1 CHAPTER-E-21 Sl No Drawing Name Drawing Number 1 Single Line Diagram (GIS S/s) ODSSP/SS/SLD/1-REV-C 2 Single Line Diagram (Outdoor S/s) ODSSP/SS/SLD/3 3 Sub- station Layout for GIS Type ODSSP/SS/SLY/1 4 Sub- station Layout for Outdoor Type ODSSP/SS/SLY/2 5 T1 Column With Beam Arrangement in Substation ODSSP/SS/3/ REV-A 6 T2 Column With Beam Arrangement in Substation ODSSP/SS/4/ REV-A 7 G3 For 33 kv Incomer in Substation ODSSP/SS/ kv V Cross Arm for RS Joist in Substation ODSSP/SS/ kv SI Structure (Outdoor) in Substation ODSSP/SS/ kv CT Structure (Outdoor) in Substation ODSSP/SS/8 11 Earthmat Flat Jointing ODSSP/SS/9 12 Cable Trench for 1500 mm ODSSP/SS/10-REV-B 13 4 Bolted Tension Clamp ODSSP/SS/11-REV-B kv 1250A Double Tandem Double Break Centre Rotating Isolator With one Earth Switch 11 kv 1250A Double Tandem Double Break Centre Rotating Isolator With one Earth Switch 33 kv 1250A Double Tandem Double Break Centre Rotating Isolator Without Earth Switch 11 kv 1250A Double Tandem Double Break Centre Rotating Isolator Without Earth Switch Structural Detail of 33kV Tower Type- T8 & T9 in Substation ODSSP/SS/12 ODSSP/SS/13 ODSSP/SS/14 ODSSP/SS/15 ODSSP/SS/16 19 Structural Detail of Girder Type G-4 ODSSP/SS/17 20 Structural Detail of Girder Type G-6 ODSSP/SS/18

2 Structural Detail of 33kV Single Isolator without Earth Switch (OPTCL Sub-Station) Structural Detail of 33kV Double Isolator with & without Earth Switch (OPTCL Sub-Station) Structural Detail of 33kV CT & PI (OPTCL Sub- Station) ODSSP/SS/19 ODSSP/SS/20 ODSSP/SS/21 24 H type Pole Design ODSSP/SS/22 25 Foundation of H type Pole ODSSP/SS/23/REV-A 26 Cross Sectional View of 33kV Cable, Un- Armoured, Single Core & 11kV Cable, Armoured, Three Core ODSSP/SS/24-REV-C 27 Cable Trench for 750 mm ODSSP/SS/25 28 Cable Trench for 500 mm ODSSP/SS/ ½ C LT Power Cable ODSSP/SS/27-REVA T1A & T2A Column With Beam Arrangement in Substation T3 Column With Beam Arrangement in Substation Bolt Arrangement for 33kV Outdoor Substation. ODSSP/SS/28 ODSSP/SS/29 ODSSP/SS/30 33 G1, G2 & R1 For 33 kv Incomer in Substation ODSSP/SS/31 34 DP structure used for 11kV Gantry at S/s ODSSP/SS/32 35 DP structure for 33/0.4kV Station Transformer ODSSP/SS/33 36 DP structure in S/s and Line ODSSP/LINE/1- REV-B kg 10 Mtr PSC Pole ODSSP/ LINE / kV V Cross arm for RS Joist Pole ODSSP/LINE / kV V Cross arm for PSC Pole ODSSP/ LINE /5-REV-A 40 Earthing Device ODSSP/LINE/6 41 Arrangements of Spikes with Column Structure ODSSP/LINE/7 42 Tension Assembly for Earth wire ODSSP/LINE/8 43 Suspension Assembly for Earth wire ODSSP/LINE/9

3 44 +6M Extension to PC Tower Structure (River Crossing) ODSSP/LINE/10 45 Jointing of GI R.S Joist Pole ODSSP/LINE/ & 11 KV Danger Board ODSSP/LINE/15 47 PC Tower Structure Top ODSSP/LINE/16 48 PC Tower Structure Template ODSSP/LINE/17 49 PC Tower Structure Bottom ODSSP/LINE/18 50 Foundation of PC Tower Structure ODSSP/LINE/19 51 Single Tension Hardware Assembly ODSSP/LINE/20 52 Double Tension Hardware Assembly ODSSP/LINE/21 53 Cross Sectional View of 33kV Cable, Un- Armoured, Single Core & 11kV Cable, Armoured, Three Core ODSSP/LINE/25-REV-C 54 33kV Single Circuit Laying Arrangement ODSSP/LINE/26-REV-A 55 11kV Single Circuit Laying Arrangement ODSSP/LINE/27-REV-A 56 Foundation for PSC Pole ODSSP/ CIVIL /1-REV-A 57 Foundation for RS Joist Pole ODSSP/ CIVIL /2-REV-B 58 Foundation For T1 & T2 Columns (Sub- Station) ODSSP/CIVIL/3- REV-A 59 Foundation for Power Transformer ODSSP/CIVIL/4- REV-C 60 Foundation for 100 KVA Station Transformer ODSSP/CIVIL/5- REV-B 61 Retaining Wall for Switchyard ODSSP/CIVIL/6- REV-A 62 Drain ODSSP/CIVIL/7- REV-A 63 Foundation Plan for T1,T2,T1A, T2A, T3 Column with Foundation Bolt ODSSP/CIVIL/8 64 Foundation for 33kV VCB with CT (Outdoor) ODSSP/CIVIL/9 65 Road Inside Sub-Station ODSSP/ CIVIL /11-REV-B 66 Layout Plan of Compound Wall ODSSP/ CIVIL / Structural Design & Detailing of Compound Wall (Pile Foundation) Structural Design & Detailing of Compound Wall (Open Foundation) ODSSP/ CIVIL /13, Sheet-1/2 ODSSP/ CIVIL /13-REV-A, Sheet-2/2

4 69 Culvert Drawing ODSSP/ CIVIL /14 Left Side & Front Side Elevation Drawing of ODSSP/ CIVIL /15-REV-A, 70 Control Room Building for Flood Zone Sheet-1/5 71 Rear Side & Right Side Elevation Drawing of Control Room Building for Flood Zone ODSSP/ CIVIL /15, Sheet-2/ Architectural Drawing for First Floor & Terrace Plan of Control Room Building for Flood Zone Architectural Drawing for Ground Floor and Sectional Plan of Control Room Building for Flood Zone Architectural Drawing for Lower Floor Plan of Control Room Building for Flood Zone First Floor Roof Beam Reinforcement Details of Control Room Building for Flood Zone Ground Floor Roof Beam Reinforcement Details of Control Room Building for Flood Zone Lower Floor Roof Beam and Lintel Reinforcement Details of Control Room Building for Flood Zone Staircase and other Misc. details of Control Room Building for Flood Zone Column & Foundation Reinforcement Details of Control Room Building for Flood Zone (Pile Foundation) Pile, Pile Cap & Grade Beam Reinforcement Details of Control Room Building for Flood Zone (Pile Foundation) 81 Column & Foundation Reinforcement Details of Control Room Building for Flood Zone (Open Foundation) ODSSP/ CIVIL /15, Sheet-3/5 ODSSP/ CIVIL /15, Sheet-4/5 ODSSP/ CIVIL /15, Sheet-5/5 ODSSP/ CIVIL /16, Sheet-1/4 ODSSP/ CIVIL /16, Sheet-2/4 ODSSP/ CIVIL /16, Sheet-3/4 ODSSP/ CIVIL /16, Sheet-4/4 ODSSP/ CIVIL /17, Sheet-1/2 ODSSP/ CIVIL /17, Sheet-2/2 ODSSP/ CIVIL /18, Sheet-1/2

5 82 Plinth Beam & Lintel Reinforcement Details of Control Room Building for Flood Zone (Open Foundation) 83 All Side Elevation & Sectional Drawing of Control Room Building for Non-Flood Zone 84 Ground Floor & Terrace Plan for Non-Flood Zone 85 Roof Beam Reinforcement Details of Control Room Building for Non-Flood Zone 86 Plinth Beam & Lintel Reinforcement Details of Control Room Building for Non-Flood Zone 87 Staircase and other Misc. details of Control Room Building for Non-Flood Zone 88 Column & Foundation Reinforcement Details of Control Room Building(Open Foundation) for Non-Flood Zone 89 Column & Foundation Reinforcement Details of Control Room Building(Pile Foundation) for Non-Flood Zone 90 Pile, Pile Cap & Grade Beam Reinforcement Details of Control Room Building(Pile Foundation) for Non-Flood Zone ODSSP/ CIVIL /18, Sheet-2/2 ODSSP/ CIVIL /19, Sheet-1/5 ODSSP/ CIVIL /19, Sheet-2/5 ODSSP/ CIVIL /19, Sheet-3/5 ODSSP/ CIVIL /19, Sheet-4/5 ODSSP/ CIVIL /19, Sheet-5/5 ODSSP/ CIVIL /20-REV-A ODSSP/ CIVIL /21, Sheet-1/2 ODSSP/ CIVIL /21, Sheet-2/2

6 PROPOSED SINGLE LINE DIAGRAM FOR 2X5/8 MVA, 33/11 kv GIS INDOOR S/S (33 kv GIS INDOOR, 11 kv AIS INDOOR) 33 kv INCOMER-II (WHERE REQUIRED) 33 kv INCOMMER-I DP (H pole) 33kV INDOOR GIS O/C & E/F METER SPARE 33 kv OUTDOOR ISOTOR 1250A/25kA for 3 Sec 33kV INDOOR CT /1-1-1 A 35 sq. mm UG CABLE 100 mtr. IVT 33kV VCB 630A/25kA for 3 Sec 33kV PROTECTION METERING 33/ 3 kv/ 110/ 3/ 110/ 3V DISCONNECTOR 630 A 33kV DISCONNECTOR 630 A 33kV VCB 630A/25kA for 3 Sec 33kV BUS S 33kV AB SWITCH ON DP 200A/25kA for 3 Sec FUSE DIFFRENTIAL PROTECTION 33kV INDOOR CT /1-1-1A METER O/C & E/F 100kVA,33 kv/0.433 kv STN. TRF DP 5/ 8 MVA POWER TRF NCT 5/ 8 MVA POWER TRF NCT 11kV INDOOR AIS DP 11kV BUS COUPLER VCB 11kV CT /1-1-1A 11kV VCB DP DIFFRENTIAL PROTECTION METER O/C & E/F 11kV BUS IVT PROTECTION METERING 33/ 3 kv/ 110/ 3/ 110/ 3V 11kV VCB 630A/25kA for 3 Sec 11kV INDOOR CT / A 11kV ISOTOR 1250A/25kA for 3 Sec DP 11kV FEEDER I 11kV FEEDER II 11kV FEEDER III 11kV FEEDER IV DRAWING NO - ODSSP/ SS/ SLD/1-REV-C

7 PROPOSED SINGLE LINE DIAGRAM FOR 2X3.15/ 5/ 8 MVA, 33 kv OUTDOOR & 11kV INDOOR S/S 33 kv INCOMER-I 33 kv INCOMMER-II 33kV OUTDOOR CT Second Feeder installed in requirement of two incoming feeder 33KV VCB IVT 33KV VCB CT 33/ 11KV TRF 11kV INDOOR AIS DP 11kV BUS COUPLER VCB 11kV CT /1-1-1A 11kV VCB DIFFRENTIAL PROTECTION METER O/C & E/F IVT PROTECTION METERING 11/ 3 kv/ 110/ 3V- 110/ 3V 11kV BUS 11kV VCB 630A/25 ka for 3 Sec O/C & E/F METER SPARE DP 11kV CT / A 11kV ISOTOR 1250A/25kA for 3 Sec 11kV FEEDER I 11kV FEEDER II 11kV FEEDER III 11kV FEEDER IV DRAWING NO - ODSSP/ SS/ SLD/ 3

8 CABLE TRENCH BAFFLE WALL SUB-STATION YOUT(GIS) INCOMING-2 INCOMING-1 T-1 T-2 T-1 ISO DP USING 150X150 G.I RS JOIST CABLE TRENCH 100KVA, 33/0.4kV STATION TRF 33/11 kv TRF-2 1.6MX1.6MX2M OIL SUMP PIT 33/11 kv TRF-1 SERVICE PORTICO 3MX4M SECU RITY 2MX2M CABLE TRENCH GATE ROAD DOOR BATTERY ROOM 2X2M A B C D OFFICE ROOM 2X3M CABLE TRENCH TOWARDS 33 kv PANEL INCOMR-I TRF-I TRF-II INCOMR-II IVT IVT FDR-I FDR-II TRF-I 33kV PANEL 11kV PANEL B/C CONTROL ROOM CUM SWITCHGEAR BUILDING G.I.S TRF-II FDR-III FDR-IV IVT DOOR STORE ROOM 2X3M CUSTOMER CARE OFFICE 4X3M OFFICE TOILET TOILET 2X1.5 M 2X1.5 M 2350 mm SERVICE VARENDAH CUM STAIRCASE GATE TOWARDS 11kV PANEL CABLE TRENCH ISO ISO ISO ISO FEEDER-1 FEEDER-2 FEEDER-3 FEEDER-4 NOTE:- A-CHARGER,B-ACDB, C-RTCC-1 & RTCC-2, D-RTU DRG NO.- ODSSP / SS / SLY/ 1

9 BAFFLE WALL SUB-STATION YOUT(OUTDOOR) INCOMING-2 INCOMING-1 T-1 ISO PI T-2 T-1 CT CT CB CB T-1A T-2A T-1A AB SWITCH HG FUSE IVT 100KVA, 33/0.4kV STATION TRF T-1A T-2A T-1A CB CB CT CT T1 PI T2 PI T2 R1 33/11 kv TRF-2 33/11 kv TRF-1 SERVICE PORTICO 3MX4M T3 T3 SECU RITY 2MX2M GATE ROAD DOOR BATTERY ROOM 2X2M A B C D OFFICE ROOM 2X3M 33kV PANEL INCOMR-I TRF-I TRF-II INCOMR-II IVT FDR-I FDR-II TRF-I CONTROL ROOM CUM SWITCHGEAR BUILDING A.I.S B/C TRF-II FDR-III FDR-IV IVT DOOR STORE ROOM 2X3M CUSTOMER CARE OFFICE 4X3M OFFICE TOILET 2X1.5 M TOILET 2X1.5 M 2350 mm SERVICE VARENDAH CUM STAIRCASE GATE 11kV PANEL ISO ISO ISO ISO FEEDER-1 FEEDER-2 FEEDER-3 FEEDER-4 NOTE:- A-CHARGER,B-ACDB, C-RTCC-1 & RTCC-2, D-RTU DRG NO.- ODSSP / SS / SLY/ 2

10 DRG NO-ODSSP/SS/3/REV-A T1 COLUMN WITH BEAM ARRANGEMENT

11 x75x6 mm channel DRG NO-ODSSP/SS/4/REV-A T2 COLUMN WITH BEAM ARRANGEMENT

12

13

14

15

16

17

18

19 DRG. NO- ODSSP/SS/12

20

21

22 DRG. NO- ODSSP/SS/15

23

24

25

26

27

28

29

30

31 CROSS-SECTIONAL VIEW OF 33kV & 11kV CABLE FOR S/S AL.CONDUCTOR SEMICONDUCTING WATER SWELBLE TAPE CONDUCTOR SCREENING (EXTRUTED SEMICONDUCTING XLPE) INSUTION MATERIAL (TREE RETARDANT) INSUTION SCREENING (SEMICONDUCTING XLPE ) WATER SEALING TAPE METALIC SHEATH (CORRUGATED AL.) BITUMINOUS TAPE OUTER SHEATH(FR PVC TYPE ST-2) CONDUCTING YER (GRAPHITE COATING) CROSS-SECTIONAL VIEW OF 33 kv 1C, UN-ARMOURED CABLE AL.CONDUCTOR SEMICONDUCTING WATER SWELBLE TAPE CONDUCTOR SCREENING (EXTRUTED SEMICONDUCTING XLPE) INSUTION MATERIAL (XLPE TREE RETARDANT) INSUTION SCREENING (SEMICONDUCTING XLPE+COPPER TAPE ) WATER SWELBLE TAPE PVC FILLER INNER SHEATH (PVC ST-2 EXTRUDED) ARMOURING GALVANISED STEEL/WIRE OUTER SHEATH(FR PVC TYPE ST-2) CROSS-SECTIONAL VIEW OF 11kV 3C, ARMOURED CABLE Drg No.-ODSSP/SS/24/REV-C

LIST OF DRAWINGS. 1. C/ENGG/NEPAL/DANA/SLD/01 (2 SHEET) Single Line diagram of 220/132/33kV Dana Substation

LIST OF DRAWINGS. 1. C/ENGG/NEPAL/DANA/SLD/01 (2 SHEET) Single Line diagram of 220/132/33kV Dana Substation Annexure-I LIST OF DRAWINGS S. No. DRAWING NO. TITLE Project specific drawings A) 220/132/33kV Dana Substation 1. C/ENGG/NEPAL/DANA/SLD/01 (2 SHEET) Single Line diagram of 220/132/33kV Dana Substation

More information

SLD FOR 132/33 KV DUB STATION, SOMANATHPUR

SLD FOR 132/33 KV DUB STATION, SOMANATHPUR SLD FOR 132/33 KV DUB STATION, SOMANATHPUR 132 KV BAYS TRANSF 02 NOS. 132kV MAIN BUS 132kV RESERVE BUS 20/40 MVA, 132/33kV TRANSFORMER1 20/40 MVA, 132/33kV TRANSFORMER 2 STN TFR 33/0.4KV 250KVA 33KV BAY

More information

SCHEDULE OF WORK. Balmer Lawrie Co. Ltd. PRICED BID (PART-II) MMLH

SCHEDULE OF WORK. Balmer Lawrie Co. Ltd. PRICED BID (PART-II) MMLH SCHEDULE OF WORK Supply, Installation, Testing & Commissioning (SITC) of 33KV Electrical Substation for Multi Modal Logistics Hub at Visakhapatnam, Andhra Pradesh. Tender No. MMLH /HTELEC/PT /18 dated

More information

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01 SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING Rev. 01 This specification is property of SEC and subject to change or modification without any notice

More information

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated

More information

List of Item Codes of Various Materials Purchased by Materials Management Cell(H.O.,Mumbai) through e-tender website https://cpa1.mahadiscom.

List of Item Codes of Various Materials Purchased by Materials Management Cell(H.O.,Mumbai) through e-tender website https://cpa1.mahadiscom. List of Item Codes of Various Materials Purchased by Materials Management Cell(H.O.,Mumbai) through e-tender website https://cpa1.mahadiscom.in : M.M. PURCHASE GROUP-I : New Service Connection (N.S.C.)

More information

Substation Preventive Maintenance

Substation Preventive Maintenance Substation Preventive Maintenance PROVINCIAL ELECTRICITY AUTHORITY 1 Presentation Contents 1) A kind of substation 2) Electrical equipment details of AIS substation 3) Electrical equipment details of GIS

More information

Single Line Diagram of Substations

Single Line Diagram of Substations Single Line Diagram of Substations Substations Electric power is produced at the power generating stations, which are generally located far away from the load centers. High voltage transmission lines are

More information

Fatima Michael college of Engineering and Technology

Fatima Michael college of Engineering and Technology Fatima Michael college of Engineering and Technology DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2303 TRANSMISSION AND DISTRIBUTION SEM: V Question bank UNIT I INTRODUCTION 1. What is the electric

More information

KENYA ELECTRICITY GENERATING COMPANY LTD

KENYA ELECTRICITY GENERATING COMPANY LTD KENYA ELECTRICITY GENERATING COMPANY LTD TENDER No. KGN-HYD-014-2016 TENDER FOR REHABILITATION OF PROTECTION EQUIPMENT FOR MASINGA HYDRO POWER STATION 20/06/2016 ADDENDUM NO. 1 In accordance with the tender

More information

Unit 2. Single Line Diagram of Substations

Unit 2. Single Line Diagram of Substations Unit 2 Single Line Diagram of Substations Substations Electric power is produced at the power generating stations, which are generally located far away from the load centers. High voltage transmission

More information

PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA

PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA Generally inspection of electrical installations is carried out under Regulation-30 (Periodical inspection & testing) & Regulation-43 (Approval

More information

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured) WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,

More information

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS TESTS ON TRANSFORMERS 1. IR Values This is measured to measure the Insulation Resistance of the whole transformer. a) For 33/11 KV Power Transformer

More information

GENERAL TECHNICAL SPECIFICATION

GENERAL TECHNICAL SPECIFICATION GENERAL TECHNICAL SPECIFICATION September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091.

More information

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240

More information

Form-IV. Form of Inspection/Test Report. (Under Regulation 43)

Form-IV. Form of Inspection/Test Report. (Under Regulation 43) Form-IV Form of Inspection/Test Report (Under Regulation 43) 1. Name and address of the Chartered Electrical Safety Engineer 2. Name and address of the consumer (or) Owner(or) supplier: Contact No: E-Mail:

More information

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS) TENDER DOCUMENT NIT No. DLI/C&E/WI-665/535R FOR Tender for Supply of 3CX185 mm2, 11 KV (UE) grade, Power Cable for Augmentation of Raw Material Handling Receipt and Handling Facilities with new OHP Part

More information

Underground System Design TADP 547

Underground System Design TADP 547 Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas Industry Organizations Several professional organizations develop standards

More information

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01 SEC DISTRIBUTION GROUNDING STANDARD SDCS-03 Part-II Rev.01 SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING Rev. 01 This specification is property of SEC

More information

Manual: Distribution Substation Manual (DSM) Section D: Substation Drawing Revision List

Manual: Distribution Substation Manual (DSM) Section D: Substation Drawing Revision List Manual: Distribution Substation Manual (DSM) Section D: Substation Drawing Revision List Standard Number: HPC-5DA-07-0011-2012 Document Control Author Name: Viswa Easwaran Position: Standards Engineer

More information

POTENTIAL TRANSFORMER

POTENTIAL TRANSFORMER POTENTIAL TRANSFORMER September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN:

More information

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables NO: 452-1 Office

More information

SAUDI COMMITTEE FOR PALESTINIAN RELEIF

SAUDI COMMITTEE FOR PALESTINIAN RELEIF SAUDI COMMITTEE FOR PALESTINIAN RELEIF ITB 2014-042 PAL 10-49740 /Construction of 300 Residential Units in Rafah Package #12: Electrical and Telecommunication Works Part C. SECTION 9: PRICE SCHEDULE (Bill

More information

GENERAL TECHNICAL SPECIFICATION (Turnkey Work)

GENERAL TECHNICAL SPECIFICATION (Turnkey Work) GENERAL TECHNICAL SPECIFICATION (Turnkey Work) March 2015 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar,

More information

MV network design & devices selection EXERCISE BOOK

MV network design & devices selection EXERCISE BOOK MV network design & devices selection EXERCISE BOOK EXERCISES 01 - MV substation architectures 02 - MV substation architectures 03 - Industrial C13-200 MV substation 04 - Max. distance between surge arrester

More information

NISSAN NV200 CHEVY CITY EXPRESS WALL LINER KIT INSTALLATION INSTRUCTIONS

NISSAN NV200 CHEVY CITY EXPRESS WALL LINER KIT INSTALLATION INSTRUCTIONS NISSAN NV200 CHEVY CITY EXPRESS WALL LINER KIT INSTALLATION INSTRUCTIONS NOTES: 1. Before commencing, remove all wall liners and D Rings already installed in the vehicle. 2. Consult layout PDF and compare

More information

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM Technical Specification of Back Clamp for LT Cross Arm (MS) Back clamp for LT Cross Arm made out of 50 x 6mm MS Flat suitable for 8m X 300 Kg PSC poles. After fabrication the cross arm shall be painted

More information

CUSTOMER MANUAL. General Installation Guide. Indoor/Outdoor RF Repeater Systems MARCH 1,

CUSTOMER MANUAL. General Installation Guide. Indoor/Outdoor RF Repeater Systems MARCH 1, CUSTOMER MANUAL General Installation Guide Indoor/Outdoor RF Repeater Systems MARCH 1, 2018 WWW.EXCELWAVETECHNOLOGIES.COM 1-888-329-2878(Tel) 1-888-318-5528(Fax) Disclaimer This document is provided for

More information

Ritz Instrument Transformers GmbH. Welcome

Ritz Instrument Transformers GmbH. Welcome Ritz Instrument Transformers GmbH Welcome About Ritz together with over 200 years of experience in instrument transformer production since 1945 since 1945 since 1945 since 1904 RITZ Group - Organization

More information

MERALCO Standards: Electrical Design. Engr. Eduard Mercado Electrical Design Team

MERALCO Standards: Electrical Design. Engr. Eduard Mercado Electrical Design Team MERALCO Standards: Electrical Design Engr. Eduard Mercado Electrical Design Team Electrical Design Standards SERVICE VOLTAGES SECONDARY METERED - 240 V, 400 V, 460 V PRIMARY METERING -34.5 kv, 13.8 kv

More information

NSP/007/028 Guidance On Substation Design: Drawing Submission Requirement

NSP/007/028 Guidance On Substation Design: Drawing Submission Requirement Version:- 1.0 Date of Issue:- January 2016 Page 1 of 25 NSP/007/028 Guidance On Substation Design: Drawing Submission Requirement 1. Purpose The purpose of this document is to provide guidance on the submission

More information

NSP/007/019 - Guidance on Substation Design: EHV Substation Drawing Policy

NSP/007/019 - Guidance on Substation Design: EHV Substation Drawing Policy Version:- 1.1 Date of Issue:- Feb 2015 Page 1 of 13 NSP/007/019 - Guidance on Substation Design: EHV Substation Drawing Policy 1. Purpose The purpose of this document is to outline the Northern Powergrid

More information

Welcome to the Session on. HT Distribution Network

Welcome to the Session on. HT Distribution Network Welcome to the Session on HT Distribution Network Learning Objective By the end of this session you will be able to: Explain the HT distribution network breakdown maintenance - possible faults, identification

More information

Agenda. Earthing of Telecom Installations using Single Point Earthing. Reference Documents. How many earths? Earthing Issue...

Agenda. Earthing of Telecom Installations using Single Point Earthing. Reference Documents. How many earths? Earthing Issue... Earthing of Telecom Installations using Single Point Earthing R. Saji Kumar DGM (IT) O/o The Chief General Manager Trivandrum Agenda Reference Documents Earthing Issue & the Problems Earthing Principle

More information

METRIC LIGHTNING PROTECTION PRODUCTS

METRIC LIGHTNING PROTECTION PRODUCTS Section 11 Metric Description... Page # 11.1 Taper Pointed Air Rods, Air Terminals & Attachments...270 11.2 Saddles & Attachments...271-272 11.3 s...273-275 11.4 Attachments...276-279 11.5 Clamps...280

More information

Standard Prices for Generators 2010

Standard Prices for Generators 2010 Standard Prices for Generators 2010 Distribution System Operator ESB Networks Page 1 of 13 CONTENTS 1.0 Background...3 2.0 Standard Pricing Approach...3 Schedule of Charges for generators excluding VAT...6

More information

Click to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance

Click to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance Click to edit Master title style Click to edit Master title style Northern Powergrid Asset Recording Guidance Rules for ICP & IDNO Version 1.0 April 2017 Introduction Accurate records for all assets are

More information

RECORD GROUP NUMBER 156

RECORD GROUP NUMBER 156 DEPARTMENT OF MENTAL HEALTH AND MENTAL RETARDATION HOSPITAL AND SCHOOL FOR THE RETARDED ARLINGTON, TENN. BLUEPRINTS, 1965 RECORD GROUP NUMBER 156 Processed by: David R. Sowell Archival Technical Services

More information

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm 2 + 80mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of, 3C x95mm 2 +

More information

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables 21, rue d Artois, F-75008 PARIS AUCKLAND 2013 http : //www.cigre.org Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables Michael Krüger, Rene Hummel, Stefan Böhler, OMICRON Austria

More information

WITHDRAWN JULY Manual: Distribution Substation Manual (DSM) Section I: Introduction

WITHDRAWN JULY Manual: Distribution Substation Manual (DSM) Section I: Introduction Manual: Distribution Substation Manual (DSM) Section I: Introduction Standard Number: HPC-5DA-07-0010-2012 Document Control Author Name: Viswa Easwaran Position: Standards Engineer Document Owner Name:

More information

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology Condition Assessment of High Voltage Insulation in Power System Equipment R.E. James and Q. Su The Institution of Engineering and Technology Contents Preface xi 1 Introduction 1 1.1 Interconnection of

More information

HOENER ASSOCIATES INC. ARCHITECTS

HOENER ASSOCIATES INC. ARCHITECTS HOENER ASSOCIATES INC. ARCHITECTS BRUCE D. DELL MARK REUTHER ADDENDUM NO. 1 PROJECT 15-22C RENOVATION AND SITE WORK AT: BUILDING B DDRB OF ST. CHARLES DEVELOPMENT DISABILITIES RESOURCE BOARD ST. CHARLES,

More information

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES 1. Qualifying Requirement of AB Cable Manufacture/Supplier The manufacturer should have manufactured, successfully type tested

More information

kv AC substation

kv AC substation 132-400 kv AC substation Outdoor AC substations Earthing systems ETS-50-08-01, Rev. 0 technical standard Document no. 13/90592-127 ETS-50-08-01 v. 0 REVISION VIEW Document no.: 13/90592-127 Version Author

More information

Quality Control Checklist - Design Drawings

Quality Control Checklist - Design Drawings Quality Control Checklist - Design Drawings Date Company Name Address Telephone Fax Email Job Number 1) Drawing Set a) Drawing one is site/location/incoming power i) Should contain location map if not

More information

CONTROL & RELAY PANEL

CONTROL & RELAY PANEL CONTROL & RELAY PANEL March 2015 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN: U40101WB2007SGC113474;

More information

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- 0005/ DMRC-E-TR-TRANSF-05 SPECIFICATIONS FOR THREE PHASE 33 kv/415 V AUXILIARY Issued on: Date

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 1. Introduction Fault location on communication and power cables

More information

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION December 2016 SPECIFICATION 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION

More information

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

TYPICAL PATIO COVERS.  OWNER: ADDRESS: PHONE: City of Aliso Viejo Building Division 12 Journey, Suite 100 Aliso Viejo, CA 92656 (949)425-2540 Fax (949)425-3899 www.cityofalisoviejo.com TYPICAL PATIO COVERS 111 I. GENERAL Patio covers are one-story,

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

General Technical Specifications of Frequency Converters for Tokyo-Chubu Interconnection Project

General Technical Specifications of Frequency Converters for Tokyo-Chubu Interconnection Project General Technical Specifications of Converters for Tokyo-Chubu Interconnection Project Note: It is possible that the contents of these specifications may be changed according to our detailed studies. Present

More information

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic GENERAL SITE PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS Scope of work narrative Building code review Description of construction Documentation on drawings as List of applicable

More information

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for

More information

Introduction to Substation Design TADP 542

Introduction to Substation Design TADP 542 Introduction to Substation Design TADP 542 Distribution Substations- Drawings and Documentation Instructor: Richard Snell Transmission & Distribution Program Drawings Drawings are prime method for communicating

More information

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv HV SYSTEMS Prysmian HV Systems Product Range 66kV & 132 kv Prysmian HV Product Range Version: 06/10 The History of Cables 66kV Copper Conductor XLPE Insulated Cables Prysmian Cables & Systmes Ltd is part

More information

PARALLEL GROOVE CLAMPS

PARALLEL GROOVE CLAMPS PARALLEL GROOVE CLAMPS 06 6 PARALLEL GROOVE CLAMPS 95 Contents General... 96 Parallel groove clamp with serrated grooves, forged, for aluminium based conductors... 98 Parallel groove clamp for earthwires

More information

LIST OF IS STANDARDS FOR ELECTRICAL PROJECTS

LIST OF IS STANDARDS FOR ELECTRICAL PROJECTS SL NO. NAME OF SPECIFICATION IS 1 Specification for High-Voltage Alternating-Current Circuit-Breakers IS 13118 2 Guide for testing of circuit breakers with respect to out-of-phase switching IS 9135 3 Bushings

More information

EH27401 Communication and Control in Electric Power Systems Lecture 2. Lars Nordström

EH27401 Communication and Control in Electric Power Systems Lecture 2. Lars Nordström EH27401 Communication and Control in Electric Power Systems Lecture 2 Lars Nordström larsn@ics.kth.se 1 Course map 2 Outline 1. Power System Topologies Transmission Grids vs Distribution grids Radial grids

More information

DA - DISTRIBUTION AUTOMATION

DA - DISTRIBUTION AUTOMATION DA - DISTRIBUTION AUTOMATION DA Drawing & CU Revision List CU DATE REVISION OF REVISION DA5_RM6 DA6_RM6 DA6_RM6_T200 DA6_RM6_T200 DA6_RM6_T200 DA1 DA2 DA3 DA4 DA3_150MHZ DA3_450MHZ Sept 2002 July 2006

More information

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED XLPE CABLE (33KV) September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN: U40101WB2007SGC113474;

More information

Kerman & Kavian Cable Industries ( KCI )

Kerman & Kavian Cable Industries ( KCI ) KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman

More information

WINTER 15 EXAMINATIONS Subject Code: Model Answer- Building Drawing Page No- 01 /15

WINTER 15 EXAMINATIONS Subject Code: Model Answer- Building Drawing Page No- 01 /15 Subject Code: 17309 Model Answer- Building Drawing Page No- 01 /15 Important Instruction to Examiners:- 1) The answers should be examined by key words & not as word to word as given in the model answers

More information

REGENCY TIMBER BUILDINGS

REGENCY TIMBER BUILDINGS REGENCY TIMBER BUILDINGS TEL 01948 830460 UNIT 22 PENLEY IND EST, PENLEY.WREXHAM. LL13 0LQ 1 Garage fitting instructions Tools needed handsaw, hammer, Stanley knife with hook blade, tape measure, battery

More information

Collection of standards in electronic format (PDF) 1. Copyright

Collection of standards in electronic format (PDF) 1. Copyright Collection of standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance

More information

REPORT OF PERFORMANCE TIC

REPORT OF PERFORMANCE TIC REPORT OF PERFORMANCE TIC 1580-13 OBJECT TYPE Three-core power cable 18/30(36) kv, 3x500 mm2, 2XWY(P)-FR XLPE Rated voltage, U 0/U (U m) 18/30 (36) kv Conductor material Cu Conductor cross-section 3x500

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge The University of New South Wales School of Electrical Engineering and Telecommunications High Voltage Systems ELEC9712 Appendix Partial Discharge Content Introduction Quantities measured Test circuits

More information

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General SECTION 26 01 00 ELECTRICAL GENERAL PART 1: GENERAL 1.1 Electrical/Telecommunications Design 1.1.1 This section of the design and construction standard outlines general requirements for electrical and

More information

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations Version: 3.1 Date of Issue: September 2016 Page: 1 of 21 NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations 1. Purpose The purpose of this document is to detail the technical requirements

More information

Lecturer: Dr. J B E AL-ATRASH No. of Pages: 4

Lecturer: Dr. J B E AL-ATRASH No. of Pages: 4 Philadelphia University Faculty of Engineering Dept. of Electrical Engineering Student Name: Student Number: Final Exam Course Title: Design of T&D System Date: 15 th June 2016 Course No: 610 515/650511

More information

RESTORATION OF DAVID SASSOON LIBRARY AND READING ROOM

RESTORATION OF DAVID SASSOON LIBRARY AND READING ROOM RESTORATION OF DAVID SASSOON LIBRARY AND READING ROOM 2005-2006 1.1 Enabling Works The enabling works include erecting scaffolding on the external of the facades and all around the clock tower for roof

More information

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

11-SDMS-03 REV. 02 SPECIFICATIONS FOR 11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice

More information

BP Brine Pro Brine Maker. Parts List. This Parts List is for BP-2000 brine makers with serial numbers beginning with and higher.

BP Brine Pro Brine Maker. Parts List. This Parts List is for BP-2000 brine makers with serial numbers beginning with and higher. November, 0 Lit. No., Rev. 0 BP-000 Brine Pro Brine Maker Parts List This Parts List is for BP-000 brine makers with serial numbers beginning with 00 and higher. A DIVISION OF DOUGLAS DYNAMICS, LLC FRAME

More information

SYARIKAT BEKALAN AIR SELANGOR SDN BHD

SYARIKAT BEKALAN AIR SELANGOR SDN BHD NOTE : 1. FOR LEGEND, ABBREVIATION AND GENERAL NOTES SEE DRG. NO. SYA / STD / 001. 2. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED. 3. ACTUAL LENGTH OF PE COMMUNICATION PIPES SHALL BE DETERMINED ON

More information

WEBS-MT/R Tower Installation Instructions

WEBS-MT/R Tower Installation Instructions I. Introduction This manual is for tower installation only. For instructions on installing the anchor bolts into the foundation, see the ETP-MT/R Anchor Bolt Installation Instructions. II. Contents Before

More information

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum. FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared

More information

G. KOEPPL Koeppl Power Experts Switzerland

G. KOEPPL Koeppl Power Experts Switzerland PS3: Substation Design: New Solutions and Experiences Bus-Node Substation A Big Improvement in Short-Circuit and Switching Properties at Reduced Substation Costs G. KOEPPL Koeppl Power Experts Switzerland

More information

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards. 8.3 Induced Voltage Purpose The purpose of this instruction is to provide awareness of Electrostatic and Electromagnetic induced voltages and the method required to reduce or eliminate it. An induced voltage

More information

Panels, Panel Mounting & Other Accessories

Panels, Panel Mounting & Other Accessories Panels, Panel Mounting & Other Accessories Wire mesh guarding on assembly conveyor line Machine safety enclosure using Lexan panels 108 Multiblock Al 1-105 1-3 Various fastening options for panels on Multiblock

More information

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e Download 12,000 More Shed Plans Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,

More information

Premoulded cable joint SMPGB

Premoulded cable joint SMPGB Premoulded cable joint SMPGB 362-420 Premoulded for safe and easy installation Active pressure Reliable Joint bodies routinetested according to IEC before delivery Bolt connector technology Compact joint

More information

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER TECHNICAL SPECIFICATION FOR POWER TRANSFORMER NOTE: Vendor to give their offer in line with this data sheet only. Any deviations/additions/deletions shall be brought out in a separate sheet. A TECHNICAL

More information

Cable Data Collector (CDC): Application Guide

Cable Data Collector (CDC): Application Guide Cable Data Collector (CDC): Application Guide Contents 1. Introduction... 1 2. PD in cables... 1 3. Principle of operation... 2 4. Advantages and disadvantages... 6 5. Assessing circuit suitability...

More information

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another. TRANSMISSION LINES PRELIMINARIES Generators and loads are connected together through transmission lines transporting electric power from one place to another. Transmission line must, therefore, take power

More information

MV Power Cable Testing Training

MV Power Cable Testing Training MV Power Cable Testing Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq Since power cables are used

More information

Temperature Sensor model TS-1/PS

Temperature Sensor model TS-1/PS Description The Sine Systems model TS-1/PS Temperature allows remote monitoring of indoor or outdoor temperature with the RFC-1 Remote Facilities Controller. The TS-1 is the temperature sensor. Model TS-1/PS

More information

Electric cables. Cranes

Electric cables. Cranes Electric cables. Cranes Electric cables for mobile connections. Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 01/2012 Copyright Drawings and technical descriptions

More information

8 x 10 Timber-frame Garden Shed

8 x 10 Timber-frame Garden Shed 8 x 10 Timber-frame Garden Shed Includes: Step-By-Step Instructions, Complete Details & Materials Lists Timber-framing is a traditional building method that uses a simple framework of heavy timber posts

More information

WEBS-MT/R Tower Installation Instructions

WEBS-MT/R Tower Installation Instructions I. Introduction This manual is for tower installation only. For instructions on installing the anchor bolts into the foundation, see the ETP-MT/R Anchor Bolt Installation Instructions. II. Contents Before

More information

NATIONAL INSTITUTE OF NUTRITION, HYDERABAD (UPGRADATION OF EXTERNAL ELECTRICAL WORKS)

NATIONAL INSTITUTE OF NUTRITION, HYDERABAD (UPGRADATION OF EXTERNAL ELECTRICAL WORKS) TENDER BOQ (APPROXIMATE)- PRICE BID FOR EXTERNAL ELECTRICAL WORKS (NIN, TARNAKA) NOTE: 1 THE PARTICIPANTS/BIDDERS SHALL MANDATORILY SUBMIT THEIR QUOTES FOR ALL THE WORKS viz. SUPPLY OF TRANSFORMERS, DG

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts ALPHA AS Modular Distribution Boards /2 Introduction Unequipped Distribution Boards /4 Modular distribution boards / Add-on parts Assembly Kits for Unequipped Distribution Boards /6 8GK4 assembly kits

More information

Substation: From the Outside Looking In.

Substation: From the Outside Looking In. 1 Substation: From the Outside Looking In. Moderator n Ron Spataro AVO Training Institute Marketing Manager 2 Q&A n Send us your questions and comments during the presentation 3 Today s Presenter n Greg

More information

General Requirements. Technical Specification LVAC Systems

General Requirements. Technical Specification LVAC Systems Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks LVAC Systems NO: 423-1

More information

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL GROUP OF COMPANIES MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL Revision 1.5 23 February 2007 : INSTALLERS MANUAL Table of Contents 2 INTRODUCTION.. 3 INSTALLER OPTIONS...... 4-11 ALARM SETTING

More information

E S T I M A T E Name of Work : Estimate of Electric & Air Conditioned Work for Union Bank of India, Saral Branch, Dist. Rajkot.

E S T I M A T E Name of Work : Estimate of Electric & Air Conditioned Work for Union Bank of India, Saral Branch, Dist. Rajkot. E S T I M A T E Name of Work : Estimate of Electric & Air Conditioned Work for Union Bank of India, Saral Branch, Dist. Rajkot. It. No. Quantity Unit PART- III - ELECTRIC WORK:- 1.0.0 Supply, installation,

More information

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED Dial : (033)2677-5835 & 2667-8358 Tele Fax : (033)2667-8358 Manufacturer of Dry Type Transformers E-mail : unimag111@gmail.com Office & Factory : 26/5, Sarat Chatterjee Road, Howrah 711 104, West Bengal,

More information

Complex Solution for the Distribution Substation REF 542plus. Application and Setting Guide

Complex Solution for the Distribution Substation REF 542plus. Application and Setting Guide Complex Solution for the Distribution Substation REF 542plus 1MRS756412 Complex Solution for the Distribution Substation REF 542plus Copyrights The information in this document is subject to change without

More information