1 Selecting the right float switch 2 There are different methods for selecting the right float switch for a particular application. This note suggests one such method. 1. Physical arrangement and choice of float switch style. The choice of styles that may be suitable for an application will depend on the physical arrangement of the tank, the available mounting positions and whether access is available to the inside of the tank. Consideration should also be given to whether there is the possibility of a build up of deposits, from the liquid, on the float body. These deposits can, over a period of time, accumulate to such an extent that the float switch can fail to operate. There are particular series designed to limit the effects of this build up. There are also choices, for some series, of mounting thread. 2. Material selection The selection of most suitable materials, for float switch and gasket, can be made by reference to the Chemical Compatibility chart ( This gives a good indication of the suitability, of the float switch materials, in a wide range of liquids. It may be necessary, for some liquids, to obtain a sample float switch to test the compatibility. 3. Electrical It is important to fully understand the nature of the load, to be switched by the float switch, and to make sure that the switch is capable of handling this load. The electrical ratings, shown in Crydom float switch specifications, are all for purely resistive loads. Any loads that have either inductive or capacitive components should have the appropriate contact protection measure applied, by reference to the Circuit Hazards and Contact Protection ( application note. 4. Cables Crydom has standard, UL approved, cable types for the various float switches, which are shown on the product data sheets. Other cables, or connectors, can be supplied subject to special quotation and order. 5. Options Crydom has, over the years, produced many variants of its float switches to match particular customer requirements. Please contact Technical Support for advise about any particular special requirement

2 13 SLP4 Submersible level probe Submersible probe Low space requirement Cable mounted N/O or N/C configurable No power requirement This is a single switch point liquid level probe, for use in water or acqueous liquids, designed to be suspended into the liquid by its cable. It can be configured to give make or break action on either rise or fall, by removing the protective shield and reversing the float orientation. The switching level may be adjusted by varying the cable length. The reedswitch contact is suitable for switching signal levels, up to 50 volts. The main uses for this probe are level switch for narrow boreholes, or applications with restricted space, and also as a signal switch for reservoir high or low level monitoring. These are manufactured with standard PVC cable lengths of 15 or 25 metres but can be manufactured with other lengths. Other switch types and configurations, cable gland and cable type are possible, please contact Crydom with your requirement. TECHNICAL SPECIFICATIONS Float Polypropylene Housing Stainless Steel Shield Stainless Steel Cable gland Nylon Cable 2 core PVC sheathed Cable length 15M 25M Temp. Range C -20 / +75 F -4 / +167 Min. Fluid S.G. 0.8 Max working pressure 5 bar ELECTRICAL SPECIFICATIONS Contact Form N/O (N/C) VA Rating Max. 25 Switching Voltage AC/DC Max. 50 Switching Current Max. A 0.6 All ratings are for resistive load only Crydom no. SLP4AP15 SLP4AP25 Cable length 15 metres 25 metres OUTLINE DIMENSIONS Cable 2 Core PVC Cable Gland: IP68 CONTACT US NOW UNITED KINGDOM CRYDOM T F E W T F E W +44 (0) (0) magnetics@crydom.com USA CRYDOM sales@crydom.com Nom Nom. Body: Stainless Steel Float Shield: Stainless Steel Perforated Float Switch: Polypropylene SLP4 Submersible level probe

3 FFS Series The FFS series of cable end float switches are designed for controlling levels in large tanks, cisterns or reservoirs and can be directly installed on submersible pumps. The casing is manufactured in blow moulded Polyethylene (PEHD), with 5m PVC cable with protective earth conductor as standard. The switching element is a microswitch, with UL, VDE and CENELEC approvals, activated by a moving stainless steel ball and having an electrical life of 200,000 operations. Non hygroscopic closed cell expanded polyurethane is injected around the switch housing within the outer casing, hermetically sealing the unit. It is capable of working down to 100 metres depth in water. 14 Other models, including versions for use in fuel oils, are available. Please contact our sales office for details. Technical Specifications FFS10A FFS10B FFS10C FFS20A FFS20B FFS20C Contact Form A B C A B C Material MECHANICAL 83.0 O 52.0 Adjustable Counterweight/Pivot Min Pivot Length 120mm High Density Polyethylene Temp Range C 0 / +55 F + 32 / +131 Standard cable PVC (Length 5m) U cable option for Fuel oils Max. working pressure Electrical Specifications Polyurethane 10 bar Power Rating AC : 750 VA DC : 180W AC : 1500 VA DC : 360W Switching Voltage AC : 250 V DC : 110 V AC : 250 V DC : 110 V Switching Current Max. Resistive 10 A 20 A Switching Current Max. Inductive AC : 4A DC : 1 A AC : 8A DC : 2 A Direct power switching Cable mounting 100 metre depth capability ON - OFF Differential 61.0 OFF - ON FFS Series

4 15 FFS Series WRAS APPROVED Direct power switching Cable mounting WRAS Approved 100 metre depth Capability These switches are manufactured with an outer case of blow moulded PEHD (High Density Polyethylene) and an intermediate filling of non-hygroscopic closed cell polyurethane foam around a sealed switch housing. They can be supplied with either make on rise (N/O), make on fall (N/C) or change over (C/O) switching action. The N/O and N/C versions have an earth protection wire within the 5 metre cable, which can be either PVC (for general purpose applications) or WRAS approved (for drinking water applications). External counterwights are supplied to adjust the pivot position. Contact Crydom for other cable types and lengths. Material Specifications Body Material High Density Polyethylene Cable sheath material PVC or WRC approved Cable length 5 metres standard (10 to 100 optional) Temperature range C 0 to 55 C F + 32 / +131 Max. working pressure 10 bar Technical Specifications Switching element 10 Amp 20 Amp Max power DC 750VA/AC DC 750VA/AC 180W 360W Switching Current Max. Resistive 10A 20A Switching Current Max. Inductive DC 1A / AC4AC DC 2A/AC8A Switching Voltage Max. DC 110 / AC250 DC 110/250 INSTALLATION cable entrance cable CONTACT US NOW UNITED KINGDOM CRYDOM T F E W T F E W +44 (0) (0) magnetics@crydom.com USA CRYDOM sales@crydom.com wiring diagram for filling pump external counterweight differential pipe wiring diagram for emptying pump tie FFS Series WRAS APPROVED

5 FFSMC Multi-contact float switch Submerged type float switch for sewer and industrial waste systems. This self-weighted cable end float switch is designed for use in turbulent industrial fluids and fluids with suspended agglomerates, such as sewer water. The switch is water resistant up to a depth of 100m, and is insensitive to humidity and condensation, due to the particular design of the switch element. This makes it suitable for applications where there may be wide or rapid fluctuations in ambient or fluid temperatures. Switching capacity of this new design of self-cleaning switch element is 10A at 250V ac. The outer casing is manufactured in blow moulded Polyethylene (PEHD) and the switch element is surrounded by non-hygroscopic closed cell expanded polyurethane, hermetically sealing the unit. The switch is fitted with an internal weight such that it fixes the centre of gravity, and rotation, close to the cable entry. An external counterweight is supplied to adjust the pivot position. The moulding shape is rounded to prevent the accumulation of solids, that could cause the float to sink. Technical Specifications FFSMC10A FFSMC10B FFSMC10C Contact Form A B C Material High Density Polyethylene Temp Range C 0 / +55 F + 32 / +131 Cable (standard length 5m) With protective earth no earth Standard cable covering PVC U cable option for Fuel oils Polyurethane Max. working pressure 10 bar Electrical Specifications Power Rating AC : 750 VA DC : 180W Switching Voltage AC : 250 V DC : 110 V Switching Current Max. Resistive 10 A Switching Current Max. Inductive AC : 4A DC : 1 A It is necessary to use an auxiliary relay, when switching pump motors or any loads that are not purely resistive. MECHANICAL Model for diesel oil Operates in Turbulent Fluids Unaffected by Suspended Solids Cable Mounting 100m Depth Capability Model for sewer water Off - On Differential On - Off FFSMC Multi-contact float switch

6 17 FFSMC Multi-contact float switch Part Numbering System Series Max. current Contact Form A = n/o B = n/c C = c/o Installation FFSMC 10 A U 1000 Cable length in cms: Blank = 5M standard Cable covering: Blank = PVC U = Polyurethane N = Neoprene S = Silicone cable entrance cable external counterweight differential tie pipe wiring diagram for filling pump wiring diagram for emptying pump FFSMC Multi-contact float switch

7 FFSMC Series WRAS APPROVED Submerged type float switch for reservoir and industrial waste water systems. This self-weighted cable end float switch is designed for use in turbulent water and water with suspended agglomerates, such as sewer water. The switch is water resistant up to a depth of 100m, and is insensitive to humidity and condensation, due to the particular design of the switch element. This makes it suitable for applications where there may be wide or rapid fluctuations in ambient or water temperatures. Switching capacity of this new design of self-cleaning switch element is 10A at 250V ac. The outer casing is manufactured in blow moulded Polyethylene (PEHD) and the switch element is surrounded by non-hygroscopic closed cell expanded polyurethane, hermetically sealing the unit. The switch is fitted with an internal weight such that it fixes the centre of gravity, and rotation, close to the cable entry. An external counterweight is supplied to adjust the pivot position. The moulding shape is rounded to prevent the accumulation of solids, that could cause the float to sink. Technical Specifications Crydom part FFSMC10AW FFSMC10BW FFSMC10CW Contact Form N/O N/C C/O Switching Current Max. Resistive 10 A Switching Current Max. Inductive AC 4A DC 1A Power Rating AC VA 750 DC W 180 Switching Voltage AC V 250 DC V 110 Cable Material WRC approved PVC Cable length Standard length 5 metres Body Material High Density Polyethylene Temperature Range C 0 / +55 F + 32 / +131 Max. working pressure bar 10 It is necessary to use an auxiliary relay, when switching pump motors or any loads that are not purely resistive. MECHANICAL Off - On Differential On - Off 190 Model for diesel oil Operates in Turbulent Fluids Unaffected by Suspended Solids WRAS approved Cable Mounting 100m Depth Capability Model for sewer water FFSMC Multi-contact float switch

8 19 FFSMC Series WRAS APPROVED Part Numbering System Series Max. current Contact Form A = n/o B = n/c C = c/o FFSMC 10 A U 1000 Cable length in cms: Blank = 5M standard Cable covering: Blank = PVC U = Polyurethane N = Neoprene S = Silicone Installation cable entrance cable external counterweight differential tie pipe wiring diagram for filling pump wiring diagram for emptying pump FFSMC Multi-contact float switch

9 LM10 series This is suitable for use in water, industrial wastewater and sewage, that can have wide variations of temperature. This small design of switch is for use in more confined spaces, where there is not enough room for the larger FFSMC type. The rounded body design and floating attitude prevents accumulation of solids on the body. The switch has additional internal ballast, to bring the centre of gravity and rotation close to the cable entry point. The switching element is a self cleaning type, that makes the complete switch insensitive to humidity and condensation, allowing this type to operate in widely fluctuating temperatures. The switch contacts are rated at 10 Amp resistive. Supplied, as standard, with 5 metres cable and adjustable counterweight. Technical Specifications LM10A LM10B LM10C Contact Form N/O N/C C/O Material High Density Polyethylene Temp Range C 0 / +55 F + 32 / +131 Cable (standard length 5m) With protective earth no earth Standard cable covering PVC U cable option for Fuel oils Polyurethane Max. working pressure 10 bar Electrical Specifications Power Rating AC : 750 VA DC : 180W Switching Voltage AC : 250 V DC : 110 V Switching Current Max. Resistive 10 A Switching Current Max. Inductive AC : 4A DC : 1 A It is necessary to use an auxiliary relay, when switching pump motors or any loads that are not purely resistive. MECHANICAL Minimum Cable Pivot length 120mm Off - On Differential On - Off For smaller tanks and restricted space Use in sewer and industrial waste water Shape avoids ragging, in sewer systems Unaffected by suspended solids Operates in Turbulent Fluids LM10 Series

10 21 LM10 series Part Numbering System Series Max. current Contact Form A = n/o B = n/c C = c/o Installation LM 10 A U 10 Cable length in mtrs: Blank = 5M standard Cable covering: Blank = PVC U = Polyurethane N = Neoprene S = Silicone cable entrance cable differential external counterweight tie pipe wiring diagram for filling pump wiring diagram for emptying pump LM10 Series

11 General Container wall thickness and ease of access must be determined in order to select the fitting type required. The tank wall should be flat, as concave or convex walls can cause ineffective sealing of the float switch into the tank wall. application notes 22 Hold the float switch firmly, ensuring that the orientation of the float is correct and that the sealing washer/gasket is not impaired, and tighten the fixing nut, until finger tight. Carefully tighten the fixing nut to the appropriate torque of 3.0lbs/fl. (4.0Nm) maximum. Check the seal and orientation, before connecting the float switch to the required electrical circuit. Please note that fixing nuts should not be overtightened, as this may damage the product. Maximum wall thickness should not be exceeded or leaking may occur. Gasket Seal Nylon Nut Drill the correct size hole in the tank wall, observing the appropriate safety requirements. Remove any swarf and ensure that both faces of the hole are smooth, to avoid damage to the sealing washer/gasket. Internal fitting types, RSF10, RSF20, RSF30, RSF40, RSF50, RSF60 series. Fit the sealing washer/gasket to the float switch thread. Feed the connecting lead through the hole in the container, from the inside. Take care to ensure that the sealing washer gasket is not damaged and that it is correctly positioned against the inside face of the tank wall and the collar of the float switch. External fitting RSF70 series. Feed the compression seal/grommet, friction relief washer and fixing nut over the connecting leads and position on the float switch thread, ready for tightening. M16x2 Thread Nylon Nut Nylon Washer Compression seal for External Mount Turn the fixing nut only until the compression seal/grommet starts to deform. Hold the float switch assembly by the cable entry end and insert the assembly into the hole in the tank wall until the compression seal/grommet meets the face of the tank wall. Ensure orientation of the float switch is correct, by reference to the indicator at the cable entry. Tank Wall Gasket Seal container Feed the fixing nut over the connecting leads and position on the float switch thread, ready for tightening. Push float through tank wall Hold the float switch assembly by the cable entry end, using the flats provided, and carefully tighten the fixing nut to a maximum torque of 2.0 lbs/ft. (2.67Nm). Check the seal and orientation, before connecting the float switch to the required electrical circuit. Gasket Seal Nylon Nut Tank Wall Hold the float switch firmly, ensuring that the orientation of the float is correct and that the sealing washer/gasket is not impaired, and tighten the fixing nut, until finger tight. Compressed seal

12 23 External fitting type RSF80 series. This type has a ½ NPT taper thread, which can be screwed directly into a ½ BSP female thread, to provide a jam fit, or into a ½ NPT taper female thread. The tank wall, or tank wall and threaded boss, should have a minimum threaded length of 7mm and a maximum length, from the outer thread to the inner face of the tank wall, of 17mm. Thick Wall Threaded Boss Apply a compatible sealing compound, or tape, to the thread, from the outside of the tank, and rotate the assembly until it is finger tight in the thread. Tighten the assembly into the thread, using a spanner on the flats provided, until a good seal is make and the orientation of the assembly is correct (marker on cable entre end), ensuring the torque is limited to less than 5.0 lbs/ft. (6.75 Nm). Thin Wall Drill a hole in tank wall of the correct size for cutting the required thread form, or drill a hole and fit a threaded boss on or in the wall of the tank. NPT into NPT ½" NPT Taper Thread (Will fit 1/2" BSP) NPT into BSP

13 24 Installation instructions for Crydom float switches General Container wall thickness and ease of access must be determined in order to select the fitting type required. The tank wall should be flat, as concave or convex walls can cause ineffective sealing of the float switch into the tank wall. Please note that fixing nuts should not be overtightened, as this may damage the product. Maximum wall thickness should not be exceeded or leaking may occur.drill the correct size hole in the tank wall, observing the appropriate safety requirements. Remove any swarf and ensure that both faces of the hole are smooth, to avoid damage to the sealing washer/gasket. Internal fitting types, RSF10, RSF20, RSF30, RSF40, RSF50, RSF60 series Fit the sealing washer/gasket to the float switch thread. Feed the connecting lead through the hole in the container, from the inside. Take care to ensure that the sealing washer/gasket is not damaged and that it is correctly positioned against the inside face of the tank wall and the collar of the float switch. Feed the fixing nut over the connecting leads and position on the float switch thread, ready for tightening. Hold the float switch firmly, ensuring that the orientation of the float is correct and that the sealing washer/gasket is not impaired, and tighten the fixing nut, until finger tight. Carefully tighten the fixing nut to the appropriate torque of 3.0lbs/ft. (4.0Nm) maximum. Check the seal and orientation, before connecting the float switch to the required electrical circuit. External fitting RSF70 series Feed the compression seal/grommet, friction relief washer and fixing nut over the connecting leads and position on the float switch thread, ready for tightening. Turn the fixing nut only until the compression seal/grommet starts to deform. Hold the float switch assembly by the cable entry end and insert the assembly into the hole in the tank wall until the compression seal/grommet meets the face of the tank wall. Ensure orientation of the float switch is correct, by reference to the indicator at the cable entry. Hold the float switch assembly by the cable entry end, using the flats provided, and carefully tighten the fixing nut to a maximum torque of 2.0 lbs/ft. (2.67Nm). Check the seal and orientation, before connecting the float switch to the required electrical circuit. External fitting type RSF80 This type has a ½" NPT taper thread, which can be screwed directly into a ½" BSP female thread, to provide a "jam" fit, or into a ½" NPT taper female thread. The tank wall, or tank wall and threaded boss, should have a minimum threaded length of 7mm and a maximum length, from the outer thread to the inner face of the tank wall, of 17mm. Drill a hole in tank wall of the correct size for cutting the required thread form, or drill a hole and fit a threaded boss on or in the wall of the tank. Apply a sealing compound, or tape, to the thread of the float switch. Insert the float switch into the thread, from the outside of the tank, and rotate the assembly until it is finger tight in the thread. Tighten the assembly into the thread, using a spanner on the flats provided, until a good seal is made and the orientation of the assembly is correct (marker on cable entry end), ensuring the torque is limited to less than 5.0 lbs/ft. (6.75 Nm)

14 Crydom Float Switch Selector Chemicals Printed 24/06/2004 Classification Chemical PVC Nylon Polypropylene Polysulfone* PPS Viton Nitrile Silicone Organic Chemicals Acetaldehyde E5 C3 C4 - A1 E5 E5 C3 Acids - Organic Acetic Acid, concentrated (glacial) E5 E5 A2 B4 A1 D4 D5 B5 Acids - Organic Acetic Acid, dilute A2 E5 A1 B3 A1 D4 C5 B3 Organic Chemicals Acetone (Dimethyl Ketone) E5 A2 A1 D5 A1 D4 E5 C4 Alkalis Ammonia, Aqueous, dilute A2 C5 A1 A2 B2 B2 D5 B2 Alkalis Ammonium Hydroxide, concentrated B2 E5 A1 A2 D5 C3 E5 B2 Organic Chemicals Amyl Acetate E5 B3 C4 - A1 E5 E5 B2 Organic Chemicals Aniline E5 D5 A2 - A1 B4 E5 B2 Foodstuffs Beer A2 A1 A1 - - A1 A1 A1 Organic Chemicals Benzene E5 B2 C4 D5 A1 D4 E5 E5 Misc Bleach D4 C4 B3 B3 A1 E5 C5 B3 Alcohols Butanol (Butyl Alcohol) C5 C3 A1 B3 A1 - A- D5 Inorganic Chemicals Calcium Hypochlorite D5 E5 B3 B3 B2 E5 E5 B3 Organic Chemicals Cellosolve (2-Ethoxy Ethanol) E5 - - B3 A1 - C- - Organic Chemicals Chloroform E5 C5 D5 E5 D5 D5 E5 E5 Acids - Organic Citric Acid A2 C5 A1 A2 A1 A1 A1 A1 Inorganic Chemicals Copper Nitrate A2 A1 A1 - A1 A1 A2 A1 Inorganic Chemicals Copper Sulphate A2 A1 A1 - A1 A1 A2 A1 Organic Chemicals Cyclohexane E5 A2 E5 B3 A1 D5 A1 E5 Misc Detergents B2 B3 A1 B2 A1 B2 A1 A1 Fuels / Oils Diesel - A2 C5 B2 A1 B2 A1 D5 Organic Chemicals Dimethyl Phthalate E D5 - E5 - Fuels / Oils Engine Oil - A2 A2 B3 A1 D5 B2 B3 Alcohols Ethanol (Ethyl Alcohol) B4 C3 A1 B3 A1 B2 A- C4 Organic Chemicals Ethyl Acetate E5 A1 B2 E5 A1 E5 E5 E5 Organic Chemicals Ethylene Glycol (Antifreeze) A2 B3 A1 B3 A1 B3 A1 A1 Inorganic Chemicals Ferric Chloride A2 D5 A1 - A1 A1 A1 A1 Organic Chemicals Formaldehyde (Formalin) B4 B3 A1 D5 A1 B3 C5 A1 Acids - Organic Formic Acid (Methanoic Acid) C3 E5 A1 B3 A1 E5 C5 B5 Foodstuffs Fruit Juice A2 A1 A1 - A1 A1 A1 A1 Organic Chemicals Glycerol (Glycerin) A2 B4 A1 B3 A1 A1 A1 A1 Fuels / Oils Hydraulic Fluid B- A1 B- A- - Acids - Inorganic Hydrochloric Acid, concentrated A2 E5 B4 A1 C4 B2 C5 E5 Acids - Inorganic Hydrochloric Acid, dilute B2 C5 B2 A1 B3 A1 B4 C5 Acids - Inorganic Hydrofluoric Acid E5 E5 E5 D5 E5 B2 E5 E5 Inorganic Chemicals Hydrogen Peroxide, Concentrated A2 E5 A5 B4 E5 B4 E5 B2 Inorganic Chemicals Hydrogen Peroxide, dilute A2 E5 A2 B4 E5 B3 D5 A1 Fuels / Oils Kerosene (Aviation Fuel) C4 A2 C4 C5 A1 A1 A- - Acids - Organic Lactic Acid C4 B3 A1 B3 A1 C5 B4 A1 Fuels / Oils Lubricating Oil - A2 A2 B2 A1 - B2 D5 Alcohols Methanol (Methyl Alcohol) C4 C4 A1 C4 A1 C4 A1 B3 Organic Chemicals Methyl Ethyl Ketone (MEK) E5 B3 B4 D5 D5 E5 E5 E5 Organic Chemicals Methylene Chloride E5 D5 D5 E5 D5 E5 E5 E5 Page 1 Crydom Magnetics Ltd

15 Crydom Float Switch Selector Chemicals Printed 24/06/2004 Classification Chemical PVC Nylon Polypropylene Polysulfone* PPS Viton Nitrile Silicone Fuels / Oils Mineral Oil / Fuel Oil B4 A2 A2 B3 A1 A2 A2 B3 Acids - Inorganic Nitric Acid, concentrated C5 E5 C5 E5 E5 D5 E5 E5 Acids - Inorganic Nitric Acid, dilute B5 E5 A1 C5 C4 C5 D5 D4 Organic Chemicals Nitrobenzene E5 D5 A1 - A1 A1 E5 E5 Organic Chemicals Nitromethane - A2 - - A1 - E5 - Foodstuffs Olive Oil A2 B2 A1 - - C4 A2 A2 Organic Chemicals Perchloroethylene E5 A1 B3 D- - Fuels / Oils Petrol (Gasoline) B4 A2 C4 B3 A1 B2 A2 D5 Acids - Inorganic Phosphoric Acid, concentrated A2 E5 A1 B2 A1 B3 D5 C4 Acids - Inorganic Phosphoric Acid, dilute A2 E5 A1 A2 A1 B2 C4 B2 Inorganic Chemicals Potassium Chloride A2 B3 A1 - A1 A1 A1 A1 Inorganic Chemicals Potassium Cyanide A2 - A1 - A1 - A- - Inorganic Chemicals Potassium Nitrate A2 A2 A1 A1 A1 A1 A1 A1 Alcohols Propanol (IPA) - - A1 B3 A1 C5 B- D5 Inorganic Chemicals Silver Nitrate A2 A2 A2 - A1 A1 B2 A1 Misc Soaps A2 B3 A1 B2 A1 - A1 - Inorganic Chemicals Sodium Bicarbonate A2 B3 A1 - A1 A1 A1 A1 Inorganic Chemicals Sodium Chloride A2 B3 A1 - A1 A1 A1 A1 Inorganic Chemicals Sodium Cyanide A2 - A1 - A1 - A- - Alkalis Sodium Hydroxide, concentrated A2 E5 A1 B3 C4 D5 C4 C4 Alkalis Sodium Hydroxide, dilute A2 C5 A1 A1 A1 D5 B3 B3 Inorganic Chemicals Sodium Nitrate A2 B3 A1 - A1 A1 A1 A1 Acids - Inorganic Sulphuric Acid, concentrated E5 E5 D5 D4 D5 A2 E5 E5 Acids - Inorganic Sulphuric Acid, dilute B3 E5 A2 C3 A1 A2 D5 C5 Organic Chemicals Toluene E5 A2 D4 D5 A1 E5 E5 E5 Organic Chemicals Trichloroethylene E5 A3 D4 E5 - D5 D5 E5 Misc Turpentine - - D4 B3 A1 D5 A- E5 Misc Urine A2 B3 A1 - A1 A1 A- A1 Foodstuffs Vegetable Oil B2 A2 A1 - A1 B2 A2 A2 Misc Water A2 B3 A1 B2 A1 A2 A1 A1 Foodstuffs Whiskey - - A A- - Foodstuffs Wine - - A A- - Organic Chemicals Xylene E5 A2 D4 D5 A1 E5 E5 E5 Page 2 Crydom Magnetics Ltd

Technical data sheet. 1. Manufacturer. 2. Product description. 3. Application areas. 4. Features. 5. Technical data

Technical data sheet. 1. Manufacturer. 2. Product description. 3. Application areas. 4. Features. 5. Technical data Technical data sheet 8 64 mm 1. Manufacturer Egli, Fischer & Co. Ltd. Gotthardstrasse 6 P.O. Box 8022 Zurich Switzerland 2. Product description One-piece, self locking plastic pipe clamp for the indoor

More information

SWITCHING THE SMART WAY. Reed Switches. SMD Reed Switches. Reed Sensors. Level Sensors. Hall Sensors. Magnets. Sensor Technology

SWITCHING THE SMART WAY. Reed Switches. SMD Reed Switches. Reed Sensors. Level Sensors. Hall Sensors. Magnets. Sensor Technology SWITCHING THE SMART WAY Reed Switches SMD Reed Switches Reed Sensors Level Sensors Hall Sensors Magnets Sensor Technology Welcome to PIC Our work is never done. Passion, respect, integrity and discipline

More information

Ansell Chemical Guardian Portal

Ansell Chemical Guardian Portal Ansell Chemical Guardian Portal Oct 16, 2017 Legend (min) < 10 Not Recommended 10-30 Splash Protection Permeation breakthrough times evaluate the time necessary for a chemical to pass through a glove material

More information

SWITCHING THE SMART WAY. Reed Switches. SMD Reed Switches. Reed Sensors. Level Sensors. Magnets. Sensor Technology

SWITCHING THE SMART WAY. Reed Switches. SMD Reed Switches. Reed Sensors. Level Sensors. Magnets. Sensor Technology SWITCHIG THE SMRT WY Reed Switches SMD Reed Switches Reed Sensors Level Sensors Magnets Sensor Technology Welcome to PIC Our work is never done. Passion, respect, integrity and discipline are the four

More information

TURCK Capacitive Sensors - Principles of Operation

TURCK Capacitive Sensors - Principles of Operation TURCK Capacitive Sensors - Principles of Operation Applications Liquid Level Control for both hazardous and non hazardous materials. Package Inspection for product content and/or fill level. Wire-Break

More information

Symprobe RF Capacitance Level Transmitter Model LP75 Owner s Manual

Symprobe RF Capacitance Level Transmitter Model LP75 Owner s Manual Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 1000 Humbolt Street Los Alamitos, CA 90720. If

More information

Symprobe RF Capacitance Level Transmitter Model LP75 Owner s Manual

Symprobe RF Capacitance Level Transmitter Model LP75 Owner s Manual Warranty, Service and Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: FLOWLINE Inc. 1000 Humbolt Street Los Alamitos, CA 90720 If

More information

Liquid level monitors and controls

Liquid level monitors and controls Liquid level monitors and controls ontent M-ENE, M-ENE MAX... / 8 M-ENS... / 83 M-ENS UP/DOWN... / 84 M-ENN... / 85 M-ENN UP/DOWN... / 86 Accessories for liquid level relays... / 87 Technical data M-ENE,

More information

Air-operated diaphragm pumps Type FDM

Air-operated diaphragm pumps Type FDM Air-operated diaphragm pumps Type FDM FLUX air-operated diaphragm pumps Type FDM genuine allrounders FLUX air-operated diaphragm pumps are genuine allrounders for the safe reliable and careful (no shearing)

More information

Repair Manual 12 PL PILOT

Repair Manual 12 PL PILOT Repair Manual 12 PL PILOT 12 PL PILOT REPAIR MANUAL INDEX Introduction... 1 Elastomer Materials... 2 Disassembly... 3 Assembly... 7 Testing... 11 NOTE: We reserve the right to modify or change, without

More information

Synergy RJ45 LCS 6 Category 6 data outlets

Synergy RJ45 LCS 6 Category 6 data outlets Legrand Electric Ltd. Arena Park - Dial Lane West Bromwich - West Midlands - B70 0EB- United Kingdom Technical enquiries : Tel. 0870 8 90 - Fax. 0870 8 9021 CONTENTS PAGE 7300 56 7300 57 1. Applications...

More information

Refractometer. MONITORED CHEMICALS Acetic acid CH 3

Refractometer. MONITORED CHEMICALS Acetic acid CH 3 Applications K-Patents Semicon Process Refractometer PR-33-S monitors real-time the consistency of liquid chemical concentrations in the ultra-clean semiconductor fabrication processes and integrated process

More information

50, 75, & 150 PG PILOT

50, 75, & 150 PG PILOT Repair Manual 50, 75, & 150 PG PILOT 50, 75, & 150 PG PILOT REPAIR MANUAL INDEX Introduction... 1 Elastomer Materials... 2 Disassembly... 3 Part Inspection... 6 Assembly... 7 Testing... 11 NOTE: We reserve

More information

special stepper motor

special stepper motor special stepper motor IP00 vacuum IP65 splash water IP68 underwater 1 / 8 www.igus.de MOT-XX-S_EN_201701#1 part number MOT XX S 060 007 056 M A AAAA specifics AAAK IP65 splash water AAAL IP65 splash water

More information

Top Chain U.S. TSUBAKI TOP CHAIN

Top Chain U.S. TSUBAKI TOP CHAIN U.S. TSUBAKI TOP CHAIN Top Chain U.S. Tsubaki Top chain is ideal for continuous conveying applications such as bottling, canning and packaging of beverages, food, drugs, chemicals and cosmetics, and for

More information

AF-4 Grooved Flange Adapter

AF-4 Grooved Flange Adapter SUBMITTAL INFORMATION PROJECT NAME: ENGINEER: CONTRACTOR: SPEC. SECTION: MEMBER FEATURES & ADVANTAGES Designed for connecting ANSI/AWWA C110/A21.10 and ASME/ANSI B16.1 Class 125/ flanged end components

More information

Physical Properties of

Physical Properties of Physical Properties of 2 ASTM Typical Value Property (a) Method (.236 Thickness) (b) Mechanical Specific Gravity D 792 1.19 Tensile Strength D 638 10,000 psi (69 M Pa) Elongation, Rupture 4.2% Modulus

More information

PMIS3 POSIMAG Magnetic Scale Position Sensor

PMIS3 POSIMAG Magnetic Scale Position Sensor PMIS3 POSIMAG Magnetic Scale Position Sensor Very compact sensor for industrial applications Sensor head PMIS3 Non-contact, no wear High velocity Robust shielded metal enclosure Protection class IP67 Incremental

More information

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34. MUELLER SMALL DRILLING MACHINES 2.1 Shaded area indicates change Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines

More information

CONDUCTIVE LEVEL PROBE

CONDUCTIVE LEVEL PROBE CONDUCTIVE LEVEL PROBE The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine

More information

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure. MUELLER SMALL DRILLING MACHINES 2.1 Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines are available in hand

More information

Chemical Compatibility Guide for: Tychem BR Suits

Chemical Compatibility Guide for: Tychem BR Suits Chemical Compatibility Guide for: Tychem BR Suits NOTICE: The guide on the following page(s) was provided by the supplier. New Pig Corporation assumes no responsibility, obligation, or liability in conjunction

More information

TOOLS AND INSTALLATION

TOOLS AND INSTALLATION TOOLS AND INSTALLATION Safe, leak-free operation of any high-pressure system is dependent on correctly prepared and installed connections. This section outlines proper instructions for the machining and

More information

Durapipe ABS Jointing Guide

Durapipe ABS Jointing Guide Durapipe ABS Jointing Guide Solvent cement welding offers a simple and quick means of constructing high integrity, leak-free joints. The solvent cement operates by chemically softening the joint surfaces.

More information

SEALING METHODS AND HARDWARE FOR EQUIPMENT AND PROCESSES APRIL 11-12, 2018

SEALING METHODS AND HARDWARE FOR EQUIPMENT AND PROCESSES APRIL 11-12, 2018 SEALING METHODS AND HARDWARE FOR EQUIPMENT AND PROCESSES APRIL 11-12, 2018 SEALING METHODS AND HARDWARE FOR EQUIPMENT AND PROCESSES INTRODUCTION to APM HEXSEAL PURPOSE To review various ways to seal equipment

More information

Indumax CLS50/CLS50D. Technical Information

Indumax CLS50/CLS50D. Technical Information Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D

More information

Technical data for Brother TZe Tapes

Technical data for Brother TZe Tapes Technical data for Brother TZe Tapes Why do Brother P-Touch laminated labels last longer? Unlike ordinary labels, our unique laminated tape technology ensures that a layer of superclear polyethylene laminate

More information

Figure 11 Flange Adapter and Back-Up Ring

Figure 11 Flange Adapter and Back-Up Ring Flange Adapters Standard back-up rings are Standard back-up rings are convoluted ductile iron with AWWA C207 150 lb drilling. One edge of the back-up ring bore must be radiused or chamfered. This edge

More information

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable Features 72.01 72.11 Level control relays for conductive liquids 72.01 - Adjustable sensitivity 72.11 - Fixed sensitivity Emptying or filling functions LED indicator Reinforced insulation (6 kv - 1.2/50

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Magnetic Length Measuring System

Magnetic Length Measuring System SERIE EMIX1 Magnetic Length Measuring System With index pulse Resolution 0.01 mm (at 4 edge triggering) Repeating accuracy +/- 1 increment Small sensor with integrated translator Speed proportional output

More information

CEELOK FAS-T* High-Speed Circular Connector System

CEELOK FAS-T* High-Speed Circular Connector System CEELOK FAS-T* High-Speed Circular Connector System Application Specification 114-32025 02 APR 12 NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are

More information

INSTALLATION MANUAL FOR STAINLESS STEEL, GROOVE-END, FLEXIBLE COUPLINGS

INSTALLATION MANUAL FOR STAINLESS STEEL, GROOVE-END, FLEXIBLE COUPLINGS PIEDMONT PACIFIC CORPORATION INSTALLATION MANUAL FOR STAINLESS STEEL, GROOVE-END, FLEXIBLE COUPLINGS 4703 Tidewater Ave., Suite G Oakland. CA, 94601, USA Ph: +1 510 434 0990 / Fax: +1 510 436 0990 www.piedmontpacific.com

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable 72 Series - Monitoring relays 16 A Features 72.01 72.11 Level control relays for conductive liquids 72.01 - Adjustable sensitivity 72.11 - Fixed sensitivity Emptying or filling functions LED indicator

More information

Preparatory work. Core activity

Preparatory work. Core activity 7714100 Installing crash bars + 77 14 500 Equipment trim-level variant: OA Crash bars NOTICE Engine protection bars cannot be installed in combination with left and right protectors for engine. Preparatory

More information

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable Features Level control relays for conductive liquids 72.01 - Adjustable sensitivity 72.11 - Fixed sensitivity Emptying or filling functions LED indicator Reinforced insulation (6 kv - 1.2/50 µs) between:

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Understanding pipe threads: types and designations

Understanding pipe threads: types and designations WHITE PAPER 8008 Understanding pipe threads: types and designations By Mark Schmidt Applications Engineer CPC (Colder Products Company) Different types of screw threads have evolved for fastening and hydraulic

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS 3 YEARS WARRANTY PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS MAIN FEATURES 2-wire K-band Pulse Burst Radar 25 GHz frequency

More information

XT Technical Documentation. The magnetostrictive level sensor. Edition: Version: 1 Article no.:

XT Technical Documentation. The magnetostrictive level sensor. Edition: Version: 1 Article no.: Technical Documentation The magnetostrictive level sensor Edition: 11-2010 Version: 1 Article no.: 233571 Gems Sensors & Controls One Cowles Rd Plainville CT Telephone 800-378-1600 Page 2/19 Table of contents

More information

Monitoring relays and float switch 72

Monitoring relays and float switch 72 and float switch 72 SЕRIS Industrial washing machines Swimming pools Control and management of water Bottling plant Milk processing plant Control panels for pumps FINDR reserves the right to alter characteristics

More information

Assembly instructions

Assembly instructions Assembly instructions Important notes on VOSS assembly instructions In order to ensure maximum performance and functional reliability of VOSS products, the respective assembly instructions, operating conditions

More information

LVDT. Inductive Position Transducer. SLX-series. designed for pharmaceutical, medical and food industry. content: Key-Features:

LVDT. Inductive Position Transducer. SLX-series. designed for pharmaceutical, medical and food industry. content: Key-Features: LVDT Inductive Position Transducer SL-series content: Cable Break Detection...6...7 designed for pharmaceutical, medical and food industry Key-Features: - stainless steel housing - high protection class

More information

K-BAND RADAR FOR LIQUIDS

K-BAND RADAR FOR LIQUIDS K-BAND RADAR FOR LIQUIDS LEVEL TRANSMITTERS PULSE BURST RADAR LEVEL TRANSMITTERS O U R P R O F E S S I O N PiloTREK NON-CONTACT MICROWAVE LEVEL TRANSMITTERS FOR LIQUIDS MAIN FEATURES 2-wire K-band Pulse

More information

RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE IP68 RCP RESIN BUSBAR TRUNKING New resin busbar RCP ranging from 6 A to A and IP68 degree of protection,

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor

More information

Cabtite Cable entry system. Cable entries and Cabtite

Cabtite Cable entry system. Cable entries and Cabtite Cabtite Cable entry system Do you really need a plug-in connector on the outside of your switchgear cabinet? Or do you simply just want to make the right connections? Now you can save space, time and money

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

HIGH VOLUME LOW PRESSURE COMPRESSED AIR SPRAY GUNS

HIGH VOLUME LOW PRESSURE COMPRESSED AIR SPRAY GUNS INSTRUCTION MANUAL (For Professional Use Only) HIGH VOLUME LOW PRESSURE COMPRESSED AIR SPRAY GUNS DO NOT USE SPRAY GUNS BEFORE READING THIS MANUAL 8000 8200 8400 This manual contains important warnings

More information

TB404 Conductivity sensors. Perfect for use in standard to highly corrosive solutions

TB404 Conductivity sensors. Perfect for use in standard to highly corrosive solutions Data sheet TB404 Conductivity sensors Toroidal Perfect for use in standard to highly corrosive solutions Greatly reduces coating and other fouling problems Inductive measurement technique yields a solution

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance Thermometers Model Series TR7X0, Sheathed Design Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS General Information Assmann polyethylene storage tanks are manufactured to give you the toughest, most reliable

More information

ES Series Features Detecting distance twice that of conventional

ES Series Features Detecting distance twice that of conventional Long-distance Separate-amplifier Series Features Detecting distance twice that of conventional sensors Detecting distance easily adjustable Wide range of sensor head types available Built-in alarm output

More information

Magnetic, Incremental - Length Measuring System. Only functional with an ELGO MB R magnetic tape!

Magnetic, Incremental - Length Measuring System. Only functional with an ELGO MB R magnetic tape! GMIX1A Series Magnetic, Incremental - Length Measuring System 5 different adjustable resolutions between 0.1 and 0.01 mm s (at 4 edge triggering) repeat accuracy +/- 1 increment 5V-TTL or 10...30 V Push/Pull

More information

TRX SERIES LIGHTBARS

TRX SERIES LIGHTBARS 3/14/2016 TRX SERIES LIGHTBARS TRX-20 TRX-35 TRX-50 TRX-25 TRX-30 TRX-40 TRX-45 TRX-60 Product Manual TOMAR OFF-ROAD, 2100 W OBISPO AVE, GILBERT, AZ 85233 800-338-2133 www.tomaroff-road.com Wiring Main

More information

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe Guided microwave level transmitters GENERAL DESCRITION The Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids, pulps and solids. level

More information

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.* Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT

More information

Tools required for maintenance and fitting/removal.

Tools required for maintenance and fitting/removal. FITTING, REMOVAL AND MAINTENANCE OF YOUR H5 BALL BEARING AUTOPROP. The Autoprop is supplied assembled, tested, and ready to fit to your yacht. Observing the following notes will ensure correct fitting

More information

Overview Better by Design

Overview Better by Design 4Conduit & Fittings Ocal Corrosion-Resistant Conduit Systems Overview Better by Design Ocal PVC-coated conduit and fittings represent a complete corrosionprotection package for your entire conduit system.

More information

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products Presented to valued clients attending the Technology Summit hosted by: Kendall Group/ J.O.Galloup +GF+ Offering Level Measurement Continuous

More information

Alongside manufacturing excellence are the standards we set and maintain to ensure our delivery responsiveness is second to none.

Alongside manufacturing excellence are the standards we set and maintain to ensure our delivery responsiveness is second to none. Product Catalogue NCS International About Us With over 20 years of industry leading experience, Techno Plas is a fully Australian owned and operated company with our head office in St Marys, South Australia.

More information

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4 I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)

More information

IP68 RCP RESIN BUSBAR TRUNKING FOR POWER DISTRIBUTION POWERED BY SPECIALISTS

IP68 RCP RESIN BUSBAR TRUNKING FOR POWER DISTRIBUTION POWERED BY SPECIALISTS IP68 RCP RESIN BUSBAR TRUNKING FOR POWER DISTRIBUTION POWERED BY SPECIALISTS IP68 RCP RCP RESIN busbar trunking resin busbar is the latest addition to the Zucchini range. With an ingress protection rating

More information

STEWARD ECO T01-B INSTALLATION INSTRUCTIONS L URINAL (REAR INLET) K-4986T-ER( ) , 2010 Copyright Kohler China Ltd.

STEWARD ECO T01-B INSTALLATION INSTRUCTIONS L URINAL (REAR INLET) K-4986T-ER( ) , 2010 Copyright Kohler China Ltd. STEWARD ECO INSTALLATION INSTRUCTIONS 0.5 0.5L URINAL (REAR INLET) K-4986T-ER BEFORE YOU BEGIN Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE (60A type only) RELAYS A PC board type 80A Connector type 60A Screw terminal type A TM type 300A Connector type RoHS Directive compatibility

More information

Light Clamps. Light load range. Technical data/properties...page 29. Right angle tube connector...page 34. Axially parallel tube connector...

Light Clamps. Light load range. Technical data/properties...page 29. Right angle tube connector...page 34. Axially parallel tube connector... Light load range Technical data/properties...page 29 Right angle tube connector...page 34 xially parallel tube connector...page 38 Hinge tube connector...page 41 ccessories...page 48 RK LightClamps Light

More information

Powersafe Termination Guide

Powersafe Termination Guide Powersafe Termination Guide Contents Index 1. Introduction 2. Overview 3. Termination Methods 3.1 Set screw termination 3.2. Recommended Assembly Procedure for Panel Mounted Connectors 3.3. Crimp Termination

More information

LF (Large Flange) Fittings - Adapters. (505)

LF (Large Flange) Fittings - Adapters.   (505) LF (Large ) Fittings - dapters www.idealvac.com (505)72-007 Vacuum Fittings - dapters - olt Sets LF (Large ) ISO NW LF Specifications Max. Positive Pressure over pressure centering ring 0 psig Torque Rating

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

400 SERIES GRINDER PUMPS 41502, 42202,43302, AND MODELS

400 SERIES GRINDER PUMPS 41502, 42202,43302, AND MODELS Section: MOYNO 500 PUMPS Page: 1 of 6 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 400 SERIES GRINDER PUMPS 41502, 42202,43302, AND 44402 MODELS DESIGN FEATURES Housing: Cast iron Pump Rotor: Chrome

More information

Bepop PET Label White/Silver Technical Data Rev. 5

Bepop PET Label White/Silver Technical Data Rev. 5 Bepop / Technical Rev. 5 Product name Product overview Subject machine types SL-S53N SL-S54N This is a film for creating labels that uses (polyethylene terephthalate) as the material. It is suitable for

More information

CINTRALUX ALU BARREL VAULT EP 10/10

CINTRALUX ALU BARREL VAULT EP 10/10 CINTRALUX ALU BARREL VAULT EP 10/10 Installation instructions EN 14963 Artn 43984 E_MH_Cintralux EP 10/10 mm AG.PLASTICS QUALITY 1 Installation instructions Cintralux aluminium barrel vault: Cintralux

More information

Better by Design. PVC Coated Conduit System. Technical Services Tel: Canada Tel: Fax:

Better by Design.  PVC Coated Conduit System. Technical Services Tel: Canada Tel: Fax: PVC Coated Conduit System Overview Ocal Blue PVC coated conduit and fittings represent a complete corrosion protection package for your entire conduit system. This extensive product line includes the largest

More information

A PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF LIQUIDS K-PATENTS PROCESS REFRACTOMETER PR-23-GP SB:PR-23-GP/0

A PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF LIQUIDS K-PATENTS PROCESS REFRACTOMETER PR-23-GP SB:PR-23-GP/0 A PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF LIQUIDS K-PATENTS PROCESS REFRACTOMETER PR-23-GP SB:PR-23-GP/0 TYPICAL APPLICATIONS CHEMICALS Acetic acid, Acrylate, Amine oxide, Amino acid, Ammonium

More information

MODULAR PHENOLIC CASEWORK

MODULAR PHENOLIC CASEWORK MODULAR PHENOLIC CASEWORK 1.00 General 1.01 General Conditions A) The General Conditions and Supplementary General Conditions apply to all work in this division. B) Warranty: BMT/Nelson Phenolic Casework

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts Emergency pull-wire switches ZS 71... NA Technical data Contact variations * 63 mm for version 200 N pre-tensioning force To EN 418/IEC 60947-5-5 Metal enclosure 2 contacts Integrated emergency-stop button

More information

Guided Wave Radar Bulk Solids Level Transmitter

Guided Wave Radar Bulk Solids Level Transmitter www.ktekcorp.com Guided Wave Radar Bulk Solids Level Transmitter FEATURES Radar Signal Travels Along the Waveguide Eliminates False Echoes and Minimizes Signal Loss No Moving Parts 2 Wire Loop Powered

More information

Float switch For industrial applications, plastic version Model RLS-2000

Float switch For industrial applications, plastic version Model RLS-2000 Level measurement Float switch For industrial applications, plastic version Model RLS-2000 WIKA data sheet LM 50.04 Applications Level measurement of liquids in machine building Control and monitoring

More information

2 MIL BLUE URETHANE COATED INTERIOR, 40 MIL PVC COATED EXTERIOR

2 MIL BLUE URETHANE COATED INTERIOR, 40 MIL PVC COATED EXTERIOR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 CPL3 3" Gray PVC CTD Coupling Thomas & Betts Catalog Number Manufacturer Description Weight per unit Product Category

More information

Components made of special materials. Floor Elements for Profile St Profile KH. Fastening Elements for Profile KH

Components made of special materials. Floor Elements for Profile St Profile KH. Fastening Elements for Profile KH Profile Fastening Elements for Profile Floor Elements for Profile Profile KH Fastening Elements for Profile KH Components made of special materials Products in this section Profile 8 x eel profile that

More information

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY EV RELAYS (AEV) 80A A 0A FEATURES. High-, high-current control possible 0 high- switching cutoff has been achieved thanks to a sealed construction

More information

E.C. HOPKINS LTD PGO4 PEANUT GRINDER OPERATORS MANUAL AND PARTS LIST

E.C. HOPKINS LTD PGO4 PEANUT GRINDER OPERATORS MANUAL AND PARTS LIST E.C. HOPKINS LTD PGO4 PEANUT GRINDER OPERATORS MANUAL AND PARTS LIST E.C. HOPKINS LTD UNIT 1, 82 KETTLES WOOD DRIVE, WOODGATE BUSINESS PARK, WOODGATE VALLEY, BIRMINGHAM B32 3DB TEL NO. +44 (0)121 506 6095

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher Model # 100 Standard Model #100-U Heavy Duty CAUTION: Read and Understand

More information

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm Electrical contacts stainless steel thermometers T11 - T12 - T13 Ø - Ø 1 - Ø 160 mm Derived from the TX thermometers of nominal diameter, 1 and 160, of which they possess all the characteristics, the T11,

More information

Section Steel Laboratory Casework Specifications 6/1/14 STEEL LABORATORY CASEWORK

Section Steel Laboratory Casework Specifications 6/1/14 STEEL LABORATORY CASEWORK PART 1 GENERAL 1.00 SUMMARY STEEL LABORATORY CASEWORK A. Section Includes: Steel Laboratory Casework B. Section Includes: 1. Painted Steel Casework. 2. Painted Steel Table Frames. C. Related Sections:

More information

Safety Mats Product Range

Safety Mats Product Range Proven Safety Pressure Sensitive Mats Pressure sensitive mats are protective devices used for protecting areas. They comprise sensor, control device and output signal switching device(s). 1.1.1 sensor

More information

CSi Solid Phenolic Casework Standard Specifications

CSi Solid Phenolic Casework Standard Specifications CANADIAN SCIENTIFIC inc 7777 Eastview Rd., Guelph, ON N1H 6J1 info@canadianscientific.ca 226.780.4793 1.00 General CSi Solid Phenolic Casework Standard Specifications 1.01 General Conditions A. The General

More information

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back HSF 250 Patriot Heavy Duty Line Stop Fitting - 4, 6, 8 inch Nominal Sizes Line Stop Fitting Installation Instructions Push and Pin Completion Plug Installation Instructions IMPORTANT: Read installation

More information

A PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF LIQUIDS K-PATENTS PROCESS REFRACTOMETER PR-23-GP SB:PR-23-GP/0

A PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF LIQUIDS K-PATENTS PROCESS REFRACTOMETER PR-23-GP SB:PR-23-GP/0 A PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF LIQUIDS K-PATENTS PROCESS REFRACTOMETER PR-23-GP SB:PR-23-GP/0 TYPICAL APPLICATIONS CHEMICALS Acetic acid, Acrylate, Amine oxide, Amino acid, Ammonium

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS ROTARY VANE POSITIVE DISPLACEMENT DRY-AIR PUMPS VAPOR-OIL PUMPS MADE IN AMERICA SINCE 1939 CONGRATULATIONS! You have purchased one of the most dependable and thoroughly proven Rotary

More information

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable Siemens G 008 SIMTIC PXI inductive proximity switches Introduction Inductive proximity switches rugged, accurate and reliable PXI series The inductive proximity switches are organized in different product

More information

DETAIL SPECIFICATION SHEET FITTINGS - INSTALLATION OF FLARED TUBE, STRAIGHT, THREADED CONNECTORS, DESIGN STANDARD FOR

DETAIL SPECIFICATION SHEET FITTINGS - INSTALLATION OF FLARED TUBE, STRAIGHT, THREADED CONNECTORS, DESIGN STANDARD FOR INCH-POUND MS21344A 4 October 2016 SUPERSEDING MS21344 17 August 1971 DETAIL SPECIFICATION SHEET FITTINGS - INSTALLATION OF FLARED TUBE, STRAIGHT, THREADED CONNECTORS, DESIGN STANDARD FOR This specification

More information

Fitting Instructions

Fitting Instructions Fitting Instructions = Actions. Red = Notes you must read before continuing. Grey = Only applies to canopies over 4m widths. Overview 1. Tools you will need. 2. What you will need to provide. 3. Description

More information

Measuring and Controlling Unit Multronic OC

Measuring and Controlling Unit Multronic OC Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously

More information