1 Data sheet Sight glass (Low pressure) s SG, SGI, SGN, SGR, SGRI and SGRN SG is sight glasses for low pressure application (Max Working Pressure 35 bar / 500 psig). SG is available with flare, solder and socket connections, and with and without moisture indicators. SGI / SGN and SGRI / SGRN are equipped with sensitive indicators that reflects a color, which depends on the moisture content in the refrigerant. SG and SGR, without moisture indicator, are mainly used to indicate the condition of the refrigerant in the liquid line or the flow in the oil return line from the oil separator. Features SG / SGR (without indicator) Indicates lack of subcooling Indicates refrigerant deficiency Indicates liquid level in receiver Indicates oil level in compressor Solder / solder connection or socket type SGI / SGRI (with I type indicator) For refrigerants with mineral oil, e.g. R22 Indicates too high water content in the refrigeration system Indicates lack of subcooling Indicates refrigerant deficiency Flare / flare, solder / solder connection or socket type SGN / SGRN (with N type indicator) For refrigerants: R22, R34a, R404A, R407C, R507, R407A, R407F, R448A, R449A, R450A, R452A, R53A Indicates too high water content in the refrigeration system Indicates lack of subcooling Indicates refrigerant deficiency Flare / flare, solder / solder connection or socket type DKRCC.PD.EK0.A8.02
2 Available types Flare Internal x External Solder version ODF x ODF SGI and SGN with indicator SG without indicator Solder version ODF x ODM Solder version ODF x ODF Flare external x External SGI and SGN with indicator SGI and SGN with indicator SGI and SGN with indicator Socket Socket Saddle SGR without indicator SGRI and SGRN with indicator SGS Choice of sight glass moisture indication Note: when storing, transporting or installing the Sight Glass, avoid the chemical indicator to get in contact with non-refrigerant medium or fluid (like water, oil, ect.) Before choosing a sight glass with moisture indicator, the following should be considered: type of refrigerant water solubility of refrigerant the level on which a danger signal is required Be aware that polyester oil for non-flammable refrigerants, e.g. R34a, R404A, R407C react with water in a hydrolysis generating acid and alcohol. The recommended levels of moisture content are usually between 30 and 75 ppm, where hermetic compressors only tolerate very low moisture content, while semi-hermetic and other compressors normally tolerate higher moisture contents in the refrigerant. The colour on the sight glass indicator depends on the moisture content of the refrigerant. The values under green / dry are to be considered as perfect condition meaning full protection against harmful effects from moisture. In other words, the filter drier is working perfectly. If the green color starts to fade, the color change has begun and the indicator should therefore be watched more carefully. If the color changes to yellow it is a clear signal that the capacity of the filter drier is exceeded and must be replaced immediately. REAC requirements Note: All products fulfill the requirements in REAC. One of the obligations in REAC is to inform customers about presence of Candidate list substances if any, we hereby inform you about one substance on the candidate list: A moisture indicator in a sight glass contains a paper which is impregnated with Cobalt Dichloride (CAS no: ) in a concentration above 0.% w/w. If the valve has been damaged or dismantled: - Avoid skin contact with the paper - Do not inhale the dust from the paper - The paper must be disposed as hazardous waste DKRCC.PD.EK0.A8.02 2
3 Technical data Media temperature: C / F Max. working pressure (PS / MWP): 35 bar / 500 psig Refrigerant oil: All mineral oils and ester oils SGI / SGRI for refrigerants with mineral oil Refrigerants with mineral oil, e.g. R22 Moisture content ppm = parts per million SGI / SGRI Media temperature 25 C Media temperature 43 C Green / dry Intermed. color Yellow / wet Green / dry Intermed. color Yellow / wet < > 300 < > 500 SGN / SGRN for R22, R34a, R404A, R407C, R507, R407A, R407F, R448A, R449A, R450A, R452A, R53A Moisture content ppm = parts per million SGN / SGRN Media temperature 25 C Media temperature 43 C Green / dry Intermed. color Yellow / wet Green / dry Intermed. color Yellow / wet R22 < > 20 < > 200 R34a < > 00 < > 70 R404A < > 70 < > 00 R407C < > 40 < > 225 R507 < > 60 < > 0 R407A < > 5 < > 92 R407F < >68 < > 240 R448A < > 0 < > 227 R449A < > 05 < > 200 R450A < > 48 < > 245 R452A < > 79 < > 43 R53A < > 75 < > 23 Notes: For colours reflecting moisture values of other refrigerants, please contact For a fully updated list of approved refrigerants, visit and search for individual code numbers, where refrigerants are listed as part of product specifications DKRCC.PD.EK0.A8.02 3
4 Ordering SG without indicator [inch] [mm] SG 0s Solder ODF ODF SG 22s Solder ODF ODF SGI with I type indicator [inch] [mm] SGI 6 Flare ext. ext SGI 0 Flare ext. ext SGI 2 Flare ext. ext SGI 6 Flare ext. ext SGI 9 Flare ext. ext SGI 6 Flare int. ext. ) SGI 0 Flare int. ext. ) SGI 2 Flare int. ext. ) SGI 6 Flare int. ext. ) SGI 9 Flare int. ext. ) Solder ODF ODF SGI 6s Solder ODF ODF Solder ODF ODF SGI 0s Solder ODF ODF Solder ODF ODF SGI 2s Solder ODF ODF SGI 6s Solder ODF ODF SGI 8s Solder ODF ODF SGI 9s Solder ODF ODF SGI 22s Solder ODF ODF SGI 6s Solder ODF ODM SGI 0s Solder ODF ODM SGI 2s Solder ODF ODM SGI 6s Solder ODF ODM SGI 22s Solder ODF ODM ) Can be screwed directly into the filter drier DKRCC.PD.EK0.A8.02 4
5 Ordering (continued) SGN with N type indicator [inch] [mm] SGN 6 Flare ext. ext SGN 0 Flare ext. ext SGN 2 Flare ext. ext SGN 6 Flare ext. ext SGN 9 Flare ext. ext SGN 6 Flare int. ext. ) SGN 0 Flare int. ext. ) SGN 2 Flare int. ext. ) SGN 6 Flare int. ext. ) SGN 9 Flare int. ext. ) SGN 6s SGN 0s SGN 2s Solder ODF ODF Solder ODF ODF Solder ODF ODF Solder ODF ODF Solder ODF ODF Solder ODF ODF SGN 6s Solder ODF ODF SGN 8s Solder ODF ODF SGN 9s Solder ODF ODF SGN 22s Solder ODF ODF SGN 22s 2 ) Solder ODF ODF SGN 6s Solder ODF ODM SGN 0s Solder ODF ODM SGN 2s Solder ODF ODM SGN 6s Solder ODF ODM SGN 22s Solder ODF ODM ) Can be screwed directly into the filter drier 2 ) Oversize connections DKRCC.PD.EK0.A8.02 5
6 Ordering (continued) Socket sight glass without indicator Valve type Indicator type Floating ball [pc] O-ring Multi pack SGR No G thread G 3 4 A ) No SGR No NPT NPT 2 ) No SGR No NPT 2 4 NPT 2 ) 3 No Socket sight glass with indicator SGRI I type NPT 2 4 NPT 2 ) 3 No SGRI I type M thread M24 No Yes SGRN N type NPT 2 4 NPT 2 ) 3 No SGRN N type M thread M24 No Yes ) ISO ) ANSI/ASME B.20. Sight glass saddle Valve type SGS type Tube connection [inch] Industrial pack [pcs] Tube fitting M Tube fitting M Tube fitting M Tube fitting M Tube fitting M Tube fitting M Tube fitting M DKRCC.PD.EK0.A8.02 6
7 Dimensions and weights SGI / SGN flare, int. ext. SGI / SGN flare, ext. ext D D MWP 35 bar/pb 500 psig-max.70 C/60 F WET SGN DANFOSS CINA L B L MWP 35 bar/pb 500 psig-max.70 C/60 F WET SGN DANFOSS CINA B SI Units SGI / SGN 6 L B ød Net weight [mm] [mm] [mm] [mm] [mm] [Kg] SGI / SGN SGI / SGN 2 Flare ext. ext SGI / SGN SGI / SGN SGI / SGN SGI / SGN SGI / SGN 2 Flare int. ext SGI / SGN SGI / SGN US Units SGI / SGN 6 L B ød Net weight [inch] [inch] [inch] [inch] [inch] [lbs] SGI / SGN SGI / SGN 2 Flare ext. ext SGI / SGN SGI / SGN SGI / SGN SGI / SGN SGI / SGN 2 Flare int. ext SGI / SGN SGI / SGN DKRCC.PD.EK0.A8.02 7
8 Dimensions and weights (continued) SG socket MWP 35 bar/pb 500 psig-max.70 C/60 F WET SGRN DANFOSS CINA B SI Units B Net weight [mm] [mm] [mm] [kg] SGR Pipe thread G 3 4 A ) SGR NPT 2 4 NPT 2 ) SGR NPT NPT 2 ) SGRI / SGRN NPT 2 4 NPT 2 ) SGRI / SGRN M thread M ) ISO ) ANSI/ASME B.20. US Units B Net weight [inch] [inch] [inch] [lbs] SGR Pipe thread G 3 4 A ) SGR NPT 2 4 NPT 2 ) SGR NPT NPT 2 ) SGRI / SGRN NPT 2 4 NPT 2 ) SGRI / SGRN M thread M ) ISO ) ANSI/ASME B.20. DKRCC.PD.EK0.A8.02 8
9 Dimensions and weights (continued) SGI / SGN solder ODF ODF D MWP 35 bar/pb 500 psig-max.70 C/60 F WET SGN DANFOSS CINA L B SGI / SGN solder ODF ODM D MWP 35 bar/pb 500 psig-max.70 C/60 F WET SGRN DANFOSS CINA L B L L SI Units SGI / SGN 6s L L B ød Net weight [mm] [mm] [mm] [mm] [mm] [mm] [kg] SGI / SGN 0s SGI / SGN 2s SGI / SGN 6s Solder ODF SGI / SGN 8s ODF SGI / SGN 9s SGI / SGN 22s SGI / SGN 22s ) SGI / SGN 6s SGI / SGN 0s SGI / SGN 2s Solder ODF ODM SGI / SGN 6s SGI / SGN 22s ) Oversize connections US Units SGI / SGN 6s L L B ød Net weight [in.] [in.] [in.] [in.] [in.] [in.] [lbs] SGI / SGN 0s SGI / SGN 2s SGI / SGN 6s Solder ODF SGI / SGN 8s ODF SGI / SGN 9s SGI / SGN 22s SGI / SGN 22s ) SGI / SGN 6s SGI / SGN 0s SGI / SGN 2s Solder ODF ODM SGI / SGN 6s SGI / SGN 22s ) Oversize connections can accept no responsibility for possible errors in catalogues, brochures and other printed material. reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. and the logotype are trademarks of A/S. All rights reserved. DKRCC.PD.EK0.A8.02 9
Sight glass (Low pressure) Types SG, SGI, SGN, SGR, SGRI and SGRN
ata sheet Sight glass (ow pressure) Types SG, SGI, SGN, SGR, SGRI and SGRN SG is sight glasses for low pressure application (Max Working Pressure 500 psig). SG is available with flare, solder and socket
More informationSight glass (Low pressure) Types SG, SGI, SGN, SGR, SGRI and SGRN
ata sheet Sight glass (ow pressure) s SG, SGI, SGN, SGR, SGRI and SGRN SG is sight glasses for low pressure application (Max Working Pressure 500 psig). SG is available with flare, solder and socket connections,
More informationProducts catalogue (I-P Edition)
Products catalogue (I-P Edition) Products catalogue (I-P Edition) FROM QUALITY OUR NATURAL DEVELOPMENT Active in the industry of Refrigeration and Air Conditioning for fifty-five years, Castel is well-established
More informationInstructions for Stone Cutting Machine
Technical data Kg. Instructions for Stone Cutting Machine SCM600 3HP 2800rpm IP55 SCM800 3HP 2800rpm IP55 SCM1000 2800rpm IP55 SCM1200 2800rpm IP55 L=600 B=85(165) L=800 B=85(175) 500x510 0 or 45 600lt/h
More informationPressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350
Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350 Technical brochure Features Designed for use in severe maritime environments For medium and ambient temperatures
More informationDrill INSTRUCTION MANUAL. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE 1 REFERENCE.
ENGLISH (Original instructions) INSTRUCTION MANUAL Drill 6411 6412 6413 007894 DOUBLE INSULATION WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE
More informationENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DOUBLE INSULATION. IMPORTANT: Read Before Using.
ENGLISH (Original instructions) INSTRUCTION MANUAL Drill 64 642 643 007894 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model 64 642 643 Capacities Steel
More information2-pole design. New: Semi-hermetic compressors with 2-pole drive motor for mains voltages of 60 Hz. Now for 60 Hz mains voltage
2-pole design Semi-hermetic compressors with 2-pole drive motor for mains voltages of Hz New: Now for Hz mains voltage Baureihe HG series HG 2-pole 2-polig - t a glance t a glance Based on our compressors
More informationENGLISH (Original instructions) INSTRUCTION MANUAL. Drill MT600 MT601 DOUBLE INSULATION. IMPORTANT: Read Before Using.
ENGLISH (Original instructions) INSTRUCTION MANUAL Drill MT600 MT60 003635 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model MT600 MT60 Capacities Steel
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationROUND BENDING MACHINE Model: RBM30
ROUND BENDING MACHINE Model: RBM30 Operation Manual SAVE THIS MANUAL:You will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts
More informationRepair Manual 12 PL PILOT
Repair Manual 12 PL PILOT 12 PL PILOT REPAIR MANUAL INDEX Introduction... 1 Elastomer Materials... 2 Disassembly... 3 Assembly... 7 Testing... 11 NOTE: We reserve the right to modify or change, without
More informationWe appreciate your support to this initiative and remain at your service for any need of clarification to this subject.
Refrigeration and Air Conditioning Controls Refrigeration Note Sales Info At this point of time, this note is only intended for internal use and communication to OEM s. So far this is information about
More informationENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DS4012 DOUBLE INSULATION. IMPORTANT: Read Before Using.
ENGLISH (Original instructions) INSTRUCTION MANUAL Drill DS402 05402 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model DS402 Capacities Steel 3 mm Wood
More informationMotor operated valves and Actuators Type ICM and ICAD
Data sheet Motor operated valves and Actuators Type ICM and ICAD ICM motor operated valves belong to the ICV family and are one of two product groups. ICV types ICS - Pilot operated servo valve ICM - Motor
More informationSF 6 Characteristics and Re-use Concept
DILO. Sustainably tight. SF 6 Characteristics and Re-use Concept www.dilo-gmbh.com Peter Jannick / Solvay Fluor Overview What is sulphur hexafluoride? Decomposition products SF 6 gas specifications IEC
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Protected Bulb Patented reference design for exceptional performance* Mounts in Signet standard fittings from
More informationIntroduction to Filters. Master Pneumatic General Purpose Filters Coalescing Filters
Introduction to Filters Master Pneumatic General Purpose Filters Coalescing Filters Several Types of Filters Remove Contaminants from Compressed Air General Purpose --- Remove water and particulate matter
More information2-Speed Hammer Drill HP2000 HP2020
2-Speed Hammer Drill HP2000 HP2020 SPECIFICATIONS Model HP2000 HP2020 Speed High Low High Low Capacities Concrete 20 mm 20 mm Steel 6.5 mm 13 mm 6.5 mm 13 mm No load speed (min 1 ) 0 2,300 0 900 2,300
More informationFILTRATION PRODUCTS. GIL Series
FILTRATION PRODUCTS GIL Series Why is Compressed Air Filtration Required? The air around you is full of tiny particles that are potentially harmful to the equipment in your operation. These particles can
More informationANALYTICAL - COMPLEXITY MADE SIMPLE
EVITA OXY Dissolved Oxygen Meter DANFOSS ANALYTICAL - COMPLEXITY MADE SIMPLE How it works The EVITA OXY dissolved oxygen meter operates on Clark s principle: To initiate measurement a polarization voltage
More informationValve Island with Electronic I/O
Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication
More informationTYPE 3740 WET RUNNING CARTRIDGE SPLIT SEAL Technical Specification
A Mating Ring B Mating Ring Adapter Assy. C Sealing Element Gasket D Sealing Element Strip E Sealing Element O-ring F Set Screw G Primary Ring H Retaining Ring I Spring Adapter Assy. Set J O-ring (Split)
More informationContent. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...
Flow meter Content F2-UN Description... 3 Technical data... 4 Dimension drawings... Operation... 8 Mounting instructions... 9 Order code... 10 F1-FP Description... 11 Technical Data... 12 Dimension drawings...
More informationSignet ph/orp Electrodes General Purpose
Signet 2724-2726 ph/orp Electrodes General Purpose Compatible with ALL Signet ph/orp instruments and SmartPro transmitters Features Patented reference design for exceptional performance and prolonged life
More informationHigh Speed Drill MODEL WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
ENGLISH High Speed Drill MODEL 6501 003002 DOUBLE INSULATION I N S T R U C T I O N M A N U A L WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
More informationNote: Do not bury sulphur dioxide lines Use stainless steel pipe and fittings only where specified on project drawings.
1/7 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Liquid and High Pressure Gaseous Dry Sulphur Dioxide (Less than 100 ppm of water)
More informationHAND HELD SAW W MILL
HAND HELD SAW W MILL 92247 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight Tools. All
More informationRosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS
Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process
More information3/8 Butterfly Air Impact Wrench
3/8 Butterfly Air Impact Wrench 37730 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight
More informationHIGH PERFORMANCE FILTERS FOR COMPRESSED AIR & GAS
HIGH PERFORMANCE FILTERS FOR COMPRESSED AIR & GAS P-2000 SERIES Value and Performance Through Advanced Technology P-2000 SERIES FILTERS VALUE AND PERFORMANCE THROUGH TECHNOLOGY State-of-the-art technologies
More informationGlenco Gas/Liquid Syringes from Spectrum Chromatography
Glenco Gas/Liquid Syringes from Spectrum Chromatography D10122 180296 Copyright 1996 by Spectrum Chromatography PO Box 672026 Houston, TX 77267-2026 Phone: (281) 443-2900 (800) 459-9700 (US & Canada) Fax:
More informationENGLISH (Original instructions) INSTRUCTION MANUAL. Drill MDP303 MDP304 DOUBLE INSULATION. IMPORTANT: Read Before Using.
ENGLISH (Original instructions) INSTRUCTION MANUAL Drill MDP303 MDP304 0876 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model MDP303 MDP304 Capacities
More informationPressure transmitter AKS 32 and AKS 33
Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS
More informationMagnetostrictive Level Transmitter
Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor
More informationInstallation Instructions In-bottom/Out-back Cooling Kit for E3h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302
1.1 Description The in-bottom/out-back cooling kit fits the following E3h drives. It is compatible with drives mounted in Rittal TS8 cabinets with widths of 600 mm (24 in) or 800 mm (32 in). VLT HVAC Drive
More informationCOMPRESSED AIR/GAS FILTERS. MANUFACTURED with high-quality components and innovative engineering
Section 60 ulletin -8 SIGN for economical, trouble-free performance and long-life reliability MNUFTUR with high-quality components and innovative engineering SUPPORT by a world-wide distribution network
More informationPFM 5000 Measuring Instrument
Application Multi branch systems The PFM 5000 is able to calculate complicated multi branch heating systems by simulating the hydraulic system using balancing calculations based on readings in each branch.
More informationThreadlocking Adhesives
Threadlocking Adhesives Locking of Threaded Fasteners Why use a Threadlocker? threadlocking products prevent self-loosening and secure any threaded fastener against vibration and shock loads. They are
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationEXPLODED VIEW OF KINNEY MODELS KC-5 & KC-8
EXPLODED VIEW OF KINNEY MODELS KC-5 & KC-8 KC-5 KC-8 Pump RPM 638 1022 Motor HP (kw) 0.33 (0.25) 0.50 (0.37) Oil Capacity, qts. (liters) 0.8 (0.76) Forced Drain w/ open suction, qts. (liters) 0.85 (0.80)
More informationAsme B31 1 Power Piping Design Standard Certification
ASME B31 1 POWER PIPING DESIGN STANDARD CERTIFICATION PDF - Are you looking for asme b31 1 power piping design standard certification Books? Now, you will be happy that at this time asme b31 1 power piping
More informationAcuteB Head. User s Guide
User s Guide SAFETY PRECAUTIONS! Read and follow all safety instructions below carefully to avoid injuries or damages! Make sure that this user manual always accompanies equipment! Profoto products are
More informationReliance SG777 Series Steel Water Gage Valves
Installation, Operation, & Maintenance Instructions R500.SG777 10/16/2016 Reliance SG777 Series Steel Water Gage Valves Note: Design variations in Steel Water Gage Valves necessitate typical illustrations,
More informationphix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812
PH, TEMPERATURE AND REDOX MEASUREMENT General The advanced and unique design of phix Compact ensures that your work is done fast, easy and with accuracy. The compact design offers a union in one end, and
More informationCheck valve type RK and RB
Check valve type RK and RB Product documentation Screw-in valve Operating pressure pmax: Flow rate Qmax: 700 bar 620 lpm D 7445 02-2017-3.1 by HAWE Hydraulik SE. The reproduction and distribution of this
More informationStudent Sheet. P003S: Making Paint with Minerals
Student Sheet In this practical I will be: Creating egg tempera paints and oil paints from different types of minerals. Evaluating the different paints, looking at various aspects, including: o what colours
More informationWALL MOUNTED POTFILLER INSTALLATION INSTRUCTIONS. Potfiller Model #s:
WALL MOUNTED POTFILLER INSTALLATION INSTRUCTIONS Potfiller Model #s: 3100 3150 3200 3100 3150 3200 BEFORE YOU BEGIN YOUR INSTALLATION: INSTALLATION GUIDE 1 2 3 4 Turn off water supply. Observe all local
More informationPressure Transmitter SIL
Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute
More informationProHead. User s Guide
ProHead User s Guide 2Profoto ProHead Profoto ProHead Thank you for choosing Profoto. Thanks for showing us your confidence by investing in a ProHead unit. For more than four decades we have sought the
More informationUser guide ProHead Plus
User guide ProHead Plus For other languages visit: /support ProHead Plus 2 Congratulations on your new Profoto product! Thanks for showing us your confidence by investing in a ProHead unit. For more than
More informationHandling and Electrical Contacting of Piezoceramic Components
Technical Note Handling and Electrical Contacting of Piezoceramic Components Contents About this Document... 2 Symbols and Typographic Conventions... 2 Safety Instructions... 2 Personnel Qualification...
More informationThe Government of the Republic of Moldova. The Standardization and Metrology Service
The Government of the Republic of Moldova The Standardization and Metrology Service Introduction The convention on the Transboundary Effects of Industrial Accidents was ratified by the parliament decision
More informationDrill MODEL 6013B MODEL 6013BR. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
ENGLISH Drill MODEL 6013B MODEL 6013BR 004618 DOUBLE INSULATION I N S T R U C T I O N M A N U A L WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE
More informationOPTISENS ORP 8590 Technical Datasheet
OPTISENS ORP 8590 Technical Datasheet ORP sensor for water and wastewaster industry Large ceramic diaphragm and integrated Pt100 Special sensor design for all-purpose applications Low maintenance costs
More informationENGLISH (Original instructions) INSTRUCTION MANUAL. Hammer Drill HP1630 HP1631 DOUBLE INSULATION. IMPORTANT: Read Before Using.
ENGLISH (Original instructions) INSTRUCTION MANUAL Hammer Drill HP630 HP63 008892 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model HP630 HP63 Concrete
More information50, 75, & 150 PG PILOT
Repair Manual 50, 75, & 150 PG PILOT 50, 75, & 150 PG PILOT REPAIR MANUAL INDEX Introduction... 1 Elastomer Materials... 2 Disassembly... 3 Part Inspection... 6 Assembly... 7 Testing... 11 NOTE: We reserve
More informationUser guide ProRing. For other languages visit:
User guide ProRing For other languages visit: /support 2 Thank you for choosing Profoto. Follow the instructions in this booklet to use your new product. 3 Thanks for showing us your confidence by investing
More informationProduct Launch Package. Refrigeration Marketing Units Emerson Climate Technologies Europe
Digital Receiver Unit - HLR Product Launch Package Refrigeration Marketing Units Emerson Climate Technologies Europe Emerson Climate Technologies Existing Digital Range Application Outdoor Installations,
More informationMagnetic Inductive Flow Sensor induq
Operating manual (Translation) Operating manual... page 1-16 Magnetic Inductive Flow Sensor induq Series VMZ SIKA Ba_VMZ_en 10/2014. Please keep this operating manual for future reference. If the device
More informationOperating Manual 6 Industrial Bench Grinder ATBG280/
Operating Manual 6 Industrial Bench Grinder ATBG280/6 804531 40 Year Australian Heritage The reputable name in bench grinders for 40 years Protect yourself and others by observing all safety information,
More informationModel ADJUSTABLE ROLLER STAND WITH THREE-LEG SUPPORT
ADJUSTABLE ROLLER STAND WITH THREE-LEG SUPPORT Model 46086 ASSEMBLY and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to
More informationPrecision Split Parts Manual
Precision Split Parts Manual Models 9700 7-Ton Log Splitter 9700 -Ton Log Splitter 086000B /09 Printed in USA THE MANUAL Before you operate your unit, carefully and completely read manuals supplied with
More informationTYPE OF PIPING PRESSURE TESTING. For large diameter piping hand wipe/ sweep should be applied as much as possible (inspection to be recorded).
ATTACHMENT A (1/1) TYPE OF PIPING PRESSURE TESTING TEST TYPE TEST MEDIUMS APPLIED (As per Block Dia.) WORK SEQUENCE HYDROSTATIC Water * For SS/HA piping Max. Cl. 40 ppm General CASE-1 (Base Case) CASE-2
More informationReliance SG800 Series Steel Water Gage Valves
Installation, Operation, & Maintenance Instructions R500.541D1 10/16/2016 Reliance SG800 Series Steel Water Gage Valves Note: Design variations in Steel Water Gage Valves necessitate typical illustrations,
More informationCHROMATOGRAPHY. 1. Place about 5 drops of blue food color in a disposable plastic cup, a small glass container or on a glass or ceramic plate.
Paper chromatography is a modern method used separate mixtures. Paper chromatography uses paper as the stationary phase and a liquid solvent as the mobile phase. You will use paper chromatography to test
More informationENGLISH (Original instructions) INSTRUCTION MANUAL. Drill 6402 DP4700 DP4700 DOUBLE INSULATION. IMPORTANT: Read Before Using.
ENGLISH (Original instructions) INSTRUCTION MANUAL Drill 6402 DP4700 6402 DP4700 00465 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model 6402 DP4700 Capacities
More informationSUBMITTAL INFORMATION "BOLTS, NUTS AND FLAT WASHERS" "ABSTRACT OF ASTM A307 GRADE A AND B" CARBON STEEL BOLTS AND STUDS, 60,000 PSI TENSILE STRENGTH
"BOLTS, NUTS AND FLAT WASHERS" "ABSTRACT OF ASTM A307 GRADE A AND B" CARBON STEEL BOLTS AND STUDS, 60,000 PSI TENSILE STRENGTH GRADE: LOW CARBON STEEL GRADE A GRADE B PHOSPHOROUS MAX % 0.06 0.04 SULFUR,
More informationMUELLER GAS. DH-5/EH-5 Drilling. Reliable Connections. DH-5 Drilling Machine General Information 2. EH-5 Drilling Machine General Information 3
operating Instructions manual MUELLER GAS TAble of contents PAGE DH-5 Drilling Machine General Information 2 DH-5/EH-5 Drilling EH-5 Drilling Machine General Information 3 Operating Instructions 4-5 DH-5
More informationSight glass window Sight flow indicator
SIGHT GLASS Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels. When it comes to selecting a sight glass, a wide variety of factors should be considered
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationTransparent Glass Colours Firing Range: C
1/5 General Information There is a wide range of applications for Transparent glass colours. Where high chemical resistance is not requested, the colours can be applied. They are used for the decorating
More informationImpact Wrench MODEL 6905B MODEL 6906
ENGLISH Impact Wrench MODEL 6905B MODEL 6906 005305 DOUBLE INSULATION I N S T R U C T I O N M A N U A L WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR
More informationTUpH 396RVP and 398RVP Retractable ph/orp Sensors
Instruction Sheet TUpH Sensors LIQ_MAN_ABR_396RVP-398RVP September 2013 TUpH 396RVP and 398RVP Retractable ph/orp Sensors Specifications SPECIFICATIONS 396RVP 398RVP Measurements and Ranges ph: 0-14; ORP:
More informationOPTISENS PH 8390 Technical Datasheet
OPTISENS PH 8390 Technical Datasheet ph sensor for water and wastewater industry Large PTFE diaphragm and integrated Pt100 Robust sensor design for harsh applications Low maintenance costs and a long life
More informationHEADING DESCRIPTION OF GOODS RATE OF DUTY
32.01 Tanning extracts of vegetable origin; tannins and their salts, ethers, esters and other derivatives. 3201.10.00 Quebracho extract Free kg 3201.20.00 Wattle extract Free kg 3201.90.00 Other Free kg
More informationInstruction Manual. Self-Leveling Cross-Line Laser Level Model No and
3728H_Manuals 9/2/10 8:02 AM Page 1 Self-Leveling Cross-Line Laser Level Model No. 40-6620 and 40-6625 Instruction Manual Congratulations on your choice of this Self-Leveling Cross-Line Laser Level. We
More informationJIP JIP Hot Hot Tapping Machine DN
JIP JIP Hot Hot Tapping Machine DN 20-100 Danfoss 2017.06 VI.KD.G1.02 1 1. Content Page 1. Content 2 2. Safety Instructions 3 2.1 General Safety Requirements 3 2.2 Safety Requirements at the Workside 4
More informationHandling instructions
Orbital Sander Model SV 12SG Handling instructions Note: Before using this Electric Power Tool, carefully read through these HANDLING INSTRUCTIONS to ensure efficient, safe operation. It is recommended
More informationC-15 Truck Engine 9NZ00001-UP(SEBP ) - Document Structure. Media Number -RENR Publication Date -01/07/2008 Date Updated -22/07/2008
Page 1 of 8 Shutdown SIS Previous Screen Product: TRUCK ENGINE Model: C-15 TRUCK ENGINE 9NZ Configuration: C-15 Truck Engine 9NZ00001-UP Disassembly and Assembly C-15, C-16 and C-18 Truck Engines Media
More informationENGLISH (Original instructions) INSTRUCTION MANUAL. Hammer Drill MHP161 DOUBLE INSULATION. IMPORTANT: Read Before Using.
ENGLISH (Original instructions) INSTRUCTION MANUAL Hammer Drill MHP6 0088 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model MHP6 Concrete 6 mm Capacities
More informationLEVEL Switches RFM-500 RAM-403 RRH-300 RLH-300 RNM-401
Vibrating fork level switches nivoswitch GENERL DESCRITION NIVOSWITCH vibrating fork level switches are suitable for level detection of liquids or granular, powdered solids. Units with parallel vibrating
More informationROLLER STAND WITH TWO-LEG SUPPORT ASSEMBLY AND OPERATING INSTRUCTIONS
ROLLER STAND WITH TWO-LEG SUPPORT 95621 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2006 by Harbor Freight
More informationAngle Grinder MODEL 9553B MODEL 9555B
ENGLISH Angle Grinder MODEL 9553B MODEL 9555B 006649 DOUBLE INSULATION I N S T R U C T I O N M A N U A L WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR
More informationTechnical Information 16.P.006 Conventional Offset Systems Ink Series, Process Inks
Technical Information 16.P.006 Conventional Offset Systems Ink Series, Process Inks MGA NATURA Extended Colour Gamut Series Extended Colour Gamut 7-colour ink series to enable printing of a wider number
More informationLPK1550 Hydraulic Crimping Tool 15-ton
SERVICE MANUAL LPK1550 Hydraulic Crimping Tool 15-ton Serial Code FYF Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register
More informationAngle Drill MODEL DA3000R MODEL DA3000V
ENGLISH Angle Drill MODEL DA3000R MODEL DA3000V 003004 DOUBLE INSULATION I N S T R U C T I O N M A N U A L WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR
More information21 PC PAINT SPRAY GUN KIT Model 90985
21 PC PAINT SPRAY GUN KIT Model 90985 ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2003 by Harbor Freight
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationIntrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751
Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable
More informationTB404 Conductivity sensors. Perfect for use in standard to highly corrosive solutions
Data sheet TB404 Conductivity sensors Toroidal Perfect for use in standard to highly corrosive solutions Greatly reduces coating and other fouling problems Inductive measurement technique yields a solution
More informationENGLISH (Original instructions) INSTRUCTION MANUAL. Finishing Sander BO4553 BO4561 BO4563 DOUBLE INSULATION. IMPORTANT: Read Before Using.
ENGLISH (Original instructions) INSTRUCTION MANUAL Finishing Sander BO4553 BO456 BO4563 00449 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model BO4553
More informationINSTRUCTION MANUAL PLD5020A. PLD5020A 100W Paint Sprayer
INSTRUCTION MANUAL PLD5020A PLD5020A 100W Paint Sprayer Specifications Voltage: Rated Power: Reservoir Capacity: Operating Pressure: Flow Rate: Viscosity: Nozzle: Weight: 230-240 Vac 100W 700 ml 140 Bar
More informationENGLISH (Original instructions) INSTRUCTION MANUAL. Curved Planer 1002BA DOUBLE INSULATION. IMPORTANT: Read Before Using.
ENGLISH (Original instructions) INSTRUCTION MANUAL Curved Planer 00BA 0059 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model 00BA Planing width 0 mm Planing
More informationC6 Corvette Rear Spoiler Kit CDC #
2005 2008 C6 Corvette Rear Spoiler Kit CDC # 0542 7002 01 Note: Read installation instructions before starting Kit Includes: 1 C6 Rear Spoiler 2 CHMSL Bracket # 0542-3500-01 2 Screw 4.2 x 1.41 x 25 # 30005
More informationFraming Table INSTRUCTIONAL MANUAL KFT4X8. 5/2018 CT6071 Rev D
Framing Table INSTRUCTIONAL MANUAL KFT4X8 5/2018 CT6071 Rev D 1. Table of Contents Thank you for your purchase! Kreg Tool Company is proud to manufacture top quality machines that are surpassed only by
More informationOperating Manual Riveting Tool R1. For installing blind rivet nuts
L Operating Manual Riveting Tool R1 For installing blind rivet nuts Table of contents 1. Introduction 1.1 General instructions... 2 1.2 Description of the riveting tool... 3 1.3 Safety instructions...
More informationThis specification describes the minimum requirements for piping systems for the following service:
SPEC-3501 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Instrument Air Design Conditions 150 PSIG @ 180 F Operating Conditions 125
More information3 POINT HITCH LOGSPLITTER
3 POINT HITCH LOGSPLITTER OPERATOR S MANUAL AND PARTS LIST TABLE OF CONTENTS SECTION PAGE 1. GENERAL INFORMATION 1 2. SAFETY GUIDELINES 2 2.1 DEFINITIONS 2 2.2 SAFE OPERATING PROCEDURE 3 3. LOG SPLITTER
More informationSarasota CM200 Sarasota HME900 Density Converter Electronics
Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or
More information