Printing Nikkor Lenses. No lens aberration (0.0%) at the standard magnification ratio. Guarantee high resolution and uniformity from

More information

Imaging Optics Fundamentals

Imaging Optics Fundamentals Imaging Optics Fundamentals Gregory Hollows Director, Machine Vision Solutions Edmund Optics Why Are We Here? Topics for Discussion Fundamental Parameters of your system Field of View Working Distance

More information

Datasheet. ELIIXA+ 16k/8k CP Cmos Multi-Line Color Camera. Features. Description. Application. Contact us online at: e2v.

Datasheet. ELIIXA+ 16k/8k CP Cmos Multi-Line Color Camera. Features. Description. Application. Contact us online at: e2v. Datasheet ELIIXA+ 16k/8k CP Cmos Multi-Line Color Camera Features Cmos Colour Sensor : - 16384 RGB Pixels, 5 x 5µm (Full Definition) - 8192 RGB Pixels 10x10µm (True Colour) Interface : CoaXPress (4x 6Gb/sLinks)

More information

Spatial-Phase-Shift Imaging Interferometry Using Spectrally Modulated White Light Source

Spatial-Phase-Shift Imaging Interferometry Using Spectrally Modulated White Light Source Spatial-Phase-Shift Imaging Interferometry Using Spectrally Modulated White Light Source Shlomi Epshtein, 1 Alon Harris, 2 Igor Yaacobovitz, 1 Garrett Locketz, 3 Yitzhak Yitzhaky, 4 Yoel Arieli, 5* 1AdOM

More information

CORPORATE PRESENTATION

CORPORATE PRESENTATION CORPORATE PRESENTATION WHO WE ARE Edmund Optics is a global OPTICS and IMAGING company that manufactures and supplies the worldwide technical community with precision optical components and subassemblies.

More information

Telecentric Imaging Object space telecentricity stop source: edmund optics The 5 classical Seidel Aberrations First order aberrations Spherical Aberration (~r 4 ) Origin: different focal lengths for different

More information

Filter & Spectrometer Electron Optics

Filter & Spectrometer Electron Optics Filter & Spectrometer Electron Optics Parameters Affecting Practical Performance Daniel Moonen & Harold A. Brink Did Something Go Wrong? 30 20 10 0 500 600 700 800 900 1000 1100 ev 1 Content The Prism

More information

Advanced Optics for Vision. Stuart W. Singer Sr. Vice President & CTO Schneider Optics, Inc.

Advanced Optics for Vision. Stuart W. Singer Sr. Vice President & CTO Schneider Optics, Inc. Advanced Optics for Vision Stuart W. Singer Sr. Vice President & CTO Schneider Optics, Inc. Table of Contents Modulation Transfer Function (MTF) What does it mean Aberration effects f/number effects Manufacturing

More information

Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design)

Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design) Lens design Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design) Focal length (f) Field angle or field size F/number

More information

MML-High Resolution 5M Series

MML-High Resolution 5M Series Fixed Magnification Series -High Resolution 5M Series High-resolution models that possess the best contrast and NA of all Series. Image acquisition with even higher image quality is realized by combining

More information

Math, Magic & MTF: A Cheat Sheet For The Vision System Community. By Stuart W. Singer, senior VP & CTO, and Jim Sullivan, director, Industrial Optics

Math, Magic & MTF: A Cheat Sheet For The Vision System Community. By Stuart W. Singer, senior VP & CTO, and Jim Sullivan, director, Industrial Optics Math, Magic & MTF: A Cheat Sheet For The Vision System Community By Stuart W. Singer, senior VP & CTO, and Jim Sullivan, director, Industrial Optics The best indicator of lens performance what every buyer

More information

Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA

Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA Array LaserLink Pattern Scanning Laser Technology Pattern Scanning Laser can reduce photocoagulation treatment time by as much as 60% Pattern

More information

Press Release. New packaging design for B+W filters. BAD KREUZNACH, 20 September Stylish appearance and clear orientation for the customer

Press Release. New packaging design for B+W filters. BAD KREUZNACH, 20 September Stylish appearance and clear orientation for the customer Press Release BAD KREUZNACH, 20 September 2018 New packaging design for B+W filters Stylish appearance and clear orientation for the customer Informative and high-quality at the same time: Both retailers

More information

Optical Requirements

Optical Requirements Optical Requirements Transmission vs. Film Thickness A pellicle needs a good light transmission and long term transmission stability. Transmission depends on the film thickness, film material and any anti-reflective

More information

SpectroMaster. High Precision Automatic Spectrometer-Goniometer

SpectroMaster. High Precision Automatic Spectrometer-Goniometer SpectroMaster High Precision Automatic Spectrometer-Goniometer CONTENTS Overview 3 Measurement Principle 3 Error Analysis and System Requirements 4 Goniometer Error...4 Ambient Conditions...6 Sample Quality...6

More information

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design Computer Aided Design Several CAD tools use Ray Tracing (see

More information

Calibration Report. UltraCam Eagle, S/N UC-Eagle f80. Vexcel Imaging GmbH, A-8010 Graz, Austria

Calibration Report. UltraCam Eagle, S/N UC-Eagle f80. Vexcel Imaging GmbH, A-8010 Graz, Austria Calibration Report Camera: Manufacturer: UltraCam Eagle, S/N UC-Eagle-1-60411397-f80 Vexcel Imaging GmbH, A-8010 Graz, Austria Date of Calibration: Jul-23-2013 Date of Report: Aug-06-2013 Camera Revision:

More information

BIG PIXELS VS. SMALL PIXELS THE OPTICAL BOTTLENECK. Gregory Hollows Edmund Optics

BIG PIXELS VS. SMALL PIXELS THE OPTICAL BOTTLENECK. Gregory Hollows Edmund Optics BIG PIXELS VS. SMALL PIXELS THE OPTICAL BOTTLENECK Gregory Hollows Edmund Optics 1 IT ALL STARTS WITH THE SENSOR We have to begin with sensor technology to understand the road map Resolution will continue

More information

Transmission Electron Microscopy 9. The Instrument. Outline

Transmission Electron Microscopy 9. The Instrument. Outline Transmission Electron Microscopy 9. The Instrument EMA 6518 Spring 2009 02/25/09 Outline The Illumination System The Objective Lens and Stage Forming Diffraction Patterns and Images Alignment and Stigmation

More information

mm F2.6 6MP IR-Corrected. Sensor size

mm F2.6 6MP IR-Corrected. Sensor size 1 1 inch and 1/1.2 inch image size spec. Sensor size 1-inch 1/1.2-inch 2/3-inch Image circle OK OK OK OK 1/1.8-inch OK 1/2-inch OK 1/2.5-inch 1 1-inch CMV4000 PYTHON5000 KAI-02150 KAI-2020 KAI-2093 KAI-4050

More information

Performance data of a new 248 nm CD metrology tool proved on COG reticles and PSM s

Performance data of a new 248 nm CD metrology tool proved on COG reticles and PSM s Performance data of a new 248 nm CD metrology tool proved on COG reticles and PSM s Gerhard Schlueter a, Walter Steinberg a, John Whittey b a Leica Microsystems Wetzlar GmbH Ernst-Leitz-Str. 17-37, D-35578

More information

Calibration Report. Short Version. UltraCam Eagle, S/N UC-E f210. Vexcel Imaging GmbH, A-8010 Graz, Austria

Calibration Report. Short Version. UltraCam Eagle, S/N UC-E f210. Vexcel Imaging GmbH, A-8010 Graz, Austria Calibration Report Short Version Camera: Manufacturer: Date of Calibration: Date of Report: Revision of Camera: Version of Report: UltraCam Eagle, S/N UC-E-1-00518105-f210 Vexcel Imaging GmbH, A-8010 Graz,

More information

ECEN 4606, UNDERGRADUATE OPTICS LAB

ECEN 4606, UNDERGRADUATE OPTICS LAB ECEN 4606, UNDERGRADUATE OPTICS LAB Lab 2: Imaging 1 the Telescope Original Version: Prof. McLeod SUMMARY: In this lab you will become familiar with the use of one or more lenses to create images of distant

More information

Calibration Report. Short Version. UltraCam L, S/N UC-L Vexcel Imaging GmbH, A-8010 Graz, Austria

Calibration Report. Short Version. UltraCam L, S/N UC-L Vexcel Imaging GmbH, A-8010 Graz, Austria Calibration Report Short Version Camera: Manufacturer: UltraCam L, S/N UC-L-1-00612089 Vexcel Imaging GmbH, A-8010 Graz, Austria Date of Calibration: Mar-23-2010 Date of Report: May-17-2010 Camera Revision:

More information

Reikan FoCal Aperture Sharpness Test Report

Reikan FoCal Aperture Sharpness Test Report Focus Calibration and Analysis Software Test run on: 26/01/2016 17:02:00 with FoCal 2.0.6.2416W Report created on: 26/01/2016 17:03:39 with FoCal 2.0.6W Overview Test Information Property Description Data

More information

BROADCAST ENGINEERING 5/05 WHITE PAPER TUTORIAL. HEADLINE: HDTV Lens Design: Management of Light Transmission

BROADCAST ENGINEERING 5/05 WHITE PAPER TUTORIAL. HEADLINE: HDTV Lens Design: Management of Light Transmission BROADCAST ENGINEERING 5/05 WHITE PAPER TUTORIAL HEADLINE: HDTV Lens Design: Management of Light Transmission By Larry Thorpe and Gordon Tubbs Broadcast engineers have a comfortable familiarity with electronic

More information

ABOUT RESOLUTION. pco.knowledge base

ABOUT RESOLUTION. pco.knowledge base The resolution of an image sensor describes the total number of pixel which can be used to detect an image. From the standpoint of the image sensor it is sufficient to count the number and describe it

More information

Image Formation and Capture. Acknowledgment: some figures by B. Curless, E. Hecht, W.J. Smith, B.K.P. Horn, and A. Theuwissen

Image Formation and Capture. Acknowledgment: some figures by B. Curless, E. Hecht, W.J. Smith, B.K.P. Horn, and A. Theuwissen Image Formation and Capture Acknowledgment: some figures by B. Curless, E. Hecht, W.J. Smith, B.K.P. Horn, and A. Theuwissen Image Formation and Capture Real world Optics Sensor Devices Sources of Error

More information

Lecture 20: Optical Tools for MEMS Imaging

Lecture 20: Optical Tools for MEMS Imaging MECH 466 Microelectromechanical Systems University of Victoria Dept. of Mechanical Engineering Lecture 20: Optical Tools for MEMS Imaging 1 Overview Optical Microscopes Video Microscopes Scanning Electron

More information

DPMPHOTONICS. Precision Optics Catalog. P.O. Box 3002 Vernon, CT Tel: (860) Fax: (860)

DPMPHOTONICS. Precision Optics Catalog. P.O. Box 3002 Vernon, CT Tel: (860) Fax: (860) DPMPHOTONICS Precision Optics Catalog DPMPHOTONICS P.O. Box 3002 Vernon, CT 06066. Tel: (860) 872-6573. Fax: (860) 454-4217. Welcome to DPM Photonics... Company Background DPM Photonics was founded in

More information

Optical Components - Scanning Lenses

Optical Components - Scanning Lenses Optical Components Scanning Lenses Scanning Lenses (Ftheta) Product Information Figure 1: Scanning Lenses A scanning (Ftheta) lens supplies an image in accordance with the socalled Ftheta condition (y

More information

Reikan FoCal Aperture Sharpness Test Report

Reikan FoCal Aperture Sharpness Test Report Focus Calibration and Analysis Software Reikan FoCal Sharpness Test Report Test run on: 26/01/2016 17:14:35 with FoCal 2.0.6.2416W Report created on: 26/01/2016 17:16:16 with FoCal 2.0.6W Overview Test

More information

SUPRA Optix 3D Optical Profiler

SUPRA Optix 3D Optical Profiler SUPRA Optix 3D Optical Profiler Scanning White-light Interferometric Microscope SWIM Series Applications The SUPRA Optix is the latest development in the field of Scanning White-light Interferometry. With

More information

Lecture Notes 10 Image Sensor Optics. Imaging optics. Pixel optics. Microlens

Lecture Notes 10 Image Sensor Optics. Imaging optics. Pixel optics. Microlens Lecture Notes 10 Image Sensor Optics Imaging optics Space-invariant model Space-varying model Pixel optics Transmission Vignetting Microlens EE 392B: Image Sensor Optics 10-1 Image Sensor Optics Microlens

More information

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question. Name: Class: Date: Exam 4 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Mirages are a result of which physical phenomena a. interference c. reflection

More information

ImageMaster. Worldwide Leader in MTF Testing

ImageMaster. Worldwide Leader in MTF Testing ImageMaster Worldwide Leader in MTF Testing Contents Page Overview 3 ImageMaster Series The most comprehensive line of MTF Equipment...........3 ImageMaster R&D Line................................................7

More information

Reikan FoCal Aperture Sharpness Test Report

Reikan FoCal Aperture Sharpness Test Report Focus Calibration and Analysis Software Reikan FoCal Sharpness Test Report Test run on: 10/02/2016 19:57:05 with FoCal 2.0.6.2416W Report created on: 10/02/2016 19:59:09 with FoCal 2.0.6W Overview Test

More information

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2 Quality Testing of Intraocular Lenses OptiSpheric IOL Family and WaveMaster IOL 2 LEADING TO THE FUTURE OF OPTICS Optical systems have changed the world. And they will continue to do so. TRIOPTICS is significantly

More information

Solutions: Lens Design I Part 2. Exercise 2-1: Apertures, stops and vignetting

Solutions: Lens Design I Part 2. Exercise 2-1: Apertures, stops and vignetting 2016-04-25 Prof. Herbert Gross Mateusz Oleszko, Norman G. Worku Friedrich Schiller University Jena Institute of Applied Physics Albert-Einstein-Str 15 07745 Jena Solutions: Lens Design I Part 2 Exercise

More information

Reikan FoCal Aperture Sharpness Test Report

Reikan FoCal Aperture Sharpness Test Report Focus Calibration and Analysis Software Reikan FoCal Sharpness Test Report Test run on: 27/01/2016 00:35:25 with FoCal 2.0.6.2416W Report created on: 27/01/2016 00:41:43 with FoCal 2.0.6W Overview Test

More information

Choosing the Best Optical Filter for Your Application. Georgy Das Midwest Optical Systems, Inc.

Choosing the Best Optical Filter for Your Application. Georgy Das Midwest Optical Systems, Inc. Choosing the Best Optical Filter for Your Application Georgy Das Midwest Optical Systems, Inc. Filters are a Necessity, Not an Accessory. Key Terms Transmission (%) 100 90 80 70 60 50 40 30 20 10 OUT-OF-BAND

More information

IMAGE FORMATION. Light source properties. Sensor characteristics Surface. Surface reflectance properties. Optics

IMAGE FORMATION. Light source properties. Sensor characteristics Surface. Surface reflectance properties. Optics IMAGE FORMATION Light source properties Sensor characteristics Surface Exposure shape Optics Surface reflectance properties ANALOG IMAGES An image can be understood as a 2D light intensity function f(x,y)

More information

Test procedures Page: 1 of 5

Test procedures Page: 1 of 5 Test procedures Page: 1 of 5 1 Scope This part of document establishes uniform requirements for measuring the numerical aperture of optical fibre, thereby assisting in the inspection of fibres and cables

More information

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP PROCEEDINGS OF SPIE SPIEDigitalLibrary.org/conference-proceedings-of-spie Automated asphere centration testing with AspheroCheck UP F. Hahne, P. Langehanenberg F. Hahne, P. Langehanenberg, "Automated asphere

More information

PMS Series 3D multi-sensor portal measurement machines

PMS Series 3D multi-sensor portal measurement machines PMS Series 3D multi-sensor portal measurement machines A high-end measurement machine for high precision measurement tasks providing reliable and reproducible results using the multi-sensor system. PMS

More information

Compact High Intensity Light Source

Compact High Intensity Light Source Compact High Intensity Light Source General When a broadband light source in the ultraviolet-visible-near infrared portion of the spectrum is required, an arc lamp has no peer. The intensity of an arc

More information

INTERFEROMETER VI-direct

INTERFEROMETER VI-direct Universal Interferometers for Quality Control Ideal for Production and Quality Control INTERFEROMETER VI-direct Typical Applications Interferometers are an indispensable measurement tool for optical production

More information

MicroSpot FOCUSING OBJECTIVES

MicroSpot FOCUSING OBJECTIVES OFR P R E C I S I O N O P T I C A L P R O D U C T S MicroSpot FOCUSING OBJECTIVES APPLICATIONS Micromachining Microlithography Laser scribing Photoablation MAJOR FEATURES For UV excimer & high-power YAG

More information

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design. Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design. Multi-color scanning photocoagulation takes on a new look. Integre Pro Scan

More information

Measuring systems for ironing rings and punches

Measuring systems for ironing rings and punches Measuring systems for ironing rings and punches Equipment and proven technology for precision tooling measurement in beverage can industry RINGMASTER THE MASTER TOOL FOR RING MEASURE MENT RINGMASTER provides

More information

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series Nikon's proprietary scanning-type optical interference measurement technology achieves 1pm* height resolution. * Height

More information

How-to guide. Working with a pre-assembled THz system

How-to guide. Working with a pre-assembled THz system How-to guide 15/06/2016 1 Table of contents 0. Preparation / Basics...3 1. Input beam adjustment...4 2. Working with free space antennas...5 3. Working with fiber-coupled antennas...6 4. Contact details...8

More information

Beam deflection technologies for ultra short pulse lasers June 5th, 2018

Beam deflection technologies for ultra short pulse lasers June 5th, 2018 Beam deflection technologies for ultra short pulse lasers June 5th, 2018 Agenda SCANLAB GmbH XL Scan excellishift precsys 2 SCANLAB at a Glance Worldwide leading OEM manufacturer of scan solutions for

More information

Wavelength Stabilization of HPDL Array Fast-Axis Collimation Optic with integrated VHG

Wavelength Stabilization of HPDL Array Fast-Axis Collimation Optic with integrated VHG Wavelength Stabilization of HPDL Array Fast-Axis Collimation Optic with integrated VHG C. Schnitzler a, S. Hambuecker a, O. Ruebenach a, V. Sinhoff a, G. Steckman b, L. West b, C. Wessling c, D. Hoffmann

More information

Calibration Report. UC-SXp Version of Report:

Calibration Report. UC-SXp Version of Report: Calibration Report Camera: Serial: UltraCam Xp UC-SXp-1-40719017 Calibration Date: Date of Report: Camera Revision: Version of Report: Feb-28-2018 Mar-05-2018 Rev13.00 V01 www.vexcel-imaging.com Copyright

More information

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei Key Engineering Materials Online: 005-10-15 ISSN: 166-9795, Vols. 95-96, pp 501-506 doi:10.408/www.scientific.net/kem.95-96.501 005 Trans Tech Publications, Switzerland A 3D Profile Parallel Detecting

More information

SpectroMaster. High Precision Automatic Spectrometer-Goniometer

SpectroMaster. High Precision Automatic Spectrometer-Goniometer SpectroMaster High Precision Automatic Spectrometer-Goniometer CONTENTS Overview 3 Measurement Principle 3 Error A naly sis and System Requirements 4 Goniometer Error...4 Ambient Conditions...6 Sample

More information

Nikon Rayfact IL Series

Nikon Rayfact IL Series Nikon Rayfact IL Series Features Compatible with EL Nikkor40mmF4N, 50mmF2.8N, 63mmF2.8N and 75mmF4N Lineup : 4 models New product release : NikonRayfactIL95mmF5.6N * 4 models cover a wide range of magnification

More information

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2 Quality Testing of Intraocular Lenses OptiSpheric IOL Family and WaveMaster IOL 2 LEADING TO THE FUTURE OF OPTICS Optical systems have changed the world. And they will continue to do so. TRIOPTICS is significantly

More information

Gentec Electro-Optics, Inc

Gentec Electro-Optics, Inc Gentec Electro-Optics, Inc. 2013. Accessories for Beam Diagnostics Revision 1.2 2 WARRANTY The Gentec-EO accessories for beam diagnostics carry a one-year warranty (from date of shipment) against material

More information

Supplementary Materials

Supplementary Materials Supplementary Materials In the supplementary materials of this paper we discuss some practical consideration for alignment of optical components to help unexperienced users to achieve a high performance

More information

An Indian Journal FULL PAPER. Trade Science Inc. Parameters design of optical system in transmitive star simulator ABSTRACT KEYWORDS

An Indian Journal FULL PAPER. Trade Science Inc. Parameters design of optical system in transmitive star simulator ABSTRACT KEYWORDS [Type text] [Type text] [Type text] ISSN : 0974-7435 Volume 10 Issue 23 BioTechnology 2014 An Indian Journal FULL PAPER BTAIJ, 10(23), 2014 [14257-14264] Parameters design of optical system in transmitive

More information

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy Bi177 Lecture 5 Adding the Third Dimension Wide-field Imaging Point Spread Function Deconvolution Confocal Laser Scanning Microscopy Confocal Aperture Optical aberrations Alternative Scanning Microscopy

More information

Opto Engineering S.r.l.

Opto Engineering S.r.l. TUTORIAL #1 Telecentric Lenses: basic information and working principles On line dimensional control is one of the most challenging and difficult applications of vision systems. On the other hand, besides

More information

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax:

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax: Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore 658079 Tel: +65 63167112 Fax: +65 63167113 High-power Nd:YAG Self-floating Laser Cutting Head We supply the laser

More information

Shaping light in microscopy:

Shaping light in microscopy: Shaping light in microscopy: Adaptive optical methods and nonconventional beam shapes for enhanced imaging Martí Duocastella planet detector detector sample sample Aberrated wavefront Beamsplitter Adaptive

More information