CruzPro VAH-65. Advanced 3 BankVolts, 1 Bank Amps/Amp-Hour Monitor/w Alarms & NMEA 0183

Size: px
Start display at page:

Download "CruzPro VAH-65. Advanced 3 BankVolts, 1 Bank Amps/Amp-Hour Monitor/w Alarms & NMEA 0183"

Transcription

1 Other CruzPro Products Depthsounders, Fishfinder & Speed/Temperature/Log DC Vots/Amps/Amp-Hour Monitors AC Vots/Amps/Freq/kW Monitor LPG/Petro Gas Detectors/Aarms Bige Water Aarms & Bige Pump Controers Windass Controer/Chain Counter Digita Fue Gauges & Fue Consumption Cacuator Digita Gauge for 1 or 3 Tanks /w Separate Aarms Smart 4 step Aternator Reguator Marine Security System/w Reiabe Intrusion Sensors RPM/Engine Hours/Eapsed Time Gauge/w Aarm Digita Oi Pressure Gauge/Aarm Digita Temperature Gauges for 1 or 3 Areas /w Aarms One and Three Bank Digita Vots Gauges Digita Amps Gauge Digita Cock/Watch/Race Timers/w 8 Aarms 8 and 16 Amp Light Dimmers / Motor Speed Controer Soar Pane Charge Controers 6/8/9 & 20 Amps 4 & 8 Channe NMEA Combiners/RS-232 Convertors Engine/Exhaust Temp. Monitor & Digita Pyrometer NMEA 0183 Remote Data Repeater/w 4 Input Channes CruzPro VAH-65 Advanced 3 BankVots, 1 Bank Amps/Amp-Hour Monitor/w Aarms & NMEA 0183 To set the ower charge contro output imit in percent (charger turn-on point), press both the : and s keys to dispay Amp-Hours Remaining in percent. Then hod down both the t key for 10 seconds (unti you hear a ong beep). The ower charge contro imit wi be dispayed in percent. Use the t and s keys to set the desired vaue. Press the : key to save the new vaue to memory. Resetting Amp-Hours Remaining Whie viewing Amp-Hours Remaining, press and hod the s key for 10 seconds (unti you hear a ong beep). The Amp-Hours Remaining wi be reset to the fu amphour capacity of the battery. Page 18 Introduction The VAH-65 Battery Monitor provides accurate instrumentation for 3 banks of batteries between 9.5 and 33.0 Vots. The VAH-65 dispays votage for three banks and amps or amp-hours for your house bank. It tracks a current entering and eaving the house bank and appies Peukert's and efficiency factors. You can set Low and High votage aarms and Low Amp-Hours Remaining aarms. When activated, the buit-in 85 db aarm wi sound and the dispay wi fash. The VAH- 65 outputs NMEA 0183 seria data or the data ine can be programmed as an externa aarm output or as a charger ON/OFF contro. Five eves of backighting can be seected and a set-up, caibration constants and aarm vaues are saved to nonvoatie memory. The VAH-65 comes compete with a precision shunt and is designed to work with 50 to 600 amp 50mV shunts. Page 3

2 Tabe of Contents Introduction Specifications Instaation Operation Key Functions Turning Aarms ON/OFF Backight Intensity Dispay Vots/Amps/A-H/ A-H % Remaining Setting High & Low Vots Aarms Setting Low Amp-Hours Aarm Changing Battery Capacity Changing Charge Efficiency Changing Peukert's Exponent Caibration/Zeroing/Adjusting Amp-Hour Drift NMEA 0183 Sentences Seect NMEA, Ext. Aarm or Charger Contro Output Setting Charger Contro ON/OFF Limits Resetting Amp-Hours Remaining Notes and Warnings CruzPro Ltd. V65MAN-N Made in New Zeaand Notes and Warnings a) When setting functions that require you to hod down a key whie appying power - turn OFF the power first, then hod the key(s) down during and for at east 3 seconds AFTER the power has been reappied. b) A dispay of " " means the unit thinks the amp reading is greater than -450 amps (450 amps is the imit for cacuating discharge current). c) It is important to run a dedicated ground wire from pin A a the way back to the shunt negative termina. Do not share this ground wire with any other equipment. Use a separate wire - do not share this connection with the shunt- signa wire. Page 19 Specifications Power suppy: 9.5 to 33.0 VDC,.018 amps nom. Operating temperature: 32 to 122 F ( 0 to 50 C) Size: 2.5" dia X 4.1" deep (61mm x 104 mm). Accuracy: Better than +/- 0.1 VDC for vots and 1% +/-1 Amp for amps, front pane adjustabe. Ranges: Vots 1,2 & to 33.0 VDC Amps to 450 Amps Amp-Hours to 3000 A/H Capacity Remaining - 0 to 100% Shunt: 450 Amp 50mV shunt. Aarms: High, Low Votage & Low Amp-Hours Dispay: 4 digit LCD, 5 eves of backighting. Output Signa: NMEA 0183, Externa Aarm or Automatic Charger Contro Page 4 Setting Charge Contro ON/OFF Limits If the Charger Contro function is seected for screw termina (B), the VAH65 can be programmed to turn a charger on/off automaticay when required, depending on Amp-Hours Remaining. The factory defaut vaue is to switch the charge source ON when Amp-Hours Remaining drops down to 50% of battery capacity and switch OFF when Amp-Hours Remaining is back up to 90% of battery capacity. Screw termina (B) wi output a +5V signa when the charger is to be activated. To set the upper charge contro output imit (charger turn OFF point) in percent, press both the : and s keys to dispay Amp-Hours Remaining in percent. Then hod down the s key for 10 seconds (unti you hear a ong beep). The upper charge contro imit wi be dispayed in percent. Use the t and s keys to set the desired vaue. Press the : key to save the new vaue to memory. Page 17

3 Seect NMEA, Ext. Aarm or Charger Contro Output Screw termina pin (B) can be programmed as a NMEA 0183 data output, Externa Aarm Output or as a Charger ON/OFF Contro ine. The factory defaut is NMEA 0183 seria data. To togge Screw Termina Pin (B) between NMEA 0183, Externa Aarm Output and Charger Contro, press and hod down both the t and s keys for 10 seconds (unti you hear a ong beep). The dispay wi togge between showing "data", "E-AL" or "-CC- " to show you which mode is seected. The new output mode is automaticay saved to memory. A 5V signa (10 ma Max.) is output on screw termina (B) whenever an aarm condition exists and the aarms are enabed or whenever a charger is to be turned ON automaticay. Page 16 Instaation Before starting the instaation, pease read this entire section first. Be sure to insta the bukhead gasket before you insta the instrument. Finger tighten the screws that mount the instrument bracket - do not use toos. Figure 1 Finger tighten ony - Do not use toos Bukhead Gasket 2-1/8" (55mm) hoe Mounting Bracket Page 5 discussed above, then press and hod the key whie appying power to the instrument. Use the t and s keys to make the dispayed vaue read correcty. Press the : key for 1/2 second to save the amps caibration data to memory. The VAH65 is not accurate enough to, track the amphours for weeks on end whie your boat is at the sip not being used. Sma caibration and measurement errors wi eventuay accumuate and cause the dispayed amp-hours to sowy drift away from the actua amphours remaining in the battery. To minimize the ongterm drift you can program a amp-hours drift compensation vaue between 0 and 100 into the VAH65. The nomina drift compensation vaue is 55. To change the amp-hour drift vaue press and hod both the t and : keys when appying power to the VAH65. Use the s Page 14 (Connect to SHUNT-) Figure 3 Carefuy check a your wiring against figures 2 and 3. You can then mount the VAH65 in the instrument hoe. Insure that the bukhead gasket is in pace and use ony finger tension to tighten the bracket hod-down nuts Do not overtighten the bracket or you may damage the case. Check the Notes and Warning on page 19 for wiring the ground connection. Page 7

4 Dri a 2-1/8" (55mm) mounting hoe where you desire to mount the instrument (Figure 1). Bring the shunt wires, ground, and power ines out of the mounting hoe and use a sma fat screwdriver to make the connections to the screw termina on the instrument case back as shown in Figure 2 and Figure 3. and t keys to set the desired vaue. Press the : key for 1/2 second to save the new vaue. If the dispayed amp-hours is drifting down faster than it shoud, increase the drift compensation vaue sighty. Decrease the drift compensation vaue sighty if the amp-hours is drifting up faster than it shoud. NMEA 0183 Sentences The VAH65 can output seria data of battery votage, amps and amp-hours remaining in NMEA 0183 format. The sentences are output on screw termina (B) in the foowing formats: Page 6 Figure 2 Vots: $IIXDR,U,xx.x,V,VAH35*CS Amps: $IIXDR,I,xxxx,A,VAH35*CS A-H Remaining: $IIXDR,G,xxxx,,VAH35*CS *CS = Check Sum Page 15 Key Functions Operation The keys are used to seect what to dispay, backights, caibrate vots/amps, turn aarms on/off, set aarms and set/change constants. New information is automaticay saved to memory when the : key is pressed. Turning Aarms ON/OFF Press the s key 1/2 second to turn aarms ON. In Votage mode, the Battery1 icon wi bink. Press the t key 1/2 second to turn the aarms OFF. Backight Intensity Press : the key 1/2 second to adjust the backight eve for night viewing. Each time you press the : key 1/2 second, the eve wi get brighter 1, 2, 3, 4, OFF, Caibration/Zeroing/Adjusting Amp-Hour Drift The VAH-65 is caibrated at time of manufacture, but can be caibrated using the front pane keys. To caibrate the votmeter, press and hod the key whie appying power to the instrument. Use the t and s keys to make the dispayed vaue read correcty. Press the: key for 1/2 second to save the caibration data to memory. To make the ammeter read zero when no current is being used, press and hod the : key for 10 seconds whie viewing Amps. The VAH65 wi dispay "AUTO", automaticay zero the reading and save the auto-zero information into memory. To caibrate the Ammeter, first zero the amps scae as Page 8 Page 13

5 Changing Peukert's Exponent Peukert's Exponent reates how efficienty you can draw current from a battery. Because of inefficiencies, the faster you drain the battery, the smaer the battery appears to be. The defaut Peukert's Exponent is 1.25 (shown as 125), which is typica for many batteries. To change Peukert's Exponent, press and hod the : and s keys whie appying power to the instrument. Peukert's exponent wi be dispayed. Use the t and s keys to set the desired vaue. Press the : key for 1/2 second to save the new vaue. If your battery seems to discharge faster than what the VAH-65 is teing you, try increasing Peukert's Exponent sighty. Lower the exponent if the reverse is true. The correct setting wi depend upon how your battery was manufactured and it's age, etc. Page 12 1, 2,... etc. Screw termina pin (D) must be switched ON for the backights to work. Dispay Vots/Amps/A-H/ A-H % Remaining Quick press the, or keys to seect Battery Votage, Amps or Amp-Hours dispay. Pressing the key repeatedy wi step the dispay through Battery 1, 2, 3, 1, etc. To dispay the Capacity Remaining (Amp-Hours% Remaining), press the and keys simutaneousy. Setting High Vots Aarm Whie viewing Battery #1 vots, press and hod the s key for ten (10) seconds (unti you hear a ong beep). Page 9 Changing Peukert's Exponent Peukert's Exponent reates how efficienty you can draw current from a battery. Because of inefficiencies, the faster you drain the battery, the smaer the battery appears to be. The defaut Peukert's Exponent is 1.25 (shown as 125), which is typica for many batteries. To change Peukert's Exponent, press and hod the : and s keys whie appying power to the instrument. Peukert's exponent wi be dispayed. Use the t and s keys to set the desired vaue. Press the : key for 1/2 second to save the new vaue. If your battery seems to discharge faster than what the VAH-65 is teing you, try increasing Peukert's Exponent sighty. Lower the exponent if the reverse is true. The correct setting wi depend upon how your battery was manufactured and it's age, etc. Page 12 1, 2,... etc. Screw termina pin (D) must be switched ON for the backights to work. Dispay Vots/Amps/A-H/ A-H % Remaining Quick press the, or keys to seect Battery Votage, Amps or Amp-Hours dispay. Pressing the key repeatedy wi step the dispay through Battery 1, 2, 3, 1, etc. To dispay the Capacity Remaining (Amp-Hours% Remaining), press the and keys simutaneousy. Setting High Vots Aarm Whie viewing Battery #1 vots, press and hod the s key for ten (10) seconds (unti you hear a ong beep). Page 9

6 The High Vots aarm vaue wi be dispayed. Use the t and s keys to set the desired aarm vaue. Press the : key for 1/2 second to save the High Vots Aarm vaue to memory. Setting Low Vots Aarm Whie viewing Battery #1 vots, press the t key for ten (10) seconds. You wi hear a beep and the Low Vots aarm vaue wi be dispayed. Use the t and s keys to set the desired aarm vaue. Press the : key for 1/2 second to save the new aarm vaue. Setting Low Amp-Hours Aarm Whie viewing Amp-Hours, press and hod the t key for ten (10) seconds (unti you hear a ong beep). The Low Amp-Hours aarm vaue wi be dispayed. Use the t and s keys to change it. Press the : key Page 10 for 1/2 second to save the new vaue. Changing Battery Capacity Press and hod the s key whie appying power to the VAH65. The Battery Capacity (in Amp-Hours) wi be dispayed. Use the t and s keys to change it. Press the : key for 1/2 second to save it. Changing Charge Efficiency The Defaut Charge Efficiency is 80% (meaning you get back 80% of what you put into the battery. To change it, press and hod both the t and s keys and appy power to the VAH65. Charge Efficiency % is dispayed. Use thet and s keys to change it. Press the : key for 1/2 second to save the new vaue. Page 11 The High Vots aarm vaue wi be dispayed. Use the t and s keys to set the desired aarm vaue. Press the : key for 1/2 second to save the High Vots Aarm vaue to memory. Setting Low Vots Aarm Whie viewing Battery #1 vots, press the t key for ten (10) seconds. You wi hear a beep and the Low Vots aarm vaue wi be dispayed. Use the t and s keys to set the desired aarm vaue. Press the : key for 1/2 second to save the new aarm vaue. Setting Low Amp-Hours Aarm Whie viewing Amp-Hours, press and hod the t key for ten (10) seconds (unti you hear a ong beep). The Low Amp-Hours aarm vaue wi be dispayed. Use the t and s keys to change it. Press the : key Page 10 for 1/2 second to save the new vaue. Changing Battery Capacity Press and hod the s key whie appying power to the VAH65. The Battery Capacity (in Amp-Hours) wi be dispayed. Use the t and s keys to change it. Press the : key for 1/2 second to save it. Changing Charge Efficiency The Defaut Charge Efficiency is 80% (meaning you get back 80% of what you put into the battery. To change it, press and hod both the t and s keys and appy power to the VAH65. Charge Efficiency % is dispayed. Use thet and s keys to change it. Press the : key for 1/2 second to save the new vaue. Page 11

CruzPro FU60. Intelligent Digital Fuel Gauge/w Alarms & Consumption Calculator

CruzPro FU60. Intelligent Digital Fuel Gauge/w Alarms & Consumption Calculator Other CruzPro Products Depthsounders & Speed/Temperature/Logs PC Based Fishfinders and Active Depth Transducers DC Vots/Amps/Amp-Hour Monitor AC Vots/Amps/Freq/kW Monitor LPG/Petro Gas Detectors/Aarms

More information

CruzPro. MaxRp110. 4/8 Channel NMEA 0183 Data Repeater

CruzPro. MaxRp110. 4/8 Channel NMEA 0183 Data Repeater CruzPro MaxRp110 4/8 Channe NMEA 0183 Data Repeater 2008 CruzPro Ltd. MaxRp110 Manua Ver. AF http://www.cruzpro.com Made in New Zeaand Page 2 Tabe of Contents Introduction............................ 5

More information

CruzPro CS60. Clock With Four Timed 12 VDC Switches

CruzPro CS60. Clock With Four Timed 12 VDC Switches Warranty Each CruzPro product is carefully tested and calibrated at the factory before shipping and is warranted for one full year against original defects in materials or workmanship. This warranty does

More information

CTC CT TRANSMITTER. (clamp-on current sensor) BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL CTC

CTC CT TRANSMITTER. (clamp-on current sensor) BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL CTC INSTRUCTION MANUA CT TRANSMITTER (camp-on current sensor) MODE CTC CTC BEFORE USE... Than you for choosing M-System. Before use, chec the contents of the pacage you received as outined beow. If you have

More information

Operation Guide

Operation Guide MO0907-EB Operation Guide 709 713 Getting Acquainted Congratuations upon your seection of this CASO watch. To get the most out of your purchase, be sure to read this manua carefuy. Expose the watch to

More information

RED LION CONTROLS MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER

RED LION CONTROLS MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER RED LION CONTROLS INTERNATIONAL HEADQUARTERS EUROPEAN HEADQUARTERS 20 Wiow Springs Circe, York, Pa. 17402, (717) 767-6511 FAX: (717) 764-0839 892 Pymouth Road, Sough, Berkshire SL1 4LP Web site- http://www.redion-contros.com

More information

Manual SURFACE ROUGHNESS TESTER PCE-RT 1200

Manual SURFACE ROUGHNESS TESTER PCE-RT 1200 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Te: (561) 32-9162 Fax: (561) 32-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park

More information

EM330 Installation and use instructions Three-phase energy analyzer for indirect connection (5A) with Modbus, pulse or M-Bus interface

EM330 Installation and use instructions Three-phase energy analyzer for indirect connection (5A) with Modbus, pulse or M-Bus interface EM330 Instaation and use instructions Three-phase energy anayzer for indirect connection (5A) with Modbus, puse or M-Bus interface Code 8021422 Genera warnings HAZARD: Live parts. Heart attack, burns and

More information

GT3D Digital Timers. 100 to 240V AC (50/60Hz), 24V AC (50/60Hz)/24V DC

GT3D Digital Timers. 100 to 240V AC (50/60Hz), 24V AC (50/60Hz)/24V DC rs G3D Series G3D rs Key features of the G3D series incude: Precise time setting using digita thumbwhee switches Eapsed or time remaining LCD dispay 6 time ranges, 16 timing functions deays up to 99.9

More information

Understanding The HA2500 Horizontal Output Load Test

Understanding The HA2500 Horizontal Output Load Test Understanding The HA2500 Horizonta Output Load Test Horizonta output stages are part of every CRT video dispay incuding cosed circuit monitors, computer monitors, video games, medica monitors, TVs. HDTVs,

More information

Electronic circuit protector ESX10-Sxxx-DC24V-1A-10A

Electronic circuit protector ESX10-Sxxx-DC24V-1A-10A Eectronic circuit protector ESX10-Sxxx-DC2V-1A-10A Description The mode ESX10-Sxxx extends our product group of eectronic overcurrent protection devices for DC 2 V appications. At a width of ony 12.5mm

More information

MODEL: M5CTC SEN TRONIC AG

MODEL: M5CTC SEN TRONIC AG MODE: M5CTC Super-mini Termina Boc Signa Conditioners M5-UNIT CT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on

More information

Slim-line Aluminium Roofs Assembly Guide

Slim-line Aluminium Roofs Assembly Guide Sim-ine Auminium Roofs Assemby Guide Contents Bonded fush gazed roofs Page 3 Singe section of gass Page 4 Singe square with opener Page 5 Mutipe gass panes Page 6 Instaing Openers Page 10 Timber Kerb For

More information

COMDIAL. Digital Telephone System Industry-Standard Telephone. User s Guide (Interfaced through the ATI-D)

COMDIAL. Digital Telephone System Industry-Standard Telephone. User s Guide (Interfaced through the ATI-D) COMDIAL Digita Teephone System Industry-Standard Teephone User s Guide (Interfaced through the ATI-D) This user s guide appies to Industry Standard Singe Line Teephones, such as the Comdia 2500-xx (when

More information

Series. Quite simply, the best in insulation! C.A 6521 C.A 6523 C.A 6525 C.A 6531 C.A Megohmmeters

Series. Quite simply, the best in insulation! C.A 6521 C.A 6523 C.A 6525 C.A 6531 C.A Megohmmeters Quite simpy, the best in insuation! Series C.A 6521 C.A 6523 C.A 6525 C.A 6531 C.A 6533 Megohmmeters Twin digita-anaogue dispay Giant back-it screen Battery powered for hours Programmabe threshod aarms

More information

KW8M. Toward energy savings. Visualization. Makes us more ecological! Eco-POWER METER 1A/5A CT Input type

KW8M. Toward energy savings. Visualization. Makes us more ecological! Eco-POWER METER 1A/5A CT Input type WM co-powr MTR A/A CT Input type Visuaization Toward energy savings Maes us more ecoogica! Direct input of secondary side A/A CT Direct input from secondary side A/A type domestic and overseas CTs. Dedicated

More information

WS2812 Intelligent control LED integrated light source

WS2812 Intelligent control LED integrated light source Features and Benefits Contro circuit and RGB chip are integrated in a package of 5050 components, form a compete contro of pixe point. Buit-in signa reshaping circuit, after wave reshaping to the next

More information

Handheld Cable & Antenna Analyzer R&S ZVH Product Introduction Matthias Roski application engineer

Handheld Cable & Antenna Analyzer R&S ZVH Product Introduction Matthias Roski application engineer Handhed Cabe & Antenna Anayzer R&S ZVH Product Introduction Matthias Roski appication engineer Handhed Cabe & Antenna Anayzer R&S ZVH Appication Area Antenna and Cabe Instaation of Transmitter Stations

More information

Operation Guide

Operation Guide MO0806-E Getting cquainted Congratuations upon your seection of this CSIO watch. To get the most out of your purchase, be sure to carefuy read this manua and keep it on hand for ater reference when necessary.

More information

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5] Super-mini Signa Conditioners Mini-M Series AC CURRENT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on type

More information

MODEL: R3-WT4. Remote I/O R3 Series. [4] OPTIONS blank: none /Q: With options (specify the specification) AC POWER INPUT MODULE (4 input circuits)

MODEL: R3-WT4. Remote I/O R3 Series. [4] OPTIONS blank: none /Q: With options (specify the specification) AC POWER INPUT MODULE (4 input circuits) MODE: R-WT Remote I/O R Series AC POWER MODUE ( input circuits). (.) (.) [] OPTIONS ban: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detai, refer to M-System's

More information

Operation Guide 4765

Operation Guide 4765 MO0705-EA Operation Guide 4765 Getting Acquainted Congratuations upon your seection of this CASIO watch. To get the most out of your purchase, be sure to read this manua carefuy. Keep the watch exposed

More information

Operation Guide 5040

Operation Guide 5040 MO0905-A Operation Guide 5040 Getting Acquainted ongratuations upon your seection of this ASIO watch. To get the most out of your purchase, be sure to read this manua carefuy. This watch does not have

More information

A2000 Multifunctional Power Meter

A2000 Multifunctional Power Meter A2 3-348-98-3 16/2.8 Measurement of current, votage, active, reactive and apparent power, power factor, active and reactive energy, harmonic distortion and harmonics Precision measured vaues with error

More information

Assembly Instructions. JPM-1 Just Pure Magic Adjustable Printer Stand

Assembly Instructions. JPM-1 Just Pure Magic Adjustable Printer Stand Assemby Instructions JPM-1 Just Pure Magic Adjustabe Printer Stand Just Pure Magic Printer Stand JPM-1 Part Drawing Description Qty Leg Frame 2 EA Part Drawing Description Qty Hardware List A Fat Head

More information

Configuring Onyx to print on your HEXIS media

Configuring Onyx to print on your HEXIS media Configuring Onyx to print on your HEXIS media 1. Instaing a media profie suitabe for your HEXIS printing media 1.1. Downoading the media profie 2 1.2. Importing the media profie into Onyx 3 2. Defaut setting

More information

Automatic socket guard prevents incorrect connection of the measuring wires and protects both user and device.

Automatic socket guard prevents incorrect connection of the measuring wires and protects both user and device. Digita Mutimeter + Signa Generator UNIGOR 330, 355 Precision mutimeter (V, A, db, W, F, Hz, C/ F) Resoution 10µV-10nA-10mW-1pF-0,1 C-0,01Hz Quartz cock for rea-time recording Signa generator Standard caibration

More information

Energy Measurement and Management MT MD Multifunction meters with load profile

Energy Measurement and Management MT MD Multifunction meters with load profile Energy Measurement and Management MT851... MD851... Mutifunction meters with oad profie The MT851 / MD851 eectronic mutifunction eectricity meters are designed for metering of active energy in two directions,

More information

Simple operation due to clear operation system

Simple operation due to clear operation system 57 Digita Sensor SERIES Reated Information Genera terms and conditions... F-7 Gossary of terms / Genera precautions... P.359~ / P.45 Sensor seection guide... P.3~ seection... P.5~ PHOTO PHOTO Conforming

More information

NGRM700. Neutral Grounding Resistor Monitor

NGRM700. Neutral Grounding Resistor Monitor M700 eutra Grounding Resistor Monitor M700_D00292_02_D_XXE/07.2018 M700 eutra Grounding Resistor Monitor Product description The M700 is ony intended for use in high-resistance grounded systems. In these

More information

Universal Measuring Device UMG96L Operating Instructions

Universal Measuring Device UMG96L Operating Instructions Universa Measuring Device UMG96L Operating Instructions Brief instructions see ast page Mean vaue -N / - -N / - -N / - Programming mode Sum measurement Phase to phase Password Votage transformer Current

More information

Important Product Information QLX-D LICENSING INFORMATION. Information to the user. Wireless System

Important Product Information QLX-D LICENSING INFORMATION. Information to the user. Wireless System QLX-D Wireess System MPORTANT SAFETY NSTRUCTONS 1. READ these instructions. 2. KEEP these instructions. 3. HEED a warnings. 4. FOLLOW a instructions. 5. DO NOT use this apparatus near water. 6. CLEAN ONLY

More information

MODEL: R3-WT4B. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MODEL: R3-WT4B. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series MODEL: R-WTB Remote I/O R Series AC POWER MODULE ( input circuits, camp-on current sensor type CLSB use). (.) (.) (.) mm (inch) MODEL: R-WTB[][][][] ORDERING INFORMATION Code number: R-WTB[][][][] Specify

More information

Firefighter Switch with Arc Fault Detection PVSEC-...-AF1

Firefighter Switch with Arc Fault Detection PVSEC-...-AF1 Firefighter Switch with Arc Faut Detection PVSEC... Description The term firefighter switch indicates a remotey controabe DC Disconnect with which the DC side of a photovotaic system in proximity of the

More information

DX-40 Lynx Panel Meter 4 DIGIT 0.8 LED DX-45 Lynx Panel Meter 4 1/2 DIGIT 0.56 LED Both in a 1/8 DIN Case

DX-40 Lynx Panel Meter 4 DIGIT 0.8 LED DX-45 Lynx Panel Meter 4 1/2 DIGIT 0.56 LED Both in a 1/8 DIN Case E46978 Genera Features Large dispay DX-4.8 red or green LED FAMILY DX-4 Lynx Pane Meter 4 DIGIT.8 LED DX-45 Lynx Pane Meter 4 1/ DIGIT.56 LED Both in a 1/8 DIN Case A versatie, standard and arge dispay,

More information

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5] MODE: M5CTC Super-mini Termina Boc Signa Conditioners M5-UNIT CT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on

More information

Method of Build. Kameo 75. Love the space you re in.

Method of Build. Kameo 75. Love the space you re in. Kameo 75 - a 75mm radius edge trim system in a stee stud and pasterboard construction with pre-assembed window frames Kameo 75 Method of Buid Love the space you re in. Kameo-75 - partitioning system Method

More information

DX-40 Lynx Panel Meter 4 DIGIT 0.8 LED DX-45 Lynx Panel Meter 4 1/2 DIGIT 0.56 LED Both in a 1/8 DIN Case

DX-40 Lynx Panel Meter 4 DIGIT 0.8 LED DX-45 Lynx Panel Meter 4 1/2 DIGIT 0.56 LED Both in a 1/8 DIN Case FAMILY DX-4 Lynx Pane Meter 4 DIGIT.8 LED DX-45 Lynx Pane Meter 4 1/ DIGIT.56 LED Both in a 1/8 DIN Case Large dispay DX-4.8 red or green LED Genera Features Externa transmitters or signa conditioners

More information

Rectangular-shaped Inductive Proximity Sensor. website

Rectangular-shaped Inductive Proximity Sensor. website 785 Rectanguar-shaped Inductive Proximity Sensor SERIES Reated Information Genera terms and conditions... F-3 Gossary of terms... P.157~ guide... P.781~ Genera precautions... P.1579~ PHOTO PHOTO IGHT FOW

More information

LTC /LTC V Microprocessor Supervisory Circuits APPLICATIONS TYPICAL APPLICATION

LTC /LTC V Microprocessor Supervisory Circuits APPLICATIONS TYPICAL APPLICATION Microprocessor Supervisory Circuits FEATURES n Guaranteed Reset Assertion at = 1 n Pin Compatibe with LTC69/LTC695 for Systems n 2μA Typica Suppy Current n Fast (ns Typ) Onboard Gating of RAM Chip Enabe

More information

HV SERIES. Uninterruptible Power Systems. Designed to be used with linear or non-linear loads including:

HV SERIES. Uninterruptible Power Systems. Designed to be used with linear or non-linear loads including: 7.5 kva to 25 kva HV SERIES Uninterruptibe Power Systems Designed to be used with inear or non-inear oads incuding: Distributive Networks Extensive LAN / WAN Systems Midrange Computing Information Technoogy

More information

SURGE ARRESTERS FOR CABLE SHEATH PREVENTING POWER LOSSES IN M.V. NETWORKS

SURGE ARRESTERS FOR CABLE SHEATH PREVENTING POWER LOSSES IN M.V. NETWORKS SURGE ARRESTERS FOR CABLE SHEATH PREVENTING POWER LOSSES IN M.V. NETWORKS A. Heiß Energie-AG (EAM), Kasse G. Bazer Darmstadt University of Technoogy O. Schmitt ABB Caor Emag Schatanagen, Mannheim B. Richter

More information

MODEL: LSMT4 [2] INPUT 1: 480 V / 1 A AC 2: 480 V / 5 A AC. Power Transducer Series

MODEL: LSMT4 [2] INPUT 1: 480 V / 1 A AC 2: 480 V / 5 A AC. Power Transducer Series Power Transducer Series MUTI POWER TRASDUCER Functions & Features Measures simutaneousy severa variabes of a heavycurrent power system: current, votage, active, reactive and apparent power, active and

More information

RED LION CONTROLS MODEL TCU - TEMPERATURE CONTROL UNIT

RED LION CONTROLS MODEL TCU - TEMPERATURE CONTROL UNIT RED LION CONTROLS INTERNATIONAL HEADQUARTERS EUROPEAN HEADQUARTERS 0 Wiow Springs Circe, York, Pa. 740, (77) 767-65 FAX: (77) 764-0839 89 Pymouth Road, Sough, Berkshire SL 4LP Web site- http://www.redion-contros.com

More information

WIRELESS SYSTEM QLX-D USER GUIDE Shure Incorporated 27A22351 (Rev. 1)

WIRELESS SYSTEM QLX-D USER GUIDE Shure Incorporated 27A22351 (Rev. 1) WRELESS SYSTEM QLX-D USER GUDE 2014 Shure ncorporated 27A22351 (Rev. 1) MPORTANT SAFETY NSTRUCTONS 1. READ these instructions. 2. KEEP these instructions. 3. HEED a warnings. 4. FOLLOW a instructions.

More information

Operation Guide 5031

Operation Guide 5031 MO090-A Operation Guide 0 Getting Acquainted ongratuations upon your seection of this ASIO watch. To get the most out of your purchase, be sure to read this manua carefuy. This watch does not have a city

More information

Operation Guide 4766

Operation Guide 4766 MO0706-EA Operation Guide 4766 Getting Acquainted Congratuations upon your seection of this CASIO watch. To get the most out of your purchase, be sure to read this manua carefuy. This watch does not have

More information

Electronic Circuit Protector ESX10-T.-DC 24 V

Electronic Circuit Protector ESX10-T.-DC 24 V Eectronic Circuit Protector ESX0-T.-DC 2 V Description The mode ESX0-T extends our product group of eectronic overcurrent protection devices for DC 2 V appications. At a width of ony 2.5 mm it provides

More information

Firefighter Switch with Arc Fault Detection PVSEC-...-AF...

Firefighter Switch with Arc Fault Detection PVSEC-...-AF... Firefighter Switch with Arc Faut Detection PVSEC... Description The term firefighter switch indicates a remotey controabe DC Disconnect with which the DC side of a photovotaic system in proximity of the

More information

LTC4365 UV, OV and Reverse Supply Protection Controller APPLICATIONS TYPICAL APPLICATION

LTC4365 UV, OV and Reverse Supply Protection Controller APPLICATIONS TYPICAL APPLICATION , and Reverse Suppy Protection Controer FEATURES n Wide Operating Votage Range: 2.5V to 34V n Overvotage Protection to 6V n Reverse Suppy Protection to 4V n Bocks 5Hz and 6Hz AC Power n No Input Capacitor

More information

Rectangular-shaped Inductive Proximity Sensor GX-F/H SERIES

Rectangular-shaped Inductive Proximity Sensor GX-F/H SERIES 87 PHOTO PHOTO IGHT FOW PARTICUAR Rectanguar-shaped Inductive Proximity Sensor SERIES Reated Information Genera terms and conditions... F-7 Gossary of terms... P.18~ Sensor seection guide... P.83~ Genera

More information

7 DO NOT run down shade cloth outside of the Side Channels. Headbox Height + Hembar** ¼ (6mm) on Both Sides. 2¼ (57mm)

7 DO NOT run down shade cloth outside of the Side Channels. Headbox Height + Hembar** ¼ (6mm) on Both Sides. 2¼ (57mm) Instaation Instructions Futureguard FexShade Zip by Draper READ BEFORE YOU BEGIN Inspect a boxes to make sure you have received the proper parts. 2 Open cartons engthwise. 3 A hardware must be instaed

More information

Commercially-available connectors are used so that lead time and spare part numbers can both be reduced Conventional lead time

Commercially-available connectors are used so that lead time and spare part numbers can both be reduced Conventional lead time 3 PHOTO PHOTO Digita Sensor SERIES Reated Information Genera terms and conditions... P. Sensor seection guide...p.~ / P.6~ Gossary of terms / Genera precautions...p.983~ / P.986~ seection... P.63~ Conforming

More information

LBI Mobile Communications. EDACS TM Jessica. PBX Gateway. Operator s Manual

LBI Mobile Communications. EDACS TM Jessica. PBX Gateway. Operator s Manual Mobie Communications EDACS TM Jessica PBX Gateway Operator s Manua TABLE OF CONTENTS 1. SCOPE... 3 2. QUICK USAGE GUIDE... 4 2.1. Making Phone Cas From An EDACS Radio... 4 2.2. Caing EDACS Radios From

More information

Configuring RolandVersaWorks to print on your HEXIS media

Configuring RolandVersaWorks to print on your HEXIS media PRINTING DIVISION Product Buetin N 4 Configuring RoandVersaWorks to print on your HEXIS media 1. Instaing a media profie suitabe for your HEXIS printing media 1.1. Downoading the media profie 2 1.2. Importing

More information

RAD250 Nothing Comes Close to a Cobra

RAD250 Nothing Comes Close to a Cobra Operating Instructions The obra ine of quaity products incudes: B Radios Dash ams Radar Detectors Marine VHF Radios Power Inverters Accessories RADAR/LASER PROTETION RAD250 Nothing omes ose to a obra Introduction

More information

Development of a LabVIEW-based test facility for standalone PV systems

Development of a LabVIEW-based test facility for standalone PV systems Deveopment of a LabVIEW-based test faciity for standaone PV systems Aex See Kok Bin, Shen Weixiang, Ong Kok Seng, Saravanan Ramanathan and Low I-Wern Monash University Maaysia, Schoo of Engineering No.2,

More information

R-V302K OWNER S MANUAL. Natural Sound AV Receiver. Thank you for selecting this YAMAHA AV receiver.

R-V302K OWNER S MANUAL. Natural Sound AV Receiver. Thank you for selecting this YAMAHA AV receiver. R R-VK Natura Sound AV Receiver Thank you for seecting this YAMAHA AV receiver. OWNER S MANUAL Suppied Accessories... Features... Caution... Profie of This Unit...5 Speaker Setup...6 Connections...7 Contros

More information

Method of Build. ORBIS Single Glazed. Komfort Installation KOMFORT

Method of Build. ORBIS Single Glazed. Komfort Installation KOMFORT KOMFORT WORKSPACE Orbis singe gazed - a muion free crysta cear dry vertica jointed system with square auminium sections Method of Buid Komfort Instaation Love the space you re in. June 2012 Index Section

More information

LT8710 Synchronous SEPIC/ Inverting/Boost Controller with Output Current Control. Applications. Typical Application

LT8710 Synchronous SEPIC/ Inverting/Boost Controller with Output Current Control. Applications. Typical Application Features n Wide Input Range: 4.5V to 8V n Rai-to-Rai Output Current Monitor and Contro n Input Votage Reguation for High Impedance Inputs n C/1 or Power Good Indication Pin n MODE Pin for Forced CCM or

More information

ISOSCAN EDS440/441. Device variants. Alarm messages are directly indicated on the device display

ISOSCAN EDS440/441. Device variants. Alarm messages are directly indicated on the device display EDS/ Insuation faut ocators for ocaisation of insuation fauts in unearthed DC, AC and three-phase power suppy systems (IT systems) EDS-_D D_XXEN/. EDS/ Insuation faut ocators for ocaisation of insuation

More information

ThermaData Logger DATA-LOGGERS. temperature recording thermometers.

ThermaData Logger DATA-LOGGERS. temperature recording thermometers. ThermaData Logger temperature recording thermometers waterproof housing offering IP66/67 protection temperature range or 125 C resoution 0.1 C, high accuracy ±0.5 C meets EN 12830, S & T, C & D, 1 The

More information

Rectangular-shaped Inductive Proximity Sensor.

Rectangular-shaped Inductive Proximity Sensor. 71 PHOTOEECTRIC PHOTOEECTRIC IGHT FOW PARTICUAR USE SIMPE MEASUREMENT STATIC CONTRO Rectanguar-shaped Inductive Proximity Sensor SERIES Reated Information Genera terms and conditions... F-17 Gossary of

More information

LTC Linear Phase 8th Order Lowpass Filter FEATURES APPLICATIONS DESCRIPTION TYPICAL APPLICATION

LTC Linear Phase 8th Order Lowpass Filter FEATURES APPLICATIONS DESCRIPTION TYPICAL APPLICATION LTC69-7 Linear Phase 8th Order Lowpass Fiter FEATURES n 8th Order, Linear Phase Fiter in SO-8 Package n Raised Cosine Ampitude Response n 43 Attenuation at 2 f CUTOFF n Wideband Noise: 4μV RMS n Operates

More information

LT6100 Precision, Gain Selectable High Side Current Sense Amplifier. Applications. Typical Application

LT6100 Precision, Gain Selectable High Side Current Sense Amplifier. Applications. Typical Application Features n Input Offset otage: 3µ (Max) n Sense Inputs Up to 8 n.5 Gain Accuracy n Pin Seectabe Gain:, 2.5, 2, 25,, 5/ n Separate Power Suppy: 2.7 to 36 n Operating Current: 6µA n Sense Input Current (

More information

dtrans ph 01 Microprocessor transmitter/ controller for ph value or redox potential

dtrans ph 01 Microprocessor transmitter/ controller for ph value or redox potential M. K. Juchheim GmbH & Co UK USA Jumo nstrument Co. Ltd. Jumo Process Contro nc. 36035 Fuda, Germany Tempe Bank, Riverway 735 Fox Chase Phone (0661) 6003-0 Harow, Essex CM20 2TT Coatesvie, PA 19320 Fax

More information

\[7 BROADS, ANTENI 2-6 Mt-

\[7 BROADS, ANTENI 2-6 Mt- E.ECTRONCS TECHNCAN 3 & 2 VOL. 1 to each antenna couper (1) a.c. to operate the cooing fans which remove the heat generated during operation and (2) d.c. to operate the contro and protective circuits.

More information

RX-V300K OWNER S MANUAL. Natural Sound AV Receiver. Thank you for selecting this YAMAHA AV receiver.

RX-V300K OWNER S MANUAL. Natural Sound AV Receiver. Thank you for selecting this YAMAHA AV receiver. R RX-VK Natura Sound AV Receiver Thank you for seecting this YAMAHA AV receiver. OWNER S MANUAL SAFETY INSTRUCTIONS CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

More information

Implementation of PV and PIV Control for Position Control of Servo Motor

Implementation of PV and PIV Control for Position Control of Servo Motor IJSRD - Internationa Journa for Scientific Research & Deveopment Vo. 5, Issue 1, 2017 ISSN (onine): 2321-0613 Impementation of PV and PIV Contro for Position Contro of Servo Motor J.Priya 1 R.Rambrintha

More information

LTC2915/LTC2916 Voltage Supervisor with 27 Selectable Thresholds DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION

LTC2915/LTC2916 Voltage Supervisor with 27 Selectable Thresholds DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION FEATURES n 9 Seectabe Suppy otages 12,, 3.3, 2., 1.8 1., 1.2, 1., +ADJ (.) n 3 Seectabe Toerances %, 1%, 1% () n Manua Reset Input (LTC2916) n 1. to. Suppy Operation n 6.2 Shunt Reguator for High otage

More information

LTC2607/LTC2617/LTC /14-/12-Bit Dual Rail-to-Rail DACs with I 2 C Interface. Applications. Block Diagram

LTC2607/LTC2617/LTC /14-/12-Bit Dual Rail-to-Rail DACs with I 2 C Interface. Applications. Block Diagram Features n Smaest Pin-Compatibe Dua DACs: LTC267: 16 Bits LTC2617: 14 Bits LTC2627: 12 Bits n Guaranteed Monotonic Over Temperature n 27 Seectabe Addresses n 4kHz I 2 C Interface n Wide 2.7V to 5.5V Suppy

More information

General terms and conditions... F-7 Glossary of terms / General precautions... P.1455~ / P panasonic.net/id/pidsx/global

General terms and conditions... F-7 Glossary of terms / General precautions... P.1455~ / P panasonic.net/id/pidsx/global 9 Digita Sensor FX- SERIES Reated Information Genera terms and conditions... F-7 Gossary of terms / Genera precautions... P.455~ / P.5 Sensor seection guide... P.3~ seection... P.5~ PHOTO PHOTO IGHT FOW

More information

Powerfully simple event analysis software

Powerfully simple event analysis software synchrowave Event Software Powerfuy simpe event anaysis software Diagnose reay behavior during a power system faut. Time-aign event reports from mutipe reays for comparison and anaysis. Create custom cacuations,

More information

KOMFORT. Klassic - a radius edge veneered trim system in a steel stud and plasterboard construction with glazing options. Klassic.

KOMFORT. Klassic - a radius edge veneered trim system in a steel stud and plasterboard construction with glazing options. Klassic. KOMFORT Kassic - a radius edge veneered trim system in a stee stud and pasterboard construction with gazing options Kassic Method of Buid Love the space you re in. February 2013 Kassic - partitioning system

More information

METRAHIT 27M and METRAHIT 27I Milliohm Resistance Meter and Digital Multimeter, Insulation Tester and Data Logger

METRAHIT 27M and METRAHIT 27I Milliohm Resistance Meter and Digital Multimeter, Insulation Tester and Data Logger 3-349-206-03 8/2.12 The METRA HIT 27M is a compact miiohm resistance meter pus mutimeter and thermometer for the measurement of ow-vaue contact resistance on aircraft outer skins (ightning protection,

More information

LT6203X High Temperature 175 C Dual 100MHz, Rail-to-Rail Input and Output, Ultralow 1.9nV/ Hz Noise, Low Power Op Amp Description

LT6203X High Temperature 175 C Dual 100MHz, Rail-to-Rail Input and Output, Ultralow 1.9nV/ Hz Noise, Low Power Op Amp Description Features Appications LT3X High Temperature 7 C Dua MHz, Rai-to-Rai Input and Output, Utraow.9nV/ Hz Noise, Low Power Op Amp Description Extreme High Temperature Operation: C to 7 C Low Noise Votage:.9nV/

More information

LTC4151 High Voltage I 2 C Current and Voltage Monitor DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION

LTC4151 High Voltage I 2 C Current and Voltage Monitor DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION FEATURES n Wide Operating Votage Range: V to V n -Bit Resoution for Both Current and Votages n I C Interface n Additiona ADC Input Monitors an Externa Votage n Continuous Scan and Snapshot Modes n Shutdown

More information

TO DIODE GND BG2 SW2 BOOST2 TG2 CSPOUT CSNOUT EXTV CC FBOUT INTV CC GATEV CC SRVO_FBIN SRVO_FBOUT SRVO_IIN SRVO_IOUT IMON_IN IMON_OUT

TO DIODE GND BG2 SW2 BOOST2 TG2 CSPOUT CSNOUT EXTV CC FBOUT INTV CC GATEV CC SRVO_FBIN SRVO_FBOUT SRVO_IIN SRVO_IOUT IMON_IN IMON_OUT Features nn nn nn nn nn nn nn nn nn nn Singe Inductor Aows Above, Beow, or Equa to Reguated Range 2.8V (Need EXTV CC > 6.4V) to 8V Range: 1.3V to 8V Quad N-Channe MOSFET Gate Drivers Synchronous Rectification:

More information

ISOSCAN EDS440/441. Device variants. Alarm messages are directly indicated on the device display

ISOSCAN EDS440/441. Device variants. Alarm messages are directly indicated on the device display EDS/ Insuation faut ocators for ocaisation of insuation fauts in unearthed DC, AC and three-phase power suppy systems (IT systems) EDSxx_D D_XXEN/. EDS/ Insuation faut ocators for ocaisation of insuation

More information

LTC kHz Continuous Time, Linear Phase Lowpass Filter FEATURES DESCRIPTION APPLICATIONS TYPICAL APPLICATION

LTC kHz Continuous Time, Linear Phase Lowpass Filter FEATURES DESCRIPTION APPLICATIONS TYPICAL APPLICATION FEATURES DESCRIPTION n th Order, 0kHz Linear Phase Fiter in an SO- n Differentia Inputs and Outputs n Operates on a Singe or a ± Suppy n Low Offset: m Typica n db THD and SNR n db SNR n Shutdown Mode n

More information

NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63

NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63 ETWOR AAYSER MPR-50 / MPR-52S / MPR-60S / Modbus / Ethernet Gateway Genera MPR-50 : etwor Anayser. MPR-52S : etwor Anayser with THD measurement, R S-45 (MODBUS) and Aarm Contact. MPR-60S: etwor Anayser

More information

ABSOLUTE MAXIMUM RATINGS Votage....3V to 9V SENSE +, SENSE Votages... 1V or.3v to +.3V, ADR Votages....3V to 9V, SHDN, SDAO Votages....3V to V, SDA, S

ABSOLUTE MAXIMUM RATINGS Votage....3V to 9V SENSE +, SENSE Votages... 1V or.3v to +.3V, ADR Votages....3V to 9V, SHDN, SDAO Votages....3V to V, SDA, S FEATURES n Wide Operating Votage Range: 7V to V n 1-Bit Resoution for Both Current and Votages n I C Interface n Additiona ADC Input Monitors an Externa Votage n Continuous Scan and Snapshot Modes n Shutdown

More information

Insulation. First Issue August See rear cover for applicable countries. Phenolic System PRODUCT CATALOGUE. Low Energy Low Carbon Buildings

Insulation. First Issue August See rear cover for applicable countries. Phenolic System PRODUCT CATALOGUE. Low Energy Low Carbon Buildings Insuation First Issue August 2017 See rear cover for appicabe countries PRODUCT CATALOGUE Phenoic System Low Energy Low Carbon Buidings Introduction Overview The heating, ventiation and air conditioning

More information

LTC2656 Octal 16-/12-Bit Rail-to-Rail DACs with 10ppm/ C Max Reference DESCRIPTION FEATURES APPLICATIONS BLOCK DIAGRAM

LTC2656 Octal 16-/12-Bit Rail-to-Rail DACs with 10ppm/ C Max Reference DESCRIPTION FEATURES APPLICATIONS BLOCK DIAGRAM FEATURES n Precision 1ppm/ C Max Reference n Maximum INL Error: ±4LSB at 16 Bits n Guaranteed Monotonic over Temperature n Seectabe Interna or Externa Reference n 2.7V to 5.5V Suppy Range (LTC2656-L) n

More information

Nanopower Buck-Boost DC/DC with Energy Harvesting Battery Charger APPLICATIONS TYPICAL APPLICATION

Nanopower Buck-Boost DC/DC with Energy Harvesting Battery Charger APPLICATIONS TYPICAL APPLICATION FEATURES nn nn nn nn nn nn nn nn nn nn Dua Input, Singe Output DC/DCs with Input Prioritizer nn Energy Harvesting Input: 3. to 19 Buck DC/DC nn Battery Input: Up to 4.2 Buck-Boost DC/DC 1mA Shunt Battery

More information

Gamma 20 Analog-Digital Multimeter

Gamma 20 Analog-Digital Multimeter User Manua Gamma 2 Anaog-Digita Mutimeter RE:/2/11/214 PREISION INSTRUMENTATION Sifam Tinsey Instrumentation 15, reekside iage Drive, Suite No 81,Kennesaw, Georgia 144 ontact Number: +1.44.76.49 eb: www.sifamtinsey.com

More information

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator SERIES Electronic Preset Counter Instruction Manual Please note that misuse of this device may lead to injury to the user or damage to the device. Please observe all safety precautions and warnings in

More information

Series 700A Power Processor

Series 700A Power Processor Series 700A Power Processor 5 25 SINGLE PHASE 10 500 THREE PHASE VOLTAGE REGULATION, ISOLATION, AND POWER DISTRIBUTION FOR CLEAN, SPIKE-FREE, STABLE VOLTAGE When Power Quaity Is A Must And Faiure Is Not

More information

High Current Hot Swap Controller with I 2 C Compatible Monitoring. Applications. Typical Application

High Current Hot Swap Controller with I 2 C Compatible Monitoring. Applications. Typical Application Features nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn Appications nn nn nn nn Typica Appication Description High Current Hot Swap Controer with I 2 C Compatibe Monitoring Aows Safe Board Insertion

More information

LT V Synchronous 4-Switch Buck-Boost DC/DC Slave Controller for LT8708 Multiphase System

LT V Synchronous 4-Switch Buck-Boost DC/DC Slave Controller for LT8708 Multiphase System 80V Synchronous 4-Switch Buck-Boost DC/DC Save Controer for LT8708 Mutiphase System FEATURES nn nn nn nn nn nn nn nn APPLICATIONS nn nn nn Save Chip of LT8708 to Deiver Additiona Power Good Current Matching

More information

LTC2938/LTC2939 Configurable 4- and 6-Supply Monitors with Watchdog Timer FEATURES DESCRIPTION APPLICATIONS TYPICAL APPLICATION

LTC2938/LTC2939 Configurable 4- and 6-Supply Monitors with Watchdog Timer FEATURES DESCRIPTION APPLICATIONS TYPICAL APPLICATION Configurabe 4- and 6-Suppy Monitors with Watchdog Timer FEATURES n Simutaneousy Monitors Four (LTC2938) or Six Suppies (LTC2939) n Sixteen User-Seectabe Combinations of 5V, 3.3V, 2.5V, 1.8V, 1.5V, 1.2V

More information

RX-V492 RX-V392. Natural Sound AV Receiver Récepteur audiovisuel Son Naturel Receptor AV de Sonido Natural

RX-V492 RX-V392. Natural Sound AV Receiver Récepteur audiovisuel Son Naturel Receptor AV de Sonido Natural RX-V9 RX-V9 Natura Sound AV Receiver Récepteur audiovisue Son Nature Receptor AV de Sonido Natura Thank you for seecting this YAMAHA AV receiver. Nous vous remercions d avoir porté votre choix sur ce récepteur

More information

LT1630/LT MHz, 10V/µs, Dual/Quad Rail-to-Rail Input and Output Precision Op Amps. Applications. Typical Application

LT1630/LT MHz, 10V/µs, Dual/Quad Rail-to-Rail Input and Output Precision Op Amps. Applications. Typical Application Features n Gain-Bandwidth Product: 3MHz n Sew Rate: V/µs n Low Suppy Current per Ampifier: 3.5mA n Input Common Mode Range Incudes Both Rais n Output Swings Rai-to-Rai n Input Offset Votage, Rai-to-Rai:

More information

LT Dual Very Low Noise, Differential Amplifi er and 15MHz Lowpass Filter DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION

LT Dual Very Low Noise, Differential Amplifi er and 15MHz Lowpass Filter DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION FEATURES n Dua Differentia Ampifi er with MHz Lowpass Fiters th Order Fiters Approximates Chebyshev Response Guaranteed Phase and Gain Matching Resistor-Programmabe Differentia Gain n 7 Signa-to-Noise

More information

Provides exact fault location to one span

Provides exact fault location to one span TWS Mark VI Traveing wave faut ocator Provides exact faut ocation to one span Reduce down time by getting to the faut site faster Track intermittent sef cearing fauts and focus maintenance at the right

More information

Device handbook APLUS-LED

Device handbook APLUS-LED Device handbook APLUS-LED Operating Instructions APLUS with LED dispay or without dispay 157 679-19 (PM 1000357 000 01) 04/2016 Camie Bauer Metrawatt AG Aargauerstrasse 7 CH-5610 Wohen / Switzerand Phone:

More information

F Series SINGLE-PHASE DIGITAL SWITCHBOARD MONITORS FVA, FVD, FAA, FAD, FF, FT MODELS

F Series SINGLE-PHASE DIGITAL SWITCHBOARD MONITORS FVA, FVD, FAA, FAD, FF, FT MODELS F Series SINGE-PHASE DIGITA SWITCHBOARD MONITORS FVA, FVD, FAA, FAD, FF, FT MODES User's Manual Revision 1.9 September 22, 2017 e Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590

More information

Device handbook APLUS-TFT

Device handbook APLUS-TFT Device handbook APLUS-TFT Operating Instructions APLUS with TFT dispay 173 013-05 (PM 1000360 000 01) 04/2016 Camie Bauer Metrawatt AG Aargauerstrasse 7 CH-5610 Wohen / Switzerand Phone: +41 56 618 21

More information

LT1970A 500mA Power Op Amp with Adjustable Precision Current Limit FEATURES DESCRIPTION APPLICATIONS TYPICAL APPLICATION

LT1970A 500mA Power Op Amp with Adjustable Precision Current Limit FEATURES DESCRIPTION APPLICATIONS TYPICAL APPLICATION FEATURES n ±5mA Minimum Output Current n Independent Adjustment of Source and Sink Current Limits n 1% Current Limit Accuracy n Improved Reactive Load Driving Stabiity n Operates with Singe or Spit Suppies

More information

FEATURES APPLICATIONS TYPICAL APPLICATION

FEATURES APPLICATIONS TYPICAL APPLICATION FEATURES n Reguates Whie Sourcing or Sinking Current n Provides Termination for up to 27 SCSI Lines n μa Quiescent Current n Utraow Power Shutdown Mode n Current Limit and Therma Shutdown Protection n

More information