A SEGMENTED CAPACITANCE TOMOGRAPHY FOR VISUALISING MATERIAL DISTRIBUTIONS IN PIPELINE CONVEYING CRUDE PALM OIL

Size: px
Start display at page:

Download "A SEGMENTED CAPACITANCE TOMOGRAPHY FOR VISUALISING MATERIAL DISTRIBUTIONS IN PIPELINE CONVEYING CRUDE PALM OIL"

Transcription

1 A SEGMENTED CAPACITANCE TOMOGRAPHY FOR VISUALISING MATERIAL DISTRIBUTIONS IN PIPELINE CONVEYING CRUDE PALM OIL Prepared by: Prof Dr. Ruzairi Abdul Rahim (UTM), Dr. Elmy Johana Mohamad, A segmented electrical capacitance tomography (ECT) imager for palm oil process monitoring system is constructed and presented in this work.the goal of this study is to use the process monitoring system as an instrument to upkeep the local and foreign palm oil mill. This is to ensure that the monitoring of crude palm oil (CPO) in conveying pipeline during extraction of palm oil mill process flow process is efficiently controlled. The system has the capability to visualize the percentage of liquid that exist within the vessel therefore the data can be utilized to design and create better process equipment in mill process. It will also be used to control some processes in order to boost the quality of crude palm oil and the POME (Palm Oil Mill Effluent) treatment process. Most ECT in earlier research were created rapidly and utilized well in multiphase flow measurement in numerous applications such as in oil and gas industries, gas/solids cyclone, milk flows and fluidized beds. Experimentally, this work investigates the capability of using a twin-plane segmented ECT sensor with 16 portable electrodes using two differential excitation potentials transmitted signal in order to recognize the concentration and velocity profile as well as the phase concentration of crude palm oil related multiphase systems (liquid and gas). The attained concentration profile which is received from the capacitance measurements is capable to provide image of the liquid and gas mixture in t h e pipeline therefore, the separation process (between oil and liquid waste) becomes much easier and the crude palm oil s quality can be dependably monitored. The visualization results deliver information regarding the flow regime, superficial velocity and concentration distribution in two-phase flowrate measurement system incorporating a liquid flow measuring device. The information obtained is able to help in the process equipment designing, verification of existing computational modeling and simulation techniques. It may also assist in process control and monitoring during the palm oil extraction process.

2 FOREWORD Chief Editor, Prof Ruzairi EDITORIAL BOARD Advisor: Dr Jaafar Abdullah Chief Editor: Prof Dr Hj Ruzairi Abdul Rahim Editors: Assoc. Prof. Ir. Dr. Idris Ismail Engku Mohd Fahmi Engku Chik Assoc Prof Dr Mohd Hezri Fazalul Rahiman Dr Mohd Hafiz Fazalul Rahiman Dr Zulkarnay Zakaria Dr Elmy Johana Mohamad Mohd Amirul Syafiq Mohd Yunos Dr Nurlaila Ismail Johari Yap Graphic Design: Jaysuman Bismillahirrahmanirrahim Welcome Year 2016! May the new year brings everyone courage, resolution early and new inspiran. January 2016 marks significant history for Malaysian Society for Computed Tomography and Imaging Technology (MyCT) as in this month, the first issue of MyCT Bulletin is published. It is a good indicator for every member to be more proactive and productive in their research especially in highlighting and contributing computed tomography not only in country but to the international level. This issue of bulletin highlights the vital of tomography and its related techniques in instrumentation especially for process control and monitoring. The technique exists as problems solve assistance in palm oil plantation, industrial process column and crude oil application. Through previous activities; workshop, exhibition and knowledge sharing provided an opportunity for knowledge exchanging and networking within researchers, thus bridged computed tomography as importance in future imaging application. Last but not least, I, wishing all a happy prosperous fun filled joyful and fortunate New Year!! PAGE CONTENT A Segmented Capacitance Tomography For Visualising Material Distributions In Pipeline Conveying Crude Palm Oil Wire-Mesh Tomography Magnetic Induction Tomography Z-score for Agarwood Oil Quality Discrimination Wins Gold and Industry Choice Award in Innovation, Invention And Design (IID FKE) 2015 Tomography Workshop at Universiti Tun Hussein Onn Malaysia Knowledge Sharing on Computed Tomography from BAM Institute Berlin German Real-Time Measurement of Gas Voids in Waxy Crude Oil via ECT Thank you. Prof Dr Ruzairi Abdul Rahim, Chief Editor 2 Malaysia Society for Computed Tomography & Imaging Technology

3 TOMOGRAPHY WORKSHOP AT UNIVERSITI TUN HUSSEIN ONN MALAYSIA Prepared by: Dr Elmy Johana Mohamad, On 27th of September 2015, the workshop Course on Basic Introduction of Tomography & Image Reconstruction using Visual Basic was held at Makmal Teknologi Komputer, Universiti Tun Hussein Onn Malaysia (UTHM). The workshop aimed at introducing tomography and the basics of its simulation study to the participants. They were also given a hands-on tutorial on reconstructing tomography images using Visual Basic. The workshop was presented by the especially invited tomography expert from Universiti Perlis Malaysia (UniMAP), P.M. Dr. Mohd Hafiz Fazalul Rahiman and was attended by a total of 17 participants (5 UTHM staffs, 5 postgraduate students and 7 undergraduate MAGNETIC INDUCTION TOMOGRAPHY Prepared by: Dr. Zulkarnay Zakaria, zulkarnay@unimap.edu.my A study of magnetic induction tomography (MIT) applications in steel imaging has been done by Universiti Malaysia Perlis lead by Dr. Zulkarnay Zakaria. MIT is a soft field modality which fall under the category of passive imaging modality together with ECT, EIT and magneto static [1]. MIT uses the principle of magnetic induction in reconstructing the image of the object of interest based on its conductivity distribution within the object itself [2]. Figure 1: Position of the sample movements In this research, the developed MIT system consists of 8 pairs of transmitter-receiver arrange as shown in Figure 1 [3]. In this experiment, two steel samples have been arranged at the opposite sides starting from (-10,+10) to (-4,+4) within the region of interest of 26.8 cm in diameter. Four sizes of the samples (1.25, 1.50, 1.75 and 2.00 inch) have been tested in this testing. The reconstructed images shown in Figure 2 proofs that this MIT prototype system is capable of detecting the location of steel samples correctly if the distance between each steel is minimum of 16 cm, otherwise the image tends to combine. Quick improvement that can be made to enhance the resolution performance of system is through the use of transceiver sensors instead of fix transmitter-receiver pairs. 3 Malaysia Society for Computed Tomography & Imaging Technology Figure 1: Reconstructed images of the two steel samples at different distances

4 KNOWLEDGE SHARING ON COMPUTED TOMOGRAPHY FROM BAM INSTITUTE BERLIN GERMAN Prepared by: Dr. Rasif bin Mohd Zain, Engku Mohd Fahmi bin Engku Chik, Digital Industrial Radiography (DIR) and Computed Tomography (CT) have emerged as the future of imaging application in Non-Destructive Testing (NDT). DIR technique differs from conventional radiography in which they use digital detectors to restore digitized images. Meanwhile, X-ray and gamma-ray CT produce by computer processed combination of many DIR images taken from different angles to represent cross-sectional images (virtual slice) of specific areas. image in CT. At present, several codes and standards such as EN, ASTM and ISO have been developed for DIR applications. Deep understanding of these codes and standards is necessary to meet the requirements needed for detector selection and image quality of various digital detectors. Due to this reason, on 22nd November 2015, Malaysian Society for Non Destructive Testing (MSNT) through Malaysia International NDT Conference and Exhibition 2015 (MINDTCE-15) offer a Tomography and Image analysis of Tomogram. This workshop conducted by Dr. Uwe Zscherpel from BAM Berlin German. His area of expertise is digital image processing in industrial radiology, including NDT film digitization, digital image analysis, pattern recognition, and digital reference catalogues for welding and casting. During the workshop Dr. Uwe also share ISee software version to all Various types of digital detectors have becoming available with the advancement of the imaging system. For instance, Computed Radiography, Flat Panel or Fluoroscopy is the most widely used in industries. These digital detectors system allow the users to perform image processing for image enhancement, defect recognition and processing CT. The technology offer high energy radiation applications ranges from 10 kv to several MeV. In DIR system, the main advantage is its ability to significantly reduce the radiation dose in comparison to film applications. In view of this perspective, DIR has attracted the interest of NDT communities and researchers around the world especially in the R&D sector as well as for the industrial applications. NDT communities also realize the potential of this system due to other benefits which it can offer i.e. automatic defect detection, reusability, environmental friendly, digitally formatted and post processing freedom also capable to produce 3D Pre-Conference Workshop on Status, Technologies and Applications to provide an insight into the world of DIR and understanding the codes and standard as their guidelines during inspections or R&D activities. This one day workshop opens to local and international participants. Total participant from local are 17 and 6 from international. Two boards of member and one members of MyCT participated in this workshop and also involved in steering committee of MINDTCE The two of MYCT boards of members involved are YM. Engku Mohd Fahmi Bin Engku Chik and En. Mohd Amirul Syafiq B Mohd Yunos. Meanwhile the MyCT members participated in this workshop is Dr. Rasif B Mohd Zain. The topics cover in this one day workshop are; current status on DIR technologies and standard, Software and tools for DIR, DIR with computed radiography, DIR with digital detector arrays (DDA), exposure requirements for DIR, Inspection of welded components by DIR, DIR for Computer participants. This software allows the computer-aided analysis of digital images via measurements of profiles, wall thickness differences and local corrosions, the storage of results and statistical evaluation of image regions (by mean value, standard deviation and normalized signal-to-noise ratio). The software was developed at BAM Berlin to promote new applications of Digital Industrial Radiology (DIR) and as a vendor-independent program to realize measurements defined in various CEN, ISO and ASTM standards for Non-destructive testing (NDT) with radiological methods. 4 Malaysia Society for Computed Tomography & Imaging Technology

5 WIRE-MESH TOMOGRAPHY Prepared by: Dr. Mohd Hafiz Fazalul Rahiman Experimental studies have been carried out to study the principle operation of the conductive type wire-mesh tomography sensor for liquid/gas two-phase flow interface and void fraction distribution in a process column. The study was conducted by Universiti Malaysia Perlis tomography researcher lead by Dr. Mohd Hafiz Fazalul Rahiman. The measurement of the two-phase flows in the process column is based on the cross-sectional local instantaneous conductivity. The sensor consists of two planes of parallel electrode wires with 16 electrodes each and was placed orthogonally with each plane. The wire-mesh sensor has been tested in a horizontal liquid/gas two-phase flows process column with nominal diameter of 95.6 mm. The tomogram results show that the wire-mesh tomography provides significant results to represent the void fraction distribution in the process column. Void Fraction Phantom Tomogram References [1] H.-M. Prasser, A. Böttger, and J. Zschau, A new electrode-mesh tomograph for gas liquid flows, Flow Meas. Instrum., vol. 9, no. 2, pp , Jun A [2] Rahiman, M. H. F., Siow, L. T., Rahim, R. A., Zakaria, Z., & Ang, V. (2015). Initial study of a wire mesh tomography sensor for Liquid/ Gas component Investigation. Journal of Electrical Engineering and Technology, 10(5), A L = 100% A L = 96.76% B A L = 74.23% A L = 77.88% C A L = 46.67% A L = 52.78% Simplified scheme of the electrode-mesh device as proposed by Prasser et al. [1] D A L = 0% A L = 0% Illustrations of the void fraction, phantom and the tomogram Front-view of WMS Fixture [2] 5 Malaysia Society for Computed Tomography & Imaging Technology Top-view of WMS Sensor [2]

6 Z-SCORE FOR AGARWOOD OIL QUALITY DISCRIMINATION WINS GOLD AND INDUSTRY CHOICE AWARD IN INNOVATION, INVENTION AND DESIGN (IID FKE) 2015 Prepared by: Assoc. Prof. Dr. Mohd Hezri Fazalul Rahiman, Dr Nurlaila Ismail, This project was the outcome of collaboration between UiTM, the Forest Research Institute Malaysia (FRIM) and Universiti Malaysia Pahang (UMP). Instead of that, it also have several accomplishments include a copyright, writing a chapter in a book, several indexed journal, besides attaining international recognition. result in discriminating agarwood oil to high and low quality. It is important and useful in solving the grading agarwood oil system which is currently done manually. On 24th November 2015, Faculty of Electrical Engineering (FKE), Universiti Teknologi MARA, Shah Alam, was organized an innovation event called as INNOVATION, INVENTION AND DESIGN (IID FKE) This yearly event has been participated among lectures and students from various departments in the faculty. This year, a total of 58 projects were participated under categories innovation, invention and design. Two faculty members also from Malaysian Society for Computed Tomography and Imaging Technology (MyCT) Assoc. Dr Mohd Hezri Fazalul Rahiman and Dr Nurlaila Ismail had won two awards which are Gold and Industry Choice Award. These awards were given by Dean of Faculty of Electrical Engineering, Prof Dr Mohd Nasir Taib. The project titled Z-SCORE for agarwood oil quality discrimination basically is a chemical profiles based in discriminating agarwood oil to the high and low quality. The agarwood oil samples are analyzed by Gas Chromatography-Mass Spectrometry (GC-MS) in examining their chemical profiles. The extraction showed that at least forty three volatile compounds are found. Z-SCORE is found successful to identify the significant chemical compounds of the agarwood oils. The chemical compounds are β-agarofuran, α-agarofuran, 10-epi-ɤ-eudesmol, αeudesmol, dihydrocollumellarin and ɤ-eudesmol. These volatile compounds have different abundances pattern responsible to the different qualities of agarwood oil such as high and low. The Z-SCORE proposed in this project gives a promising 6 Malaysia Society for Computed Tomography & Imaging Technology

7 REAL-TIME MEASUREMENT OF GAS VOIDS IN WAXY CRUDE OIL VIA ECT Prepared by: Assoc. Prof. Ir. Dr. Idris Ismail, Introduction The research work involves the study of the gel formation behavior of a waxy crude oil under different flow rate and temperature conditions using ECT. It is an imaging technique that was developed to study the direct analysis of the internal characteristics of an enclosure. Its basic endeavor is to find the cross-sectional parameters/images of dynamic industrial processes. It is one of the possible techniques to provide quantitative flow used for visualization and flow rate information such as volume void fraction. Visualization techniques and raw data analysis will be used to quantify volume fraction at the measured plane. voids are considerably important for sustainable operations. Objective To investigate the formation of gelled crude under different flow rate and temperature conditions by assessing the distribution and volume of gas voids within the gel formed. Problem Statement In offshore oil exploration, due to prolonged production shutdowns for maintenance or emergency reasons, the crude oil is stationary and the temperature within the pipeline drops significantly (static cooling). In such application, the crude oil contained under quiescent conditions to temperature as low as 5oC. Due to which paraffin precipitate out and form a strong paraffinic gel that cause a complete pipeline plugging where the yield stress and thixotropic behavior are exaggerated. During gel build up the waxy crude undergoes thermal shrinkage where gas voids subsequently appear resulting in supposedly, compressible structure. Therefore, the measurement of gas Gas Voids Volume (%) y = 7E-05x x x R² = y = -7E-05x x x R² = Plane 1 Plane 2 Poly. (Plane 1) Poly. (Plane 2) Temperature ( C) Gas Void Formation in Statically Cooled Waxy Crude Oil INTERNATIONAL WORKSHOP ON COMPUTED TOMOGRAPHY AND INDUSTRIAL IMAGING IWMYCT 2015 Prepared by: Assoc. Prof. Ir. Dr. Idris Ismail, idrisim@petronas.com.my 7 Malaysia Society for Computed Tomography & Imaging Technology 1 June 2015, International Workshop On Computed Tomography and Industrial Imaging (IWMYCT) 2015 was successfully held in Hotel Putra Brasmana, Kuala Perlis, Perlis. IWMYCT was initiated and organized by UniMAP and MYCT to further promote CT technology in both academics and imaging industries. A total of 14 papers was presented by deligates from Vietnam, Indonesia and Malaysia.

8 3rd March 2015, 2nd MyCT Annual General Meeting 4th MyCT Board of Management Meeting 2015 UiTM Shah Alam 24th November2014, 3rd MyCT Board of Management Meeting 2014 Lense MyCT 28-30th November2014, 5th Exposition on Islamic Innovation 2014 (i-inova 2014) 27th to 29th January 2015, Prof Kyung Youn Kim from Jeju National University, visit to Malaysian Nuclear Agency Visit to Imaging Centres at the University of Tokushima and Hiroshima, Japan 8 Malaysia Society for Computed Tomography & Imaging Technology

9 MYCT MEMBER WINS TWO AWARDS AT THE INTERNATIONAL TRANS- TASMAN 3-MINUTE THESIS COMPETITION (3MT) HELD IN AUSTRALIA Prepared by: Johari Yap, 2 OCTOBER 2015 Jaysuman B. Pusppanathan, a member of MyCT received 2 Awards at the International Trans- Tasman 3-Minute Thesis Competition (3MT) held at the University of Queensland, Australia. Awarded as runner On the stage, Jaysuman presented his PhD research in Dual Modality Tomography for Multiphase Flow Imaging under the supervision of Prof. Dr. Hj. Ruzairi Abdul Rahim from Universiti Teknologi Malaysia. The research aims to measure three phase flow by emerging ultrasonic tomography and electrical capacitance tomography. With this success, for the first time in such competition, he had introduced process tomography to the globe. The same topic was presented and awarded as winner at Ritsumeikan University in Japan at the Asia level before competiting in trans-tasman 3MT. The first 3MT was held at UQ in 2008 with 160 RHD students competing. Since 2011 the popularity of the competition has increased and 3MT competitions are now held in over 200 universities across more than 18 countries worldwide. Competitors are given three minutes to give an engaging up, he takes away prize of A$3,000 in the form of a travel research grant as well as a trophy. He also won the People s Choice Award by majority vote enabling him to win A$1,000 in research grant. Three minutes may not seem like much time to explain an 80,000 word PhD thesis that has taken years to research and develop, but that s exactly what is required of PhD candidates competing in the Three Minute Thesis (3MT ) competition. Jaysuman beat 50 other postgraduate contestants from across the globe from China, New Zealand, Japan, H o n g Kong and others who have been selected through rigorous national and dynamic talk on their thesis topic, and highlighting the significance of the thesis topic. The talk is targeted at an educated but non-specialist audience. The competition does not trivialize research but compels students to consolidate their ideas. Springer, one of the world s leading global research, educational and professional publishers is proud to be the principal sponsor of the 2015 Trans-Tasman Three Minute Thesis (3MT) competition. 3 M T competitions in their respective countries. 3MT competition has been organized at the Malaysia level since year 2012 with the increasing participation among IPTA/IPTS. We hope that this success will inspire other researchers to strive excellence especially in the field of tomography. 9 Malaysia Society for Computed Tomography & Imaging Technology

Ultrasound Processing Circuitry for Ultrasonic Tomography

Ultrasound Processing Circuitry for Ultrasonic Tomography 7B Proceedings of the International Conference on Man-Machine Systems (ICoMMS) Ultrasound Processing Circuitry for Ultrasonic Tomography Nor Muzakkir Nor Ayob 1, Mohd Hafiz Fazalul Rahiman 1, Sazali Yaacob

More information

Simulation Study of Bubble Detection Using Dual-Mode Electrical Resistance and Ultrasonic Transmission Tomography for Two-Phase Liquid and Gas

Simulation Study of Bubble Detection Using Dual-Mode Electrical Resistance and Ultrasonic Transmission Tomography for Two-Phase Liquid and Gas Sensors & Transducers 013 by IFSA http://www.sensorsportal.com Simulation Study of Bubble Detection Using Dual-Mode Electrical Resistance and Ultrasonic Transmission Tomography for Two-Phase Liquid and

More information

Hardware Development of Reflection Mode Ultrasonic Tomography System for Monitoring Flaws on Pipeline

Hardware Development of Reflection Mode Ultrasonic Tomography System for Monitoring Flaws on Pipeline Jurnal Teknologi Full paper Hardware Development of Reflection Mode Ultrasonic Tomography System for Monitoring Flaws on Pipeline Norsuhadat Nordin a, Mariani Idroas a*, Zainal Zakaria a, M. Nasir Ibrahim

More information

Design and Modeling of Linear Back Projection (LBP) Algorithm for Field Programmable Gate Array (FPGA)

Design and Modeling of Linear Back Projection (LBP) Algorithm for Field Programmable Gate Array (FPGA) Design and Modeling of Linear Back Projection (LBP) Algorithm for Field Programmable Gate Array (FPGA) Norhidayati Podari 1, a *, Siti Zarina Mohd Muji 1,b, M.Hairol Jabbar 1,c and Ruzairi Abdul Rahim

More information

Charge-Coupled Device Based on Optical Tomography System for monitoring multiphase flow

Charge-Coupled Device Based on Optical Tomography System for monitoring multiphase flow International Journal of Integrated Engineering, Vol. 9 No. 3 (2017) p. 44-48 Charge-Coupled Device Based on Optical Tomography System for monitoring multiphase flow Juliza Jamaludin 1, Ruzairi Abdul Rahim

More information

Jurnal Teknologi. Full Paper. *Corresponding author

Jurnal Teknologi. Full Paper. *Corresponding author Jurnal Teknologi SIMULATION OF ELECTRODE FOR DUAL- MODALITY ELECTRICAL RESISTANCE TOMOGRAPHY AND ULTRASONIC TRANSMISSION TOMOGRAPHY FOR IMAGING TWO-PHASE LIQUID AND GAS Fazlul Rahman Mohd Yunus a, Ruzairi

More information

Jurnal Teknologi SENSITIVITY MAPS RECONSTRUCTION FOR MAGNETIC INDUCTION TOMOGRAPHY MODALITY USING EXPERIMENTAL TECHNIQUE.

Jurnal Teknologi SENSITIVITY MAPS RECONSTRUCTION FOR MAGNETIC INDUCTION TOMOGRAPHY MODALITY USING EXPERIMENTAL TECHNIQUE. Jurnal Teknologi SENSITIVITY MAPS RECONSTRUCTION FOR MAGNETIC INDUCTION TOMOGRAPHY MODALITY USING EXPERIMENTAL TECHNIQUE Zulkarnay Zakaria a*, Hafizi Suki a, Masturah Tunnur Mohamad Talib a, Ibrahim Balkhis

More information

Pre Conference Workshop on Advanced Digital imaging

Pre Conference Workshop on Advanced Digital imaging Pre Conference Workshop on Advanced Digital imaging Uwe Zscherpel, uwez@bam.de BAM Federal Institute for Materials Research and Testing, Division 8.3 Radiological Methods, Berlin, Germany 1 Content: 1.

More information

English, Bahasa Malaysia, Mandarin, Cantonese, Tamil, Japanese (level 2)

English, Bahasa Malaysia, Mandarin, Cantonese, Tamil, Japanese (level 2) Dr. Jaysuman Bin Pusppanathan CURRICULUM VITAE NRIC : 810620-01-5487 Marital Status : Married Address : School of Biomedical Engineering & Health Sciences, Faculty of Engineering, Universiti Teknologi

More information

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY 12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY Rajashekar

More information

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Film Replacement in Radiographic Weld Inspection The New ISO Standard BAM Berlin Film Replacement in Radiographic Weld Inspection The New ISO Standard 17636-2 Uwe Ewert, Uwe Zscherpel, Mirko Jechow Requests and information to: uwez@bam.de 1 Outline - The 3 essential parameters

More information

Guided Wave Travel Time Tomography for Bends

Guided Wave Travel Time Tomography for Bends 18 th World Conference on Non destructive Testing, 16-20 April 2012, Durban, South Africa Guided Wave Travel Time Tomography for Bends Arno VOLKER 1 and Tim van ZON 1 1 TNO, Stieltjes weg 1, 2600 AD, Delft,

More information

STUDY OF TWO-PHASE PIPE FLOW USING THE AXIAL WIRE-MESH SENSOR

STUDY OF TWO-PHASE PIPE FLOW USING THE AXIAL WIRE-MESH SENSOR STUDY OF TWO-PHASE PIPE FLOW USING THE AXIAL WIRE-MESH SENSOR A. Ylönen and J. Hyvärinen LUT School of Energy Systems / Nuclear Engineering Lappeenranta University of Technology (LUT) P.O. Box 20 FI-53851

More information

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations uwe.ewert@bam.de Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations Uwe Ewert and Uwe Zscherpel BAM Federal Institute for

More information

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES Davi F. OLIVEIRA, Edson V. MOREIRA, Aline S. S. SILVA, José M. B. RABELLO, Ricardo T. LOPES, Marcelo S. PEREIRA, Uwe ZSCHERPEL

More information

Experiences of users in Digital Radiography

Experiences of users in Digital Radiography Computed Radiography Products & Applications Experiences of users in Digital Radiography Jimmy Opdekamp May Jimmy 2006Opdekamp Global Product Manager CR Int l Workshop Imaging NDT Chennai, 25-28 April

More information

ADDING VALUE TO YOUR BUSINESS

ADDING VALUE TO YOUR BUSINESS Developed by experts made for tooling Uddeholm AM Corrax ADDING VALUE TO YOUR BUSINESS #1 IN HIGH PERFORMANCE TOOL STEEL With pioneering research and development, innovative thinking and deep commitment,

More information

v tome x m microfocus CT

v tome x m microfocus CT GE Inspection Technologies v tome x m microfocus CT Uniting premium 3D metrology and inspection with quality and speed. gemeasurement.com/ct x plore precision CT line Inspect with precision, power, and

More information

Computed Radiography

Computed Radiography BAM Berlin Computed Radiography --INDE 2007, Kalpakkam, India -- Uwe Zscherpel, Uwe Ewert BAM Berlin, Division VIII.3 Requests Requests and and information information to: to: Dr. Dr. U. U. Zscherpel Zscherpel

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés

More information

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography ECNDT 26 - Poster 17 Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography Khairul Anuar MOHD SALLEH, Ab. Razak HAMZAH and Mohd Ashhar

More information

THE CR SPECIALISTS HD-CR CR 35 NDT

THE CR SPECIALISTS HD-CR CR 35 NDT THE CR SPECIALISTS HD-CR CR 35 NDT COMPUTED RADIOGRAPHY SYSTEMS Digital Intelligence Ready to Change. www.duerr-ndt.com VERSATILE AND DEPENDABLE HIGH-TECH MADE IN GERMANY Highest resolution DÜRR NDT is

More information

NDT-PRO Services expands service offering

NDT-PRO Services expands service offering NDT-PRO Services expands service offering NDT-PRO Services announced the formal release of two advanced NDT methods, Phased Array (including TOFD) and Eddy Current. What are they and where are the used?

More information

Digital Radiology with Photon Counting Detectors

Digital Radiology with Photon Counting Detectors 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Digital Radiology with Photon Counting Detectors More Info at Open Access Database www.ndt.net/?id=16709

More information

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger QUANTITATIVE COMPUTERIZED LAMINOGRAPHY Suzanne Fox Buchele and Hunter Ellinger Scientific Measurement Systems, Inc. 2201 Donley Drive Austin, Texas 78758 INTRODUCTION Industrial computerized-tomography

More information

Slug Flow Loadings on Offshore Pipelines Integrity

Slug Flow Loadings on Offshore Pipelines Integrity Subsea Asia 2016 Slug Flow Loadings on Offshore Pipelines Integrity Associate Professor Loh Wai Lam Centre for Offshore Research & Engineering (CORE) Centre for Offshore Research and Engineering Faculty

More information

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams ECNDT 2006 - We.3.2.3 Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams Bernhard REDMER, Uwe EWERT Federal Institute of Materials Research and Testing (BAM),

More information

UNIVERSITI TEKNOLOGI MARA SUSTAINABLE DESIGN: RATTAN FOR OFFICE GREEN FURNITURE

UNIVERSITI TEKNOLOGI MARA SUSTAINABLE DESIGN: RATTAN FOR OFFICE GREEN FURNITURE UNIVERSITI TEKNOLOGI MARA SUSTAINABLE DESIGN: RATTAN FOR OFFICE GREEN FURNITURE MUHAMMAD MUIZZUDDIN BIN DARUS Design Report submitted in partial fulfilment of the requirements for the degree of Master

More information

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16394 A COMPARATIVE STUDY ON THE PERFORMANCE

More information

Business Models Summary 12/12/2017 1

Business Models Summary 12/12/2017 1 Business Models Summary 12/12/2017 1 Business Models Summary INDEX 1. Business Models development approach 2. Analysis Framework 3. Analysis of Business Models developed 4. Conclusions 5. Future steps

More information

Advanced Digital Radiography for Field NDT

Advanced Digital Radiography for Field NDT International Symposium on Digital Industrial Radiology and Computed Tomography - We.2.3 Advanced Digital Radiography for Field NDT Ron PINCU, Ofra KLEINBERGER-RIEDRICH Vidisco Ltd. 32 Haharoshet Street,

More information

Study of the Effect of Brightness After Penetration of Light from a Lens

Study of the Effect of Brightness After Penetration of Light from a Lens Jurnal Teknologi Full paper Study of the Effect of Brightness After Penetration of Light from a Lens Mohd Fahajumi Jumaah a, Mohd Zikrillah Zawahir a, Fazlul Rahman Mohd Yunus a, Ruzairi Abdul Rahim a*,

More information

THE COMMERCIALISATION OF RESEARCH BY PUBLIC- FUNDED RESEARCH INSTITUTES (PRIs) IN MALAYSIA

THE COMMERCIALISATION OF RESEARCH BY PUBLIC- FUNDED RESEARCH INSTITUTES (PRIs) IN MALAYSIA THE COMMERCIALISATION OF RESEARCH BY PUBLIC- FUNDED RESEARCH INSTITUTES (PRIs) IN MALAYSIA By Ramraini Ali Hassan BBA (Hons), MSc in Entrepreneurship This thesis is presented to the Murdoch University,

More information

Performance evaluation of a photon counting detector for high energy NDT applications

Performance evaluation of a photon counting detector for high energy NDT applications Performance evaluation of a photon counting detector for high energy NDT applications More info about this article: http://www.ndt.net/?id=22842 Abstract Angela Peterzol 1, Pascal Brun 1, Charlotte Eriksson

More information

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS International Workshop SMART MATERIALS, STRUCTURES & NDT in AEROSPACE Conference NDT in Canada 2011 2-4 November 2011, Montreal, Quebec, Canada AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF

More information

Jurnal Teknologi OPTICAL TOMOGRAPHY SYSTEM: APPLICATION OF CHARGE COUPLED DEVICE (CCD) FOR SOLID AND TRANSPARENT OBJECTS DETECTION.

Jurnal Teknologi OPTICAL TOMOGRAPHY SYSTEM: APPLICATION OF CHARGE COUPLED DEVICE (CCD) FOR SOLID AND TRANSPARENT OBJECTS DETECTION. Jurnal Teknologi OPTICAL TOMOGRAPHY SYSTEM: APPLICATION OF CHARGE COUPLED DEVICE (CCD) FOR SOLID AND TRANSPARENT OBJECTS DETECTION Juliza Jamaludin a,d, Ruzairi Abdul Rahim a*, Herlina Abdul Rahim a, Hafiz

More information

Curved arrays for improved horizontal sizing in small pipe welds

Curved arrays for improved horizontal sizing in small pipe welds INSIGHT published by the British Institute of Non-Destructive Testing For more papers of this publication click: www.ndt.net/search/docs.php3?mainsource=39 PHASED ARRAYS DOI: 10.1784/insi.2008.50.5.253

More information

The design of the artworks was based on the artists observation on environmental issues.

The design of the artworks was based on the artists observation on environmental issues. For Immediate Release Green Environment Theme in Artists Masterpieces 2 Outstanding Artists Incorporating Their Observation in Environmental Issues in Creating Masterpieces for MIECO Designer s Choice

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement INTERNATIONAL STANDARD ISO 16809 First edition 2012-11-15 Non-destructive testing Ultrasonic thickness measurement Essais non destructifs Mesurage de l'épaisseur par ultrasons Reference number ISO 2012

More information

RECENT TRENDS IN ADDITIVE MANUFACTURING

RECENT TRENDS IN ADDITIVE MANUFACTURING Proceedings of AEPR 12, 17th European Forum on Rapid Prototyping and Manufacturing Paris, France, 12-14 June 2012 RECENT TRENDS IN ADDITIVE MANUFACTURING Terry Wohlers Wohlers Associates wohlersassociates.com

More information

Application of a NaI(TI) scintillation detector in a portable gamma-ray tomography instrumentation for pipeline profiling to detect CUI

Application of a NaI(TI) scintillation detector in a portable gamma-ray tomography instrumentation for pipeline profiling to detect CUI Application of a NaI(TI) scintillation detector in a portable gamma-ray tomography instrumentation for pipeline profiling to detect CUI Yvette Shaan-Li Susiapan 1, Ruzairi Abd. Rahim 2, Rasif Mohd. Zain

More information

PUC-Rio. Pipeline Engineering

PUC-Rio. Pipeline Engineering PUC-Rio Pipeline Engineering Research and Education (2018) The Campus at Gavea The University Founded in 1941 Excellence in education & research Leadership role in Brazil Four Centers: Center for Human

More information

HPX1-Plus. For Non-Destructive Testing. THE BENCHMARK IN COMPUTED RADIOGRAPHY.

HPX1-Plus. For Non-Destructive Testing.  THE BENCHMARK IN COMPUTED RADIOGRAPHY. HPX1-Plus For Non-Destructive Testing THE BENCHMARK IN COMPUTED RADIOGRAPHY. Introducing the The HPX family of products has earned many of the NDT industry s most prestigious awards. It was no surprise

More information

UNIVERSITI TEKNOLOGI MARA THE PERFORMANCE MEASURES OF SUPPLY CHAIN MANAGEMENT FOR INFRASTRUCTURE PROJECT

UNIVERSITI TEKNOLOGI MARA THE PERFORMANCE MEASURES OF SUPPLY CHAIN MANAGEMENT FOR INFRASTRUCTURE PROJECT UNIVERSITI TEKNOLOGI MARA THE PERFORMANCE MEASURES OF SUPPLY CHAIN MANAGEMENT FOR INFRASTRUCTURE PROJECT MOHAMAD RAZALI B. ABD WAHAB Thesis submitted in fulfillment of the requirements for the degree of

More information

SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011

SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011 SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011 Automated Defect Recognition Software for Radiographic and Magnetic Particle Inspection B. Stephen Wong 1, Xin Wang 2*,

More information

Turning the wheels of your success

Turning the wheels of your success INDUSTRIAL SERVICES Turning the wheels of your success A comprehensive package of integrated services combining traditional certification and inspection with innovative business solutions based on the

More information

MIRA Purpose MIRA Tomographer MIRA MIRA Principle MIRA MIRA shear waves MIRA

MIRA Purpose MIRA Tomographer MIRA MIRA Principle MIRA MIRA shear waves MIRA Purpose The MIRA Tomographer is a state-of-the-art instrument for creating a three-dimensional (3-D) representation (tomogram) of internal defects that may be present in a concrete element. MIRA is based

More information

Title of Innovation: In-Line Inspection for Water Pipelines

Title of Innovation: In-Line Inspection for Water Pipelines Title of Innovation: In-Line Inspection for Water Pipelines Nominee(s) Margaret Hannaford, P.E., Division Manager, Hetch-Hetchy Water and Power Division of the San Francisco Public Utilities Commission

More information

Development of Mould of Rheology Test Sample via CadMould 3D-F Simulation

Development of Mould of Rheology Test Sample via CadMould 3D-F Simulation IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Development of Mould of Rheology Test Sample via CadMould 3D-F Simulation To cite this article: M.H. Othman et al 2017 IOP Conf.

More information

Digital Radiography and its Advantages in Field NDT Inspections Today

Digital Radiography and its Advantages in Field NDT Inspections Today 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Digital Radiography and its Advantages in Field NDT Inspections Today Ron PINCU NDT Division Manager, Vidisco Ltd. 32 Haharoshet

More information

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012 The HOIS recommended practice for in-service computed radiography of pipes WCNDT 2012, Durban, SA. April 2012 Dr Stephen F Burch, ESR Technology, Oxfordshire,UK steve.burch@esrtechnology.com ESR Technology

More information

SYLLABUS. 1. Identification of Subject:

SYLLABUS. 1. Identification of Subject: SYLLABUS Date/ Revision : 30 January 2017/1 Faculty : Life Sciences Approval : Dean, Faculty of Life Sciences SUBJECT : Biophysics 1. Identification of Subject: Name of Subject : Biophysics Code of Subject

More information

Online Optical Tomography System Application of Charge-Coupled Device (CCD) for Object Detection in Crystal Clear Water

Online Optical Tomography System Application of Charge-Coupled Device (CCD) for Object Detection in Crystal Clear Water Online Optical Tomography System Application of Charge-Coupled Device (CCD) for Object Detection in Crystal Clear Water 1,2 1 1 Juliza Jamaludin, Ruzairi Abdul Rahim, Herlina Binti Abdul Rahim, Mohd Hafiz

More information

High Value Manufacturing Catapult

High Value Manufacturing Catapult High Value Manufacturing Catapult Dr Daniel Thompson Senior Technology Officer @ National Composites Centre HVM Catapult Presentation 11 February 2016 UK Manufacturing the Facts The global manufacturing

More information

ASEAN s LEADING LAB EXHIBITION OCTOBER 2017

ASEAN s LEADING LAB EXHIBITION OCTOBER 2017 Malaysia 6 th International Scientific Instrument and Laboratory Equipment Exhibition and Conference ASEAN s LEADING LAB EXHIBITION 10-12 OCTOBER 2017 Level 4, Putra World Trade Centre (PWTC), Kuala Lumpur,

More information

FNCA 2009 WORKSHOP ON HUMAN RESOURCE DEVELOPMENT COUNTRY REPORT MALAYSIA JUNE 2009, FUKUI, JAPAN

FNCA 2009 WORKSHOP ON HUMAN RESOURCE DEVELOPMENT COUNTRY REPORT MALAYSIA JUNE 2009, FUKUI, JAPAN FNCA 2009 WORKSHOP ON HUMAN RESOURCE DEVELOPMENT COUNTRY REPORT MALAYSIA 22 25 JUNE 2009, FUKUI, JAPAN 1. INTRODUCTION 2. PRESENT STATUS OF NATIONAL HRD IN SCIENCE &TECHNOLOGY PROGRAM 3. HRD IN NUCLEAR

More information

Revised zone method R-value calculation for precast concrete. sandwich panels containing metal wythe connectors. Byoung-Jun Lee and Stephen Pessiki

Revised zone method R-value calculation for precast concrete. sandwich panels containing metal wythe connectors. Byoung-Jun Lee and Stephen Pessiki Revised zone method R calculation for precast concrete sandwich panels containing metal wythe connectors Byoung-Jun Lee and Stephen Pessiki Editor s quick points n Metal wythe connectors are used in a

More information

Innovation and Entrepreneurship in Engineering Education. Prof. KC Chan Head Department of Industrial and Systems Engineering

Innovation and Entrepreneurship in Engineering Education. Prof. KC Chan Head Department of Industrial and Systems Engineering Innovation and Entrepreneurship in Engineering Education Prof. KC Chan Head Department of Industrial and Systems Engineering The T.I.E. Innovation drives technology growth Entrepreneurship consummates

More information

ON THE WAY TO DIGITAL RADIOGRAPHY

ON THE WAY TO DIGITAL RADIOGRAPHY The 14 th International Conference of the Slovenian Society for Non-Destructive Testing»Application of Contemporary Non-Destructive Testing in Engineering«September 4-6, 2017, Bernardin, Slovenia More

More information

Digital Profile Radiography Practical uses and limitations

Digital Profile Radiography Practical uses and limitations Digital Profile Radiography Practical uses and limitations Mr. Neil Young Asset Reliability Inspections Bunbury, Australia www.ari.com.au neil.young@ari.com.au Introduction Profile digital radiography

More information

Part 3: Image quality classes

Part 3: Image quality classes INTERNATIONAL STANDARD ISO 19232-3 Second edition 2013-06-15 Non-destructive testing Image quality of radiographs Part 3: Image quality classes Essais non destructifs Qualité d image des radiogrammes Partie

More information

Show. Updates March Kuala Lumpur, Malaysia otcasia.org #otcasia #derrickandsoo

Show. Updates March Kuala Lumpur, Malaysia otcasia.org #otcasia #derrickandsoo Show Updates 20-23 March 2018 Kuala Lumpur, Malaysia 2018.otcasia.org #otcasia #derrickandsoo Conference Highlights 10 15 40+ 300+ 200+ engaging plenaries and panel discussions focused country and special

More information

DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER

DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER 14.03.2016 DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS Bernhard REDMER Digital Technology and Networking Imaging Plates Scanner for Imaging Plates Data Transmission Reporting Computed Radiography

More information

The field deployable digital X-Ray solution for weld inspection in O&G

The field deployable digital X-Ray solution for weld inspection in O&G The field deployable digital X-Ray solution for weld inspection in O&G Imagination at work. Haitham Ibrahim, Hanley Thomas, Steven Wissels 7 th MENDT Conference Bahrain Agenda Field inspection Actual weld

More information

DUAL MODALITY TOMOGRAPHY SYSTEM USING OPTICAL AND ELECTRODYNAMIC SENSORS FOR TOMOGRAPHIC IMAGING SOLID FLOW

DUAL MODALITY TOMOGRAPHY SYSTEM USING OPTICAL AND ELECTRODYNAMIC SENSORS FOR TOMOGRAPHIC IMAGING SOLID FLOW DUAL MODALITY TOMOGRAPHY SYSTEM USING OPTICAL AND ELECTRODYNAMIC SENSORS FOR TOMOGRAPHIC IMAGING SOLID FLOW M. F. Rahmat 1, S. Ibrahim 1, M. M. Elmajri 1, N. F. Mohammed 1, M.D Isa 2 1 Control and Instrumentation

More information

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices Moving from film to digital: A study of digital x-ray benefits, challenges and best practices H.U. Pöhler 1 and N. D Ademo 2 DÜRR NDT GmbH & Co. KG, Höpfigheimer Straße 22, Bietigheim-Bissingen, 74321,

More information

MODELLING OF A MAGNETIC ADHESION ROBOT FOR NDT INSPECTION OF LARGE METAL STRUCTURES

MODELLING OF A MAGNETIC ADHESION ROBOT FOR NDT INSPECTION OF LARGE METAL STRUCTURES MODELLING OF A MAGNETIC ADHESION ROBOT FOR NDT INSPECTION OF LARGE METAL STRUCTURES G. SHIRKOOHI and Z. ZHAO School of Engineering, London South Bank University, 103 Borough Road, London SE1 0AA United

More information

Examination of Pipe Welds by Image Plate Based Computed Radiography System

Examination of Pipe Welds by Image Plate Based Computed Radiography System Examination of Pipe Welds by Image Plate Based Computed Radiography System Sanjoy Das, M.S.Rana, Benny Sebastian, D. Mukherjee and K.K. Abdulla Atomic Fuels Division Bhabha Atomic Research Centre Mumbai

More information

New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines

New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines A. Barbian 1, M. Beller 1, F. Niese 2, N. Thielager 1, H. Willems 1 1 NDT Systems & Services

More information

Knowledge Requirements. Protective Coatings Applicator Abrasive Blast Cleaning Operator Spray Painting Operator. trainthepainter.

Knowledge Requirements. Protective Coatings Applicator Abrasive Blast Cleaning Operator Spray Painting Operator. trainthepainter. Knowledge Requirements Protective Coatings Applicator Abrasive Blast Cleaning Operator Spray Painting Operator trainthepainter.com Knowledge Requirements The Knowledge Requirements the protective coatings

More information

ULTRASONIC DEFECT DETECTION IN BILLET USING TIME- OF-FLIGHT OF BOTTOM ECHO

ULTRASONIC DEFECT DETECTION IN BILLET USING TIME- OF-FLIGHT OF BOTTOM ECHO ULTRASONIC DEFECT DETECTION IN BILLET USING TIME- OF-FLIGHT OF BOTTOM ECHO Ryusuke Miyamoto Graduate School of Systems and Information Engineering, University of Tsukuba, Tsukuba, Ibaraki 305-8573 Japan

More information

SMALL-SIZE BETATRON FOR THE ENERGY 2.5 MEV FOR FIELD INSPECTION

SMALL-SIZE BETATRON FOR THE ENERGY 2.5 MEV FOR FIELD INSPECTION SMALL-SIZE BETATRON FOR THE ENERGY 2.5 MEV FOR FIELD INSPECTION V. G. Volkov, Yu. D. Zrelov, V. A. Kasyanov, A. A. Filimonov, V. L. Chakhlov, M. M. Shtein State educational institution of higher professional

More information

A TRUSTING RELATIONSHIP

A TRUSTING RELATIONSHIP A TRUSTING RELATIONSHIP Dear Reader, 2015 has turned into a very challenging year for both mining and steel industries. Worldwide economies have been hit by volatility of capital markets, devaluation of

More information

High Frequency Acoustic Signal Analysis for Internal Surface Pipe Roughness Classification

High Frequency Acoustic Signal Analysis for Internal Surface Pipe Roughness Classification High Frequency Acoustic Signal Analysis for Internal Surface Pipe Roughness Classification Z. M. Hafizi, C.K.E. Nizwan, M.F.A. Reza & M.A.A. Johari Faculty of Mechanical Engineering, Universiti Malaysia

More information

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography 7 th European-American Workshop on Reliability of NDE Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography Uwe EWERT, Uwe ZSCHERPEL, Justus VOGEL, Fangzhou ZHANG

More information

A Longer Life. MME Group Specialties. NDT Training Courses Cathodic Protection (CP) MGPS (ICAF) Harbinger Boarding Equipment

A Longer Life. MME Group Specialties. NDT Training Courses Cathodic Protection (CP) MGPS (ICAF) Harbinger Boarding Equipment A Longer Life Mankind creates increasingly large objects. Our society can no longer do without bridges, ships, drilling rigs, refineries and other complex structures. Without due attention to quality and

More information

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr lndustrial Computed Radiography with storage phosphor imaging plates results of a classification of the system Dürr HD-CR 35 NDT scanner with blue HD- IP Plus imaging plates (HD-IP + ) BAM reference BAM

More information

BF-X2. In-line 3D automated X-ray inspection system for Semiconductor, Power module inspection

BF-X2. In-line 3D automated X-ray inspection system for Semiconductor, Power module inspection In-line automated X-ray inspection system for Semiconductor, Power module inspection BF-X2 Visualize the inner structure with innovative automated inspection In-line automated X-ray inspection system for

More information

Introduction To NDT. BY: Omid HEIDARY

Introduction To NDT. BY: Omid HEIDARY Introduction To NDT BY: Omid HEIDARY NDT Methods Penetrant Testing Magnetic Particle Testing Eddy Current Testing Ultrasonic Testing Radiographic Testing Acoustic Emission Infrared Testing Visual Testing

More information

MULTIPLE CLASSIFIERS FOR ELECTRONIC NOSE DATA

MULTIPLE CLASSIFIERS FOR ELECTRONIC NOSE DATA MULTIPLE CLASSIFIERS FOR ELECTRONIC NOSE DATA M. Pardo, G. Sberveglieri INFM and University of Brescia Gas Sensor Lab, Dept. of Chemistry and Physics for Materials Via Valotti 9-25133 Brescia Italy D.

More information

PEOPLE PROCESS EQUIPMENT TECHNOLOGY VALUE. Cased-Hole Services Optimize Your Well Production

PEOPLE PROCESS EQUIPMENT TECHNOLOGY VALUE. Cased-Hole Services Optimize Your Well Production PEOPLE PROCESS EQUIPMENT TECHNOLOGY VALUE Cased-Hole Services Optimize Your Well Production Optimize Your Well Production Allied-Horizontal s complete portfolio of reservoir evaluation and completion services

More information

Programme Learning Outcomes Assessment and Continuous Quality Improvement in Faculty of Mechanical and Manufacturing, UTHM

Programme Learning Outcomes Assessment and Continuous Quality Improvement in Faculty of Mechanical and Manufacturing, UTHM IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Programme Learning Outcomes Assessment and Continuous Quality Improvement in Faculty of Mechanical and Manufacturing, UTHM To

More information

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology Uwe EWERT, Uwe ZSCHERPEL, Mirko

More information

Thermodynamic Modelling of Subsea Heat Exchangers

Thermodynamic Modelling of Subsea Heat Exchangers Thermodynamic Modelling of Subsea Heat Exchangers Kimberley Chieng Eric May, Zachary Aman School of Mechanical and Chemical Engineering Andrew Lee Steere CEED Client: Woodside Energy Limited Abstract The

More information

DACON INSPECTION SERVICES. Computed RADIOGRAPHY

DACON INSPECTION SERVICES. Computed RADIOGRAPHY CR Computed RADIOGRAPHY Who we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400 personnel including more than 300 inspectors

More information

CONFERENCE PROCEEDING. International Conference of Management, Business & Social Sciences Impact (ICMBSSI 2018) USA PASSION DEVELOPMENT

CONFERENCE PROCEEDING. International Conference of Management, Business & Social Sciences Impact (ICMBSSI 2018) USA PASSION DEVELOPMENT USA PASSION DEVELOPMENT CONFERENCE PROCEEDING International Conference of Management, Business & Social Sciences Impact (ICMBSSI 2018) 0 0 International Conference of Management, Business & Social Sciences

More information

Australian Journal of Basic and Applied Sciences

Australian Journal of Basic and Applied Sciences AENSI Journals Australian Journal of Basic and Applied Sciences ISSN:1991-8178 Journal home page: www.ajbasweb.com Context-Based Image Segmentation of Radiography 1 W. Al-Hameed, 2 P.D. Picton, 3 Y. Mayali

More information

ACEEE Int. J. on Electrical and Power Engineering, Vol. 03, No. 02, May 2012

ACEEE Int. J. on Electrical and Power Engineering, Vol. 03, No. 02, May 2012 Effect of Glittering and Reflective Objects of Different Colors to the Output Voltage-Distance Characteristics of Sharp GP2D120 IR M.R. Yaacob 1, N.S.N. Anwar 1 and A.M. Kassim 1 1 Faculty of Electrical

More information

High Energy Digital Radiography & 3D-CT for Industrial Systems

High Energy Digital Radiography & 3D-CT for Industrial Systems DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France High Energy Digital Radiography & 3D-CT for Industrial Systems Non-Destructive

More information

By: Derek Watson and Lee Robins, Tracerco, UK

By: Derek Watson and Lee Robins, Tracerco, UK TRACERCO DISCOVERY SUBSEA CT (COMPUTED TOMOGRAPHY) HELPS TO OPTIMISE YOUR OPERATIONAL PIGGING CAMPAIGN AND VERIFY ILI RESULTS: TECHNOLOGY FOR PIPELINE INTEGRITY AND FLOW ASSURANCE VISUALISATION By: Derek

More information

LEADING DIGITAL TRANSFORMATION AND INNOVATION. Program by Hasso Plattner Institute and the Stanford Center for Professional Development

LEADING DIGITAL TRANSFORMATION AND INNOVATION. Program by Hasso Plattner Institute and the Stanford Center for Professional Development LEADING DIGITAL TRANSFORMATION AND INNOVATION Program by Hasso Plattner Institute and the Stanford Center for Professional Development GREETING Digital Transformation: the key challenge for companies and

More information

ASSESSING USER PERCEIVED SERVICE QUALITY OF DIGITAL LIBRARY

ASSESSING USER PERCEIVED SERVICE QUALITY OF DIGITAL LIBRARY ASSESSING USER PERCEIVED SERVICE QUALITY OF DIGITAL LIBRARY Wan Abdul Rahim Wan Mohd Isa and Saman Omed Abdullah Faculty of Computer and Mathematical Sciences, Universiti Teknologi MARA, Shah Alam, Selangor,

More information

SPOOLBASE & MULTIJOINT SERVICES

SPOOLBASE & MULTIJOINT SERVICES SPOOLBASE & MULTIJOINT SERVICES PIPELINE FABRICATION COMPANY PROFILE Pipeline Technique is a world leading provider of solutions to the oil and gas industry for the most demanding challenges in Welding,

More information

Nondestructive Testing of Drilled Shaft Foundations

Nondestructive Testing of Drilled Shaft Foundations Nondestructive Testing of Drilled Shaft Foundations Magued Iskander, PhD, PE, F.ASCE Why NDT for Integrity? Drilled shafts cannot be visually inspected after construction Load tests are expensive - only

More information

Research & Development

Research & Development Research & Development This global network is a fundamental component in Tenaris s approach to serving the customer. Innovation that fuels growth At Tenaris, we aim to raise the quality and range of our

More information

Enhanced Resonant Inspection Using Component Weight Compensation. Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241

Enhanced Resonant Inspection Using Component Weight Compensation. Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241 Enhanced Resonant Inspection Using Component Weight Compensation Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241 ABSTRACT Resonant Inspection is commonly used for quality assurance

More information

UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY

UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY A DISCUSSION REGARDING THE CURRENT STATE OF THE TECHNOLOGY AND THE REASONS BEHIND THE SLOW TRANSITION FROM FILM

More information

RCS classification on ground moving target using lte passive bistatic radar

RCS classification on ground moving target using lte passive bistatic radar Journal of Scientific Research and Development 3 (2): 57-61, 2016 Available online at www.jsrad.org ISSN 1115-7569 2016 JSRAD RCS classification on ground moving target using lte passive bistatic radar

More information

Sensor Systems and NDE Technology Section January 2017

Sensor Systems and NDE Technology Section January 2017 Sensor Systems and NDE Technology Section January 2017 Sensor System and NDE Technology Section Staff and Project Breakdown Total staff 17 16 hold technical degrees (EE, ME, and physics) 5 with Ph.D. Projects

More information