1 Enabling Enabling Legendary Legendary Discovery Discovery LEGENDplex Mul -Analyte Flow Flow Assay Kit Kit Cat. No , Human Macrophage/Microglia Panel (13-plex) with Filter Plate Cat. No , Human Macrophage/Microglia Panel (13-plex) with V-bottom Plate Cat. No , Human M1 Macrophage Panel (8-plex) with Filter Plate Cat. No , Human M1 Macrophage Panel (8-plex) with V-bottom Plate Cat. No , Human M2 Macrophage Panel (6-plex) with Filter Plate Cat. No , Human M2 Macrophage Panel (6-plex) with V-bottom Plate Cat. No , Human M1/M2 Macrophage Panel (10-plex) with Filter Plate Cat. No , Human M1/M2 Macrophage Panel (10-plex) with V-bottom Plate For Accurate Quantification of Multiple Human Th (T helper Cell) Cytokines from Cell Culture Supernatant, Serum, Plasma and Other Biological s Please read the entire manual before running the assay. Please read the entire manual before running the assay BioLegend.com BioLegend.com

2 It is highly recommended that this manual be read in its entirety before using this product. Do not use this kit beyond the expiration date. For Research Purposes Only. Not for use in diagnostic or therapeutic procedures. Purchase does not include or carry the right to resell or transfer this product either as a stand-alone product or as a component of another product. Any use of this product other than the permitted use without the express written authorization of BioLegend is strictly prohibited.

3 Table of Contents Page Chapter 1: KIT DESCRIPTION... 3 Introduction... 3 Principle of the Assay Beads Usage Storage Information Materials Supplied Materials to be Provided by the End-User Precautions Chapter 2: ASSAY PREPARATION Collection and Handling Reagent Preparation Standard Preparation Dilution Chapter 3: ASSAY PROCEDURE Performing the Assay Using a Filter Plate Performing the Assay Using a V- bottom Plate Chapter 4: FLOW CYTOMETER SETUP Chapter 5: DATA ACQUISITION AND ANALYSIS Data Acquisition Data Analysis Chapter 6: ASSAY CHARACTERIZATION Representative Standard Curve Assay Sensitivity Cross-Reactivity Accuracy Linearity of Dilution biolegend.com 1

4 Intra-Assay Precision Inter-Assay Precision Biological s TROUBLESHOOTING PLATE MAP Tel:

5 Chapter 1: KIT DESCRIPTION Introduction Macrophages are produced by differentiation of monocytes in response to an infection or tissue damage. Their primary function is to recognize, engulf, and destroy target cells including pathogens, dying or dead cells and cellular debris. Like dendritic cells, macrophages are also professional antigen presenting cells that play a crucial role in initiating an immune response. Macrophages secrete an array of cytokines which aid in host defense, tissue repair, and immunoregulation. Macrophages can be divided into multiple subtypes based on different functions. Inflammation-encouraging M1 macrophages produce proinflammatory cytokines, such as IL-12p70, TNF-α, IL-6, IL-1β, IL-12p40, IL-23, IFN-γ, and IP-10. Anti-inflammatory and tissue-repairing M2 macophages decrease immune reactions and promote tissue repair by releasing a different set of factors, such as IL-4, IL-10, IL-6, Arginase, TARC, and IL-1RA. Due to their important roles in immune responses, macrophages are critically involved in a variety of human inflammatory disorders, such as sepsis-related multiple organ dysfunction/failure, microbial infection, acute injuries, neurodegenerative disorders, cancer, cardiovascular, and autoimmune diseases. Measuring the mediators of proinflammation and anti-inflammation produced by macrophages may help not only in understanding the fundamental functions of macrophages, but also in finding the mechanisms of various pathological processes. The LEGENDplex TM Human Macrophage/Microglia Panel (13-plex) is a beadbased multiplex assay panel, using fluorescence-encoded beads suitable for use on various flow cytometers. It allows for simultaneous quantification of 13 key targets involved in monocyte differentiation and macrophage functions including Arginase, IFN-γ, IL-10, IL-12(p40), IL-12(p70), IL-1RA, IL-1β, IL-23, IL-4, IL-6, IP-10, TARC, and TNF-α. This assay panel provides higher detection sensitivity and broader dynamic range than traditional ELISA methods. The panel has been validated for use on cell culture supernatant, serum, and plasma samples. The LEGENDplex TM Human Macrophage/Microglia Panel is designed to allow flexible customization within the panel. It can also be divided into subpanels such as: LEGENDplex TM Human M1 Macrophage Panel (8-plex) LEGENDplex TM Human M2 Macrophage Panel (6-plex) LEGENDplex TM Human M1/M2 Macrophage Panel (10-plex) Please visit for more information on how to mix and match within the panel. biolegend.com 3

6 Principle of the Assay BioLegend s LEGENDplex TM assays are bead-based immunoassays using the same basic principle as sandwich immunoassays. Beads are differentiated by size and internal fluorescence intensities. Each bead set is conjugated with a specific antibody on its surface and serves as the capture beads for that particular analyte. When a selected panel of capture beads is mixed and incubated with a sample containing target analytes specific to the capture antibodies, each analyte will bind to its specific capture beads. After washing, a biotinylated detection antibody cocktail is added, and each detection antibody in the cocktail will bind to its specific analyte bound on the capture beads, thus forming capture bead-analyte-detection antibody sandwiches. Streptavidin-phycoerythrin (SA-PE) is subsequently added, which will bind to the biotinylated detection antibodies, providing fluorescent signal intensities in proportion to the amount of bound analytes. Since the beads are differentiated by size and internal fluorescence intensity on a flow cytometer, analyte-specific populations can be segregated and PE fluorescent signal quantified. The concentration of a particular analyte is determined using a standard curve generated in the same assay. Beads Usage The Human Macrophage/Microglia Panel uses two sets of beads. Each set has a unique size that can be identified based on their forward scatter (FSC) and side scatter (SSC) profiles (Beads A and Beads B, Figure 1). Each bead set can be further resolved based on their internal fluorescence intensities. The internal dye can be detected using FL3, FL4, or APC channel, depending on the type of flow cytometer used. The smaller Beads A consists of 6 bead populations and the larger Beads B consists of 7 bead populations (Figure 2-3). Using a total of 13 bead populations distinguished by size and internal fluorescent dye, the Human Macrophage/Microglia Panel allows simultaneous detection of 13 cytokines in a single sample. Each analyte is associated with a particular bead set as indicated (Figures 2-3 and Table 1). Figure 1. Beads Differentiated by Size Beads A = smaller beads Beads B = larger beads 4 Tel:

7 Figure 2. Beads A Classification by FL4 Figure 3. Beads B Classification by FL4 For Beads usage in the panel, please refer to Table 1 below: Table 1. Panel Targets and Bead ID Target Bead ID Macrophage/ Microglia Panel Cat No or M1 Panel Cat. No or M2 Panel Cat. No or biolegend.com M1/M2 Panel Cat. No or IL-12p70 A4 TNF-α A5 IL-6 A6 IL-4 A7 IL-10 A8 IL-1β A10 Arginase B2 TARC B3 IL-1RA B4 IL-12p40 B5 IL-23 B6 IFN-γ B7 IP-10 B9 Top Standard Concentrations The top standard concentration of each target may vary and may subject to change from lot to lot. Please refer to the lot-specific Certificate of Analysis for this information *Bead ID is used to associate a bead population to a particular analyte in the LEGENDplex TM Data Analysis Software. The association of analyte and bead ID will be defined during the gating step of the data analysis. 5

8 When entering analyte and bead ID infomation during the gating step, always enter in the sequential order of the bead ID (e.g, A4, A5, A6...B2, B3, B4...). Please refer to the LEGENDplex TM Data Analysis Software User Guide and Online Help for details ( Storage Information Recommended storage for all original kit components is between 2 C and 8 C. DO NOT FREEZE Pre-mixed Beads, Detection Antibodies or SA-PE. 6 Once the standards have been reconstituted, immediately transfer contents into polypropylene vials. DO NOT STORE RECONSTITUTED STAN- DARDS IN GLASS VIALS. Upon reconstitution, leftover standard and Matrix B1 should be stored at -70 C for use within one month. Avoid multiple (>2) freeze-thaw cycles. Discard any leftover diluted standards. Materials Supplied The LEGENDplex TM kit contains reagents for 100 tests, listed in the table below. When assayed in duplicate, this is enough for an 8-point standard curve and 40 samples. Kit Components Quantity Volume Part # Setup Beads 1: FITC Beads 1 vial 1 ml Setup Beads 2: PE Beads 1 vial 1 ml Setup Beads 3: Raw Beads 1 vial 2 ml Capture Beads* (see tables below for more information) Human Macrophage/Microglia Panel Detection Antibodies Human Macrophage/Microglia Panel Standard Cocktail, Lyophilized Tel: varies varies varies* 1 bottle 3.5 ml varies* 1 vial lyophilized varies* LEGENDplex TM SA-PE 1 bottle 3.5 ml LEGENDplex TM Matrix B1, Lyophilized 1 vial lyophilized LEGENDplex TM Assay Buffer 1 bottle 25 ml LEGENDplex TM Wash Buffer, 20X 1 bottle 25 ml Filter Plate**or V-bottom Plate*** 1 plate 76187** or 76883*** Plate Sealers 4 sheets Data Analysis Software Dongle

9 Kit Components Quantity Volume Part # Human Macrophage/Microglia Panel Manual biolegend.com * For full panel, premixed beads are provided ready-to-use. For subpanels, individual beads are provided at 13X concentration. For Standard and Detection Antibodies, full panels use part numbers and subpanels use catalog numbers (See tables below for details). ** For kit with filter plate. *** For kit with V-bottom plate. Only one plate is provided for each kit. For Macrophage/Microglia Panel (Full Panel): Kit Components Quantity Volume Part # Human Macrophage/Microglia Panel Premixed Beads 1 bottle 3.5 ml Human Macrophage/Microglia Panel Detection Antibodies Human Macrophage/Microglia Panel Standard Cocktail, Lyophilized For Macrophage/Microglia Subpanels: 1 bottle 3.5 ml vial Kit Components Quantity Volume Cat.# LEGENDplex Human IL-12p70 Capture Bead A4, 13X 1 vial 270 µl LEGENDplex Human TNF-α Capture Bead A5, 13X 1 vial 270 µl LEGENDplex Human IL-6 Capture Bead A6, 13X 1 vial 270 µl LEGENDplex Human IL-4 Capture Bead A7, 13X 1 vial 270 µl LEGENDplex Human IL-10 Capture Bead A8, 13X 1 vial 270 µl LEGENDplex Human IL-1β Capture Bead A10, 13X 1 vial 270 µl LEGENDplex Human Arginase Capture Bead B2, 13X 1 vial 270 µl LEGENDplex Human TARC Capture Bead B3, 13X 1 vial 270 µl LEGENDplex Human IL-1RA Capture Bead B4, 13X 1 vial 270 µl LEGENDplex Human IL-12p40 Capture Bead B5, 13X 1 vial 270 µl LEGENDplex Human IL-23 Capture Bead B6, 13X 1 vial 270 µl LEGENDplex Human IFN-γ Capture Bead B7, 13X 1 vial 270 µl LEGENDplex Human IP-10 Capture Bead B9, 13X 1 vial 270 µl LEGENDplex Human Macrophage/Microglia Panel Detection Antibodies LEGENDplex Human Macrophage/Microglia Panel Standard 1 bottle 3.5 ml vial lyophilized lyophilized

10 Please refer to Beads ID and Panel-Specific Target Selection table (Table 1, page 5), to see which capture beads are included in each panel Materials to be Provided by the End-User A flow cytometer equipped with two lasers (e.g., a 488 nm blue laser or 532 nm green laser and a nm red laser) capable of distinguishing 575 nm and 660 nm or a flow cytometer equipped with one laser (e.g., 488 nm blue laser) capable of distinguishing 575 nm and 670 nm. Partial list of compatible flow cytometers: Flow Cytometer BD FACSCalibur TM (single laser) BD FACSCalibur TM (dual laser) Reporter Channel Channel Emission Classification Channel Absorbent pads or paper towels 8 Tel: Channel Emission Compensation needed? FL2 575 nm FL3 670 nm Yes FL2 575 nm FL4 660 nm No* BD FACSArray TM Yellow 575 nm Red 660 nm No* BD Accuri TM C6 FL2 585 nm FL4 675 nm No* BD FACSCanto TM BD FACSCanto TM II BD TM LSR, LSR II BD LSRFortessa TM PE 575 nm APC 660 nm No* PE nm APC 660 nm No* BD FACSAria TM PE 575 nm APC 660 nm No* Beckman Coulter- CytoFLEX PE 585 nm APC 660 nm No* *Compensation is not required for the specified flow cytometers when set up properly. For setting up various flow cytometers, please visit: legendplex and click on the Instrument Setup tab. Multichannel pipettes capable of dispensing 5 μl to 200 μl Reagent reservoirs for multichannel pipette Polypropylene microfuge tubes (1.5 ml) Laboratory vortex mixer Sonicator bath (e.g., Branson Ultrasonic Cleaner model #B200, or equivalent) Aluminum foil

11 Plate shaker (e.g., Lab-Line Instruments model #4625, or equivalent) Tabletop centrifuges (e.g., Eppendorf centrifuge 5415 C, or equivalent) If the assay is performed in a filter plate (recommended); A vacuum filtration unit (Millipore MultiScreen HTS Vacuum Manifold, cat # MSVMHTS00 or equivalent). Instructions on how to use the vacuum manifold can be found at the supplier s website. A vacuum source (mini vacuum pump or line vacuum, e.g., Millipore Vacuum Pump, catalog # WP , or equivalent) If needed, additional Filter plate can be ordered from BioLegend (Cat# or ) If the assay is performed in a V-bottom plate (optional); Centrifuge with a swinging bucket adaptor for microtiter plates (e.g., Beckman Coulter Allegra TM 6R Centrifuge with MICROPLUS CARRIER adaptor for GH3.8 and JS4.3 Rotors). If needed, additional V-bottom plate can be ordered from BioLegend (Cat# ) Precautions All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Center for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents. Sodium azide has been added to some reagents as a preservative. Although the concentrations are low, sodium azide may react with lead and copper plumbing to form highly explosive metal azides. On disposal, flush with a large volume of water to prevent azide build-up. Matrix B1 for LEGENDplex TM kits contains components of human origin and should be handled as potentially hazardous. The raw material has been screened for infectious diseases and is negative for HIV, HBV and HCV using FDA-approved test methods. Do not mix or substitute reagents from different kits or lots. Reagents from different manufacturers should not be used with this kit. Do not use this kit beyond its expiration date. SA-PE and beads are light-sensitive. Minimize light exposure. biolegend.com 9

12 Chapter 2: ASSAY PREPARATION Collection and Handling Preparation of Serum s: Allow the blood to clot for at least 30 minutes and centrifuge for 20 minutes at 1,000 x g. Remove serum and assay immediately or aliquot and store samples at -20 C. Avoid multiple (>2) freeze/thaw cycles. When using frozen samples, it is recommended that samples are thawed completely, mixed and centrifuged to remove particulates prior to use. Preparation of Plasma s: Plasma collection using EDTA as an anti-coagulant is recommended. Centrifuge for 20 minutes at 1,000 x g within 30 minutes of blood collection. Remove plasma and assay immediately, or aliquot and store samples at -20 C. Avoid multiple (>2) freeze/thaw cycles. When using frozen samples, it is recommended that samples are thawed completely, mixed well and centrifuged to remove particulates. 10 Preparation of Tissue Culture Supernatant: Centrifuge the sample to remove debris and assay immediately. If not possible, aliquot and store samples at -20 C. Avoid multiple (>2) freeze/thaw cycles. Reagent Preparation Preparation of Antibody-Immobilized Beads If pre-mixed beads are provided in the kit: Sonicate pre-mixed Beads bottle for 1 minute in a sonicator bath and then vortex for 30 seconds prior to use. If no sonicator bath is available, increase the vortexing time to 1 minute to completely resuspend the beads. If individual beads (13X) are provided in the kit: The individual beads (13X) should be mixed with each other and diluted to 1X final concentration with Assay Buffer prior to use. To mix the beads, follow the steps below (a 5-plex subpanel is used as an example): Tel:

13 1. Sonicate the beads vials for 1 minute in a sonicator bath and then vortex for 30 seconds to completely resuspend the beads. 2. Calculate the amount of mixed and diluted beads needed for the assay. Prepare extra to compensate for pipetting loss. Each reaction needs 25 µl of mixed and diluted beads. For 50 reactions, prepare 1.5 ml of mixed beads. For 96 reactions, prepare 3 ml of mixed beads. 3. To make 1.5 ml of 5-plex 1X diluted beads, transfer 115 µl of each of the 5 individual beads (13X) to a fresh tube (total bead volume = 575 µl) and add 925 µl of Assay Buffer to make the final volume of 1.5 ml. Preparation of Wash Buffer Bring the 20X Wash Buffer to room temperature and mix to bring all salts into solution. Dilute 25 ml of 20X Wash Buffer with 475 ml deionized water. Store unused portions between 2 C and 8 C for up to one month. Preparation of Matrix B1 (for Serum or Plasma s Only) Add 5.0 ml LEGENDplex TM Assay Buffer to the bottle containing lyophilized Matrix B1. Allow at least 15 minutes for complete reconstitution. Vortex to mix well. Leftover reconstituted Matrix B1 should be stored at -70 C for up to one month. Standard Preparation 1. Prior to use, reconstitute the lyophilized Human Macrophage/Microglia Panel Standard Cocktail, with 250 µl Assay Buffer. 2. Mix and allow the vial to sit at room temperature for 10 minutes, and then transfer the standard to an appropriately labeled polypropylene microfuge tube. This will be used as the top standard C7. Note: The top standard concentrations of analytes in this panel was set at various concentrations, but may be subject to change from lot to lot (see lot-specific Certificate of Analysis provided with kit box for details). 3. Label 6 polypropylene microfuge tubes as C6, C5, C4, C3, C2 and C1, respectively. 4. Add 75 µl of Assay Buffer to each of the six tubes. Prepare 1:4 dilution of the top standard by transferring 25 µl of the top standard C7 to the C6 tube and mix well. This will be the C6 standard. 5. In the same manner, perform serial 1:4 dilutions to obtain C5, C4, C3, C2 and C1 standards (see the table below using the top standard at 10,000 biolegend.com 11

14 pg/ml as an example). Assay Buffer will be used as the 0 pg/ml standard (C0). Tube/Standard ID Serial Dilution Assay Buffer to add (µl) Standard to add Final Conc. (pg/ml) C ,000 C6 1: µl of C7 2,500 C5 1: µl of C6 625 C4 1: µl of C C3 1: µl of C C2 1: µl of C3 9.8 C1 1: µl of C2 2.4 C Dilution Serum or plasma samples must be diluted 2-fold with Assay Buffer before being tested (e.g. dilute 50 µl of sample with 50 µl of Assay Buffer). If further sample dilution is desired, dilution should be done with Matrix B1 to ensure accurate measurement. Adding serum or plasma samples without dilution will result in low assay accuracy and possibly, clogging of the filter plate. For cell culture supernatant samples, the levels of analyte can vary greatly from sample to sample. While the samples can be tested without dilutions, a preliminary experiment may be required to determine the appropriate dilution factor. If sample dilution is desired, dilution should be done with corresponding fresh cell culture medium or Assay Buffer to ensure accurate measurement. 12 Tel:

15 Chapter 3: ASSAY PROCEDURE The LEGENDplex TM assay can be performed in a filter plate, or in a V-bottom plate. The in-filter plate assay procedure is recommended due to its good sample to sample consistency, assay robustness and ease of handling. This procedure requires a vacuum filtration unit for washing (see Materials to be Provided by the End-User, page 8). If you have performed bead-based multiplex assays before, your lab may already have the vacuum filtration unit set up. If the in-filter plate assay procedure is not possible or if you prefer, the assay can be performed in a V-bottom plate. Performing the Assay Using a Filter Plate Allow all reagents to warm to room temperature (20-25 C) before use. Set the filter plate on an inverted plate cover at all times during assay setup and incubation steps, so that the bottom of the plate does not touch any surface. Touching a surface may cause leakage. Keep the plate upright during the entire assay procedure, including the washing steps, to avoid losing beads. The plate should be placed in the dark or wrapped with aluminum foil for all incubation steps. Standards and samples should be run in duplicate and arranged on the plate in a vertical configuration convenient for data acquisition and analysis (as shown in attached PLATE MAP, page 33). Be sure to load standards in the first two columns. If an automation device is used for reading, the orientation and reading sequence should be carefully planned. 1. Pre-wet the plate by adding 100 μl of LEGENDplex TM 1X Wash Buffer to each well and let it sit for 1 minute at room temperature. To remove the excess volume, place the plate on the vacuum manifold and apply vacuum. Do not exceed 10 Hg of vacuum. Vacuum until wells are drained (5-10 seconds). Blot excess Wash Buffer from the bottom of the plate by pressing the plate on a stack of clean paper towels. Place the plate on top of the inverted plate cover. For measuring cell culture supernatant samples, load the plate as shown in the table below (in the order from left to right): biolegend.com 13

16 Assay Buffer Matrix B1 Standard * Standard Wells 25 µl µl --- wells 25 µl µl For measuring serum or plasma samples, load the plate as shown in the table below (in the order from left to right): Assay Buffer Matrix B1 Standard * Standard Wells µl 25 µl --- wells 25 µl µl *See Dilution 2. Vortex mixed beads bottle for 30 seconds. Add 25 μl of mixed beads to each well. The volume should be 75 μl in each well after beads addition. (Note: During addition of the beads, shake mixed beads bottle intermittently to avoid bead settling). 3. Seal the plate with a plate sealer. To avoid plate leaking, do not apply positive pressure to the sealer when sealing the plate. Wrap the entire plate, including the inverted plate cover, with aluminum foil. Place the plate on a plate shaker, secure it and shake at approximate 500 rpm for 2 hours at room temperature. 4. Do not invert the plate! Place the plate on the vacuum manifold and apply vacuum as before in Step 1. Add 200 µl of 1X Wash Buffer to each well. Remove Wash Buffer by vacuum filtration. Blot excess Wash Buffer from the bottom of the plate with an absorbent pad or paper towels. Repeat this washing step once more. 5. Add 25 µl of Detection Antibodies to each well. 6. Seal the plate with a fresh plate sealer. Wrap the entire plate, including the inverted plate cover, with aluminum foil. Place the plate on a plate shaker and shake at approximately 500 rpm for 1 hour at room temperature. 7. Do not vacuum! Add 25 µl of SA-PE to each well directly. 8. Seal the plate with a fresh plate sealer. Wrap the entire plate, including the inverted plate cover, with aluminum foil. Place the plate on a plate shaker and shake at approximate 500 rpm for 30 minutes at room temperature. 9. Repeat step 4 above. 10. Add 150 µl of 1X Wash Buffer to each well. Resuspend the beads on a plate shaker for 1 minute. 14 Tel:

17 LEGENDplex Human Macrophage/Microglia Panel 11. Read samples on a flow cytometer, preferably within the same day of the assay (Note: Prolonged sample storage can lead to reduced signal). If the flow cytometer is equipped with an autosampler, read the plate directly using the autosampler. Please be sure to program the autosampler to resuspend beads in the well immediately before taking samples. The probe height may need to be adjusted when using an autosampler. If an autosampler is not available, the samples can be transferred from the filter plate to micro FACS (or FACS) tubes and read manually. Assay Procedure Summary for Filter Plate Add 100 μl 1X Wash Buffer to filter plate wells Vacuum to remove excess buffer Capture beads Analytes For cell culture supernatant samples, Add to the plate: 25 μl Assay Buffer to all wells 25 μl diluted standard to standard wells 25 μl sample to sample wells 25 μl mixed beads to all wells A C B For serum and plasma samples, Add to the plate: 25 μl Matrix B1 to standard wells 25 μl Assay Buffer to sample wells 25 μl diluted standard to standard wells 25 μl sample to sample wells 25 μl mixed beads to all wells Incubate 2 hours, RT, shaking A C B Wash 2 times using vacuum filtration unit Add 25 μl Detection Antibodies Incubate 1 hr, RT, shaking Biotinylated Detection Antibody B C A Without washing, add 25 μl SA-PE Incubate 30 min, RT, shaking Wash 2 times using vacuum filtration unit Add 150 µl of 1x Wash Buffer Read on a flow cytometer biolegend.com 15

18 Performing the Assay Using a V-bottom Plate Allow all reagents to warm to room temperature (20-25 C) before use. Keep the plate upright during the entire assay procedure, including the washing steps, to avoid losing beads. The plate should be placed in the dark or wrapped with aluminum foil for all incubation steps. Standards and samples should be run in duplicate and arranged on the plate in a vertical configuration convenient for data acquisition and analysis (as shown in attached PLATE MAP, page 33). Be sure to load standards in the first two columns. If an automation device is used for reading, the orientation and reading sequence should be carefully planned. 1. For measuring cell culture supernatant samples, load the plate as shown in the table below (in the order from left to right): Assay Buffer Matrix B1 Standard * Standard Wells 25 µl µl --- wells 25 µl µl For measuring serum or plasma samples, load the plate as shown in the table below (in the order from left to right): Assay Buffer Matrix B1 Standard * Standard Wells µl 25 µl --- wells 25 µl µl *See Dilution 2. Vortex mixed beads for 30 seconds. Add 25 μl of mixed beads to each well. The total volume should be 75 μl in each well after beads addition. (Note: During beads addition, shake mixed beads bottle intermittently to avoid bead settling). 3. Seal the plate with a plate sealer. Cover the entire plate with aluminum foil to protect the plate from light. Shake at 800 rpm on a plate shaker for 2 hours at room temperature (Depending on the shaker, the speed may need to be adjusted. The optimal speed is one that is high enough to keep beads in suspension during incubation, but not too high so it causes spill from the wells). 4. Centrifuge the plate at 1050 rpm (~250 g) for 5 minutes, using a swinging bucket rotor (G.H 3.8) with microplate adaptor (Please refer to Materials to be Provided by the End-User, page 8). Do not use excessive centrifugation speed as it may make it harder to resuspend beads in later steps. Make 16 Tel:

19 sure the timer of the centrifuge works properly and standby to make sure the centrifuge reaches preset speed. 5. Immediately after centrifugation, dump the supernatant into a sink by quickly inverting and flicking the plate in one continuous and forceful motion. Do not worry about losing beads even if the pellet is not visible. The beads will stay in the tip of the well nicely. Blot the plate on a stack of clean paper towel and drain the remaining liquid from the well as much as possible. Be careful not to disturb the bead pellet. Alternatively, removal of the supernatant may be completed using a multichannel pipette set at 75 µl. Try to remove as much liquid as possible without removing any beads. Be sure to change pipette tips between each row or column. 6. Wash the plate by dispensing 200 μl of 1X Wash Buffer into each well and incubate for one minute. Repeat step 4 and 5 above. A second wash is optional, but may help reduce background. 7. Add 25 µl of Detection Antibodies to each well. 8. Seal the plate with a new plate sealer. Cover the entire plate with aluminum foil to protect the plate from light. Shake at 800 rpm on a plate shaker for 1 hour at room temperature. 9. Do not wash the plate! Add 25 µl of SA-PE to each well directly. 10. Seal the plate with a new plate sealer. Wrap the entire plate with aluminum foil and shake the plate on a plate shaker at approximate 800 rpm for 30 minutes at room temperature. 11. Repeat step 4 and Wash the plate by dispensing 200 μl of 1X Wash Buffer into each well and incubate for one minute. Repeat step 4 and 5 above. This washing step is optional but it helps to reduce the background. 13. Add 150 µl of 1X Wash Buffer to each well. Resuspend the beads by pipetting. 14. Read samples on a flow cytometer, preferably within the same day of the assay (Note: Prolonged sample storage can lead to reduced signal). If the flow cytometer is equipped with an autosampler, the samples can be read directly. Please be sure to program the autosampler to resuspend beads in the well immediately before taking samples. The probe height may need to be adjusted when using an autosampler. If an autosampler is not available, the samples can be transferred from the plate to micro FACS (or FACS) tubes and read manually. biolegend.com 17

20 Assay Procedure Summary for V-bottom Plate Capture beads Analytes For cell culture supernatant samples, Add to the plate: 25 μl Assay Buffer to all wells 25 μl diluted standard to standard wells 25 μl sample to sample wells 25 μl mixed beads to all wells A B C For serum and plasma samples, Add to the plate: 25 μl Matrix B1 to standard wells 25 μl Assay Buffer to sample wells 25 μl diluted standard to standard wells 25 μl sample to sample wells 25 μl mixed beads to all wells Incubate 2 hours, RT, shaking A B C Spin down beads, remove supernatant Wash 1 time Add 25 μl Detection Antibodies Incubate 1 hr, RT, shaking Biotinylated Detection Antibody A B C Without washing, add 25 μl SA-PE Incubate 30 min, RT, shaking Spin down beads, remove supernatant. Wash 1 time (optional) Add 150 µl of 1x Wash Buffer Read on a flow cytometer 18 Tel:

21 Chapter 4: FLOW CYTOMETER SETUP In order to generate reliable data, the flow cytometer must be set up properly before data acquisition. The setup instructions have been removed from this manual and uploaded onto our website to save paper. To access the setup instructions, please visit: and click on the Instrument Setup tab. Chapter 5: DATA ACQUISITION AND ANALYSIS Data Acquisition 1. Before reading samples, make sure that the flow cytometer is set up properly. 2. Create a new template or open an existing template (for details on how to create a cytometer-specific template, please refer to the Flow Cytometer Setup Guide). 3. Vortex each sample for 5 seconds before analysis. 4. Set the flow rate to low. Set the number of beads to be acquired to about 300 per analyte (e.g., acquire 2,400 beads for a 8-plex assay or 4000 beads for a 13-plex assay). Do not set to acquire total events as samples may contain large amounts of debris. Instead, create a large gate to include both Beads A and Beads B (gate A+B) and set to acquire the number of events in gate A + B. This will exlude majority of the debris. Note: Do not acquire too few or too many beads. Too few beads acquired may result in high CVs and too many beads acquired may result in slow data analysis later. 5. Read samples. When reading samples, set the flow cytometer to setup mode first and wait until bead population is stabilized before recording or switching to acquisition mode. To simplify data analysis using the LEGENDplex TM Data Analysis Software, read samples in the same order as shown on the PLATE MAP attached at the end of the manual. For an in-plate assay, read column by column (A1, B1, C1...A2, B2, C2...). biolegend.com 19

22 When naming data files, try to use simple names with a consecutive numbering for easy data analysis (e.g. for standards, C0.001, C0.002, C1.003, C1.004, C2.005, C2.006, C3.007, C3.008,... C7.015, C7.016; for samples, S1.017, S1.018, S2.019, S2.020, S3.021, S3.022 ) Store all FCS files in the same folder for each assay. If running multiple assays, create a separate folder for each assay. 6. Proceed to data analysis using LEGENDplex TM Data Analysis Software when data acquisition is completed. Data Analysis The FCS file generated on a flow cytometer should be analyzed using BioLegend s LEGENDplex TM Data Analysis Software. The LEGENDplex TM Data Analysis Software can be downloaded for free here: legendplex. For PC users, install the software on a PC running Windows 7 or Windows 8 and use it in conjunction with the Data Analysis Software Dongle included in this kit. The dongle has a license key stored in it and is needed to run the software. To use the dongle, simply plug it in the USB port of the computer on which the data analysis software is installed, prior to launching the software. For Mac users, install on a Mac running Mac OS X version 10.7 (Lion) or later and you will be promoted to request a software license key after the software installation. Follow the LEGENDplex TM Data Analysis Software User Guide and Online Help to use the software ( or press F1 for online help at any step of the data analysis). 20 Tel:

23 Chapter 6: ASSAY CHARACTERIZATION Representative Standard Curve This standard curve was generated using the LEGENDplex TM Human Macrophage/Microglia Panel for demonstration purposes only. A standard curve must be run with each assay Avg MFI IL-12(p70) TNF-α IL-6 IL-4 IL-10 A10.IL-1b Arginase TARC IL-1RA IL-12(p40) IL-23 IFN-γ IP Conc (pg/ml) Assay Sensitivity The assay sensitivity or minimum detectable concentration (MDC) is the theoretical limit of detection calculated using the LEGENDplex TM Data Analysis Software by applying a 5-parameter curve fitting algorithm. Analyte MDC in Serum (pg/ml) MDC in Cell Culture Medium (pg/ml) Human IL-12(p70) Human TNF-α Human IL Human IL Human IL Human IL-1β Human Arginase Human TARC Human IL-1RA biolegend.com 21

24 Human IL-12(p40) Human IL Human IFN-γ Human IP Cross-Reactivity The following human recombinant proteins were tested at 50 ng/ml using the LEGENDplex TM Human Macrophage/Microglia Panel. No or negligible cross-reactivity was found for all the tested analytes. Arginase CXCL12 Eotaxin EPO GM-CSF IFN-γ IGF-II IL-10 IL-12(p40) IL-12(p70) IL-13 IL-17A IL-1RA IL-1α IL-1β IL-2 IL-22 IL-23 IL-33 IL-4 IL-6 IL-8 IP-10 ITAC MCP-1 MCP-4 MIP-1a MIP-1δ MIP-3a MIP-3β MPIF-1 NGAL Paxillin TARC TGF-α TGF-β1 TGF-β2 TGF-β3 TNF-α TNF-β Accuracy (Spike Recovery) For spike recovery in serum, target proteins with known concentrations were spiked into human serum at three different levels within the assay range. The spiked samples were then assayed, and the measured concentrations were compared with the expected values. Analyte % of Rcovery in Serum Analyte % of Rcovery in Serum Human IL-12(p70) 81% Human TARC 86% Human TNF-α 82% Human IL-1RA 98% Human IL-6 88% Human IL-12(p40) 93% Human IL-4 73% Human IL-23 84% Human IL-10 84% Human IFN-γ 109% Human IL-1β 70% Human IP-10 97% Human Arginase 63% 22 Tel:

25 Linearity of Dilution LEGENDplex Human Macrophage/Microglia Panel For testing linearity of dilution, serum samples were first diluted two-fold with Assay Buffer, then serially diluted 1:2, 1:4, 1:8 with Matrix B1 and assayed. The measured concentrations of serially diluted samples were then compared with that of the two-fold diluted samples. Analyte Linearity of Dilution Analyte Linearity of Dilution Human IL-12(p70) 116% Human TARC 101% Human TNF-α 123% Human IL-1RA 122% Human IL-6 113% Human IL-12(p40) 111% Human IL-4 116% Human IL % Human IL % Human IFN-γ 100% Human IL-1β 116% Human IP % Human Arginase 114% Intra-Assay Precision Two samples with different concentrations of target proteins were analyzed in one assay with 16 replicates for each sample. The intra-assay precision was calculated as below. Analyte Human IL-12(p70) Human TNF-α Human IL-6 Human IL-4 Human IL-10 Mean (pg/ml) STDEV %CV % % % % % % % % % % biolegend.com 23

26 Human IL-1β Human Arginase Human TARC Human IL-1RA Human IL-12p40 Human IL-23 Human IFN-γ Human IP % % % % % % % % % % % % % % % % Inter-Assay Precision Two samples with different concentrations of target proteins were analyzed in three independent assays with 3 replicates for each sample. The interassay precision was calculated as below. 24 Analyte Human IL-12(p70) Human TNF-α Human IL-6 Human IL-4 Human IL-10 Mean (pg/ml) Tel: STDEV %CV % % % % % % % % % %

27 Human IL-1β Human Arginase Human TARC Human IL-1RA Human IL-12(p40) Human IL-23 Human IFN-γ Human IP % % % % % % % % % % % % % % % % Biological s Serum and Plasma (s are not paired) Normal human serum samples (n=20) were tested for endogenous levels of the Macrophage/Microglia related cytokines. The concentrations measured are shown below. Analyte Range (pg/ml) % of Detectable Median (pg/ml) Human IL-12(p70) ND % 10.4 Human TNF-α ND % 1.4 Human IL-6 ND % 2.2 Human IL-4 ND % 1.1 Human IL-10 ND % 0.9 Human IL-1β ND % 19.7 biolegend.com 25

28 Human Arginase % Human TARC % Human IL-1RA ND % Human IL-12(p40) ND % 23.2 Human IL-23 ND % 1.4 Human IFN-γ ND % 12.2 Human IP % 48.8 ND = Non-detectable Normal human plasma samples (n=20) were tested for endogenous levels of the Macrophage/Microglia related cytokines. The concentrations measured are shown below. Analyte Range (pg/ml) % of Detectable Median (pg/ml) Human IL-12(p70) ND % 8.8 Human TNF-α ND % 2.9 Human IL-6 ND % 3.6 Human IL % 9.7 Human IL % 2.4 Human IL-1β ND % 29.1 Human Arginase ND % Human TARC % 32.1 Human IL-1RA ND % Human IL-12(p40) % 83.9 Human IL-23 ND % 6.0 Human IFN-γ ND % 25.2 Human IP % 43.9 ND = Non-detectable 26 Tel:

29 Cell Culture Supernatant LEGENDplex Human Macrophage/Microglia Panel Human monocytes (1 x 10 6 cells/ml) were differentiated using GM-CSF (25 ng/ml) for 5 days. The differentiated macrophages were further polarized using various stimulation agents (100 ng/ml LPS and 25 ng/ml IFN-γ; 20 ng/ml IL-4). Supernatants were collected after 48 hours of culturing and assayed with LEGENDplex TM Human Macrophage/Microglia Panel. The results (all in pg/ml) are summarized below. Analyte Control LPS + IFN-γ IL-4 Human IL-12(p70) Human TNF-α Human IL Human IL * Human IL Human IL-1β Human Arginase Human TARC Human IL-1RA Human IL-12(p40) Human IL Human IFN-γ ** 33.0 Human IP *High signal results from IL-4 added as a stimulant. ** High signal results from IFN-γ added as a stimulant. The cell culture was rested in fresh culture media. The polarized cells were re-stimulated with the same conditions for 48 hours and supernatants were collected and assayed with LEGENDplex TM Human Macrophage/Microglia Panel. The results (all in pg/ml) are summarized below. Analyte Control LPS + IFN-γ IL-4 Human IL-12(p70) Human TNF-α Human IL biolegend.com 27

30 Human IL * Human IL Human IL-1β Human Arginase Human TARC Human IL-1RA Human IL-12(p40) Human IL Human IFN-γ ** 42.4 Human IP *High signal results from IL-4 added as a stimulant. ** High signal results from IFN-γ added as a stimulant. 28 Tel:

31 TROUBLESHOOTING LEGENDplex Human Macrophage/Microglia Panel Problem Possible Cause Solution Bead population shifting upward or downward during acquisition The strong PE signal from high concentration samples or standards may spill over to classification Channel (e.g., FL3/FL4/APC) and mess up the bead separation. Vacuum pressure is insufficient or vacuum manifold does not seal properly. Optimize instrument settings using Kit Setup Beads, and make appropriate compensation between channels. Increase vacuum pressure such that 0.2 ml buffer can be suctioned in 3-5 seconds. Clean the vacuum manifold and make sure no debris on the manifold. Press down the plate on the manifold to make a good seal. Filter plate will not vacuum or some wells clogged s have insoluble particles or sample is too viscous (e.g., serum and plasma samples) Filter plate was used without pre-wet. Centrifuge samples just prior to assay setup and use supernatant. If high lipid content is present, remove lipid layer after centrifugation. may need dilution if too viscous. If some wells are still clogged during washing, try the following: 1). Add buffer to all the wells, pipette up and down the clogged wells and vacuum again. 2). Use a piece of clean wipe, wipe the under side of the clogged wells and vacuum again. 3). Take a thin needle (e.g., insulin needle), while holding the plate upward, poke the little hole under each of the clogged wells and vacuum again. Do not poke too hard or too deep as it may damage the filter and cause leaking. Pre-wet plate with wash buffer before running the assay. biolegend.com 29

32 Insufficient bead count or slow reading Plate leaked High Background Beads inappropriately prepared s cause beads aggregation due to particulate matter or viscosity. Beads were lost during washing for in-tube assay Probe might be partially clogged. Vacuum pressure set too high Plate set directly on table or absorbent towels during incubations or reagent additions Liquid present on the under side of the plate after vacuum Pipette touching and damaged plate filter during additions. Background wells were contaminated Insufficient washes Sonicate bead vials and vortex just prior to addition. Agitate mixed beads intermittently in reservoir while pipetting this into the plate. Centrifuge samples just prior to assay setup and use supernatant. If high lipid content is present, remove lipid layer after centrifugation. may need dilution if too viscous. Make sure beads are spun down by visually check the pellet (beads are in light blue or blue color). Be very careful when removing supernatant during washing. probe may need to be cleaned, or if needed, probe should be removed and sonicated. Adjust vacuum pressure such that 0.2 ml buffer can be suctioned in 3-5 seconds. Do not exceed 10 Hg of vacuum. Set plate on plate holder or raised edge so bottom of filter is not touching any surface. After washing, press down plate firmly on a stack of clean paper towels to dry the underside of the plate. Pipette to the side of wells. Avoid cross-well contamination by changing tips between pipetting when performing the assay using a multichannel pipette. The background may be due to nonspecific binding of SA-PE. Increase number of washes. 30 Debris (FSC/ SSC) during sample acquisition Debris or platelet may exist in sample solution. Tel: Centrifuge samples before analyzing samples. Remove platelet as much as possible.

33 Variation between duplicate samples Low or poor standard curve signal Signals too high, standard curves saturated Beads aggregation Multichannel pipette may not be calibrated or inconsistent pipetting Plate washing was not uniform s may contain particulate matters. The standard was incorrectly reconstituted, stored or diluted Wrong or short incubation time PMT value for FL2/PE set too high Plate incubation time was too long s contain no or below detectable levels of analyte Sonicate and vortex the Beads prior to use. Calibrate Pipette. Ensure good pipetting practice. Prime pipette before use may help. Make sure all reagents are vacuumed out completely in all wash steps. Centrifuge samples just prior to assay setup and use supernatant. If high lipid content is present, remove lipid layer after centrifugation. may need dilution if too viscous. Follow the protocol to reconstitute, store and dilute standard. Double check your calculation. Ensure the time of all incubations was appropriate. Make sure the PMT setting for the reporter channel is appropriate Use shorter incubation time. Make sure the experiment to generate the samples worked. Use proper positive controls. readings are out of range Missed beads populations during reading, or distribution is unequal s concentrations higher than highest standard point. Standard curve was saturated at higher end of curve. may cause some beads to aggregate. Beads populations are not mixed properly Dilute samples and analyze again. Make sure the PMT setting for the reporter channel is appropriate. Use shorter incubation time if incubation time was too long Centrifuge samples just prior to assay setup and use supernatant. If high lipid content is present, remove lipid layer after centrifugation. may need dilution if too viscous. Make sure all bead populations are mixed. and in similar numbers. biolegend.com 31

34 32 Tel:

35 A B C D E F G H PLATE MAP (for in-plate assay) C0 C C0 C C1 C C1 C C2 C C2 C C3 C C3 C biolegend.com 33

36 Enabling Legendary Discovery LEGENDplex Kits are manufactured by BioLegend 9727 Pacific Heights Blvd. San Diego, CA Tel: Tel: US & Canada Toll-Free: Bio-Legend ( ) Fax: biolegend.com For a complete list of world-wide BioLegend offices and distributors, please visit our website at: biolegend.com 75062_V01

LEGENDplex. Please read the entire manual before running the assay. BioLegend.com. Please read the entire manual before running the assay.

LEGENDplex. Please read the entire manual before running the assay. BioLegend.com. Please read the entire manual before running the assay. LEGENDplex Mul -Analyte Mul -Analyte Flow Flow Assay Assay Kit Kit Cat. No. 740005, Mouse Th Cytokine Panel (13-plex ) Cat. No. 740025, Mouse Th1 Panel (5-plex) Cat. No. 740027, Mouse Th2 Panel (6-plex)

More information

Enabling Legendary Discovery. LEGENDplex. LEGENDplex. Mul -Analyte Flow Assay Kit. Mul -Analyte Flow Assay Kit

Enabling Legendary Discovery. LEGENDplex. LEGENDplex. Mul -Analyte Flow Assay Kit. Mul -Analyte Flow Assay Kit Enabling Legendary Discovery LEGENDplex LEGENDplex Mul -Analyte Flow Assay Kit Mul -Analyte Flow Assay Kit Cat. No. 740283, Rat Th Cytokine Panel (13-plex) with Filter plate Cat. No. 740402, Rat Th Cytokine

More information

Enabling Legendary Discovery. LEGENDplex. LEGENDplex. Mul -Analyte Flow Assay Kit

Enabling Legendary Discovery. LEGENDplex. LEGENDplex. Mul -Analyte Flow Assay Kit Enabling Legendary Discovery LEGENDplex LEGENDplex Mul -Analyte Flow Assay Kit Mul -Analyte Flow Assay Kit Cat. No. 740349 Human Anti-Virus Response Panel (13-plex ) with Filter Plate Cat. No. 740390 Human

More information

LEGENDplex. Please read the entire manual before running the assay. BioLegend.com. Please read the entire manual before running the assay.

LEGENDplex. Please read the entire manual before running the assay. BioLegend.com. Please read the entire manual before running the assay. LEGENDplex Mul -Analyte Mul -Analyte Flow Flow Assay Assay Kit Kit Cat. No. 740001, Human Th Cytokine Panel (13-plex ) Cat. No. 740009, Human Th1 Panel (5-plex) Cat. No. 740011, Human Th2 Panel (6-plex)

More information

LEGENDplex Mul -Analyte Flow Flow Assay Kit Kit

LEGENDplex Mul -Analyte Flow Flow Assay Kit Kit Enabling Enabling Legendary Legendary Discovery Discovery LEGENDplex Mul -Analyte Flow Flow Assay Kit Kit Human Proinflammatory Chemokine Mix and Match Subpanel For Accurate Quantification of Multiple

More information

Enabling Legendary Discovery. LEGENDplex. LEGENDplex. Mul -Analyte Flow Assay Kit. Please read the entire manual before running the assay.

Enabling Legendary Discovery. LEGENDplex. LEGENDplex. Mul -Analyte Flow Assay Kit. Please read the entire manual before running the assay. Enabling Legendary Discovery LEGENDplex LEGENDplex Mul -Analyte Flow Assay Kit Mul -Analyte Flow Assay Kit Cat. No. 740251, Rat Inflammation Panel (13-plex) with Filter Plate Cat. No. 740401, Rat Inflammation

More information

LEGENDplex. Cat. No Human Cytokine Panel 2 (13-plex) Please read the entire manual before running the assay.

LEGENDplex. Cat. No Human Cytokine Panel 2 (13-plex) Please read the entire manual before running the assay. LEGENDplex Mul -Analyte Mul -Analyte Flow Flow Assay Assay Kit Kit Cat. No. 740102 Human Cytokine Panel 2 (13-plex) For Accurate Quantification of Multiple Human Th (T helper Cell) Cytokines from Cell

More information

LEGENDplex. Cat. No Human Proinflammatory Chemokine Panel (13-plex) Please read the entire manual before running the assay.

LEGENDplex. Cat. No Human Proinflammatory Chemokine Panel (13-plex) Please read the entire manual before running the assay. LEGENDplex Mul -Analyte Mul -Analyte Flow Flow Assay Assay Kit Kit Cat. No. 740003 Human Proinflammatory Chemokine Panel (13-plex) For Accurate Quantification of Multiple Human Th (T helper Cell) Cytokines

More information

LEGENDplex. Cat. No Human CD8/NK Panel (13-plex ) Please read the entire manual before running the assay.

LEGENDplex. Cat. No Human CD8/NK Panel (13-plex ) Please read the entire manual before running the assay. LEGENDplex Mul -Analyte Mul -Analyte Flow Flow Assay Assay Kit Kit Cat. No. 740267 Human CD8/NK Panel (13-plex ) For Accurate Quantification of Multiple Human Th (T helper Cell) Cytokines from Cell Culture

More information

30 Plex Human Luminex (Invitrogen Kit, Single Plate)

30 Plex Human Luminex (Invitrogen Kit, Single Plate) 30 Plex Human Luminex (Invitrogen Kit, Single Plate) 1. Defrost samples and bring to room temperature. 2. Bring Kit components to room temperature: Wash solution 20x. Assay Diluent. Incubation buffer.

More information

Setup Procedure for Beckman Coulter CytoFLEX Flow Cytometer

Setup Procedure for Beckman Coulter CytoFLEX Flow Cytometer Setup Procedure for Beckman Coulter CytoFLEX Flow Cytometer This part of the guide applies to Beckman Coulter flow cytometers using Cyto- Expert software version 1.2.8 and later. For CytoFLEX flow cytometers,

More information

BoTest Matrix E Botulinum Neurotoxin Detection Kit Protocol

BoTest Matrix E Botulinum Neurotoxin Detection Kit Protocol BoTest Matrix E Botulinum Neurotoxin Detection Kit Protocol 505 S. Rosa Road, Suite 105 Madison, WI 53719 1-608-441-8174 info@biosentinelpharma.com BioSentinel Part No: L1016, Release Date: May 29, 2014

More information

ChIP Protocol for fresh or frozen cross linked cells

ChIP Protocol for fresh or frozen cross linked cells Prior to starting your ChIPs and Shearing Turn on sonifiers and cooling system allow system to reach -2 C before shearing Cool bench top centrifuge to 4 C Prepare all of your buffers with protease inhibitors

More information

Technical Bulletin. Guide for Using BD Cytometric Bead Array (CBA) Flex Sets with the BD Accuri C6 Flow Cytometer. Introduction

Technical Bulletin. Guide for Using BD Cytometric Bead Array (CBA) Flex Sets with the BD Accuri C6 Flow Cytometer. Introduction Guide for Using BD Cytometric Bead Array (CBA) Flex Sets with the BD Accuri C6 Contents 1 Introduction 2 Materials and Methods 3 Setup Procedure Introduction BD Cytometric Bead Array (CBA) flex sets provide

More information

BD OneFlow Setup Beads

BD OneFlow Setup Beads 7/2014 23-15758-00 IVD BD OneFlow Setup Beads 25 tests per kit Catalog No. 658620 BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. 2014 BD Becton, Dickinson and Company

More information

EPIGENTEK. EpiQuik Circulating Cell-Free DNA Isolation Kit. Base Catalog # P-1064 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

EPIGENTEK. EpiQuik Circulating Cell-Free DNA Isolation Kit. Base Catalog # P-1064 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE EpiQuik Circulating Cell-Free DNA Isolation Kit Base Catalog # PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE Uses: The EpiQuik Circulating Cell-Free DNA Isolation Kit utilizes magnetic beads based sizefractionation

More information

DNA extraction Protocol for Agencourt Genfind v2 Blood and Serum Genomic DNA Isolation Kit

DNA extraction Protocol for Agencourt Genfind v2 Blood and Serum Genomic DNA Isolation Kit DNA extraction Protocol for Agencourt Genfind v2 Blood and Serum Genomic DNA Isolation Kit Introduction The Agencourt Genfind v2 Blood & Serum DNA Isolation Kit utilizes Agencourt s patented SPRI paramagnetic

More information

AGENCOURT GENFIND Blood & Serum Genomic DNA Isolation Kit

AGENCOURT GENFIND Blood & Serum Genomic DNA Isolation Kit Blood & Serum Genomic DNA Isolation Kit Page 1 of 9 Please refer to http://www.agencourt.com/technical for updated protocols and refer to MSDS instructions when handling or shipping any chemical hazards.

More information

P R O D U C T I N S E R T

P R O D U C T I N S E R T Immucor GTI Diagnostics, Inc. 09 Crossroads Circle, Waukesha, WI 186 USA Tel: (8) 66-867 WWW.IMMUCOR.COM Product Documentation available at: www.immucor.com P R O D U C T I N S E R T LIFECODES LSA -MIC

More information

Best Practices with the Bio-Plex system. Alasdair I Reid Ph.D. Field Application Specialist Bio-Rad Laboratories

Best Practices with the Bio-Plex system. Alasdair I Reid Ph.D. Field Application Specialist Bio-Rad Laboratories Best Practices with the Bio-Plex system Alasdair I Reid Ph.D. Field Application Specialist Bio-Rad Laboratories Outline of Content How to contact Bio-Rad Start up and Shutdown Procedures Maintenance, Calibration

More information

High Capacity Magne Streptavidin Beads

High Capacity Magne Streptavidin Beads TECHNICAL MANUAL High Capacity Magne Streptavidin Beads Instruc ons for Use of Product V7820 Revised 7/16 TM474 High Capacity Magne Streptavidin Beads All technical literature is available at: www.promega.com/protocols/

More information

RayBio anti-mouse IgG Magnetic Beads

RayBio anti-mouse IgG Magnetic Beads RayBio anti-mouse IgG Magnetic Beads Catalog #: 801-103 User Manual Last revised January 4 th, 2017 Caution: Extraordinarily useful information enclosed ISO 1348 Certified 3607 Parkway Lane, Suite 100

More information

Multiplexing as Essential Tool for Modern Biology

Multiplexing as Essential Tool for Modern Biology Multiplexing as Essential Tool for Modern Biology Bio-Plex Seminar, Debrecen, 2012. Gyula Csanádi, PhD. The "Age of "-omics" Studying interrelationships at different level of complexity Genes - Unveiling

More information

TrueBlot Protein G Magnetic Beads PG ml. TrueBlot Protein G Magnetic Beads PG ml. Bead Mean Diameter 0.5 µm. Bead Concentration

TrueBlot Protein G Magnetic Beads PG ml. TrueBlot Protein G Magnetic Beads PG ml. Bead Mean Diameter 0.5 µm. Bead Concentration Rockland s TrueBlot Protein G Magnetic Beads are uniform, non-aggregating, super-paramagnetic beads coupled with a biomolecule, such as Protein G. These beads are specifically designed, tested and quality

More information

P R O D U C T I N S E R T

P R O D U C T I N S E R T Immucor Transplant Diagnostics, Inc. 550 West Avenue, Stamford, CT 0690 USA Tel: (0) 8-9500 or (888) 9-055, Fax: (0) 8-9599 WWW.IMMUCOR.COM Product Documentation available at: www.immucor.com P R O D U

More information

RayBio mrna Magnetic Beads Kit

RayBio mrna Magnetic Beads Kit RayBio mrna Magnetic Beads Kit Catalog #: 801-116 User Manual Last revised March 9 th, 2017 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite 100 Norcross,

More information

AbC Total Antibody Compensation Bead Kit

AbC Total Antibody Compensation Bead Kit AbC Total Antibody Compensation Bead Kit Catalog nos. A1497, A1513 Table 1. Contents and storage Material A1497 Amount A1513 Composition Storage Stability AbC Total Compensation capture beads (Component

More information

BD FC Beads 7-Color Kit

BD FC Beads 7-Color Kit 7/2016 23-15656-01 IVD BD FC Beads 7-Color Kit 5 tests per kit Catalog No. 656867 2016 BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company. Becton, Dickinson and

More information

Perform instrument startup and verification check following the manufacturer s recommendations.

Perform instrument startup and verification check following the manufacturer s recommendations. Setup procedure for guava easycyte with Two Lasers Important note: The guava instruments are based on microcapillary flow. This technology offers some advantages for general flow cytometry but the instruments

More information

HLA ANTIBODY DETECTION LUMINEX (GEN-PROBE LIFECODES)

HLA ANTIBODY DETECTION LUMINEX (GEN-PROBE LIFECODES) Page 1 of 17 1 PURPOSE HLA ANTIBODY DETECTION LUMINEX (GEN-PROBE LIFECODES) This procedure describes the steps required to detect human IgG antibodies to HLA Class I and Class II antigens using Gen-Probe

More information

BD FC Beads 7-Color Kit

BD FC Beads 7-Color Kit 7/2017 23-19811-00 IVD BD FC Beads 7-Color Kit 5 tests per kit Catalog No. 662961 2017 BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company. Becton, Dickinson and

More information

Technical Manual No. TM0261 Version

Technical Manual No. TM0261 Version Donkey Anti-Goat IgG MagBeads Cat. No. L00332 Technical Manual No. TM0261 Version 06272010 Index 1. Product Description 2. Instruction For Use 3. Troubleshooting 4. General Information 1. Product Description

More information

Perform instrument startup and verification check following the manufacturer s recommendations.

Perform instrument startup and verification check following the manufacturer s recommendations. Setup procedure for guava easycyte with a Single Laser Important note: The guava instruments are based on microcapillary flow. This technology offers some advantages for general flow cytometry but the

More information

10 kb to 20 kb Template Preparation and Sequencing with Low-Input DNA

10 kb to 20 kb Template Preparation and Sequencing with Low-Input DNA Please note: the shared protocols described herein may not have been validated by Pacific Biosciences and are provided as-is and without any warranty. Use of these protocols is offered to those customers

More information

Alon s SCN ChIP Protocol

Alon s SCN ChIP Protocol Prior to starting your ChIPs and Shearing 1. Turn on sonifiers and cooling system allow system to reach -1 C before shearing 2. Cool bench top centrifuge to 4 C 3. Prepare all of your buffers with protease

More information

Procedure & Checklist Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing

Procedure & Checklist Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing Procedure & Checklist Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing Before You Begin This document describes a procedure for multiplexing 5 Mb microbial genomes

More information

P R O D U C T I N S E R T

P R O D U C T I N S E R T Immucor GTI Diagnostics, Inc. 095 Crossroads Circle, Waukesha, WI 5186 USA Tel: (855) 466-867 WWW.IMMUCOR.COM Product Documentation and Translations available at: www.immucor.com P R O D U C T I N S E

More information

illumina TruSeq RNA Sample Prep. (LT) Protocol 1

illumina TruSeq RNA Sample Prep. (LT) Protocol 1 illumina TruSeq RNA Sample Prep. (LT) Protocol 1 Performed using the TruSeq RNA Sample Preparation Kit (A cat#fc-122-1001, B cat#fc122-1002) Purify and Fragment mrna NOTE: Use 3ug of Total RNA to initiate

More information

Bio-Plex Pro Magnetic COOH Beads Bio-Plex COOH Beads Amine Coupling Kit Instruction Manual

Bio-Plex Pro Magnetic COOH Beads Bio-Plex COOH Beads Amine Coupling Kit Instruction Manual Bio-Plex Pro Magnetic COOH Beads Bio-Plex COOH Beads Amine Coupling Kit Instruction Manual For technical service, call your local Bio-Rad office, or in the U.S. call 1-800-424-6723. For research use only.

More information

PARP1-Trap_A for Immunoprecipitation of PARP1- Fusion Proteins from cell extract

PARP1-Trap_A for Immunoprecipitation of PARP1- Fusion Proteins from cell extract PARP1-Trap_A for Immunoprecipitation of PARP1- Fusion Proteins from cell extract Only for research applications, not for diagnostic or therapeutic use. Introduction Specificity Poly(ADP-ribose) polymerase

More information

BD Trucount Controls IVD

BD Trucount Controls IVD BD Trucount Controls To control certain elements of the absolute counting process 3/2016 23-3537-05 IVD 30 Tests Catalog No. 340335 2016 BD. BD, the BD Logo and all other trademarks are property of Becton,

More information

JetSeq Clean. Product Manual

JetSeq Clean. Product Manual JetSeq Clean Product Manual 2 Product Manual bioline.com/jetseq JetSeq Clean JetSeq Clean TABLE OF CONTENTS 1 Kit contents 04 2 Description 05 3 Equipment and reagents to be supplied by user 06 4 Storage

More information

Additional reagents and materials that are not supplied

Additional reagents and materials that are not supplied sparq PureMag Beads Cat. No. 95196-005 Size: 5 ml Store at 2 C to 8 C 95196-060 60 ml 95196-450 450 ml Description sparq PureMag Beads uses reversible nucleic acid-binding properties of magnetic beads

More information

Procedure and Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System

Procedure and Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System Procedure and Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System Before You Begin To perform this procedure, you must have the PacBio Template Prep Kit and have reviewed the

More information

AGENCOURT ORAPURE Buccal Cell DNA Isolation Kit

AGENCOURT ORAPURE Buccal Cell DNA Isolation Kit Buccal Cell DNA Isolation Kit Page 1 of 12 Please refer to http://www.agencourt.com/technical for updated protocols and refer to MSDS instructions when handling or shipping any chemical hazards. AGENCOURT

More information

pluribead KIT Cell Separation Protocol M-Bead

pluribead KIT Cell Separation Protocol M-Bead pluribead KIT Cell Separation Protocol M-Bead pluriselect@hiss-dx.de 15 14 13 12 11 9 8 7 6 5 4 3 2 1 50 40 30 20 2 Contents Contents pluribead Kit Components & Additional Materials 2 Separation Protocol

More information

Procedure & Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System

Procedure & Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System Procedure & Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System Before You Begin To perform this procedure, you must have the PacBio DNA Template Prep Kit 2.0 (3 kb to 10 kb)

More information

Determination of reagent cross-reactivity. When adding a new, candidate protein to an

Determination of reagent cross-reactivity. When adding a new, candidate protein to an This journal is The Royal Society of Chemistry 23 Supplementary Information Supplementary Text Determination of reagent cross-reactivity. When adding a new, candidate protein to an existing multiplexed

More information

mag maxi kit Intended use of the mag maxi kits

mag maxi kit Intended use of the mag maxi kits mag maxi kit For in vitro diagnostic use 40403 40430 10 288 May 2014 LGC Genomics GmbH Ostendstr. 25 TGS Haus 8 12459 Berlin Germany Tel: +49 (0)30 5304 2200 Fax: +49 (0)30 5304 2201 Intended use of the

More information

mi-mag mrna Isolation Kit

mi-mag mrna Isolation Kit mi-mag mrna Isolation Kit Cat. No [50 Reactions] This kit is for research purposes only. Not for use in diagnostic procedures. For in vitro use only. Introduction This kit contains enough materials for

More information

Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085

Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085 INSTRUCTION MANUAL Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085 Highlights Tunable: Size selection can be tuned from 100 bp to 1000 bp with left, right, or double size selection

More information

NGS clean-up and size selection

NGS clean-up and size selection NGS clean-up and size selection User manual NucleoMag NGS Clean-up and Size Select May 2014 / Rev. 01 NGS clean-up and size selection Table of contents 1 Components 4 1.1 Kit contents 4 1.2 Equipment and

More information

SOP-P094. BioMek 2000 Compound Protocol Cyan/Hypercyt + Analysis

SOP-P094. BioMek 2000 Compound Protocol Cyan/Hypercyt + Analysis SOP-P094 BioMek 2000 Compound Protocol Cyan/Hypercyt + Analysis Objective: To test serial dilutions of certain compounds Protocol for half plate runs only. One plate of Redox dye and the other plate -

More information

chemagic mrna Direct Kit

chemagic mrna Direct Kit chemagic mrna Direct Kit for general purposes Kit for the direct isolation of mrna from animal and plant tissue and cells. Kit Components M-PVA OdT Magnetic Beads Suspension Buffer 1 Lysis Buffer 2 Wash

More information

Formaldehyde Cross-linking of Chromatin from Drosophila

Formaldehyde Cross-linking of Chromatin from Drosophila 2 Formaldehyde Cross-linking of Chromatin from Drosophila Protocol from modencode IGSB University of Chicago originally written by Alex Crofts and Sasha Ostapenko and updated by Matt Kirkey. 1. Set centrifuge

More information

AdnaTest EMT-1/StemCellSelect

AdnaTest EMT-1/StemCellSelect AdnaTest EMT-1/StemCellSelect Enrichment of tumor cells from blood for gene expression analysis For research use only Manual T-1-533 Contents Order Information... 3 Purpose... 3 Abbreviations and Symbols...

More information

Illumina TruSeq Stranded mrna (LT) Protocol 1

Illumina TruSeq Stranded mrna (LT) Protocol 1 Illumina TruSeq Stranded mrna (LT) Protocol 1 Performed using the TruSeq Stranded mrna Sample Preparation Kit (A cat#fc-122-2101, B cat#fc122-2102) Purify and Fragment mrna NOTE: Use 500ng of Total RNA

More information

AdnaTest OvarianCancer-2 Select

AdnaTest OvarianCancer-2 Select AdnaTest OvarianCancer-2 Select Enrichment of tumor cells from blood of ovarian cancer patients for gene expression analysis For research use only Manual T-1-538 Contents Order Information... 3 Purpose...

More information

ab Firefly Cytometer Setup Particles

ab Firefly Cytometer Setup Particles Version 1 Last updated 12 October 2016 ab211043 Firefly Cytometer Setup Particles For cytometer performance optimization for use with Firefly Multiplex particles. This product is for research use only

More information

VeriPlex TM Human Cytokine 16-Plex ELISA Kit

VeriPlex TM Human Cytokine 16-Plex ELISA Kit VeriPlex TM Human Cytokine 16-Plex ELISA Kit Catalog No. 51510 Store all components at 2-8 C We recommend reading the protocol in its entirety prior to use. First time users must pay particular attention

More information

Procedure & Checklist - 2 kb Template Preparation and Sequencing

Procedure & Checklist - 2 kb Template Preparation and Sequencing Procedure & Checklist - 2 kb Template Preparation and Sequencing Before You Begin To perform this procedure, you must have the PacBio DNA Template Prep Kit (verify you have the correct kit for your insert

More information

empcr Amplification Method Manual Lib L LV

empcr Amplification Method Manual Lib L LV empcr Amplification Method Manual Lib L LV GS FLX+ Series XL+ May 2011 For life science research only. Not for use in diagnostic procedures. Instrument / Kit GS Junior / Junior GS FLX+ / XL+ GS FLX+ /

More information

Procedure & Checklist - 1 kb Template Preparation and Sequencing

Procedure & Checklist - 1 kb Template Preparation and Sequencing Procedure & Checklist - 1 kb Template Preparation and Sequencing Before You Begin To perform this procedure, you must have the PacBio Template Prep Kit. Fragment and Concentrate DNA Important: The distribution

More information

Procedure & Checklist - 10 kb Template Preparation and Sequencing (with Low-Input DNA)

Procedure & Checklist - 10 kb Template Preparation and Sequencing (with Low-Input DNA) Procedure & Checklist - 10 kb Template Preparation and Sequencing (with Low-Input DNA) Before You Begin To perform this procedure, you must have the PacBio : Template Prep Kit DNA/Polymerase Binding Kit

More information

Strep-tag Purification using MagStrep type3 XT Beads

Strep-tag Purification using MagStrep type3 XT Beads Strep-tag Purification using MagStrep type3 XT Beads Instruction manual Last date of revision November 2016 Version PR83-0004 For research only Important licensing information Products featuring Strep-Tactin

More information

Strep-tag Purification using MagStrep type3 XT Beads

Strep-tag Purification using MagStrep type3 XT Beads Strep-tag Purification using MagStrep type3 XT Beads Instruction manual Last date of revision April June 2014 2012 Version PR24-0001 PR83-0004 www.strep-tag.com For research only Important licensing information

More information

Procedure & Checklist - 10 kb Template Preparation and Sequencing

Procedure & Checklist - 10 kb Template Preparation and Sequencing Procedure & Checklist - 10 kb Template Preparation and Sequencing Before You Begin To perform this procedure, you must have the PacBio Template Prep Kit. This procedure can be used to prepare 10 kb libraries

More information

Procedure & Checklist bp Amplicon Library Preparation and Sequencing

Procedure & Checklist bp Amplicon Library Preparation and Sequencing Procedure & Checklist - 250 bp Amplicon Library Preparation and Sequencing Before You Begin To perform this procedure, you must have the PacBio Template Prep Kit. This procedure is optimized for SMRTbell

More information

capabilities today. Flexibility for tomorrow.

capabilities today. Flexibility for tomorrow. capabilities today. Flexibility for tomorrow. NEW CellStream benchtop flow cytometry system with Amnis detection technology inside The life science business of Merck KGaA, Darmstadt, Germany operates as

More information

Procedure & Checklist bp Template Preparation and Sequencing

Procedure & Checklist bp Template Preparation and Sequencing Procedure & Checklist - 500 bp Template Preparation and Sequencing Before You Begin To perform this procedure, you must have the PacBio Template Prep Kit. This procedure is optimized for SMRTbell template

More information

Strep-tag Purification using MagStrep type3 XT Beads

Strep-tag Purification using MagStrep type3 XT Beads Strep-tag Purification using MagStrep type3 XT Beads Instruction manual Last date of revision November 2016 Version PR83-0004 For research only Important licensing information Products featuring Strep-Tactin

More information

Mag-Bind cfdna Kit. M preps M preps M Preps

Mag-Bind cfdna Kit. M preps M preps M Preps Mag-Bind cfdna Kit M3298-00 5 preps M3298-01 50 preps M3298-02 200 Preps March 2018 Mag-Bind cfdna Kit Table of Contents Introduction and Overview...2 Kit Contents/Storage and Stability...3 Preparing Reagents...4

More information

Procedure & Checklist - Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing

Procedure & Checklist - Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing Procedure & Checklist - Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing Before You Begin This document describes methods for generating SMRTbell libraries using

More information

LOABeads AffiAmino. Product Manual. Lab on a Bead AB. Revision date Copyright Lab on a Bead AB All rights reserved

LOABeads AffiAmino. Product Manual. Lab on a Bead AB. Revision date Copyright Lab on a Bead AB All rights reserved LOABeads AffiAmino Product Manual Lab on a Bead AB Revision date 2016-11-23 Copyright 2015-2016 Lab on a Bead AB All rights reserved Table of Contents 1. General information...3 2. Product data...4 3.

More information

USER GUIDE For Illumina Platform

USER GUIDE For Illumina Platform USER GUIDE For Illumina Platform Copyright Nimagen B.V. P.O. Box 91 6500 AB Nijmegen The Netherlands Tel. +31 (0)24 820 0241 Fax. +31 (0)24 358 0259 info@nimagen.com VAT#: NL850011243B01 Rabobank Nijmegen:

More information

M-Beads Magnetic Silica Beads WAX

M-Beads Magnetic Silica Beads WAX M-Beads Magnetic Silica Beads WAX MoBiTec GmbH 2012 Page 2 Contents Technical data... 3 Application... 4 General information... 4 Bead usage... 4 Additional materials needed... 4 Protocols... 5 Order Information,

More information

Total RNA Isolation. User Manual. NucleoMag 96 RNA MACHEREY-NAGEL. January 2010 / Rev. 02

Total RNA Isolation. User Manual. NucleoMag 96 RNA MACHEREY-NAGEL. January 2010 / Rev. 02 Total RNA Isolation User Manual NucleoMag 96 RNA January 2010 / Rev. 02 MACHEREY-NAGEL Table of contents 1 Components 4 1.1 Kit contents 4 1.2 Material to be supplied by user 5 2 Product description 6

More information

LOABeads MagSep 15/50 LOABeads MagSep 500

LOABeads MagSep 15/50 LOABeads MagSep 500 LOABeads MagSep 15/50 LOABeads MagSep 500 Product Manual Lab on a Bead AB Edition 2016-05-09 Copyright 2015-2016 Lab on a Bead AB Table of Contents 1. 2. 3. 4. 5. 6. Safety instructions...3 General handling

More information

MinION PROTOCOL. Adapted from Janneke Wit by Robyn Tanny May Company Kit/Item Catalog Number

MinION PROTOCOL. Adapted from Janneke Wit by Robyn Tanny May Company Kit/Item Catalog Number MinION PROTOCOL Adapted from Janneke Wit by Robyn Tanny May 2016 Company Kit/Item Catalog Number Fisher Eppendorf DNA/RNA LoBind Tubes 13-698-791 Fisher Covaris g-tube NC0380758 NEB NEBNext FFPE Repair

More information

Caution: For Laboratory Use. A product for research purposes only. YSi (2 5 μm) Copper His-Tag SPA Beads. Product Numbers: RPNQ0096

Caution: For Laboratory Use. A product for research purposes only. YSi (2 5 μm) Copper His-Tag SPA Beads. Product Numbers: RPNQ0096 TECHNICAL DATA SHEET SPA Beads Caution: For Laboratory Use. A product for research purposes only. YSi (2 5 μm) Copper His-Tag SPA Beads Product Numbers: RPNQ0096 WARNING For research use only. Not recommended

More information

NEBNext DNA Library Prep Master Mix Set for Illumina

NEBNext DNA Library Prep Master Mix Set for Illumina LIBRARY PREPARATION NEBNext DNA Library Prep Master Mix Set for Illumina Instruction Manual NEB #E6040S/L 12/60 reactions Version 8.0 9/18 be INSPIRED drive DISCOVERY stay GENUINE This product is intended

More information

Procedure & Checklist - Greater Than 10 kb Template Preparation Using AMPure PB Beads

Procedure & Checklist - Greater Than 10 kb Template Preparation Using AMPure PB Beads Procedure & Checklist - Greater Than 10 kb Template Preparation Using AMPure PB Beads Before You Begin This procedure can be used to prepare greater than 10 kb libraries from 5 μg of sheared and concentrated

More information

xgen hybridization capture of DNA libraries

xgen hybridization capture of DNA libraries xgen hybridization capture of DNA libraries For NGS target enrichment Uses IDT s: xgen Hybridization and Wash Kit xgen Universal Blockers TS Mix, 10 bp TS Mix, or NXT Mix xgen Lockdown Panels and Probes

More information

Procedure & Checklist - cdna Capture Using SeqCap EZ Libraries

Procedure & Checklist - cdna Capture Using SeqCap EZ Libraries Procedure & Checklist - cdna Capture Using SeqCap EZ Libraries Before You Begin This document describes the process for capturing cdna prepared with the SMARTer PCR cdna Synthesis Kit (Clontech) and pulled-down

More information

Procedure & Checklist Preparing Multiplexed Microbial SMRTbell Libraries for the PacBio Sequel System

Procedure & Checklist Preparing Multiplexed Microbial SMRTbell Libraries for the PacBio Sequel System Procedure & Checklist Preparing Multiplexed Microbial SMRTbell Libraries for the PacBio Sequel System Before You Begin This procedure is for preparing multiplexed SMRTbell libraries for sequencing on the

More information

VAHTS Stranded mrna-seq Library Prep Kit for Illumina

VAHTS Stranded mrna-seq Library Prep Kit for Illumina Instruction Manual VAHTS Stranded mrna-seq Library Prep Kit for Illumina Vazyme Cat #NR602 Vazyme Biotech Co., Ltd Web: www.vazyme.com Tel: 400-600-9335 Sales: Sales@vazyme.com Support: Support@ vazyme.com

More information

Microwell-Seq. High-throughput Single Cell RNA-Seq Kit. Protocol. Index

Microwell-Seq. High-throughput Single Cell RNA-Seq Kit. Protocol. Index Microwell-Seq High-throughput Single Cell RNA-Seq Kit Protocol Index 1 Introduction 2 Kit Reagent 3 Store 4 Application 5 Prepared materials 6 Note 7 Preparation 8 Workflow 1 1 Introduction Microwell-Seq

More information

ChargeSwitch gdna Blood Kits

ChargeSwitch gdna Blood Kits Instruction Manual ChargeSwitch gdna Blood Kits For purification of genomic DNA from small volumes of human blood Catalog nos. CS11000, CS11010, and CS11010-10 Version A 6 January 2005 25-0814 ii Table

More information

We want to thank and acknowledge the authors for sharing this protocol and their contributions to the field.

We want to thank and acknowledge the authors for sharing this protocol and their contributions to the field. We adopted the protocol described in the Extended Experimental Procedures section I.a.1 of the 2014 Cell paper by Rao and Huntley et. al: A 3D Map of the Human Genome at Kilobase Resolution Reveals Principles

More information

DNA Size Selection Magnetic Beads

DNA Size Selection Magnetic Beads DNA Size Selection Magnetic Beads Catalog #: 801-117 User Manual Last revised July 30 th, 2018 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite 100 Norcross,

More information

Supporting Information:

Supporting Information: Electronic Supplementary Material (ESI) for Chemical Science. This journal is The Royal Society of Chemistry 2014 Supporting Information: Plasmonic Micro-Beads for Fluorescence Enhanced, Multiplexed Protein

More information

Procedure & Checklist >20 kb Template Preparation Using BluePippin Size-Selection System (15-20 kb Cutoff) for Sequel Systems

Procedure & Checklist >20 kb Template Preparation Using BluePippin Size-Selection System (15-20 kb Cutoff) for Sequel Systems Procedure & Checklist >20 kb Template Preparation Using BluePippin Size-Selection System (15-20 kb Cutoff) for Sequel Systems Before You Begin To perform this procedure, you must have the PacBio Template

More information

When to Perform the Test CCD 4-Color and/or Seq Fill Capillary Run Modules

When to Perform the Test CCD 4-Color and/or Seq Fill Capillary Run Modules To navigate within this document use the or keys ABI PRISM 310 Genetic Analyzer Test CCD 4-Color and Seq Fill Capillary Run Modules BEFORE PERFORMING ANY TROUBLESHOOTING WORK ON YOUR ABI PRISM 310 GENETIC

More information

Direct Polysome IP from Brain Tissue Myriam Heiman:

Direct Polysome IP from Brain Tissue Myriam Heiman: Direct Polysome IP from Brain Tissue Myriam Heiman: bonillm@rockefeller.edu Protocol below is for 1 IP, scale accordingly General Notes: -7 mouse striata pooled per IP -IP with 50 µg 19C8 and 50 µg 19F7

More information

P R O D U C T I N S E R T

P R O D U C T I N S E R T Immucor GTI Diagnostics, Inc. 095 Crossroads Circle, Waukesha, WI 518 USA Tel: (855) 4-87 WWW.IMMUCOR.COM Product Documentation and Translations available at: www.immucor.com LIFECODES Class I ID: A Luminex

More information

Procedure & Checklist cdna Capture Using IDT xgen Lockdown Probes

Procedure & Checklist cdna Capture Using IDT xgen Lockdown Probes Procedure & Checklist cdna Capture Using IDT xgen Lockdown Probes Before You Begin This document describes the process for capturing cdna prepared with the SMARTer PCR cdna Synthesis Kit (Clontech) and

More information

BIOL110L-Cell Biology Lab Spring Quarter 2012 Module 3-4 Wednesday May 30, 2012

BIOL110L-Cell Biology Lab Spring Quarter 2012 Module 3-4 Wednesday May 30, 2012 BIOL110L-Cell Biology Lab Spring Quarter 2012 Module 3-4 Wednesday May 30, 2012 PART I: Isolation of over-expressed GFP-Karyopherins from yeast extracts by affinity capture on nucleoporins Summary: The

More information

DNA/RNA Extraction Kit

DNA/RNA Extraction Kit Kit Primerdesign Ltd genesig Easy DNA/RNA Extraction Kit 50 extractions Universal kit for isolation of RNA / DNA from food, water, clinical, veterinary and other samples types. DNA Testing For general

More information

Downloaded from:

Downloaded from: Corran, PH; Cook, J; Lynch, C; Leendertse, H; Manjurano, A; Griffin, J; Cox, J; Abeku, T; Bousema, T; Ghani, AC; Drakeley, C; Riley, E (2008) Dried blood spots as a source of anti-malarial antibodies for

More information

M-Beads Magnetic silica beads DNA 3.0 (COOH) Order #: PR-MAG00078 & PR-MAG00079

M-Beads Magnetic silica beads DNA 3.0 (COOH) Order #: PR-MAG00078 & PR-MAG00079 M-Beads Magnetic silica beads DNA 3.0 (COOH) Order #: PR-MAG00078 & PR-MAG00079 MoBiTec GmbH 2015 Page 2 Contents Intended Use... 3 Principle... 3 Silica & Carboxylated M-Beads Magnetic silica beads DNA