ISIS A beginner s guide

Size: px
Start display at page:

Download "ISIS A beginner s guide"

Transcription

1 ISIS A beginner s guide Conceived of and written by Christian Buil, ISIS is a powerful astronomical spectral processing application that can appear daunting to first time users. While designed as a comprehensive pipeline for end- to- end spectral image processing, ISIS includes many advanced features that can be disregarded while becoming familiar with basic profile creation. The following beginner s guide provides a basic workflow for producing a calibrated spectral profile from a set of target and calibration images. Important this guide assumes that target and neon images have been bias and dark corrected. Functionality in ISIS for creating and applying master bias, flat and dark frames has been deliberately omitted from this guide to keep things as basic as possible. 1 File organisation ISIS utilises file organisation conventions designed to streamline processing of new spectra. It is important to take time to ensure that directory organisation and file naming requirements are understood and applied before processing files with ISIS. 1.1 Directory structure To begin with, it is assumed that you have acquired a number of spectral images in FITs format of a specific target and target wavelength and taken sequentially together with one or more calibration frames (normally a neon lamp calibration image acquired before, during or after a sequence of target images). It is best to store all images and calibration frames under a single directory. ISIS has been optimised to use a single working directory structure for file access and data output for each object and target wavelength acquired on a particular night. 1.2 File naming File conventions for spectral images in ISIS require a consistent file name and numerical sequence. A highly suggested approach is to employ a hyphen between file name and sequence number, e.g: image- 1.fit image- 2.fit image- 3.fit For example, if you have been acquiring spectra of eta Carinae on a particular night, you might have a list of images similar to the following: 1

2 C:\ \etacar- 1.fit etacar- 2.fit etacar- 3.fit etacar- 12.fit It is recommended that the same convention be used for neon calibration images. If you have acquired only one calibration image, consider naming it in a similar fashion, eg: C:\ \neonetacar- 1.fit If you ve taken neon calibration images before, during and after the target sequence, you might consider naming your neon calibration images as follows: C:\ \neonetacar- 1.fit neonetacar- 2.fit neonetacar- 3.fit (the before image) (the mid image) (the after image) Tip: ISIS includes a tool for converting MaxIM DL formatted numbering to ISIS numbering - see appendix A for information. 2

3 2 Using ISIS Section 2 provides a suggested sequence for first time processing of a sequence of spectral images in order to create a calibrated profile. It includes details on determining the spectral dispersion coefficients required for calibrating images acquired by non- Shelyak instruments. 2.1 Settings The Settings page (shown in Figure 1) serves two main purposes: Specification of default program settings. Setting the location of files for a particular session Figure 1: The ISIS Settings Page Descriptions of the numbered fields highlighted in Figure 1 are as follows: 1. Spectrograph model Unless you use and interchange a number of different Shelyak instruments, this field only needs to be set once. For non- Shelyak slit spectroscopes such as the JTW Spectra- L200, select LHIRES III. 3

4 2. Working directory Specify the location of files you wish to work on for a particular session. ISIS returns to the previously specified location on start up, so the working directory generally needs to be redefined at the commencement of processing newly acquired spectra. Organising your data by date is highly recommended. 3. Spectral database directory The spectral database directory is the location where you have installed the required database files. These can be downloaded from the ISIS web site and should be installed at the same time as ISIS. 4. GNUPLOT software directory (optional) GNUPLOT is used to create publishable plots and is optional. Leave this field blank if you have not installed GNUPLOT. 5. Observatory Specify your observatory longitude, latitude and altitude. 6. Spectral domain for profile scaling This is where the wavelength range used for flux normalisation is specified. The values chosen depend on the target characteristics and wavelength range of your spectra and can be changed at any stage during profile creation. If you are unsure, just choose a small featureless range that sits within the wavelength limits of your spectra for now. Other fields Check the language and FITs extension details. Leave the other fields set at their defaults for now. 4

5 3 Preparing for calibration Spectral dispersion coefficients need to be determined prior to target image calibration. This step is particularly relevant for non- Shelyak instruments. Dispersion coefficients are calculated using measurements undertaken on the neon calibration image taken as part of a target sequence. Once determined, the spectral dispersion coefficients remain active, even if ISIS is restarted. There are two steps to this process. 3.1 Extract a raw spectral profile from the neon calibration image. To extract a raw spectral profile from your neon image, go to the Tools page and select Spectra processing Figure 2: Extracting a raw spectral profile from the neon image Enter the name of your calibration image (omitting the extension) next to Image name. Enter a name for what will become the raw spectral file next to Profile name. Press Go. A DAT file will be created in the default directory in the example above neonetacar.dat. 5

6 3.2 Determine the spectral dispersion Select the Profile page in ISIS. ISIS beginner s guide. Version 2.0, September 2014 Figure 3: An uncalibrated neon profile Using the Open File button, select and open the previously created DAT file. An uncalibrated profile of your neon image will appear on the display. Select the Dispersion button to open the Compute spectral dispersion dialogue. If it is populated with values, press Reset. Figure 4: Spectral dispersion dialogue 6

7 The procedure at this point is to select features on the calibration profile by double clicking on each side of known emissions. ISIS automatically populates the dispersion dialogue with a precise x value. Enter the corresponding wavelength and repeat for other lines. Tip: Choose from the drop down list of magnification factors on the profile page to zoom in on the profile. Figure 5: Double click on each side of a feature and enter the wavelength Once the table is complete, the dispersion coefficients can be computed using a number of selectable polynomial functions before pressing the Compute polynom button. Finally, press Calibration to compute the coefficients and enter them into ISIS. A calibrated neon profile appears as a check and can be saved as an option. Though also not required, the lines list and polynomial information can also be saved prior to exiting the dispersion dialogue. Spectral dispersion has now been calculated and incorporated into the current project and is retained even after restarting ISIS. This feature streamlines spectral processing at the same target wavelength range on subsequent nights. In addition, the calculated spectral dispersion for this project can be reused for new projects of the same target wavelength and resolution. Appendix C and D outline the XML features present in ISIS that provide for this. 7

8 4 General The General page provides a home base for the commencement of a typical session. It may appear confusing at first, so observe the following sequence carefully: Figure 6: The ISIS General page 1. Using the file selection box adjacent to Root name, navigate to and open the first image file in your sequence using the previous example this would be, etacar- 1.fits. 2. Press the Auto button. 3. The yellow fields will be automatically populated with Generic name, Number and Calibration according to defined prefix and suffix preferences (bottom right on the General page). 4. ISIS will automatically detect the number of images according to the sequence naming convention. Check that the number of images matches what you expect. 5. Check that the file name listed next to Calibration matches your calibration file. If it doesn t, you can select the file manually using the file selection box. The example in Figure 2 assumes we are using only ONE calibration image, acquired before the target sequence. Tip: See appendix B for information on how to combine calibration frames. 6. Enter a descriptive Object name of your choosing. It is best to use an official designation to take advantage of advanced features in ISIS (not covered in this basic guide). 8

9 7. Under general parameters, ensure that pixel size matches the pixel size of your images, not your camera. For example, if you imaged at bin2, enter double that of your camera s pixel size. 8. Select Predefined dispersion equation under Spectral calibration. The previously determined dispersion coefficients will be used. 9. Enter instrument, site and observer details according to your requirements. Important: This basic guide assumes images that have already been bias and dark corrected. As a consequence, ensure that the Offset, Dark and Flat entries are empty. Finally, and as an option, edit the object and calibration prefixes and suffixes to match your desired file naming convention, keeping in mind the suggested hyphenated numerical standard used in ISIS. The file name prefix and suffix preferences are what ISIS used when you clicked on Auto in step 2, so you can experiment with these to see what ISIS finds (or doesn t find). Note all file names selected or entered into ISIS are done so with the extension omitted. 9

10 5 Calibration The final steps in producing a calibrated profile of the target are as follows: 1. Select the Calibration page in ISIS. 2. Use the brightness and contrast sliders to adjust the image so that the spectra is visible. 3. Using the mouse, select a rectangular region along the width of the spectra and press Tilt. The tilt value will automatically appear adjacent to Tilt angle (Figure 7). Figure 7: Adjusting for tilt 10

11 4. Activate Graticule and configure the spectrum binning and sky evaluation zones. The dialogue is self explanatory and takes little practice to master. Figure 8: Setting binning and sky evaluation zones Tip: If necessary, the spectrum can be manually centred within the binning zone by un- checking the Auto vertical coordinate function box and then double clicking on the centre of the spectrum. 11

12 5. Display the neon calibration image and using the mouse, drag a vertical box around a single line to encapsulate an area for slant calculation. Press Slant to automatically populate the Slant angle field with the calculated value. Figure 9: Adjusting for slant and then setting x coordinate of reference wavelength Finally, set the X coordinate of line at wavelength entry. This is important to ensure that your dispersion coefficient is applied correctly to target calibration. It is accomplished by double clicking the cursor on a known line where it intersects the horizontal graticule and entering the associated wavelength in the adjacent box. ISIS will compute this coordinate to a precise value during execution. 6 Creating the profile Select the Go page in ISIS. Press the Go button. The sequence of processing steps will appear on the output display. When complete, press the Display profile button to reveal the calibrated spectral profile of your target. At this stage, the profile has not yet been corrected for instrument response. In order for IR correction to be included, an instrument response file needs to be generated, and then specified on the General page prior to processing the target spectra. This is covered in the next section. 12

13 Figure 10: Processing the spectra The profile can be saved before exiting ISIS. Figure 11: The calibrated profile (non IR corrected) 13

14 7 Instrument response correction ISIS beginner s guide. Version 2.0, September 2014 Reference star images to be used for instrument response correction are nominally acquired during the same imaging run as the target spectra, and reside in the same directory. 7.1 Create a calibrated profile of the reference star Step one in correcting for instrument response (IR) requires the creation of a calibrated profile of a chosen reference star and follows the same procedure previously outlined for processing target spectra. Because the reference star has been acquired at the same wavelength range and resolution, spectral dispersion does not need to be recalculated. The General page shown in Figure 12 has been updated to reflect the file name of the reference star and associated calibration frame acquired on the same night as the target spectra. Reference star images reside in the same directory as target images and use a similar naming convention. All other settings including those on the Settings tab remain unaltered. To keep things simple, this example also assumes that the files have already been bias and dark corrected. Accordingly, the yellow offset, dark and flat dialogues appear empty in Figure 12. Figure 12: General settings for the reference star (gamma Centauri) Follow the steps in section 5 and 6 to create a calibrated profile of the reference star. Instrument response curve generation begins with the profile active in the Profile display, as shown in Figure

15 Figure 13: The calibrated profile of the reference star 7.2 Load a standard reference spectra. Step two of IR creation is to load a standard reference spectra. Note: It is beyond the scope of this basic guide to provide a explanation of reference spectra and catalogues for IR correction. Some knowledge of spectral standards and reference catalogues is assumed. Selecting the Response button on the Profile page initiates the ISIS reference spectrum selection dialogue. The example in Figure 14 shows an A0III star selected from the Miles catalogue. 15

16 Figure 14: The ISIS reference spectrum dialogue Click Select. This will return you to the instrument response dialogue, and the profile display will update, showing the target (blue), reference (red) and ratio (green). Figure 15: Target, reference and ratio profiles Pressing OK will exit the dialogue presenting just the ratio, or instrument response in blue. 16

17 Figure 16: Instrument response ratio Important: Use the Crop tool to remove any rapid drop of intensity to zero that may exist at extreme ends of the spectra. 7.3 Creating a smoothed instrument response curve The final step involves some subjectivity in producing a prototype instrument response curve, and this guide is by no means an expert example. The following summarises the basic sequence of steps: 1. Select the Continuum button. 2. Select out the major absorption features by double clicking on either side of these features (Figure 17). 3. Experiment with the continuum dialogue controls to create a smooth curve that matches the instrument response profile (Figure 18). Some practice may be required. More detailed information on IR computation can be found at Christian Buil s web site: 17

18 Figure 17: Selecting out the major absorption features Figure 18: Using the controls on the continuum adjustment tool to create a smoothed IR curve 18

19 4. Save the profile with a name that allows it to be easily identified as an IR profile. Figure 19: Save the IR profile 7.4 Applying Instrument Response Correcting for IR once a response profile has been created and saved involves nothing more than referencing the IR profile on the General page before processing the target (Figure 20). 19

20 Figure 20: Specifying the IR profile to be used as instrument response for a target. Compare the profile in Figure 21 to the uncorrected profile on page 13. Figure 21: IR corrected profile Congratulations! You have just produced a calibrated and IR corrected profile using ISIS. 20

21 Appendix A Converting MaxIM DL sequence numbering to ISIS ISIS includes numerous and powerful tools for analysing and investigating image files. One of the simpler of these is a file sequencing tool that can be used to convert the file numbering used by MaxIM DL, to that required by ISIS. Figure 20 shows the intuitive interface, accessed from the Misc page. Enter the original name (omitting the extension) and check the image number box to verify that the files are found. Then enter an output name appended with a hyphen. Press Go to activate the conversion. The original files are preserved. Figure 22: MaxIM DL to ISIS file numbering conversion 21

22 Appendix B Averaging calibration frames ISIS beginner s guide. Version 2.0, September 2014 The Masters page includes a generic mean image computation tool that can be used to create an average of several calibration frames. Figure 23 shows the tool being used to create a mean neon image from 3 images obtained before, during and after the target sequence. In order for the tool to work, the individual files must be named using the ISIS numbering convention: neonetacarinae_heii- 1.fit neonetacarinae_heii- 2.fit neonetacarinae_heii- 3.fit As with all functions in ISIS, the final image is automatically saved to the default folder. Figure 23: Computing the mean from several images If you intend to use this new mean image to calibrate your target spectra, ensure that you select it as the calibration image on the General page. 22

23 Appendix C Advanced features ISIS beginner s guide. Version 2.0, September 2014 ISIS is an extremely powerful spectral processing package. A few examples include: Bias, dark and flat field correction ISIS includes sophisticated bias (offset), dark and flat field correction algorithms that include detailed auditing in the fits header and log files. A logical progression from basic use of ISIS is to incorporate image reduction within the ISIS pipeline. This is particularly important in the application of spectroscopic flat fields. XML data All settings and processing steps used in a project are automatically saved in an XML file stored in the default project directory. These files can be reloaded using the file access button adjacent to Root name on the General page. Appendix D provides information on how this feature can be used to process spectra of the same target and wavelength range on subsequent nights, without the need to recompute spectral dispersion coefficients and perform many other initial settings. Optimal binning and Wavelength registration The General page includes two checkboxes optimal binning and wavelength registration that can be used to improve the weighted vertical summing of spectra and the resolution respectively. Wavelength registration aligns all images in a sequence to the first image. As such it can be wise to ensure that the calibration frame used is one taken adjacent to the first target image in an otherwise long sequence. Interpolator type and Addition mode Experiment with these two options, available on the Settings page, to see if the appearance of a noisy profile can be improved. Refer to information on Christian Buil s web site for a thorough explanation of these and other advanced features in a variety of excellent documents: 23

24 ISIS repeat target processing - quick reference guide 1. General - Load the XML file from a project that shares the same spectral dispersion. responsegamcent 2. Settings - Navigate to the Working directory of the new project. 24

25 3. General navigate to and select the Root name of the new image sequence and press Auto check and if necessary change Object name check the result for Generic name and Number check and if necessary modify Calibration file select the instrument response file (after copying to root directory) check status of other General parameters, including Wavelength registration etacar 1 2 eta Carinae etacar neonetacar-1 responsegamcent 25

26 4. Calibration check image to process and calibration image file names. cycle through images (quick check) check vertical position and graticule settings perform Tilt adjustment on target image perform Slant adjustment on calibration image check and adjust X coordinate of line at wavelength 5. Go Press Go Select Display Profile Crop and Save 26

Guide to Processing Spectra Using the BASS Software

Guide to Processing Spectra Using the BASS Software British Astronomical Association Supporting amateur astronomers since 1890 Guide to Processing Spectra Using the BASS Software Andrew Wilson 04 June 2017 Applicable to BASS Project Version 1.9.7 by John

More information

Demetra User documentation DC0029A

Demetra User documentation DC0029A Demetra User documentation DC0029A Rev Date Who What 1.0 25/09/2017 F. Cochard First version (corrections from T. Rodda) Table of content 1 2 3 4 5 Introduction...2 Requirements...3 Installation...3 General

More information

Image Processing Tutorial Basic Concepts

Image Processing Tutorial Basic Concepts Image Processing Tutorial Basic Concepts CCDWare Publishing http://www.ccdware.com 2005 CCDWare Publishing Table of Contents Introduction... 3 Starting CCDStack... 4 Creating Calibration Frames... 5 Create

More information

Instruction Manual for HyperScan Spectrometer

Instruction Manual for HyperScan Spectrometer August 2006 Version 1.1 Table of Contents Section Page 1 Hardware... 1 2 Mounting Procedure... 2 3 CCD Alignment... 6 4 Software... 7 5 Wiring Diagram... 19 1 HARDWARE While it is not necessary to have

More information

SARG: The Graphical User Interface Manual

SARG: The Graphical User Interface Manual 1/28 SARG: The Graphical User Interface Manual Document: TNG-SARG-001 Issue: 1.0 Prepared by : Name: S. Scuderi Institute: INAF-Osservatorio Astrofisico di Catania Date : Approved by : Name: R. Cosentino

More information

NIRSPEC Data Reduction Pipeline Data Products Specification

NIRSPEC Data Reduction Pipeline Data Products Specification NIRSPEC Data Reduction Pipeline Data Products Specification Table of Contents 1 Introduction... 2 2 Data Products... 2 2.1 Tables...2 2.1.1 Table Format...2 2.1.2 Flux Table...3 2.1.3 Profile Table...4

More information

Information for users of the SOAR Goodman Spectrograph Multi-Object Slit (MOS) mode. César Briceño and Sean Points

Information for users of the SOAR Goodman Spectrograph Multi-Object Slit (MOS) mode. César Briceño and Sean Points Information for users of the SOAR Goodman Spectrograph Multi-Object Slit (MOS) mode César Briceño and Sean Points CTIO, June 2014 The Goodman Spectrograph has been offered for use in MOS mode starting

More information

Importing and processing gel images

Importing and processing gel images BioNumerics Tutorial: Importing and processing gel images 1 Aim Comprehensive tools for the processing of electrophoresis fingerprints, both from slab gels and capillary sequencers are incorporated into

More information

DBSP Observing Manual

DBSP Observing Manual DBSP Observing Manual I. Arcavi, P. Bilgi, N.Blagorodnova, K.Burdge, A.Y.Q.Ho June 18, 2018 Contents 1 Observing Guides 2 2 Before arrival 2 2.1 Submit observing setup..................................

More information

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer ThermaViz The Innovative Two-Wavelength Imaging Pyrometer Operating Manual The integration of advanced optical diagnostics and intelligent materials processing for temperature measurement and process control.

More information

PixInsight Workflow. Revision 1.2 March 2017

PixInsight Workflow. Revision 1.2 March 2017 Revision 1.2 March 2017 Contents 1... 1 1.1 Calibration Workflow... 2 1.2 Create Master Calibration Frames... 3 1.2.1 Create Master Dark & Bias... 3 1.2.2 Create Master Flat... 5 1.3 Calibration... 8

More information

CHROMACAL User Guide (v 1.1) User Guide

CHROMACAL User Guide (v 1.1) User Guide CHROMACAL User Guide (v 1.1) User Guide User Guide Notice Hello and welcome to the User Guide for the Datacolor CHROMACAL Color Calibration System for Optical Microscopy, a cross-platform solution that

More information

SBIG ASTRONOMICAL INSTRUMENTS

SBIG ASTRONOMICAL INSTRUMENTS SBIG ASTRONOMICAL INSTRUMENTS SANTA BARBARA INSTRUMENT GROUP 147-A Castilian Drive Santa Barbara, CA 93117 Phone (805) 571-SBIG (571-7244) FAX (805) 571-1147 e-mail:sbig@sbig.com home page:www.sbig.com

More information

VATTSpec Instructions Rev. 10/23/2015

VATTSpec Instructions Rev. 10/23/2015 VATTSpec Instructions Rev. 10/23/2015 Introduction VATTSpec is a medium resolution CCD range spectrograph with a skinny chip having excellent cosmetics. Its UA ITL chip, Serial Number 8228, has a gain

More information

Brightness and Contrast Control Reference Guide

Brightness and Contrast Control Reference Guide innovation Series Scanners Brightness and Contrast Control Reference Guide A-61506 Part No. 9E3722 CAT No. 137 0337 Using the Brightness and Contrast Control This Reference Guide provides information and

More information

ToupSky Cameras Quick-guide

ToupSky Cameras Quick-guide ToupSky Cameras Quick-guide ToupSky is a capture and processing software offered by Touptek, the original manufacturer of the Toupcamera series. These are video cameras that offer live image capture for

More information

Module 2: Radial-Line Sheet-Metal 3D Modeling and 2D Pattern Development: Right Cone (Regular, Frustum, and Truncated)

Module 2: Radial-Line Sheet-Metal 3D Modeling and 2D Pattern Development: Right Cone (Regular, Frustum, and Truncated) Inventor (5) Module 2: 2-1 Module 2: Radial-Line Sheet-Metal 3D Modeling and 2D Pattern Development: Right Cone (Regular, Frustum, and Truncated) In this tutorial, we will learn how to build a 3D model

More information

AgilEye Manual Version 2.0 February 28, 2007

AgilEye Manual Version 2.0 February 28, 2007 AgilEye Manual Version 2.0 February 28, 2007 1717 Louisiana NE Suite 202 Albuquerque, NM 87110 (505) 268-4742 support@agiloptics.com 2 (505) 268-4742 v. 2.0 February 07, 2007 3 Introduction AgilEye Wavefront

More information

ScanArray Overview. Principle of Operation. Instrument Components

ScanArray Overview. Principle of Operation. Instrument Components ScanArray Overview The GSI Lumonics ScanArrayÒ Microarray Analysis System is a scanning laser confocal fluorescence microscope that is used to determine the fluorescence intensity of a two-dimensional

More information

Geometric Functions. The color channel toolbar buttons are disabled.

Geometric Functions. The color channel toolbar buttons are disabled. Introduction to Geometric Transformations Geometric Functions The geometric transformation commands are used to shift, rotate, scale, and align images. For quick rotation by 90 or mirroring of an image,

More information

Guidance on Using Scanning Software: Part 5. Epson Scan

Guidance on Using Scanning Software: Part 5. Epson Scan Guidance on Using Scanning Software: Part 5. Epson Scan Version of 4/29/2012 Epson Scan comes with Epson scanners and has simple manual adjustments, but requires vigilance to control the default settings

More information

Leica TCS SP8 Quick Start Guide

Leica TCS SP8 Quick Start Guide Leica TCS SP8 Quick Start Guide Leica TCS SP8 System Overview Start-Up Procedure 1. Turn on the CTR Control Box, Fluorescent Light for the microscope stand. 2. Turn on the Scanner Power (1) on the front

More information

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Wyko RST Plus. All users are expected to have read and understood this document.

More information

32 Float v3 Quick Start Guide. AUTHORED BY ANTHONY HERNANDEZ (415)

32 Float v3 Quick Start Guide. AUTHORED BY ANTHONY HERNANDEZ (415) 32 Float v3 Quick Start Guide 32 Float v3 Trademark/Copyright Information Copyright 2013 by United Color Technologies, LLC. All rights reserved. Unified Color Technologies, BeyondRGB, and HDR Expose are

More information

Operating Rausch ScanCam within POSM.

Operating Rausch ScanCam within POSM. Operating Rausch ScanCam within POSM. POSM (Pipeline Observation System Management) // posmsoftware.com // info@posmsoftware.com // 859-274-0041 RAUSCH USA // www.rauschusa.com // reusa@rauschusa.com //

More information

APO TripleSpecTool User's Guide

APO TripleSpecTool User's Guide APO TripleSpecTool User's Guide Updated 09MAR2009 Table of Contents 7. APOTripleSpecTool 7.1. Installation 7.1.a. Computer Requirements 7.1.b. Download 7.1.c. IDL Setup 7.2. Data Preparation 7.3. Quickstart

More information

Working With Drawing Views-I

Working With Drawing Views-I Chapter 12 Working With Drawing Views-I Learning Objectives After completing this chapter you will be able to: Generate standard three views. Generate Named Views. Generate Relative Views. Generate Predefined

More information

Adobe Photoshop. Levels

Adobe Photoshop. Levels How to correct color Once you ve opened an image in Photoshop, you may want to adjust color quality or light levels, convert it to black and white, or correct color or lens distortions. This can improve

More information

ImagesPlus Basic Interface Operation

ImagesPlus Basic Interface Operation ImagesPlus Basic Interface Operation The basic interface operation menu options are located on the File, View, Open Images, Open Operators, and Help main menus. File Menu New The New command creates a

More information

MY ASTROPHOTOGRAPHY WORKFLOW Scott J. Davis June 21, 2012

MY ASTROPHOTOGRAPHY WORKFLOW Scott J. Davis June 21, 2012 Table of Contents Image Acquisition Types 2 Image Acquisition Exposure 3 Image Acquisition Some Extra Notes 4 Stacking Setup 5 Stacking 7 Preparing for Post Processing 8 Preparing your Photoshop File 9

More information

Picture Style Editor Ver Instruction Manual

Picture Style Editor Ver Instruction Manual ENGLISH Picture Style File Creating Software Picture Style Editor Ver. 1.15 Instruction Manual Content of this Instruction Manual PSE stands for Picture Style Editor. indicates the selection procedure

More information

Basic Hyperspectral Analysis Tutorial

Basic Hyperspectral Analysis Tutorial Basic Hyperspectral Analysis Tutorial This tutorial introduces you to visualization and interactive analysis tools for working with hyperspectral data. In this tutorial, you will: Analyze spectral profiles

More information

T I P S F O R I M P R O V I N G I M A G E Q U A L I T Y O N O Z O F O O T A G E

T I P S F O R I M P R O V I N G I M A G E Q U A L I T Y O N O Z O F O O T A G E T I P S F O R I M P R O V I N G I M A G E Q U A L I T Y O N O Z O F O O T A G E Updated 20 th Jan. 2017 References Creator V1.4.0 2 Overview This document will concentrate on OZO Creator s Image Parameter

More information

Alibre Design Tutorial: Loft, Extrude, & Revolve Cut Loft-Tube-1

Alibre Design Tutorial: Loft, Extrude, & Revolve Cut Loft-Tube-1 Alibre Design Tutorial: Loft, Extrude, & Revolve Cut Loft-Tube-1 Part Tutorial Exercise 5: Loft-Tube-1 [Complete] In this Exercise, We will set System Parameters first, then part options. Then, in sketch

More information

6. Very low level processing (radiometric calibration)

6. Very low level processing (radiometric calibration) Master ISTI / PARI / IV Introduction to Astronomical Image Processing 6. Very low level processing (radiometric calibration) André Jalobeanu LSIIT / MIV / PASEO group Jan. 2006 lsiit-miv.u-strasbg.fr/paseo

More information

Scanning Setup Guide for TWAIN Datasource

Scanning Setup Guide for TWAIN Datasource Scanning Setup Guide for TWAIN Datasource Starting the Scan Validation Tool... 2 The Scan Validation Tool dialog box... 3 Using the TWAIN Datasource... 4 How do I begin?... 5 Selecting Image settings...

More information

Stitching MetroPro Application

Stitching MetroPro Application OMP-0375F Stitching MetroPro Application Stitch.app This booklet is a quick reference; it assumes that you are familiar with MetroPro and the instrument. Information on MetroPro is provided in Getting

More information

Quintic Software Tutorial 7c

Quintic Software Tutorial 7c Quintic Software Tutorial 7c High-Speed Video Capture (Video Capture via USB or GigE) Contents Page 1. Single High-Speed Capture a. Camera Set-Up / Parameters b. Camera Tab (frame rate & exposure) c. Image

More information

Picture Style Editor Ver Instruction Manual

Picture Style Editor Ver Instruction Manual ENGLISH Picture Style File Creating Software Picture Style Editor Ver. 1.18 Instruction Manual Content of this Instruction Manual PSE stands for Picture Style Editor. In this manual, the windows used in

More information

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000 The ideal K-12 science microscope solution User Guide for use with the Nova5000 NovaScope User Guide Information in this document is subject to change without notice. 2009 Fourier Systems Ltd. All rights

More information

Leica TCS SP8 Quick Start Guide

Leica TCS SP8 Quick Start Guide Leica TCS SP8 Quick Start Guide Leica TCS SP8 System Overview Start-Up Procedure 1. Turn on the CTR Control Box, EL6000 fluorescent light source for the microscope stand. 2. Turn on the Scanner Power

More information

i800 Series Scanners Image Processing Guide User s Guide A-61510

i800 Series Scanners Image Processing Guide User s Guide A-61510 i800 Series Scanners Image Processing Guide User s Guide A-61510 ISIS is a registered trademark of Pixel Translations, a division of Input Software, Inc. Windows and Windows NT are either registered trademarks

More information

Goodman Cookbook. Goodman Spectrograph. Adapted by D. Sanmartim from L. Fraga's Guide. Sep SOAR Telescope

Goodman Cookbook. Goodman Spectrograph. Adapted by D. Sanmartim from L. Fraga's Guide. Sep SOAR Telescope Goodman Spectrograph 1 Goodman Spectrograph Documentation Goodman HTS Manual http://www.ctio.noao.edu/soar/content/goodman-hts-manual Goodman Overview http://www.ctio.noao.edu/soar/content/goodman-spectrograph-overview

More information

APO TripleSpecTool User s Guide

APO TripleSpecTool User s Guide APO TripleSpecTool User s Guide University of Virginia Astronomy Department July 16, 2009 Contents 1 Introduction 2 2 Installation 2 2.1 Computer Requirements....................................... 2 2.2

More information

AstroImageJ User Guide

AstroImageJ User Guide AstroImageJ User Guide Introduction AstroImageJ (AIJ) is simply ImageJ (IJ) with some customizations to the base code and a packaged set of astronomy specific plugins. The plugins are based on the Astronomy

More information

User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras

User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras The TWAIN & DirectX driver for PROGRES GRYPHAX USB 3.0 cameras enables user to operate with TWAIN and DirectX supported 3 rd party software

More information

inphoto ID PS Automatic ID photography With Canon PowerShot camera User Guide

inphoto ID PS Automatic ID photography With Canon PowerShot camera User Guide inphoto ID PS Automatic ID photography With Canon PowerShot camera User Guide 2018 Akond company Phone/fax: +7(812)384-6430 Cell: +7(921)757-8319 e-mail: info@akond.net akondsales@gmail.com http://www.akond.net

More information

Introduction to QTO. Objectives of QTO. Getting Started. Requirements. Creating a Bill of Quantities. Updating an existing Bill of Quantities

Introduction to QTO. Objectives of QTO. Getting Started. Requirements. Creating a Bill of Quantities. Updating an existing Bill of Quantities QTO User Manual Contents Introduction to QTO... 5 Objectives of QTO... 5 Getting Started... 5 QTO Manager... 6 QTO Layout... 7 Bill of Quantities... 8 Measure Folders... 9 Drawings... 10 Zooming and Scrolling...

More information

Picture Style Editor Ver Instruction Manual

Picture Style Editor Ver Instruction Manual ENGLISH Picture Style File Creating Software Picture Style Editor Ver. 1.12 Instruction Manual Content of this Instruction Manual PSE is used for Picture Style Editor. In this manual, the windows used

More information

User Manual for HoloStudio M4 2.5 with HoloMonitor M4. Phase Holographic Imaging

User Manual for HoloStudio M4 2.5 with HoloMonitor M4. Phase Holographic Imaging User Manual for HoloStudio M4 2.5 with HoloMonitor M4 Phase Holographic Imaging 1 2 HoloStudio M4 2.5 Software instruction manual 2013 Phase Holographic Imaging AB 3 Contact us: Phase Holographic Imaging

More information

Manual Stitching of Multiple Images to Produce a Panorama

Manual Stitching of Multiple Images to Produce a Panorama Manual Stitching of Multiple Images to Produce a Panorama Covered in this PS CC tutorial: The purpose of this tutorial goes beyond manual stitching. The techniques used can be used to incorporate a cut

More information

i1800 Series Scanners

i1800 Series Scanners i1800 Series Scanners Scanning Setup Guide A-61580 Contents 1 Introduction................................................ 1-1 About this manual........................................... 1-1 Image outputs...............................................

More information

Cerro Tololo Inter-American Observatory. CHIRON manual. A. Tokovinin Version 2. May 25, 2011 (manual.pdf)

Cerro Tololo Inter-American Observatory. CHIRON manual. A. Tokovinin Version 2. May 25, 2011 (manual.pdf) Cerro Tololo Inter-American Observatory CHIRON manual A. Tokovinin Version 2. May 25, 2011 (manual.pdf) 1 1 Overview Calibration lamps Quartz, Th Ar Fiber Prism Starlight GAM mirror Fiber Viewer FEM Guider

More information

Introduction to Autodesk Inventor for F1 in Schools (Australian Version)

Introduction to Autodesk Inventor for F1 in Schools (Australian Version) Introduction to Autodesk Inventor for F1 in Schools (Australian Version) F1 in Schools race car In this course you will be introduced to Autodesk Inventor, which is the centerpiece of Autodesk s Digital

More information

Visioneer OneTouch Scanner. Installation Guide FOR WINDOWS

Visioneer OneTouch Scanner. Installation Guide FOR WINDOWS Visioneer OneTouch Scanner Installation Guide FOR WINDOWS TABLE OF CONTENTS i TABLE OF CONTENTS Getting Started with your new Scanner....................... 1 Step 1: Installing the Scanner Software.......................

More information

Leica DMi8A Quick Guide

Leica DMi8A Quick Guide Leica DMi8A Quick Guide 1 Optical Microscope Quick Start Guide The following instructions are provided as a Quick Start Guide for powering up, running measurements, and shutting down Leica s DMi8A Inverted

More information

We recommend downloading the latest core installer for our software from our website. This can be found at:

We recommend downloading the latest core installer for our software from our website. This can be found at: Dusk Getting Started Installing the Software We recommend downloading the latest core installer for our software from our website. This can be found at: https://www.atik-cameras.com/downloads/ Locate and

More information

Photoshop CC Editing Images

Photoshop CC Editing Images Photoshop CC Editing Images Rotate a Canvas A canvas can be rotated 90 degrees Clockwise, 90 degrees Counter Clockwise, or rotated 180 degrees. Navigate to the Image Menu, select Image Rotation and then

More information

Microscopy from Carl Zeiss

Microscopy from Carl Zeiss Microscopy from Carl Zeiss Contents Page Contents... 1 Introduction... 1 Starting the System... 2 Introduction to ZEN Efficient Navigation... 5 Setting up the microscope... 10 Configuring the beam path

More information

A Stony Brook Student s Guide to Using CCDSoft By Stephanie Zajac Last Updated: 3 February 2012

A Stony Brook Student s Guide to Using CCDSoft By Stephanie Zajac Last Updated: 3 February 2012 A Stony Brook Student s Guide to Using CCDSoft By Stephanie Zajac Last Updated: 3 February 2012 This document is meant to serve as a quick start guide to using CCDSoft to take data using the Mt. Stony

More information

Blab Gallery Uploads: How to Reduce and/or Rotate Your Photo Last edited 11/20/2016

Blab Gallery Uploads: How to Reduce and/or Rotate Your Photo Last edited 11/20/2016 Blab Gallery Uploads: How to Reduce and/or Rotate Your Photo Contents & Links QUICK LINK-JUMPS to information in this PDF document Photo Editors General Information Includes finding pre-installed editors

More information

ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide

ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide Copyright Notice 1999 Canon Inc. This manual is copyrighted with all rights reserved. Under the copyright laws, this manual

More information

5. SilverFast Tools Tools SilverFast Manual. 5. SilverFast Tools Image Auto-Adjust (Auto-Gradation) 114

5. SilverFast Tools Tools SilverFast Manual. 5. SilverFast Tools Image Auto-Adjust (Auto-Gradation) 114 Chapter 5 Tools 5. SilverFast Tools 5. SilverFast Tools 106 5.1 Image Auto-Adjust (Auto-Gradation) 114 5.2 Highlight / Shadow Tool 123 5.3 The Histogram 133 5.4 Gradation Dialogue 147 5.5 Global Colour

More information

The user should already be familiar with operation of the instrument in STEM mode, use of the Microscope Control interface, and TIA.

The user should already be familiar with operation of the instrument in STEM mode, use of the Microscope Control interface, and TIA. FEI Tecnai F20 S/TEM: EDS system operation Nicholas G. Rudawski ngr@ufl.edu (805) 252-4916 (352) 392-3077 Last updated: 01/22/18 The user should already be familiar with operation of the instrument in

More information

Exercise 4-1 Image Exploration

Exercise 4-1 Image Exploration Exercise 4-1 Image Exploration With this exercise, we begin an extensive exploration of remotely sensed imagery and image processing techniques. Because remotely sensed imagery is a common source of data

More information

Applying mathematics to digital image processing using a spreadsheet

Applying mathematics to digital image processing using a spreadsheet Jeff Waldock Applying mathematics to digital image processing using a spreadsheet Jeff Waldock Department of Engineering and Mathematics Sheffield Hallam University j.waldock@shu.ac.uk Introduction When

More information

WFC3 TV3 Testing: IR Channel Nonlinearity Correction

WFC3 TV3 Testing: IR Channel Nonlinearity Correction Instrument Science Report WFC3 2008-39 WFC3 TV3 Testing: IR Channel Nonlinearity Correction B. Hilbert 2 June 2009 ABSTRACT Using data taken during WFC3's Thermal Vacuum 3 (TV3) testing campaign, we have

More information

Enhancement of Multispectral Images and Vegetation Indices

Enhancement of Multispectral Images and Vegetation Indices Enhancement of Multispectral Images and Vegetation Indices ERDAS Imagine 2016 Description: We will use ERDAS Imagine with multispectral images to learn how an image can be enhanced for better interpretation.

More information

Infinity Software Manual

Infinity Software Manual Infinity Software Manual Version 1.5 - October 2017 1 Contents Introduction 4 Getting Started 5 Main Screen 6 Mode Selection 7 Replay Mode 7 Taking an Image 8 Play 8 Exposure Progress 8 Exposure Settings

More information

v Introduction Images Import images in a variety of formats and register the images to a coordinate projection WMS Tutorials Time minutes

v Introduction Images Import images in a variety of formats and register the images to a coordinate projection WMS Tutorials Time minutes v. 10.1 WMS 10.1 Tutorial Import images in a variety of formats and register the images to a coordinate projection Objectives Import various types of image files from different sources. Learn how to work

More information

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide Operation 58. UltraVIEW VoX Getting Started Guide Overview This chapter outlines the basic methods used to operate the UltraVIEW VoX system. About other software Volocity places great demands on the computer

More information

FoamWorks Introduction. David Mrozinski 848 W. Borton Road Essexville, Michigan 48732

FoamWorks Introduction. David Mrozinski 848 W. Borton Road Essexville, Michigan 48732 FoamWorks 4.0 Introduction Quick Start Registration Registration Menus Files Save a Cut Profile Load a Cut Profile Close Profile/G-code Restore Default Cut Profile Exit Setup Setup Parameters Generate

More information

Topaz Labs DeNoise 3 Review By Dennis Goulet. The Problem

Topaz Labs DeNoise 3 Review By Dennis Goulet. The Problem Topaz Labs DeNoise 3 Review By Dennis Goulet The Problem As grain was the nemesis of clean images in film photography, electronic noise in digitally captured images can be a problem in making photographs

More information

NOISEWARE 5 USER'S GUIDE PLUG-IN BY IMAGENOMIC

NOISEWARE 5 USER'S GUIDE PLUG-IN BY IMAGENOMIC NOISEWARE 5 PLUG-IN USER'S GUIDE BY IMAGENOMIC 2012 Updated May 17, 2012 Contact Imagenomic at http://www.imagenomic.com/contact Copyright 2004-2012 Imagenomic, LLC. All rights reserved 2 TABLE OF CONTENTS

More information

User Guide V10 SP1 Addendum

User Guide V10 SP1 Addendum Alibre Design User Guide V10 SP1 Addendum Copyrights Information in this document is subject to change without notice. The software described in this document is furnished under a license agreement or

More information

JEOL 6500 User Manual

JEOL 6500 User Manual LOG IN to your session on the computer to the left of the microscope. Starting Conditions 1. Press Ctrl-Alt-Del and log on to the microscope computer. Click on JEOL PC SEM 6500 icon. Click yes if message

More information

A Guide to AstroImageJ Differential Photometry

A Guide to AstroImageJ Differential Photometry British Astronomical Association Supporting amateur astronomers since 1890 A Guide to AstroImageJ Differential Photometry Image Display Interface with WASP-12b Target and Comparison Aperture overlay Richard

More information

262 The Astrophotography Manual. Templates

262 The Astrophotography Manual. Templates 262 The Astrophotography Manual Templates I really didn t foresee the Internet. But then, neither did the computer industry. Not that that tells us very much of course the computer industry didn t even

More information

inphoto ID SLR Automatic ID photography With Canon SLR camera User Guide

inphoto ID SLR Automatic ID photography With Canon SLR camera User Guide inphoto ID SLR Automatic ID photography With Canon SLR camera User Guide 2014 Akond company Phone/fax: +7(812)384-6430 Cell: +7(921)757-8319 e-mail: info@akond.net akondsales@gmail.com http://www.akond.net

More information

FLDIGI Users Manual: WEFAX

FLDIGI Users Manual: WEFAX w1hkj.com 10-13 minutes This modem is able to receive and transmit HF-Fax images, traditionally used for weather reports. More technical information is available on the wikipedia article Radiofax. Two

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Procedure Nanosurf Atomic Force Microscopy Operation Facility NCCRD Nanotechnology Center for Collaborative Research and Development Department of Chemistry and Engineering Physics The

More information

7. RECTIFICATION (GEOMETRIC CORRECTION) OF IMAGES AND RESAMPLING

7. RECTIFICATION (GEOMETRIC CORRECTION) OF IMAGES AND RESAMPLING Rectification of images and resampling 7. RECTIFICATION (GEOMETRIC CORRECTION) OF IMAGES AND RESAMPLING Aim: To introduce you to methods of rectifying images and linking them to geographical coordinate

More information

Zoom Set Too Tight Zoom Set Correctly Zoom Set Too Wide

Zoom Set Too Tight Zoom Set Correctly Zoom Set Too Wide The ISG-E300 AutoCam Elite offers special features that increase capture efficiency and enhance image quality. By following the procedures outlined in this document, the ISG-E300 Elite can be used to its

More information

This procedure assumes the user is already familiar with basic operation of the SEM and the MiraTC interface.

This procedure assumes the user is already familiar with basic operation of the SEM and the MiraTC interface. Tescan MIRA3 SEM: EDS using EDAX TEAM Nicholas G. Rudawski ngr@ufl.edu Cell: (805) 252-4916 Office: (352) 392-3077 Last updated: 12/04/17 This procedure assumes the user is already familiar with basic

More information

LA-T LED ANALYSER EVALUATION KIT INSTRUCTION MANUAL. rev

LA-T LED ANALYSER EVALUATION KIT INSTRUCTION MANUAL. rev LA-T LED ANALYSER EVALUATION KIT INSTRUCTION MANUAL rev. 300117 TABLE OF CONTENTS General Information 3 Application 3 Design 3 Features 3 Operation conditions 3 Operation instructions 4-7 2 GENERAL INFORMATION

More information

Renishaw InVia Raman microscope

Renishaw InVia Raman microscope Laser Spectroscopy Labs Renishaw InVia Raman microscope Operation instructions 1. Turn On the power switch, system power switch is located towards the back of the system on the right hand side. Wait ~10

More information

Unit 2: Smiley Basics Student Guide. Derek Dennis

Unit 2: Smiley Basics Student Guide. Derek Dennis Unit 2: Smiley Basics Student Guide Derek Dennis KENAN FELLOWS PROJECT 2010 Smiley Basics Student Guide 2010 Edition Student: Teacher: Class Period: Unit 2: Smiley Basics Student Guide 1 Table of Contents

More information

MEASUREMENT CAMERA USER GUIDE

MEASUREMENT CAMERA USER GUIDE How to use your Aven camera s imaging and measurement tools Part 1 of this guide identifies software icons for on-screen functions, camera settings and measurement tools. Part 2 provides step-by-step operating

More information

OzE Field Modules. OzE School. Quick reference pages OzE Main Opening Screen OzE Process Data OzE Order Entry OzE Preview School Promotion Checklist

OzE Field Modules. OzE School. Quick reference pages OzE Main Opening Screen OzE Process Data OzE Order Entry OzE Preview School Promotion Checklist 1 OzE Field Modules OzE School Quick reference pages OzE Main Opening Screen OzE Process Data OzE Order Entry OzE Preview School Promotion Checklist OzESchool System Features Field unit for preparing all

More information

A guide to SalsaJ. This guide gives step-by-step instructions on how to use SalsaJ to carry out basic data analysis on astronomical data files.

A guide to SalsaJ. This guide gives step-by-step instructions on how to use SalsaJ to carry out basic data analysis on astronomical data files. A guide to SalsaJ SalsaJ is free, student-friendly software developed originally for the European Hands- On Universe (EU-HOU) project. It is designed to be easy to install and use. It allows students to

More information

truepixa Chromantis Operating Guide

truepixa Chromantis Operating Guide truepixa Chromantis Operating Guide CD40150 Version R04 Table of Contents 1 Intorduction 4 1.1 About Chromasens 4 1.2 Contact Information 4 1.3 Support 5 1.4 About Chromantis 5 1.5 Software Requirements

More information

32 Float v2 Quick Start Guide. AUTHORED BY ANTHONY HERNANDEZ - (415)

32 Float v2 Quick Start Guide. AUTHORED BY ANTHONY HERNANDEZ - (415) 32 Float v2 Quick Start Guide 32 Float V2 Trademark/Copyright Information Copyright 2011 by United Color Technologies, LLC. All rights reserved. Unified Color Technologies, BeyondRGB, and HDR Float are

More information

Benchtop System Quick Start

Benchtop System Quick Start Benchtop System Quick Start Release 5.2 Resonon Inc. Dec 11, 2018 CONTENTS 1 System Overview 1 2 Basic Data Acquisition 3 2.1 Data Modes................................................ 3 2.2 Start The

More information

For customers in USA This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

For customers in USA This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: User manual For customers in North and South America For customers in USA This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not

More information

F/48 Slit Spectroscopy

F/48 Slit Spectroscopy 1997 HST Calibration Workshop Space Telescope Science Institute, 1997 S. Casertano, et al., eds. F/48 Slit Spectroscopy R. Jedrzejewski & M. Voit Space Telescope Science Institute, Baltimore, MD 21218

More information

Southern African Large Telescope. RSS CCD Geometry

Southern African Large Telescope. RSS CCD Geometry Southern African Large Telescope RSS CCD Geometry Kenneth Nordsieck University of Wisconsin Document Number: SALT-30AM0011 v 1.0 9 May, 2012 Change History Rev Date Description 1.0 9 May, 2012 Original

More information

Quick Start for Autodesk Inventor

Quick Start for Autodesk Inventor Quick Start for Autodesk Inventor Autodesk Inventor Professional is a 3D mechanical design tool with powerful solid modeling capabilities and an intuitive interface. In this lesson, you use a typical workflow

More information

Editing your digital images:

Editing your digital images: Editing your digital images: 1 By Garry Sankowsky zodpub@rainforestmagic.com.au All images taken with a digital camera need to be edited. You will usually get software with your camera that can do at least

More information

ScanMate. i920 Scanner. Scanning Setup Guide for TWAIN Applications A-61733

ScanMate. i920 Scanner. Scanning Setup Guide for TWAIN Applications A-61733 ScanMate i920 Scanner Scanning Setup Guide for TWAIN Applications A-61733 Scanning Setup Guide for the TWAIN Datasource Starting the Scan Validation Tool... 2 The Scan Validation Tool dialog box... 3 Using

More information

XTcalc: MOSFIRE Exposure Time Calculator v2.3

XTcalc: MOSFIRE Exposure Time Calculator v2.3 XTcalc: MOSFIRE Exposure Time Calculator v2.3 by Gwen C. Rudie gwen@astro.caltech.edu July 2, 2012 1 Installation using IDL Virtual Machine This is the default way to run the code. It does not require

More information