Nicolet Almega XR. High Performance Micro and Macro Dispersive Raman Analysis Systems
|
|
- Alaina French
- 6 years ago
- Views:
Transcription
1 m o l e c u l a r s p e c t r o s c o p y Nicolet Almega XR High Performance Micro and Macro Dispersive Raman Analysis Systems Materials Research Identification/Verification Characterization Failure Analysis High-Throughput Screening Mapping in 3 Dimensions Part of Thermo Fisher Scientific
2 C UTTING-EDGE S OLUTIONS
3 Thermo Scientific Nicolet Almega XR Dispersive Raman Powerful, cutting-edge solutions for Raman High-performance Raman is coming of age as an analytical technique, and the Thermo Scientific Nicolet Almega XR system captures the full potential of this technique by offering a powerful research and development tool. Combining Raman performance with extremely flexible configurations and incredible ease of use, the system provides a wide range of solutions to analytical problems related to molecular structure. Wide-Ranging Applications and Sampling Flexibility Pharmaceuticals Semiconductor Devices Forensics Gems & Minerals Polymers Protective Coatings S AMPLING V ERSATILITY
4 P RODUCTIVE The innovative technology behind the Nicolet Almega XR dispersive Raman spectrometer lets you get the answers you need faster and with greater ease. Automated features engineered throughout the system mean your time is spent getting accurate results. Versatile sampling options designed to handle a wide variety of samples further increase productivity and lab efficiency. Automated Saves You Time and Makes Analysis Less Subjective Excitation laser and Rayleigh rejection filter switching Patented automatic laser alignment Automatic grating switching Automatic software configuration of instruments settings corresponds to laser and resolution selections Automating sampling experiments saves time and makes profiling larger areas easy Intuitive Operation and Short Learning Curve Simple software instrument controls Laser-safety interlocks for simple and safe operation Fast Real time feedback for manipulating instrument settings Switch between lasers as well as micro and macro sampling in seconds without any tools Autosampling options Complete Solutions Get All the Equipment and Support from One Source Everything integrated in one software and hardware package No laborious manual alignment or calibration routines Dependable Dependable and objective results with on board automated calibration Depend on safety with the full class 1 laser safe configuration Dependable operation with field proven design US. Patent 6,661,509, US Patent 7,233,870, other patents pending Advanced Sampling Options Maximize the power of the Nicolet Almega XR system with specialized sampling options for your specific analysis needs. Well-plate Autosampling Liquid Autosampling Powder Autosampling Capillary Tube Autosampling Remote Sampling
5 P OWERFUL The powerful set of tools provided by the Nicolet Almega XR system provides you with a wide selection of methods to interrogate your samples, and to generate the best possible data along with the software tools you will need to reveal all the information the data contains. The Nicolet Almega XR system gives you confidence that your lab is getting everything that the Raman technique has to offer. Powerful Software Toolkit Completely integrated package Total instrument control Data collection and advanced data manipulation tools Advanced library searching algorithms to give you better matches Extensive quantitative tools including multivariate and principle component-based methods for sophisticated quant Advanced chemical profiling option to view your results from multiple perspectives single wavenumber images peak ratio images quantitative analysis images Powerful Performance Simple custom report generation for displaying your results Data audit trails for regulation compliance Online help at every step to guide you Superior spatial resolution Broad spectral range Extremely low noise Superior fluorescence rejection Excellent sensitivity even with small samples Fast and accurate laser switching and alignment High throughput no fiber-coupled optics Powerful Hardware High-brightness lasers deliver more energy to your samples High-quality, visual viewing optics distinguish the small details of your sample TE-cooled, high-sensitivity, Si CCD for the best Raman detection Seamless switching between two excitation lasers Infinity-corrected optics Gratings optimized for each laser True confocal microscope optics for depth profiling Automatic alignment with all lasers so you always know where you are sampling without exposing your eyes to dangerous laser light Powerful Sampling Options Excellent small sample capabilities Nondestructive depth profiling Mapping in 3 dimensions with complete spectral information no sacrifices Mosaic mapping of sample areas larger than the field of view Polarization studies Automated white-light background correction High throughput auto-sampling Orientation independent crystalline studies using the depolarization kit Rapid sample interrogation with multiple excitation lasers Remote sampling
6
7 Versatile Configurations Open Architecture Fully Class-I Laser Safe Supports robotic sample delivery Comprehensive software tools Large selection of libraries Large selection of excitation lasers Large selection of visual viewing options transmission and reflection bright field and dark field polarized light Large selection of stages motorized stages heated and subambient sampling stages wafer stages Micro and macro sampling without compromises Autosampling well-plate autosampling options NMR tube and test tube autosampling Fully upgradeable to add capabilities as you need them and make sure you always have access to the technology you might need Every feature described is not included in every configuration. Many features are provided as options allowing you to configure a system to meet your specific requirements at the best possible price. Consult your sales representative for more information.
8 Laboratory Solutions Backed by Worldwide Service and Support The Nicolet Almega XR dispersive Raman system is backed up by the support staff of the largest analytical instrument company in the world, Thermo Fisher Scientific. Service and support is available almost everywhere in the world. We have more Raman-trained field service engineers and Raman-trained applications people to support you than any other company. Meeting all of your support needs is our highest priority. Comprehensive Support for Your Raman Needs: On-site visits from factory-trained field service engineers Technical phone support Internet-based technical support Performance maintenance programs Classroom and on-site training programs Contract method and application development programs In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Africa analyze.emea@thermo.com Australia analyze.au@thermo.com Austria analyze.at@thermo.com Belgium analyze.be@thermo.com Canada analyze.ca@thermo.com China analyze.cn@thermo.com Denmark analyze.dk@thermo.com Europe-Other analyze.emea@thermo.com France analyze.fr@thermo.com Germany analyze.de@thermo.com India analyze.in@thermo.com Italy analyze.it@thermo.com Japan analyze.jp@thermo.com Latin America analyze.la@thermo.com Middle East analyze.emea@thermo.com Netherlands analyze.nl@thermo.com South Africa analyze.sa@thermo.com Spain analyze.es@thermo.com Sweden / Norway / Finland analyze.se@thermo.com Switzerland analyze.ch@thermo.com UK analyze.uk@thermo.com USA analyze.us@thermo.com Thermo Electron Scientific Instruments LLC, Madison, WI USA is ISO Certified. If the Class I option is not selected then the system is a Class IIIb laser product Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR50446_E 12/07M
Nicolet Continuμm Infrared Microscope
m o l e c u l a r s p e c t r o s c o p y Nicolet Continuμm Infrared Microscope Infrared Microscopy Excellence Crystal-clear Visible Microscopy Superior Purity Infrared Spectroscopy New Dimensions in Imaging
More informationThermo Scientific Nicolet in10 FT-IR Microscope
m o l e c u l a r s p e c t r o s c o p y Thermo Scientific Nicolet in10 FT-IR Microscope Infrared Microscopy with Confidence intuitive innovative integrated Part of Thermo Fisher Scientific Thermo Scientific
More informationNicolet Evolution 500. UV-Visible Spectrophotometer
m o l e c u l a r s p e c t r o s c o p y Nicolet Evolution 500 UV-Visible Spectrophotometer Analyze Detect Measure Control Nicolet Evolution 500 UV-Vis High-Performance, Exceptional Value The Nicolet
More informationThermo Scientific SPECTRONIC 200 Education
molecular spectroscopy Thermo Scientific SPECTRONIC 200 Education Part of Thermo Fisher Scientific Designed for the Teaching Laboratory Classroom Friendly Sample Compartment Whether you measure in 10 mm
More informationThermo Scientific SPECTRONIC 200
molecular spectroscopy Thermo Scientific SPECTRONIC 200 Part of Thermo Fisher Scientific The New Standard for Routine Measurements Robust, Multifunction Sample Compartment Whether you measure in 10 mm
More informationThermo Scientific DXRxi Raman Imaging Microscope. Accelerate your work Visualize your answers
Thermo Scientific DXRxi Raman Imaging Microscope Accelerate your work Visualize your answers Raman imaging evolved Walk-up-and-run ease of use Visually driven image acquisition A microscopy-first approach
More informationThermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument
Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer The perfect teaching instrument Designed for the Teaching Laboratory Thermo Scientific SPECTRONIC spectrophotometers have served as core analytical
More informationThermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect tool. for routine measurements
Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer The perfect tool for routine measurements The Standard for Routine Measurements Thermo Scientific SPECTRONIC spectrophotometers have served as
More informationFT-IR.
FT-IR varian, inc. 610/620-IR ft-ir MICROSCOPY AND IMAGING SoLUTIONS www.varianinc.com VARIAN, INC. Setting the Standard Again When Only the Best Will Do The world leader in molecular spectroscopy innovation
More informationA RELIABLE FOUNDATION FOR IC ANALYSIS THERMO SCIENTIFIC DIONEX AQUION IC SYSTEM
A RELIABLE FOUNDATION FOR IC ANALYSIS THERMO SCIENTIFIC DIONEX AQUION IC SYSTEM INTRODUCE YOUR LAB TO IC ANALYSIS WITH A SIMPLIFIED, EASY-TO-USE SYSTEM The Thermo Scientific Dionex Aquion Ion Chromatography
More informationSpotlight 150 and 200 FT-IR Microscopy Systems
S P E C I F I C A T I O N S Spotlight 150 and 200 FT-IR Microscopy Systems FT-IR Microscopy Spotlight 200 with Frontier FT-IR Spectrometer Introduction PerkinElmer Spotlight FT-IR Microscopy Systems are
More informationThermo Scientific Nicolet in10 FT-IR Microscope. Infrared microscopy. with confidence. intuitive innovative integrated
Thermo Scientific Nicolet in10 FT-IR Microscope Infrared microscopy with confidence intuitive innovative integrated Thermo Scientific Nicolet in10 FT-IR Microscope The Infrared Microscope that Delivers
More informationSolutions for Solar Cell and Module Testing
Solutions for Solar Cell and Module Testing Agilent 663XB Power Supplies Connected in Anti-Series to Achieve Four-Quadrant Operation for Solar Cell and Module Testing Application Note Overview To fully
More informationProcess Control Calibration Made Easy with Agilent U1401A
Process Control Calibration Made Easy with Agilent U1401A Application Note This application note explains how the Agilent U1401A with simultaneous source and measure functions eases technicians calibration
More informationSOURCE MEASURE UNITS. Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money
SOURCE MEASURE UNITS Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money Do you use a power supply or digital multimeter? How about an electronic load,
More informationSpectrum 400. FT-IR and FT-NIR Spectrometer. There is only one answer.
Spectrum 400 FT-IR and FT-NIR Spectrometer There is only one answer. The latest innovation in PerkinElmer s long history of IR technology leadership For over 60 years, PerkinElmer has been the world leader
More informationThermo Scientific ARL ADVANT'X Series IntelliPower Technology
e l e m e n t a l a n a l y s i s Thermo Scientific ARL ADVANT'X Series IntelliPower Technology Sequential X-Ray Fluorescence Spectrometers Geology/Environment Petrochemicals/Polymers Raw materials/mining
More informationAutomated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE
Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software Introduction For undergraduate students in colleges and universities, frequency response testing
More informationSENTERRA II. Innovation with Integrity. The Next Level of Compact Raman Microscopy. Raman
SENTERRA II The Next Level of Compact Raman Microscopy Innovation with Integrity Raman Research-grade spectroscopic performance Next Level Compact Raman Microscopy The SENTERRA II defines a new level of
More informationTekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet
Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet TCA-SMA -to-sma DC to 18 GHz (instrument dependent) TCA-292MM -to-2.92 mm DC to 25 GHz (instrument dependent) SMA compatible TCA-292D -to-2.92
More informationMEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs
MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs Application Note Recently, various devices using MEMS technology such as pressure sensors, accelerometers,
More informationIntegrate, validate, and implement
Integrate, validate, and implement Human Identification Professional Services As the world leader in human identification, Thermo Fisher Scientific continues to develop and deliver technologies, services,
More informationPower Measurement and Analysis Software
Power Measurement and Analysis Software TPS2PWR1 Data Sheet Features & Benefits Improve Efficiency of Power Designs with Switching-loss Measurements including Turn-on, Turn-off, and Conduction Losses Reduce
More informationS540 Power Semiconductor Test System Datasheet
S540 Power Semiconductor Test System Datasheet Key Features Automatically perform all wafer-level parametric tests on up to 48 pins, including high voltage breakdown, capacitance, and low voltage measurements,
More informationPhE102-VASE. PHE102 Variable Angle Spectroscopic Ellipsometer. Angstrom Advanced Inc. Angstrom Advanced. Angstrom Advanced
Angstrom Advanced PhE102-VASE PHE102 Variable Angle Spectroscopic Ellipsometer Angstrom Advanced Instruments for Thin Film and Semiconductor Applications sales@angstromadvanced.com www.angstromadvanced.com
More informationSENTERRA II. Innovation with Integrity. The Next Level of Compact Raman Microscopy. Raman
SENTERRA II The Next Level of Compact Raman Microscopy Innovation with Integrity Raman Next Level Compact Raman Microscopy The SENTERRA II defines a new level of spectroscopic performance and user friendliness
More informationAgilent N8480 Series Thermocouple Power Sensors. Technical Overview
Agilent N8480 Series Thermocouple Power Sensors Technical Overview Introduction The new N8480 Series power sensors replace and surpass the legacy 8480 Series power sensors (excluding the D-model power
More informationS540 Power Semiconductor Test System Datasheet
S540 Power Semiconductor Test System Key Features Automatically perform all wafer-level parametric tests on up to 48 pins, including high voltage breakdown, capacitance, and low voltage measurements, in
More informationDual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE
Dual-FL World's Fastest Fluorometer Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE 100 Times Faster Data Collection The only simultaneous absorbance and fluorescence system available
More informationAgilent Cary 610/620 FTIR microscopes and imaging systems RESOLUTION FOR EVERY APPLICATION
Agilent Cary 610/620 FTIR microscopes and imaging systems RESOLUTION FOR EVERY APPLICATION AGILENT CARY 610/620 FTIR MICROSCOPES ADVANCING FTIR MICROSCOPY AND IMAGING Agilent s 610/620 FTIR microscopes
More informationHigh-impedance Buffer Amplifier System
High-impedance Buffer Amplifier System TCA-1MEG Data Sheet Features & Benefits Bandwidth - DC to 500 MHz Input Impedance - 1 MΩ /10pF Bandwidth Limiting - Full/100 MHz/20 MHz Input Coupling - DC/AC/GND
More informationDifferential Probes P6248 P6247 P6246 Datasheet
Differential Probes P6248 P6247 P6246 Datasheet P6247 key performance specifications 1.0 GHz bandwidth (guaranteed) P6246 key performance specifications 400 MHz bandwidth (guaranteed) Key features Low
More informationThe only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog
The only simultaneous absorbance and fluorescence system for water quality analysis! Aqualog CDOM measurements made easy. The only simultaneous absorbance and fluorescence system for water quality analysis!
More informationAdd CLUE to your SEM. High-efficiency CL signal-collection. Designed for your SEM and application. Maintains original SEM functionality
Add CLUE to your SEM Designed for your SEM and application The CLUE family offers dedicated CL systems for imaging and spectroscopic analysis suitable for most SEMs. In addition, when combined with other
More informationio n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V
High-voltage Differential Probes P5200 P5205 P5210 Data Sheet P5205 Features & Benefits Bandwidths up to 100 MHz Up to 5,600 V Differential (DC + pk AC) Up to 2,200 V Common (RMS) Overrange Indicator Safety
More informationHigh-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A
High-voltage Differential Probes TMDP0200 - THDP0200 - THDP0100 - P5200A - P5202A - P5205A - P5210A BNC interface (P5200A probes) TekVPI interface (TMDP and THDP Series probes) TekProbe interface (P5202A,
More informationCreating the world technology leader in surface solutions under one roof
Creating the world technology leader in surface solutions under one roof We are the world technology leader in the growing surface solutions market. Combining the complementary strengths of Oerlikon Balzers
More informationProgrammable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet
Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet Applications University education and research UWB signal source Semiconductor characterization Laser driver The PSPL10000 Series
More informationIf I Could... Imagine Perfect Vision
If I Could... Imagine Perfect Vision With the right oscilloscope you can create better designs, faster. You can characterize circuit performance with greater precision and confidence. You can verify system
More informationMultipurpose Lab Station by Agilent Technologies
Multipurpose Lab Station by Agilent Technologies The Agilent Multipurpose Lab Station is an integrated system comprised of a: 1 2 3 4 5 6 7 8 Mixed signal oscilloscope (MSO) or digital signal oscilloscope
More informationPassive Voltage Probes
Passive Voltage Probes TPP1000 TPP0500 TPP0502 Datasheet Connectivity Integrated Oscilloscope and Probe Measurement System provides Intelligent Communication that Automatically Scales and Adjusts Units
More informationAqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE
Aqualog Water Quality Measurements Made Easy ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING Water
More informationKeysight Technologies Making Current-Voltage Measurement Using SMU
Keysight Technologies Making Current-Voltage Measurement Using SMU Keysight B2901A/02A/11A/12A Precision Source/Measure Unit Demonstration Guide Introduction The Keysight Technologies, Inc. B2901A/02A/11A/12A
More informationT A I N S T R U M E N T S
TA INSTRUMENTS TA HISTORY OF INNOVATION 1962-900 THERMAL ANALYZER FIRST COMMERCIAL DSC 1968 - PRESSURE DSC 1976 - FIRST COMMERCIAL DMA TA Instruments history of meeting customer needs for high technology
More informationVerifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE
Verifying Power Supply Sequencing with an 8-Channel Oscilloscope Introduction In systems that rely on multiple power rails, power-on sequencing and power-off sequencing can be critical. If the power supplies
More information1.5 GHz Active Probe TAP1500 Datasheet
1.5 GHz Active Probe TAP1500 Datasheet Easy to use Connects directly to oscilloscopes with the TekVPI probe interface Provides automatic units scaling and readout on the oscilloscope display Easy access
More informationKeysight Technologies Enhance EMC Testing with Digital IF. Application Note
Keysight Technologies Enhance EMC Testing with Digital IF Application Note Introduction With today s accelerating business environment and development cycles, EMC measurement facilities that offer rapid
More informationKickStart Instrument Control Software Datasheet
KickStart Instrument Control Software Datasheet Key Features Built-in I-V characterizer, datalogger, and precision DC power applications Optional high resistivity measurement application that complies
More information30 A AC/DC Current Probe TCP0030A Datasheet
30 A AC/DC Current Probe TCP0030A Datasheet Split-core construction allows easy circuit connection High accuracy with typically less than 1% DC gain error Low noise and DC drift 3rd party safety certification
More informationN2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes
N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes Data Sheet Oscilloscope users often need to make floating measurements where neither point of the measurement is at earth
More informationHigh-voltage Differential Probes
High-voltage Differential Probes P5200 P5205 P5210 Data Sheet Features & Benefits Bandwidths up to 100 MHz Up to 5,600 V Differential (DC + pk AC) Up to 2,200 V Common (RMS) Overrange Indicator Safety
More informationPatternPro Error Detector PED3200 and PED4000 Series Datasheet
PatternPro Error Detector PED3200 and PED4000 Series Datasheet Applications 25 Gb/s testing for 100G Ethernet 32 Gb/s DPQPSK testing Semiconductor and component testing Design validation and production
More informationLC/MS/MS. Page Header. triple quadrupole mass spectrometer.
LC/MS/MS VARIAN, INC. 320-MS Page Header triple quadrupole mass spectrometer www.varianinc.com VARIAN, INC. 320-MS Unsurpassed commitment to innovation Varian, Inc. is an innovator and leader in mass spectrometry
More informationTecan Group. Corporate Update CONFERENCE CALL JANUARY 15, 2019
Tecan Group Corporate Update CONFERENCE CALL JANUARY 15, 2019 Speakers Dr Lukas Braunschweiler Chairman Dr David Martyr CEO Dr Achim von Leoprechting EVP 2 CEO Succession Tecan just finished another very
More informationFT-IR IMAGING THAT'S CLEARLY MEASURABLY AMAZING. Spotlight 400 FT-IR and 400N FT-NIR Imaging Systems
FT-IR IMAGING THAT'S CLEARLY MEASURABLY AMAZING Spotlight 400 FT-IR and 400N FT-NIR Imaging Systems YOUR CHALLENGES COME IN ALL SHAPES AND SIZES ONE SYSTEM CAN HANDLE THEM ALL It s been called the most
More informationAC/DC Current Probe TCP0150 Datasheet
AC/DC Current Probe TCP0150 Datasheet Low noise and DC drift Provides automatic units scaling and readout on the oscilloscope's display Remote GPIB/USB probe control through the oscilloscope Split-core
More informationUsing the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE
Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements Characterizing a device, material, or process electrically often requires performing
More informationAqualog. Water Quality Measurements Made Easy FLUORESCENCE
Aqualog Water Quality Measurements Made Easy FLUORESCENCE Water quality measurements made easy The only simultaneous absorbance and fluorescence system for water quality analysis! The new Aqualog is the
More informationDiscovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms
Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms Introduction Today, during the designing of electronic components and circuits for computers, peripherals, and consumer
More informationSophisticated Power Loss Analysis Using A Digital Phosphor Oscilloscope
Sophisticated Power Loss Analysis Using A Digital Phosphor Oscilloscope Quickly Locate Power Dissipation in Switching Power Supplies With demand for power driving architectural changes to switching power
More informationAgilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide
Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz Configuration Guide Ordering Guide The following steps will guide you through configuring your 4294A. Standard Furnished Item CD-ROM Manual
More informationSoldering a P7500 to a Nexus DDR Component Interposer
Soldering a P7500 to a Nexus DDR Component Interposer Introduction This document shows an example of how to solder P7500 tips to the oscilloscope version of a Nexus DDR Component Interposer board. The
More informationEthernet Transmitter Test Application Software TekExpress 10GBASE-T and NBASE-T Datasheet
Ethernet Transmitter Test Application Software TekExpress 10GBASE-T and NBASE-T Datasheet Product description Based on the TekExpress test automation framework, the Ethernet Transmitter Test Application
More informationAqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN
Aqualog CDOM Measurements Made Easy ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING CDOM measurements
More informationPassive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet
Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet P5150 DC to 500 MHz 2500 V Peak, 1000 V RMS CAT II 50 X Floatable up to 600 V RMS CAT II or 300 V RMS CAT III For TPS2000 and THS3000
More informationIn-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging
In-Vivo IMAGING SYSTEMS A complete line of high resolution optical & X-ray systems for pre-clinical imaging In-Vivo Imaging Systems Carestream is a strong, successful, multi-billion dollar, international
More informationApproachable Raman Solutions The Shortest Path from Problem to Answer
Approachable Raman Solutions The Shortest Path from Problem to Answer Michael S. Bradley The world leader in serving science Thermo Scientific Raman Spectroscopy: Discover. Solve. Assure. Raman Spectroscopy
More informationAdvanced Research Raman System Raman Spectroscopy Systems
T600 Advanced Research Raman System Raman Spectroscopy Systems T600 Advanced Research Raman System T600 Triple stage Raman Spectrometer: The only solution for unprecedented stability and performance! Robust
More informationKeysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.
Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer Application Note Introduction Excellent impedance measurement accuracy and repeatability
More informationCorporate Invention Board
Corporate Invention Board Characterizing the nature and extent of technological globalisation Antoine SCHOEN Univ Paris-Est, LATTS, ESIEE, IFRIS The Output of R&D activities: Harnessing the Power of Patents
More informationUWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer
UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer Application Note Minimize cost of test with the 20 GHz ENA s high performance and fast measurement speed Quickly leverage your current
More informationUVISEL. Spectroscopic Phase Modulated Ellipsometer. The Ideal Tool for Thin Film and Material Characterization
UVISEL Spectroscopic Phase Modulated Ellipsometer The Ideal Tool for Thin Film and Material Characterization High Precision Research Spectroscopic Ellipsometer The UVISEL ellipsometer offers the best combination
More informationP7500 Series Probes Tip Selection, Rework and Soldering Guide
How-to-Guide P7500 Series Probes Tip Selection, Rework and For Use with Memory Component Interposers P7500 Series Probe Tip Selection, Rework and for Use with Memory Component Interposers Introduction
More informationSimplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE
Simplifying DC-DC Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope Introduction DC-DC converters are widely used electronic components that convert
More informationMeasuring Vgs on Wide Bandgap Semiconductors APPLICATION NOTE
Measuring Vgs on Wide Bandgap Semiconductors This application note focuses on accurate high-side V GS measurements using the IsoVu measurement system. The measurements described in this application note
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Z-Active Differential Probe Family P7313 P7380A P7360A P7340A Data Sheet Features & Benefits Signal Fidelity >12.5 GHz
More informationDPO7OE1 33 GHz Optical Probe
DPO7OE1 33 GHz Optical Probe Features and benefits Accurate Optical Reference Receiver (ORR) filters for 25 GBd, 26 GBd, and 28 GBd optical networking standards ensure highest measurement accuracy and
More informationLeica DVM - 3D Visualisation. Vertical resolution in the balance between numerical aperture and depth of field. Living up to Life
Leica DVM - 3D Visualisation Vertical resolution in the balance between numerical aperture and depth of field Living up to Life Vertical resolution in the balance between numerical aperture and depth of
More informationKeysight Technologies MATLAB Data Analysis Software Packages
Keysight Technologies MATLAB Data Analysis Software Packages For Keysight Oscilloscopes Data Sheet 02 Keysight MATLAB Data Analysis Software Packages - Data Sheet Enhance your InfiniiVision or Infiniium
More informationKeysight Technologies MEMS On-wafer Evaluation in Mass Production
Keysight Technologies MEMS On-wafer Evaluation in Mass Production Testing at the Earliest Stage is the Key to Lowering Costs Application Note Introduction Recently, various devices using MEMS technology
More informationNRS-5000/7000. Laser Raman Spectrometer
NRS-5000/7000 Laser Raman Spectrometer The New NRS-5000/7000 Dispersive Laser Raman NRS-5500/5600 High-End Model NRS-7500/7600 Flagship Model The performance and functions expected on a micro-raman spectrometer
More informationKeysight Technologies Scanning Microwave Microscope Mode. Application Note
Keysight Technologies Scanning Microwave Microscope Mode Application Note Introduction Measuring electromagnetic properties of materials can provide insight into applications in many areas of science and
More informationParameter Selection and Spectral Optimization Using the RamanStation 400
Parameter Selection and Spectral Optimization Using the RamanStation 400 RAMAN SPECTROSCOPY A P P L I C A T I O N N O T E In modern dispersive Raman spectroscopy, good quality spectra can be obtained from
More informationAdvanced Statistical Analysis Using Waveform Database Acquisition
Advanced Statistical Analysis Using Waveform Database Acquisition This brief provides an overview of the specialized acquisition capabilites of the TDS/CSA7000B, TDS6000 and TDS5000 Waveform Database acquisition
More informationTreasury and Trade Solutions Citi Commercial Cards. A History of Achievement. A Future of Innovation. May 19-21, 2014
Treasury and Trade Solutions Citi Commercial Cards A History of Achievement. A Future of Innovation. May 19-21, 2014 Communicating and Marketing Your Program Internally Pauline Smith Carla Vitaliano, The
More informationKeysight Technologies Enhancing Measurement Performance for the Testing of Wideband MIMO Signals
Keysight Technologies Enhancing Measurement Performance for the Testing of Wideband MIMO Signals White Paper How to generate and apply magnitude and phase corrections for multichannel baseband IQ measurements
More information100GBASE-KR4/CR4 & CAUI-4 Compliance and Characterization Solution
100GBASE-KR4/CR4 & CAUI-4 Compliance and Characterization Solution This application package is designed in conjunction with the performance levels offered by a 50 GHz 70KSX instrument pair. The 100G-TXE
More informationTektronix Logic Analyzer Probes P6800/P6900 Series Datasheet
Tektronix Logic Analyzer Probes P6800/P6900 Series Datasheet 6.5 V p-p dynamic range supports a broad range of logic families General-purpose probing allows flexible attachment to industrystandard connections
More informationAgilent MXG Signal Generators
Agilent MXG Signal Generators N5161A MXG ATE Analog N5162A MXG ATE Vector N5181A MXG Analog N5182A MXG Vector Configuration Guide This guide is to assist in the ordering process for the MXG analog and
More informationKeysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A
Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A B2961A/B2962A 6.5 Digit Low Noise Power Source Application Note Introduction Resistance measurement is one of the most
More informationKeysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.
Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters Application Note 02 Keysight Understanding the Importance of Maximum Power Point Tracking
More informationKeysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.
Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter Application Note Introduction Highly accurate and repeatable measurements DC bias function
More informationAgilent NFA Noise Figure Analyzer
Agilent NFA Noise Figure Analyzer Configuration Guide Dedicated Noise Figure Analyzer Hard specifications to 26.5 GHz Works with N4000A SNS or 346 Series noise sources Noise figure measurements to 110
More informationApplications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region
Feature Article JY Division I nformation Optical Spectroscopy Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region Raymond Pini, Salvatore Atzeni Abstract Multichannel
More informationThe Most Efficient SMT Solder Paste Stencil Cutter Available LPKF StencilLaser G 6080
The Most Efficient SMT Solder Paste Stencil Cutter Available LPKF StencilLaser G 6080 Improved Quality No Chiller Needed In Process Inspection Specific Configurations Stencils up to 1 600 mm long See for
More informationTriVista. Universal Raman Solution
TriVista Universal Raman Solution Why choose the Princeton Instruments/Acton TriVista? Overview Raman Spectroscopy systems can be derived from several dispersive components depending on the level of performance
More informationKeysight Technologies N9310A RF Signal Generator
Keysight Technologies N9310A RF Signal Generator 02 Keysight N9310A RF Signal Generator Brochure All the capability and reliability of a Keysight instrument you need at a price you ve always wanted Reliable
More informationPassive High Voltage Probes P5100 P5102 P5120 P6015A
P5120. P5100 High Voltage Probe The P5100 is a low-input capacitance High Voltage Probe (2.5 kv) designed for higher frequency applications. The probe can be compensated to match plug-ins and oscilloscopes
More informationTrouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL
Trouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL TUTORIAL With the Internet of Things comes the Interference of Things Over the past decade there has been a dramatic increase in the
More informationIsolation Addresses Common Sources of Differential Measurement Error
By Tom Neville A typical measurement system includes an oscilloscope and an oscilloscope probe that provides the connection between the device under test (DUT) and the oscilloscope. Probe selection is
More information