Double Emulsion Chip (100 μm etch depth), water-oil-water Part No

Size: px
Start display at page:

Download "Double Emulsion Chip (100 μm etch depth), water-oil-water Part No"

Transcription

1 Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0) F: +44 (0) E: W: Dolomite Microfluidics North America Office Blacktrace Inc, 29 Albion Place Charlestown, MA 02129, USA C: T: F: E: Double Emulsion Chip (100 μm etch depth), water-oil-water Part No product datasheet page Description 2 Benefits 2 Specifications 3 Sealing Interface 3 Geometry 4 Surface Coatings 4 Droplet Formation 5 Custom Options 5 Optical Transmission 6 The Dolomite Centre Limited Page 1 of 7

2 Description Featuring both a fluorophilic capillary and hydrophilic flow focussing droplet junction, this glass microfluidic chip enables the formation of water-in-oil-in-water droplets ranging from 80 to 150μm (outer) and 50 to 140μm (inner) in diameter. Applications include drug delivery, high throughput screening, food based emulsions and bio-analytical studies. The Double Emulsion Chip (100μm etch depth), W/O/W is compatible with the Linear Connector 7-way (Part No ) and the H Interface 7-way (11.25mm) (Part No ) for quick and reliable fluidic connection from tubing to chip. Left: Double Emulsion Chip (100 μm etch depth), W/O/W (Part No ) Top Right: Double emulsion of water-in-oil-in-water formed in Double Emulsion Chip (100 μm etch depth), W/O/W (Part No ) Bottom Left: Microscope image of double emulsion droplets with an outer diameter of 100μm Benefits Features a fluorophilic capillary and hydrophilic flow focusing droplet junction Rapid generation of water-in-oil-in-water droplets in the size range of 80 to 150μm (outer droplet) and 50 to 140μm (inner droplet) in diameter Ideal for producing and analysing micro-emulsions Excellent chemical compatibility High visibility (excellent access for optics) Compatible with Dolomite Multiflux Linear Connectors 7-way for quick and reliable fluidic connection MAR V.A.9 Page 2 of 7

3 Specifications Specification Channel cross-section at junction (depth x width) Wide channel cross-section (depth x width) Droplet size range Capillary Surface Chip Surface Double Emulsion Chip (100μm etch depth), W/O/W (Part No ) 100μm x 105μm 100μm x 300μm Outer droplet: Ø μm Inner droplet: Ø μm Fluorophilic Hydrophilic Number of inputs 5 Number of outputs 1 Chip size (length x width x thickness) Chip top and base layer thickness Channel length after junction Surface roughness of channels (Ra) Max. operating pressure Material Fabrication 11.25mm x 15.0mm x 4mm 2.0mm 6mm 5nm up to 30bar Glass (chip), Fused Silica (capillary) HF etching and thermal bonding Sealing Interface Connector body (PEEK) Seal Glass microfluidic chip Connector tubing PTFE, FEP Microchannel MAR V.A.9 Page 3 of 7

4 Geometry Channel at junction Wide channel 100µm 100µm 105µm 300µm Surface Coatings The glass channel surface is naturally hydrophilic. Fluorophilic coating has been applied to the fused silica capillary. This enables a sheath flow of water-in-oil to be formed, which allow droplets of water-in-oil-in-water to be created at the junction. Fluorophilically coated capillary Hydrophilic chip surface Water-in-Oil-in-Water Droplets Capillary ends at this point, enabling a sheathed droplet to be created at the junction MAR V.A.9 Page 4 of 7

5 Droplet Formation The size, consistency, and production rate of droplet formation is a function of several physical parameters, including: Channel size Viscosity and surface tension of the various fluids Presence of surfactants Miscibility of the fluids Use of hydrophobic or hydrophilic coating on the channel walls Total flow rate and relative flow rate of each fluid Flow stability To accelerate development work in droplet microfluidics, Dolomite offers a range of modular micro droplet systems featuring Dolomite s industry leading microfluidic pumps, connectors and chips. The Droplet Advanced System is recommended for use with the small droplet chip for optimum results. This features the Mitos P-Pump, which provides stable, pulse-free flow for generation of droplets with extremely consistent diameters (monodisperse). Please contact Dolomite to configure a droplet system that fits your requirements. Mitos P-Pump, Flow Resistors and Droplet Chips featured in the Droplet Advanced System Custom Options Other chip configurations are available on request. If you would like to generate droplets of a different size, operate with challenging fluids or perform complex droplet functions, Dolomite can design the junction geometry required. The range of Dolomite services available covers all aspects of the development process from characterization of liquids for droplet generation to the design of commercial instruments in the field of droplet microfluidics. Please contact Dolomite to discuss your application. MAR V.A.9 Page 5 of 7

6 Transmittance, % The Dolomite Centre Ltd Optical Transmission Spectral Transmittance of 2mm glass layer Wavelength, nm Optical Transmission of Glass MAR V.A.9 Page 6 of 7

7 MAR V.A.9 Page 7 of 7

Small Droplet Chips. product datasheet

Small Droplet Chips. product datasheet Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Small

More information

Droplet Junction Chips

Droplet Junction Chips Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite

More information

3D flow focusing chips

3D flow focusing chips Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite

More information

Mitos P-Pump Droplet Monodispersity

Mitos P-Pump Droplet Monodispersity Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite

More information

Droplet Pillar Merger Chip

Droplet Pillar Merger Chip Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite

More information

Asia Microreactors Datasheet

Asia Microreactors Datasheet System : Asia Module : Microreactors Version :.0 Date : 7 th February 0 Created/ Revised by : Maxime Drobot Asia Microreactors Datasheet This document provides specifications and information for Syrris

More information

2-10 µm Diameter Water Droplets in Mineral Oil Emulsion Production

2-10 µm Diameter Water Droplets in Mineral Oil Emulsion Production 2-10 µm Diameter Water s in Mineral Oil Emulsion Production Dolomite s Generation System - Small s Application Note Page SHPT-487168127-264_v.2.0 Summary 2 Flow Focussing Based Production 3 Experimental

More information

A guide to droplet generation

A guide to droplet generation A guide to droplet generation 2 Contents INTRODUCTION... 4 Droplet generators... 4 A choice of designs... 4 DROPLET GENERATION... 5 Droplet generator geometry... 5 Flow rate control... 5 Droplet sizes

More information

Droplets Generation with 3D Printed Chip

Droplets Generation with 3D Printed Chip Droplets Generation with 3D Printed Chip A COC 3D printed microfluidic chip for the production of monodisperse droplets Application Note Page Summary 2 Microfluidic chip design 3 Experimental setup 5 Results

More information

EZ Drop Data sheet: Fluigent Droplet Kit P/N: Dropkit01

EZ Drop Data sheet: Fluigent Droplet Kit P/N: Dropkit01 EZ Drop Data sheet: Fluigent Droplet Kit /N: Dropkit01 Table of Contents 1. Description:... 3 2. Benefits:...3 3. Elements in the Fluigent Droplet kit:.....3 4. System specifications:...4 5. End production

More information

fluidic factory preview» preview» preview modular 3D printer for fluidically sealed devices Microfluidic devices in minutes for as little as $1 each

fluidic factory preview» preview» preview modular 3D printer for fluidically sealed devices Microfluidic devices in minutes for as little as $1 each fluidic factory modular 3D printer for fluidically sealed devices preview» preview» preview Microfluidic devices in minutes for as little as $1 each fluidic factory» overview Fluidic Factory is the world

More information

Print microfluidic devices in minutes for as little as $1 each.

Print microfluidic devices in minutes for as little as $1 each. Print microfluidic devices in minutes for as little as $1 each www.dolomite-microfluidics.com fluidic factory» overview Fluidic Factory is the world s first commercially available 3D printer for quick

More information

Fluidic Factory Layer Offset Function

Fluidic Factory Layer Offset Function Fluidic Factory Layer Offset Function Use of layer offset function to print on top of COC transparent substrate Application Note Page Aim & Objectives 1 Introduction 1 Layer Offset Function (Case Study)

More information

A Novel Surgery-like Strategy for Droplet Coalescence in Microchannels

A Novel Surgery-like Strategy for Droplet Coalescence in Microchannels Supplementary Material (ESI) for Lab on a Chip A Novel Surgery-like Strategy for Droplet Coalescence in Microchannels Supplementary material Nan-Nan Deng, a Shao-Xing Sun, a Wei Wang, a Xiao-Jie Ju, a

More information

The Research on Biosynsphere Damage Analysis Based on 3D Vessel Bioprinter

The Research on Biosynsphere Damage Analysis Based on 3D Vessel Bioprinter International Conference on Mechatronics Engineering and Information Technology (ICMEIT 6) The Research on Biosynsphere Damage Analysis Based on 3D Vessel Bioprinter Huanbao Liua, Huixing Zhoub, Haiming

More information

Droplet on Demand Generation and Pairwise Merging

Droplet on Demand Generation and Pairwise Merging Droplet on Demand Generation and Pairwise Merging Mitos Dropix Droplet Merging System Application Note Page Summary 2 Mitos Dropix Technology 4 Modes of Operation 5 Test Setup 6 Results 7 Merging Phase

More information

Fluidic Factory Pause Function

Fluidic Factory Pause Function Fluidic Factory Pause Function Use of pause function for the design of a flow cell for electrochemical sensor testing Application Note Page Aim & Objectives 1 Introduction 1 Pause Function (Case of Study)

More information

We thank Reviewer 1 for their close read and positive assessment of our work.

We thank Reviewer 1 for their close read and positive assessment of our work. Reviewers' Comments: Reviewer #1: Remarks to the Author: This paper reports a highly parallelized microfluidic device made of silicon and glass that produces micrometer-sized drops with a narrow size distribution.

More information

Mitos Dropix Droplet Generation System

Mitos Dropix Droplet Generation System Mitos Dropix Droplet Generation System Demonstration of Droplet-on-Demand Sequencing (Mode 1) Application Note Page Mitos Dropix Technology 2 Abstract 3 Modes of Operation 4 Setup 5 Results 8 Conclusion

More information

USER MANUAL VarioS-Microscanner-Demonstrators

USER MANUAL VarioS-Microscanner-Demonstrators FRAUNHOFER INSTITUTE FOR PHOTONIC MICROSYSTEMS IPMS USER MANUAL VarioS-Microscanner-Demonstrators last revision : 2014-11-14 [Fb046.08] USER MANUAL.doc Introduction Thank you for purchasing a VarioS-microscanner-demonstrator

More information

COMPACT Diode Laser System (Water-Cooled)

COMPACT Diode Laser System (Water-Cooled) COMPACT Diode Laser System (Water-Cooled) Easy-to-integrate CW system consists of a compact 19 (11HU including water-air-chiller), rack-mountable chassis and metal-armored fiber. Can be combined with DILAS

More information

Supplementary Figure S1. Schematic representation of different functionalities that could be

Supplementary Figure S1. Schematic representation of different functionalities that could be Supplementary Figure S1. Schematic representation of different functionalities that could be obtained using the fiber-bundle approach This schematic representation shows some example of the possible functions

More information

The Laser Processing of Diamond and Sapphire

The Laser Processing of Diamond and Sapphire The Laser Processing of Diamond and Sapphire Neil Sykes Micronanics Limited neil@micronanics.com Diamond Diamond has the highest hardness and thermal conductivity of any bulk material 10/10 on the Mohs

More information

Simulation of the Dynamic Behaviour of a Droplet on a Structured Surface using the Non-conservative Level Set Method

Simulation of the Dynamic Behaviour of a Droplet on a Structured Surface using the Non-conservative Level Set Method Excerpt from the Proceedings of the COMSOL Conference 2008 Hannover Simulation of the Dynamic Behaviour of a Droplet on a Structured Surface using the Non-conservative Level Set Method N. Boufercha* 1,

More information

Laser Processing of Quartz for Microfluidic Device Fabrication

Laser Processing of Quartz for Microfluidic Device Fabrication Laser Processing of Quartz for Microfluidic Device Fabrication A. Ben Azourt 2, M. Vazquezt 1, B. Paullt 1, and D. Brabazon 2 l lrish Separation Science Cluster, National Centre for Sensor Research, Dublin

More information

Plan Optik AG. Plan Optik AG PRODUCT CATALOGUE

Plan Optik AG. Plan Optik AG PRODUCT CATALOGUE Plan Optik AG Plan Optik AG PRODUCT CATALOGUE 2 In order to service the high demand of wafers more quickly, Plan Optik provides off the shelf products in sizes from 2 up to 300mm diameter. Therefore Plan

More information

Laser Diode Bar Assemblies

Laser Diode Bar Assemblies Product Division Laser Diode Bar Assemblies Product PH-800-QCW Description 800W QCW pumping power, Ø3mm rod Main Features This compact laser pumping head consists of six water-cooled diode laser bars arranged

More information

Photonic Crystal Fiber Interfacing. In partnership with

Photonic Crystal Fiber Interfacing. In partnership with Photonic Crystal Fiber Interfacing In partnership with Contents 4 Photonics Crystal Fibers 6 End-capping 8 PCF connectors With strong expertise in designing fiber lasers and fused fiber components, ALPhANOV,

More information

Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors

Micro-sensors - what happens when you make classical devices small: MEMS devices and integrated bolometric IR detectors Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors Dean P. Neikirk 1 MURI bio-ir sensors kick-off 6/16/98 Where are the targets

More information

Just where it s needed

Just where it s needed Seite/Page: 1 Just where it s needed Continuing miniaturisation of many products requires a method of dispensing very small amounts of liquids Inkjet technology is capable of applying adhesives and many

More information

Introduction to Microfluidics. C. Fütterer, Institut Curie & Fluigent SA, Paris

Introduction to Microfluidics. C. Fütterer, Institut Curie & Fluigent SA, Paris Introduction to Microfluidics C. Fütterer, Institut Curie & Fluigent SA, Paris Miniaturisation & Integration Micro-Pipettes Problems: Minimal volume: 1μl Samples unprotected against evaporation & contamination

More information

Typical LED Characteristics

Typical LED Characteristics Typical LED Characteristics Characteristic Unit Value Light output 1 mw > 1 2 Peak wavelength 3 nm 255 nm to 28 nm 4 Viewing angle Degrees 11 5 Full width at half maximum 3 (@1 ma) nm 16 Forward voltage

More information

Technical data sheet. Encapsulator B-390 / B-395 Pro

Technical data sheet. Encapsulator B-390 / B-395 Pro Encapsulator B-390 / B-395 Pro Technical data sheet Production of functionalized beads and core-shell capsules with narrow size distribution are the key benefits of this system. BUCHI offers the Encapsulator

More information

OPTOFLUIDIC ULTRAHIGH-THROUGHPUT DETECTION OF FLUORESCENT DROPS. Electronic Supplementary Information

OPTOFLUIDIC ULTRAHIGH-THROUGHPUT DETECTION OF FLUORESCENT DROPS. Electronic Supplementary Information Electronic Supplementary Material (ESI) for Lab on a Chip. This journal is The Royal Society of Chemistry 2015 OPTOFLUIDIC ULTRAHIGH-THROUGHPUT DETECTION OF FLUORESCENT DROPS Minkyu Kim 1, Ming Pan 2,

More information

Influence of abrasive material on abrasive waterjet cutting process

Influence of abrasive material on abrasive waterjet cutting process Influence of abrasive material on abrasive waterjet cutting process I. A. Perianu, D. Ionescu, C. Ciucă National R&D Institute for Welding and Material Testing - ISIM Timişoara, Romania E-mail: aperianu@isim.ro

More information

True Three-Dimensional Interconnections

True Three-Dimensional Interconnections True Three-Dimensional Interconnections Satoshi Yamamoto, 1 Hiroyuki Wakioka, 1 Osamu Nukaga, 1 Takanao Suzuki, 2 and Tatsuo Suemasu 1 As one of the next-generation through-hole interconnection (THI) technologies,

More information

Drivetrain for Vehicles 2018

Drivetrain for Vehicles 2018 Drivetrain for Vehicles 2018 presentation of an innovation RoBoC = Roll Bond Core ADVANTAGES OFFER RoBoC - Keep the stator housing battery housing power unit housing junction box and other similar applications

More information

An Implantable Microfluidic Device for Self Monitoring of Intraocular Pressure

An Implantable Microfluidic Device for Self Monitoring of Intraocular Pressure An Implantable Microfluidic Device for Self Monitoring of Intraocular Pressure 1,2 Ismail E. Araci, 1 Baolong Su, 1-3 Stephen R. Quake *, 4-6 Yossi Mandel * 1 Department of Bioengineering, Stanford University,

More information

The LINOS Singlets. Our quality criteria:

The LINOS Singlets. Our quality criteria: The LINOS From convergent lenses and diffuse lenses to best form lenses and aspheres, our extensive selection of simple lenses, or singlets, with various focal lengths and diameters guarantees that you

More information

German Photonics Industry - Products & Innovations SPIE Photonics West Exhibition, 5-7 February 2013

German Photonics Industry - Products & Innovations SPIE Photonics West Exhibition, 5-7 February 2013 Laser Technology, Research and Development Contact person for the media Steffen Böhme Tapering of different optical components with CO 2-laser Laser based tapering overcomes typical limitations of conventional

More information

MicCell Product Overview

MicCell Product Overview Easy-to-Use Microperfusion System Versatile, modular, expandable perfusion system with microchannels made of polymer, glass or silicon All peripherals (i.e. pumps, tubes, fittings) are reused, making it

More information

Coating of Si Nanowire Array by Flexible Polymer

Coating of Si Nanowire Array by Flexible Polymer , pp.422-426 http://dx.doi.org/10.14257/astl.2016.139.84 Coating of Si Nanowire Array by Flexible Polymer Hee- Jo An 1, Seung-jin Lee 2, Taek-soo Ji 3* 1,2.3 Department of Electronics and Computer Engineering,

More information

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design TECHNICAL NOTE 43333 Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design Keywords Optical design, Polychromator, Spectrometer Key Benefits The Thermo Scientific icap 7000

More information

Pitch Reducing Optical Fiber Array Two-Dimensional (2D)

Pitch Reducing Optical Fiber Array Two-Dimensional (2D) PROFA Pitch Reducing Optical Fiber Array Two-Dimensional (2D) Pitch Reducing Optical Fiber Arrays (PROFAs) provide low loss coupling between standard optical fibers and photonic integrated circuits. Unlike

More information

How an ink jet printer works

How an ink jet printer works How an ink jet printer works Eric Hanson Hewlett Packard Laboratories Ink jet printers are the most common type of printing devices used in home environments, and they are also frequently used personal

More information

Unpolarized Cluster, Jet and Pellet Targets

Unpolarized Cluster, Jet and Pellet Targets Unpolarized Cluster, Jet and Pellet Targets Intense Electron Beams Workshop Cornell University, June 17-19, 2015 Institut für Kernphysik Typical Requirements on Internal Targets Target material: H 2, D

More information

Drop-on-Demand Inkjet Printing of Liquid Crystals for Photonics Applications

Drop-on-Demand Inkjet Printing of Liquid Crystals for Photonics Applications Drop-on-Demand Inkjet Printing of Liquid Crystals for Photonics Applications Ellis Parry, Steve Elston, Alfonson Castrejon-Pita, Serena Bolis and Stephen Morris PhD Student University of Oxford Drop-on

More information

Development of a Digital Micropump with Controlled Flow Rate for Microfluidic Platforms

Development of a Digital Micropump with Controlled Flow Rate for Microfluidic Platforms Sensors & Transducers 2014 by IFSA Publishing, S. L. http://www.sensorsportal.com Development of a Digital Micropump with Controlled Flow Rate for Microfluidic Platforms Mohammad Paknahad, Hojatollah Rezaei

More information

Laser Speckle Reducer LSR-3000 Series

Laser Speckle Reducer LSR-3000 Series Laser Speckle Reducer LSR-3000 Series Speckle noise from a laser-based system is reduced by dynamically diffusing the laser beam. A diffuser is bonded to a thin elastic membrane, which includes four independent

More information

Screen Making For Membrane Switches

Screen Making For Membrane Switches Screen Making For Membrane Switches By Wolfgang Pfirrmann, KIWO Inc. Printing membrane switches requires skill and control over the process. This industry has set fairly tight quality standards in regard

More information

Study on Deep Electrochemical Etching with Laser assistance technology for medical devices

Study on Deep Electrochemical Etching with Laser assistance technology for medical devices IWMF214, 9 th INTERNATIONAL WORKSHOP ON MICROFACTORIES OCTOBER 5-8, 214, HONOLULU, U.S.A. / 1 Study on Deep Electrochemical Etching with Laser assistance technology for medical devices Taiki Yamane 1,

More information

MicroSpot FOCUSING OBJECTIVES

MicroSpot FOCUSING OBJECTIVES OFR P R E C I S I O N O P T I C A L P R O D U C T S MicroSpot FOCUSING OBJECTIVES APPLICATIONS Micromachining Microlithography Laser scribing Photoablation MAJOR FEATURES For UV excimer & high-power YAG

More information

Flow-Cell FC200S+ OCCHIO. The best solution for measuring suspensions,emulsions and foams

Flow-Cell FC200S+ OCCHIO. The best solution for measuring suspensions,emulsions and foams Y o u n e e d p r e c i s i o n, y o u w a n t m o r p h o l o g y OCCHIO Flow-Cell FC200S+ The best solution for measuring suspensions,emulsions and foams OCCHIO C C H I O Pharma F l o w - C e l l FC200S+

More information

Advances in Laser Micro-machining for Wafer Probing and Trimming

Advances in Laser Micro-machining for Wafer Probing and Trimming Advances in Laser Micro-machining for Wafer Probing and Trimming M.R.H. Knowles, A.I.Bell, G. Rutterford & A. Webb Oxford Lasers June 10, 2002 Oxford Lasers June 2002 1 Introduction to Laser Micro-machining

More information

Micromachining of complex channel systems in 3D quartz substrates using Q-switched Nd:YAG laser

Micromachining of complex channel systems in 3D quartz substrates using Q-switched Nd:YAG laser Appl. Phys. A 74, 773 777 (2002)/ Digital Object Identifier (DOI) 10.1007/s003390100943 Applied Physics A Materials Science & Processing Micromachining of complex channel systems in 3D quartz substrates

More information

MEMS-based Micro Coriolis mass flow sensor

MEMS-based Micro Coriolis mass flow sensor MEMS-based Micro Coriolis mass flow sensor J. Haneveld 1, D.M. Brouwer 2,3, A. Mehendale 2,3, R. Zwikker 3, T.S.J. Lammerink 1, M.J. de Boer 1, and R.J. Wiegerink 1. 1 MESA+ Institute for Nanotechnology,

More information

Droplet formation by rupture of vibration-induced interfacial

Droplet formation by rupture of vibration-induced interfacial Supporting Information for Droplet formation by rupture of vibration-induced interfacial fingers Sze Yi Mak 1,2, Youchuang Chao 1,2, Shakurur Rahman 1 and Ho Cheung Shum 1,2,* 1 Department of Mechanical

More information

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Process Automation. Sensors and Systems:   Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable,

More information

Hermetic Packaging Solutions using Borosilicate Glass Thin Films. Lithoglas Hermetic Packaging Solutions using Borosilicate Glass Thin Films

Hermetic Packaging Solutions using Borosilicate Glass Thin Films. Lithoglas Hermetic Packaging Solutions using Borosilicate Glass Thin Films Hermetic Packaging Solutions using Borosilicate Glass Thin Films 1 Company Profile Company founded in 2006 ISO 9001:2008 qualified since 2011 Headquarters and Production in Dresden, Germany Production

More information

Compressed-air flow control system

Compressed-air flow control system Supplementary Information Supplementary Material (ESI) for Lab on a Chip Compressed-air flow control system Ki Wan Bong a, Stephen C. Chapin a, Daniel C. Pregibon b, David Baah c, Tamara M. Floyd-Smith

More information

Micro Precision Apertures

Micro Precision Apertures National Aperture, Inc. Micro Precision Apertures Product Guide Precision apertures, targets and patterns, including round, slit, square, etc., for universal and high power applications National Aperture,

More information

Where Art & Science Come Together.

Where Art & Science Come Together. Accu-Glass Since 1960, Accu-Glass has been dedicated exclusively to the engineering and manufacturing of precision glass tube products. Our numerous clients in the medical, laboratory, Point-of-Care, fiber

More information

ADHEBIT Adhesion Promoters

ADHEBIT Adhesion Promoters ADHEBIT Adhesion Promoters A new generation of adhesion promoters that combines superior coating and exceptional workability with immediate commercial saving The life of an asphalt pavement depends basically

More information

k λ NA Resolution of optical systems depends on the wavelength visible light λ = 500 nm Extreme ultra-violet and soft x-ray light λ = 1-50 nm

k λ NA Resolution of optical systems depends on the wavelength visible light λ = 500 nm Extreme ultra-violet and soft x-ray light λ = 1-50 nm Resolution of optical systems depends on the wavelength visible light λ = 500 nm Spatial Resolution = k λ NA EUV and SXR microscopy can potentially resolve full-field images with 10-100x smaller features

More information

Using new international patented production technologies for polymer mems and high-integrated systems

Using new international patented production technologies for polymer mems and high-integrated systems Using new international patented production technologies for polymer mems and high-integrated systems Micromechanics, MEMS, Plastic Lab-on-a-chip Production Service, Packaging and R&D Advanced Micro- and

More information

Stability of Food Emulsions (2)

Stability of Food Emulsions (2) Stability of Food Emulsions (2) David Julian McClements Biopolymers and Colloids Laboratory Department of Food Science Droplet Coalescence Oiling Off Coalescence Aggregation due to fusing together of two

More information

Wirelessly powered micro-tracer enabled by miniaturized antenna and microfluidic channel

Wirelessly powered micro-tracer enabled by miniaturized antenna and microfluidic channel Journal of Physics: Conference Series PAPER OPEN ACCESS Wirelessly powered micro-tracer enabled by miniaturized antenna and microfluidic channel To cite this article: G Duan et al 2015 J. Phys.: Conf.

More information

Morphology of printed lines and droplet deposits using hydrophilic nanoparticle suspensions. By Jim Lyon REU Advisor Professor Megaridis

Morphology of printed lines and droplet deposits using hydrophilic nanoparticle suspensions. By Jim Lyon REU Advisor Professor Megaridis Morphology of printed lines and droplet deposits using hydrophilic nanoparticle suspensions By Jim Lyon REU Advisor Professor Megaridis Background Printed lines containing micro-particles are used in development

More information

UV COBRA Slim Supplementary information

UV COBRA Slim Supplementary information Supplementary information Key Features Design: Slim and compact Field adjustable: focussing distance and diffusers Chip-on-Board: Extreme brightness and high uniformity Crystal Clear Line Scan Images COBRA

More information

EHD2. Ultra Thin Film Measurement System

EHD2. Ultra Thin Film Measurement System EHD2 Ultra Thin Film Measurement System A fully automated bench top, computer controlled instrument for film thickness measurements of lubricants in the elastohydrodynamic (EHD) lubricating regime EHD2

More information

Rapid and inexpensive fabrication of polymeric microfluidic devices via toner transfer masking

Rapid and inexpensive fabrication of polymeric microfluidic devices via toner transfer masking Easley et al. Toner Transfer Masking Page -1- B816575K_supplementary_revd.doc December 3, 2008 Supplementary Information for Rapid and inexpensive fabrication of polymeric microfluidic devices via toner

More information

Precision Micro-Aperture Catalog

Precision Micro-Aperture Catalog National Aperture, Inc. Precision Micro-Aperture Catalog Version 2012 PLEASE CONTACT: Data Optics, Inc. Distributor for National Aperture, Inc. Phone: (734) 483-8228 (800) 321-9026 Fax: (734) 483-9879

More information

Inkjet Printing of Ag Nanoparticles using Dimatix Inkjet Printer, No 1

Inkjet Printing of Ag Nanoparticles using Dimatix Inkjet Printer, No 1 University of Pennsylvania ScholarlyCommons Protocols and Reports Browse by Type 1-13-2017 using Dimatix Inkjet Printer, No 1 Amal Abbas amalabb@seas.upenn.edu Inayat Bajwa inabajwa@seas.upenn.edu Follow

More information

DROP SHAPE ANALYZER DSA100 THE VERSATILE HIGH-END INSTRUMENT FOR ANALYZING COATING AND WETTING PROCESSES

DROP SHAPE ANALYZER DSA100 THE VERSATILE HIGH-END INSTRUMENT FOR ANALYZING COATING AND WETTING PROCESSES DROP SHAPE ANALYZER DSA100 THE VERSATILE HIGH-END INSTRUMENT FOR ANALYZING COATING AND WETTING PROCESSES PRECISION AND PERFECTION QUITE AUTOMATICALLY Options for complete software-controlled surface analysis

More information

PRELIMINARY. EL-6-18-VIS-LD Dimensions (L x W x H) 18 x 19.3 x 8.7 mm Clear aperture 6 mm Weight 6.7 g Lifecycles (10-90% sinusoidal) >

PRELIMINARY. EL-6-18-VIS-LD Dimensions (L x W x H) 18 x 19.3 x 8.7 mm Clear aperture 6 mm Weight 6.7 g Lifecycles (10-90% sinusoidal) > Fast EL-6-18 The curvature of this shape changing polymer lens can be adjusted by applying current. The focal length is accordingly tuned to a desired value within milliseconds. The following table outlines

More information

Thermal Conductivity Sensor for Leak or Pressure Detection MTCS2601. MTCS2601 silicon sensing die in SMD ceramic package

Thermal Conductivity Sensor for Leak or Pressure Detection MTCS2601. MTCS2601 silicon sensing die in SMD ceramic package Sensor Description Thermal Conductivity Sensor for Leak or Pressure Detection MTCS2601 MTCS2601 silicon sensing die in SMD ceramic package Thermal conductivity sensor for primary vacuum measurement Silicon

More information

Lecture 22 Optical MEMS (4)

Lecture 22 Optical MEMS (4) EEL6935 Advanced MEMS (Spring 2005) Instructor: Dr. Huikai Xie Lecture 22 Optical MEMS (4) Agenda: Refractive Optical Elements Microlenses GRIN Lenses Microprisms Reference: S. Sinzinger and J. Jahns,

More information

The thin wall ESI tip appears unusually. advantageous for ensuring stable ESI. conditions and efficient ion transfers.

The thin wall ESI tip appears unusually. advantageous for ensuring stable ESI. conditions and efficient ion transfers. The thin wall ESI tip appears unusually advantageous for ensuring stable ESI conditions and efficient ion transfers. Valaskovic, Kelleher, McLafferty Science (1996), 273, 1199 perfect zero-dead-volume

More information

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range TM B r e a k t h r o u g h F l o wmeter Technology Ultrasonic Flowmeter Range IDEAL FOR: Drink dispensing Laboratory tests Cooling equipment Active flow alarms Semiconductor plant OEM applications Pilot

More information

Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position

Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position 2 optoncdt 2401 Confocal displacement measurement system - Non-contact measurement principle

More information

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications Part I: RF Applications Introductions and Motivations What are RF MEMS? Example Devices RFIC RFIC consists of Active components

More information

UVISEL. Spectroscopic Phase Modulated Ellipsometer. The Ideal Tool for Thin Film and Material Characterization

UVISEL. Spectroscopic Phase Modulated Ellipsometer. The Ideal Tool for Thin Film and Material Characterization UVISEL Spectroscopic Phase Modulated Ellipsometer The Ideal Tool for Thin Film and Material Characterization High Precision Research Spectroscopic Ellipsometer The UVISEL ellipsometer offers the best combination

More information

Section IX: AF Series Fibers and Fiber Couplers

Section IX: AF Series Fibers and Fiber Couplers Section IX: AF Series Fibers and Fiber SPECTRAL PRODUCTS AF Series Fiber Optic Assemblies Bifurcated Bundles SingleCore Fibers Fiber Bundles Liquid Guides AFCM Series Direct Coupling Fiber Optic Adapters

More information

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax:

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax: Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore 658079 Tel: +65 63167112 Fax: +65 63167113 High-power Nd:YAG Self-floating Laser Cutting Head We supply the laser

More information

CHAPTER 7. Components of Optical Instruments

CHAPTER 7. Components of Optical Instruments CHAPTER 7 Components of Optical Instruments From: Principles of Instrumental Analysis, 6 th Edition, Holler, Skoog and Crouch. CMY 383 Dr Tim Laurens NB Optical in this case refers not only to the visible

More information

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16 Technical Information TI 7C//ae Conductivity Measuring Cells for High-Temperature Applications Two-electrode measuring sensors with fixed cable or connector version with integrated temperature sensor Cell

More information

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations PAGE 88 & 2008 2007 PRODUCT CATALOG CRYOGENIC PROBE STATION fundamentals...................... 90 principles of cryogenic probe stations attocps I.......................... 92 ultra stable cryogenic probe

More information

End Capped High Power Assemblies

End Capped High Power Assemblies Fiberguide s end capped fiber optic assemblies allow the user to achieve higher coupled power into a fiber core by reducing the power density at the air/ silica interface, commonly the point of laser damage.

More information

Introduction of New Products

Introduction of New Products Field Emission Electron Microscope JEM-3100F For evaluation of materials in the fields of nanoscience and nanomaterials science, TEM is required to provide resolution and analytical capabilities that can

More information

PHILTEC PHILTEC FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE SOLVE YOUR MEASUREMENT PROBLEMS FIBEROPTIC SENSORS

PHILTEC PHILTEC FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE SOLVE YOUR MEASUREMENT PROBLEMS FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE PHILTEC FIBEROPTIC SENSORS SOLVE YOUR MEASUREMENT PROBLEMS PHILTEC FIBEROPTIC SENSORS DISTANCE I DISPLACEMENT I VIBRATION PRODUCT GUIDE PHILTEC A P P L I C AT I O N S Aerospace

More information

Mirrors. Plano and Spherical. Mirrors. Published on II-VI Infrared

Mirrors. Plano and Spherical. Mirrors. Published on II-VI Infrared Page 1 of 13 Published on II-VI Infrared Plano and Spherical or total reflectors are used in laser cavities as rear reflectors and fold mirrors, and externally as beam benders in beam delivery systems.

More information

Stencil Technology. Agenda: Laser Technology Stencil Materials Processes Post Process

Stencil Technology. Agenda: Laser Technology Stencil Materials Processes Post Process Stencil Technology Agenda: Laser Technology Stencil Materials Processes Post Process Laser s YAG LASER Conventional Laser Pulses Laser beam diameter is 2.3mil Ridges in the inside walls of the apertures

More information

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004 Lithography 3 rd lecture: introduction Prof. Yosi Shacham-Diamand Fall 2004 1 List of content Fundamental principles Characteristics parameters Exposure systems 2 Fundamental principles Aerial Image Exposure

More information

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold 1354 MINIS Oriel Integrating Spheres Integrating spheres are ideal optical diffusers; they are used for radiometric measurements where uniform illumination or angular collection is essential, for reflectance

More information

OIL AND WATER SEPARATION AT ITS BEST

OIL AND WATER SEPARATION AT ITS BEST OIL AND WATER SEPARATION AT ITS BEST Looking for faster and more efficient separation of produced water from crude oil as well as increased production? Vessel Internal Electrostatic Coalescers (VIEC) have

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Multi-step microfluidic droplet processing: kinetic analysis of an in vitro translated enzyme

Multi-step microfluidic droplet processing: kinetic analysis of an in vitro translated enzyme Supporting information to accompany the manuscript: Multi-step microfluidic droplet processing: kinetic analysis of an in vitro translated enzyme Linas Mazutis a, Jean-Christophe Baret a, Patrick Treacy

More information

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Bandpass Edge Dichroic Notch & More

Bandpass Edge Dichroic Notch & More Edmund Optics BROCHURE Filters COPYRIGHT 217 EDMUND OPTICS, INC. ALL RIGHTS RESERVED 1/17 Bandpass Edge Dichroic Notch & More Contact us for a Stock or Custom Quote Today! USA: +1-856-547-3488 EUROPE:

More information

CHIRPED FIBER BRAGG GRATING (CFBG) BY ETCHING TECHNIQUE FOR SIMULTANEOUS TEMPERATURE AND REFRACTIVE INDEX SENSING

CHIRPED FIBER BRAGG GRATING (CFBG) BY ETCHING TECHNIQUE FOR SIMULTANEOUS TEMPERATURE AND REFRACTIVE INDEX SENSING CHIRPED FIBER BRAGG GRATING (CFBG) BY ETCHING TECHNIQUE FOR SIMULTANEOUS TEMPERATURE AND REFRACTIVE INDEX SENSING Siti Aisyah bt. Ibrahim and Chong Wu Yi Photonics Research Center Department of Physics,

More information