Recital_sound Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage.

Size: px
Start display at page:

Download "Recital_sound Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage."

Transcription

1 Recital_sound 18-1

2 Recital_sound 18 : The Equipment 18 1 Control Room Equipment 18- Item Brand/Type Amount Notes Mixer EUPHONIX SYSTEM5B 1 4 ANNEL 16AUX 4GROUP 4 MASTER CD Player TASCAM-CD 01UPRO 1 For performance audio playback, recording use, CD-RW TASCAM CD-RW000 Monitor Speaker GENELEC 8050A Wireless Microphone / Mini Microphone SHURE ULXP4 18 Speaker System Main Speaker (HANDHELD) (LAVALIER) recording fee please see Venue Rental Handbook. Extra rental fee required. Please see Venue Rental Handbook. Item Brand/Type Amount Position Notes MEYER SOUND Both sides UPM-1P of stage Microphone Circuit 18 3 Microphone 18 Three sides of the wall. active speaker L/R can be outputted by Left/ Right Track. See Appendix 3-5 for details. Brand Type Amount Note NEUMANN U87AI 4 Condenser NEUMANN KM Condenser AKG D330BT 10 Dynamic AKG C Condenser AKG C56BL 3 Condenser AKG D11 4 Dynamic AKG C414B-XLS 8 Condenser SHURE SM57 10 Dynamic SHURE SM58 10 Dynamic SHURE BA 57A 6 Dynamic SHURE BA 58A 5 Dynamic SHURE BA 91 Dynamic For Jazz drum set SHURE PGDMK6-XLR 1set SENNHEISER MD-441U 1 Dynamic SENNHEISER MKH-70 6 Condenser SHOTGUN Supply to the National Theatre, Concert Hall, Experimental Theatre and Recital Hall, the rental fee please see Venue Rental Handbook CROWN PCC Condenser SOEPS CMC6+MK4g Condenser 18 4 Microphone Stand Item Factory /Type Amount Note AKG ST cm extension arm AKG ST cm extension arm PHILIPS T 10

3 Recital_sound 18 5 Microphone Circuit Chart 18 6 Intercom System Main Station Item Brand/Type Amount Position Notes Clear-Com MS - Clear-Com sub-station KB - 111A 4 Portable station RS - 100A Intercom Headset CC-75 Calling & Paging substation KB - 111A 1 Control room Stand by area channels with one ear phone connected 18-3

4 18 7 Intercom System Position Chart Recital_sound 19-1

5 Recital_ 19 : System 19 1 Control Room Item Brand/ Type Amount Note HD Camera Set Camera power supply IKEGAMI BS-89 IKEGAMI HDK-79EX Ⅲ 1 OCP Station on the center of 3rd floor balcony. Single camera operation 3. HD / SD-SDI & Composite output 4. For house program archives performing groups monitoring, and late comers viewing in the lobby Frequency Monitor PROTE HDF Pioneer DVR-630H Provide program video Pioneer DVR-LX70 1 recording service, the DVR Recorder service rate please see Pioneer DVR the Venue Rental Handbook Color monitor 9" HDTV HLM-904WR 3 Color Monitor 17 HDTV HLM-1704WR 1 RF Converter WINERSAT WAM-860SL Convert the video image signal to RF signal for both back stage & FOH TV monitors..7:stage area.8:foh area 19 Monitor System(MATV) Area Brand/Type Amount Note BF FOH Lobby 4" LED TV BF right stand by area SAMPO 0" TV 1 For performing groups BF left stand by area 4" LED TV 1 monitoring, and late comers viewing in the BF Manager desk IMEI 0 LCD 1 lobby. GF Control room SAMPO 0 LCD 1 19-

6 Recital_ 19 3 LED Subtitle Machine,Projector,Projection Item Factory/ Type Amount Note LED Subtitle Machine 16 words 6000 ANSI lumen (Lens : :1, 1.3- Panasonic PT-D5700U 3 1.8:1) 500 ANSI lumen EPSON ANSI lumen EPSON EMP-7800UG 3000 ANSI lumen SONY VPL-SX Front Projection 100 Front Projection 100 Rear Projection DA-LITE SP-80 Pneumatic cylinders 180 cm *135 cm DA-LITE SP-100 Pneumatic cylinders 14cm *163 cm The Works E-Z Folding Gray color 14 cm *163 cm 4 4 Supply to the National Theatre, Concert Hall, Experimental Theatre and Recital Hall, the rental fee please see Venue Rental Handbook 150 Front and Rear Projection DA-LITE / Folding 305 cm*9 cm 10 Front and Rear Projection DA-LITE / Folding 47 cm *30 cm Notebook Computer Factory Type Amount Note ASUS A8S ASUS A8Ja ASUS X450J Supply to the National Theatre, Concert Hall, Experimental Theatre and Recital Hall, the rental fee please see Venue Rental Handbook. The computer is for projecting performance images & information use only 19-3

7 Recital_ 19 3 LED Subtitle Machine,Projector,Projection Item Factory/ Type Amount Note LED Subtitle Machine 16 words 6000 ANSI lumen (Lens : :1, 1.3- Panasonic PT-D5700U 3 1.8:1) 500 ANSI lumen EPSON ANSI lumen EPSON EMP-7800UG 3000 ANSI lumen SONY VPL-SX Front Projection 100 Front Projection 100 Rear Projection DA-LITE SP-80 Pneumatic cylinders 180 cm *135 cm DA-LITE SP-100 Pneumatic cylinders 14cm *163 cm The Works E-Z Folding Gray color 14 cm *163 cm 4 4 Supply to the National Theatre, Concert Hall, Experimental Theatre and Recital Hall, the rental fee please see Venue Rental Handbook 150 Front and Rear Projection DA-LITE / Folding 305 cm*9 cm 10 Front and Rear Projection DA-LITE / Folding 47 cm *30 cm Notebook Computer Factory Type Amount Note ASUS A8S ASUS A8Ja ASUS X450J Supply to the National Theatre, Concert Hall, Experimental Theatre and Recital Hall, the rental fee please see Venue Rental Handbook. The computer is for projecting performance images & information use only 19-4

8 Recital_ 19-5

Concert Hall_sound Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage.

Concert Hall_sound Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage. 3- 3 : The Equipment 3 Control Room Item Brand/Type Amount Note Mixer STUDER VISTA- 8 40 Channel 0 Line Channel 8 Master mono 8 Group stereo 0 Aux mono 4 Aux Stereo CD player TASCAM CD-450 For performance

More information

Equipment List by Room

Equipment List by Room MESSIAH COLLEGE HIGH CENTER FOR THE PERFORMING ARTS March 19, 2014 Major Components Qty Parmer Hall 1 FOH Console Digidesign Venue SC48-Remote 1 2 Main Hall Processing BSS BLU-800 1 3 Main Hall Processing

More information

Jockey Club Auditorium - Technical Information

Jockey Club Auditorium - Technical Information Jockey Club Auditorium - Technical Information General Set-up Jockey Club Auditorium operates on a bare-walls touring policy. That is, all equipment is normally setup and struck within the booking period.

More information

St Pancras Room Technical Specification

St Pancras Room Technical Specification St Pancras Room Technical Specification Details shown are correct as of January 2012 Subject to change. Kings Place Music Foundation 90 York Way, London N1 9AG www.kingsplace.co.uk St Pancras Room 2.1

More information

Duncan Theatre Technical Specifications 6/16. Contact: Josh Schneider, Technical Director, , FAX

Duncan Theatre Technical Specifications 6/16. Contact: Josh Schneider, Technical Director, , FAX AT PALM BEACH STATE COLLEGE 4200 Congress Avenue, MS 62 Lake Worth, FL 33461 Josh Schneider, Technical Director 561-868-3313, Fax 561-868-3317 schneidj@palmbeachstate.edu Duncan Theatre Technical Specifications

More information

Jockey Club Auditorium - Technical Information

Jockey Club Auditorium - Technical Information Jockey Club Auditorium - Technical Information General Set-up Jockey Club Auditorium operates on a bare-walls touring policy. That is, all equipment is normally set-up and struck within the booking period.

More information

For more information please contact Bob Luffman at Ext or by at

For more information please contact Bob Luffman at Ext or by  at SOUND INFORMATION For more information please contact Bob Luffman at 519.578.5660 Ext. 5235 or by email at bluffman@centreinthesquare.com INDEX MAIN SOUND SYSTEM Page 1 CENTER CLUSTER 1 ON-STAGE SOUND

More information

Front-Of-House mixing desks: Monitor mixing desk: House speakers (main stacks): Allen & Heath GL4000. Allen & Heath GL4

Front-Of-House mixing desks: Monitor mixing desk: House speakers (main stacks): Allen & Heath GL4000. Allen & Heath GL4 COMFAC Concert Sound Equiipment Liist Front-Of-House mixing desks: Allen & Heath GL4000-40 channel (40x8xx1), 4-band full sweep equalizers with selectable Q mids - sweepable lo-cut filters / phase reverse

More information

TECHNICAL RIDER SALA BARTS BARCELONA ARTS ON STAGE. BARTS is a venue located at Barcelona city centre where most important theatres are.

TECHNICAL RIDER SALA BARTS BARCELONA ARTS ON STAGE. BARTS is a venue located at Barcelona city centre where most important theatres are. TECHNICAL RIDER SALA BARTS BARCELONA ARTS ON STAGE BARTS is a venue located at Barcelona city centre where most important theatres are. BARTS Avda. Paral.lel, 62 08001 BARCELONA http://www.barts.cat STAGE

More information

RiverCenter for the Performing Arts. House Sound System

RiverCenter for the Performing Arts. House Sound System RiverCenter for the Performing Arts House Sound System PLEASE NOTE THAT THE ENTIRE INVENTORY MAY NOT BE AVAILABLE FOR YOUR PRODUCTION. PLEASE CONFIRM INVENTORY WITH THE TECHNICAL DIRECTOR AT LEAST 30 DAYS

More information

AUDIO INVENTORY. Available as Front Fill Speakers Positioned evenly across the DS edge of stage 2 D&B V7P Speakers Available as Outer Fill Speakers

AUDIO INVENTORY. Available as Front Fill Speakers Positioned evenly across the DS edge of stage 2 D&B V7P Speakers Available as Outer Fill Speakers PAGE 50 OF 86 AUDIO INVENTORY SOUND SYSTEM INVENTORY QUANTITY MAKE AND MODEL USE 34 D&B V8 Speakers Mid-High L/R and Arrays 4 D&B V12 Speakers Mid-High L/R and Arrays 8 D&B V-Sub Speakers *both L/R and

More information

JCCSF AUDIO INFORMATION - KANBAR HALL

JCCSF AUDIO INFORMATION - KANBAR HALL JCCSF AUDIO INFORMATION - KANBAR HALL (REVISED 6, DECEMBER 2018) MAIN STEREO 3-WAY LOUD SPEAKER SYSTEM L-Acoustics ARCS 2-way loudspeaker L-Acoustics dv-sub subwoofer (2/side flown in a horizontal array)

More information

Ramsey Recital Hall Technical Information Packet 2017 General Information:

Ramsey Recital Hall Technical Information Packet 2017 General Information: General Information: Location: Ramsey Recital Hall is located in the Performing Arts Center building at the Performing and Visual Arts Complex off River Road in Athens Ga. River Road can be accessed from

More information

AUDIO -VISUAL SPEC SHEET

AUDIO -VISUAL SPEC SHEET AUDIO -VISUAL SPEC SHEET Please note that not all equipm ent is available for each event. Please m ake reservation requests 4-6 w eeks in advance of your event w ith the Brow er Center Events Departm ent.

More information

Theatre Technical Specifications

Theatre Technical Specifications Theatre Technical Specifications Seating Capacity: The Lakes Theatre STAGING INFORMATION Total 1200 seats Stage Dimensions: Width at widest Part 18m Rear stage width- 13m Stage depth (at centre) 7.4m Height

More information

Jeanne and Peter Lougheed Performing Arts Centre

Jeanne and Peter Lougheed Performing Arts Centre Theatre Technical Specifications Seating Capacity: 584 Seats Maximum 573 with basic holds (7 seats removed for sound console, 4 FOH Holds) (Space for sound console at the back of the orchestra level is

More information

TECHNICAL EQUIPMENT INFORMATION THE NORMAN ROTHSTEIN THEATRE Updated: November 2018

TECHNICAL EQUIPMENT INFORMATION THE NORMAN ROTHSTEIN THEATRE Updated: November 2018 Stage Specifications: Stage Dimensions: Apron Dimensions: Proscenium Arch: Backstage Crossover: Wing space is limited Proscenium to upstage traveler 6.71 meters deep by 10.67 meters wide The apron down

More information

Donald W. Reynolds Performance Hall Technical Information for Touring Companies

Donald W. Reynolds Performance Hall Technical Information for Touring Companies Donald W. Reynolds Performance Hall Technical Information for Touring Companies General Information Mailing Address UCA Public Appearances 201 Donaghey Avenue Stanley Russ Hall 225 Conway, AR 72035 Street

More information

Green Room: Fridge, microwaves and tea and coffee making facilities (tea and coffee available subject to small donation)

Green Room: Fridge, microwaves and tea and coffee making facilities (tea and coffee available subject to small donation) Salberg - Technical Information Visiting Company Specification Updated February 2018 STAGE Stage Information: Width: 8300 Max Upstage, 5000 Max between seating blocks Depth: 7000 Max, 3500 Max between

More information

TEATR GROTESKA ul. SKARBOWA KRAKÓW TEL Update

TEATR GROTESKA ul. SKARBOWA KRAKÓW TEL Update TEATR GROTESKA Technical data The Groteska Theatre Hall Theater Stage location: 1 floor Auditorium: 276 seats, additional seats : 18 Stage area: 70m 2 Proscenium opening: height 4,10m, width 5,94m Stage

More information

MULTI-PURPOSE AUDITORIUM SOUND REINFORCEMENT SYSTEM DESIGN ECE SPRING 2013 SPEAK EASEIES

MULTI-PURPOSE AUDITORIUM SOUND REINFORCEMENT SYSTEM DESIGN ECE SPRING 2013 SPEAK EASEIES MULTI-PURPOSE AUDITORIUM SOUND REINFORCEMENT SYSTEM DESIGN ECE 40020 SPRING 2013 SPEAK EASEIES Matt Carrol EASE and couch enthusiast John Sandvig Master of cheese and EASE Trevor Brown- Devourer of cookies

More information

Huntsville Algonquin Theatre AUDIO INVENTORY

Huntsville Algonquin Theatre AUDIO INVENTORY Huntsville Algonquin Theatre AUDIO INVENTORY FOH Audio Console 1 Yamaha CL5 Note: Audio booth located aprox 50' from stage under short balcony, slightly stage right of centre. Booth area is 6'd x 8'w.

More information

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring 2018 Group 4

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring 2018 Group 4 Multi-Purpose Auditorium Sound Reinforcement System Design ECE 40020 Spring 2018 Group 4 From Left to Right: Derek Tenny, Devin Clausen, Zack Bennett Outline Primary System Design Constraints Venue Illustration

More information

Hodgson Concert Hall Technical Information Packet 2017

Hodgson Concert Hall Technical Information Packet 2017 General Information: Location: Hodgson Concert Hall is located in the Performing Arts Center building at the Performing and Visual Arts Complex off River Road in Athens, GA. River Road can be accessed

More information

Mike Conaway Trent Marshall Brad Sliga Andrew Hanson

Mike Conaway Trent Marshall Brad Sliga Andrew Hanson Multi-Purpose Auditorium Sound Reinforcement System Design ECE 40020 Spring 2013 Mike Conaway Trent Marshall Brad Sliga Andrew Hanson Outline Primary System Design Constraints Venue Illustration System

More information

Palm Beach State College Eissey Campus Theatre Last revised: Jan General Technical Specifications Stage Dimensions:

Palm Beach State College Eissey Campus Theatre Last revised: Jan General Technical Specifications Stage Dimensions: Palm Beach State College Eissey Campus Theatre Last revised: Jan. 2015 General Technical Specifications Stage Dimensions: Proscenium Width: 44-0 Height of grid at stage floor: 70-0 Proscenium Height 22-0

More information

THE CLAYTON CENTER TECHNICAL INFORMATION PACKET

THE CLAYTON CENTER TECHNICAL INFORMATION PACKET THE CLAYTON CENTER TECHNICAL INFORMATION PACKET AS OF JANUARY 2016 THE CLAYTON CENTER TECHNICAL INFORMATION PACKET Thank you for considering the The Clayton Center for your performances. This technical

More information

Stage size: Height: 0,8m Depth: 5m Width: 6,75m Clearance: 2,3m - 4m (slanted roof) + additional working space behind the backdrop (Black Molton)

Stage size: Height: 0,8m Depth: 5m Width: 6,75m Clearance: 2,3m - 4m (slanted roof) + additional working space behind the backdrop (Black Molton) 1 / 5 KERUBIN SALI VENUE INFO & TECHNICAL DETAILS Updated 23rd Mar 2018 GENERAL INFORMATION Venue address: Siltakatu 1 (Ilosaari) 80100 JOENSUU, Finland https://goo.gl/maps/0fl4w Capacity: 450 standing

More information

TECH RIDER 7 DAYS IN ALASKA

TECH RIDER 7 DAYS IN ALASKA 1 av 5 TECH RIDER 7 DAYS IN ALASKA Contacts Kickstart Booking: Band og technician: Jørgen Bertelsen Ole Gunnersen jorgen@ksbooking.no ole@gunnersen.no tlf: +47 980 34 060 tlf: +47 950 93 843 This rider

More information

Eastern Connecticut State University Office of Student Center/Activities

Eastern Connecticut State University Office of Student Center/Activities Lobby Picture of Lobby Stage from corner Picture of Lobby from Stage Picture of Lobby Stage from center Please note that while the lobby is available to reserve, the area does not close for specific events

More information

Multi-Purpose Auditorium. Sound Reinforcement System Design. ECE Spring 2018 Team 3

Multi-Purpose Auditorium. Sound Reinforcement System Design. ECE Spring 2018 Team 3 Multi-Purpose Auditorium Sound Reinforcement System Design ECE 40020 Spring 2018 Team 3 Trey Overholser, Luke Molloy, Tom Kearns, Michael Furnish Slide # 1 of 22 Outline Primary System Design Constraints

More information

NOTTINGHAM LAKESIDE ARTS DJANOGLY THEATRE TECHNICAL INFORMATION

NOTTINGHAM LAKESIDE ARTS DJANOGLY THEATRE TECHNICAL INFORMATION If we do not receive your technical requirements and a lighting plan on Lakeside s plan at least four weeks before your visit, pre-rigging cannot be guaranteed. Please note that we will not pre-rig using

More information

Campbell Heritage Theatre. Technical Information.

Campbell Heritage Theatre. Technical Information. www.heritagetheatre.org Stephen Milligan Production Manager Heritage Theatre 408.981.6785 heritage_production@yahoo.com Address: 1 W. Campbell Avenue Campbell, CA 95008 Box Office telephone: 408.866.2700

More information

Technical Rider. Latest revision March 2017 ABBA-Salutely 70 s Show Director: Sammy Pawlak,

Technical Rider. Latest revision March 2017 ABBA-Salutely 70 s Show Director: Sammy Pawlak, Latest revision March 2017 ABBA-Salutely 70 s Show Director: Sammy Pawlak, sammypawlak@yahoo.com 407-492-8028 Technical Rider The following Technical Rider is provided by ABBA-Salutely 70 s to ensure the

More information

FRONT HOUSE AND BACKSTAGE

FRONT HOUSE AND BACKSTAGE Technical Rider FRONT HOUSE AND BACKSTAGE - The Cinema-Theatre is equipped for cinema, theatre, music, dance and conferences. - It has a seating capacity of 219, 3 being suitable for wheelchairs. - Lift

More information

TECHNICAL RIDER AUDIO - MAINSTAGE F.O.H. CONSOLE F.O.H. DRIVE MONITOR SPEAKER MONITOR CONSOLE P.A. LINE ARRAY 4 WAY

TECHNICAL RIDER AUDIO - MAINSTAGE F.O.H. CONSOLE F.O.H. DRIVE MONITOR SPEAKER MONITOR CONSOLE P.A. LINE ARRAY 4 WAY AUDIO - MAINSTAGE TECHNICAL RIDER P.A. LINE ARRAY 4 WAY F.O.H. CONSOLE F.O.H. DRIVE MONITOR SPEAKER MONITOR CONSOLE 16 PROEL AXIOM AX3210P Diffusor Line Array 3 way Bi-amp, Driver 1x10 LF 1x4 MF 1x2 HF,

More information

Monitor System. Microphone System. D.I Box AMPS KEYBOARD

Monitor System. Microphone System. D.I Box AMPS KEYBOARD C10 LIVEWAREHOUSE Technical Rider FOH System Avid Venue Profile Digital Console 1 FOH MixRack with SC48 Stage Rack 48 Mic / Line Input 32 Line Output Crown I-Tech 3500 HD Power Amp 4 Processor Included

More information

TECHNICAL RIDER OCTOBER 2015

TECHNICAL RIDER OCTOBER 2015 TECHNICAL RIDER OCTOBER 2015 1004 St-Catherine Est, Montréal, Québec, H2L 2G2, Canada Tel.: 514-845-3524 TABLE OF CONTENTS Address Parking and loading dock Stage Stage curtains Dressing rooms Truss and

More information

A U D I O V I S U A L P A C K E T

A U D I O V I S U A L P A C K E T A U D I O V I S U A L P A C K E T W W H Y O P C C A D V A N T A G E S C O S T S A V I N G S E X C E L L E N T E X E C U T I O N Latest equipment and technology 16:9 Aspect Ratio screens and projectors

More information

Price List for Lease of Facilities and Equipment of the Concert Hall Great Amber

Price List for Lease of Facilities and Equipment of the Concert Hall Great Amber Price List for Lease of Facilities and Equipment of the Concert Hall Great Amber Great Hall Specification total area 1170 m 2 ceiling height 23.70 m Inclined floor with a possibility to level the stalls

More information

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring Rahul Sarma - Ishaan Kohli - Matt Jordan

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring Rahul Sarma - Ishaan Kohli - Matt Jordan Multi-Purpose Auditorium Sound Reinforcement System Design ECE 40020 - Spring 2014 Rahul Sarma - Ishaan Kohli - Matt Jordan Overview Primary System Constraints Venue Illustration System Design Constraints

More information

Donald W. Reynolds Performance Hall Technical Information for Touring Companies

Donald W. Reynolds Performance Hall Technical Information for Touring Companies Donald W. Reynolds Performance Hall Technical Information for Touring Companies General Information Mailing Address UCA Public Appearances 201 Donaghey Avenue Stanley Russ Hall 225 Conway, AR 72035 Street

More information

A. SOUND REINFORCEMENT

A. SOUND REINFORCEMENT McCALLUM THEATRE AUDIO-VIDEO June 1, 2017 The room has been described as "live (as in loud) and dry." RT-60 is

More information

Equipment Catalogue Communication Studies and Journalism

Equipment Catalogue Communication Studies and Journalism Equipment Catalogue Communication Studies and Journalism Communication Studies FILM VIDEO 1 - COMS 284 - Canon 60D Kit (included: Roland portable recorder, USB cable) - FV1 Light Kit (included: 2 Tota

More information

See the lakeside website for up-to-date tech spec and drawings

See the lakeside website for up-to-date tech spec and drawings Updated Sept 208 General Venue Information See the lakeside website for up-to-date tech spec and drawings https://www./technical.html 0m x 0m Maximum Performance Area Dimensions (See Ground Plan for Details)

More information

2016/2017 Technical Specifications. FOH Sound System. FOH Mains: 2- Meyer MSL-4 (1 Above, 1Below) + 1- Meyer DF-4P per side

2016/2017 Technical Specifications. FOH Sound System. FOH Mains: 2- Meyer MSL-4 (1 Above, 1Below) + 1- Meyer DF-4P per side 2016/2017 Technical Specifications FOH Sound System FOH Mains: 2- Meyer MSL-4 (1 Above, 1Below) + 1- Meyer DF-4P per side 2- Meyer PSW-2 Dual 15 Subwoofers 2- Meyer UPM-1P Center Fills (Optional) 25- TOA

More information

(English) Stage. Stage area is 12 meters wide and 9 meters deep.

(English) Stage. Stage area is 12 meters wide and 9 meters deep. Stage (English) Stage area is 12 meters wide and 9 meters deep. Full depht of stage: 11,4m Height from stage floor to ceiling: 12,9m Stage side area: W= 8,6m x D= 4,7m (Stage Right) Proscenie height: 6m

More information

COMMUNICATION STUDIES

COMMUNICATION STUDIES INTERMEDIA 1 COMS 274 COMMUNICATION STUDIES Projector Kodak Playfull video camera Canon Powershot camera Roland 026 recorder Zoom H4 recorder Zoom H4N recorder Shotgun mic Boom pole XLR mic cable Wireless

More information

Under The Radar Technical Rider

Under The Radar Technical Rider Under The Radar Technical Rider Scope This Technical Rider shall define the requirements for the Under The Radar (The Artists) Front of House (FOH), Monitor Mix sound system, stage dimensions, stage AC

More information

The Bridgewater Hall Technical Specifications

The Bridgewater Hall Technical Specifications The Bridgewater Hall Technical Specifications General Information Capacity (Maximum) Fixed seating auditorium: 2341 on four levels, including 16 wheelchair spaces Artist s Rooms/Orchestra Rooms/Production

More information

Technical Specification 2017

Technical Specification 2017 Technical Technical For further information please contact Millfield.Technical@Enfield.gov.uk Technical Department:0208 887 7315 www.millfieldtheatre.co.uk,, Updated: February 2016 Technical Seating Capacities:

More information

Ford Theaters Ford Amphitheater and [Inside] the Ford

Ford Theaters Ford Amphitheater and [Inside] the Ford Ford Theaters Ford Amphitheater and [Inside] the Ford FOH PA System NOTE: 95 db SPL Limit enforced at FOH "A" System 6 EAW KF 650z 3-way L/R 3 left, 3 right ground stacked on platforms powered by Crest

More information

Sinplus Up To Me (2014) Full Band - Technical Rider

Sinplus Up To Me (2014) Full Band - Technical Rider Sinplus Up To Me (2014) Full Band - Technical Rider Technical contact Marzio Picchetti Technical Director/Light Engineer + 41798132246 info@marziopicchetti.com This Technical Rider constitutes an integral

More information

DATA. Address: Av. Carrilet, 235 L Hospitalet - Barcelona

DATA. Address: Av. Carrilet, 235 L Hospitalet - Barcelona ! DATA Address: Av. Carrilet, 235 L Hospitalet - Barcelona Transports: There are very near two underground stations (Av. Carrilet and Rambla Just Oliveras), differents bus stops and Ferrocarrils Catalans

More information

KENAI PENINSULA BOROUGH SCHOOL DISTRICT Purchasing Department 139 E. Park Avenue Soldotna, Alaska (907) FAX (907)

KENAI PENINSULA BOROUGH SCHOOL DISTRICT Purchasing Department 139 E. Park Avenue Soldotna, Alaska (907) FAX (907) Page 1 of 9 Bid 114-13 Item 01 AMPLIFIER, 2 CHANNEL POWERED 19"W x 3.5"H x 14"D - 21 lbs. QSC CX302 $734.00 $834.99 $740.00 $832.58 $852.11 $730.00 Washington Professional $730.00 02 AMPLIFIER, PROFESSIONAL

More information

DROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre

DROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre DROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre Technical Rider V2 - Trio Version TEAM & SCHEDULE The following technical rider presents the Trio version of Drops & Points. It is a modular live

More information

Updated Fall IX. Recording and Playback imac (Early 2014 model) Whirlwind PodDI for ipod/iphone

Updated Fall IX. Recording and Playback imac (Early 2014 model) Whirlwind PodDI for ipod/iphone Video Suite Behringer U-PHORIA UM2 Audiophile 2x2 USB Audio Interface with XENYX Mic Preamplifier Mackie CR4 (Pair) Creative Reference Multimedia Monitor Blue Microphones Yeti USB Microphone Dell UltraSharp

More information

VISHAL AND SHEKHAR. AUDIO AnD VIDEO TECHnICAL RIDER 2012.A

VISHAL AND SHEKHAR. AUDIO AnD VIDEO TECHnICAL RIDER 2012.A VISHAL AND SHEKHAR AUDIO AnD VIDEO TECHnICAL RIDER 2012.A Please go through each Page of this rider thoroughly so that all equipment is correctly provided for the event. All exceptions /substitutions must

More information

CAPACITY 650 Kapelstraat 13, 5401 EC Uden PHONE 0031 (0) FAX 0031 (0) IMPORTANT NOTES PROHIBITED SMOKING

CAPACITY 650 Kapelstraat 13, 5401 EC Uden PHONE 0031 (0) FAX 0031 (0) IMPORTANT NOTES PROHIBITED SMOKING VENUE DE PUL HALL MAIN HALL CAPACITY 650 ADDRESS Kapelstraat 13, 5401 EC Uden PHONE 0031 (0)413-265091 FAX 0031 (0)413-266125 WEB www.livepul.com PROHIBITED SMOKING GET-IN SETTLEMENT LOCAL CREW SECURITY

More information

MODEL DESCRIPTION QTY. PS15 NEXO PS15 R2 Single Cabinet 9. PS10 NEXO PS10 R2 Single Cabinet 6. RS18 NEXO RS18 Raysub 4

MODEL DESCRIPTION QTY. PS15 NEXO PS15 R2 Single Cabinet 9. PS10 NEXO PS10 R2 Single Cabinet 6. RS18 NEXO RS18 Raysub 4 #SPEAKERS... Updated 28 September 2018 (HIRE LIST) PS15 NEXO PS15 R2 Single Cabinet 9 A high power system capable of producing 136dB Peak SPL. With up to 2000W of amplifier power PS10 NEXO PS10 R2 Single

More information

III - SOUND RIDER Bixiga 70 European Tour 2017

III - SOUND RIDER Bixiga 70 European Tour 2017 III - SOUND RIDER FOH - Console 48 Input CH - Compressors (as shown in input list) - Noise gates (as shown in input list) - 03 multi-effects processors - 1/3 octave equalizer in L/R - 01 spectrum analyser

More information

Jeanne and Peter Lougheed Performing Arts Centre

Jeanne and Peter Lougheed Performing Arts Centre Facility Information Jeanne and Peter Lougheed The Jeanne and Peter Lougheed is located at 4501 50 th Street in Camrose, Alberta. We are situated on the University of Alberta Augustana Campus, alongside

More information

HIRE PRICE LIST JUNE 2009

HIRE PRICE LIST JUNE 2009 Optical Audio Productions 16a Palmer Parade Cremorne Victoria Australia 3121 Phone 03 9416 3666 Fax 03 9387 1872 Email info@oaproductions.com.au Web www.oaproductions.com.au www.opticalaudio.com.au AUDIO

More information

A SPECIAL VENUE FOR SPECIAL EVENTS

A SPECIAL VENUE FOR SPECIAL EVENTS A SPECIAL VENUE FOR SPECIAL EVENTS Technical Rider Théâtre Desjardins is managed by the Société de la salle Jean-Grimaldi. It s main partners are the Borough of LaSalle and André-Laurendeau Cegep. Equipped

More information

II. MICROPHONE PREAMPLIFIERS

II. MICROPHONE PREAMPLIFIERS 2000 Mallory Lane 16057 Tampa Palms Blvd. Suite 130 110 West #364 Franklin, TN 37067 Tampa, FL 33647 Phone: (615) 794-5246 Phone: (813) 986-4477 Email David Habegger: davidh@watermarkinc.net Facsimile:

More information

CLIENT TO SUPPLY: OTHER BANDS: please make you own copy rather than copy/paste ours!

CLIENT TO SUPPLY: OTHER BANDS: please make you own copy rather than copy/paste ours! WB PRODUCTIONS WildBoys Technical Rider for Theatre shows, Jan 2018 Telephone Steve on +44 (0)7776 127 468 with any queries. If any of the items listed are not available and substitutions need to be made

More information

GECC Theatre Technical Specifications

GECC Theatre Technical Specifications GECC Theatre Technical Specifications Senior Technician: Jayden Allen Mobile: 0417 097 992 Landline: 07 4972 2822 Email: JaydenA@gladstone.qld.gov.au Venue: Phone: 07 4972 2822 Website: www.gladecc.com.au

More information

RIDER. mobile phone: +32 (0)

RIDER.  mobile phone: +32 (0) RIDER www.solitudewithin.be main contact Name: Jean-Paul Laffargue mobile phone: +32 (0) 475 654825 email: jp@solitudewithin.be 1. TECHNICAL RIDER We play with In-ear monitors and provide in our own monitor

More information

EQUIPMENT LIST I. CONSOLES

EQUIPMENT LIST I. CONSOLES EQUIPMENT LIST I. CONSOLES Amek Rembrandt 80 input at mixdown o 24 buss o 16 aux sends o 4 band semi parametric EQ on all 80 inputs o 40 microphone preamps o Supertrue mix automation o Total Recall o Virtual

More information

RPA Sound hire prices 2015

RPA Sound hire prices 2015 Item per day per week Speaker cabinets d & b Y8 80 x 14 Deg 35.00 105.00 d & b Y12 110 x 14 Deg 35.00 105.00 d & b Y sub, cardiod 18 and 12 35.00 105.00 d & b J8 80 x 7 deg 60.00 180.00 d & b J12 120 x

More information

Rider 7NA Name: Maaike Schottink Name: Oscar Otten Mobile phone: Mobile phone:

Rider 7NA Name: Maaike Schottink Name: Oscar Otten Mobile phone: Mobile phone: Rider 7NA 2017 Contact details General information: E-mail adress: Website: info@7na.nl (managed by Oscar Otten) www.7na.nl Management, planning, finance: Technique, marketing & Social Media: Name: Maaike

More information

THEATRE SPECIFICATIONS FOR WILLOW THEATRE

THEATRE SPECIFICATIONS FOR WILLOW THEATRE THEATRE SPECIFICATIONS FOR WILLOW THEATRE Booking Coordinator Stacee Lanz 561.347.3901 slanz@myboca.us Technical Theatre Supervisor Jason Hester 561.347.3914 jhester@myboca.us Facility Information Willow

More information

Sound Technical Rider Yellow Umbrella 2017 Tour Problems with this rider? We can find a solution! Jörg: GSM:

Sound Technical Rider Yellow Umbrella 2017 Tour Problems with this rider? We can find a solution! Jörg: GSM: Sound Technical Rider Problems with this rider? We can find a solution! Jörg: joergstocker@hotmail.com GSM: +49 171 1936955 P.A. Specs: P.A. must be of professional quality, minimum 3 ways active plus

More information

Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222

Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222 (Revised December 2015) Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222 PAC STAFF Director of Operations Jeff Marsha 716-878-3599 marshajl@buffalostate.edu

More information

The Crossing Venue Information & Specification 2013

The Crossing Venue Information & Specification 2013 THE CROSSING VENUE INFO & SPECIFICATION 1 The Crossing Venue Information & Specification 2013 Phone: 0121 694 5000 8am - 8pm Mon-Thurs 8am - 5pm Fri Outside UK please call +44 121 694 5000 Email: events@sccb.ac.uk

More information

Hult Center for the Performing Arts Technical Specifications

Hult Center for the Performing Arts Technical Specifications Hult Center for the Performing Arts Technical Specifications Silva Concert Hall Technical Director, Brian Ference Asst Technical Director, Mike Carpenter.... Brian.R.Ference@ci.eugene.or.us Michael.C.Carpenter@ci.eugene.or.us

More information

DROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre

DROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre DROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre Technical Rider - Extended Version V2 TEAM & SCHEDULE The following technical rider presents the extended version of Drops & Points. It is a modular

More information

Technical Specifications Black Box

Technical Specifications Black Box Table of Contents 1. General Information: 2. Audio & Video: 3. Lighting: 4. Staging: 1.1. Equipment Set Up & Operation 1.2. Electrical Safety 1.3. Power Supply 2.1. Mixing Console 2.2. Playback 2.3. Standard

More information

Sweet Adelines Microphone and Sound System Guidelines

Sweet Adelines Microphone and Sound System Guidelines Page 1 Sweet Adelines Microphone and Sound System Guidelines This document establishes a common source of microphone and sound system guidelines for the members of the Sweet Adelines. These guidelines

More information

!www.vicferrari.com!

!www.vicferrari.com! Willie Harrison, manager 558 Eisenhower Drive - Suite H Kimberly, WI 54136 920-997-9940 www.vicferrari.com https://www.facebook.com/thevicferrariband #VicFerrari on Instagram Production Rider for Fly Dates

More information

Always check availability of equipment Additional charges may apply PLEASE NOTE Stock availability may differ due to repairs etc

Always check availability of equipment Additional charges may apply PLEASE NOTE Stock availability may differ due to repairs etc Technical Specifications SEATING CAPACITY Auditorium with no sound position: 366 Auditorium with sound position: 351 Auditorium with pit covered: 323 Sound position equates to 15 seats Four seats are reserved

More information

TECHNICAL RIDER. 4. Dinner Dinner shall be after sound check. Please refer to Hospitality Rider for details.

TECHNICAL RIDER. 4. Dinner Dinner shall be after sound check. Please refer to Hospitality Rider for details. TECHNICAL RIDER This Technical Rider covers the basics of a Guy Mendilow Ensemble performance. It is hereby attached to the Contract between the parties named herein. Any changes must be approved by both

More information

bellowhead Last Updated March Up to date spec available at

bellowhead Last Updated March Up to date spec available at Last Updated March 3 2007 Up to date spec available at http://web.mac.com/markwhyles/iweb/site/bellowhead.html The tech spec, stage plan and channel list within, form part of the contract. Failure to meet

More information

UrbanFox.TV MORE IMPORTANT SOUND IS THAN THE PICTURES. A few questions. Simple Sound Advice. All of this presentation will go on our website

UrbanFox.TV MORE IMPORTANT SOUND IS THAN THE PICTURES. A few questions. Simple Sound Advice. All of this presentation will go on our website Urban.TV Urban.TV Simple Sound Advice All of this presentation will go on our website www.urbanfox.tv/seminar A few questions How many of you shoot your own stuff or expect to in the future? How many work

More information

ECE40020 Venue Design. Sean Obrecht, Bryan Marquet, Aditya Sharma, Ben Capano

ECE40020 Venue Design. Sean Obrecht, Bryan Marquet, Aditya Sharma, Ben Capano ECE40020 Venue Design Sean Obrecht, Bryan Marquet, Aditya Sharma, Ben Capano Overview Preliminary Design Constraints Design Constraint Satisfaction Venue Illustrations Equipment Selection Results / Simulations

More information

UPTOWN THEATRE GENERAL MANAGER: ext. 2 UPTOWN THEATRE PRODUCTION MANAGER:

UPTOWN THEATRE GENERAL MANAGER: ext. 2 UPTOWN THEATRE PRODUCTION MANAGER: ADDRESS: Physical and Postal The Uptown Theatre 1350 Third St. Napa, California 94559 PHONE: 707.259.0123 FAX: 707.259.0333 WEBSITE: www.uptowntheatrenapa.com TECHLINK: www.uptowntheatrenapa.com/technical-info

More information

Bedford Corn Exchange Main Auditorium Technical information

Bedford Corn Exchange Main Auditorium Technical information Bedford Corn Exchange Main Auditorium Technical information AUDIO TTL33-A line array module The TTL33 line array module has a wide, constant directivity, coverage angle, with six high power neodymium transducers,

More information

TECHNICAL RIDER Amjad Ali Khan & Amaan Ali Bangash and Ayaan Ali Bangash

TECHNICAL RIDER Amjad Ali Khan & Amaan Ali Bangash and Ayaan Ali Bangash TECHNICAL RIDER Amjad Ali Khan & Amaan Ali Bangash and Ayaan Ali Bangash PERFORMANCE AGREEMENT. This technical rider should be read as soon as received by the presenter. The presenter will endeavour to

More information

What s New in 2013! We offer over 700 top brands, low prices and outstanding service. NEW BRANDS. Hand built guitar effects pedals, made in the USA.

What s New in 2013! We offer over 700 top brands, low prices and outstanding service. NEW BRANDS. Hand built guitar effects pedals, made in the USA. N2 NEW BRANDS Hand built guitar effects pedals, made in the USA. Quality vintage-style acoustic guitars and banjos that are built to stand the test of time. Born from a group of lighting designers, ChamSys

More information

Jazzclub Unterfahrt Munich -Technical Rider 09/2017

Jazzclub Unterfahrt Munich -Technical Rider 09/2017 Jazzclub Unterfahrt Munich -Technical Rider 09/2017 Equipment available on location: Front-of-House: Mixing Desk: Soundcraft VI1 digital desk w/vi CSB 16 RJ 45 stagebox P.A.: Alcons Power Amps: 2 x ALC4,

More information

FOLKEN STORSALEN - FOH Production Specs - General Information

FOLKEN STORSALEN - FOH Production Specs - General Information FOLKEN STORSALEN - FOH Production Specs - General Information Venue Promoter Visiting address Postal address Vat ID Folken Storsalen Studentersamfunnet Folken Løkkeveien 24 4008 Stavanger Norway Postboks

More information

Venue info Studentersamfundet, Trondheim, Norway

Venue info Studentersamfundet, Trondheim, Norway Venue info Studentersamfundet, Trondheim, Norway Update: 11.jan.2017 Venue Capacity Venue type Address Parking Load in Stage Dressing rooms Internett Mixer position House PA Power Klubben (the Club) 300

More information

Technical Specifications THEATRE

Technical Specifications THEATRE Table of Contents 1. General Information: 1.1. Seating Capacity 1.2. Equipment Set Up & Operation 1.3. Electrical Safety 1.4. Power Supply 2. Audio & Video: 3. Lighting: 2.1. Mixing Console 2.2. Playback

More information

PINK TURTLE THEATRE RIDER

PINK TURTLE THEATRE RIDER PINK TURTLE THEATRE RIDER This rider is part of the contract: please read it carefully, don t hesitate to call us to get more information. Remember we can always find solutions providing we have reasonable

More information

Robert Bolt Theatre. Technical Rider

Robert Bolt Theatre. Technical Rider Robert Bolt Theatre Technical Rider 1 Waterside Plaza Sale Waterside Sale Cheshire M33 7ZF (Updated 05.11.2014) Quick List Robert Bolt Theatre Get In- Via Main Entrance No stairs. Smallest door to reach

More information

Pro Audio - Large Diaphragm Recording Microphones

Pro Audio - Large Diaphragm Recording Microphones Pro Audio - Large Diaphragm Recording Microphones 1 AKG C214 Large-Diaphragm Condenser Microphone * Cardioid Pattern * 1-Inch Capsule & Low-Cut Filter * 143 db Dynamic Range * Integrated Capsule Suspension

More information

Peter Britt Festivals Audio Specification 2017

Peter Britt Festivals Audio Specification 2017 Peter Britt Festivals Audio Specification 2017 Audio Contractor George Relles Sound, Inc. EST 1975 Contact: George Relles Ph/Fx 541.686.9325 Mobile 541.915.7230 E-mail grelles@msn.com FOH Console: AVID

More information

TECHNICAL RIDER Amjad Ali Khan & Amaan Ali Bangash and Ayaan Ali Bangash

TECHNICAL RIDER Amjad Ali Khan & Amaan Ali Bangash and Ayaan Ali Bangash TECHNICAL RIDER Amjad Ali Khan & Amaan Ali Bangash and Ayaan Ali Bangash PERFORMANCE AGREEMENT. This technical rider should be read as soon as received by the presenter. The presenter will endeavour to

More information

CONTACTS. Pantages Theatre 710 Hennepin Avenue Minneapolis, MN Steve Olson Operations Coordinator Phone: (612) Fax: (612)

CONTACTS. Pantages Theatre 710 Hennepin Avenue Minneapolis, MN Steve Olson Operations Coordinator Phone: (612) Fax: (612) Pantages Theatre 710 Hennepin Avenue Minneapolis, MN 55403 CONTACTS Steve Olson Operations Coordinator Phone: (612) 373-5654 Fax: (612) 746-3153 Gail Nelson Chief Operating Officer (612) 373-5673 Rick

More information

Technical specifications Short Format Subject to alteration-please call us to confirm details.

Technical specifications Short Format Subject to alteration-please call us to confirm details. 1. Belmont Street, Bognor Regis West Sussex. PO21 1BL tech@regiscentre.co.uk iain.jordan@regiscentre.co.uk Tel / Fax: 01243 867676 Box Office: 01243 861010 Technical specifications Short Format Subject

More information