Slope Floor. Measurement Methods

Size: px
Start display at page:

Download "Slope Floor. Measurement Methods"

Transcription

1 Slope Floor Measurement Methods Many chair installations are on sloped floors. Hussey Seating uses five different feet for floor mount chairs based on the degree of slope. The slope of the floor is a critical element to ensure a successful installation. There are two methods to measure this factor. Hussey Seating recommends the use of a SmartLevel. SmartLevel: This is a level which can be placed directly on the floor and produce a digital readout of the degree of slope. (These can be purchased at a local hardware store.) The traditional method of measuring the floor slope requires the use of a standard level and tape measure. Using the level, bring it to a level position. Measure the dimension from the floor to the outward end, bottom side of the level. You must also provide the length of the level you are using. (Example: using a 24" level with a dimension of 3" from the floor to the level is 3" in 24".) It is critical that a measurement be taken at each break in the floor. Therefore a 3" rise over a 24" run = 1 1/2" slope per foot. There are some limitations to the slope for Hussey chairs. The maximum slope is 1 1/2" in 12". Additionally, there are some restrictions placed by the American Disabilities Act. The maximum floor slope is 1" in 12". The maximum length of a sloped floor cannot exceed 30 after which there must be a level run of 5.

2 Chair Ordering Instructions CHAIR ORDERING: The accompanying chart has been designed to assist in determining the quantity and sizes of chairs to order and the quantity and type of standards to order. The procedures used with this chart are dependent on the accuracy of the field check and the use of the Chair Size Chart. PROCEDURES: 1. Focus on one section of seating at a time. If it is a straight section, measure the first and last rows to determine if the dimension changes. (If it is a tapered section, it is critical to measure each row to calculate the quantities.) 2. Log on the chart which section you are measuring and the number of rows. Using the Chair Size Chart find the corresponding dimension of the row length and identify the quantity and sizes of the chairs. Enter this data on the chart. 4. To determine the quantity of intermediate standards for each row, use the number of chairs per row minus one. Add one left end standard per row and one right end standard per row (unless special situation). Enter these quantities on the chart. 5. Total the number of left, intermediate and right standards per section and enter on the chart. 6. Repeat these steps for each section of seating. 3. Calculate the total quantity by size for the entire section and enter on chart.

3 Chair Ordering Chart U.S. Chair Sizes & Units Chair Ordering Chart CHAIR SIZES PER ROW CHAIR SIZES PER SECTION STANDARDS PER ROW STANDARDS PER SECTION Section #Rows Length #Chairs 19" 20" 21" 22" 24" 19" 20" 21" 22" 23" 24" Left Interm. Right Left Interm. Right A EXAMPLE: 13 21'-6" Totals: Key: Section: Reference seating section Chair Sizes per section: Chair Sizes per row x the number of rows #Rows: Number of rows per section Standards per row: 1 left & 1 right; intermediate = # chairs in a row minus 1 Length: Dimensions of actual row length (feet) Standards per section: Standards per row x number of rows #Chairs: Reference Chair Sizing Chart Dimensions are in feet and inches. 09/02

4 Chair Ordering Chart Metric Chair Sizes & Units Chair Ordering Chart CHAIR SIZES PER ROW CHAIR SIZES PER SECTION STANDARDS PER ROW STANDARDS PER SECTION Section #Rows Length #Chairs Left Interm. Right Left Interm. Right A EXAMPLE: 13 21'-6" Totals: Key: Section: Reference seating section Chair Sizes per section: Chair Sizes per row x the number of rows #Rows: Number of rows per section Standards per row: 1 left & 1 right; intermediate = # chairs in a row minus 1 Length: Dimensions of actual row length (feet) Standards per section: Standards per row x number of rows #Chairs: Reference Chair Sizing Chart Chair Sizes are in millimeters Row length is in meters

5 Chair Sizing Chart Instructions Chair Sizing: This chart assists in determining the chair sizes needed in a seating arrangement. The dimension for end spaces has been factored into these calculations. However, the following chart will provide these dimensions. CHAIR SERIES Quattro Floor Mount Quattro Riser Mount END DIMENSION 2" [51mm] 3" [76mm] To use the Chair Size Chart, follow these procedures: 1. Determine the space available for each row. The chart automatically calculates a 2" spacing at each end of the row for floor mounted chairs. If you require 3" end spacing for riser mounted chairs, you must factor in the difference. NOTE: Reference applicable building code to determine the maximum number of seats allowed in a row. 2. Read down the column marked feet and then across the top marked inches and find the appropriate dimension. 3. Select the chair sizes from the suggested combinations. 4. Staggered seating may be achieved by using varying chair size combinations in alternate rows.

6 Chair Sizing Chart Maximizing Seat Count Maximizing Seat Count INCHES (Determined row length) Feet 0" 1" 2" 3" 4" 5" 6" 7" 8" 9" 10" 11" Feet 1 1@ @20 1@21 1@ @19 1@19 & 1@20 2@20 1@20 & 1@21 2@21 1@21 & 1@ @ @19 2@19 & 1@20 1@19 & 2@20 3@20 2@20 & 1@21 1@20 & 2@21 3@21 2@21 & 1@22 1@21 & 2@22 3@ @19 3@19 & 1@20 2@19 & 2@20 1@19 & 3@ @20 3@20 & 1@21 1@20 & 3@21 4@21 3@21 & 2@22 3@21 & 1@22 2@21 & 2@22 1@21 & 3@22 4@ @19 4@19 & 1@20 3@19 & 2@20 2@19 & 3@20 1@19 & 4@20 5@20 4@20 & 1@21 3@20 & 2@21 2@20 & 3@ @20 & 4@21 5@21 4@21 & 1@22 3@21 & 2@22 2@21 & 3@22 1@21 & 4@22 5@22 6@19 5@19 & 1@ @19 & 2@20 3@19 & 3@20 2@19 & 4@20 1@19 & 5@20 6@20 5@20 & 1@21 4@20 & 2@21 3@20 & 3@21 2@20 & 4@21 1@20 & 5@21 6@21 5@21 & 1@ @21 & 2@22 3@21 & 3@22 2@21 & 4@22 1@21 & 5@22 6@22 7@19 6@19 & 1@20 5@19 & 2@20 4@19 & 3@20 3@19 & 4@20 2@19 & 5@20 1@19 & 6@ @20 6@20 & 1@21 5@20 & 2@21 4@20 & 3@21 3@20 & 4@21 2@20 & 5@21 1@20 & 6@21 7@21 6@21 & 1@22 5@21 & 2@22 4@21 & 3@22 3@21 & 4@ @19 7@19 & 1@20 6@19 & 2@20 5@19 & 3@20 4@19 & 4@20 3@19 & 5@20 2@19 & 6@20 1@19 & 7@20 8@20 7@20 & 1@21 6@20 & 2@21 5@20 & 3@ @20 & 4@21 3@20 & 5@21 2@20 & 6@21 1@20 & 7@21 8@21 7@21 & 1@22 6@21 & 2@22 9@19 8@19 & 1@20 7@19 & 2@20 6@19 & 3@20 5@19 & 4@ @19 & 5@20 3@19 & 6@20 2@19 & 7@20 1@19 & 8@20 9@20 8@20 & 1@21 7@20 & 2@21 6@20 & 3@21 5@20 & 4@21 4@20 & 5@21 3@20 & 6@21 2@20 & 7@ @20 & 8@21 9@21 10@19 9@19 & 1@20 8@19 & 2@20 7@19 & 3@20 6@19 & 4@20 5@19 & 5@20 4@19 & 6@20 3@19 & 7@20 2@19 & 8@20 1@19 & 9@ @20 9@20 & 1@21 8@20 & 2@21 7@20 & 3@21 6@20 & 4@21 5@20 & 5@21 4@20 & 6@21 3@20 & 7@21 2@20 & 8@21 11@19 10@19 & 1@20 9@19 & 2@ @19 & 3@20 7@19 & 4@20 6@19 & 5@20 5@19 & 6@20 4@19 & 7@20 3@19 & 8@20 2@19 & 9@20 1@19 & 10@20 11@20 10@20 9@20 & 2@21 8@20 & 3@ @20 & 4@21 6@20 & 5@21 5@20 & 6@21 4@20 & 7@21 12@19 11@19 & 1@20 10@19 & 2@20 9@19 & 3@20 8@19 & 4@20 7@19 & 5@20 6@19 & 6@20 5@19 & 7@ @19 & 8@20 3@19 & 9@20 2@19 & 10@20 1@19 & 11@20 12@20 11@20 & 1@21 10@20 & 2@21 9@20 & 3@21 8@20 & 4@21 7@20 & 5@21 6@20 & 6@21 13@ @19 & 1@20 11@19 & 2@20 10@19 & 3@20 9@19 & 4@20 8@19 & 5@20 7@19 & 6@20 6@19 & 7@20 5@19 & 8@20 4@19 & 9@20 3@19 & 10@20 2@19 & 11@20 1@19 & 12@ @20 12@20 & 1@21 11@20 & 2@21 10@20 & 3@21 9@20& 4@21 8@20 & 5@21 14@19 13@19 & 1@20 12@19 & 2@20 11@19 & 3@20 10@19 & 4@20 9@19 & 5@ @19 & 6@20 7@19 & 7@20 6@19 & 8@20 5@19 & 9@20 4@19 & 10@20 3@19 & 11@20 2@19 & 12@20 1@19 & 13@20 14@20 13@20 & 1@21 12@20 & 2@21 11@20 & 3@ @20 & 4@21 15@19 14@19 & 1@20 13@19 & 2@20 12@19 & 3@20 11@19 & 4@20 10@19 & 5@20 9@19 & 6@20 8@19 & 7@20 7@19 & 8@20 6@19 & 9@20 5@19 & 10@ @19 & 11@20 3@19 & 12@20 2@19 & 13@20 1@19 & 14@20 15@20 14@20 & 1@21 13@20 & 2@21 12@20 & 3@21 16@19 15@19 & 1@20 14@19 & 2@20 13@19 & 3@ @19 & 4@20 11@19 & 5@20 10@19 & 6@20 9@19 & 7@20 8@19 & 8@20 7@19 & 9@20 6@19 & 10@20 5@19 & 11@20 4@19 & 12@20 3@19 & 13@20 2@19 & 14@20 1@19 & 15@ @20 15@20 & 1@21 14@20 & 2@21 17@19 16@19 & 1@20 15@19 & 2@20 14@19 & 3@20 13@19 & 4@20 12@19 & 5@20 11@19 & 6@20 10@19 & 7@20 9@19 & 8@ @19 & 9@20 7@19 & 10@20 6@19 & 11@20 5@19 & 12@20 4@19 & 13@20 3@19 & 14@20 2@19 & 15@20 1@19 & 16@20 17@20 16@20 & 1@21 15@20 & 2@21 17@19 & 1@20 28

7 Chair Sizing Chart Maximizing Seat Size Maximizing Seat Size INCHES (Determined row length) 0" 1" 2" 3" 4" 5" 6" 7" 8" 9" 10" 11" Feet @23 1@ @23 1@23 & 1@24 2@ @23 2@23 & 1@24 1@23 & 2@24 3@ @23 3@23 & 1@24 2@23 & 2@24 1@23 & 3@24 4@ @ @23 & 1@24 3@23 & 2@24 2@23 & 3@24 1@23 & 4@24 5@ @23 5@23 & 1@ @23 & 2@24 3@23 & 3@24 2@23 & 4@24 1@23 & 5@24 6@ @23 6@23 & 1@24 5@23 & 2@ @23 & 3@24 3@23 & 4@24 2@23 & 5@24 1@23 & 6@24 7@ @23 7@23 & 1@24 6@23 & 2@24 5@23 & 3@ @23 & 4@24 3@23 & 5@24 2@23 & 6@24 1@23 & 7@24 8@ @23 8@23 & 1@24 7@23 & 2@24 6@23 & 3@24 5@23 & 4@ @23 & 5@24 3@23 & 6@24 2@23 & 7@24 1@23 & 8@24 9@ @23 9@23 & 1@24 8@23 & 2@24 7@23 & 3@24 6@23 & 4@24 5@23 & 5@ @23 & 6@24 3@23 & 7@24 2@23 & 8@24 1@23 & 9@24 10@ @23 10@23 & 1@24 9@23 & 2@24 8@23 & 3@24 7@23 & 4@24 6@23 & 5@24 5@23 & 6@ @23 & 7@24 3@23 & 8@24 2@23 & 9@24 1@23 & 10@24 11@ @23 11@23 & 1@24 10@23 & 2@24 9@23 & 3@24 8@23 & 4@24 7@23 & 5@24 6@23 & 6@24 5@23 & 7@ @23 & 8@24 3@23 & 9@24 2@23 & 10@24 1@23 & 11@24 12@ @23 12@23 & 1@24 11@23 & 2@24 10@23 & 3@24 9@23 & 4@24 8@23 & 5@24 7@23 & 6@24 6@23 & 7@24 5@23 & 8@ @23 & 9@24 3@23 & 10@24 2@23 & 11@24 1@23 & 12@24 13@ @23 13@23 & 1@24 12@23 & 2@24 11@23 & 3@24 10@23 & 4@24 9@23 & 5@24 8@23 & 6@24 7@23 & 7@24 6@23 & 8@24 5@23 & 9@ @23 & 10@24 3@23 & 11@24 2@23 & 12@24 1@23 & 13@24 14@ @23 14@23 & 1@24 13@23 & 2@24 12@23 & 3@24 11@23 & 4@24 10@23 & 5@24 9@23 & 6@24 8@23 & 7@24 7@23 & 8@24 6@23 & 9@24 5@23 & 10@24 29

8 Row Length Chart US Note: Dim. A = 2" (51mm) floor mount Dim. A = 3" (76mm) riser mount = Centerline Example: (3) 20" Quattro floor mount chairs = 5'-4" row length. DIMENSIONS: Center line to Center line (feet) QTY CHAIR SIZE QTY CHAIR SIZE 19" 20" 21" 22" 23" 24" 19" 20" 21" 22" 23" 24" 2 3'-2 3'-4 3'-6 3'-8 3'-10 4' '-8 53'-4 56'-0 58'-8 61'-4 64'-0 3 4'-9 5'-0 5'-3 5'-6 5'-9 6' '-3 55'-0 57'-9 60'-6 63'-3 66'-0 4 6'-4 6'-8 7'-0 7'-4 7'-8 8' '-10 56'-8 59'-6 62'-4 65'-2 68'-0 5 7'-11 8'-4 8'-9 9'-2 9'-7 10' '-5 58'-4 61'-3 64'-2 67'-1 70'-0 6 9'-6 10'-0 10'-6 11'-0 11'-6 12' '-0 60'-0 63'-0 66'-0 69'-0 72' '-1 11'-8 12'-3 12'-10 13'-5 14' '-7 61'-8 64'-9 67'-10 70'-11 74' '-8 13'-4 14'-0 14'-8 15'-4 16' '-2 63'-4 66'-6 69'-8 72'-10 76' '-3 15'-0 15'-9 16'-6 17'-3 18' '-9 65'-0 68'-3 71'-6 74'-9 78' '-10 16'-8 17'-6 18'-4 19'-2 20' '-4 66'-8 70'-0 73'-4 76'-8 80' '-5 18'-4 19'-3 20'-2 21'-1 22' '-11 68'-4 71'-9 75'-2 78'-7 82' '-0 20'-0 21'-0 22'-0 23'-0 24' '-6 70'-0 73'-6 77'-0 80'-6 84' '-7 21'-8 22'-9 23'-10 24'-11 26' '-1 71'-8 75'-3 78'-10 82'-5 86' '-2 23'-4 24'-6 25'-8 26'-10 28' '-8 73'-4 77'-0 80'-8 84'-4 88' '-9 25'-0 26'-3 27'-6 28'-9 30' '-3 75'-0 78'-9 82'-6 86'-3 90' '-4 26'-8 28'-0 29'-4 30'-8 32' '-10 76'-8 80'-6 84'-4 88'-2 92' '-11 28'-4 29'-9 31'-2 32'-7 34' '-5 78'-4 82'-3 86'-2 90'-1 94' '-6 30'-0 31'-6 33'-0 34'-6 36' '-0 80'-0 84'-0 88'-0 92'-0 96' '-1 31'-8 33'-3 34'-10 36'-5 38' '-7 81'-8 85'-9 89'-10 93'-11 98' '-8 33'-4 35'-0 36'-8 38'-4 40' '-2 83'-4 87'-6 91'-8 95' ' '-3 35'-0 36'-9 38'-6 40'-3 42' '-9 85'-0 89'-3 93'-6 97'-9 102' '-10 36'-8 38'-6 40'-4 42'-2 44' '-4 86'-8 91'-0 95'-4 99'-8 104' '-5 38'-4 40'-3 42'-2 44'-1 46' '-11 88'-4 92'-9 97'-2 101'-7 106' '-0 40'-0 42'-0 44'-0 46'-0 48' '-6 90'-0 94'-6 99'-0 103'-6 108' '-7 41'-8 43'-9 45'-10 47'-11 50' '-1 91'-8 96'-3 100' '-5 110' '-2 43'-4 45'-6 47'-8 49'-10 52' '-8 93'-4 98'-0 102'-8 107'-4 112' '-9 45'-0 47'-3 49'-6 51'-9 54' '-3 95'-0 99'-9 104'-6 109'-3 114' '-4 46'-8 49'-0 51'-4 53'-8 56' '-10 96'-8 101'-6 106'-4 111'-2 116' '-11 48'-4 50'-9 53'-2 55'-7 58' '-5 98'-4 103'-3 108'-2 113'-1 118' '-6 50'-0 52'-6 55'-0 57'-6 60' '-0 100'-0 105'-0 110'-0 115'-0 120' '-1 51'-8 54'-3 56'-10 59'-5 62'-0

9 Row Length Chart Metric Note: Dim. A = 2" (51mm) floor mount Dim. A = 3" (76mm) riser mount = Centerline Example: (3) 500mm Quattro floor mount chairs m row length. DIMENSIONS: Center line to Center line (meters) QTY CHAIR SIZE QTY CHAIR SIZE 500 mm 525 mm 550 mm 575 mm 600 mm 500 mm 525 mm 550 mm 575 mm 600 mm

10 Row Spacing Chart US *Notes: 1. Refer to applicable building codes. 2. Spacing varies with tablet arm applications. Consult Hussey Engineers for details. 3. Row space dimension will be the sum of clear space (see building codes) plus chair envelope (see chair dimensions) plus any additional space as desired for convenience to permit patron easy access to concessions, rest rooms, etc. Number of Seating Rows (spacing + 1) OVERALL SPACING OF CHAIRS (back to back, measured in feet) ROW SPACE DIMENSIONS '-8 2'-9 2'-10 2'-11 3'-0 3'-1 3'-2 3'-3 3'-4 3'-5 3'-6 3 5'-4 5'-6 5'-8 5'-10 6'-0 6'-2 6'-4 6'-6 6'-8 6'-10 7'-0 4 8'-0 8'-3 8'-6 8'-9 9'-0 9'-3 9'-6 9'-9 10'-0 10'-3 10' '-8 11'-0 11'-4 11'-8 12'-0 12'-4 12'-8 13'-0 13'-4 13'-8 14' '-4 13'-9 14'-2 14'-7 15'-0 15'-5 15'-10 16'-3 16'-8 17'-1 17' '-0 16'-6 17'-0 17'-6 18'-0 18'-6 19'-0 19'-6 20'-0 20'-6 21' '-8 19'-3 19'-10 20'-5 21'-0 21'-7 22'-2 22'-9 23'-4 23'-11 24' '-4 22'-0 22'-8 23'-4 24'-0 24'-8 25'-4 26'-0 26'-8 27'-4 28' '-0 24'-9 25'-6 26'-3 27'-0 27'-9 28'-6 29'-3 30'-0 30'-9 31' '-8 27'-6 28'-4 29'-2 30'-0 30'-10 31'-8 32'-6 33'-4 34'-2 35' '-4 30'-3 31'-2 32'-1 33'-0 33'-11 34'-10 35'-9 36'-8 37'-7 38' '-0 33'-0 34'-0 35'-0 36'-0 37'-0 38'-0 39'-0 40'-0 41'-0 42' '-8 35'-9 36'-10 37'-11 39'-0 40'-1 41'-2 42'-3 43'-4 44'-5 45' '-4 38'-6 39'-8 40'-10 42'-0 43'-2 44'-4 45'-6 46'-8 47'-10 49' '-0 41'-3 42'-6 43'-9 45'-0 46'-3 47'-6 48'-9 50'-0 51'-3 52' '-8 44'-0 45'-4 46'-8 48'-0 49'-4 50'-8 52'-0 53'-4 54'-8 56' '-4 46'-9 48'-2 49'-7 51'-0 52'-5 53'-10 55'-3 56'-8 58'-1 59' '-0 49'-6 51'-0 52'-6 54'-0 55'-6 57'-0 58'-6 60'-0 61'-6 63' '-8 52'-3 53'-10 55'-5 57'-0 58'-7 60'-2 61'-9 63'-4 64'-11 66' '-4 55'-0 56'-8 58'-4 60'-0 61'-8 63'-4 65'-0 66'-8 68'-4 70' '-0 57'-9 59'-6 61'-3 63'-0 64'-9 66'-6 68'-3 70'-0 71'-9 73' '-8 60'-6 62'-4 64'-2 66'-0 67'-10 69'-8 71'-6 73'-4 75'-2 77' '-4 63'-3 65'-2 67'-1 69'-0 70'-11 72'-10 74'-9 76'-8 78'-7 80' '-0 66'-0 68'-0 70'-0 72'-0 74'-0 76'-0 78'-0 80'-0 82'-0 84' '-8 68'-9 70'-10 72'-11 75'-0 77'-1 79'-2 81'-3 83'-4 85'-5 87' '-4 71'-6 73'-8 75'-10 78'-0 80'-2 82'-4 84'-6 86'-8 88'-10 91' '-0 74'-3 76'-6 78'-9 81'-0 83'-3 85'-6 87'-9 90'-0 92'-3 94' '-8 77'-0 79'-4 81'-8 84'-0 86'-4 88'-8 91'-0 93'-4 95'-8 98' '-4 79'-9 82'-2 84'-7 87'-0 89'-5 91'-10 94'-3 96'-8 99'-1 101' '-0 82'-6 85'-0 87'-6 90'-0 92'-6 95'-0 97'-6 100'-0 102'-6 105'-0

11 Row Spacing Chart Metric *Notes: 1. Refer to applicable building codes. 2. Spacing varies with tablet arm applications. Consult Hussey Engineers for details. 3. Row space dimension will be the sum of clear space (see building codes) plus chair envelope (see chair dimensions) plus any additional space as desired for convenience to permit patron easy access to concessions, rest rooms, etc. OVERALL SPACING OF CHAIRS (back to back measured in meters) Number of Seating Rows (spacing + 1) ROW SPACE DIMENSIONS 825 mm 850 mm 875 mm 900 mm 925 mm 950 mm 975 mm 1000mm

12 Field Check The success of a job is often a direct result of the care taken during a field check. The profitability, ease of installation, and lack of surprises are frequently attributed to the detail and accuracy of the field dimensions. We have provided a checklist of the critical dimensions and measurements and provided a drawing for your reference. Dimension from front wall to back wall (and any changes in the wall structure) A Dimension from side wall to side wall B Dimension from back wall to any obstruction C Obstruction Detail D Door/exit locations J Aisle locations K Dimension from stage to front row of seating L Radius dimensions W Location of Slope changes X Riser dimensions and detail Y Stage or event elevation Z (Please note if the dimensions are taken from a finished wall or an unfinished wall.) IV:1

13 Field Check Drawing "J" "J" "J" "J" "Y " "Y " "Y " "Y " "W" "W" "W" "W" "B" "W"

14 Field Check "Y" "Y" "Y" "Y" "Y " "Y " "Y "

15 Products for Construction & Expansion Joints Construction and Expansion Joints: The size and placement of Construction and Expansion Joints are critical components to the design and cost of a seating installation. The following descriptions of these joints are taken from The Architectural Graphics Standard. Expansion (Isolation) Joints: These allow movement between the concrete slabs and fixed parts of the building such as columns or walls. These types of joints cannot be spanned with chairs mounted to plates, therefore the rows must be broken. Construction Joints: These joints provide stopping places during the floor construction. These types of joints can be spanned with chairs mounted to plates, resulting in a continuous row of chairs. These elements must be taken into consideration in order to have a successful seating layout. Each of these joints has a significant impact on the particular cost and design for installation. Horizontal Construction Joints: These joints are in the concrete riser and are a concern with riser mount chairs. The concrete is usually pre-cast (but not always). The location of the joint or the height of the riser from the deck to the joint, are the critical dimensions. When working on a job with this type of joint, the riser height and the location of rebar, have cost implications. Special anchors may be required. Hussey Seating recommends locating all horizontal joints at the very bottom of the riser. This typically offers the best location to avoid the added cost of offset plates. Hussey Seating uses an offset plate to anchor the chairs without altering the seating plan. The plate offsets the anchors enough to clear the joint. Typically if one chair is offset, all chairs in that row will be offset. Vertical Construction Joints: There are several options available to accommodate joints that span a deck of seating. The most cost effective method is with a carrier plate. Usually only one chair is affected by this anchoring method. This permits movement of the building without damaging the chairs.

16 Corner Angles Corner angles present difficult challenges to architects and owners who want to have continuous rows of chairs, wrapping around the corners. Angles up to 3 require no special mounting requirements. Angles between 3 and 15 can be accommodated with plates and or shims, depending on specific scenario. Our solution to these scenarios will allow chairs to transition smoothly around shallow angle corners providing a more pleasing seating configuration. All corners 18 and greater will require the row of chairs to be split at or near the joint. Hussey Seating offers two solutions for corner angles greater then 18. Option one would be to split the row at the corner joint. When this option is utilized, a large enough gap must be created to accommodate the patron s legs. The second option would be to mount an individual chair directly in the corner and split the row on either side. This option typically minimizes the corner gap and provides a better seating solution.

17 Floor and Riser Design Requirements/Guidelines GENERAL DESIGN NOTES: All floor, slabs and risers constructed of concrete (pre-cast or poured) must meet the following criteria: Floor / Slab must be 4"(10) thick with the top 2"(5cm) clear of any obstructions. (Rebar, meshing, etc.) Riser must be 4½" (11cm) thick minimum with the first 2½" (6cm) along the face clear of any obstructions. (Rebar, meshing, etc.) All concrete must have a minimum strength of 3,000 psi or 20,684 Mpa for proper anchor attachment. Light weight concrete must have a minimum strength of 5,000 psi or 34,475 Mpa. All anchors are supplied by unless otherwise noted. If anchors are to be supplied by someone other than, notification must be made during the submittal process. Hardware Requirements: Concrete Floors: 1/4-20 UNC X 3" expansion anchors with lock washers and flat washers per Hussey Specification. (2 required per foot) Concrete Riser: 3/8-16 UNC X 3½" expansion anchor with lock washers and flat washers per Hussey Specification. (2 required per foot) All floors constructed of wood must be 1½" (3cm) thick minimum. All floor, treads, or risers constructed of steel must meet the following criteria: Minimum steel thickness of 1/4" (6.4mm) Maximum steel thickness of 3/8" (9.5mm) Steel must have minimum tensile strength of 36,000 psi

18 Sightline Formula Principle of Visibility Line of Clear View for Spectator on Tiered Seating: Angle A: Angle of Perfect visibility; looking over all heads. Angle B: Angle of Good visibility; shifting position to look between heads on the row immediately in front of the spectator and over all heads. Angle C: Angle of Fair visibility; shifting position to look between the heads of two rows immediately in front of the spectators and over all other heads. Definition: The lower angle of angle C is approximately 5" (13) above the eyes of the spectators in the third row in front of the spectators. This angle C is called the angle of clear view. The tangent of the angle of clear view = 3R- 5"[13cm] / 3D, where R is the rise and D is the depth per row (row spacing). Head Level from the Floor 4'1" (124) Eye Level from the Floor 3'8" (112) Application: The final analysis being the perpendicular dimension from the court line or the line of play to where the angle of clear view intersects (focal point) should be as small as possible.

19 Principle of Visibility Angle B is commonly used in determining floor slope for auditorium, performing arts or theatre type seating configurations. When angle B profile is used in conjunction with staggered seating arrangement (chair staggered or alternated in arrangements of sizes opposite every other row) it allows unobstructed view of spectators to a determined focal point at the screen or stage. The final analysis is to have all sight lines intersect at the desired focal point. Angle C is most commonly used in determining riser or stepped applications for gymnasiums, arena or stadium type seating configurations. When angle B profile is used (generally associated with an aligned seating arrangement) it allows for unobstructed view of spectators to a determined focal point at court line or line of play. The final analysis is to have all the critical sightlines intersect the focal point or line of play at generally a maximum elevation of 4' (122). TM

20 Sightline Dimensions & Calculations 4'1" (124) = Top of head above seat (chair seating) 3'8" (112) = Eye level above deck (chair seating) Step 1: Solve for angle C, angle of clear view. Tan Angle C = (3 x Rise) - 5" (13cm) / 3 x Tread

21 Sightline Dimensions & Calculations Step 2: Solve for Distance A Using Trig function: Tangent = Opposite/Adjacent Tangent of Angle C = Distance D / Distance A Distance A = Distance D / Tan Angle A Step 3: Solve for Distance B Distance B = Distance A - Distance C Step 4: Solve for Distance E Using Trig function: Tangent = Opposite / Adjacent Tangent of Angle C = Distance E / Distance B Distance E = Tangent of Angle C x Distance B

installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty

installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty Installation Instructions As with any building project, use proper

More information

Construction Tolerances - The following tolerances apply to cast-in-place structures:

Construction Tolerances - The following tolerances apply to cast-in-place structures: 00540.40(b) Construction 00540.40 Tolerances - The following tolerances apply to cast-in-place structures: (a) Foundation Footings: (1) Lateral Alignment: Actual (as cast) location of the center of gravity:

More information

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013 U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS TOOL LIST Required Tools: - Reciprocating Saw with Metal Cutting Blade - Drill - 7/16 Drill Bit for Metal Drilling -

More information

OLYMPIADTM. Installation, Operation & Maintenance Manual

OLYMPIADTM. Installation, Operation & Maintenance Manual OLYMPIADTM Installation, Operation & Maintenance Manual OLYMPIAD & LEGEND CHAIRS INSTALLATION OPERATION MAINTENANCE MANUAL HUSSEY SEATING COMPANY NO. BERWICK, MAINE 03906 TEL. 1-800-341-0401 FAX No. 1-207-676-0444

More information

THE AquaBlast & RocketRide FUNSLIDES

THE AquaBlast & RocketRide FUNSLIDES THE AquaBlast & RocketRide FUNSLIDES ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * S.R. SMITH AquaBlast TM & RocketRide TM FUNSLIDES TM ARE MANUFACTURED FOR INSTALLATION AND USE ON RESIDENTIAL

More information

THE CASCADE & SLINGER FUNSLIDES

THE CASCADE & SLINGER FUNSLIDES THE CASCADE & SLINGER FUNSLIDES ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * S.R. SMITH CASCADE TM & SLINGER TM FUNSLIDES TM ARE MANUFACTURED FOR INSTALLATION AND USE ON RESIDENTIAL INGROUND

More information

Installation Instructions for Solar Snow Pad (SSP-T-3)

Installation Instructions for Solar Snow Pad (SSP-T-3) Installation Instructions for Solar Snow Pad (SSP-T-3) Warning- Do not use this product on solar arrays where the calculated array snow loads exceed 50 pounds per square foot (psf). Most solar panels are

More information

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION SECTION R507 DECKS R507.1 Application. The provisions of this section shall provide prescriptive requirements for the design and construction of all uncovered, wood-framed, single-span exterior decks.

More information

Chapter 23. Garage Construction

Chapter 23. Garage Construction Chapter 23. Garage Construction 23.1 ESTABLISHING CHALK LINES 23.2 MEASURING AND CUTTING WALL PLATES 23.3 MARKING WINDOW & DOOR LOCATIONS ON EXTERIOR WALL PLATES 23.4 MARKING STUDS ON EXTERIOR WALL PLATES

More information

THE ROGUE TM FUNSLIDE TM

THE ROGUE TM FUNSLIDE TM THE ROGUE TM FUNSLIDE TM ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * S.R. SMITH ROGUE TM FUNSLIDES TM ARE MANUFACTURED FOR INSTALLATION AND USE ON RESIDENTIAL INGROUND POOLS ONLY. ROGUE

More information

PD 3 Dowel Cradle. Load Transfer System Industrial Slab on Ground

PD 3 Dowel Cradle. Load Transfer System Industrial Slab on Ground PD 3 Dowel Cradle Industrial Slab on Ground Provides the flattest joints Assists in reducing long term maintenance costs Extends the life-cycle of the floor and the asset Engineered to meet Super Flat

More information

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS Fence Installation Guide 3', 4' & 6' High INSTALLATION GUIDE These instructions are designed to assist both professional installers and do-it-yourselfers

More information

Storefront Installation Guide

Storefront Installation Guide Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation

More information

CONSTRUCTION / HOUSING

CONSTRUCTION / HOUSING CONSTRUCTION / HOUSING - PRINCE EDWARD ISLAND APPLIED MATHEMATICS 80A Table of Contents Construction/ Housing Reading a Tape Measure (Imperial)... - Using a Carpenter s Square... -5 Checking for Squareness

More information

TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS

TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P.O. Box 400 1017 SW Berg Parkway Canby, Oregon 97013 Phone: (503) 266-2231 Fax: (503) 266-4334

More information

Release Notes - Fixes in Tekla Structures 2016i SP1

Release Notes - Fixes in Tekla Structures 2016i SP1 Release Notes - Fixes in Tekla Structures 2016i SP1 is modified., the ID of the connection plate is not changed anymore when the connection now uses normal rebar groups instead of tapered groups., the

More information

Installation Instructions

Installation Instructions Installation Instructions For Models: Model Number / Description File Name 1540 Classic Series P-Lam Toilet Partitions 1540.pdf 1 INSTALLATION INSTRUCTIONS LAMINATED PLASTIC TOILET PARTITIONS 1540 Classic

More information

Architect. Architect.

Architect. Architect. The The line line sketch sketch with with modified modified height height for for plinth plinth floor floor is is displayed. displayed. Open Open Architectural Architectural plan plan file, file, which

More information

Release Notes - Fixes in Tekla Structures 2016i PR1

Release Notes - Fixes in Tekla Structures 2016i PR1 Release Notes - Fixes in Tekla Structures 2016i PR1, you can now set the to either or. is modified., the ID of the connection plate is not changed anymore when the connection now uses normal rebar groups

More information

Total precast solution for large stadium projects meet tight schedule

Total precast solution for large stadium projects meet tight schedule Tailor Made Concrete Structures Walraven & Stoelhorst (eds) 2008 Taylor & Francis Group, London, ISBN 978-0-415-47535-8 Total precast solution for large stadium projects meet tight schedule T.J. D Arcy

More information

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785) 141 E 1450 Rd. Lawrence, KS 66044 (75) 594-5696 Perma-Column Installation Instructions i Unlike any other concrete post-frame foundation system, Perma-Column Precast Concrete Piers use 10,000 psi concrete

More information

CENTER WING SECTION (CWS) WORK REPORT

CENTER WING SECTION (CWS) WORK REPORT CENTER WING SECTION (CWS) WORK REPORT No. Check Parts / Description Qty PHASE 1: Preparations 1 [ ] 6V1-3 Rear ribs 2R & 2L 1 [ ] L Angle 6 2 [ ] 6V2-1 Rear Ribs.032 2R & 2L 2 [ ] 6V5-1 Gear Rib Doubler

More information

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals BASIC REQUIREMENTS Irrespective of the type of pavers or tiles that will be installed over pedestals, the following basic requirement must be met. Decks must be designed not to exceed the load capacity

More information

THE ROGUE TM GRAND RAPIDS TM ASSEMBLY AND INSTALLATION INSTRUCTIONS

THE ROGUE TM GRAND RAPIDS TM ASSEMBLY AND INSTALLATION INSTRUCTIONS THE ROGUE TM GRAND RAPIDS TM ASSEMBLY AND INSTALLATION INSTRUCTIONS CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P.O. Box 400 1017 SW Berg Parkway Canby, Oregon 97013 (503) 266-2231 (503)

More information

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE Triner Scale & Mfg. Co., Inc. 8411 Hacks Cross Rd. Olive Branch, MS 38654 Phone: 800-238-0152 Fax: 662-809-2386 Description The Triner Scale Model

More information

GLOSSARY OF TERMS SECTION 8

GLOSSARY OF TERMS SECTION 8 GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the

More information

Post & Rail Crossbuck

Post & Rail Crossbuck Post & Rail Crossbuck 1. Getting Started 6. Crossbuck Be sure to call underground prior to digging Assemble gates (if necessary) and decide where they will be located Stake out the fence line Space and

More information

TURBOTWISTER TM ASSEMBLY AND INSTALLATION INSTRUCTIONS

TURBOTWISTER TM ASSEMBLY AND INSTALLATION INSTRUCTIONS TURBOTWISTER TM ASSEMBLY AND INSTALLATION INSTRUCTIONS CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P.O. Box 400 1017 SW Berg Parkway Canby, Oregon 97013 Phone: (503) 266-2231 Fax: (503)

More information

Independent Containment System (ICS)

Independent Containment System (ICS) Installing the Independent Containment System (ICS) Complete these instructions to install the Independent Containment System (ICS). Prerequisites This installation requires a team of at least two people.

More information

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA 94544-1395 PUBLIC WORKS DESIGN GUIDELINES TABLE OF CONTENTS SD-100 SERIES SPECIAL DRAWINGS SD-100 8/1991 SILT

More information

TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS

TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P.O. Box 400 1017 SW Berg Parkway Canby, Oregon 97013 Phone: (503) 266-2231 Fax: (503) 266-4334

More information

TECHNICAL MANUAL. OPTIMAJOINT Free Movement Joint. Free Movement Joint System for Heavy Traffic

TECHNICAL MANUAL. OPTIMAJOINT Free Movement Joint. Free Movement Joint System for Heavy Traffic TECHNICAL MANUAL OPTIMAJOINT Free Movement Joint Free Movement Joint System for Heavy Traffic Version: PEIKKO GROUP 12/2018 OPTIMAJOINT Free Movement Joint Free Movement Joint System for heavy traffic

More information

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01 MOUNT INSTALLATION GUIDE PUB5JAN0 SM SOLAR Wrenches and Torque Wrench Size Recommended Torque (ft-lbs) /4 Hardware 7/6 *0 3/8 Hardware 9/6 *30 # Hardware 5/6 0 Torques are not designed for use with wood

More information

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND Flanged Dowel Box INDUSTRIAL SLAB ON GROUND Designed for construction joints in Post Tension or large shrinkage specifications Large lateral movement and expansion capacity Eliminates the need to drill

More information

Project Booklet. Structural Drafting with AutoCAD

Project Booklet. Structural Drafting with AutoCAD Project Booklet Structural Drafting with AutoCAD Introduction 1 General Setup 2 Border and Title Block 3 Drafting the Foundation Plan (Plate 1) 8 Drafting the South Elevation (Plate 2) 11 Drafting Section

More information

PREFOAM - PERMANENT STADIUM SEATING RISER SYSTEM FOR FLOOR MONTED SEATING PART 1 GENERAL DESCRIPTION

PREFOAM - PERMANENT STADIUM SEATING RISER SYSTEM FOR FLOOR MONTED SEATING PART 1 GENERAL DESCRIPTION PREFOAM - PERMANENT STADIUM SEATING RISER SYSTEM FOR FLOOR MONTED SEATING PART 1 GENERAL DESCRIPTION 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

GlasRoc Sheathing Type X

GlasRoc Sheathing Type X Wall / Fire-Rated Systems 3-5/8" (92 mm) Steel Studs ProRoc Steel Stud System 3-5/8" (92 mm) Steel Track 3-1/2" (89 mm) Glass Fiber or Mineral Wool Insulation GlasRoc Sheathing Type X UL Design U465 Cavity

More information

DIVISION 12 - FURNISHINGS. Section General Discussion. Introduction

DIVISION 12 - FURNISHINGS. Section General Discussion. Introduction Section 12000 - General Discussion This General Discussion Section contains material which is important to the successful fabrication and/or installation of furnishings and equipment in construction projects.

More information

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15 MOUNT INSTALLATION GUIDE PUB5JUN5 Wrenches and Torque SM SOLAR Wrench Size Recommended Torque (ft-lbs) /4 Hardware 7/6 *0 3/8 Hardware 9/6 *30 # Hardware 5/6 0 Torques are not designed for use with wood

More information

Leveling Feet, Base Plates and Casters

Leveling Feet, Base Plates and Casters Leveling Feet, Base Plates and Casters 77 Leveling Foot 1 1 Fastening to profile end Fastening in T-slot of profile For leveling tables and light equipment. Ratchet-type height adjustment requires no tools.

More information

Extra Wide Heavy Duty Plastic Lockers Series Locker Installation Instructions

Extra Wide Heavy Duty Plastic Lockers Series Locker Installation Instructions Locker Installation Instructions Thank you for selecting Extra Wide Heavy Duty Plastic Lockers. We are confident that the quality and construction of the lockers will prove to be a good investment. These

More information

CURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START

CURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START ROOF ATTACHED VERANDAH ASSEMBLY INSTRUCTIONS Your supplementary guide to building an ATTACHED ROOF VERANDAH or PATIO This set of instructions should be used in conjunction with the Stratco instruction

More information

BIG RIDE ASSEMBLY AND INSTALLATION INSTRUCTIONS

BIG RIDE ASSEMBLY AND INSTALLATION INSTRUCTIONS BIG RIDE ASSEMBLY AND INSTALLATION INSTRUCTIONS S.R. SMITH BIG RIDE SLIDES ARE MANUFACTURED FOR INSTALLATION AND USE ON RESIDENTIAL INGROUND SWIMMING POOLS ONLY. THE BIG RIDE IS NEVER TO BE INSTALLED AND

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS Universal Top-of-Pole Mount 8 Modules (UTPM8) Module Type G ASSEMBLY INSTRUCTIONS step-by-step assembly and installation Version 1, Rev A PCN 022714-1 Universal Top-of-Pole Mount 8 Modules (UTPM8) for

More information

Number Object Category Attribute Name Explanation Examples Further comments

Number Object Category Attribute Name Explanation Examples Further comments 1 STORY 2 GRID 3 COLUMN 2 Story Elevation Absolute elevation for story (the name "story" is prefered over "level", as level is used in e.g. Revit Typically, our elevations for a project are all relative

More information

CYCLONE TM ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * *

CYCLONE TM ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * CYCLONE TM ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * S.R. SMITH CYCLONE TM SLIDES ARE MANUFACTURED FOR INSTALLATION AND USE ON INGROUND SWIMMING POOLS ONLY. THE CYCLONE TM IS NEVER TO

More information

Installation Instructions. Tools Needed. Tape measure. Level. Shovel or Post hole digger. Concrete. Drill. Stakes. Mallet or hammer.

Installation Instructions. Tools Needed. Tape measure. Level. Shovel or Post hole digger. Concrete. Drill. Stakes. Mallet or hammer. Installation Guide EcoStone Fence 1330 West 400 North Orem, UT 84057 Toll Free 1.866.648.9336 Tel. 1.801.655.5236 Fax 1.801.655.5240 www.ecostonefence.com Installation Instructions Introduction. These

More information

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts Capped Cellular PVC Fencing Installation Guide Table of Contents Storage and Handling Tools Needed Fence Layout and Locating Posts Installation instructions 4 x 4 Over Sleeve Post - 3.5 Rail Privacy Shadowbox

More information

Series Sloped glazed Curtain wall. Installation Instructions

Series Sloped glazed Curtain wall. Installation Instructions Series 5600 Sloped glazed Curtain wall Installation Instructions Part NO. Y308 February 2013 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines. 3-4 II. Gutter and Mullion Assembly.. 5 III. End

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS Universal Top-of-Pole Mount 6 Modules (UTPM6) Module Type G ASSEMBLY INSTRUCTIONS step-by-step assembly and installation Version 1, Rev A PCN 020314-1 Universal Top-of-Pole Mount 6 Modules (UTPM6) for

More information

Standard Signs Manual

Standard Signs Manual Standard Signs Manual NEW, CHANGED, OR DELETED 1/2017 STANDARD SIGN DETAILS Title Page Number Fractions... 101 Straight Arrows... 102 Double Head Arrows... 102A Double Head Arrows - 90... 102B Advance

More information

Multi-Stage ASSEMBLY INSTRUCTIONS ST-8100 SERIES. 125 TAYLOR PARKWAY ARCHBOLD, OH PHONE: (419) FAX: (419)

Multi-Stage ASSEMBLY INSTRUCTIONS ST-8100 SERIES. 125 TAYLOR PARKWAY ARCHBOLD, OH PHONE: (419) FAX: (419) 125 TAYLOR PARKWAY ARCHBOLD, OH 43502 PHONE: (419) 445-8915 FAX: (419) 445-0367 www.biljax.com Multi-Stage ST-8100 SERIES ASSEMBLY INSTRUCTIONS ALL DRAWINGS ARE FOR ILLUSTRATION ONLY. PRINTED IN U.S.A.

More information

GENERAL ISOMETRIC LAYOUT

GENERAL ISOMETRIC LAYOUT EXISTING OR PROPOSED WIPER WALL SUPPORT STRUCTURE GATE LID CARBATHAN HG 0 WEB GRAY LOWER PAN GRATING ALUMINUM WIPER WALL CARBATHANE HG, 90 GRAY STRUCTURAL SPECIFICATIONS:. FLOODGATE MATERIAL TO BE ALUMINUM

More information

1. Determine Home Design 2. Understand StoneSkirt TM Components 3. Perform StoneSkirt TM Installation

1. Determine Home Design 2. Understand StoneSkirt TM Components 3. Perform StoneSkirt TM Installation TM Steps for Installation: 1. Determine Home Design 2. Understand StoneSkirt TM Components 3. Perform StoneSkirt TM Installation Tools Needed Rubber mallet (2 lb. or heavier) Cordless drill with at least

More information

Curtain Wall Installation Guide

Curtain Wall Installation Guide Curtain Wall Installation Guide Curtain Wall Installation Guide 1 IMPORTANT NOTICES! Important Notices & Information Manufacturer s Notes: The building envelope must be correctly prepared with weather

More information

Made possible by a generous grant from. Guidelines for Display Rules & Regulations 2014 Update

Made possible by a generous grant from. Guidelines for Display Rules & Regulations 2014 Update Made possible by a generous grant from Guidelines for Display Rules & Regulations 2014 Update X PERIMETER BOOTH Contents (3.658M) Linear Booth and Corner Booth 4 (3.658M) Perimeter Booth 5 End-cap Booth

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS Universal Top-of-Pole Mount 5 Modules (UTPM5) Module Type G ASSEMBLY INSTRUCTIONS step-by-step assembly and installation Version, Rev A PCN 0904- Universal Top-of-Pole Mount 5 Modules (UTPM5) for Module

More information

Exhibit Design Regulations

Exhibit Design Regulations Exhibit Design Regulations The National Automobile Dealers Association has developed these Exhibit Design Regulations in accordance with the guidelines set forth by the International Association of Exhibition

More information

Exhibit Design Regulations

Exhibit Design Regulations Exhibit Design Regulations The National Automobile Dealers Association has developed these Exhibit Design Regulations in accordance with the guidelines set forth by the International Association of Exhibition

More information

installation care & maintenance instructions moistureshield.com limited lifetime warranty

installation care & maintenance instructions moistureshield.com limited lifetime warranty installation care & maintenance instructions 866.729.2378 moistureshield.com limited lifetime warranty It s comforting to know that you re about to build a deck that gives you every possible advantage.

More information

COMPOSITE RAILING INSTALLATION

COMPOSITE RAILING INSTALLATION COMPOSITE RAILING INSTALLATION Tools All you ll need is a hammer and screw gun, circular saw (carbidetipped blade with fewer than 20 teeth is recommended), level, tape measure, rasp and blue chalk line.

More information

Chapter 3. Wall Layout

Chapter 3. Wall Layout GFCAHFH March 15, 2018 Construction Manual Version 18.0 Chapter 3. Wall Layout 3.1 LAYING OUT EXTERIOR WALLS 3.2 CUTTING EXTERIOR WALL PLATES 3.3 MARKING WINDOW AND DOOR LOCATIONS ON EXTERIOR WALL PLATES

More information

Installation Instructions

Installation Instructions Installation Instructions 000964 Revision F Installation Instructions for PIRIT Read this manual fully prior to starting installation. Call American eating Customer ervice with any questions. What you

More information

12X20 Breeze Pergola Assembly Manual Outdoor Living Today

12X20 Breeze Pergola Assembly Manual Outdoor Living Today 12X20 Breeze Pergola Assembly Manual Outdoor Living Today Revision #10 July 21th, 2015 Note: Post Mounting Hardware is NOT included in this kit. Please confirm with your local building permit office to

More information

Versatrac R-System Stock Extrusions, Clips and Accessories

Versatrac R-System Stock Extrusions, Clips and Accessories Versatrac R-System Extrusions are available in 300 series (for 3 3/4" walls) and 400 series (for 4 7/8" walls). Standard finishes are Satin Metallic Bronze, Satin Black, Satin White Baked Enamel, and Clear

More information

Suggested Reinforcement Detailing Practices Based on comments from R&D and ES ESS Committees

Suggested Reinforcement Detailing Practices Based on comments from R&D and ES ESS Committees Suggested Reinforcement Detailing Practices Based on comments from R&D and ES ESS Committees General 1. When detailing substructures, it is preferable not to use series bars unless necessary. The first

More information

TYPHOON ASSEMBLY AND INSTALLATION INSTRUCTIONS

TYPHOON ASSEMBLY AND INSTALLATION INSTRUCTIONS TYPHOON ASSEMBLY AND INSTALLATION INSTRUCTIONS CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P.O. Box 400 1017 SW Berg Parkway Canby, Oregon 97013 Phone: (503) 266-2231 Fax: (503) 266-4334

More information

Copyrighted Material. Copyrighted Material. Copyrighted. Copyrighted. Material

Copyrighted Material. Copyrighted Material. Copyrighted. Copyrighted. Material Engineering Graphics ORTHOGRAPHIC PROJECTION People who work with drawings develop the ability to look at lines on paper or on a computer screen and "see" the shapes of the objects the lines represent.

More information

Forming and Shoring Product Selector

Forming and Shoring Product Selector Forming and Shoring Product Selector Including RedForm LVL and RedForm-I65, I90, and I90H s Lightweight for Fast Installation Resists Bowing, Twisting, and Shrinking Available in Long Lengths Uniform and

More information

IMPORTANT -- SPECIAL INSTALLATION INSTRUCTIONS

IMPORTANT -- SPECIAL INSTALLATION INSTRUCTIONS IMPORTANT -- SPECIAL INSTALLATION INSTRUCTIONS ** READ ALL INSTALLATION INSTRUCTIONS BEFORE STARTING!** If at any point, you have questions, call 1-800-851-0865...(The manufacturer will not be responsible

More information

BLEACHER ASSEMBLY INSTRUCTIONS

BLEACHER ASSEMBLY INSTRUCTIONS CROWDPLEASER BLEACHER ASSEMBLY INSTRUCTIONS NOTE: These instructions are generic to all 2 row through 10 row bleachers. The drawings in this instruction sheet generally show assembly for a 21 foot, six

More information

50.24 Type, Size and Location Plans for Culverts, Bridges and Culvert Bridges

50.24 Type, Size and Location Plans for Culverts, Bridges and Culvert Bridges 50.24 Culverts, Bridges and Culvert Bridges Type, Size and Location (T, S & L) Plans shall be required for all Bridges, Culvert Bridges and Culverts of eight-foot (8') clear span or greater as follows:

More information

Chapter 7 - Porch Framing

Chapter 7 - Porch Framing Chapter 7 - Porch Framing Contents Chapter 7 - Porch Framing... 7-1 Timing & Prerequisites... 7-2 Concrete Porches Caps (Contractor)... 7-3 Organize the Porch Framing Lumber... 7-3 Types of Porch Roofs...

More information

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available. SECTION 105113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

12 x 12 Flat Top Pergola

12 x 12 Flat Top Pergola x Flat Top Pergola A S S E M B LY G U I D E Model: Freemont OPTIONAL ACCESSORY Bolt Down Bracket Kit ( for Pergola) Ver /NOV 00 AI-BP0-0- Ta b l e o f Co n t e n t s PAGE x Flat Top Pergola Introduction

More information

Installation Guide (888)

Installation Guide (888) BamDeck Installation Guide (888) 788-2254 The Collection Decking Systems BAMDECK 4G 5-7/16 Wide Plank Dims: 192 L x 5-7/16 W x 13/16 H BAMDECK 4G WIDE 8-1/4 Wide Plank Dims: 96 L x 8-1/4 W x 13/16 H BAMDECK

More information

Ultra Space Saver American Bicycle Security Company

Ultra Space Saver American Bicycle Security Company The Ultra Space Saver is userfriendly and allows easy access to bikes. It provides convenient space for u-lock security on nearly any bike, including bikes with fenders and fork shocks. The double-sided

More information

PLAYLAND 72 SPIRAL SLIDE 3.5 Posts, 3.5 Posts / 48 Grid and 5 Posts

PLAYLAND 72 SPIRAL SLIDE 3.5 Posts, 3.5 Posts / 48 Grid and 5 Posts PLAYLAND 72 SPIRAL SLIDE 3.5 Posts, 3.5 Posts / 48 Grid and 5 Posts USER GROUP: 2-12 RECOMMENDED CREW: 2 people TOOLS REQUIRED: T-30 TORX tool (supplied by manufacturer) T-45 TORX tool (supplied by manufacturer)

More information

Design Considera ons & Installa on Guidance

Design Considera ons & Installa on Guidance Design Considera ons & Installa on Guidance LiteSpace Interior Aluminum Framing provides a slim profile for glass walls and office fronts. It is designed to be cut to length on project sites for finished,

More information

Chapter 3. Wall Layout

Chapter 3. Wall Layout Chapter 3. Wall Layout 3.1 LAYING OUT EXTERIOR WALLS 3.2 CUTTING EXTERIOR WALL PLATES 3.3 MARKING WINDOW AND DOOR LOCATIONS ON EXTERIOR WALL PLATES 3.4 MARKING STUDS ON EXTERIOR WALL PLATES 3.5 LAYING

More information

Residential & Industrial Fence

Residential & Industrial Fence Residential & Industrial Fence Assembly Instructions CONTENTS 02: OVERVIEW & CONTENTS 03: PRODUCT SPECIFICATIONS 04: GETTING STARTED 05: WALL ATTACHMENT & LINE POST ASSEMBLY 06: CORNER POST ASSEMBLY 07:

More information

SECTION BULLET- RESISTANT DOORS

SECTION BULLET- RESISTANT DOORS 1 SECTION 08 3950 BULLET- RESISTANT DOORS PART 1- GENERAL 1.01 SUMMARY A. This Section Includes: 1. Bullet- resistant steel door and frame systems. 2. Door hardware for bullet- resistant steel door and

More information

Installation Instructions - Model V4JSD 1

Installation Instructions - Model V4JSD 1 Installation Instructions - Model V4JSD 1 Support Assemblies: Parts list: (Note see enclosed cut sheet for quantities and dimensional information) A vertical structural member (1 ½ x 1 ½ modular frame)

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS PRINTED IN USA Assembly Instructions Include: P/N: LL-04-5 Step : Site Preparation Step 0: Guard Rail Installation Step : Leg Assembly Step : Stairs Step 3-8: Setting the Stage Step

More information

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16 Equilibrium Conference Table Installation Instruction Revision B 11/07/16 Equilibrium End User Agreement Enwork Equilibrium table bases must be installed directly onto a four inch minimum thickness concrete

More information

Roof Tutorial Wall Specification

Roof Tutorial Wall Specification Roof Tutorial The majority of Roof Tutorial describes some common roof styles that can be created using settings in the Wall Specification dialog and can be completed independent of the other tutorials.

More information

Big expertise. Real convenience. Concrete commitment. stem

Big expertise. Real convenience. Concrete commitment. stem 1300 659 830 www.formdirect.com.au Big expertise. Real convenience. Concrete commitment. Stee l Pre-e P n g i n eere ly Fo conc d rete form, factory rmin ing s ystem built, re-u g sy sable stem Steel-Ply

More information

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS 1. DESCRIPTION THESE SPECIFICATIONS ARE FOR A PRECAST THREE SIDED ARCH STRUCTURE, HEADWALLS

More information

ASSEMBLY AND INSTALLATION INSTRUCTIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS ASSEMBLY AND INSTALLATION INSTRUCTIONS CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P.O. Box 400 1017 SW Berg Parkway Canby, Oregon 97013 (503) 266 2231 (503) 266 4334 www.srsmith.com 06

More information

FENCE INSTALLATION GUIDE 6 HIGH FENCE

FENCE INSTALLATION GUIDE 6 HIGH FENCE FENCE INSTALLATION GUIDE 6 HIGH FENCE 1.866.648.9336 www.simtekfence.com INSTALLATION GUIDE These instructions are designed to assist both professional installers and do-it-yourselfers of SimTek decorative

More information

OVERVIEW You are installing 2 Major components: SITE PREP Remove organics

OVERVIEW You are installing 2 Major components: SITE PREP Remove organics OVERVIEW You are installing 2 Major components: Dimensionally stable exterior frame with pre-drilled thread-bar holes. High yield thread-bar in a predetermined grid pattern (slab) and a heavy concentration

More information

APPLICATION FOR A BUILDING PERMIT

APPLICATION FOR A BUILDING PERMIT APPLICATION FOR A BUILDING PERMIT City of San Jacinto 595 S. San Jacinto Ave San Jacinto CA 92583 95.487.7330 fax 95.654.9896 Must print legibly, submit (3) sets of building and plot plans. Fill out all

More information

8.1 Control. 8.2 Sheet Setup

8.1 Control. 8.2 Sheet Setup 8.1 Control Responsibility for development of the pipe data sheets is in the hands of the project s drainage or roadway designer. Pipe data sheets should be developed after the drainage design is fairly

More information

Diamond Dowel. Load Transfer System INDUSTRIAL SLAB ON GROUND

Diamond Dowel. Load Transfer System INDUSTRIAL SLAB ON GROUND Diamond Dowel INDUSTRIAL SLAB ON GROUND Diamond Dowel designed for construction joints Tapered plate design allows for diagonal shrinkage Eliminates the need to drill or process formwork Design ensures

More information

2.9 WINDOW & DOOR BUCKS

2.9 WINDOW & DOOR BUCKS 2.9 WINDOW & DOOR BUCKS Bucks provide attachment surfaces for windows and doors while holding back concrete from these openings during concrete placement. Mark the center and edges of openings as you place

More information

24" B B Joint X501 Joint See MARKINGS Note PCB-RXX-350-TL3 " X501 Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOT

24 B B Joint X501 Joint See MARKINGS Note PCB-RXX-350-TL3  X501 Y301 (Typ.)  A PLAN (reinforced casting option shown) A  dia. Hinge Bar (Typ.) NOT B B Joint Joint See MARKINGS Note PCB-RXX-350-TL3 " Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOTES GENERAL: This barrier may be manufactured with reinforcing steel

More information

PANEL CRIB PIERS AND TOWERS

PANEL CRIB PIERS AND TOWERS CHAPTER 17 PANEL CRIB PIERS AND TOWERS Panel crib piers are made of trusses with panels set horizontally or vertically and are normally braced with transoms, sway bracing, rakers, bracing frames, and tie

More information

Constructing Wire Fences

Constructing Wire Fences 1 of 6 12/3/2010 9:48 AM University of Missouri Extension G1192, Reviewed October 1993 Constructing Wire Fences Richard E. Phillips Department of Agricultural Engineering This guide will provide some basic

More information

BOOTH CONSTRUCTION & DISPLAY REQUIREMENTS Huntington Convention Center Cleveland, Ohio February 7 9, 2018

BOOTH CONSTRUCTION & DISPLAY REQUIREMENTS Huntington Convention Center Cleveland, Ohio February 7 9, 2018 Linear, Corner and Perimeter Booths Linear booths, also called in line booths, are generally arranged in a straight line and have neighboring exhibitors on their immediate right and left, leaving only

More information

12 x 12 Flat Top Pergola

12 x 12 Flat Top Pergola x Flat Top Pergola Model: Freemont A S S E M B L Y G U I D E O P T I O N A L A C C E S S O R Y Bolt Down Bracket Kit ( for Pergola) Ver.-057 Ta b l e o f Co n t e n t s PAGE x Flat Top Pergola Introduction

More information