Endoscopic Suturing Devices

Size: px
Start display at page:

Download "Endoscopic Suturing Devices"

Transcription

1 Session IV UGS-IV: Emerging but rarely Used Treatment Options in Asia Endoscopic Suturing Devices Khek-Yu Ho, M.D. Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore Introduction Suturing is a necessary step in any surgical operation. In flexible endoscopic surgery within and beyond the gastrointestinal tract, the task of suturing is more difficult due to limited working space and the non rigidity of the endoscope s shaft making it impossible to provide a stable base for surgical manoeuvres. Besides, tactile feel is lost in the flexible endoscopic approach. Unlike in laparoscopic procedures, performing suturing and tying of knots endoscopically is a very tedious process requiring high manual dexterity and excellent hand eye coordination. Endoscopic suturing devices currently available for use in gastrointestinal surgery are too complex for the average endoscopist to handle, requiring much training with long learning curves. While most of the earlier endoscopic suturing devices developed for upper gastrointestinal tract uses were aimed for procedures such as fundoplication, recent developments in natural orifice translumenal endoscopic surgery (NOTES) have prompted designs suitable for transluminal surgical applications. In the absence of better visceral closure devices, most early trials in NOTES have resorted to the use of endoscopic clips or tissue anchors to reinforce closures of visceral perforations. Better, more dextrous and yet easy to handle endoscopic suturing devices are awaited. Development of endoscopic suturing devices to date In contrast to earlier suturing/stapling devices designed for the treatment of gastroesophageal reflux disease and obesity, innovations of endoscopic suturing devices specifically for use in flexible endoscopic surgery had only been in progress for at most a decade. In fact, clinical trials of some of these endoscopic suturing devices debuted only in the mid 2000s, which was followed by commercialisation of the OverStitch developed by Apollo Endosurgery, Inc., Austin, TX, USA, and the InScope Tissue Apposition System developed by Ethicon Endo surgery, Cincinnati, OH, USA, for use in various types of flexible endoscopic surgery. Over the recent years, a few other newer suturing devices/systems have emerged, with most being in pre clinical evaluation stage. 1. Commercially available endoscopic suturing devices functions and applications A limited number of flexible endoscopic surgery suturing systems have been cleared by the US Food and Drug Administration (FDA) agency for clinical applications. Amongst the better known ones are the OverStitch su- 122 IDEN 2014

2 UGS-IV: Emerging but rarely Used Treatment Options in Asia turing device, the InScope Tissue Apposition System, and the g Prox Tissue Approximation Device (USGI Medical, Inc., United States), which will be described in the following paragraphs. The OverStitch suturing device is a disposable, single use suturing device designed to be front loaded onto a double channel endoscope for deployment. It employs a lateral needle passing mechanism and allows continuous or interrupted stitches to be made. Cinching capability is incorporated into the system to provide fast, secure closure of perforation without the need to tie complex surgical knots. The OverStitch can deliver multiple stitches in one single endoscopic insertion to provide secure approximation of tissue. Its curved needle design allows operator to better control the depth of suture placement. Cinching and reloading of needle can be done without the need to remove the endoscope from the stomach. Designed for single handed system control, it requires only one operator to handle the system and is suitable for use in a wide range of endoscopic application, including endoluminal tissue apposition and endoscopic closure of submucosal or full thickness mural defects. The OverStitch has been successfully applied to perform gastric full thickness suture during endoscopic mucosal resection, 1 suturing of gastric full thickness resection, 2 suturing of defects in treat and resect colonic procedures, 3 suturing of large defects in the stomach and colon left after endoscopic mucosal dissection, 4 suturing of gastric fistulas, 5 and suturing of the mucosal entry site in full novel submucosal tunnelling procedures. 6 The OverStitch has an edge over other existing suturing devices in that it is also effective for closure of larger defects. The downside is that orientation of the curved needle requires much skill and the assistance of an endoscopic grasper is required during operation. It is however generally considered complex to use and more appropriately apply for use in bigger lumens such as in the stomach rather than smaller lumens, although recent trials conducted in human have demonstrated the feasibility of its use in some colonic procedures. 3,4 The InScope Tissue Apposition System is designed for endoscopic placement of sutures and approximation of soft tissue. The system uses an endoscopic hollow bore needle and non absorbable, synthetic, polypropylene suture, and works by sequentially deploying threaded T tag through the soft tissue on each side of the gastrointestinal defect to be sewn. Suture position is maintained by means of a metal tissue anchor attached to the distal end of each suture strand. Threaded T tags placed on either side of the defect are then cinched using a component called the Knotting Element. The InScope Tissue Apposition System can be used for endoscopic treatment of a variety of defects, including ulcers and perforations. One shortcoming in the design of the system is that the operator cannot visualize the deployment of T tag from the extra luminal side of the defect, thus posing a risk of inadvertent injury to surrounding tissue or blood vessels during deployment of the tags. Preclinical studies showed the feasibility of making leak proof endoluminal closure of a 4 cm long colon perforation in 3 of 4 cases tried. 7 Subsequently, trials conducted in human demonstrated safe closure of defects by the InScope Tissue Apposition System during endoscopic polypectomy of polyps which were otherwise deemed unresectable. 8 The system is now being further developed by Ethicon Endo Surgery as part of a NOTES Toolbox specifically for use in flexible endoscopic transluminal surgery applications. The flexible g Prox Tissue Approximation Device is a multi function instrument that works on the TransPort multitasking endoscopic platform, both manufactured by USGI Medical, Inc., United States. The g Prox Tissue Approximation Device, designed to suit single operator handling, is equipped with independent torqueing capacity. To do suturing, the device is first deployed through the lumen of the TransPort endoscopy platform. Once the device is deployed at the endoscope s tip, it acts as a needle driver that delivers its propriety IDEN

3 IDEN 2014 Snowshoe Suture Anchors which are preloaded into the g Cath EZ Delivery Catheter inserted into the g Prox device. Once anchors are used up, reloading of the anchors can be performed without the need to withdraw the instrument. In contrast to the InScope Tissue Apposition System, anchor placement here is made via an off axis needle. The suture passage is thus off tangential, permitting thus full visualization of the anchor placement. This is an advantage as it mitigates the risk of inadvertent injury to adjacent tissue as may happen in blinded placement. The system is so designed that the operator can singularly control the tension of the tissue anchors and adjusts it to tighten the closure. Knot strength is quite easily achieved. The g Prox Tissue Approximation Device also has the additional functionality of acting as a tissue grasper, providing a robust grasping function and tissue manipulation capability. Pre clinical trials in animals have demonstrated excellent full thickness suturing using the system. 9 The system which is already CE marked for marketing in Europe, is now being developed as part of USGI Medical's Incisionless Operating Platform, a complete multitasking endosurgical platform designed to support the performance of intricate endoscopic endoluminal, as well as transluminal surgical procedures such as those in NOTES. 2. Emerging endoscopic suturing devices Despite the availability of various endoscopic suturing devices that can do suturing tasks as described above, there is still no perfect technological solution for consistent and reliable closures of larger mural defects such as those deliberately made in NOTES. Current commercially available systems have been found by many users to be technically complex, with some reporting finding it difficult to mount the devices correctly on the endoscope. The complexity of the applications, long learning curve, lack of equipment dexterity, and inadequate tissue closure strength are persistent issues that continue to spur innovations for better solution. Recent development of NOTES has prompted renewed interest in the development of easily deployable endoscopic suturing devices that can make sutures that are as strong, secured and reliable as hand sewn ones. Several new and promising innovations are now in proof of concept or pre clinical evaluation stage. Amongst them are: (i) a novel Korean designed prototype device featuring the capability of making successive sutures, and aptly named the successive suturing device, 10,11 and (ii) two prototypes of an interesting Japanese designed suturing system, the double arm bar suturing system and the triple arm bar suturing system. 12,13 Pre clinical evaluations of the novel successive suturing device were recently reported by Song et al (2013). The successive suturing device appears to be quite simple by construct, with three major components a needle, teel plastic tubing that holds major parts of the system, a handle plus a suction cap. 10 The protective tubing has an external diameter of 3.2 mm, making it small enough to pass through the accessory channel of a standard therapeutic endoscope. The tubing encases the main components of the device, including the transfer tube for the needle, suturing thread and accompanying biodegradable trapezoidal shaped bead which is used as anchor. The handle drives the movement between the components. To perform the suturing of a deliberate or iatrogenic defect in the wall of the stomach or gastrointestinal tract, the entire system is deployed through the accessory channel of the endoscope, and the needle is pushed through the gastric or intestinal wall. A stitch bead is deployed from the needle and it anchors a stitch on the outer surface of the wall while the needle is pulled back from inside the lumen. As beads are anchored on both sides of the incision, pulling the stitch tightens and securely closes the incision. Recently, Song et al (2013) reported their validation of the suturing efficacy of the prototypic device on Erlangen porcine stomach models, in which they compared the strength and reproduci- 124 IDEN 2014

4 UGS-IV: Emerging but rarely Used Treatment Options in Asia bility of incisions sutured by the device to that of incision sutured by hand or closed by endoclips. Deliberate incisions of 2 3 mm length were made on the anterior lower body of 30 porcine stomachs. These 30 incisions were then closed using the novel suturing device, by hand suturing or by endoclips, 10 incisions for each method of suturing. The experimental results showed that the stomachs sutured by the successive suturing device exhibited significantly higher air leakage pressure than those closed by Endoclips (P<0.05), but lower than those closed by hand suturing (P<0.05). Although the bursting pressure of device sutured stomachs was significantly smaller than that of hand sutured stomachs, it was similar to that of Endoclip closed stomachs. The suturing device took about 1 minute to complete a stitch. The experimental trials of two prototypes of a novel Japanese designed endoscopic suturing system were recently reported by Mori et al, (2013; 2014). The prototypes were named the double arm bar suturing system and triple arm bar suturing system. Although experiments are still preliminary at this stage, results indicate good potential for the novel innovations to make it to clinical applications. The triple arm bar suturing system consists of three main arms: (i) a guide needle arm, (ii) a stopper arm at the tip of the device for receiving the puncture needle arm, and (iii) a puncture needle arm. In contrast, the double arm bar suturing system has only two arms, one arm holding the puncture needle and a small hook, and the other holding the suture. In 2013, Mori et al reported the use of the triple arm bar suturing system to close twenty 5 cm incisions in resected swine stomachs. Comparing it to hand sewn stitches, they found similar maximum pulling force durability between full thickness stitches made by triple arm bar suturing system and stitches made by hand (P = 0.335). In another study, Mori et al (2014) tested the reliability of the double arm bar suturing system, and the feasibility of using it to perform endoscopic full thickness resection. Full thickness resections of 40 mm diameter were carried out on 30 swine stomachs. Based on resistance to air leak tests, they found no significant difference between hand sewn sutures and sutures made by the double arm bar suturing system (P = 0.542), indicating that the strength of sutures made by the double arm bar suturing system was as good as hand sewn ones. Whether it is single stitch and multiple stitch sutures, the sutures produced by the above prototypic suturing devices were as strong as simple, interrupted handmade sutures. 3. The Future robotic enhancement of endoscopic suturing systems Currently available endoscopic suturing devices enables suturing to be performed endoscopically but they still have functional limitations, especially when performing in confines of smaller working space, and when dealing with bigger perforations. Primarily, all these systems are mechanically driven and thus lack the motion range and functional dexterity for fast, efficient and safe operation in complex procedures such as those in NOTES. Although emerging innovations are increasingly aimed at providing better articulation in instrumental mobility, with all mechanical systems, there is limitation to the range of surgical movement of tools. Moreover, poor perception of depth with current 2D endoscopic video imaging and the lack of tactile sensation pose hurdles in the management of the orientation of tools and judgement of appropriate amount of force to apply, risking injury to tissue. To mitigate these technical challenges, the incorporation of robotics into the control of suturing and knotting function is an attractive option. Recently, the developer of the MASTER (Master And Slave Transluminal Endoscopic Robot) in Singapore demonstrated the practicality of this idea in their first ex vivo trial on robotics enabled suturing and knot tying. They demonstrated the feasibility of performing endoscopic suturing and knot tying using commercial suturing kit with robotics enablement through the MASTER, a sta- IDEN

5 IDEN 2014 Fig. 1. Robotics enabled suturing of a non perforating cut on the wall of the rectum of a pig using MASTER and Ethicon W525 suture set. Fig. 2. Robotics enabled suturing of a non perforating cut on a phantom model using MASTER and Covidien V Loc wound closure device. ble haptics enabled robotic endosurgical platform which had previously been evaluated for its performance of various endolumenal and translumenal endoscopic surgical procedures, both in animals 14,15 and in human. 16 With the assistance of the MASTER, equipped with a customized needle holder/driver with articulating jaws and a pair of graspers, suturing and knot tying was successfully performed on a phantom using a V Loc wound closure device (Covidien, Mansfield, MA, USA) (Fig. 1) and on a non perforating cut created in the rectum of a live pig using an Ethicon W525 suture set (PC 3; 16mm, 3/8 Circle Conventional Cutting) (Fig. 2) (Presentation at DDW 2014, Chicago, USA). The MASTER development team has planned to make its own customized MASTER adaptable suturing/knot tying slave effectors for truly intuitive performance of endoscopic suturing. This is part of its efforts to develop a dedicated robotics endosurgical toolbox for use on the MASTER endosurgical platform. When ready, the proposed dextrous robotics enhanced MASTER suturing/knot tying system is anticipated to contribute much to easier and safer endoscopic suturing, and thereby accelerate the clinical development of NOTES. Conclusion Incision closure is one of the most challenging tasks in endoscopic surgery such as NOTES. Current mechanical endoscopic suturing devices lack dexterity and suffer numerous functional limitations. While ongoing innovations of better mechanical endoscopic suturing devices are anticipated to fill in some of the unmet demands of reliable, reproducible, and secured suturing in endoscopic surgical applications, the ultimate solution for adequately dextrous, safe and efficient endoscopic suturing could lie in the incorporation of robotics into future suturing systems. 126 IDEN 2014

6 UGS-IV: Emerging but rarely Used Treatment Options in Asia References 1. von Renteln D, Schmidt A, Riecken B, Caca K. Gastric full thickness suturing during EMR and for treatment of gastric wall defects (with video). Gastrointest Endosc 2008;67(4): Chiu PW, Phee SJ, Wang Z, et al. Feasibility of full thickness gastric resection using master and slave transluminal endoscopic robot and closure by Overstitch: a preclinical study. Surg Endosc 2014;28(1): Pauli EM, Delaney CP, Champagne B, Stein S, Marks JM. Safety and effectiveness of an endoscopic suturing device in a human colonic treat and resect model. Surg Innov 2013;20(6): Kantsevoy SV, Bitner M, Mitrakov AA, Thuluvath PJ. Endoscopic suturing closure of large mucosal defects after endoscopic submucosal dissection is technically feasible, fast, and eliminates the need for hospitalization (with videos). Gastrointest Endosc 2014;79(3): Bonin EA, Wong Kee Song LM, Gostout ZS, Bingener J, Gostout CJ. Closure of a persistent esophagopleural fistula assisted by a novel endoscopic suturing system. Endoscopy 2012;44 Suppl 2 UCTN:E Rajan E, Gostout CJ, Aimore Bonin E, et al. Endoscopic full thickness biopsy of the gastric wall with defect closure by using an endoscopic suturing device: survival porcine study. Gastrointest Endosc 2012;76(5): Raju GS, Shibukawa G, Ahmed I, Brining D, et al. Endoluminal suturing may overcome the limitations of clip closure of a gaping wide colon perforation (with videos). Gastrointest Endosc 2007;65(6): Delaney CP, Champagne BJ, Marks JM, Sanuk L, Ermlich B, Chak A. Tissue apposition system: new technology to minimize surgery for endoscopically unresectable colonic polyps. Surg Endosc 2010;24(12): Mellinger JD, MacFadyen BV, Kozarek RA, Soper ND, Birkett DH, Swanstrom LL. Initial experience with a novel endoscopic device allowing intragastric manipulation and plication. Surg Endosc.2007;21(6): Bae, K, Jung, K, Chu, B, et al. Development of a novel successive suturing instrument for an endoscope using beads and a side suction cap. Int. J. Precis. Eng. Manuf 2009;10(2): Song Y, Choi HS, Kim K, et al. A simple novel endoscopic successive suture device: a validation study for closure strength and reproducibility. Endoscopy 2013;45(8): Mori H, Kobara H, Rafiq K, Nishiyama et al. New flexible endoscopic full thickness suturing device: a triple arm bar suturing system. Endoscopy 2013;45(8): Mori H, Kobara H, Fujihara S, et al. Feasibility of pure EFTR using an innovative new endoscopic suturing device: the Doublearm bar Suturing System (with video). Surg Endosc. 2014;28(2): Phee SJ, Ho KY, Lomanto D, Low SC, Huynh VA, Kencana AP, Yang K, Sun ZL, Chung SC. Natural orifice transgastric endoscopic wedge hepatic resection in an experimental model using an intuitively controlled master and slave transluminal endoscopic robot (MASTER). Surg Endosc 2010 Sep;24(9): Epub 2010; Z. Wang, S.J. Phee, D. Lomanto, R. Goel, P. Rebala, Z.L. Sun et al., "Endoscopic submucosal dissection of gastric lesions by using a master and slave transluminal endoscopic robot: an animal survival study," Endoscopy Jul;44(7):690 4, Phee SJ, Reddy N, Chiu PW, et al. Robot assisted endoscopic submucosal dissection is effective in treating patients with earlystage gastric neoplasia. Clin Gastroenterol Hepatol 2012;10(10): IDEN

Intracorporeal Knot-Tying and Suturing Techniques in Laparoscopic Surgery: Technical Details

Intracorporeal Knot-Tying and Suturing Techniques in Laparoscopic Surgery: Technical Details Intracorporeal Knot-Tying and Suturing Techniques in Laparoscopic Surgery: Technical Details E. Croce, MD, S. Olmi, MD ABSTRACT Background: Intracorporeal suturing and knot-tying in laparoscopic surgery

More information

Endoscopic management of common patologies with a new suturing system

Endoscopic management of common patologies with a new suturing system 1130-0108/2014/106/6/413-417 Revista Española de Enfermedades Digestivas Copyright 2014 Arán Ediciones, S. L. Rev Esp Enferm Dig (Madrid Vol. 106, N.º 6, pp. 413-417, 2014 CLINICAL NOTE Endoscopic management

More information

Single balloon Enteroscope system SIF-Q180 / OBCU

Single balloon Enteroscope system SIF-Q180 / OBCU Single Balloon Enteroscope System Single balloon Enteroscope system SIF-Q180 / OBCU There s only one answer to your requirements: the Single Balloon System from Olympus Despite the rapid technological

More information

The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your

The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your 1 The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your treatments more effective but also shorten the time of the

More information

Procedure Guide. Eliminate Big Problems Safely and Quickly Close Your Patients Port Sites

Procedure Guide. Eliminate Big Problems Safely and Quickly Close Your Patients Port Sites NEW! Procedure Guide Eliminate Big Problems Safely and Quickly Close Your Patients Port Sites Following the trocar track helps prevent loss of pneumoperitoneum Ergonomically engineered handle with ribbed

More information

WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS.

WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS. WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS. Endo Stitch Suturing Device Clinically proven technology that can save you time and money 1 6 MAKE YOUR LIFE EASIER. Because that s exactly what our Endo

More information

University of Alabama at Birmingham. ObGyn Residency. Laparoscopy Training Lab PGY 1-4. Individual Pelvic Trainer Tasks

University of Alabama at Birmingham. ObGyn Residency. Laparoscopy Training Lab PGY 1-4. Individual Pelvic Trainer Tasks University of Alabama at Birmingham ObGyn Residency Laparoscopy Training Lab PGY 1-4 Individual Pelvic Trainer Tasks 2010-2011 Skill 1: Peg Board (Blue Board) Goal: Pick up various rings and move them

More information

Techniques of the hand tie and instrument tie

Techniques of the hand tie and instrument tie Techniques of the hand tie and instrument tie 1. The Anatomy of a Square Knot A square knot consists of two "throws". Throws are constructed by crossing the ends of the suture to form a loop and then wrapping

More information

Champion Instrumentation. Shoulder Repair Made Simpler

Champion Instrumentation. Shoulder Repair Made Simpler Champion Instrumentation Shoulder Repair Made Simpler Champion Instruments Simplicity & Versatility The Champion Shoulder instrumentation system was designed with simplicity in mind. Clever instruments

More information

Simple Interrupted Suture (using a tea towel)

Simple Interrupted Suture (using a tea towel) (using a tea towel) Disclaimer A series of booklets has been developed by the Clinical Skills Lab team (staff, recent graduates and students) from the School of Veterinary Sciences, University of Bristol,

More information

Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm

Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm Original Article Yonsei Med J 2017 Jan;58(1):139-143 pissn: 0513-5796 eissn: 1976-2437 Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm Jaehong Woo 1 *, Jae Hyuk

More information

HHS Public Access Author manuscript Gastrointest Endosc Clin N Am. Author manuscript; available in PMC 2016 August 18.

HHS Public Access Author manuscript Gastrointest Endosc Clin N Am. Author manuscript; available in PMC 2016 August 18. Pre-clinical Training for New Notes Procedures: From Ex-vivo Models to Virtual Reality Simulators Mark A. Gromski, MD 1, Woojin Ahn, PhD 2, Kai Matthes, MD, PhD 3, and Suvranu De, ScD 2 1 Division of Gastroenterology/Hepatology,

More information

Methods for Haptic Feedback in Teleoperated Robotic Surgery

Methods for Haptic Feedback in Teleoperated Robotic Surgery Young Group 5 1 Methods for Haptic Feedback in Teleoperated Robotic Surgery Paper Review Jessie Young Group 5: Haptic Interface for Surgical Manipulator System March 12, 2012 Paper Selection: A. M. Okamura.

More information

Suturing simplified. The first and only reusable, articulating, curved needle driver.

Suturing simplified. The first and only reusable, articulating, curved needle driver. Suturing simplified. The first and only reusable, articulating, curved needle driver. Articulating, curved needle precision. An articulating curved needle driver, the Endo360 device is an MIS-enabling

More information

MIS TECHNOLOGY GUIDE READ PRODUCT INSERT THOROUGHLY BEFORE USE

MIS TECHNOLOGY GUIDE READ PRODUCT INSERT THOROUGHLY BEFORE USE COR-KNOT FIG. 1 MIS TECHNOLOGY GUIDE READ PRODUCT INSERT THOROUGHLY BEFORE USE 1 3 COR-KNOT QUICK LOAD UNIT DESCRIPTION Each COR-KNOT QUICK LOAD UNIT provides one sterile COR-KNOT FASTENER 1 held in a

More information

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe Prepared by Genii, Inc. St. Paul, MN, January 2012. (Updated April, 2015) All rights reserved. Introduction

More information

PARS Achilles Jig System

PARS Achilles Jig System PARS Achilles Jig System Surgical Technique PARS Achilles Jig System PARS Achilles Jig System Achilles tendon ruptures are common in the elite and recreational athlete and most often occur in the non-insertional

More information

Simple Interrupted Suture (using a silicon skin pad)

Simple Interrupted Suture (using a silicon skin pad) (using a silicon skin pad) Disclaimer A series of booklets has been developed by the Clinical Skills Lab team (staff, recent graduates and students) from the School of Veterinary Sciences, University of

More information

HOLD FAST WITH EVERY PASS

HOLD FAST WITH EVERY PASS HOLD FAST WITH EVERY PASS ETHICON INTRODUCES NEW STRATAFIX SPIRAL KNOTLESS TISSUE CONTROL DEVICES A comprehensive portfolio for multiple surgical applications. With significantly more points of fixation

More information

Equine Laparoscopy Set by Mariën

Equine Laparoscopy Set by Mariën Equine Laparoscopy Set by Mariën RICHARD WOLF & Veterinary RICHARD WOLF Decades of experience and know-how in veterinary medicine RICHARD WOLF has an almost 100- year history in medical endoscopy. RICHARD

More information

Citation The Journal of surgical research (2.

Citation The Journal of surgical research (2. TitleObtaining secure stapling of a doub Author(s) Nakayama, Shinya; Hasegawa, Kenji; Sakai, Yoshiharu Suguru; Citation The Journal of surgical research (2 Issue Date 2015-02 URL http://hdl.handle.net/2433/193277

More information

PARS Achilles Jig System Surgical Technique

PARS Achilles Jig System Surgical Technique PARS Achilles Jig System Surgical Technique PARS Achilles Jig System PARS Achilles Jig System Achilles tendon ruptures are common in the elite and recreational athlete and most often occur in the noninsertional

More information

Minimally Invasive Suturing Devices

Minimally Invasive Suturing Devices Instructions for Use Minimally Invasive Suturing Devices MODELS COVERED ECDL-01 Standard Laparoscopic Length 374 mm ECDS-01 Shorter Length for Urogynecology 222 mm and other natural orifice applications

More information

Arthroscopic Protector Meniscus Suturing Surgical Techniques

Arthroscopic Protector Meniscus Suturing Surgical Techniques Arthroscopic Protector Meniscus Suturing Surgical Techniques Protector Meniscus Suturing Protector Meniscus Suturing Technique I For the relatively rare meniscus tears located sufficiently anterior, to

More information

Product Pamphlet. Parcus Medical s Value Proposition Program is designed to reduce cost per case by:

Product Pamphlet. Parcus Medical s Value Proposition Program is designed to reduce cost per case by: Product Pamphlet Parcus Medical designs, manufactures, and distributes implants and instrumentation used by orthopedic surgeons in sports medicine procedures to repair the shoulder, knee, hip, and distal

More information

Rotator Cuff Repair ICONN Answer PEEK Suture Anchor 4.75/5.5. Surgical Protocol by Geoffrey Connor, 4.75/5.5 MD of D1 Sports Medicine

Rotator Cuff Repair ICONN Answer PEEK Suture Anchor 4.75/5.5. Surgical Protocol by Geoffrey Connor, 4.75/5.5 MD of D1 Sports Medicine Rotator Cuff Repair ICONN Answer PEEK Suture Anchor 4.75/5.5 Surgical Protocol by Geoffrey Connor, 4.75/5.5 MD of D1 Sports Medicine ICONN s revolutionary approach is to drive value into every aspect of

More information

WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS.

WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS. WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS. Endo Stitch Suturing Device Clinically proven technology that s designed to make suturing easier, faster, and save you money. 1 6 Just a few of the reasons

More information

ARTHROSCOPIC ROTATOR CUFF REPAIR SURGICAL TECHNIQUE. The following techniques are described by Vernon J. Cooley, M.D.

ARTHROSCOPIC ROTATOR CUFF REPAIR SURGICAL TECHNIQUE. The following techniques are described by Vernon J. Cooley, M.D. The UltraSorb Rotator Cuff Suture Anchor offers superior performance, reliability, and reproducibility for mini-open or arthroscopic repairs. The Poly-L-Lactide Acid (PLLA) UltraSorb Implant is pre-loaded

More information

Tianjin Onehealth Medical Instruments. Onehealth Your surgical solutions partner

Tianjin Onehealth Medical Instruments. Onehealth Your surgical solutions partner Tianjin Onehealth Medical Instruments Introduction Tianjin Onehealth Medical Instruments Co Ltd is a part of KXBD Group which was established in 2006. Onehealth has a long term and massive investment strategy

More information

1 May Telesurgery with haptic sensation: The future of surgery. Michael Stark The New European Surgical Academy (NESA)

1 May Telesurgery with haptic sensation: The future of surgery. Michael Stark The New European Surgical Academy (NESA) 1 May 2014 Telesurgery with haptic sensation: The future of surgery Michael Stark The New European Surgical Academy (NESA) Disclosure Michael Stark is the scientific advisor for the EU/SOFAR European Telesurgical

More information

Objectives. xxx00.#####.ppt 5/10/17 9:42 AM

Objectives. xxx00.#####.ppt 5/10/17 9:42 AM Objectives Understand and demonstrate proper suturing techniques Learn how to properly handle instruments Know types of suture and appropriate use Hand-tying Learn how to trouble-shoot complications after

More information

Using Simulation to Design Control Strategies for Robotic No-Scar Surgery

Using Simulation to Design Control Strategies for Robotic No-Scar Surgery Using Simulation to Design Control Strategies for Robotic No-Scar Surgery Antonio DE DONNO 1, Florent NAGEOTTE, Philippe ZANNE, Laurent GOFFIN and Michel de MATHELIN LSIIT, University of Strasbourg/CNRS,

More information

PATENT SPECIFICATION SYSTEM E FÜR M INIM AL INVASIVE G ASTR O IN TESTINALE VERFAHREN

PATENT SPECIFICATION SYSTEM E FÜR M INIM AL INVASIVE G ASTR O IN TESTINALE VERFAHREN ( 19) Europäisches Patentamt (12) European Patent Office Office européen des brevets EUROPEAN PATENT SPECIFICATION (11) EP 1 962 700 B1 (45) (21) (22) Date of publication and mention of the grant of the

More information

LabraLock P for Labrum Repair, LabraFix System. The Reinforcement Technique Guide

LabraLock P for Labrum Repair, LabraFix System. The Reinforcement Technique Guide LabraLock P for Labrum Repair, Part of the OPUS LabraFix System A revolutionary new system specifically designed for labrum repair surgery System Includes: SpeedStitch Suturing Device LabraLock P Implant

More information

Endoscopic Ultrasonography System

Endoscopic Ultrasonography System Endoscopic Ultrasonic Processor SU- -H-, SU- -S- Power rating Power supply rating Current consumption(rated) Dimensions Size Weight Ultrasonography Probe types image display Scanning modes Special modes*

More information

Small Occupancy Robotic Mechanisms for Endoscopic Surgery

Small Occupancy Robotic Mechanisms for Endoscopic Surgery Small Occupancy Robotic Mechanisms for Endoscopic Surgery Yuki Kobayashi, Shingo Chiyoda, Kouichi Watabe, Masafumi Okada, and Yoshihiko Nakamura Department of Mechano-Informatics, The University of Tokyo,

More information

Surgical Education Arrow project meeting

Surgical Education Arrow project meeting Surgical Education Arrow project meeting 5.1.18 Dr. Imri Amiel M.D MSR, the Israel Center for Medical Simulation Department of General Surgery B, The Chaim Sheba Medical Center The Talpiot Medical Leadership

More information

ENDOSCOPIC ULTRASOUND SYSTEMS

ENDOSCOPIC ULTRASOUND SYSTEMS ENDOSCOPIC ULTRASOUND SYSTEMS DISCOVER HIGH-PRECISION DIAGNOSES AND PROCEDURES NEW ENDOSCOPIC ULTRASOUND Ultrasonography revolutionized the clinical approach to patients with digestive and respiratory

More information

Introducing the LumiCoil Platinum Fiducial Marker. Features of LumiCoil Platinum Fiducial Markers. Expanding Innovation in EUS

Introducing the LumiCoil Platinum Fiducial Marker. Features of LumiCoil Platinum Fiducial Markers. Expanding Innovation in EUS LumiCoil Platinum Introducing the LumiCoil Platinum Features of LumiCoil Platinum s Expanding Innovation in EUS Ordering Information and Additional Resources LumiCoil Platinum Introducing the LumiCoil

More information

Maneuverability Evaluation of a Surgical Robot for Single-Port Surgery

Maneuverability Evaluation of a Surgical Robot for Single-Port Surgery International Journal of Pharma Medicine and Biological Sciences Vol. 5, No. 1, January 2016 Maneuverability Evaluation of a Surgical Robot for Single-Port Surgery Katsuaki Oiwa, Shotaro Maeda, and Chiharu

More information

RAISING THE LEVEL OF PROTECTION IN YOUR ORS

RAISING THE LEVEL OF PROTECTION IN YOUR ORS Outpatient Supplement to www outpatientsurgery.net Surgery R October 2009 Magazine 2009-10 Manager s Guide to Patient Safety RAISING THE LEVEL OF PROTECTION IN YOUR ORS E L E C T R O S U R G E R Y S A

More information

Suture patterns. If you would like to submit an article for publication contact the editorial panel at

Suture patterns. If you would like to submit an article for publication contact the editorial panel at Suture patterns Thomas Sissener MS DVM MRCVS RESIDENT IN SMALL ANIMAL SURGERY, THE QUEEN S VETERINARY SCHOOL HOSPITAL, DEPARTMENT OF VETERINARY MEDICINE, UNIVERSITY OF CAMBRIDGE, MADINGLEY ROAD, CAMBRIDGE.

More information

Dr. S.D. Gerber Double Row Method Surgical Technique

Dr. S.D. Gerber Double Row Method Surgical Technique Dr. S.D. Gerber Double Row Method Surgical Technique Dr. S.D. Gerber Double Row Method Surgical Technique Introduction There has been a rapid proliferation of techniques for arthroscopic rotator cuff tear

More information

Autonomous Surgical Robotics

Autonomous Surgical Robotics Nicolás Pérez de Olaguer Santamaría Autonomous Surgical Robotics 1 / 29 MIN Faculty Department of Informatics Autonomous Surgical Robotics Nicolás Pérez de Olaguer Santamaría University of Hamburg Faculty

More information

Cerclage Passer. For minimally invasive application of cerclage cables.

Cerclage Passer. For minimally invasive application of cerclage cables. Cerclage Passer. For minimally invasive application of cerclage cables. Handling Technique Cable application This publication is not intended for distribution in the USA. Instruments and implants approved

More information

ERCP Papillotomes, balloons, guide wires and baskets.

ERCP Papillotomes, balloons, guide wires and baskets. Papillotomes, balloons, guide wires and baskets. REF Lumens Tip length mm Working length mm Cutting wire length mm Partly insulated cutting wire Papillotome DSP-30525-111111 3 5 2000 25 no DSP-30225-111111

More information

Advancing the Art of Endoscopy

Advancing the Art of Endoscopy Advancing the Art of Endoscopy Advancing the Art of Endoscopy with an array of opto-digital innovations. OLYMPUS technology continues to advance the art of endoscopy. As the world leader in endoscopy,

More information

Prostar XL Percutaneous Vascular Surgical Device

Prostar XL Percutaneous Vascular Surgical Device Clinical leader for percutaneous large access site closure Close Access Sites Up to 24F Secure Closure Prostar XL Percutaneous Vascular Surgical Device Improved Outcomes 2009 Abbott Laboratories. All rights

More information

EXpERIENCE THE power Of LIGHT

EXpERIENCE THE power Of LIGHT EXpERIENCE THE power Of LIGHT GASTROENTEROLOGY MAKING YOUR DAILY WORK EaSIER ENDOSCOpES processors preparation & HYGIENICS ULTRa- SONOGRapHY ENDOSCOpY SYSTEM fujifilm is a pioneer in diagnostic imaging

More information

Chapter 1. Introduction

Chapter 1. Introduction Chapter 1 Introduction Robotics technology has recently found extensive use in surgical and therapeutic procedures. The purpose of this chapter is to give an overview of the robotic tools which may be

More information

Medical Robotics. Part II: SURGICAL ROBOTICS

Medical Robotics. Part II: SURGICAL ROBOTICS 5 Medical Robotics Part II: SURGICAL ROBOTICS In the last decade, surgery and robotics have reached a maturity that has allowed them to be safely assimilated to create a new kind of operating room. This

More information

SMart wearable Robotic Teleoperated surgery

SMart wearable Robotic Teleoperated surgery SMart wearable Robotic Teleoperated surgery This project has received funding from the European Union s Horizon 2020 research and innovation programme under grant agreement No 732515 Context Minimally

More information

Magnified Examination of Small Colorectal Polyps Using a Prototype Electronic Endoscope: Preliminary Experience

Magnified Examination of Small Colorectal Polyps Using a Prototype Electronic Endoscope: Preliminary Experience Diagnostic and Therapeutic Endoscopy, Vol. 6, pp. 77-82 Reprints available directly from the publisher Photocopying permitted by license only (C) 2000 OPA (Overseas Publishers Association) N.V. Published

More information

Advancing the Art of Endoscopy

Advancing the Art of Endoscopy Advancing the Art of Endoscopy Advancing the Art of Endoscopy with an array of opto-digital innovations. OLYMPUS technology continues to advance the art of endoscopy. As the world leader in endoscopy,

More information

PUSH-PULL-PROPS. and accessories ROBUSTA-GAUKEL GMBH MOUNTING TECHNOLOGY &CO.KG

PUSH-PULL-PROPS. and accessories ROBUSTA-GAUKEL GMBH MOUNTING TECHNOLOGY &CO.KG PUSH-PULL-PROPS and accessories MOUNTING TECHNOLOGY ROBUSTA-GAUKEL GMBH &CO.KG MOUNTING TECHNOLOGY PUSH-PULL-PROPS AND ACCESSORIES INDEX General information...................... 3 Push-pull-prop Type

More information

Designed to improve physician productivity and patient care.

Designed to improve physician productivity and patient care. Designed to improve physician productivity and patient care. Fujinon s most advanced Video Bronchoscopes are designed for physician productivity and patient care. Advanced miniature chip technology sets

More information

Dental Sutures. Japanese quality for best results.

Dental Sutures. Japanese quality for best results. Dental Sutures Japanese quality for best results. / Standard stainless steel vs. MANI hard-fiber stainless steel 1 mm MANI hard-fiber stainless steel The original fine technology of processing offers you

More information

A New Needle Holder Facilitating Palm Grip Suturing

A New Needle Holder Facilitating Palm Grip Suturing Received: June 3, 2014 Accepted after revision: August 26, 2014 Published online: October 24, 2014 0014 312X/14/0542 0055$39.50/0 Original Paper A New Needle Holder Facilitating Palm Grip Suturing Carl-Fredrik

More information

Suture anchors for VeterinarY use

Suture anchors for VeterinarY use Suture anchors for VeterinarY use For Joint Stabilization and Ligamentous and Tendon Injury Repairs in Cats and Dogs Mini QUICKANCHOR Plus Anchor GII QUICKANCHOR Plus Anchor Super QUICKANCHOR Plus Dual

More information

Surgeon-Tool Force/Torque Signatures - Evaluation of Surgical Skills in Minimally Invasive Surgery

Surgeon-Tool Force/Torque Signatures - Evaluation of Surgical Skills in Minimally Invasive Surgery # J. Rosen et al. Surgeon-Tool Force/Torque Signatures Surgeon-Tool Force/Torque Signatures - Evaluation of Surgical Skills in Minimally Invasive Surgery Jacob Rosen +, Ph.D., Mark MacFarlane *, M.D.,

More information

Cost savings without compromise

Cost savings without compromise Cost savings without compromise Why VPL Sutures? Reduce your cost, not your quality. With over 20 years in the U.S. veterinary channel and building on the tradition of the over 100 year B. Braun legacy,

More information

Cooperative Robotic Assistant for Laparoscopic Surgery: CoBRASurge

Cooperative Robotic Assistant for Laparoscopic Surgery: CoBRASurge The 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems October 11-15, 2009 St. Louis, USA Cooperative Robotic Assistant for Laparoscopic Surgery: CoBRASurge Xiaoli Zhang, Amy Lehman,

More information

A free-extending two part cannulated screw that will elongate with growth. SURGICAL TECHNIQUE

A free-extending two part cannulated screw that will elongate with growth. SURGICAL TECHNIQUE A free-extending two part cannulated screw that will elongate with growth. SURGICAL TECHNIQUE The Free-Gliding SCFE Screw System, designed to treat the most common hip problem in growing children, SLIPPED

More information

Fundamental 7echniques Veterinary

Fundamental 7echniques Veterinary Fundamental 7echniques Veterinary urger~_ THIRD EDITION CHARLES D. KNECHl: B.S., \l.m.d., M.S. Diplomate, American College of Veterinary Surgeons Diplomate, American College of Veterinary Internal Medicine

More information

Super Revo. Surgical Technique. Super Revo Shoulder Fixation System. The Ideal Fixation Device For Rotator Cuff Repair. Self-drilling, titanium anchor

Super Revo. Surgical Technique. Super Revo Shoulder Fixation System. The Ideal Fixation Device For Rotator Cuff Repair. Self-drilling, titanium anchor Super Revo Shoulder Fixation System The Ideal Fixation Device For Rotator Cuff Repair Super Revo Surgical Technique INCREASED Strength and Suture Management Self-drilling, titanium anchor Independent Suture

More information

Ethicon Open Stapling A solution for every staple line

Ethicon Open Stapling A solution for every staple line Ethicon Open Stapling A solution for every staple line Open Right Colectomy 1. Use the PROXIMATE Linear Cutter (TLC) to to transect the proximal and distal ends of the specimen 2. Perform a side to side

More information

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair. Technique Guide Modular Sternal Cable System. Flexibility and strength in sternal closure and repair. Table of Contents Introduction Overview 2 Indications and Contraindications 3 Surgical Technique A.

More information

Tyler Alignment & Calibration System For the Leksell Stereotactic Frame

Tyler Alignment & Calibration System For the Leksell Stereotactic Frame Tyler Alignment & Calibration System For the Leksell Stereotactic Frame Instructions for Use TYLER Research Corporation BIOMEDICAL ENGINEERING CANADA Rev 1.3 14.06.2018 Leksell Stereotactic Neurosurgery

More information

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D. Double Row Rotator Cuff Repair Surgical Protocol by Frank Bonnarens, M.D. This brochure is presented to demonstrate the surgical technique utilized by Frank Bonnarens, M.D. Biomet Sports Medicine, as the

More information

Wide range in small dimensions

Wide range in small dimensions Wide range in small dimensions The complete solution for Minilaparoscopy The complete solution for Minilaparoscopy The use of 3.5 mm instruments and appropriate trocars leaves behind only very small scars

More information

GET MORE. WITH LESS. Less sticking. 1, Less cleaning. 2, Less eschar buildup. 2, More benefits. LigaSure Maryland jaw device with nano-coated jaws

GET MORE. WITH LESS. Less sticking. 1, Less cleaning. 2, Less eschar buildup. 2, More benefits. LigaSure Maryland jaw device with nano-coated jaws GET MORE. WITH LESS. Less sticking. 1, Less cleaning. 2, Less eschar buildup. 2, More benefits. LigaSure Maryland jaw device with nano-coated jaws Instances of tissue sticking to jaws measured over 110

More information

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D. Double Row Rotator Cuff Repair Surgical Protocol by Frank Bonnarens, M.D. Features Lateral row knotless anchor fixation Lower knot profile medially and completely knotless laterally No arthroscopic knot

More information

Haptic Feedback in Laparoscopic and Robotic Surgery

Haptic Feedback in Laparoscopic and Robotic Surgery Haptic Feedback in Laparoscopic and Robotic Surgery Dr. Warren Grundfest Professor Bioengineering, Electrical Engineering & Surgery UCLA, Los Angeles, California Acknowledgment This Presentation & Research

More information

Application of Force Feedback in Robot Assisted Minimally Invasive Surgery

Application of Force Feedback in Robot Assisted Minimally Invasive Surgery Application of Force Feedback in Robot Assisted Minimally Invasive Surgery István Nagy, Hermann Mayer, and Alois Knoll Technische Universität München, 85748 Garching, Germany, {nagy mayerh knoll}@in.tum.de,

More information

VERSALOK. Suture Anchor. Rotator Cuff Repair Surgical Technique

VERSALOK. Suture Anchor. Rotator Cuff Repair Surgical Technique VERSALOK Suture Anchor Rotator Cuff Repair Surgical Technique Introduction VERSALOK Suture Anchor, available in Titanium and PEEK from DePuy Synthes Mitek Sports Medicine, were designed to allow for versatile

More information

Wearable Haptic Feedback Actuators for Training in Robotic Surgery

Wearable Haptic Feedback Actuators for Training in Robotic Surgery Wearable Haptic Feedback Actuators for Training in Robotic Surgery NSF Summer Undergraduate Fellowship in Sensor Technologies Joshua Fernandez (Mechanical Eng.) University of Maryland Baltimore County

More information

Right Angle Screwdriver

Right Angle Screwdriver Right Angle Screwdriver October 12, 2009 Team: Scott Carpenter - Team Leader Chuck Donaldson - Communicator Nate Retzlaff - BWIG John McGuire - BSAC Client: Ashish Mahajan, MD Resident Plastic and Reconstructive

More information

Surgical robot simulation with BBZ console

Surgical robot simulation with BBZ console Review Article on Thoracic Surgery Surgical robot simulation with BBZ console Francesco Bovo 1, Giacomo De Rossi 2, Francesco Visentin 2,3 1 BBZ srl, Verona, Italy; 2 Department of Computer Science, Università

More information

Ethicon Open Stapling A solution for every staple line

Ethicon Open Stapling A solution for every staple line Ethicon Open Stapling A solution for every staple line Open Right Colectomy 1. Use the PROXIMATE Linear Cutter to transect the proximal and distal ends of the specimen 2. Perform a side to side anastomosis

More information

ENDOSCOPIC ULTRASOUND SYSTEMS

ENDOSCOPIC ULTRASOUND SYSTEMS ENDOSCOPIC ULTRASOUND SYSTEMS DISCOVER HIGH-PRECISION DIAGNOSES AND PROCEDURES NEW ENDOSCOPIC ULTRASOUND Ultrasonography revolutionized the clinical approach to patients with digestive and respiratory

More information

Knotless SutureTak Instability Repair. Surgical Technique

Knotless SutureTak Instability Repair. Surgical Technique Knotless SutureTak Instability Repair Surgical Technique Knotless SutureTak Instability Repair Load-to-Failure (lbf) Knotless SutureTak Instability Repair The Knotless SutureTak suture anchor simplifies

More information

5th Metatarsal Fracture System Surgical Technique

5th Metatarsal Fracture System Surgical Technique 5th Metatarsal Fracture System Surgical Technique 5th Metatarsal Fracture System 5th Metatarsal Fracture System The 5th Metatarsal Fracture System (AR-8956S) is a uniquely designed screw and plate system

More information

Measurements of the Level of Surgical Expertise Using Flight Path Analysis from da Vinci Robotic Surgical System

Measurements of the Level of Surgical Expertise Using Flight Path Analysis from da Vinci Robotic Surgical System Measurements of the Level of Surgical Expertise Using Flight Path Analysis from da Vinci Robotic Surgical System Lawton Verner 1, Dmitry Oleynikov, MD 1, Stephen Holtmann 1, Hani Haider, Ph D 1, Leonid

More information

Towards robotic heart surgery: Introduction of autonomous procedures into an experimental surgical telemanipulator system

Towards robotic heart surgery: Introduction of autonomous procedures into an experimental surgical telemanipulator system 74 ORIGINAL ARTICLE Towards robotic heart surgery: Introduction of autonomous procedures into an experimental surgical telemanipulator system R Bauernschmitt*, E U Schirmbeck*, A Knoll, H Mayer, I Nagy,

More information

Superb Model Over 1,000 Stitch Functions

Superb Model Over 1,000 Stitch Functions Over 1,000 Stitch Functions Select from over 1,000 Stitch Functions. Fulfill your creative dreams with a large selection of decorative stitches, alphabet stitches, and construction stitches. Large Back-Lit

More information

Haptic Feedback in Robot Assisted Minimal Invasive Surgery

Haptic Feedback in Robot Assisted Minimal Invasive Surgery K. Bhatia Haptic Feedback in Robot Assisted Minimal Invasive Surgery 1 / 33 MIN Faculty Department of Informatics Haptic Feedback in Robot Assisted Minimal Invasive Surgery Kavish Bhatia University of

More information

Digital Compression Screw

Digital Compression Screw Digital Compression Screw Surgical Technique Contents Product The BioPro Digital Compression Screw is a stainless steel lag screw designed for digital fusions. Table of contents Indications & Contraindications

More information

The New Dimension in Imaging

The New Dimension in Imaging URO 46 4.0 06/2018-E The New Dimension in Imaging Flexible Video Uretero-Renoscope with enhanced imaging options The New Dimension in Imaging When imaging meets the greatest challenges KARL STORZ, as a

More information

Takeshi Omori, Jeong-Ho Moon, Kazuyoshi Yamamoto, Yoshitomo Yanagimoto, Keijirou Sugimura, Hiroshi Miyata, Masahiko Yano, Masato Sakon

Takeshi Omori, Jeong-Ho Moon, Kazuyoshi Yamamoto, Yoshitomo Yanagimoto, Keijirou Sugimura, Hiroshi Miyata, Masahiko Yano, Masato Sakon Review rticle modified efficient purse-string stapling technique (mest) that uses a new metal rod for intracorporeal esophagojejunostomy in laparoscopic total gastrectomy Takeshi Omori, Jeong-Ho Moon,

More information

The OPUS AutoCuff System for Rotator Cuff Repair

The OPUS AutoCuff System for Rotator Cuff Repair The OPUS AutoCuff System for Rotator Cuff Repair A revolutionary new system specifically designed for rotator cuff repair surgery System Includes: SmartStitch Suturing Device The Magnum PI Implant with

More information

The Perfect Close. to your surgical procedure. PER F ORM ANC E through innovation

The Perfect Close. to your surgical procedure. PER F ORM ANC E through innovation The Perfect Close to your surgical procedure PER F ORM ANC E through innovation GORE-TEX Suture is a unique, microporous, nonabsorbable monofilament made of expanded polytetrafluoroethylene (eptfe), the

More information

A Single-Port Robotic System for Transanal Micro-Surgery Design and Validation

A Single-Port Robotic System for Transanal Micro-Surgery Design and Validation IEEE ROBOTICS AND AUTOMATION LETTERS. PREPRINT VERSION. ACCEPTED JANUARY, 2017 1 A Single-Port Robotic System for Transanal Micro-Surgery Design and Validation Jianzhong Shang 1, Konrad Leibrandt 1, Petros

More information

The information contained in this document is intended for healthcare professionals only.

The information contained in this document is intended for healthcare professionals only. The information contained in this document is intended for healthcare professionals only. Apex Pin Fixation System Half Pins, Transfixing Pins & Instruments 1 Table of Contents Introduction.......................................................................01

More information

Integra. Capture Screw System SURGICAL TECHNIQUE

Integra. Capture Screw System SURGICAL TECHNIQUE Integra Capture Screw System SURGICAL TECHNIQUE Table of Contents Indications... 2 Contraindications... 2 System Description... 2 System Features... 2 Cannulated Low-Profile Screws (AC-Series) Overview...

More information

Ayuekanbe Atagabe. Physics 464(applied Optics) Winter Project Report. Fiber Optics in Medicine. March 11, 2003

Ayuekanbe Atagabe. Physics 464(applied Optics) Winter Project Report. Fiber Optics in Medicine. March 11, 2003 Ayuekanbe Atagabe Physics 464(applied Optics) Winter 2003 Project Report Fiber Optics in Medicine March 11, 2003 Abstract: Fiber optics have become very important in medical diagnoses in this modern era

More information

OPHTHALMIC SURGICAL MODELS

OPHTHALMIC SURGICAL MODELS OPHTHALMIC SURGICAL MODELS BIONIKO designs innovative surgical models, task trainers and teaching tools for the ophthalmic industry. Our surgical models present the user with dexterity and coordination

More information

Robots in the Field of Medicine

Robots in the Field of Medicine Robots in the Field of Medicine Austin Gillis and Peter Demirdjian Malden Catholic High School 1 Pioneers Robots in the Field of Medicine The use of robots in medicine is where it is today because of four

More information

Evaluation of robotically controlled advanced endoscopic instruments

Evaluation of robotically controlled advanced endoscopic instruments THE INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY Int J Med Robotics Comput Assist Surg 2013; 9: 240 246. Published online 23 April 2013 in Wiley Online Library (wileyonlinelibrary.com).1496

More information

Suturing simplified. The first and only reusable, articulating, curved needle driver.

Suturing simplified. The first and only reusable, articulating, curved needle driver. Suturing simplified. The first and only reusable, articulating, curved needle driver. Articulating, An articulating curved needle driver, the Endo360 device is an MIS-enabling tool that allows the placement

More information

HUMAN Robot Cooperation Techniques in Surgery

HUMAN Robot Cooperation Techniques in Surgery HUMAN Robot Cooperation Techniques in Surgery Alícia Casals Institute for Bioengineering of Catalonia (IBEC), Universitat Politècnica de Catalunya (UPC), Barcelona, Spain alicia.casals@upc.edu Keywords:

More information